pressure measurement section#1-intro pressure book_revdvm
DESCRIPTION
Pressure Transmitters Are the Most Versatile Measurement Instruments Level in Distillation Column Pressure in Vessel Flow in Pipeline Section#1-Intro Pressure Book_revDVmTRANSCRIPT
Pressure MeasurementPressure Measurement
[File Name or Event]Emerson Confidential27-Jun-01, Slide 2
Level inDistillation
Column
Flow inPipeline
Pressurein
Vessel
Pressure Transmitters Are the Most Pressure Transmitters Are the Most Versatile Measurement Instruments Versatile Measurement Instruments
[File Name or Event]Emerson Confidential27-Jun-01, Slide 3
Pressure Transmitters Are Used to Pressure Transmitters Are Used to Measure Flow, Level, and Pressure Measure Flow, Level, and Pressure
Flow
Flow = Q = k DP
Level
Level = Ht. x SG
Pressure: DP, GP, AP
Pressure
[File Name or Event]Emerson Confidential27-Jun-01, Slide 4
Pric
e
Customer Value/Capability
Industry Specific
Tiered Offering
1151/2088
3051C/T
3051S
3095
Rosemount’s Comprehensive Pressure Rosemount’s Comprehensive Pressure Offering Covers All Process ApplicationsOffering Covers All Process Applications
Complete Point Solutions
Manifolds
DP Level
DP Flow
4500 – Life Sciences
4600 – Oil & Gas
1810 – Pulp & Paper
951 - HVAC
Company ConfidentialSlide 4
[File Name or Event]Emerson Confidential27-Jun-01, Slide 5
Rosemount Pressure has Demonstrated Rosemount Pressure has Demonstrated Continuous Industry LeadershipContinuous Industry Leadership
1969 1988 1994 2002
Model 3051
Rugged capacitance sensors& transmitter packaging
Modular construction Dual compartment housings Over 5 million units sold
Model 1151
CoplanarTM Design Platform ASIC-Surface Mount Technology Integral Manifolds, Flow Elements Over 2 million units sold
Model 3095 3051S Series
MultivariableTM DP, P, & T Dynamically Compensated
Mass Flow Full AGA & ISO Flow
Calculations
Industry FirstsCoplanarCapacitance
Sensors
Multivariable
DP MassFlow
SmartLow Power
IntegralManifolds
5 & 10 YearStability
TotalPerformance
Dual CompartmentModular Packaging
TrulyScalable
Architecture
Scalable Platform New Measurement
Practices 2X Performance 2X Reliability
[File Name or Event]Emerson Confidential27-Jun-01, Slide 6
Pressure Solutions StrategyPressure Solutions Strategy2) Establish 3051S as the Premier Pressure Offering2) Establish 3051S as the Premier Pressure Offering Redefine Customer Value with 3051S Scalability Position the 3051S as “No Equal” Sell Application Based Functionality Command a Price Premium!
Analog
1970 1980 1990 2000 2010
Cus
tom
er V
alue
Capability Over Time
Smart (Performance)
IntegratedSolutions
Scalable
PowersPlantWeb
AdvancedDiagnostics
InnovativeTechnology
Company ConfidentialSlide 6
[File Name or Event]Emerson Confidential27-Jun-01, Slide 7
Introduction Section ReviewIntroduction Section Review2. What are the 3 primary process variables pressure
transmitters are used for?
[File Name or Event]Emerson Confidential27-Jun-01, Slide 8
Rosemount 1151
1151 Pressure Transmitter1151 Pressure Transmitter
[File Name or Event]Emerson Confidential27-Jun-01, Slide 9
Coplanar Benefits• Compact, Rugged, Flexible Design • Improved Performance• Direct Process Mounting Capability • Increased Functionality • Reduced Installation Costs • Creates Platform to Build Upon• Single Flange, Reduced Process Seals
Coplanar PlatformCoplanar Platform
[File Name or Event]Emerson Confidential27-Jun-01, Slide 10
Coplanar InterfaceCoplanar Interface
Flanges
Manifolds LevelPrimaries
[File Name or Event]Emerson Confidential27-Jun-01, Slide 11
ManifoldManifold
[File Name or Event]Emerson Confidential27-Jun-01, Slide 12
Rosemount 2088 OfferingsRosemount 2088 Offerings 2088 Absolute & Gauge Pressure Transmitters
– 4-20mA Smart Output, Low Power– 0.1% Accuracy, 0.075% option– 20:1 Rangedown– SST/Hastelloy C-276 Materials
[File Name or Event]Emerson Confidential27-Jun-01, Slide 13
Rosemount 1151 OfferingRosemount 1151 Offering Installed base - 5 million transmitters 1151 for DP/GP/AP Applications
– Both SMART and Analog outputs– 0.075% Accuracy– 50:1 Rangedown– 0.1% stability for 2 years– SST, Hastelloy C-276, Tantalum offerings
1151LT for level applications
[File Name or Event]Emerson Confidential27-Jun-01, Slide 14
Installed base - 3 million transmitters
3051C “Coplanar” for DP/GP/AP applications
3051T “In-line” for GP/AP applications
±0.065% Accuracy, 0.04% option 100:1 Rangeability
Rosemount 3051C and 3051TRosemount 3051C and 3051T
[File Name or Event]Emerson Confidential27-Jun-01, Slide 15
Additional 3051 OfferingsAdditional 3051 Offerings
3051L Level transmitter – Variety of fill fluid options– Welded design improves reliability– Flush and extended diaphragms
[File Name or Event]Emerson Confidential27-Jun-01, Slide 16
Mounting Brackets & Bolts (cont.)Mounting Brackets & Bolts (cont.)
Pipe Mount
Panel Mount
When would a mounting bracket be unnecessary?