pressure drop evaluation along pipelines

26
Pressure drop evaluation along pipelines The simplest way to convey a fluid, in a contained system from Point A to Point B, is by means of a conduit or pipe (Fig. 1). Fig. 1—Fluid-flow system (courtesy of AMEC Paragon). Contents 1 Piping design 2 Bernoulli equation 3 Reynolds number and Moody friction factor 4 Pressure drop for liquid flow o 4.1 General equation o 4.2 Hazen Williams equation 5 Pressure drop for gas flow o 5.1 General equation o 5.2 Simplified equation 5.2.1 Weymouth equation 5.2.2 Panhandle equation 5.2.3 Spitzglass equation o 5.3 Application of the formulas 5.3.1 Simplified gas formula 5.3.2 Weymouth equation

Upload: peweaje

Post on 17-Jul-2016

23 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Pressure Drop Evaluation Along Pipelines

Pressure drop evaluation along pipelinesThe simplest way to convey a fluid, in a contained system from Point A to Point B, is by means of a conduit or pipe (Fig. 1).

Fig. 1—Fluid-flow system (courtesy of AMEC Paragon).

Contents 1 Piping design 2 Bernoulli equation 3 Reynolds number and Moody friction factor 4 Pressure drop for liquid flow

o 4.1 General equationo 4.2 Hazen Williams equation

5 Pressure drop for gas flow o 5.1 General equationo 5.2 Simplified equation

5.2.1 Weymouth equation 5.2.2 Panhandle equation 5.2.3 Spitzglass equation

o 5.3 Application of the formulas 5.3.1 Simplified gas formula 5.3.2 Weymouth equation 5.3.3 Panhandle equation 5.3.4 Spitzglass equation

6 Multiphase flow o 6.1 Flow regimes

6.1.1 Bubble 6.1.2 Slug flow

Page 2: Pressure Drop Evaluation Along Pipelines

6.1.3 Transition flow 6.1.4 Annular mist flow

o 6.2 Two phase pressure dropo 6.3 Simplified friction pressure drop approximation for two phase flowo 6.4 Pressure Drop Because of Changes in Elevation

7 Pressure drop caused by valves and fittings o 7.1 Resistance coefficientso 7.2 Flow coefficientso 7.3 Equivalent lengths

8 Nomenclature 9 References 10 Noteworthy papers in OnePetro 11 External links 12 See also

Piping designThe minimum basic parameters that are required to design the piping system include, but are not limited to, the following.

The characteristics and physical properties of the fluid. The desired mass-flow rate (or volume) of the fluid to be transported. The pressure, temperature, and elevation at Point A. The pressure, temperature, and elevation at Point B. The distance between Point A and Point B (or length the fluid must travel) and

equivalent length (pressure losses) introduced by valves and fittings.

These basic parameters are needed to design a piping system. Assuming steady-state flow, there are a number of equations, which are based upon the general energy equation, that can be employed to design the piping system. The variables associated with the fluid (i.e., liquid, gas, or multiphase) affect the flow. This leads to the derivation and development of equations that are applicable to a particular fluid. Although piping systems and pipeline design can get complex, the vast majority of the design problems encountered by the engineer can be solved by the standard flow equations.

Bernoulli equationThe basic equation developed to represent steady-state fluid flow is the Bernoulli equation which assumes that total mechanical energy is conserved for steady, incompressible, inviscid, isothermal flow with no heat transfer or work done. These restrictive conditions can actually be representative of many physical systems.

The equation is stated as

(Eq. 1) where

Page 3: Pressure Drop Evaluation Along Pipelines

Z = elevation head, ft, P = pressure, psi, ρ = density, lbm/ft3, V = velocity, ft/sec, g = gravitational constant, ft/sec2, and HL = head loss, ft.

Fig. 2 presents a simplified graphic illustration of the Bernoulli equation.

Fig. 2—Sketch four Bernoulli equation (courtesy of AMEC Paragon).

Darcy’s equation further expresses head loss as

(Eq. 2) and

(Eq. 3) where

HL = head loss, ft, f = Moody friction factor, dimensionless, L = pipe length, ft,

Page 4: Pressure Drop Evaluation Along Pipelines

D = pipe diameter, ft, V = velocity, ft/sec, g = gravitational constant ft/sec2, ΔP = pressure drop, psi, ρ = density, lbm/ft3, and d = pipe inside diameter, in.

Reynolds number and Moody friction factor The Reynolds number is a dimensionless parameter that is useful in characterizing the degree of turbulence in the flow regime and is needed to determine the Moody friction factor. It is expressed as

(Eq. 4) where

ρ = density, lbm/ft3, D = pipe internal diameter, ft, V = flow velocity, ft/sec, and μ = viscosity, lbm/ft-sec.

The Reynolds number for liquids can be expressed as

(Eq. 5) where

μ = viscosity, cp, d = pipe inside diameter, in., SG = specific gravity of liquid relative to water (water = 1), Ql = liquid-flow rate, B/D, and V = velocity, ft/sec.

The Reynolds number for gases can be expressed as

(Eq. 6) where

μ = viscosity, cp, d = pipe inside diameter, in., S = specific gravity of gas at standard conditions relative to air (molecular weight divided

Page 5: Pressure Drop Evaluation Along Pipelines

by 29), and Qg = gas-flow rate, MMscf/D.

The Moody friction factor, f, expressed in the previous equations, is a function of the Reynolds number and the roughness of the internal surface of the pipe and is given by Fig. 3. The Moody friction factor is impacted by the characteristic of the flow in the pipe. For laminar flow, where Re is < 2,000, there is little mixing of the flowing fluid, and the flow velocity is parabolic; the Moody friction factor is expressed as f = 64/Re. For turbulent flow, where Re > 4,000, there is complete mixing of the flow, and the flow velocity has a uniform profile; f depends on Re and the relative roughness (Є/D). The relative roughness is the ratio of absolute roughness, Є, a measure of surface imperfections to the pipe internal diameter, D. Table 9.1 lists the absolute roughness for several types of pipe materials.

Fig. 3—Friction-factor chart (courtesy of AMEC Paragon).

Table 1

If the viscosity of the liquid is unknown, Fig. 4 can be used for the viscosity of crude oil, Fig. 5 for effective viscosity of crude-oil/water mixtures, and Fig. 6 for the viscosity of natural gas. In using some of these figures, the relationship between viscosity in centistokes and viscosity in centipoise must be used

Page 6: Pressure Drop Evaluation Along Pipelines

(Eq. 7) where

γ = kinematic viscosity, centistokes, ϕ = absolute viscosity, cp, and SG = specific gravity.

Fig. 4—Standard viscosity/temperature charts for liquid petroleum products (courtesy of ASTM).

Fig. 5—Effective viscosity of an oil/water mixture (courtesy of AMEC Paragon).

Page 7: Pressure Drop Evaluation Along Pipelines

Fig. 6—Hydrocarbon-gas viscosity vs. temperature (courtesy Western Supply Co.).

Pressure drop for liquid flow

General equation

Eq. 3 can be expressed in terms of pipe inside diameter (ID) as stated next.

(Eq. 8) where

d = pipe inside diameter, in., f = Moody friction factor, dimensionless, L = length of pipe, ft, Ql = liquid flow rate, B/D, SG = specific gravity of liquid relative to water, and ΔP = pressure drop, psi (total pressure drop).

Hazen Williams equation

The Hazen-Williams equation, which is applicable only for water in turbulent flow at 60°F, expresses head loss as

(Eq. 9) where

HL = head loss because of friction, ft, L = pipe length, ft, C = friction factor constant, dimensionless (Table 2), d = pipe inside diameter, in., Ql = liquid flow rate, B/D, and gpm = liquid flow rate, gal/min.

Page 8: Pressure Drop Evaluation Along Pipelines

Table 2

Pressure drop can be calculated from

(Eq. 10)

Pressure drop for gas flow

General equation

The general equation for calculating gas flow is stated as

(Eq. 11) where

w = rate of flow, lbm/sec, g = acceleration of gravity, 32.2 ft/sec2, A = cross-sectional area of pipe, ft2, V1‘ = specific volume of gas at upstream conditions, ft3/lbm, f = friction factor, dimensionless, L = length, ft, D = diameter of the pipe, ft, P1 = upstream pressure, psia, and P2 = downstream pressure, psia.

Assumptions: no work performed, steady-state flow, and f = constant as a function of the length.

Page 9: Pressure Drop Evaluation Along Pipelines

Simplified equation

For practical pipeline purposes, Eq. 11 can be simplified to

(Eq. 12) where

P1 = upstream pressure, psia, P2 = downstream pressure, psia, S = specific gravity of gas, Qg = gas flow rate, MMscf/D, Z = compressibility factor for gas, dimensionless, T = flowing temperature, °R, f = Moody friction factor, dimensionless, d = pipe ID, in., and L = length, ft.

The compressibility factor, Z, for natural gas can be found in Fig. 7.

Fig. 7—Compressibility of low-molecular-weight natural gases (courtesy of Natl. Gas Processors Suppliers Assn.).

Three simplified derivative equations can be used to calculate gas flow in pipelines:

The Weymouth equation The Panhandle equation The Spitzglass equation

All three are effective, but the accuracy and applicability of each equation falls within certain ranges of flow and pipe diameter. The equations are stated next.

Weymouth equation

Page 10: Pressure Drop Evaluation Along Pipelines

This equation is used for high-Reynolds-number flows where the Moody friction factor is merely a function of relative roughness.

(Eq. 13) where

Qg = gas-flow rate, MMscf/D, d = pipe inside diameter, in., P1 = upstream pressure, psia, P2 = downstream pressure, psia, L = length, ft, T1 = temperature of gas at inlet, °R, S = specific gravity of gas, and Z = compressibility factor for gas, dimensionless.

Panhandle equation

This equation is used for moderate-Reynolds-number flows where the Moody friction factor is independent of relative roughness and is a function of Reynolds number to a negative power.

(Eq. 14) where

E = efficiency factor (new pipe: 1.0; good operating conditions: 0.95; average operating conditions: 0.85),

Qg = gas-flow rate, MMscf/D, d = pipe ID, in., P1 = upstream pressure, psia, P2 = downstream pressure, psia, Lm = length, miles, T1 = temperature of gas at inlet, °R, S = specific gravity of gas, and Z = compressibility factor for gas, dimensionless.

Spitzglass equation

Page 11: Pressure Drop Evaluation Along Pipelines

(Eq. 15) where

Qg = gas-flow rate, MMscf/D, ΔhW = pressure loss, inches of water, and d = pipe ID, in.

Assumptions:

f = (1+ 3.6/ d + 0.03 d ) (1/100), T = 520°R, P1 = 15 psia, Z = 1.0, and ΔP = < 10% of P 1 .

Application of the formulas

As previously discussed, there are certain conditions under which the various formulas are more applicable. A general guideline for application of the formulas is given next.

Simplified gas formula

This formula is recommended for most general-use flow applications.

Weymouth equation

The Weymouth equation is recommended for smaller-diameter pipe (generally, 12 in. and less). It is also recommended for shorter lengths of segments ( < 20 miles) within production batteries and for branch gathering lines, medium- to high-pressure (+/–100 psig to > 1,000 psig) applications, and a high Reynolds number.

Panhandle equation

This equation is recommended for larger-diameter pipe (12-in. diameter and greater). It is also recommended for long runs of pipe ( > 20 miles) such as cross-country transmission pipelines and for moderate Reynolds numbers.

Spitzglass equation

Page 12: Pressure Drop Evaluation Along Pipelines

The Spitzglass equation is recommended for low-pressure vent lines < 12 in. in diameter (ΔP < 10% of P1).

The petroleum engineer will find that the general gas equation and the Weymouth equation are very useful. The Weymouth equation is ideal for designing branch laterals and trunk lines in field gas-gathering systems.

Multiphase flow

Flow regimes

Fluid from the wellbore to the first piece of production equipment (separator) is generally two-phase liquid/gas flow.

The characteristics of horizontal, multiphase flow regimes are shown in Fig. 8. They can be described as follows:

Bubble: Occurs at very low gas/liquid ratios where the gas forms bubbles that rise to the top of the pipe.

Plug: Occurs at higher gas/liquid ratios where the gas bubbles form moderate-sized plugs.

Stratified: As the gas/liquid ratios increase, plugs become longer until the gas and liquid flow in separate layers.

Wavy: As the gas/liquid ratios increase further, the energy of the flowing gas stream causes waves in the flowing liquid.

Slug: As the gas/liquid ratios continue to increase, the wave heights of the liquid increase until the crests contact the top of the pipe, creating liquid slugs.

Spray: At extremely high gas/liquid ratios, the liquid is dispersed into the flowing-gas stream.

Fig. 8—Two-phase-flow patterns in horizontal flow (courtesy of AMEC Paragon).

Fig. 9[1] shows the various flow regimes that could be expected in horizontal flow as a

Page 13: Pressure Drop Evaluation Along Pipelines

function of the superficial velocities of gas and liquid flow. Superficial velocity is the velocity that would exist if the other phase was not present.

Fig. 9—Horizontal multiphase-flow map (after Griffith).[1]

The multiphase flow in vertical and inclined pipe behaves somewhat differently from multiphase flow in horizontal pipe. The characteristics of the vertical flow regimes are shown in Fig. 10 and are described next.

Page 14: Pressure Drop Evaluation Along Pipelines

Fig. 10—Two-phase-flow patterns in vertical flow (courtesy of AMEC Paragon).

Bubble

Where the gas/liquid ratios are small, the gas is present in the liquid in small, variable-diameter, randomly distributed bubbles. The liquid moves at a fairly uniform velocity while the bubbles move up through the liquid at differing velocities, which are dictated by the size of the bubbles. Except for the total composite-fluid density, the bubbles have little effect on the pressure gradient.

Slug flow

As the gas/liquid ratios continue to increase, the wave heights of the liquid increase until the crests contact the top of the pipe, creating liquid slugs.

Transition flow

The fluid changes from a continuous liquid phase to a continuous gas phase. The liquid slugs virtually disappear and are entrained in the gas phase. The effects of the liquid are still significant, but the effects of the gas phase are predominant.

Annular mist flow

The gas phase is continuous, and the bulk of the liquid is entrained within the gas. The liquid wets the pipe wall, but the effects of the liquid are minimal as the gas phase becomes the controlling factor. Fig. 11[2] shows the various flow regimes that could be expected in vertical flow as a function of the superficial velocities of gas and liquid flow.

Page 15: Pressure Drop Evaluation Along Pipelines

Fig. 11—Vertical-multiphase-flow map (after Taitel et al.).[2]

Two phase pressure drop

The calculation of pressure drop in two-phase flow is very complex and is based on empirical relationships to take into account the phase changes that occur because of pressure and temperature changes along the flow, the relative velocities of the phases, and complex effects of elevation changes. Table 3 lists several commercial programs that are available to model pressure drop. Because all are based to some extent on empirical relations, they are limited in accuracy to the data sets from which the relations were designed. It is not unusual for measured pressure drops in the field to differ by ± 20% from those calculated by any of these models.

Table 3

Simplified friction pressure drop approximation for two phase flow

Eq. 16 provides an approximate solution for friction pressure drop in two-phase-flow problems that meet the assumptions stated.

(Eq. 16) where

ΔP = friction pressure drop, psi,

Page 16: Pressure Drop Evaluation Along Pipelines

f = Moody friction factor, dimensionless, L = length, ft, W = rate of flow of mixture, lbm/hr, ρM = density of the mixture, lbm/ft3, and d = pipe ID, in.

The formula for rate of mixture flow is

(Eq. 17) where

Qg = gas-flow rate, MMscf/D, QL = liquid flow rate, B/D, S = specific gravity of gas at standard conditions, lbm/ft3 (air = 1), and SG = specific gravity of liquid, relative to water, lbm/ft3.

The density of the mixture is given by

(Eq. 18) where

P = operating pressure, psia, R = gas/liquid ratio, ft3/bbl, T = operating temperature, °R, SG = specific gravity of liquid, relative to water, lbm/ft3, S = specific gravity of gas at standard conditions, lbm/ft3 (air = 1), and Z = gas compressibility factor, dimensionless.

The formula is applicable if the following conditions are met:

ΔP is less than 10% of the inlet pressure. Bubble or mist exists. There are no elevation changes. There is no irreversible energy transfer between phases.

Pressure Drop Because of Changes in Elevation

There are several notable characteristics associated with pressure drop because of elevation changes in two-phase flow. The flow characteristics associated with the elevation changes include:

Page 17: Pressure Drop Evaluation Along Pipelines

In downhill lines, flow becomes stratified as liquid flows faster than gas. The depth of the liquid layer adjusts to the static pressure head and is equal to the

friction pressure drop. There is no pressure recovery in the downhill line. In low gas/liquid flow, the flow in uphill segments can be liquid "full" at low flow

rates. Thus, at low flow rates, the total pressure drop is the sum of the pressure drops for all of the uphill runs.

With increased gas flow, the total pressure drop may decrease as liquid is removed from uphill segments.

The pressure drop at low flow rates associated with an uphill elevation change may be approximated with Eq. 19.

(Eq. 19) where

ΔPZ = pressure drop because of elevation increase in the segment, psi, SG = specific gravity of the liquid in the segment, relative to water, and ΔZ = increase in elevation for segment, ft.

The total pressure drop can then be approximated by the sum of the pressure drops for each uphill segment.

Pressure drop caused by valves and fittingsOne of the most important parameters affecting pressure drop in piping systems is pressure loss in the fittings and valves, which is incorporated in the system. For piping systems within production facilities, the pressure drop through fittings and valves can be much greater than that through the straight run of pipe itself. In long pipeline systems, the pressure drop through fittings and valves can often be ignored.

Resistance coefficients

The head loss in valves and fittings can be calculated with resistance coefficients as

(Eq. 20) where

HL = head loss, ft, Kr = resistance coefficient, dimensionless, D = pipe ID, ft, and V = velocity, ft/sec.

Page 18: Pressure Drop Evaluation Along Pipelines

The total head loss is the sum of all Kr V2/2g.

The resistance coefficients Kr for individual valves and fittings are found in tabular form in a number of industry publications. Most manufacturers publish tabular data for all sizes and configurations of their products. One of the best sources of data is the Crane Flow of Fluids, technical paper No. 410. [3] The Natural Gas Processors Suppliers Assn. (NGPSA) Engineering Data Book[4] and Ingersoll-Rand’s Cameron Hydraulic Data Book[5] are also good sources of references for the information. Some examples of resistance coefficients are listed in Tables 4 and 5.

Table 4

Table 5

Table 5 (Cont'd)

Page 19: Pressure Drop Evaluation Along Pipelines

Table 5 (Cont'd)

Table 5 (Cont'd)

Flow coefficients

The flow coefficient for liquids, CV, is determined experimentally for each valve or fitting as the flow of water, in gal/min at 60°F for a pressure drop of 1 psi through the fitting. The relationship between flow and resistance coefficients can be expressed as

(Eq. 21) In any fitting or valve with a known CV, the pressure drop can be calculated for different conditions of flow and liquid properties with Eq. 22.

(Eq. 22) where

QL = liquid-flow rate, B/D, and SG = liquid specific gravity relative to water.

Page 20: Pressure Drop Evaluation Along Pipelines

Again, the CV is published for most valves and fittings and can be found in Crane Flow of Fluids,[3] Engineering Data Book,[4] Cameron Hydraulic Data Book,[5] as well as the manufacturer’s technical data.

Equivalent lengths

The head loss associated with valves and fittings can also be calculated by considering equivalent "lengths" of pipe segments for each valve and fitting. In other words, the calculated head loss caused by fluid passing through a gate valve is expressed as an additional length of pipe that is added to the actual length of pipe in calculating pressure drop.

All of the equivalent lengths caused by the valves and fittings within a pipe segment would be added together to compute the pressure drop for the pipe segment. The equivalent length, Le, can be determined from the resistance coefficient, Kr, and the flow coefficient, CV, using the formulas given next.

(Eq. 23)

(Eq. 24) and

(Eq. 25) where

Kr = resistance coefficient, dimensionless, D = diameter of the pipe, ft, f = Moody friction factor, dimensionless, d = pipe ID, in., and CV = flow coefficient for liquids, dimensionless.

Table 6 shows equivalent lengths of pipe for a variety of valves and fittings for a number of standard pipe sizes.

Page 21: Pressure Drop Evaluation Along Pipelines

Table 6

Nomenclature

Z = elevation head, ft, P = pressure, psi, ρ = density, lbm/ft3, V = velocity, ft/sec, g = gravitational constant, ft/sec2, HL = head loss, ft. f = Moody friction factor, dimensionless, L = pipe length, ft, D = pipe diameter, ft, ΔP = pressure drop, psi, μ = viscosity, lbm/ft-sec. SG = specific gravity of liquid relative to water (water = 1), Ql = liquid-flow rate, B/D,

S = specific gravity of gas at standard conditions relative to air (molecular weight divided by 29),

Qg = gas-flow rate, MMscf/D. γ = kinematic viscosity, centistokes, ϕ = absolute viscosity, cp Ql = liquid flow rate, B/D, w = rate of flow, lbm/sec P1 = upstream pressure, psia P2 = downstream pressure, psia. ΔhW = pressure loss, inches of water, W = rate of flow of mixture, lbm/hr, ρM = density of the mixture, lbm/ft3 P = operating pressure, psia, R = gas/liquid ratio, ft3/bbl, T = operating temperature, °R, ΔPZ = pressure drop because of elevation increase in the segment, psi, ΔZ = increase in elevation for segment, ft.

Page 22: Pressure Drop Evaluation Along Pipelines

HL = head loss, ft, Kr = resistance coefficient, dimensionless CV = flow coefficient for liquids, dimensionless. Kr = resistance coefficient, dimensionless,