LOW REFRIGERANT CHARGE SYSTEM DCE REFRIGERATION PVT LTD. Regd Off : 301/302, Crystal Corporate, Kenjale Nagar Bibwewadi-Kondhwa Road, Bibwewadi, Pune 411037 Works : Gat No 48, Shed No 7, Shindewadi, Tal : Bhor, Dist Pune Ph.no 020 – 24262436 / 56, Fax : 020 – 24263280 Email : [email protected] / [email protected] PRESENTATION BY MR. PRADIP WANI MR. SANJAY ETHAPE +91 98220 33176 +91 98220 96880

Upload: amruta21

Post on 19-Oct-2015

19 views

Category:

Documents


6 download

DESCRIPTION

ASHRAE RPI NIGHT

TRANSCRIPT

LOW REFRIGERANT CHARGE SYSTEM

LOW REFRIGERANT CHARGE SYSTEM

DCE REFRIGERATION PVT LTD.Regd Off : 301/302, Crystal Corporate, Kenjale NagarBibwewadi-Kondhwa Road, Bibwewadi, Pune 411037Works : Gat No 48, Shed No 7, Shindewadi, Tal : Bhor, Dist PunePh.no 020 24262436 / 56, Fax : 020 24263280 Email : [email protected] / [email protected] PRESENTATION BY

MR. PRADIP WANI MR. SANJAY ETHAPE +91 98220 33176 +91 98220 96880

OVER VIEW / COMPARISIONPARTICULARLOW CHARGE RECEIVERLESS SYSTEMCONVENTIONAL SYSTEM WITH RECEIVER COMPONENTSCOMPRESSOR + CONDENSER + EVAPORATOR COMPRESSOR + CONDENSER +EVAPORATOR +RECEIVER EXPANSION DEVICEHP FLOATHAND EXPANSION VALVE LEVEL CONTROL DEVICENOT REQUIREDELECTRONIC FLOAT / LEVEL CONTROLER & SOLENOID VALVEREGRIGERANT CHARGE186 Kg583 KgADDITIONAL CONTROLHIGH LEVEL TRIPMAY BE PROVIDEDPLANT CAPACITY350 TR350 TR

Ammonia charge calculations with receiverSr No.Equipment VolumeVolumeVapour LiquidVapour NH3 Liquid NH3 Total NH3Litersm3%%KgKgKg1Compressor500.000.50000100.00%0.00%1.7300.0001.7302Suction line 94.260.09426100.00%0.00%0.3260.0000.3263Discharge line 60.330.06033100.00%0.00%0.7230.0000.7234Liquid Line 61.940.061940.00%100.00%0.00035.89135.8915Surge Drum 1486.001.4860070.00%30.00%3.599284.692288.2926Ammonia Receiver967.000.9670070.00%30.00%8.111168.106176.2177PHE Condenser 2.4 lit X 56 Cassetees146.400.1464080.00%20.00%1.40316.96718.3718PHE Chiller 1.4 lit X 69 Cassetees96.600.096600.00%100.00%0.00061.69061.690TOTAL AMMONIA CHARGE 15.894567.346583.240

Ammonia charge calculations without receiverSr No.Equipment VolumeVolumeVapour LiquidVapour NH3 Liquid NH3 Total NH3Litersm3%%KgKgKg1Compressor 500.000.50000100.00%0.00%1.7300.0001.7302Suction line 94.260.09426100.00%0.00%0.3260.0000.3263Discharge line 60.330.06033100.00%0.00%0.7230.0000.7234Liquid Line 29.870.029870.00%100.00%0.00017.30817.3085High Pressure Float 19.000.0190040.00%60.00%0.0267.2807.3066Surge Drum 1486.001.4860090.00%10.00%4.62894.89799.5257PHE Condenser 2.4 lit X 56 Cassetees134.400.1344080.00%20.00%1.28815.57616.8658PHE Chiller 1.4 lit X 69 Cassetees96.600.0966030.00%70.00%0.00043.18343.183TOTAL AMMONIA CHARGE 8.722178.245186.967REFRIGERATION SYSTEM WITH RECEIVER

REFRIGERATION SYSTEM WITH RECEIVER

REFRIGERATION SYSTEM RECEIVERLESS

REFRIGERATION SYSTEM RECEIVERLESS

REFRIGERATION SYSTEM RECEIVERLESS

REFRIGERATION SYSTEM RECEIVERLESS

REFRIGERATION SYSTEM RECEIVERLESS

S & T CHILLER & CONDENSER CONVERTED TO PHE & HP FLOAT SYSTEMCHARGED REDUCED FROM 850 KG TO 150 KG.REFRIGERATION SYSTEM WITH RECEIVER

REFRIGERATION SYSTEM RECEIVERLESS

REFRIGERATION SYSTEM RECEIVERLESS

REFRIGERATION SYSTEM RECEIVERLESS

HIGH PRESSURE FLOAT

HIGH PRESSURE FLOAT

Advantages of low charge system-a] Reduced Refrigerant Charge .

b] Can be operated like domestic AC/ Refrigerator.

c] No requirement of opening & closing of valves during start / stop of the system.

d] 100% Safe against liquid stroke & subsequent failures.

e] Suitable for PLC / SCADA operation.

f] Surge Drum can be used as Low Pressure Receiver