pressure reducing valves - · pdf filethe right solution is the installation of a pressure...

8
PRESSURE REDUCING VALVES

Upload: buingoc

Post on 31-Jan-2018

232 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PRESSURE REDUCING VALVES -  · PDF fileThe right solution is the installation of a pressure reducing valve on each floor (in very high buildings, this equipment is

PRESSURE REDUCING VALVES

Page 2: PRESSURE REDUCING VALVES -  · PDF fileThe right solution is the installation of a pressure reducing valve on each floor (in very high buildings, this equipment is

SOCLA, MANUFACTURER...

PRESSURE

Robotized assembling machines guaran-tee a constant level of quality.

Assembling

The best modern CAD/CAM tools to mas-ter the complex shaped products and guarantee robustness and hydraulic per-formances.

Conception, innovation

Pressure reducing valve machining

Automatic machine for pressure reducing valve assembling

Technical department

Machines which guarantee good-quality and precision products and run through machining without dismantling and return.

Machining

The equipments are individually tested and adjusted.

Engineering test

Testing bed

Pressure reducing valves

Page 3: PRESSURE REDUCING VALVES -  · PDF fileThe right solution is the installation of a pressure reducing valve on each floor (in very high buildings, this equipment is

C 301

I

AC 101

C

L

B

M

E

F

D

P

O

C 101C 301

K

J

S

R

Q

H

G

C 101

C 101

C 901

C 301

C 301

C 301

C 201 PP

C 306

N

1

P

C 108

C 401

C 101C 301

C 301

I

AC 101

C

L

B

M

E

F

D

P

O

C 101C 301

K

J

S

R

Q

H

G

C 101

C 101

C 901

C 301

C 301

C 301

C 201 PP

C 306

N

1

P

C 108

C 401

C 101C 301

C 301

I

AC 101

C

L

B

M

E

F

D

P

O

C 101C 301

K

J

S

R

Q

H

G

C 101

C 101

C 901

C 301

C 301

C 301

C 201 PP

C 306

N

1

P

C 108

C 401

C 101C 301

C 301

I

AC 101

C

L

B

M

E

F

D

P

O

C 101C 301

K

J

S

R

Q

H

G

C 101

C 101

C 901

C 301

C 301

C 301

C 201 PP

C 306

N

1

P

C 108

C 401

C 101C 301

tt

tt

A COMPLETE RANGE ADAPTED TO ALL NEEDS IN PRESSURE REDUCING VALVES.

Here are some examples...

REDUCER

Miscellaneous industrial applications

Protection of the whole installation (hot and cold water supply systems).The pressure reducing valve is installed at the entrance of the main supply.

Private houses

Apartments protection The right solution is the installation of a pressure reducing valve on each floor (in very high buildings, this equipment is not necessary on the most high floors if the pressure is equal or under 3 bar).

Collective houses

Sanitary appliance and showers,Machines and work stations,Central heating systems,Compressed air lines.

Very low pressure for agriculture, irrigation

A specific range specially adapted to low pressure.

A LARGE AND COMPLETE RANGE

Page 4: PRESSURE REDUCING VALVES -  · PDF fileThe right solution is the installation of a pressure reducing valve on each floor (in very high buildings, this equipment is

• 80°C max.ACS

NORVEGEByggForsk 0689

+

••••

THE PERFORMANCES...

Water pressure reducing and regulating are both used.

We use the term «reducing» because it is standard terminology, but our valves arereally regulators.

Because they control the downstream pressure whether there is a flow or not. The downs-tream cannot vary more than 7 or 8% of the up stream pressure when there is no flow and only by the head loss when there is flow.

A low value shows the hydraulic quality of agood regulator.

STANDARDS & AGREEMENTS MAIN PERMISSIBLEMEDIUMS

PRESSURE

PERMISSIBLETEMPERATURES

NOMINAL DIAMETERS

Upstream pressure 16 and 25 bardepending on the product.Downstream pressure from 0.5 to 7 bar with compensatingspring

From diameter 10 mmto diameter 100 mm

FRANCENF EN 1567

Hot and cold water

Compressed air

Natural gas

Domestic fuel

NF (types 11 and 9)

European StandardNF EN 1567

(Attestation de conformité sanitaire)

Pressure reducing valves

Pressurereducing valve

or Pressure

regulator valves ?

• Any position installation• Scale and dirt proof• No maintenance• No filter• Excellent acoustic and hydraulic performances• Upstream pressure up to 25 bar• Precise and permanent setting• All type of connections• A single model hot and cold water• Bronze casing

Page 5: PRESSURE REDUCING VALVES -  · PDF fileThe right solution is the installation of a pressure reducing valve on each floor (in very high buildings, this equipment is

FLOW downstream :Outlet pressure drops. Spring pushes against the diaphragm and disc and opens the valve.The upstream pressure becomes for example 2,5 bar compared to 3bar at the beginning. The 0,5 bar difference is the head loss

NO FLOW downstream :Outlet pressure goes up again. When it corresponds to the setting, diaphragms and disc, push against the spring and thus close the valve.

INSTALLATION

ADJUSTMENT

In domestic water supply, the pressure reducing valves are fitted just after the water meter and thus protect the whole installation.If there is a frost risk, they should be protected.

They can be fitted in any position but in all cases the direction of flow must be correct as shown by the arrow engraved on the valve body.

To increase the pressure

To decrease the pressure

The water pressure reducing valves are always set under “no flow”,i.e. with all downstream taps or flow closed. The pressure gaugethus shows a “static” pressure.

To increase outlet pressure :• Tighten adjusting screw (clockwise)

To decrease outlet pressure :• Slacken the adjusting screw (anti-clockwise).• Release pressure by briefly opening a tap on outlet side. Close taps.• Then retighten adjusting screw to obtain required pressure. It is normal

to see a DOWNSTREAM pressure drop during flow downstream : this is the pressure drop.

OPERATING PRINCIPLE

The outlet pressure acts on the bottom face of the diaphragm, compressing the spring when it exceeds the pre-set value and thus closing the valve. As long as no water is drawn off the downstream side (no-flow condition), the outlet pressure is thus kept at the pre-set value.

When water is drawn off the downstream side, the outlet pressure decreases and the spring pushes against the diaphragm, opening the valve. Under pro-longed flow conditions, a self-damping effect occurs in the valve opening instead a series of jerky opening and closing movements.

Pressure reducing valves

Stainless Steel

Page 6: PRESSURE REDUCING VALVES -  · PDF fileThe right solution is the installation of a pressure reducing valve on each floor (in very high buildings, this equipment is

(*)

A COMPLETE RANGEOF WATER PRESSURE REDUCING VALVES

> Flats and houses individual water supply

> Water supply of house blocks, collective housing

> Protection of individual device, water heater

> Flats and houses individual water supply

> Flats and houses individual water supply

Type 11male/male

Type 11BIS female/female

From DN 15 to 50 mm (except type 11EP)Downstream setting : 1 bar to 5.5 barSupplied preset at 3 barReference RC (compensating spring) for downstream pressure setting from 0.5 bar to 1 bar.11 EP : female union nut - male11 DO : removable fittings

Type 9male/male

Type 9BIS female/female

From DN 15 to 25 mmNon adjustable set at 3 bar.

Type 11BIS RCBPmale/male

DN 20 mmDownstream setting : from 0.1 to 0.6 bar

Type 5 SPmale/female

DN 20 mmDownstream setting : from 1 to 5.5 bar.Setting : supplied pre-set downstream

at 3 bar.Inlet male - Outlet insert nut.

Type 7BIS female/female

Type 7EPfemale/male

Type 7SPmale/female

Downstream setting : from 1 to 5.5 bar.Setting : supplied preset at 3 bar 7 BIS : double female ends7 EP : union nuts - male7 SP : male - union nuts Multi 7(*): delivered with 3 nuts allowing 16

different connecting possibilities

Type 10male/male

Type 10BIS female/female

Type 10TER with flanges

From DN 32 mm : 2 sides pressure cocks for pressure gauges. Downstream setting : 1 bar to 7 bar.Adjustable : supplied unset.RC reference (compensating spring) for downstream pressure setting from 0,5 bar to 1 bar.

Special for sea water(consult us)

> Very low pressure agriculture, irrigation, laboratory

1 pressure gauge connection at the bottom 2 pressure gauge connection on the side

1 pressure gauge connection at the bottom

A pressure gauge connection and drain at the bottom

1 drain connection at the bottom

2 sides pressure cocks for pressure gauges DN32 mm

tt

tt

tt

Type 11EPfemale/male

Type Multi 7Multi-connections

Pressure reducing valves

Type 11 DOmale/male

Type 10BIS BZ female/female

Page 7: PRESSURE REDUCING VALVES -  · PDF fileThe right solution is the installation of a pressure reducing valve on each floor (in very high buildings, this equipment is

THE RANGE OF ACCESSORIES

> Pressure control

Type 487Pressure gauge nipple

• Plug 1/4”. • Brass up to 1” included - bronze upper sizes.

> Flow meter

Type 777

• Direct reading indicating instant flow rate, up to 25 l/min on domestic taps• Exclusive patent - ABS material.

> Gauges

Type 212ADPRESSADE

• With central needle. • Male thread 8/13 (1/4”).• Rubber cap.• Exclusive patent .

Gauges must never stay continuously under pressure. They must be protected by a stop valve.

Type 2212B

• Central needle. • Male thread 8/13 (1/4”). • Vertical.• Painted steel casing DN50.

Type 213BIS

• Male thread 8/13 (1/4”). • Female output.

> Stop Valve

The 487 nipple can be fixed for all pressure reducing valves (outlet or inlet) except flanges. Possibility of customisation (colour and

marking) depending on quantities.

For quick inspection of pressure on any ori-fice from 8 to 20 mm.

For more detail concerning our whole range, do not hesitate to ask for our technical data sheets

or to go on our internet site : www.socla.com.

Type 212Gwith glycerine bath Stainless steel casing DN 60 mm - Vertical

Type 212BISwith central needle Brass casing DN 50 mm vertical

Type 3212Bwith central needle Steel casing DN 50 mmHorizontal

Type 212BPwith central needle Steel casing DN 60 mm Vertical

Pressure reducing valves

Discover our technical data sheets

Some others types of gauges can be proposed, as follow :

• Control and maintain the downstream pressure at an adjustable reduced value, whether there is a flow or not.

• Keep an outlet pressure at a constant value, even with variation of the upstream pressure (the down-stream pressure cannot vary more than 10 % of the variation of the upstream pressure, according to the Standard).

• No maintenance required, not affected by scale or dirt.• Can be installed in any position.• Guarantee a high flow rate at a constant outlet

pressure because of low head loss.• Work as pressure reducing valve (standard terminology)

as well as “regulator” and as “pressure regulating valve” (when applies for gas).

• Adjustable : supplied pre-set at 3 bar.• 1/4” pressure gauge connection and drain at the

bottom of the casing.• Also available with compensating spring : type 11 RC, for

lower downstream pressure.

Technical data sheet

Type 11 and 11RC Pressure reducing valve

Applications and special features

• Connection : male/male (BSP)• Downstream pressure gauge connection : 1/4”• Permissible operating pressure PFA - water : See table• Maximum permissible pressure PS - other mediums :

See table • θ : Mini. -10 °C Maxi. in permanent service: 80 °C (40°C domestic fuel oil)• Mediums : water, air and neutral gas , domestic fuel oil.• Approvals : ACS - : Type 11 DN 15 - 25 : (11bis DN 15 - 20) • International construction Standards : Pressure reducing valves EN 1567 Thread connection NF EN ISO 228

Technical description

uk11_11rc - Updated : 25/09/2009 1

1/2 15 25 25 25 X 25 3.3 149B7068

3/4 20 25 25 25 X 25 3.3 149B7069

Type RC

L1, L2, G1 and G2 correspond to liquids/gas classified into degree of danger according to the Pressure Equipment Directive (PED).The article 3.3 applies to equipments with no CE marking.

BA

E

D

COverall dimensionsDN

D A B C E Weight

” mm mm mm mm mm kg

15 1/2 15/21 31 60 59 85 0,7

20 3/4 20/27 32 75 73 76,5 0,9

25 1’’ 26/34 40 102 94 122 2

32 1’’1/4 33/42 51 179 104 132 3,9

40 1’’1/2 40/49 46 185 104 132 5

50 2’’ 50/60 54 194 104 146 5,3

DN PFA (bar)

PS (bar) Cat. References Vvs-nr“ mm L1 L2 G1 G2

1/2 15 25 25 25 X 25 3.3 149B7054

3/4 20 25 25 25 X 25 3.3 149B7055

1’’ 25 25 25 25 X 25 3.3 149B7489

1’’1/4 32 25 25 25 X 25 3.3 149B7548

1’’1/2 40 25 25 25 X 25 3.3 149B7567

2’’ 50 25 25 25 X 25 3.3 149B7565

Page 8: PRESSURE REDUCING VALVES -  · PDF fileThe right solution is the installation of a pressure reducing valve on each floor (in very high buildings, this equipment is

Shut Off

Protection

Non return

Regulation

Socla sas365 rue du Lieutenant Putier

71530 Virey-Le-GrandBP10273 - 71107 Chalon S/Saône Cedex

Tel. +33 3 85 97 42 42 - Fax +33 3 85 97 97 42e-mail:[email protected]

http://www.socla.com

Working hoursMonday to Thursday 8 a.m. to 5.30 p.m.

Friday 8 a.m. to 1.30 p.m.Socla - Desbordes - Sylax 2698

952

- 12

/201

1