preliminary results of mad-x simulations for the fast losses quench test
DESCRIPTION
Preliminary results of MAD-X simulations for the fast losses quench test. Beam. 3-corrector orbital bump Offset of the closed orbit position in the MQ.12L6: 2 cm. Beam. Closed orbit in MCBH.12L6, MS.12L6 and MQ.12L6. Particle tracking (marker after ADT): - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Preliminary results of MAD-X simulations for the fast losses quench test](https://reader034.vdocuments.site/reader034/viewer/2022051621/56814bf5550346895db8e8b0/html5/thumbnails/1.jpg)
Preliminary results of MAD-X simulations for the fast losses quench test
![Page 2: Preliminary results of MAD-X simulations for the fast losses quench test](https://reader034.vdocuments.site/reader034/viewer/2022051621/56814bf5550346895db8e8b0/html5/thumbnails/2.jpg)
2
Beam
3-corrector orbital bumpOffset of the closed orbit position in the MQ.12L6: 2 cm
![Page 3: Preliminary results of MAD-X simulations for the fast losses quench test](https://reader034.vdocuments.site/reader034/viewer/2022051621/56814bf5550346895db8e8b0/html5/thumbnails/3.jpg)
3
![Page 4: Preliminary results of MAD-X simulations for the fast losses quench test](https://reader034.vdocuments.site/reader034/viewer/2022051621/56814bf5550346895db8e8b0/html5/thumbnails/4.jpg)
4
Beam
Closed orbit in MCBH.12L6, MS.12L6 and MQ.12L6
![Page 5: Preliminary results of MAD-X simulations for the fast losses quench test](https://reader034.vdocuments.site/reader034/viewer/2022051621/56814bf5550346895db8e8b0/html5/thumbnails/5.jpg)
Particle tracking (marker after ADT):Orbital bump (10 turns) + MKQ kick (1 turn) + ADT kick
5
![Page 6: Preliminary results of MAD-X simulations for the fast losses quench test](https://reader034.vdocuments.site/reader034/viewer/2022051621/56814bf5550346895db8e8b0/html5/thumbnails/6.jpg)
Beam
MQ.12L6MS.12L6
MQ.12L6, MS.12L6 and drift spaces upstream these magnets were sliced into ~ 1 cm pieces
MCBH.12L6 was sliced into ~ 9 cm pieces
apertureBeam
![Page 7: Preliminary results of MAD-X simulations for the fast losses quench test](https://reader034.vdocuments.site/reader034/viewer/2022051621/56814bf5550346895db8e8b0/html5/thumbnails/7.jpg)
Turn # 33
Particles lost: 3 (0.03%)
Total lost: 3 (0.03%)
Intensity: 10000
Beam
MQ.12L6MCBH.12L63.10.647 0.369
![Page 8: Preliminary results of MAD-X simulations for the fast losses quench test](https://reader034.vdocuments.site/reader034/viewer/2022051621/56814bf5550346895db8e8b0/html5/thumbnails/8.jpg)
Turn # 40
Particles lost: 94 (0.94%)
Total lost: 97 (0.97%)
Beam
Intensity: 10000
MQ.12L6MCBH.12L63.10.647 0.369
![Page 9: Preliminary results of MAD-X simulations for the fast losses quench test](https://reader034.vdocuments.site/reader034/viewer/2022051621/56814bf5550346895db8e8b0/html5/thumbnails/9.jpg)
Turn # 44
Particles lost: 341 (3.41%)
Total lost: 438 (4.38%)
Beam
Intensity: 10000
MQ.12L6MCBH.12L63.10.647 0.369
![Page 10: Preliminary results of MAD-X simulations for the fast losses quench test](https://reader034.vdocuments.site/reader034/viewer/2022051621/56814bf5550346895db8e8b0/html5/thumbnails/10.jpg)
Turn # 47
Particles lost: 48 (0.48%)
Total lost: 486 (4.86%)
Beam
Intensity: 10000
MQ.12L6MCBH.12L63.10.647 0.369
![Page 11: Preliminary results of MAD-X simulations for the fast losses quench test](https://reader034.vdocuments.site/reader034/viewer/2022051621/56814bf5550346895db8e8b0/html5/thumbnails/11.jpg)
Turn # 51
Particles lost: 6363 (63.63%)
Total lost: 6849 (68.49%)
Beam
Intensity: 10000
MQ.12L6MCBH.12L63.10.647 0.369
![Page 12: Preliminary results of MAD-X simulations for the fast losses quench test](https://reader034.vdocuments.site/reader034/viewer/2022051621/56814bf5550346895db8e8b0/html5/thumbnails/12.jpg)
Turn # 58
Particles lost: 2846 (28.46%)
Total lost: 9695 (96.95%)
Beam
Intensity: 10000
MQ.12L6MCBH.12L63.10.647 0.369
![Page 13: Preliminary results of MAD-X simulations for the fast losses quench test](https://reader034.vdocuments.site/reader034/viewer/2022051621/56814bf5550346895db8e8b0/html5/thumbnails/13.jpg)
Turn # 62
Particles lost: 66 (0.66%)
Total lost: 9761 (97.61%)
Beam
Intensity: 10000
MQ.12L6MCBH.12L63.10.647 0.369
![Page 14: Preliminary results of MAD-X simulations for the fast losses quench test](https://reader034.vdocuments.site/reader034/viewer/2022051621/56814bf5550346895db8e8b0/html5/thumbnails/14.jpg)
Turn # 65
Particles lost: 112 (1.12%)
Total lost: 9873 (98.73%)
Beam
Intensity: 10000
MQ.12L6MCBH.12L63.10.647 0.369
![Page 15: Preliminary results of MAD-X simulations for the fast losses quench test](https://reader034.vdocuments.site/reader034/viewer/2022051621/56814bf5550346895db8e8b0/html5/thumbnails/15.jpg)
Turn # 69
Particles lost: 127 (1.27%)
Total lost: 10000 (100%)
Beam
Intensity: 10000
MQ.12L6MCBH.12L63.10.647 0.369
![Page 16: Preliminary results of MAD-X simulations for the fast losses quench test](https://reader034.vdocuments.site/reader034/viewer/2022051621/56814bf5550346895db8e8b0/html5/thumbnails/16.jpg)
Turn # 69
Particles lost: 127 (1.27%)
Total lost: 10000 (100%)
Beam
Intensity: 10000
MQ.12L6MCBH.12L63.10.647 0.369
![Page 17: Preliminary results of MAD-X simulations for the fast losses quench test](https://reader034.vdocuments.site/reader034/viewer/2022051621/56814bf5550346895db8e8b0/html5/thumbnails/17.jpg)
Primary beam:εn (x) = 1.75e-6εn (y) = 10.0e-6
![Page 18: Preliminary results of MAD-X simulations for the fast losses quench test](https://reader034.vdocuments.site/reader034/viewer/2022051621/56814bf5550346895db8e8b0/html5/thumbnails/18.jpg)
18
![Page 19: Preliminary results of MAD-X simulations for the fast losses quench test](https://reader034.vdocuments.site/reader034/viewer/2022051621/56814bf5550346895db8e8b0/html5/thumbnails/19.jpg)
Beam