Page 1: Presentazione standard di PowerPointinjector.railgroup.it/wp-content/uploads/downloads/IG7...gr/sec 2,8 at 1 bar inlet pressure at 2 bar inlet pressure Kg/h 10,3 at 1 bar inlet pressure

IG7 DAKOTA

Page 2: Presentazione standard di PowerPointinjector.railgroup.it/wp-content/uploads/downloads/IG7...gr/sec 2,8 at 1 bar inlet pressure at 2 bar inlet pressure Kg/h 10,3 at 1 bar inlet pressure

1

Page 3: Presentazione standard di PowerPointinjector.railgroup.it/wp-content/uploads/downloads/IG7...gr/sec 2,8 at 1 bar inlet pressure at 2 bar inlet pressure Kg/h 10,3 at 1 bar inlet pressure

2

Page 4: Presentazione standard di PowerPointinjector.railgroup.it/wp-content/uploads/downloads/IG7...gr/sec 2,8 at 1 bar inlet pressure at 2 bar inlet pressure Kg/h 10,3 at 1 bar inlet pressure

3

1

2

3

4

5

6

7

Page 5: Presentazione standard di PowerPointinjector.railgroup.it/wp-content/uploads/downloads/IG7...gr/sec 2,8 at 1 bar inlet pressure at 2 bar inlet pressure Kg/h 10,3 at 1 bar inlet pressure

Very good fluidynamic performance, based on Computational Fluid Dynamics analysis

Specific electromagnetic studies, in order to improve piloting parameters

4

Page 6: Presentazione standard di PowerPointinjector.railgroup.it/wp-content/uploads/downloads/IG7...gr/sec 2,8 at 1 bar inlet pressure at 2 bar inlet pressure Kg/h 10,3 at 1 bar inlet pressure

IG7 DAKOTA - LP

5

Characteristic Unit Value Note

Injector Version N° of

cylinders 2,3,4

Material body and treatment

Aluminium

Relative Pressure Bar (Psi)

From 0,5 to 2,0 (7 to 29)

Working pressure

4,5 (65) Max pressure

Rated voltage (at coil) Volt 10,8 - 14,4

Minimum copper wire section for coil connection

mm2 0,75

Coil type by encoding E2

Resistance Ω 2 ± 5% at T= 25°

Suggested peak current

time (duration) ms 2,4

Suggested peak current value

A

Suggested holding current (±10%)

A 1,4

Cold Starting Requirements

Increase up to 20% the "peak current

time" for first cycles when gas temperature is < 10°C

Complete OPENING Response Time

ms 1,7

(±10% - total injection time 5 ms) ±

5% tested without nozzle at 14V

Dp=1bar T= 25°C

Complete CLOSING Response Time

ms 1,4

Minimum injection pulse ms 1,8

tested with 2 mm nozzle diameter at

14V Δp=1bar T= 25°C

Stroke Micron 470

Seat Diameter mm 3,3

Static flow rate (with max nozzle Φ) for 1 single injector at 20°C (with air)

SLPM (sL/min) 115 at 1 bar inlet pressure

170 at 2 bar inlet pressure

Calculated max flow rate(with max nozzle Φ) for 1 single injector CNG at 20°C (G20 CNG fluid)

gr/sec 1,7 at 1 bar inlet pressure

2,54 at 2 bar inlet pressure

Kg/h 6,2 at 1 bar inlet pressure

9,4 at 2 bar inlet pressure

Characteristic Unit Value Note

Calculated max flow rate(with max nozzle Φ) for 1 single injector LPG at 20°C

gr/sec 2,8 at 1 bar inlet pressure

4,1 at 2 bar inlet pressure

Kg/h 10,3 at 1 bar inlet pressure

14,8 at 2 bar inlet pressure

Leakage (tested with air) cc/h ≤ 15

Noise level dB T.B.D ±1 dB Rail Test

Condition

Compatibility with gas LPG, CNG

Driver Stage Peak and Hold

(PWM)

Coil Connector type

2 way Amp/Delphi super seal fermale connector with tab

contacts

About connecting wire, refer to our drawing, code 114.01.AMP.001

Inlet gas fitting for rubber hose

mm ᴓ10 mm / ᴓ12 mm / ᴓ14 mm / ᴓ16 mm

Outlet gas fitting Calibrated nozzles M8x1 for rubber hose ᴓ 4

mm - ᴓ 5 mm - ᴓ 6 mm

Calibrated hole ᴓ range (for nozzles)

ᴓ From 1,00 to 3,25 mm

(0,25 mm step)

Approvals 110R-00 67R-01 (-40°C / +120°C)

Operating Ambient Temp Range

°C -20° + 120° C

Principle of operation Solenoid valve - Normally closed - Mobile

Plunger

Power handling capability LPG

HP/cyl 1 bar up to 40 HP/cyl

Power handling capability CNG

HP/cyl 2 bar up to 35 HP/cyl

Coil IP Rating IP54

Basic Technical data

Page 7: Presentazione standard di PowerPointinjector.railgroup.it/wp-content/uploads/downloads/IG7...gr/sec 2,8 at 1 bar inlet pressure at 2 bar inlet pressure Kg/h 10,3 at 1 bar inlet pressure

6

Characteristic Unit Value Note

Injector Version N° of cylinders 2,3,4

Material body and treatment

Aluminium

Relative Pressure Bar (Psi)

From 0,5 to 2,0 (7 to 29)

Working pressure

4,5 (65) Max pressure

Rated voltage (at coil) Volt 10,8 - 14,4

Minimum copper wire section for coil connection

mm2 0,75

Coil type by encoding E2

Resistance Ω 2 ± 5% at T= 25°

Suggested peak current time (duration)

ms 2,4

Suggested peak current value

A

Suggested holding current (±10%)

A 1,4

Cold Starting Requirements Increase up to 20% the "peak current time" for first cycles when gas temperature is <

10°C

Complete OPENING Response Time

ms 1,85

(±10% - total injection time 5 ms) ± 5% tested without nozzle at 14V

Dp=1bar T= 25°C

Complete CLOSING Response Time

ms 1,5

Minimum injection pulse ms 1,8

tested with 2 mm nozzle diameter at 14V

Δp=1bar T= 25°C

Stroke Micron 520

Seat Diameter mm 3,8

Static flow rate (with max nozzle Φ) for 1 single injector at 20°C (with air)

SLPM (sL/min)

150 at 1 bar inlet pressure

220 at 2 bar inlet pressure

300 at 3 bar inlet pressure

Calculated max flow rate(with max nozzle Φ) for 1 single injector CNG at 20°C (G20 CNG fluid)

gr/sec 2,3 at 1 bar inlet pressure

3,4 at 2 bar inlet pressure

Kg/h

8,3 at 1 bar inlet pressure

12 at 2 bar inlet pressure

Basic Technical data

Characteristic Unit Value Note

Calculated max flow rate(with max nozzle Φ) for 1 single injector LPG at 20°C

gr/sec

4 at 1 bar inlet

pressure

5,8 at 2 bar inlet

pressure

Kg/h

14,3 at 1 bar inlet

pressure

21 at 2 bar inlet

pressure

Leakage (tested with air)

cc/h ≤ 15

Noise level dB T.B.D ±1 dB Rail Test

Condition

Compatibility with gas LPG, CNG

Driver Stage Peak and Hold

(PWM)

Coil Connector type

2 way Amp/Delphi super seal

fermale connector with tab contacts

About connecting wire, refer to our

drawing, code 114.01.AMP.001

Inlet gas fitting for rubber hose

mm ᴓ10 mm / ᴓ12 mm / ᴓ14 mm / ᴓ16 mm

Outlet gas fitting Calibrated nozzles M8x1 for rubber

hose ᴓ 4 mm - ᴓ 5 mm - ᴓ 6 mm

Calibrated hole ᴓ range (for nozzles)

ᴓ From 1,00 to 3,50

mm (0,25 mm step)

Approvals 110R-00 67R-01 (-40°C / +120°C)

Operating Ambient Temp Range

°C -20° + 120°C

Principle of operation Solenoid valve - Normally closed -

Mobile Plunger

Power handling capability LPG

HP/cyl 1 bar up to 60 HP/cyl with 3,8 mm

nozzle

Power handling capability CNG

HP/cyl 2 bar up to 50 HP/cyl with 3,8 mm

nozzle

Coil IP Rating IP54

IG7 DAKOTA LHF

Page 8: Presentazione standard di PowerPointinjector.railgroup.it/wp-content/uploads/downloads/IG7...gr/sec 2,8 at 1 bar inlet pressure at 2 bar inlet pressure Kg/h 10,3 at 1 bar inlet pressure

7

Basic Technical data IG7 DAKOTA - HP

Characteristic Unit Value Note

Leakage (tested with air) cc/h ≤ 15

Noise level dB T.B.D ±1 dB Rail Test

Condition

Compatibility with gas CNG

Driver Stage Peak and Hold

(PWM)

Coil Connector type

2 way Amp/Delphi super seal fermale connector with tab

contacts

About connecting wire, refer to our drawing, code 114.01.AMP.001

Inlet gas fitting for rubber hose

mm ᴓ10 mm / ᴓ12 mm / ᴓ14 mm / ᴓ16 mm

Outlet gas fitting Calibrated nozzles M8x1 for rubber hose ᴓ 4

mm - ᴓ 5 mm - ᴓ 6 mm

Calibrated hole ᴓ range (for nozzles)

ᴓ From 1,00 to 2,00 mm

(0,25 mm step)

Approvals 110R TO BE DONE ( - 40° to 120°C )

Operating Ambient Temp Range

°C -20° + 120°

Principle of operation Solenoid valve - Normally closed - Mobile

Plunger

Power handling capability CNG

HP/cyl 9 bar up to 84 HP/cyl

Coil IP Rating IP54

Characteristic Unit Value Note

Injector Version N° of

cylinders 2,3,4

Material body and treatment

Aluminium black anodized

Relative Pressure Bar (Psi)

From 0,5 to 7,0 (7 to 100)

Working pressure

9 (130) Max pressure

Rated voltage (at coil) Volt 10,8 - 14,4

Minimum copper wire section for coil connection

mm2 0,75

Coil type by encoding E2

Resistance Ω 2 ± 5% at T= 25°

Suggested peak current time (duration)

ms 3

Suggested peak current value

A

Suggested holding current (±10%)

A 1,6

Cold Starting Requirements

Increase up to 20% the "peak current

time" for first cycles when gas temperature is < 10°C

Complete OPENING Response Time

ms 2 ±5% tested with max ᴓ nozzle diameter at

14V Δp=9bar T= 25°C

Complete CLOSING Response Time

ms 1,3

Minimum injection pulse ms 2,6

Stroke Micron 350

Seat Diameter mm 2

Static flow rate (with max nozzle Φ) for 1 single injector at 20°C (with air)

SLPM (sL/min) 300 at 9 bar inlet

pressure

Calculated max flow rate(with max nozzle Φ) for 1 single injector CNG at 20°C (G20 CNG fluid)

gr/sec 4,5 at 9 bar inlet

pressure

Kg/h 16,1 at 9 bar inlet

pressure

Page 9: Presentazione standard di PowerPointinjector.railgroup.it/wp-content/uploads/downloads/IG7...gr/sec 2,8 at 1 bar inlet pressure at 2 bar inlet pressure Kg/h 10,3 at 1 bar inlet pressure

9

Suggested Peak Limit vs. Temperature

Hold Current [A]

Temperature [ C° ]

Suggested Peak Current limit [A]

1,4 -40 7

1,4 -20 6,7

1,4 -10 6,5

1,4 0 6

1,4 10 5,5

1,4 20 5,5

IG7 DAKOTA DRIVING CURRENT

Page 10: Presentazione standard di PowerPointinjector.railgroup.it/wp-content/uploads/downloads/IG7...gr/sec 2,8 at 1 bar inlet pressure at 2 bar inlet pressure Kg/h 10,3 at 1 bar inlet pressure

10

Suggested Peak value vs. Supply Voltage @ 2 bar inlet pressure

Hold Current [A]

ECU Supply voltage

Suggested Peak Time duration [ms]

1,4 8 3,9

1,4 10 3,3

1,4 11 3

1,4 12 2,8

1,4 13 2,6

1,4 14 2,5

Page 11: Presentazione standard di PowerPointinjector.railgroup.it/wp-content/uploads/downloads/IG7...gr/sec 2,8 at 1 bar inlet pressure at 2 bar inlet pressure Kg/h 10,3 at 1 bar inlet pressure

11

FLOW RATE CHARACTERIZATION

Injector Model

Nozzle Diameter

Dynamic Flow Rate by 3 ms

Injection Time

Static Flow Rate by 20

ms Injection Time

[mm] [cc/stroke] [cc/stroke]

IG7 Dakota LP 1,5 2,70 18,07

IG7 Dakota LP 1,75 3,50 25,27

IG7 Dakota LP 2 4,17 31,97

IG7 Dakota LP 2,25 4,80 39,00

IG7 Dakota LP 2,5 5,27 46,00

IG7 Dakota LP 2,75 5,67 51,77

IG7 Dakota LHF 3 6,60 62,77

IG7 Dakota LHF 3,25 6,77 67,70

Test Parameters:

Flow rate with Air @25°C

Inlet pressure= 2 bar

Ecu supply voltage

= 14V Frequency = 6000

RPM

Page 12: Presentazione standard di PowerPointinjector.railgroup.it/wp-content/uploads/downloads/IG7...gr/sec 2,8 at 1 bar inlet pressure at 2 bar inlet pressure Kg/h 10,3 at 1 bar inlet pressure

12

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

0 2 4 6 8 10 12 14 16 18 20 22

Flo

w R

ate

[cc

/st]

(A

ir)

Injection Time Ti [ms]

1.5 mm Nozzle Diameter

1.75 mm Nozzle Diameter

2.0 mm Nozzle Diameter

2.25 mm Nozzle Diameter

2.5 mm Nozzle Diameter

2.75 mm Nozzle Diameter

3.0 mm Nozzle Diameter LHF

3.25 mm Nozzle Diameter LHF

Page 13: Presentazione standard di PowerPointinjector.railgroup.it/wp-content/uploads/downloads/IG7...gr/sec 2,8 at 1 bar inlet pressure at 2 bar inlet pressure Kg/h 10,3 at 1 bar inlet pressure

13

INDUCTANCE

The inductance is 3.1 mH with open magnetic circuit at 1 kHZ and 300 mV

@ 20 °C

MINIMUM OPENING VOLTAGE

The injector opens for a minimum voltage of 4.4 volts

TEST PARAMETER: 20°C gas temperature, 4.5 bar inlet pressure TEST PROCEDURE: Starting from a voltage of 0 Volts, voltage is gradually increased by 1Volt/s and the voltage at which the injector has opened is observed by means of a flow meter. The test is performed using air as the gas, with an ambient and intake

gas temperature of 20°C and a relative pressure of 4,5 bar.

Page 14: Presentazione standard di PowerPointinjector.railgroup.it/wp-content/uploads/downloads/IG7...gr/sec 2,8 at 1 bar inlet pressure at 2 bar inlet pressure Kg/h 10,3 at 1 bar inlet pressure

8

Page 15: Presentazione standard di PowerPointinjector.railgroup.it/wp-content/uploads/downloads/IG7...gr/sec 2,8 at 1 bar inlet pressure at 2 bar inlet pressure Kg/h 10,3 at 1 bar inlet pressure

9

Page 16: Presentazione standard di PowerPointinjector.railgroup.it/wp-content/uploads/downloads/IG7...gr/sec 2,8 at 1 bar inlet pressure at 2 bar inlet pressure Kg/h 10,3 at 1 bar inlet pressure

10

Technical Diagram

Page 17: Presentazione standard di PowerPointinjector.railgroup.it/wp-content/uploads/downloads/IG7...gr/sec 2,8 at 1 bar inlet pressure at 2 bar inlet pressure Kg/h 10,3 at 1 bar inlet pressure

17

ENDURANCE TEST REPORT

IG7 DAKOTA

Long-life Durability Test parameters Test condition: Feeding with dry and filtered air Nozzle -2 mm diameter Inlet pressure @ 1 bar 25°C ambient and intake temperature 62.5 Hz frequency Activation time 3 ms ECU supply voltage @ 14 Volt The injector stands up to 1,000,000,000 cycles Deviation from starting to after test: Stroke: < ±10 % Dynamic and Static Flow ±8 %

Page 18: Presentazione standard di PowerPointinjector.railgroup.it/wp-content/uploads/downloads/IG7...gr/sec 2,8 at 1 bar inlet pressure at 2 bar inlet pressure Kg/h 10,3 at 1 bar inlet pressure

Separate filter

Y FITTING CODE

Ø10mm

Rubber hose

OP

TIO

NS

Ø12mm rubber hose

Rubber hose

internal Ø10mm

Ø10mm

Rubber hose

Separate filter

Rubber hose

internal Ø10mm

11

CODE 802.02.M12.003

Outlet fitting connector

for map connector

rubber hose D.5/6 mm

CODE : 802.02.M12.010

EL1.00.045.P17(*)

CODE

802.02.M12.009

CODE

802.02.AMP.009

CODE :

802.02.S2N.009

Outlet fitting for map connector hose

D.5/6mm and 4.7KOhm temperature

sensor + version with AMP/SICMA2

connector

CODE 702.02.D12.016

(for D.12mm)

CODE 702.02.D16.002 (for

D.16mm) on request

Standard accessories always included

CODE

790.00.M05.003

Vibration dumping

CODE 702.11.D06.003

Intake manifold

nozzle

CODE :

114.01.AMM.004

(*)EL1.00.045.P17

wired cable

Page 19: Presentazione standard di PowerPointinjector.railgroup.it/wp-content/uploads/downloads/IG7...gr/sec 2,8 at 1 bar inlet pressure at 2 bar inlet pressure Kg/h 10,3 at 1 bar inlet pressure

12

1

2

3

Repair kit available !!

Page 20: Presentazione standard di PowerPointinjector.railgroup.it/wp-content/uploads/downloads/IG7...gr/sec 2,8 at 1 bar inlet pressure at 2 bar inlet pressure Kg/h 10,3 at 1 bar inlet pressure

13

OEM APPLICATION REFERENCES

CAR MANUFACTURERS:

Page 21: Presentazione standard di PowerPointinjector.railgroup.it/wp-content/uploads/downloads/IG7...gr/sec 2,8 at 1 bar inlet pressure at 2 bar inlet pressure Kg/h 10,3 at 1 bar inlet pressure

14

Conclusion

Exchangeable, not very sensitive to dirt accumulation, easy maintenance, easy to clean and easy to calibrate.

Robustness Excellent reliability and durability Compact dimensions Big flow rate Low instability range High installation flexibility on vehicle