preheating studies for laser-driven maglif on omega

22
Preheating Studies for Laser-Driven MagLIF on OMEGA J. R. Davies University of Rochester Laboratory for Laser Energetics & Mechanical Engineering Fundamental Science with Pulsed Power Albuquerque NM July 19 22 2015 Target support 0.6 mm 1.84 m polyimide foil (Entrance window) Cylinder (Shown with coil) Cylinder (Without shield) Window MIFEDS Fill tube Shield

Upload: others

Post on 16-Oct-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Preheating Studies for Laser-Driven MagLIF on OMEGA

Preheating Studies for Laser-Driven MagLIF on OMEGA

J. R. Davies

University of Rochester

Laboratory for Laser Energetics

& Mechanical Engineering

Fundamental Science with Pulsed Power

Albuquerque NM

July 19 – 22 2015

Target

support

0.6 mm

1.84 m polyimide foil

(Entrance window)

Cylinder

(Shown with coil)

Cylinder

(Without shield)

Window

MIFEDS

Fill

tube

Shield

Page 2: Preheating Studies for Laser-Driven MagLIF on OMEGA

Preliminary analysis of experiments on OMEGA indicate that adequate preheating is achieved

• Transmission through entrance window foils along the original beam

path exceeds 50%

• Backscatter from foil-only and cylinders is similar, lasts around 0.5 ns

and accounts for less than 1% of the laser energy

• Just under 10% of the laser energy is side scattered as the foil starts to

transmit

• Optical and soft X-ray emission indicate that the gas is heated along the

full length of the target to at least 100 eV

Summary

Page 3: Preheating Studies for Laser-Driven MagLIF on OMEGA

Collaborators

D. H. Barnak, R. Betti, E. M. Campbell, P.-Y. Chang, G. Fiksel and W. Seka

University of Rochester

Laboratory for Laser Energetics

K. J. Peterson, A. B. Sefkow, D. B. Sinars and S. A. Slutz

Sandia National Laboratory

Page 4: Preheating Studies for Laser-Driven MagLIF on OMEGA

An OMEGA beam with 60 to 200 J in 2.5 ns and a phase plate giving a 96 m FWHM Gaussian spot was used giving peak laser intensities of 2.3 to 7.6 1014 W cm-2

B25

FABS

Hex Cal B46

FABS

1.84 m polyimide foil

(Entrance window)

Cylinder

(Shown with coil)

Cylinder

(Without shield)

0.6 mm

600 m outer diameter, 30 m thick parylene-AF4

cylinders filled with 1.6 mg/cc 2%at Ne doped D2

Soft X-ray diagnostic window

B25

B25 or B65

Window

MIFEDS

Fill

tube

Shield

Page 5: Preheating Studies for Laser-Driven MagLIF on OMEGA

Foil transmission along the original beam path exceeded 50% and increased with laser energy

Page 6: Preheating Studies for Laser-Driven MagLIF on OMEGA

Time resolved spectra of backscattered or transmitted light were measured at three angles

Target

(Laser axis) 24.8

16.6

Page 7: Preheating Studies for Laser-Driven MagLIF on OMEGA

Backscatter from foils and cylinders was similar and lasted around 0.5 ns

Time resolved spectra through the laser beam port 25

(log scale)

Cylinder 203.3 J Foil 195.6 J

Page 8: Preheating Studies for Laser-Driven MagLIF on OMEGA

Backscatter from foils and cylinders was similar and lasted around 0.5 ns

Small increase in backscattered

power at later times in cylinders

Reflection from cylinder that

varied in angle from shot to shot

Page 9: Preheating Studies for Laser-Driven MagLIF on OMEGA

Foil transmission measurements showed side scattering lasting less than 0.5 ns

198.4 J

Page 10: Preheating Studies for Laser-Driven MagLIF on OMEGA

Total backscatter and transmission for foils at 200 J was obtained by fitting data from 2 shots with a Gaussian radial intensity profile

0.5% backscattered

63.4% forward transmission

8.7% sidescattered transmission

27% absorbed

Page 11: Preheating Studies for Laser-Driven MagLIF on OMEGA

Streaked optical pyrometery of the cylinder surface demonstrates energy coupling along the central 0.8 mm

Shock breakout

Blanking Outer surface

heats up

Inner surface

heats up

0.8 mm

Laser

Shield

SOP View

Page 12: Preheating Studies for Laser-Driven MagLIF on OMEGA

VISAR confirmed shock breakout but in some shots there was no shock seen in either SOP or VISAR

Laser Laser

Shock breakout

Time Time

Page 13: Preheating Studies for Laser-Driven MagLIF on OMEGA

The time resolved X-ray spectrometer DANTE was used to measure emission from the entrance window or from the side diagnostic window

DANTE Response Function

View with beam 25 View with beam 65

Page 14: Preheating Studies for Laser-Driven MagLIF on OMEGA

Signal was obtained on 5 channels from the entrance window that appears to contain signal from the gas

(900 – 980 eV FWHM)

Emission from gas?

Emission from wall?

Emission from

window

Page 15: Preheating Studies for Laser-Driven MagLIF on OMEGA

The signal from the side diagnostic window was barely above the noise level in only 2 channels

Doped

Undoped

Page 16: Preheating Studies for Laser-Driven MagLIF on OMEGA

Mirror-filter pairs coupled to X-ray framing cameras gave 3-channel, time resolved X-ray spectrometers (SXR)

1.3 ns

1.9 ns

2.5 ns

3.1 ns

1 2 3

1 2 3

F F Ne Ne

Page 17: Preheating Studies for Laser-Driven MagLIF on OMEGA

DANTE and SXR data are being modeled with Spect3D to infer the gas temperature

• The data is insufficient to give a unique solution

• The best that can be achieved is placing bounds on the gas and wall

temperatures

• Preliminary results indicate that the gas temperature at the center

exceeded the goal of 100 eV

• Spect3D will be used to post-process hydrocode results to allow a direct

comparison with the soft X-ray measurements

Page 18: Preheating Studies for Laser-Driven MagLIF on OMEGA

Hard X-ray, 3/2, Raman scattered light and neutron detectors were also fielded

• No detectable hard X-ray or 3/2 emission

– Two plasmon decay is not significant

• A weak Raman scattered signal was detected in some cylinder shots

– Brief emission at early times that has yet to be analyzed

• The neutron scintillator detected from 2 to 4 DD fusion neutrons

– Total yields 105 neutrons

– Yields appear to be higher for magnetized shots

Page 19: Preheating Studies for Laser-Driven MagLIF on OMEGA

The experiments are being modeled in 2D with Draco and Flash

• Sample results from Draco for a cylindrical target

– Burn through time is consistent with experiment

– Sidescattering of transmitted light is seen due to refraction near the edge of

the expanding hole in the window

• Draco and Flash will be used to model SOP, soft X-ray emission and the

streaked, back scattered spectrum

Log[Te(eV)] at 0.4 ns Log[(g/cc)] at 0.4 ns

Page 20: Preheating Studies for Laser-Driven MagLIF on OMEGA

Preliminary analysis of experiments on OMEGA indicate that adequate preheating is achieved

• Transmission through entrance window foils along the original beam

path exceeds 50%

• Backscatter from foil-only and cylinders is similar, lasts around 0.5 ns

and accounts for less than 1% of the laser energy

• Just under 10% of the laser energy is side scattered as the foil starts to

transmit

• Optical and soft X-ray emission indicate that the gas is heated along the

full length of the target to at least 100 eV

Summary

Page 21: Preheating Studies for Laser-Driven MagLIF on OMEGA

Six shots were taken on just the entrance window foils

Shot # E (J) Diagnostics

76671 212.6 FABS backscatter, Hex Cal transmission, DANTE

76676 195.6 FABS backscatter, Hex Cal transmission, DANTE

76677 108.1 FABS backscatter, Hex Cal transmission, DANTE

76679 198.4 FABS transmission, DANTE

76680 113.8 FABS transmission, DANTE

76681 63.1 FABS transmission, DANTE

Page 22: Preheating Studies for Laser-Driven MagLIF on OMEGA

Twelve shots were taken on gas filled cylinders

Shot # E(J) P(atm) Ne B(T) Front diagnostics Side diagnostics

76673 203.3 10 Y 15 FABS, DANTE Nothing

76674 202.0 10 Y 15 FABS, DANTE Nothing

76675 198.9 10 Y 0 FABS, DANTE SOP (over filtered)

76678 191.6 10 Y 0 FABS, DANTE SOP

76682 209.3 5 Y 0 FABS, DANTE SOP

76683 201.7 7.5 Y 0 FABS, DANTE SOP

76966 228.6 10 Y 0 SXR SXR, SOP-VISAR, DANTE

76967 200.8 10 Y 0 SXR SXR, SOP-VISAR, DANTE

76968 202.4 10 Y 0 SXR SXR, SOP-VISAR, DANTE

76969 196.4 10 N 0 SXR SXR, SOP-VISAR, DANTE

76970 198.8 10 Y 0 SXR SXR, SOP-VISAR, DANTE

76971 198.7 10 N 0 SXR SXR, SOP-VISAR, DANTE