presentation airwell vrf 2014 gb

58
SALES PRESENTATION COMMERCIALE RANGE 2014

Upload: arjang-ahmadi

Post on 17-Feb-2017

355 views

Category:

Documents


7 download

TRANSCRIPT

Page 1: PRESENTATION  AIRWELL VRF 2014 GB

SALESPRESENTATION

COMMERCIALE RANGE 2014

Page 2: PRESENTATION  AIRWELL VRF 2014 GB

Document title 2

GAMME VRF 2014

⊙Combinaison maximum : Max 48HP with 3

modules

Possibility to connect maximum 64 units

Page 3: PRESENTATION  AIRWELL VRF 2014 GB

3

Outdoor unit VRF

Page 4: PRESENTATION  AIRWELL VRF 2014 GB

4

Outside Limit temperature

50

40

30

20

10

0

-10

-20

Cooling

Heating

46℃℃℃℃

DB

-15℃℃℃℃

DB

24℃℃℃℃

WB

-15℃℃℃℃

WB

Cooling : de -15 ℃℃℃℃ à +46℃℃℃℃

Heating: de -15 ℃℃℃℃ à +24 ℃℃℃℃

DB : Dry bulbWB : Wet bulb

Page 5: PRESENTATION  AIRWELL VRF 2014 GB

5

10 à 48 HP VRF

VRF INVENTER RANGE:

• 10 to 48 HP (10 à 135 KW)

• Maximum 64 unit for one system

• Dimensions optimisées

• Assemblage modulaire jusqu’à 3 groupes

• 1 compressor Inverter for 10 hp

• 1 compressor Inverter + 1 compressor fixe for 14 and16 HP

Page 6: PRESENTATION  AIRWELL VRF 2014 GB

6

Abundance

The Outdoor units should be selected between 80 and 130% of the total cooling capacities from the indoo r units

Each competitor announce this values as us, but in in a safe and practical way we must selected between 90 and 110% (t be secure in front of exceptional clima tic conditions)

Page 7: PRESENTATION  AIRWELL VRF 2014 GB

7

Outdoor fan speed

Static pressure80 PA

Efficient Structure--Big diameter « aviation » fan, reduce air loss, air resistance, increase heat exchange efficiency-4 way air return, compressors and condenser are placed in separated compartment for a lower sound level

Hélice grand

diamétre,

concept «

aviation »

Page 8: PRESENTATION  AIRWELL VRF 2014 GB

8

Low sound level and « Night » mode

• The compartment compressor is totally separated from the air condenser. Design with insulated casing for a big attenuation of the compressors sound level.

•The setting of the night mode is from the Outdoor unit. Sound attenuation up to -8 dBA

Page 9: PRESENTATION  AIRWELL VRF 2014 GB

9

Back -Up

Function Auto back up

Compresseurs Inverter Fixe Puissance

Alarme Inverter 0%

Alarme Fixe 67%

1 Groupe 2 Compresseurs

Compresseurs Module 2 Module 3 Puissance

Alarme Inverter 33 ou 67 %

Alarme Fixe 80%

Module 1

3 Groupes Extérieurs

Page 10: PRESENTATION  AIRWELL VRF 2014 GB

Document title 10

Automatic Back up

• Backup 24h.

Page 11: PRESENTATION  AIRWELL VRF 2014 GB

Document title 11

EER And COP

0

0,5

1

1,5

2

2,5

3

3,5

4

4,5

5

8HP 10HP 12HP

3,9

3,5 3,44

4,6

4,23,9

EER

COP

Page 12: PRESENTATION  AIRWELL VRF 2014 GB

Document title 12

COMPRESSOR VRF

• Compressor Mitsubishi Electric for all product:

DC FAN MOTOR

AND COMPRESSOR

Page 13: PRESENTATION  AIRWELL VRF 2014 GB

Document title 13

DRV SOUFFLAGE FRONTALE 6HP ET 10HP

VRF YCV ODU 6 HP AIRWELL 7SP14H009AWAU-YCV180-

H13

VRF

NEWYCV

Front DODU 10 HP AIRWELL 7SP14H011

AWAU-

YCVFD280-H13

Possibilités de connecter maximum: 16 unités intérieures

Page 14: PRESENTATION  AIRWELL VRF 2014 GB

Document title 14

Easy installation for Our new Product 10HP

Page 15: PRESENTATION  AIRWELL VRF 2014 GB

Document title 15

Easy maintenance

• Easy maintenance:Maintenance

From the top

Maintenance

From the top

Hinge designHinge design

Page 16: PRESENTATION  AIRWELL VRF 2014 GB

Document title 16

New front discharge 10HP

• High performance and very easy for installation

Page 17: PRESENTATION  AIRWELL VRF 2014 GB

Document title 17

Indoor unit VRF 2014

cassetteFloor and

ceiling

High

pressure

ducted

High wallHigh

pressure

ducted

ConsoleMiddle

pressure

ducted

Low pressure

ducted

Middle

pressure

ducted

Indoor units 2014

Page 18: PRESENTATION  AIRWELL VRF 2014 GB

Document title 18

Low pressure ducted

• Ducted Low pressure:

Possibility connect drain pump.

Static pressure maximum: 20Pa

Wired remote with Just function timer :RWV01

Slim Design (220 mm)

DAV IDU 9

DAV IDU 12

DAV IDU 16

–Wired control as a standard, infra redoptional

–G3 Filter

Page 19: PRESENTATION  AIRWELL VRF 2014 GB

Document title 19

Ducted middle pressure

• Ducted middle pressure:

Drain pump included in standard

Static pressure : 50 Pa

Static pressure maximum: 96 Pa

Wired remote standard RCWV01

DBV IDU 18

DBV IDU 24

DBV IDU 28

DBV IDU 38

Page 20: PRESENTATION  AIRWELL VRF 2014 GB

Document title 20

High pressure ducted

• High pressure ducted

Possibility to connect drain pump

Static pressure standard:100 Pa

Static pressure maximum: 196 Pa

Wired remote standard RCWV01DCV IDU 48

DCV IDU 72

DCV IDU 96

Page 21: PRESENTATION  AIRWELL VRF 2014 GB

Document title 21

Cassette 600*600 et 900*900

• Cassette 600*600 and 900*900

CBV IDU 9

CBV IDU 12

CBV IDU 16

CCV IDU 18

CCV IDU 24

CCV IDU 30

CCV IDU 48

Indoor unit compact with design

unique

Drain pump standard

Possibility add outside airflow

Wired remote standard RCWV01

–drain height up to 600 mm(from the ceiling)

Page 22: PRESENTATION  AIRWELL VRF 2014 GB

Document title 22

K7 600 x 600Air velocity distribution

Cooling mode

Heating mode

Page 23: PRESENTATION  AIRWELL VRF 2014 GB

Document title 23

K7 900 x 900Air velocity distribution

Cooling mode

Heating mode

Page 24: PRESENTATION  AIRWELL VRF 2014 GB

Document title 24

Wall

• wall:

HAV IDU 7

HAV IDU 9

HAV IDU 12

HAV IDU 18

HAV IDU 24

Possibility connect wired remote

–DC fan motor

– Updated design

– Infra red remote control

–Update electronic card withnew function

Page 25: PRESENTATION  AIRWELL VRF 2014 GB

Document title 25

FAV unit Floor and Ceiling

• FAV unit Floor and Ceiling:

FAV IDU 12

FAV IDU 18

FAV IDU 24

Only 199mm

Wired remote standard

Page 26: PRESENTATION  AIRWELL VRF 2014 GB

Document title 26

Floor Ceiling

Air velocity distribution console (heating)

Air velocity distribution ceiling (cooling)

Page 27: PRESENTATION  AIRWELL VRF 2014 GB

Document title 27

Console

– 1 size 12 – Cooling cap 3.6 KW– Heating cap 4 KW– Air supplying from top or bottom of the unit body for fast temperature adjustment–Slim – Integrated EEV– Actual Design– infra red control

Page 28: PRESENTATION  AIRWELL VRF 2014 GB

28

HRV

HRV heat recovery

• Two possibility of using air flow with differentsproducts :800 et 1000 m3/h

• modes : auto/récupération de chaleur/collatéral• Four fan speed• Option timer 24h

Taille 0800 800/900m3/h - 120Pa

Taille 1000 850/1000m3/h - 100Pa

Page 29: PRESENTATION  AIRWELL VRF 2014 GB

29

RCWV01

Maintenance Functions

- Display actual default plus one historical default

-Display of running parameters of the unit

( Temp’s sensor, EEV position)

-Reading physical and centralized address

-Display filter dirty

Page 30: PRESENTATION  AIRWELL VRF 2014 GB

30

Note: Câblage commande 3 fils polarisés

RWV01

Possible installation in :

- Display of set point or ambiance

- Function « I Feel » ( sensor from controller)

-Master and slave (« Va et vient ») - Group commands

(up to 16 units)Compatible with the followingindoor units:

- K7 C B V et C C V.- Ducted units D A V et D B V.- Floor ceiling F A V /HAV

Page 31: PRESENTATION  AIRWELL VRF 2014 GB

31

RWV03

Compatible with the following indoor units :

- K7 C B V et C C V.

- Ducted D A V et D B V.

- Floor / Ceiling F A V /HAV

Installation possibility on :

- Master / slaves - Group command

(up to 16 units)

- Information for preheating and defrost

Page 32: PRESENTATION  AIRWELL VRF 2014 GB

32

RWV03

Basic functions :

-ON / OFF ;-Fan speed selection-Selection mode ;-temperature setting.-Swing setting

Maintenace function:

- Display actual default and one historical default

Type RW V 0 3

Code 7ACELH 008

Page 33: PRESENTATION  AIRWELL VRF 2014 GB

33

RCV01

Type RC V 01Code 7ACELH 001

Basic functions :

-ON / OFF ; Fan speed selectionSelection mode ; temperature setting ; Swing setting

-timer function ( ON ; OFF ; ON/OFF) , Horloge( time display)

Annexe functions:

-Back light ( manual activation)

-Screen and keypad lock

-Information of low battery

Page 34: PRESENTATION  AIRWELL VRF 2014 GB

34

RCV01

Compatible with the following indoor units:

- Wall H A V.- Console E A V .

Page 35: PRESENTATION  AIRWELL VRF 2014 GB

35

RCV01

Type REC 01Code 7ACELH 009

Type RC V 01Code 7ACELH 001

For ducted:Compatible with RCV 01

Page 36: PRESENTATION  AIRWELL VRF 2014 GB

VRF AIRWELL RESIDENTIAL

BMS

Page 37: PRESENTATION  AIRWELL VRF 2014 GB

Document title 37

BMS control (BMV01)

Airwell Residential :

Touch screen

Airwell Residential

Wired remote:

RWV02 ADV01

BACNET :

(BMV03)

Airwell

Residential

Modbus :

ADV03

ADV02 :

ADV02:

+

+

+

Page 38: PRESENTATION  AIRWELL VRF 2014 GB

Document title 38

Software AIRWELL

RESIDENTIAL

b. Protocol convertor

RS

-23

2

RS-485

Ma

x. 3

2x

AD

V0

2

ADV02

……

Max. 40x indoor units

……

……

……

BMV01

homeBUS

……

……

KWh meter

1. RS-485 lengh max est 1000m.

Page 39: PRESENTATION  AIRWELL VRF 2014 GB

Document title 39

Touch screen

Code 7ACELH 003 + Code 7ACELH 004

RWV 02

-Management up to 128 ODU-16 Idoor unit per group -Max wired Length = 1000 ml

Command global functions throughtouch screen :

.Individual control

.Zone control

.Weekly timer

.Default reading

.Central lock….

Mandatory gateway ADV01

+

Page 40: PRESENTATION  AIRWELL VRF 2014 GB

Document title 40

Touch screen

RWV 02

Electrical power 230V, N , 50Hz

ADV 01

Bus

Ma

xi

32

AD

V 0

1

16 Units maxi per group command

128 groups maxi

64 units maxi per

link system

Group N°1 Group N°2 Group N°8

Page 41: PRESENTATION  AIRWELL VRF 2014 GB

Document title 41

RS-485

ADV01 MAXIMUM 64 Indoor units

……

RWV02

homebus

… …

No.1 Group No..2 Group

No..128 group

Ma

x.

32

AD

V0

1

No.1

No..2

No..32

AC single phase

220-240V,50/60Hz

Max. 16 sets indoor units

Page 42: PRESENTATION  AIRWELL VRF 2014 GB

Document title 42

Weekly timer

1. Lengh maximum : 600m.

2. Possibility connect :16.

3. Connect to indoor PCB directly.

RCWV04

Page 43: PRESENTATION  AIRWELL VRF 2014 GB

Document title 43

Modbus ADV03

Page 44: PRESENTATION  AIRWELL VRF 2014 GB

Document title 44

BMS BVM 01

Code 7ACELH 005 + Code 7ACELH 007

ADV 02

Page 45: PRESENTATION  AIRWELL VRF 2014 GB

Document title 45

Page 46: PRESENTATION  AIRWELL VRF 2014 GB

Document title 46

BMS Bacnet

ADV 02

IPC Module

Code 7ACELH 006 + Code 7ACELH 007

Page 47: PRESENTATION  AIRWELL VRF 2014 GB

Document title 47

ADV03Protocol Translator

LonWorks Converter can control up to 32 indoor units

No.1 No..2 No..32

RS

-48

5 m

ax

. 1

00

0m

Lon

Wo

rks

AIRWELL

Net Control

Engine

One LonWorks ADV03 Converter can Only work with ONE

Protocol Translator ADV04

AIRWELL

Metasys

TC

P/I

P

Max.32 indoor units under one IGU06(one modular or

combination outdoor system)

ADV04

SOLUTION LONWORKS

Page 48: PRESENTATION  AIRWELL VRF 2014 GB

Document title 48

Bacnet BMV03+ADV02

Page 49: PRESENTATION  AIRWELL VRF 2014 GB

49

Software selection program

Page 50: PRESENTATION  AIRWELL VRF 2014 GB

50

Project Data

Information to be obtained from the customer (to re alize a nice offer) :

1) Drawings or schemas of the related job 2) Selection conditions (ext / int)3) Kind of (internal units) 4) Kind of controls5) Estimated thermal needs 6) Specific constraints :

1) Outdoor units implantation,2) Way and length piping 3) Available heigth of the ceiling

Page 51: PRESENTATION  AIRWELL VRF 2014 GB

51

Project Data

What we are able to return back to the customer :

1) Precise recap of indoor unit per room with repere

2) Table data with cooling and heating capacities for all the units

3) Complete refrigerant schema tubing with unitary swit ching

4) Electrical connection schema

5) Product offer (from the Led or excel file) + start up

6) Product documentation – VRF Catalog

Page 52: PRESENTATION  AIRWELL VRF 2014 GB

52

Software selection program

• File the project name

• File the customer name

The major steps:

• Information on the rooms to be traited

– Surface– Thermal load au M2 or direct load (calculated by the job engineer)

• Selection of the indoor units

• Selection of the outdoor units

• Edition of the refrigerant schema and filled the pi ping length

• Selection of the global control

• Selection of what we want to print on the final rep ort

• Print the report (Word, PDF,Autocad)

• LED importation and price price calculation

• Send the offer to the customer

Page 53: PRESENTATION  AIRWELL VRF 2014 GB

53

Software selection program

Room configuration

IDU Definition

Validate

Escape

Steps of the selection

Page 54: PRESENTATION  AIRWELL VRF 2014 GB

54

Information for the rooms

Page 55: PRESENTATION  AIRWELL VRF 2014 GB

55

Indoor units selection

Page 56: PRESENTATION  AIRWELL VRF 2014 GB

56

Outdoor unit selectiondétails

ODU with color code

Associated IDU

Alert message

Page 57: PRESENTATION  AIRWELL VRF 2014 GB

57

Outdoor unit selectiondétails

Page 58: PRESENTATION  AIRWELL VRF 2014 GB

58

refrigerant schema piping

Unit details

Tubing Length