preface - arb.lk volume ii.pdf · preface this development plan has been prepared for the...
TRANSCRIPT
PREFACE
This development plan has been prepared for the implementation of the development of
Ratnapura Municipal Council area within the next three decades. The aim of this plan is to
make Ratnapura, an attractive sustainable capital city of the Sabaragamuwa Province. It has
also been proposed to develop, Ratnapura city on dual centered concept with new
administrative centre at new town and the commercial centre at old town. Which has been
linked by a well planned network of roads. Ratnapura town is a disaster prone area and the
commercial town is subjected to flooding twice in an year.
Having considered all these facts necessary steps have been introduced to minimize the
disaster and to develop the town physically, economically, socially and environmentally
viable area.
iii
ACKNOWLEDGEMENT
The Planning Team of Urban Development Authority, Ratnapura District Office in
Sabaragamuwa Province is grateful to the following institutions along with the UN-
Habitat for their coordination, for providing necessary technical equipment and for their
support in successfully conducting the stakeholder meetings regarding the development
plan. At this moment we are extremely thankful to Plnr. Indu Weerasoori Project
Manager of DRR and her team and Ms. Kaushalya Jayalath DRR Projects Office for
their help at various stages of this Ratnapura Development Plan for the support given by
them in the preparation of this plan.
Ratnapura Municipal Council
Ratnapura District Secretariat
Ratnapura Divisional Secretariat
National Physical Planning Department
Road Development Authority
Ceylon Electricity Board
National Water Supply and Drainage Board
Archeology Department
Ministry of Health
Provincial Council (Sabaragamuwa Province) and Ministries
Central Environmental Authority
Census and Statistics Department
Postal Department
The Team would like to express the gratitude to the Chairman, Director General and
Development Planning Division of the Urban Development Authority for the immense
encouragement and support given to prepare and finalized of this plan.
iv
The Team which participated for the Town Development Plan of
Ratnapura Municipal Council Area
1. Ms. I.S. Weerasoori, Former Dy. Director General (Planning)
2. Mr. W. Gunaratne, Former Director (Sabaragamuwa Province)
3. Mr. P.K.D. Pathirana, Former Director (Sabaragamuwa Province)
4. Ms. J.P.S. Somasekara, Dy. Director (Planning), Head Office
5. Ms. S.D.D.N. Kulatunga, Dy. Director (Planning), Head Office
6. Mr. D.A.D. Athukorala, Asst. Director (Planning)
7. Ms. K.A.S. Gunasekara, Planning Officer
8. Ms. H.K.D. Manori Krisenta, Planning Officer
9. Ms. H.K. Neelika, Planning Officer
10. Mr. K.M.I. Saman Rupasinghe, Planning Officer
11. Ms. S.P.S. Kumari, Planning Officer
12. Ms. A.P. Priyangi Bandarawatte, Planning Assistant
13. Ms. Sakitha Nawaratne, Planning Assistant
14. Ms. W.M. Wathsooriya, Draughtsman
15. Ms. M. Nadeeka Gunawardena, Draughtsman
16. Ms. Kaushalya, UN-Habitat
17. Ms. T.B. Sandya, GIS Officer
18. Ms. K.M.J. Hemalatha, Typist
19. Ms. Chandima Gunaratne, Typist
20. Ms. Dileepa Weeraratne, Typist
21. Ms. Roshani Thilangika, Typist
22. Ms. U.G.H. Rupasinghe, Computer Operator, Head Office
23. Mr. H.P. Wijesiri, Office Aide
24. Mr. Samantha Munasinghe, Office Aide
25. Mr. Anton Jenis Silva, Driver
v
CONTENT
Page No.
Chapter 01
Proposed Development Plan
1.1 Introduction 01
1.2 Vision 01
1.3 Concept of the Plan 01
1.4 Contents of the Plan 02
1.5 Objective and Strategies 04
1.6 Recommended Projects for the Town 05
Chapter 02
Proposed Sub Plans
2.1 Proposed Zoning Plan 2013 - 2030 07
2.2 Factors Based for Zoning 07
2.3 Proposed Zones 08
2.4 Proposed infrastructure Service Development Plan 10
2.5 Proposed Public Outdoor and Recreation Plan for 17
Ratnapura Urban Development Area
2.6 Environmental Plan for Ratnapura Municipal Council Area 23
Chapter 03
Regulations
3.1 General Regulations 34
3.2 Zoning Classifications 35
Part I - Planning & Building Regulations 41
Part II - Planning Conditions 47
Part III - Building Conditions 62
Part IV - Definitions 76
Part V - Schedules 79
Annexure – I - Planning specifications to follow for Site 111
Inclination in Residential Zones.
Annexure – II - The road reserves in the 112
Ratnapura Municipal Council Division
Annexure – III - Rivers and canal reservations 117
Annexure – IV - Dangerous and unpleasant businesses 118
Annexure – V - Conserved buildings 119
Annexure – VI - Proposed Floor Area Ratio 119
vi
Annexure – VII - Reservation requirements for mining 120
Annexure – VIII - Special requirement that fulfilled for Flood Victim
areas 121
Annexure – IX - Special requirements that fulfilled for landslide 121
areas
Annexure – X - Zonal Boundaries 122
List of Maps
Page No.
1. Development Concept 03
2. Proposed Housing Projects – Ratnapura 06
3. Zoning Plan – 2013 –Ratnapura Urban Area 09
4. Proposed alternative Roads – Ratnapura 12
5. Proposed Vehicle Parks – Ratnapura Urban Area 13
6. Water Supply System – 2013 - Ratnapura Urban Area 14
7. Drainage System - Ratnapura Urban Area 16
8. Proposed Outdoor Recreation Plan- 2030 Ratnapura Urban Area 18
9. Water Retention Areas - Ratnapura Urban Area 22
vii
CHAPTER 01
Proposed Development Plan
1.1 Introduction
To give suitable solutions for social, economic and environmental problems that are
associated with the town, to develop the base through a people assessment process to
the town‟s resources and opportunities, to make a physical development
commensurate the future public demand, to encourage the future development works
systematically with a planned manner and to enhance peoples‟ living standard by
minimizing natural disasters are expected by this plan and it is due to implement this
plan for a period from 2013 to 2030.
1.2 Vision
The vision of this plan is to make Ratnapura as a stable, safe, attractive capital town
of Sabaragamuwa Province.
1.3 Concept of the Plan
Ratnapura is the capital of Sabaragamuwa Province. According to the National
Physical Policy and Plan of Sri Lanka, it is a main town of the district and includes
to ecological high sensitive Central Fragile area as it often faces to disasters.
Accordingly, the urban development must be done with limited and methodical
manner. Therefore, only very carefully selected areas must be referred to the
development and risky areas must be conserved as ecological in sensitive zones.
Taking into consideration of the above facts, it is appropriate to develop Ratnapura
town with a plan based on Dual Centre Concept. Accordingly, it is suggested by
this plan to develop it as a town consisting a road network by efficiently connecting
a new town where centralized the administrative functions and an old town where
centralized the commercial activities. It is suggested by this plan to facilitate for
residential affairs too by leaving the areas face to disasters associated to the said
focuses. Accordingly,
1. Old Town (Commercial Center)
To facilitate for further development of the old urban area that has presently
been developed as a commercial center to which exists a broad demand for
further commercial activities.
2. New Town (Administrative Center)
Relocation of administrative institutions from old town to the new town has
presently been finalized by and about 90%, it has been proposed to establish
the remaining institutions and newly established administrative institutions
around the new town and to develop the essential facilities and to develop the
facilities required for residential purposes is proposed.
01
As the Ratnapura town is situated in a high sensitive zone under the National
Physical Planning Policy, no permission will be granted except small scale
industries in urban area for such opportunities to commence the large scale
and medium scale industries and the said requirements will be referred to
Nanda Ellawala Millennium Industrial Area of Kuruvita situated about 5 km.
away from the town. (Map No. 01)
Also it has been identified that Ratnapura is a town which can‟t further be
expand under the National Physical Planning Policy and has pointed out the
targeted population may not exceed i.e. 75,000.
Accordingly, it is expected to expand the present urban limit to the optimum
land areas, to develop the said optimum lands and the urban centralized
population will be controlled by concentrating and directing the development
to North.
1.4 Contents of the Plan
The development plan prepared for Ratnapura urban area will be further described
under secondary plans.
1. Zoning Plan
2. Transportation Plan
3. Proposed Recreation & Open Space Plan
4. Town Centre Development Plan
5. Zoning Regulations & Zoning Boundaries
6. Sub Divisions and Building Regulations
02
1.5 Objectives and Strategies
Objectives Strategy
1. Fulfillment of demand to the land
for various needs in 2030.
Zoning of land uses commensurate to
future demand.
2. Development of living standard of
the residential community in the
town.
Establishing sports and recreation
facilities commensurate to the urban
community and commuter population
Systematical development of Gem
Industry.
3. Reducing disasters occurred due to
natural hazards
- Conservation of the identified
places where natural disasters may
occur.
- Introduction of disaster
management strategies.
- Introduction of conservation areas,
controlling of density, enacting
plans and building regulations to
minimize disasters by technical
methods.
4. Increasing job opportunities for
people in urban and catchment areas
in commercial and service sector in
the town.
Development of required places and
relevant facilities to establish
commercial services facilities.
5. Protection of ecological sensitivity
and natural beauty in the urban area
Identification, maintaining of reserves
for rivers, canals that are streaming
through the town and development of
linear parks and protection of
attractive places.
6. Distribution of physical, ecological
and social infrastructure facilities all
over the town.
Guidance for infrastructure facilities
through introducing the building
density.
Expansion of roads, constructing
alternative roads and providing
required spaces for vehicle parks.
7. Safeguarding of Ratnapura Maha
Saman Devala Premises.
Identification of Devala Premises as a
sacred zone and enacting relevant
guidelines for that.
8. Carrying on the development
process as to minimize the disasters.
Implementation of Development
Guide Plans
04
9. Increasing of contribution towards
the gross national production.
Increasing of infrastructure facilities
as to expand opportunities for
investments and minimizing of
disaster situations.
The following suggestions are submitted to achieve afore mentioned objectives and thereby
it is expected to reach to a considerable development by 2030.
1.6 Recommended Projects for the Town
1. Construction of gems and jewelry exhibition and trade center.
2. Construction vehicle parks (Near Seewali stadium, near museum park)
3. Construction of a commercial complex.
4. Development of a place for commercial activities.
5. Construction of urban parks – new town.
6. Kalu Ganga river bank conservation project.
7. Construction of a cultural center.
8. Construction of a park near the museum.
9. Development of drainage system for disposing rain water.
10. Construction of a solid waste management center.
11. Housing development (Map No. 02).
i. Medium class housing project. (Farm Garden Watta - 33 Acres)
ii. High income housing project-New town of Ratnapura.
iii. Housing project for unauthorized settlers implemented with the Land
Reform Commission,
05
CHAPTER 02
Proposed Sub Plans
2.1 Proposed Zoning Plan 2013 - 2030
Taking into consideration of the existing land use pattern, the town will concentrate
to a planned land utilizing pattern by the proposed land utilizing plan prepared for
2030.
Accordingly, land utilization in the town has been classified to cater for the future
demand. Thereby, it is expected to further protect the lands that must be conserved
in Ratnapura town, to minimize the traffic congestion in town center and to
concentrate for development of infrastructure facilities needed for urban people.
Further, in concentrating to a targeted development, minimizing of urban problems
and the development will be guided in accordance to the national level policies.
Thereby, a sustainable development with minimized disasters will be carried out by
the zoning plan with integration of social, economic and environmental sectors.
2.2 Factors Based for Zoning
The following factors were taken into consideration in preparation of land use
pattern for future needs in Ratnapura town.
1. According to the existing population growth rate and future population
growth tendency and effects, based on 1.5 annual average population
growths, the population in the area to be 64,340 by 2030.
2. Availability of land plots for development according to the prevailing land
utilization pattern and physical features. Here, zoning will be carried out in
development process without leaving and optimum utilization of steep slope
areas, landslide prone areas, areas vulnerable to flood and the conservation
areas.
3. Allocating an extent of 10% lands for transportation purpose.
4. The development process is carried out based on the land inclination and
altitude due to minimum availability of lands according to the existing
geographical situation.
5. Minimum availability of 10% from residential areas for community base &
public activities.
6. Allocation of 1 hectare per 1000 persons for leisure and recreational
activities.
07
2.3 Proposed Zones
Based on above factors, the Ratnapura Municipal Council area has divided into
several main zones which indicate in the Map No. 03.
Proposed Land Utilization Plan 2013 – 2030
Table No. 01
Serial
No.
Utilization
Extent in
Hectares
Percentage from
the Whole Land
by 2030
01
1.1
1.2
Residential zone
Low density residential zone
High density residential zone
649.61
105.00
544.61
28.80
5.00
23.80
02 Mixed residential zone 359.74 17.18
03 Commercial zone 46.00 2.02
04 Administrative zone 75.00 3.40
05 Pooja Bhoomi zone (Saman Devalaya) 4.20 0.20
06 Special conserved zone 401.00 18.00
07 Ecological sensitive zone 385.93 17.40
08 Roads 221.00 10.00
09 Water ways 75.70 3.00
Total 2218.00 100.00
Source : Urban Development Authority – Sabaragamuwa Provincial Office
1. Residential Zone
Taking into consideration of prevailing residential density of all over the
town, 02 zones has been selected and classified as most suitable areas for
residential facilities and increased up to 1010.00 hectares.The residential
usage within proposed zoning plan has been increased by 3% and the
residential usages in the new town and around may be increased by
expanding the town in future.
1.1 Law Density Residential Zone
The key objective of introducing law density residential zones is
systematic establishment of residential development according to the
land inclination based on minimizing disasters in slope areas.
Accordingly, the natural disasters, especially risk situations may
occur due to landslides can be controlled.
1.2 High Density Residential Zones
The key objective of utilizing high density residential zones is mostly
centralizing the residential utilization towards suitable areas rather
than localizing residential usages.
08
2. Mixed Residential Zone
The prevailing areas that has been achieved a mixed development and the
residential areas expected to achieve a commercial and mixed developmentin
future, has been named as mixed residences which is amounting to 17.18%.
3. Commercial Zone
The commercial zone has been introduced for further establishment of the
development consisting a high commercial density in central area of the
town.The allocated land extent for commercial zone is 46 hectares. In
addition to this, mixed residential zones have been introduced as to establish
commercial utilizations. Therefore, opportunity has been given to increase
commercial utilizations within the said zone too and by expanding the new
town, the future commercial lands utilization from areas related to the new
town and Kuruvita Industrial Area can be increased.
4. Administrative Zone
The area related to new town where centralized zonally important
Government and Semi Government institutions have been allocated for
administrative functions. Only those Government and Semi Government
institutions that must maintain fast public affairs are approved to establish
their branches in areas close to central town.
5. Pooja Bhoomi Zone
The present Saman Devala premises which is historically and
archaeologically important has been name as a Pooja Bhoomi Area. Its
objective is assure to utilize the said area in compliance to Saman Devalaya
Holly Land.
6. Ecologically Sensitive Zone and Special Conserved Zone
Conservation of places victimized due to natural disasters and establishing
the natural environment, the agriculture, low lands and water reserves have
been established to minimize the effects occurred by human settlements
development and has named as a special conservation zone based on the
intensity of ecological sensitivity.
2.4 Proposed Infrastructure Services Development Plan
The following recommended development suggestions are submitted as solutions for
prevailing problems in Ratnapura town,
Road Development
The road network connected locally and regional\y within Ratnapura town plays a
special role to urban area. The following road development projects are suggested by
this plan to minimize road congestion occurs due to insufficiency of prevailing roads
and non-availability of by-roads.
10
Roads Proposed to Develop by Expanding
i. Development of the river edge road.
ii. Development of the outer circus road.
iii. Development of Weralupa road. (Godakawela road)
iv. Development of internal circus road.
v. Development of Goodshed road.
The Alternative Roads Suggested by the Plan- (Map No. 04)
i. Construction of an alternative road to connect the new town across
Kospelawinna which begins nearby Warathota Bridge up to Malwala
Junction.
ii. Strengthen of transportation network affiliated to the new town by
connecting present Ratnapura – Panadura road along Ketaliyanpalla road.
iii. Development of Old Batugedara Road
Passenger Transportation Services
The urban transportation system of Ratnapura town is situated centralizing the old
town. In addition to this, an extent of 1 acre land has been allocated to establish a
systematic transportation service within the administrative zone. Accordingly,
suggestions are made by this plan to regulate the transportation service.
i. Further development of the old town‟s bus-stop. (short distance services)
ii. Development of new town‟ bus-stop. (for long distance services)
iii. Development of vehicle parks. (Map No. 05)
iv. Make suggestions for night transportation services.
v. Establishment of proposed railway station relating to the new town.
Water Supply
The prevailing water supply in Ratnapura town is insufficient for urban area.
Following suggestions are made to fulfill the increasing water consumption. (Map
No. 06)
i. Further development of existing water supply system under extensive water
scheme. (increasing the capacity)
ii. Awareness programmes for safe usage of unprotected wells.
iii. Increasing capacity of the water tank in “Pompa Kele” Forest) by 13000
cubic meters.
iv. Construction of a water tank in the new town with a capacity of 10,000 cubic
meters.
v. Construction of a new well nearby river edge road.
vi. Development of communal water facilities by small water projects.
11
Solid Waste Management
i. Further development of Municipal Council‟s compost project.
ii. Construction of a sanitary waste discarding project related to the waste
discarding land situated at Kanadola.
iii. Further regularizing of present available solid waste converting project into
compost under Sewanatha Institution and United Nations Development
Programme.
Sewerage
i. Introduction of a central sewerage system.
ii. Counseling public to use only water-sealed toilets.
Rain Water Drainage System
Facing to sudden floods in heavy rainy season is a main problem due to non-
availability of planned drainage system in the town. The reason for that is irregular
drainage system and not duly maintained. Therefore, a planned drainage system for
Ratnapura town is submitted by this plan. (Map No. 07)
i. Construction of a drainage system covering the whole urban area as to abate
surface water.
ii. Taking action to avoid impure water releasing the surface drainage system.
iii. Implementation of a systematic measurement together with the Municipal
Council for systematic maintenance of drainage.
Electricity Supply
i. Development of electricity supply system.
ii. Solving of administrative problem regarding the prevailing street
illumination related to the town.
Education
i. Facility development of prevailing schools.
ii. Provision of required facilities to localize International schools and other
institutions.
iii. Localizing of the proposed Medical Faculty of Sabaragamuwa University
related to the town.
iv. Establishment of a vocational training center in the town to increase
opportunities to follow vocational courses.
Health
i. Take steps to solve the prevailing problems related to Ratnapura general
hospital.
ii. Establishment of an International level private hospital related to the town.
iii. Implementation of plans and building regulations describing the ways of
developments as to face natural disasters.
15
Natural Resources
i. Minimize disasters by implementing zoning plan.
ii. Introduce special regulations while constructing buildings in the flood zone.
2.5 Proposed Public Outdoor & Recreation plan for Ratnapura Urban
Development Area
According to the Urban Development Authority‟s standards, a minimum extent of
1.4 hectares per 1000 population must be allocated for common open space while
preparing the development plan. Census statistic records indicate that the population
within Ratnapura Municipal Council Area in 2011 was 49,083. According to the
development plan‟s data analysis, it has predicted that the population by 2030 as
64,340. Accordingly, a minimum extent of 85.6 hectares has to be allocated as
common open spaces by 2030.
2.5.1 Space Plan Regarding the Proposed Public Outdoor & Recreation Activities.
According to the prevailing geographical setting, developed and under developing
scope, the proposed space plan about Public Outdoor & Recreation activities is as
follows. (The prevailing spaces within Ratnapura Municipal Council Area is limited)
(Map No. 08)
17
Proposed Public Outdoor & Recreation plan for Ratnapura Urban
Development Area
Table No. 03
Serial
No.
Type Extent
(Hectares)
Present Usage Proposed
Usage
Grama
Niladha
ri
Division
01. Mini Parks
MP1
(Children‟s park
and forest)
MP2
(Monarawila
playground)
MP3
(The children‟s
park associate to
Kalu Ganga
0.4
0.8
0.2
Underdeveloped
Is a playground
Live
impermissible
residencies
Mini Parks
Mini Parks
Mini Parks
02. Local Parks
LP1
(Mudduwa
stadium and
children‟s park)
LP2
(Ratnapura new
town indoor
stadium and
playground)
1.6
1.6
Is a playground
Games /
Common
Affairs
Local Parks
Local Parks
03. Linear Parks
Kalu Ganga
reserve
Way Ganga
reserve
Rivulet reserve
Linear Parks
Linear Parks
Linear Parks
The Playgrounds and Children‟s Parks which must be Re-Developed
(The proposed places for public outdoor recreation activities indicate in Map
No. 08)
01. Ratnapura New Town Indoor Stadium – and Playground (1.6 ha)
This playground bounded to the main road must be developed with
infrastructure facilities. It is more appropriate to adopt the transparent
sources for its boundaries and may more suitable to re-develop together with
a children‟s park.
02. Proposed Children‟s Park and Green Forest – (0.4 ha)
Construction of children‟s park and green forest and landscape must be done
as to commensurate to the canal way in the said area.
19
03. The Children‟s Park Bounded to Kalu Ganga (0.2 ha)
This children‟s park maintains under good management and further
suggested by this plan that it must be re-developed.
04. Monarawila Playground - (0.8 ha)
Presently this playground is not using and suggested to mark delimits clearly.
It is a land of the municipal council which has access gates and must be re-
developed with infrastructure facilities.
05. Ratnapura Mudduwa Children‟s Part and Playground – (1.6 ha)
This playground consists with a children‟s park and belongs to the municipal
council. All infrastructure facilities are available in this playground and the
children‟s park also consists with all game equipment.
06. Schools Playgrounds
Presently, the school playgrounds are not using as common playgrounds and
suggested by this plan to give opportunities to use them for common usage
as much as possible.
07. The Pomapakele Natural Swimming Pond and Park
Re-development of this natural park and swimming pond situated in the area
as an attractive place protecting the natural environment and the biological
diversity of the park.
08. Implementation of Linear Parks Concept
The Kalu Ganga is considered as a main river that flows through
Ratnapura municipal council limit. It is suggested by this plan to
develop appropriately the 66 feet river reserve under the “Linear
Park” Concept with objectives of conserving the areas associated to
this river as water reserving areas and suitable to make the river
reserve according to the methodologies that able to walk.
The “Way Ganga” which considers as a branch river of Kalu Ganga
also flows bounded to this municipal limit and there too must be
allocated 15 feet for the reserve and suggested by this plan to develop
suitable places of the said reserve under Linear Parks Concept.
The canal reserve also must be developed as much as possible as
walking areas under the Linear Parks Concept.
20
2.5.2 Conservation Areas
01. Wetlands, Water Retention & Detention Areas (Map No. 09)
Accordingly, it is suggested by this plan to demerge the areas i.e. the
wetlands, cultivated paddy fields, abandoned paddy lands and watery areas
in Ratnapura municipal council domain as “Flood retention & Detention”
areas as to commensurate the prevailing flood disasters. The developments
of places adjoined to these areas must be done in compliance to the relevant
rules, regulations and institutional recommendations.
02. Conservations Sites, Archaeological Sites, Cultural Sites & Religious
Places.
All silvicultures, conserved forests (Muwagama, Angammana) and parks
(Pompakele) in Ratnapura municipal council domain must be conserved and
the religious places, buildings and places that are in archaeological value also
must be conserved.
The Historic Maha Saman Devalaya
Maha Saman Devalaya is a main religious place in Sabaragamuwa
Province and suggest by this plan to conserve it and Pooja Bhoomi
area on historical and archaeological values. This place had been
used by dutches as a strong hold for their war affairs in the period of
Sri Lanka was a colony under the dutch.
Ehelepola Demesne (Walawwa)
Ehelepola Demesne is the place where Ehelepola Adhikaram lived
and presently has developed as a museum park. It is suggested to
conserve this place to protect its historical value and further develop
and establish the museum park.
Dutch Strong Hold
The strong hold which was used by Dutches as their strong hold is
presently used by Gems and Jewellry Authority and this building
bears a historical importance. Further, it is also suggested to conserve
the building situated around, where the Department of Police has
presently established which also used by foreigners, as it bears a
historical importance.
03. Scenic Sites
Many roads in Ratnapura municipal council domain run across scenic sites. While
traveling on these roads, the “Adam‟s Peak” which considered as a world heritage
sacred place scenes attractively. Accordingly, it is suggested to conserve the
identified places in the town and to refrain from granting permission to display
notice boards and control the development works which interrupt to the
attractiveness. A passive recreation is given by this attractiveness.
21
2.6 Environmental Plan for Ratnapura Municipal Council Area
2.6.1 Ratnapura municipal council Area is rich of scenic sites, historical places and
ecologically sensitive areas. Due to slope situation of the land and location of Kalu
Ganga valley, plenty of natural disaster situations occur and it is essential to
conserve and protect the urban environment.
Accordingly, strategies for ecological conservation and disaster management plan to
minimize disasters are suggested by this plan.
Objectives
To protect the ecological equilibrium by introducing a systematic methodology for
natural environment system, land low ecological sensitive area and conservation
areas.
2.6.2 Expected Target of the Disaster Management Plan
1. Conducting the development process as to minimize disasters may occur in
future.
2. Introducing development methods for specially selected zones.
3. Introducing balance land use pattern.
4. Obtaining maximum economic benefits together with ecological
conservation.
5. Direction to a systematic way in urban development.
6. Forming rules and regulations required in urban development including an
excessive value for the residential zones around.
2.6.3 Disaster Management Strategies
1. Minimizing the density in disaster prone areas by implementing the proposed
zoning plan for minimizing disasters.
2. Planning drainage system and wetlands as to resist the instant flood
situations in the town.
3. Implementation of proposed plans through provincial authorities.
4. Identifying landslip tendency areas and introducing methodologies to
minimize landslips.
5. Controlling construction of boundary walls in flood zones.
6. Make arrangements to minimize risk of landslip in slope areas through
drainage construction based on side dam construction and contour lines.
2.6.4 Suggestions Implemented by the Disaster Management Plan
Strategies to Minimize the Risk of Landslip
To minimize damages occurred to the human and properties by well protecting the
landslip tendency areas, to protect future water resource, to protect soil, animal and
plants are expected from these strategies. Also it is expected by implementing these
projects to make stable the physical environment as to face in a disaster situation.
23
1. Minimizing of landslip process by applying grass sods on a land consists
with hillside surface.
2. Applying of mechanisms to absorb surface water in order to control landslips
and floods.
3. Protecting the soil by constructing of side dams and contour drainages.
24
4. Development of mountain areas with an environment friend manner as to
minimize the weaknesses occurred in embankments and collapsing slopes.
5. Creating building plans and introducing regulations as to resist the landslip
situations.
Strategies to Minimize Risk of Floods
Minimizing the risk of disasters and securing human settlements through an
environment friend process is expected by these strategies. Minimizing of streaming
surface water is a key objective and maintaining of an optimum water capacity in
rivers by minimizing the accumulative water through a development methodology of
streaming water ways is expected by this project.
25
1. Establishment of public entertaining areas by plating in rivers, canals and
rivulets associated areas and constructing landscape paths.
River Reservation of Kalu Ganga
2. Creating of strip parks in central town areas.
3. Creating of multiple plant zones, creating strip parks in both sides of canals,
rivers and roads and creating of inter zone grass strips.
River Reservation of Kalu Ganga
26
4. Creating of covering zones, planting grass sods and planting environment
friend trees in both sides of the river bank. (bamboo trees, kumbuk trees)
Preservation of Katugasella Ela Reservation
5. Creating of building plans as to resist the flood situations and introducing of
regulations.
27
Authorized Utilizations According to Flood Disaster Zones
Zone Approved Utilizations Unauthorized
Utilizations
Other Requirements
Hig
h R
isk
y
Residential uses with a large
allotment (minimum extent
of an allotment is 20-40
perches).
Must be minimum 2 floors
for commercial activities.
Hotel parks, water retention
areas, plantations, forest
conservation parks, natural
water-ways, hot beds, parks,
open lands, playgrounds.
Industries, education
institutions, public
gathering places,
financial activities,
animal husbandry
All constructions must
be done under safety
steps.
Special sewage
methods must be
introduced.
Permission from
relevant institutions
must be obtained.
- U.D.A.
- Disaster
Management
Center.
- National Buildings
Research
Organization.
Development of
adequate vehicle
parking facilities and
infrastructure
facilities.
Granting permission
for temporary
buildings.
28
Zone Approved Utilizations Unauthorized
Utilizations
Other Requirements
Med
ium
Ris
ky Z
on
e
Residential activities.
Industrial activities, parks,
playgrounds.
Open lands and for leisure
and recreation activities.
Plantation activities.
Institutional activities.
Communal development
activities.
Public gathering center.
Financial activities.
1. Special sewage and
refinery methods
must be introduced.
2. Permission from
relevant institutions
must be obtained.
- U.D.A.
- Disaster
Management
Center.
- National Buildings
Research Institute.
3. Adequate vehicle
parking facilities and
infrastructure
facilities must be
provided (by way of
not victimizing to
disasters)
29
Zone Approved Utilizations Unauthorized
Utilizations
Other Requirements
Lo
w R
isk
y Z
one
Residential (less land
coverage)
Industries.
Providing space for low rise
buildings.
Public gathering places.
Government and Semi-
Government buildings.
Administrative complexes,
education and training
institutions, cultural centers
and religious places,
community halls, museums
and vehicle parking complex.
Vehicle parking places.
Cultivating activities,
plantation industry.
Power generation.
1. Sewage and refinery
methods must be
introduced.
2. Recommendations from
Provincial Institutions
and National Buildings
Research Organization
must be obtained.
3. Adequate vehicle parking
facilities and
infrastructure facilities
must be provided
30
Zone Approved Utilizations Unauthorized
Utilizations
Other Requirements
Hig
h R
isk
Parks, silvicultures, forest
conservation parks, hot beds
parks, open lands,
playgrounds.
Recommended arable
farming for slopes.
Residential activities
recommended by Urban
Development Authority and
National Building Research
Institute.
Plantation activities done
according to contour lines.
Temporary buildings.
Industries, education
institutions, public
gathering places,
places where financial
activities are done,
animal breeding
centers.
All constructions must
be done in compliance
to the slope inclination
and other safety steps.
Special sewage
refinery methods must
be introduced.
Permission from
relevant institutions
must be obtained.
- U.D.A.
- Disaster
Management
Center.
- National Buildings
Research Institute.
Adequate vehicle
parking facilities and
infrastructure facilities
must be provided
31
Zone Approved Utilizations Unauthorized
Utilizations
Other Requirements
Med
ium
Ris
ky Z
one
Residential activities.
Industrial activities, parks,
playgrounds.
Open Spaces and for leisure
and recreation activities.
Plantation activities.
Institutional activities.
Community development
activities.
Public gathering center.
Financial activities.
Multiple buildings
recommended according to
the weight.
Plantations done according
to contour line
methodologies.
1. All construction works
must be done in
compliance to the
relevant land
inclinations under
other safety steps.
2. Special sewage and
refinery methods must
be introduced.
3. Permission from
relevant institutions
must be obtained.
- U.D.A.
- Disaster
Management
Center.
- National Buildings
Research
organization.
4. Adequate vehicle
parking facilities and
infrastructure
facilities must be
provided (by way of
not vulnerability to
disasters)
5. Plantations done
according to the
contour line
methodologies.
32
Zone Approved Utilizations Unauthorized
Utilizations
Other Requirements
Lo
w R
isk
y Z
one
Residential (less land
coverage)
Industries.
Providing space for tall
buildings (towers).
Public gathering places.
Government and Semi-
Government buildings.
Administrative complexes,
education and training
institutions, cultural centers
and religious places,
community halls, museums
and vehicle parking complex.
Vehicle parking places.
Cultivating activities,
plantation industry.
Power generation.
1. All constructions must be
done based on contour
lines.
2. All plantation must be
done according to the
contour line methodology
and under other safety
steps.
3. Sewage and refinery
methods must be
introduced.
4. Recommendations from
Provincial Institutions
and National Buildings
Research Center must be
obtained.
5. Adequate vehicle parking
facilities must be
provided
33
CHAPTER 03
Regulations
Regulate the development to achieve objectives in Ratnapura Urban Development
Plan and Establishment of land Use Zones for 2030
3.1 General Zoning Regulations
3.1.1 If any place of property has been named only for a special usage by the zoning plan
(Map No. 03), the said place or property must be used only for the said usage.
3.1.2 In case any construction is carried out in each zone named by the zoning plan, the
maximum sites ratio that can be used for construction must be as indicated by
annexure – VI.
3.1.3 If any place or property has not been named for any special usage, the permitted
usages in the zone where the said usage is situated must not be interrupted according
to the zoning plan.
3.1.4 Except a usage approved by a development license , any place or a building must not
be taken for any usage by any person.
3.1.5 Any action that may cause to an alteration, renovation, demolition deface or a
damage to a building stated in Annexure-V must not be taken without approval or
permission from the Urban Development Authority.
3.1.6 If any person makes an application to construct buildings in commercial and
administrative zones, the said buildings must be constructed according to the
instructions given by the Urban Development Authority with regard to its exterior
view.
3.1.7 According to the above instructions, the Urban Development Authority can order to
change or modernize about the height, color, materials used to construct and
architectural creations of prevailing buildings are in 3.1.6 above.
3.1.8 The boundaries of buildings in the street adjoined to any place or a land must be in
compliance to the Annexure-II.
3.1.9 The building line for a place adjoined to any common foot-path, steps must be not
less than 2.0 meters from center of the foot-path.
3.1.10 The ground floor of buildings situated adjoining to main roads in the commercial
zone must not be used for residential activities except in such occasions to which the
permission from Urban Development Authority has been received.
3.1.11 The water ways conservation of any place or an allotment situated adjoining to a
water way must be in compliance to the Annexure-III.
34
3.1.12 If any application is made to construct a religious place or to change any building‟s
usage for religious activities, the applicant must confirm that there is no objection
from public residing within the area of 0.5 km. radius from the relevant religious
place. (at least 2/3 from the total number of residents must be refused). This order
is relevant for various types of religious statues, crosses and other signs that are
permanently constructed in any place.
3.1.13 The permanent name boards or advertisements must be fixed perpendicularly to the
street or as to no interruption will occur to the building‟s exterior view. The
permanent name boards or advertisements must be installed perpendicularly to the
land by 3.5 meters height. Installation of advertisements or name boards in
boundary walls, boarders by way of occurring vehicle congestions, vehicle accidents
is prohibited.
3.1.14 If any property or an allotment is situated within 500 meters from Sabaragamuwa
Maha Saman Devala Bhoomiya (land), no any meat or flesh shop, betting or gaming
house or liquor shop shall carried out within the said property of allotment.
3.1.15 Mining works that are carried on by any person in permitted zones for mining must
be in compliance to the requirements mentioned in Annexure-VII. Further,
permission must not be granted by any institution for mining without settlement of
primary plans obtained from the Authority.
3.1.16 The permissible mining and finalizing of their works must be in compliance to the
conditions in relevant license issued by relevant institutions.
3.1.17 The maximum possible limit of propagating any building or a construction in any
land is 30.0 meters. The allotment comes over after every 30 meters shall leave for
a fire gap. The power to grant permission to use this open neck of land till adopts it
as a common neck of land reserves with Urban Development Authority.
3.1.18 All constructions that are permitted in landslip risk areas must be in compliance to
the Annexure No. IX.
3.2 Planning Regulations and Zoning Conditions
Planning Regulations
3.2.1 Every allotment, houses and landed properties will be as a part of a zone indicated in
the plan of zoning plan (Map No. 3). Zones are as follows.
i. Law density residential zone.
ii. High density residential zone.
iii. Mixed residential zone.
iv. Administrative zone.
v. Commercial zone.
vi. Pooja Bhoomi zone.
vii. Ecological sensitive zone.
viii. Special conservation zone.
35
3.2.2 In an occasion that any area consists with development areas which the Authority
shall seem fit may define as a special development area as follows.
i. Conservation areas (natural reserves, forest areas and architectural value
areas and buildings, historical, archaeological and aesthetic areas).
ii. Central town area.
iii. Special housing project areas or special project areas.
iv. Landslip areas and landslip tendency areas.
3.2.3 The authority may exclusively enact conditions and indicate requirements in respect
of using above areas to construct any type of building.
3.2.4 The areas allocated for any special usage, utilizing zones described under section
3.2.1 and the special development areas described in section 3.2.2 will separately
indicated in suitable dimensions by applying appropriate lines, colors or any other
signs.
3.2.5 Zonal boundaries described in the development plan are often based on prevailing
roads, by-roads and water ways and in circumstances where such boundaries are not
described, then may adopt the boundaries relating to properties described in town
surveying maps.
3.2.6 In the circumstances where any land area has indicated as to fall among two zones,
the classification zones for the land area are determined and it is the zones belong to
main accesses of the said allotment. However, in the circumstances where any
zoning boundary has confirmed by length and width, the classification zone of said
allotments is determined according to the above special limits.
3.2.7 Descriptions about usages within named zones to which the approval can be granted
must be in compliance to the following conditions.
i. The said usage must be in compliance to area‟s nature, must not make
interruption or contrary effect to facilities available in the area, must not
make interruption to the privacy and must not occur environment pollution or
any other nature of obstacle.
ii. Such usage must not interrupt to the vehicle movement and must be able to
provide vehicle parking facilities within the said land.
iii. Land extent must be sufficient for proposed usage, ability to obtain
infrastructure facilities, availability of sufficient arrangements to provide
protection from fire and natural disasters.
iv. Must be in compliance to the conserves (roads, rivers, canals & rivulets)
indicated in Annexure – II and III.
v. Must be in compliance to the conditions of dangerous and unsafe business
activities indicated in Annexure-IV.
vi. Must be in compliance to the conditions relevant to landslip (high risk) areas
indicated in Annexure-IX.
36
Zoning Conditions
3.2.8 High Density Residential Zones
3.2.8.1 Approval is granted for following usages within High Density Residential Zone.
i. Residential buildings.
ii. Primary schools, education institutions and communal affairs institutions.
iii. Medical treatment centers not exceeding 150 m2
iv. Religious places.
v. Professional offices not exceeding 100 m2
vi. Commercial buildings not exceeding 100 m2
vii. Canteens not exceeding 150 m2
viii. Government or private office buildings not exceeding 100 m2
ix. Social and cultural places.
x. Parks and playgrounds.
xi. Indoor stadiums and recreation activity institutions.
xii. Indoor industries must not exceed 100 m2 and number of employees 10. If
machineries are used, the capacity must not exceed 5 horse powers and the
maximum sound level for primary residential areas must be 55 decibel in day
time and 45 in night time as defined by the Central Environment Authority.
xiii. Mining activities.
xiv. Buildings (Following requirements need to fulfill when constructing
buildings within the Coastal Zone)
- 45 perches land extent
- 66% plot coverage
- 2.5 FAR
N.B.
Approval is being given only for the actions related to the Tourism Industry.
3.2.8.2 If any allotment is situated facing to an „A‟ class main road, the minimum extent of
the land subject for development in order to consider granting permission for usages
described in No. II to XII above-mentioned 3.2.8.1 must be 250 m2 (10 perches) and
width of the land obverse must be minimum 6 meters (20 feet).
3.2.8.3 Vehicle parking facilities within the relevant land must be provided in respect of
every development which is being considered for approval within this zone.
3.2.8.4 Construction of buildings described in 3.2.8.1 above must be in compliance to the
land inclination conditions as stated in Annexure-I and the maximum site ratio as
stated in Annexure-VI.
3.2.8.5 Construction of buildings described in 3.2.8.1 above must be in compliance to the
conditions stated in Annexure-IX.
37
3.2.9 Low Density Residential Zones
3.2.9.1 Approval is granted for following usages within the low density residential zones.
i. The usages contained in (i), (iv), (v), (ix), (x) of section 3.2.8.1 allowed
within the law density residential zone.
ii. Medical treatment centers not exceeding 100 m2
iii. Primary schools, communal centers and such other activities,
iv. Indoor commercial activities not exceeding 25 m2
3.2.9.2 The conditions stated in 3.2.8.2 and 3.2.8.3 described under high density residential
zone of 3.2.8 above shall also effect for this zone.
3.2.9.3 Construction of all buildings described in 3.2.9.1 above must be in compliance to the
land inclination conditions stated in Annexure-I and the maximum site ratio stated in
Annexure-VI.
3.2.9.4 Construction of all buildings described in 3.2.9.1 above must be in compliance to
Annexure-IX.
3.2.10 Mixed Residential Zones
2.3.10.1 Approval is given for following usages within mixed residential zone.
i. All usages granted within the high density residential zone described
in 3.2.9.1 above.
ii. Small scale industries (Must be under the maximum sound level for
mixed residential zones recommended by the Central Environment
Authority and extent of the land subject to use must not exceed
300 m2)
iii. Wholesale activities.
iv. Hotels, canteens and lodgings.
v. Government buildings.
vi. Medical services centers.
vii. Fuel stations
viii. Mining activities
3.2.10.2 The Authority may enact limits and conditions to stop or minimize water, air
and environment pollution while granting permission for any type of usage
in the area, to avoid the vibration occurred by industries and to avoid the
obstacles occurred by fire and other disasters.
3.2.10.3 While taking access for above usages by Colombo-Badulla and Ratnapura-
Panadura road, provision of vehicle parking facilities within the relevant land
is a must.
3.2.10.4 Construction of buildings described in 3.2.10.1 above, the maximum site
inclination must be in compliance to Annexure-VI.
38
3.2.11 Commercial Zone
3.2.11.1 Permission is granted for following usages within this zone.
i. Commercial institutions / shops / showrooms / common and
supermarkets.
ii. Hotels, guest houses, lodgings and canteens.
iii. Banks and financial institutions.
iv. Cinemas, areas allocated for leisure and recreations and clubs.
v. Medical treatment centers.
vi. Professional offices / commercial offices.
vii. Fuel stations and vehicle parking facilities.
viii. Residential activities.
ix. Presses not exceeding 500 sq.ft.
x. Motor vehicle repairing places not exceeding 300 sq.ft.
xi. Gem cutting and polishing industries.
3.2.11.2 Construction of buildings described in 3.2.11.1 above, the maximum site ratio
must be in compliance to Annexure-IV.
3.2.12 Administrative Zone
3.2.12.1 Permission is granted for following usages within Government and Semi
Government zone.
i. Public gathering places.
ii. Common / Government / Semi Government institution buildings.
iii. Education institutions and training institutions.
iv. Public gathering halls, cultural centers, religious buildings.
v. Parks, playgrounds, open areas and leisure and recreation activities.
vi. Libraries, museums and showrooms.
vii. Vehicle parks and vehicle park complexes.
viii. Canteens not exceeding 150 m2
ix. Canteens not exceeding 350 m2
x. Residential buildings.
3.2.12.2 Construction of buildings described in 3.2.12.1 above, the maximum site ration
must be in compliance to Annexure VI.
3.2.13 Pooja Bhoomi Zone
3.2.13.1 Permission is granted for following usages within this zone.
i. Religious buildings.
ii. Public gathering places.
iii. Residential buildings relevant to religious activities.
iv. Open areas.
v. Common and religious activities.
3.2.13.2 Construction of buildings described in 3.2.13.1 above must be in compliance to
the site ratio stated in Annexure-VI.
39
3.2.14 Ecological Sensitive Zone
3.2.14.1 Permission is granted for following usages within this zone.
i. Natural parks / forest floors.
ii. Conserved areas.
iii. Natural roads.
iv. Agriculture plantations.
v. Hot beds.
vi. Agriculture and floral parks.
vii. Open air areas / playgrounds.
viii. Mining activities only in paddy fields and wetlands.
ix. Leisure and recreation facilities.
3.2.14.2 No approval will be granted to any construction which is not incidental to the
prevailing agriculture and forest lands / lands low pattern.
3.2.14.3 In addition to above usages, the Urban Development Authority reserves power to
approve any usage which may not cause for any obstacle.
3.2.15 Special Conserved Zone
3.2.15.1 If all lands situated in this zone,
i. have already victimized for landslips or
ii. are in a position to face for landslips or
iii. as the land slopes are 600 or above, no permissions will be granted for any
construction and only following usages will be permitted.
1. Natural forests
2. Silvicultures
40
Planning and Building Regulations
Part I
General
Orders
1. Introduction
These regulations known as Planning & building Regulations for Ratnapura
Municipal Council Area and will come into operation with effect from
………………..2014.
2. Submission of Plans for Approval
(i) Under Section 8 of Urban Development Authority Act (Amendment) No. 4
of 1982, every application to obtain a permit for any development activity
must be submitted by relevant “A” and “B” forms specified under schedule
01 of this enactments and the fee stated in schedule 05 accompanied by the
fees specified.
(ii) Every plan that have been submitted under this regulation must be signed by
a qualified person except for following ,
(a) Additions and alterations not exceeding 50 sq.ft. which doesn‟t effect
to the building‟s structure.
(b) Single or two storey residential buildings not exceeding 250 sq.ft. of
which walls or columns are not situation on the land boundary.
(c) Single or two storey non-residential buildings not exceeding 150
sq.ft. of which walls or columns are not situated on the land
boundary.
(iii) The Authority or an Authorized officer of the Authority must satisfy about
correctness and clearness of the plans submitted under the Orders in (ii)
above.
(iv) Be signed by the owner of the site.
(v) Be submitted in triplicate.
3. (i) The Authority may, where it deems necessary require the submission of
additional copies of the plans submitted under the Order in 2(ii) upon
considered as required by the Authority.
(ii) In addition to the plans and details mentioned in the application, the
Authority may order to submit additional details and plans that may
considered as required by the Authority.
41
4. The following details must be contained in all plans that are submitted for the
purpose of obtaining a developing permit in respect to any specific development
activity..
(i) In such circumstance of a developing activity where any building work has
not been included or it is restricted to land development.
a. A location plan of the site in relation to the adjoining streets to a
scale of not less than 1:4000
b. A survey plan drawn in a scale not less than 1:1000 in which
including following details must be provided.
i. The location of the site including the figured dimensions of
buildings available in any.
ii. Scale of the plan, the North point and assessment numbers of
adjoining lots or buildings.
iii. The access roads to the site, their widths.
iv. All prevailing drainages and water ways ; and
v. The contour or spot levels of the site and levels on the street
or street in front of the site, where necessary.
c. A detailed blocking out plan drawn in to a scale not less than 1:1000
indicating the proposed sub divisions, dimension and all proposed
streets‟ direction, distance, width and open spaces and space for other
amenities and the purpose of all sites intended to use.
(ii) The following plans must be submitted where building work is involved in
the development activity.
a. A sketch plan of the surrounding area as to aware sufficiently about
the site where the building is being constructed.
b. An approved blocking out plan drawn in a scale not less than 1:1000.
c. A site plan for each site indicating following facts drown in a scale of
1:100 must be submitted except for a building of more than 1000 m2
If it is more than as stated above, 1:200 scale may be used.
i. Figured dimensions of the building, rooms and other parts
and the purpose all rooms and parts of the building are
intended to use.
ii. The positions & dimensions of all doors, windows and other
counters must be indicated.
42
iii. The position of all sanitary appliances and the way of
connecting them to the sewer lines must be indicated.
iv. fire escapes must be indicated ;
v. Distance to aerial electricity supply lines from the building
must be indicated.
vi. Material type and their specifications intended to use for
building‟s wall or super structure, floor slabs and roof‟s
structure must be indicated ;
d. Drawing indicating the cross and longitudinal sections along suitable
lines with following details.
i. Thickness of building‟s all walls, floors , roofs, foundations,
beams and other relevant parts;
ii. Position and dimensions of building‟s doors, windows or
other openings and length, width, height of each storey,
ceiling height and the levels of the building in relation to
existing ground or street level and clear distances between the
site boundary and the external walls of the building.
e. Front and side elevations of the building showing elevations of every
existing building within the site showing its height, floor level and
other external visible features;
f. Means of disposal of rain water :-
g. Whether the building is to be centrally air conditioned ; and
h. Such other particulars or information relating to the building as the
Authority may require in order to satisfy itself as to the exact nature
of the development activity envisaged ;
5. All plans including proposals must be clearly prepared and submitted in black color,
newly added construction works in red color and all parts and signs of any
prevailing building expected to retain or remove in dotted lines, drawn in ink or re-
produced in print neatly and accurately.
6. Types of Buildings
For the purpose of these orders, the buildings must be classified as follows.
Type „A‟ - means any building consisting of five or more floors including the
ground floor or any building the height of which exceeds fifteen meters above the
adjoining street
43
Type “B” - Comprises any building, not being a high-rise building which consist of
i. Not more than four floors, including the ground floor, where a wall or
column is situated on the boundary;
ii. A basement - roof, foundations, beams and other related parts of the
building;
iii. A pile or raft foundation;
iv. A roof span exceeding ten meters;
v. A place of public assembly or a public building;
vi. A building which is wind sensitive such as warehouses and factory; and
vii. Any other type of building not covered under categories A and C;
Type „C‟ - Shall comprises of the following Sub Categories -
(a) C I - (i) Any building which is used for residential purposes
and shall not exceed Five Hundred (500) sq.m. in
extent which does not fall under Category “B”.
(ii) Any building which is used for non residential purpose
and does not exceed Three Hundred (300) sq.m. in
extent which does not fall under Category “B”.
(b) C II - (i) Any building which is used for residential purpose
and does not exceed Four Hundred (400) sq.m. in
extent which does not fall under Category “B”.
(ii) Any building which is used for non residential purpose
and does not exceed Two Hundred (200) sq.m. which
does not fall under Category “B”.
(c) C III - (i) Any building which is used for residential purpose and
does not exceed Two Hundred (200) sq.m. in extent
and is not covered under Category “B”.
(ii) Any building which is used for non residential purpose
and does not exceed Hundred (100) sq.m. which is not
covered under Category “B”.
7. Submission of Architectural and Service Plans
(1) An application shall, prior to the commencement of any building works in
respect of all buildings other than those buildings falling within sub Category
C III of Category C, submit detailed structural plans along with the design
calculations of the proposed building. such plan shall be signed by a
qualified person.
44
(2) The detailed structural plans along with the design calculations of the
proposed building, signed by a qualified person shall -
(a) In relation to all buildings falling within Category A and Category B
of regulation 6; and
(b) In relation to buildings falling within Sub category C I and C II of
Category C of regulation 6, if required to do so by the Authority,
Shall consist of the following –
(i) A statement indicating in clear and precise language, the manner in
which the superimposed load for which each floor system or part
thereof has been designed;
(ii) The results of any soil tests carried out, the calculations for
determination of soil bearing capacity and earth boring
investigations; and
(iii) The type or types of the foundation which is recommended to be
used;
(3) Where any air conditioning or mechanical ventilation system shall be
installed in a building or part thereof or where any such system therein shall
be extended or altered the layout and detailed plans of the installation,
extension or alteration to be carried out, with information pertaining to
capacities, shall be submitted by a qualified person to the Authority for
approval along with plans of the building in which the system shall be
installed, extended or altered.
(4) The applicant shall submit before commencing building work in respect of
all buildings mentioned in Category A and Category B and if required by the
Authority in the case of building falling within Sub Category C I and C II of
Category C, service plans relating to water supply, sewerage, drainage and
rain water harvesting. Such service plan shall be prepared and signed by a
qualified person.
(5) The applicant shall submit before commencing building work in respect of
all buildings mentioned in Category A and Category B and if required by the
Authority in the case of buildings in falling within Sub Category C I and C II
of Category C, service plans relating to Electricity prepared and signed by a
qualified person.
45
8. Preliminary Planning Clearance and approval of Plans
(i) According to Form “C” of Schedule-I of these Orders, Preliminary planning
clearance shall be in writing and may include such restrictions and conditions
as may be imposed. This is a temporary permission given that any
development activity is possible to do in the relevant place. After submission
of the detailed plans for a determined task by the applicant, the due approval
for the said task must be obtained from the Authority.
(ii) It shall be valid for a period of one year
(iii) The preliminary planning clearance will not constitute a permit and shall not
entitle the applicant or any person to commence or carry out any
Development Activity whatsoever.
(iv) Every development permit granted shall be in writing and shall be subject to
the restrictions and conditions set out therein.
(v) The Authority may on application and payment of prescribed fee extend the
validity of the permit for a further period of not exceeding two years, If it is
satisfied that the development activity referred to in the permit has been
commenced but not been completed due to unforeseen circumstances.,
9. Appeals against Refusal
Any person aggrieved by the decision of the Authority refusing to issue a permit,
may within thirty days of receiving notice of such refusal appeal to the Minister
10. Development to be in Conformity with the Permit
(i) No development activity shall be commenced or carried out in contravention
of the Development Permit.
(ii) The Authority may cancel the development permit due to any reason stated
below :-
a. A breach of a term or condition of the permit
b. A contravention of the provisions in these regulations
c. A misrepresentation of facts in the application, plans or other
documents submitted by the applicant, or
d. Failure to submit plans and other particulars under regulation 7
46
Part II
Planning Conditions
11. Suitability of the site:
(i) No development activity shall be carried out in respect of,
a. site which has been filled up with any substance impregnated with
faucal, animal or vegetable matter unless such substance has been
removed and the site cleared completely, or the whole ground surface
has been rendered innocuous and covered with a layer of earth or any
other suitable material which is at least thirty centimeters thick.
b. Lands associated to mines, flood or landslip trend sites. If such sites
are expected to use for any development process or to construct any
building, a recognized certificate about suitability of the land issued
by National Buildings Research Organization must be obtained.
(ii) If any site has been located to the prevailing cemetery, development works in
such place must be done in terms of the Cemetery Ordinance No. 089 of
1899.
12. Use of Site
No site or building whether existing or to be constructed be used for any purpose
other than the purpose for which approval has been granted.
13. Floor Area Ratio (F.A.R.)
(i) The maximum Floor Area ratio for any site shall be in accordance with the
specifications in Annexure-I and VI of the Volume-II of Ratnapura urban
development plan.
(ii) In addition to Floor Area Ratio (FAR) granted as stated above, a basement to
be used for parking and for the location of air conditioning plant or generator
or other service machinery may be permitted. As stated in Schedule 05 of
this Order, If a permanent parking space is provided at the level of any floor
in a building, such parking space shall be excluded from the calculations of
the floor area ratio.
14. Access
(i) No site or lot abutting a street less than 9 (nine) meters in width shall be used
for non-residential use or construction of any building for such use, except
the provisions contained under Section 14(ii).
47
(ii) a. Every street meant to serve dwelling units shall be in conformity with
the specifications set out in in Form “A” of Schedule 04 here.
However, the minimum width of the street when providing access to
a number of houses more than twenty units in the low density
residential zone of Ratnapura urban development plan must be Six
meters.
b. Permission may be granted to construct a street less than Nine (9)
meters in width to passage for one or more allotments where any non-
residential building is constructed and such constructions must be in
compliance to the specifications contained in Form “B” of Schedule
However if the Chairman is of opinion that undue hardship will be
caused to a person, in the case of residential use of a lot if the
minimum access requirements for dwelling house as stipulated in Schedule 04 are to be complied with the minimum width of access
may be reduced by not more than two meters on the recommendation
of the Head of Local Authority and in consultation with the Planning
Committee subject to the following;
i. A minimum width of three meters is available for access
ii This reduction will not apply in case new sub-divisions
ii. The area has a semi-urban character
(iii) All streets described in “B” above must be connected to a common street in a
width not exceeding Nine (9) meters. Such person who possess a private
street must have a right of way to connects with a common street in a width
not exceeding 9 (Nine) meters.
(iv) A turning circle in a diameter of not exceeding Nine (9) meters must have
arranged at the end of every street in a width and length not exceeding Nine
(9) meters and Thirty (30) meters respectively.
15. Specifications as to Lots
(i) The minimum area and width of allotments for any constructions in
residential zones where no high- rise buildings must be in compliance to the
specifications related to plots shall be in accordance with Annexure-I of
Volume-II of the urban development plan.
(ii) Every lot or site which abuts on to a dead end street may have a frontage less
than the width given under 15(i) above and it must Three (3.0) meters or
above.
(iii) If other requirements relevant to a building construction in a land where not
adjoined to an “A” grade or “B” grade main road has been fulfilled, the
Authority may relax the requirements pertained to the extent of a land and
the width of an allotment.
48
16. Building Heights
(i) The height of any resident building situated in residential zones of Ratnapura
urban development plan must be in compliance to Annexure-1 of Volume-II
and the maximum height of a building constructed in any prevailing land of
Six (6.0) meters width or below and less than One Hundred Fifty (150) sq.m.
in extent must be Seven and Half (7.5) meters or not exceeding two floors
unless the Authority determines in other way.
(ii) If the lot is situated in a corner, the height of the building shall be regulated
by the wider of such streets so far as it abuts or will abut on the narrower
street to a depth of twenty (20) meters from the wider street.
(iii) In measuring the height under these regulations the lift or motor room not
exceeding a height of six (6) meters and not exceeding fifty five (55) square
meters in extent, or a staircase room not exceeding a height of five (5) meters
and not exceeding 25 square meters in extent or a water tank not exceeding a
height of 1.5 meters shall be ignored.
(iv) If any land or a property is located facing to Kalu Ganga, the height of
buildings constructed therein must be in compliance to the conditions
contained in Volume-II of Ratnapura urban development plan.
17. Street Lines and Building Lines
(i) When the street lines for any street under any Act or any conditions have
already been determined, the street line of relevant street or road must be in
compliance to the said Orders.
(ii) The building line for every lot abutting the street shall be in conformity with
the specifications and categories set out in Annexure-II of Volume-II of
Ratnapura urban development plan.
(iii) No building shall extend beyond the building line provided that balconies,
sunshades or eaves, not exceeding 01 meter in width may be permitted
between the building line and the street line and a fence or boundary wall not
exceeding 02 meter in height may be permitted between the building line and
the street line.
(iv) Any street line or a building line which has been approved or sanctioned by
Ratnapura urban council must not be changed without Authority‟s approval.
18. Subdivision of Lands
(i) a. No parcel of land or lot destined or proposed for any use other than
agriculture or horticulture shall be sub divided unless a plan relating
to such sub-division has been approved by the Authority.
b. A person whomsoever determines to subdivide a land must submit an
application to the Authority in compliance to the conditions
contained in Order-4.
49
(ii) The Authority can order to the applicant to make a little change of a plan
submitted to subdivide a land as the Authority considers. The site must be
subdivided only after obtaining the approval from the Authority.
(iii) The minimum extent and width of allotments must be in compliance to the
provisions contained in Order-15.
(iv) The open space, illumination, ventilation and other requirements relevant to
an existing building in the said site must not subdivide less than the amounts
prescribed by these orders.
(v) The subdivided lands must not be used for another task except the task
approved.
19. (i) Every allotment of a subdivision must be adjoined to an existing or proposed
street or adjoined to a street stated in Order-14.
(ii) The minimum width of the land allocated for vehicle transportation in streets
must be as approved by the Authority. But the streets up to 9 meters and
above 9 meters must be not less than 3.0 meters and 5 meters respectively.
20. (i) If the land or allotment subject to subdivision is more than 1.0 hectare, a
portion in extent of not less than Ten percent from the land or allotment must
be allocated to use for communal recreation activities and open air areas from
suitable places after leaving streets.
(a) If minimum extent of the land in a subdivision for commercial and
industrial purpose is not less than 2.024 m2 (80 perches) and all
roads‟ width is not less than 9 meters, the said land can be further
subdivided under following conditions without leaving Ten percent
from the land to use for open air areas –
i. Allocate 10 percent from the land subject to subdivide
Or
ii. Deposit 10 percent of the land‟s (subject to subdivide)
marketing value with relevant Provincial Institution.
(b) In subdividing the residential lands, if the minimum extent of
subdivided land is not less than 1.012 m2 (40 perches) and the
development process has been limited as Two housing units
constructed in One allotment, the subdivisions can be done without
leaving open air areas i.e. 10 percent from the land. But in such
occasion that the said subdivided land is further subdivided or
constructed more than Two housing units in One allotment, 10
percent from the marketing value of the said subdivided or developed
land must be deposited with the relevant Provincial Institution.
50
(c) In such circumstances that the land proposed to subdivide is a lake,
situated within 0.5 km. from a common area like a playground, the
said open air area‟s extent is above 4,047 m2 (One acre), instead of
physically allocating an open area in the said land, the marketing
value of the site required for an open air area must be deposited with
the relevant Provincial Institution if the developer is ordered by the
Authority.
(d) In such circumstances that extent of the land required for open air
area in a subdivision is not exceeding 506 m2 (20 perches) or the
developer ordered by the relevant Provincial Institution (with
Chairman‟s approval of Urban Development Authority) to deposit the
marketing value of the area required for subdivision, the said
developer must deposit the marketing value of said area with the
relevant Provincial Institution instead of physically allocating such
open air area
(e) In such circumstances that unauthorized land subdivisions due to
non-allocating of 10 percent open air area, permission may be granted
for further subdivision or to develop each allotment under depositing
10 percent of the allotment‟s marketing value or allocating 10 percent
of the land subject to develop or subdivide.
(ii) All areas allocated as above must be transferred to the Authority with free of
all charges.
21. No permission will be granted to use, sell or construct buildings in any allotment of
a subdivision unless they are developed by marking streets, opening to full width
with common task organizations up to the Authority‟s satisfaction.
22. Layout Plans for Flats and Housing Units
(i) According to the development plan, construction of flats or housing units or
other combined schemes must be approved by the Authority.
23. Covered Areas around the Buildings
The maximum land coverage can be allowed for residential activities must be in
compliance to the conditions contained in Annexure-1, Volume-II of Ratnapura
Urban Development Plan. In the zones except above must be 66 2/3% for residential
usage and 80% for commercial and other usages.
24. (i) An open space not less than 3 meters spread to downward between the
building‟s and land boundaries must be left for all building‟s back side as its
fully owned open space unless any building‟s back side is situated adjoining
to a street in 6 meters width.
However, in such circumstance that the said building consists with ground
floor and first floor and not decided for further construction of floors, the
said back side open space‟s width can be reduced up to 2.5 meters.
51
(ii) For the purpose of this Order, the building‟s back side must be considered as
the building‟s ultimate surface located from the street situated close to the
said building.
However, if the building is located adjoining to one street or more, the
building‟s ultimate surface from the widest street (from said streets) must be
considered as the building‟s back side unless the Authority determines by
other way.
(iii) Sun shades in width of less than One (1) meter or whatever buildings without
overhanging loggias must not be constructed in the aforesaid open area.
(iv) Regarding the irregular shape sites where an open space (consists with
building‟s total width) cannot be allocated from the building‟s back side, the
Authority may order to leave back side open space after taking into
consideration of circumstantial relevant to each occasion as the Authority
shall seem fit.
(v) Regarding the buildings implied to allocate open space for the purpose of
access, building‟s maintenance or separation of a building from adjoining
properties, the width of such open spaces must not be less than 1.5 meters by
whatever reason.
25. Additional Requirements for High-Rise Buildings
A site proposed to construct a high-rise building must fulfill the following
requirements.
a. If the site‟s extent doesn‟t exceed 1000 m2 and the site‟s shortest side‟s
length must be at least 20 meters.
b. The site must be located adjoining to a street not less than 12 meters in
width.
c. Provision of a detailed technical report (about soil) regarding the
affordability of site‟s soil and as to no interruptions have been occurred by
mining.
26. The Authority may grant permission to construct high-rise buildings in any site
stated above, if the Authority satisfies about following facts.
a. Must not occur interruption to the facilities provided in the area around or
damage to the conformity by the said building:
b. Must not create difficulties or problems to the vehicle movement due to the
building.
c. Must confirm that sufficient measures have been arranged for water supply,
garbage disposal, sewage and electricity supply and to safeguard from fire
and other disasters and vehicle parking.
52
27. (i) Maximum height of the building must not be exceeded doubled of the
horizontal distance between any floor of the said building and adjoining
street‟s remote edge.
(ii) If the allotment is situated in a corner, the building‟s height is controlled only
by the wider street i.e. up to 25 meters overhanging distance from wider to
narrow street.
28. (i) Must have a minimum open air area at least from one side of the building
(not from front or back side) i.e. ¼ from the building‟s height or 5.5 meters
(the less value distance) up to the sites boundaries.
(ii) An open air area (fully spread to downward from the building) equivalent to
a distance of ¼ from the building‟s height must have for every building‟s
back side.
(iii) Under these orders, the required open air areas must be fully owned to the
building. However, if there is any adjoining street spreads (not exceeding 6
meters in width) to the building‟s back side‟s total length, the open air area‟s
(which belongs to the said building) width can be reduced by the amount
equivalent to said width.
(iv) The total extent of lands fall under by buildings situated in any site must not
exceed 80 percent from the total extent of said land. The area which didn‟t
fall under shall owned by the building and it must retain as part of the
building.
29. Vehicle Parking Facilities
(i) Every plan submitted along with the application for the purpose of obtaining
a development permit to carry out development activities, shall provide for a
minimum number of parking spaces within the site at the standards specified
in Schedule-05
(ii) The dimensions of car parking stalls shall be
(a) Minimum stall width - 2.4 meters
(b) Minimum stall length - 4.8 meters
(c) Minimum stall length for parallel parking 5.4 meters.
(iii) The minimum width of aisles where vehicle are parked must be in
compliance to the conditions contained in Form „B‟ of Schedule-05.
(iv) The width of access to car parking area shall not be less than 3 meters clear
of footways and other obstructions if entry and exit are separately provided
and 5.5 meters if entry and exit are provided together.
(v) The maximum gradient of ramps shall not be steeper than 1 in 8.
(vi) Every such ramp shall start only beyond a distance of 6.0 meters from the
street edge.
53
(vii) In issuing development Permit, the higher measurement either physical width
or proposed street line must be adopted as the width of the road may
obtained for development.
In a circumstance where the access road has marked by an approved street
line, if the landlord makes an opportunism donation of the land (situated
within the street line) by a deed to Ratnapura Urban Council or Road
Development Authority without additional expenditure, the Authority must
take into consideration to adopt total width of the street line as width of the
road.
(viii) Provisions are contained in Ratnapura Urban Development Plan to control
the vehicle transportation efficiently.
(a) Must have only one exit gate for allotments with surface width less
than 12.0 meters. But, in case the road surface access and exit gates
are more than two, then may consider granting permission for such
allotments.
(b) In circumstances of vehicle parking necessity within the developing
land, if the parking space for residential development is more than
100 and for non-residential development is more than 50, a suitable,
planned vehicle gathering road strip or vehicle retaining sub strip
must arrange as per the necessity by which may enable the vehicle
transportation without interruption in the developing land‟s access
road.
(c) In a circumstance where the vehicle parking space is more than 50
with relates to any development, the said development work must not
be allowed within 50 meters from a junction having two roads with
10000 vehicle transportation in each road or from a junction having a
road with 20000 normal vehicle transportation per day.
(d) Reflective glasses must not be used for ground floor, first floor or
second floor of any building which has faced to the road.
(ix) The Authority must request to police to conduct investigations by entering
into a building of which conduct is contrary to the motor vehicle
transportation controlling conditions and approved vehicle parking
conditions allowed for approved development.
(x) In a circumstance where a space approved for vehicle parking is used for
another task, the Authority must charge a service fee Rs. 5,000/- per month
for each lost space and shall continue till the lost space convert as the
approved vehicle parking space according to developing license.
30. Splaying of Street Corners
The Authority may require the corner of any buildings including boundary walls or
fences to be erected at the corner of two street‟s be rounded off or splayed to such
54
extent and height as may be necessary in the interest of the safety of the users of the
streets
31. Architectural Control
(i) According to Ratnapura urban development plan, the architecture, roof,
location of doors and windows, color, height matching, open areas,
advertising boards and name boards in any building of commercial zone and
Government and Semi Government Institutions Zone, the Authority may
order to the owner of any development work to change the said construction
as to match with development around, if the Authority seems required.
(ii) If shopping and commercial buildings join fully or half to any street, the
Authority can order to as a condition to construct an arcade with features and
width prescribed by the Authority from building‟s surface side.
(iii) The Authority may prescribe to cover (from view) any machinery or other
equipments that have been fixed on the building‟s top for their safety as the
Authority determines.
32. Conservation of Places those are Historically or Architecturally Important or
Important in Field of View.
(i) Newly additions, alterations or any task which may be a treat to the building
must not be done to conserve buildings described in Annexure-V, Volume-2
of Ratnapura urban development plan.
(ii) If the Authority determines that any place or area is important in aesthetic or
landscape side, the Authority can enact suitable provisions (depend on the
opportunity) to conserve said place or area.
33. Conservation of Landscape, Open Spaces and Trees
(i) The Authority can prohibit cutting down, chopping or purposely destroying
any herd of trees or flora or alteration of any important landscape feature
available in said area to protect the environmental vivacity.
(ii) The Authority can order the owner or the developer to maintain the
landscape of developing site, up to the Authority‟s approval.
(iii) If any land is located facing to Kalu Ganga, a herd of trees or bamboo trees
must be planted within the first 10.0 meters from river edge towards the land
for river edge‟s protection.
(iv) The Authority can order to implement the conditions contained in 33(3) with
regard to rivers, canal way conservations and other conservation limits stated
in Annexure-III, Volume-02 of Ratnapura urban development plan.
55
34. Controlling of Advertisements
(i) According to urban development regulations, if any advertisement or name
board is expected to display, the approval from Urban Development
Authority must be obtained.
(ii) Such advertisement must be placed only after obtaining the approval from
the Authority.
(iii) A rough plan of every name board or advertisement must be submitted to the
Urban development authority to obtain prior approval before to display them
in the town.
(iv) Such advertisements must well maintained after placing them the Urban
Development Authority reserves power to remove them within 02 weeks if
the Authority doesn‟t satisfy.
(v) Permission will not be granted for any advertisement to fix within the street
line perpendicularly to the road from which may interruptions occur to public
and vehicle transportation. (Figure -1)
(vi) No any permission will be granted to fix any advertisement around a junction
of four roads on any reason and only name boards indicating road direction
will be allowed. (Figure-2)
(vii) Permission will not be granted to place an advertisement opposite public
places (schools, temples, churches, hospitals, cemeteries, courts, open areas,
natural sceneries and mountain ranges) as to close them directly. But
permission will be granted to place advertisements 250 meters away from
such places.
(viii) Permission will not be granted to place advertisements in developing zones
as to destroy their characteristics.
(ix) When displaying a name board relevant to a building, no permission will be
granted to display it over the building‟ roof on whatever reason (Figure-03)
(x) When displaying a name board relevant to a commercial building in town
center, one horizontal level must be maintained between the aforesaid name
board and other name boards of the buildings situated in both sides of the
aforesaid building and the name board must be as follows.
The name board must be parallel to the external road.
If the building consists with 04 floors, the name board‟s area must be
1/40 of the front surface (building) exposing to outside. (Figure-04)
The name board must be displayed in a height of 2.5 meters from the
pavement.
Shape and letters of the name board must be maintained according to
the building‟s shape.
If the said name boards protruded beyond the wall, the protruded part
must be limited to 0.5 meters.
56
In a circumstance a flat maintained by various guardians for various
purposes, the name boards‟ dimensions come under Sub Clause X of
Regulation-34 and the name boards can be displayed in the surface of the
building relevant. (Figure-05 & 06)
(xi) Any advertisement or name board cannot be displayed in any road as to run
from one side to other side. (Figure-07“A” & “B”)
(xii) Advertisements must not be displayed towards the inner side of a bend in
any road. (Figure-08)
(xiii) Advertisements in all roads must be displayed in line with the opposite
direction to the driver and with an inclination of 600 to the road. (Figure-09)
(xiv) Fixing of advertisements and name boards in both sides of bridges in any
road will not be allowed. (Figure-10)
(xv) Advertisements and name boards must be prepared by materials from which
the environment doesn‟t get worm and their dimensions must be by way of
covering a minimum area.
(xvi) Using of super illuminating colors to color advertisements around the town
will be allowed.
(xvii) Displaying of any advertisement on following places is totally prohibited.
On a stem or a branch of a tree.
On walls and building walls
On bridges, electric and telephone posts.
On drainages and natural rocky plains.
In both sides of railway and on everything prohibited by the
Authority (Figure-11-i, ii & iii)
(xviii) Displaying of any advertisement / board by way of directly closing any
commercial or public building is totally prohibited. (Figure-12)
(xix) Displaying of advertisements on whatever reason in a downhill or a
mountain of a road will not be allowed. (Figure-13)
57
35. Buildings Located in Projection Services Roads
The Authority can determine the buildings‟ height located in Telecommunication,
Radio, Television or similar services roads after obtaining comments from
appropriate deputy institutions.
36. Distance to Electricity Cables
(i) The distance between overhead electricity cables and all buildings (from low
power cable) at least 2.5 meters vertically and 1.5 meters horizontally and
(from high power cables) 4.5 meters vertically and 2.5 meters horizontally.
(ii) If any building is located close to high power electricity cables, a certificate
of fitness obtained from Electricity Board or qualified person must be
submitted as to no damage or interruption occur to the activities carried out
in the building.
61
Part III
Building Conditions
37. Dimensions of Buildings
The internal clear dimensions of every room of a building except the rooms
described in Order-40 must be not less than the minimum measurements indicated in
Form “A” of Schdeule-06.
38. The clear dimensions of bathrooms and toilets must be not less than the
measurements indicated in Form “A” of Schedule-6.
39. (i) The store-rooms‟ to which not required lawful ventilation must not exceed
2.25 m2 and length must not exceed 1.5 meters.
(ii) The total area of all store-rooms consist with aforementioned dimensions
must not exceed 5% of the building‟s area.
40. The minimum height of rooms must be as stated below
a. For toilets, bathrooms and corridors must be not less than 2.1 meters.
b. For all other rooms in whatever building must be not less than 2.7 meters.
However, the said height spread up from roof‟s level due to beams, walls and
filial must be not less than 2.4 meters at any place: further,
c. The rooms‟ height of a centrally air-conditioned building must be not less
than 2.4 meters.
41. Regarding the rooms having a slanted roof must be not less than the measurements
(at center point of the slanted roof) contained in Order-40 and the minimum height
in any part of the room must be not less than 2.1 meters.
42. Stairs
(i) The minimum stairs‟ width, steps‟ length and width and height between two
steps must be in compliance to the dimensions indicated in Form “C” of
Schedule-6. Regarding circular geometrical stairs, the center steps‟ width
must be not less than the width indicated in the schedule above. The height
between any two steps of any stair from one floor to anther floor and a step‟s
height must often stay equal.
(ii) a Must not stay any barrier (in any stair) from uppermost stair bed up
to the exit gate situated in the ground floor.
b. If stair bed (in any stair), loggia or verandah, any side or any
compound is opened towards a space or outside area, every such stair
bed, loggia or verandah must safeguard by a 1.0 meter height hand
rail or hand fence or wall made according to suitable plan and method
62
by way of not fall down somebody from a side of the said stair bed,
loggia or verandah.
43. Supply of Light and Ventilation
(i) Natural light and ventilation to every room of every building by windows,
doors or any other approved ventilator must be provided.
(ii) Such windows and ventilators to provide natural light and ventilation to
every room of a building must left opened and facing :-
a. to a common street or any street having right of way for the building
owner ; or
b. to a compound or an opened area situated at the site belongs to the
building.
44. (i) Regarding rooms which are not relevant to warehouses and industries, any
part in the said room, by a distance of more than 10 meters from the direction
spreading horizontally to the said ventilators‟ level, left to provided light an
ventilation, must not be situated. Further, any part in such room, by a
distance of more than 3 meters from the direction spreading parallel to the to
the ventilators‟ level from its edge, must not be situated.
(ii) Regarding rooms which are relevant to warehouses and industries, any part
in the said room, by a distance of more than 12 meters from the direction
spreading horizontally to the said ventilators‟ level, left to provided light an
ventilation, must not be situated. Further, any part in such room, by a
distance of more than 5 meters from the direction spreading parallel to the to
the ventilators‟ level from its edge, must not be situated.
45. The way left to provide natural light and ventilation may open to a covered or half
covered loggia, verandah or a portico. In such times:-
a. The said loggia, verandah or portico must located facing to a street or
compound or an open air area;
b. Maximum depth of the room to which light or ventilation is provided by said
way must be not exceeding to the distance stated in Order-44 from the
external surface of said loggia, verandah or portico; further,
c. The front side of said loggia, verandah or portico must be left for open air
ventilation by a height not less than 2/3 from height between floor level and
ceiling level of said loggia, verandah or the portico.
46. (i) If any building‟s ventilators‟ total area is less than the specifications stated in
Form “D” of Schedule-6, natural light and ventilation by one or several ways
to every room must be provided.
(ii) Light and ventilation to corridors and can be supplied by constructing
ventilators in inter walls of rooms located adjoining to them. However, those
63
ventilators‟ area must be in compliance to the specifications indicated in
Form “D” of Schedule-06.
(iii) Regarding a room which is used as a garage where 5 or more vehicles
parked, cross ventilators at least 50% from the area of two or more sides of
said room must be provided to get ventilation.
47. In determination of light and ventilation, if half area of the common wall stands
between any two rooms is opened and unfettered, a said room can be considered as a
part of the adjoining room.
48. Regarding the buildings in depth of more than 12 meters of which sides‟ ventilators
are not located, permanent ventilation can be provided by constructing suitable
ventilators in front, back and all cross walls. (here maximum length must be 24
meters).
49. (i) Every window or other ventilator except toilets and bathrooms of a building
must left opened to a standard light level and whole space over the said level
except backyards and exposures spread to a distance not exceeding 1.0 meter
must left opened towards the sky without any barrier.
For the purpose of this Order the “Standard Light Level” means the level
drawn as to spread upwards, leaving 63 ½0 to the initial horizontal line from
land level (from the lowest level out of the building) which is not a ground
floor, allocated only for vehicle parking or to place an air-conditioner or any
other service machinery.
In a circumstance where any barrier (not an approved barrier) has been
located across any level drawn as above, the land level can be drawn from
the line gets cut after meeting the horizontal line of the said most remote
edge.
(ii) If a window or any other ventilator has been located in a building‟s side or
on the internal surface, the external open air space must be ;
a. the number of uk#l,ams; lines drawn across the open air space leaving
63 1/20, with vertical line, front side limit to the said building‟s
surface, which is not a ground floor but allocated for vehicle parking
or to place an air-conditioner or any other machinery, must be
available a unbreakable size of width from any part of the said
surface ;
b. Must be not less than 2.25 meter. ; further,
c. Must be entirely relevant to the building or consigned for public
usage.
(iii) Regarding toilets and bathrooms, if an unfettered 1 meter width open air area
within said site adjoining to the ventilator is available, the Authority can
relax the standards pertained to Standard Light Level.
64
50. If any room is located in the ground floor, at least 1/3 from the said room‟s external
walls‟ height must be located, above the external land level when supplying natural
light and ventilation. The full light and ventilation required must be supplied above
the external land level.
51. In a circumstance where a photographic dark room or refrigerating room and
according to the nature it is used, if ventilators cannot be located by way of directly
opened them to outside light and air and artificial light and mechanical ventilation
has supplied up to the Authority‟s satisfaction, the provisions contained in Sub
Clause-1 of Order-43 will not relevant to such room.
52. Supply of Mechanical Ventilation and Air-Conditioning
(i) In a circumstance where the Authority considers that a central air-
conditioning plant-yard is required to establish according to the building‟s
type and area, a somewhat change of provisions in these Orders regarding
natural light, ventilation and rooms‟ height which suits to the existing
circumstantial can be made meanwhile the development license is issued
under Section 8 of the Act as to maintain a planned system to supply
ventilation and light in compliance to the conditions prescribed by the
Authority. In such times a back-up electric generator consists with a voltage
determined by the Authority can be fixed and used in case a power
disconnection will occur.
(ii) The toilets‟ and bathrooms‟ windows or ventilators can make as to open to a
contracted air way, in case they can‟t open to an external or internal open air
area consists with a standard width. The surface area of such air way must
be not less than 1 m2 and minimum width of a surface side must be not less
than 1 meter regarding the buildings up to 15 meters height and the surface
area must be not less than 3 m2 and minimum width of a surface side must be
not less than 1.5 meters regarding the buildings above 15 meters height.
However, regarding two floors buildings, the ventilation for a such
buildings‟ toilets and bathrooms must be mechanically supplied by
exhausting fans (with a suitable voltage) fixed over the windows‟ open space
and top of the air way to sprinkle the interior air to outside.
(iii) If mechanical ventilation has supplied to an air-conditioned building and the
said air-conditioning or mechanical ventilation supplying method alias
artificial light supplying method is not further used, an assurance must be
given by the said building owner as he acts in compliance to the relevant
provisions contained in this Orders. Until the said owner acts in compliance
to the relevant Orders, it is considered that the said building is not suitable
for residential usage and must not use for residential purpose.
53. Foundations
(i) Every building must have built on a foundation by which can safely bear the
building‟s single weight and loaded weight by way of not occurring any
deposit or movement to avoid occur damages to whole building or its‟ any
65
part or adjoining building or workshop by way of securing the stability of
whole building or its‟ any part.
(ii) The land bears or supports to bear any building or its‟ any part must not
bring under any pressure (even due to any part of the building or by any
other way) which is not a stress accepted by the Authority in view of
ensuring the safety of said building‟s residents.
(iii) Regarding any proposed building, if stress is given to said building‟s any
part by the adjoining land or causes to apply an unsuitable weight, the said
building or part of the building must build as able to bear or transmit the said
stress or weight without damage by not leaving room to exceed the
authorized stress.
(iv) In such circumstances where the land inclination of any land is from 50 to
300, the required instructions to construct a foundation must be obtained
from the Authority before to prepare the land.
54. Except with regard to a boundary wall constructed with site owners‟ mutual consent
where a boundary wall is situated, any building‟s foundations must not propagate
beyond the said site‟s boundary lines where the said buildings are constructed.
55. (i) Before to commence the foundation works alias any related soil works in the
related work site i.e. piling, soil works such as soil compacting, earth
excavating from which may occur whatever adverse effect to any portion of
adjoining property‟s stability or may occur movements or stress in the
adjoining property, the qualified person must very carefully watch the plans
and planning works when they are prepared prescribed under this Order.
(ii) Always preventing from damages to an adjoining building by their own cost
is the responsibility of the qualified person and the owner.
(iii) The whole works including foundation excavating and temporary detention
works must be demerged from an adjoining road or property by a suitable
fence or caging as prescribed by the Authority.
56. Electric Escalator
The electric escalators that must be fixed in a building for passengers, to carry stuff
and the number of electric escalators, their construction plan, manufacturing, testing,
checking and operating must be in compliance to the conditions contained in Form-
“E” of Schedule-06 of these Orders.
57. Water Supply
(i) A safe water supply system connected to the existing common water supply
system must be available in every building.
(ii) If the aforesaid water supply system cannot connect to a common water
supply system, a water supply system connected to a private water supply
system must be arranged.
66
(iii) Taking into consideration of the building‟s location and other landmarks of
area and reasons available to Authority to believe that a continuous water
supply may not occur, water tanks and pumps consist with a capacity
prescribed by the Authority must be supplied for every building in each
situation.
(iv) Any well supplied drinking water must not be located closely by a distance
of 15.0 meters from an impure water porous pit adjoined to a cesspit or septic
tank.
58. Sewage and Sanitation
(i) At least one water sealed toilet for every residential unit and water sealed
toilets, urine containers, wash basins and other sanitary facilities for every
other building must be available. The number of water sealed toilets, urine
containers, wash basins and other facilities provided to a building among
must be in compliance to the conditions contained in Schedule-09.
(ii) All overflows used to discard dung and impure water must be connected to
an existing sewage system and the Authority can prescribe in any special
occasion that they must connect to a common sewage system after
chemically cleaned according to an identified standard.
(iii) a. In a circumstance where a common sewage system is not available or
if the Authority considers that it is difficult to connect to such sewage
system, then must make arrangements to pass them to a septic tank.
b. A suitable arrangement must make to pass the impure water gathered
in septic to another porous pit.
59. Rain Water Drainages
Sufficient drainage facilities for every building must be provided in order to avoid
damages or getting wet the foundation or adjoining buildings‟ walls by rain water,
by way of passing the rain water from building‟s roof to a street‟s drains or to an
approved overflow pit.
59 (1) Every owner or developer shall at the time of submission of the
building plans for approval of the development activity in terms of
these regulations, submit along with such plan, a plan containing such
sketches as may be necessary, prepared taking into consideration the
specifications and other requirements set out in Schedule VIII (Part I,
Part II and Part III) to these regulations, of the respective drainage
facilities intended to be put in place to drain off and convey rain
water from the roof of the proposed building to a drain in the street or
other appropriate outlet approved by the respective Authority:
Provided that, in the case of existing buildings, the authority shall
give adequate notice to the owners thereof, informing them that they
will be required to comply with the provisions of this regulation,
within such period as may be determined by the Authority, but such
67
date shall not be later than three (03) years from the date of
enforcement of those regulations.
(2) Every Plan prepared under these regulations shall be prepared by a
qualified person as determined by the Authority.
(3) The provisions of these regulations shall be applicable in respect of
such areas as have been declared as Urban Development Areas by
Order published in the Gazette in terms of Section 2 of the Law.
(4) In applying these provisions to open space reservations stipulated in
relation to the sub division of land, a minimum of ninety (90%)
percent of such reservation shall have ground cover vegetation.
59 A. The provisions of regulation 61 shall apply to all premises within
any local authority area, declared as Urban Development area under
the Law.
Provided that the above provisions shall not apply in respect of
premises falling within any local authority area, where the size of the
premises is less than 6 perches (150 m2).
59 B. (1) Every plan submitted for the purpose of obtaining a
development permit shall consist -
(a) Where no building work is involved in the
development activity or the development activity is
restricted to land development –
(i) Of details of the location and the dimension
of the existing drainage system;
(ii) Of the proposed rainwater harvesting system
inclusive of all dimensions and flow directions;
(b) Where building work is involved in the development
activity.
(i) Of a sketch of the plan of the surrounding
area including positioning of existing water
drains.
(ii) Of the floor plan of each story (where the
building consists of more than one floor) and
of any areas which will consists of a flat roof
(all pipe lines of the drainage, sizes and
location of storage and infiltration and outlet
drains along which the rain water will be
discharged, with arrows indicating the
direction of the flow of the water should be
shown);
68
(iii) Of the cross and longitudinal sections of the
building, including storage tanks, down pipes
and other related appurtenances.
(2) The guidelines set out in sub-paragraphs (a) and (b) of
paragraph (1) of this regulation shall be applicable to the Uses
of Buildings specified in Schedule VII (Part I) to these
regulations and the Maximum Equivalent Rainwater Holding
provisions Requirement for each of such categories shall be as
specified in the said Schedule (Part II);
Provided that where any applicable building uses or relevant
rainfall band is not clearly identifiable, Authority / the Local
Authority shall on a consideration of all conditions, make the
required identification:
Provided further that the Proposed Distribution of Rain Water
Harvesting Holding Provision shall be calculated in
accordance with the Storage and Groundwater Infiltration of
the premises as specified in Part III of Schedule VII.
59 C. (1) Where common rainwater holding facilities are proposed
by one or more owners of adjacent properties, such joint
facility shall be located at such place as may be determined by
the Authority / respective local authority; Provided that the
Authority shall satisfy itself that all owners concerned have
consented to the joint facility and have given their written
consent thereto.
(2) In assessing the Equivalent Rainwater Holding Provision of
any premises:-
(a) The following matters shall be considered –
(i) Available storage space for the requirements,
provided measure are adopted to meet fire
requirements at all times;
(ii) 100 m2 of unpaved ground sufficient for 0.5
m3;
(iii) Location of infiltration trenches specially for
rainwater; and
(iv) Any facilities available on adjacent premises
where, the written consent of the owner thereof
has been obtained for the use of such facilities.
69
(b) The following matters shall not be considered –
(i) Storage spaces for public mains supply;
(ii) Availability of septic tank effluent soakage pit
or trench.
59 D. The following design and construction consideration shall be
applicable in relation to ground water harvesting in terms of these
regulations :-
(a) The rainwater system shall be designed by persons possessing
the requisite qualifications as specified from time to time, by
the Authority and shall -
(i) Be constructed in competent manner;
(ii) Be capable of discharging the first flush of rain;
(iii) Be stored on appropriate structures and sized and be
infiltrated into the ground, by means of either a waste
water soakage pit, a dug or bore well, pond or other
similar measure, ensuring that optimal use of the water
is made for home garden and landscaping purposes;
(b) The storage structure shall be covered and protected against
accidents and shall -
(i) Be built in a structurally sound manner;
(ii) Contain provision for the elimination of dust, vermin
and other contaminants;
(iii) Be of such design which shall not conflict with any
other building regulations or aesthetic considerations
imposed by the local authority;
(iv) Be located at appropriate locations either above, below
or on, ground level, so as to facilitate the potential for
the maximum use of the water storage therein;
(c) In case the water is not used for home gardening and other
purposes, the infiltration structure shall be of such specified
dimensions in order to be able to contain the quantity of water
directed to it ensuring proper infiltration.
(d) In the case of common storage structures, be built with
suitable backflow prevention devices, so as to prevent
rainwater from entering the public mains systems;
(e) Shall not contain direct cross flow connections between the
rainwater and the public mains systems;
(f) Shall contain such filtration devices as are specified by the
local authority; and
70
(g) All pipes and appurtenances used for the provision of
harvesting of rainwater shall be clearly differentiated by color
and makings;
60. Solid Waste Disposal
The waste generated in any place can discard after collecting by way of protecting
the residents‟ of that place as required and considered by the Authority.
61. Electricity and Pipe Works
All electricity and pipe works of any place or a building shall do by a registered
electrician or a plumber as per the relevancy by way of protecting the maximum
safety and hygienic of said building or place and said works must be done in
compliance to the standards and specifications determined by the Authority.
62. Protection from Fire
Every building must be in compliance to the fire protection requirements as relevant
/ appropriate to said area or building as determined by the Authority in order to
provide a better protection from fire to the residents in said area or building.
63. Regarding all supper high buildings and buildings more than 400 m2 where public
gathered, factories and stores, the equipment fixed there must be in compliance to
the additional security requirements recommended by the Chief Officer of fire
brigade.
64. A water pond to store water to use in a fire caught occasion, for all buildings located
in areas where the water supply has given by pipes and the buildings consist with
two floors or above and in extent of 300 m2, must have constructed within the
building premises. The measurements of such water pond can determine by the
planning authority according to the buildings‟ extent and the purpose of those
buildings are used.
65. Certificate of Conformity
Every application for a Certificate of Conformity under Section 8K of the Law shall
be substantially in the Form “D” set out in Schedule (I) and shall be accompanied by
the following :-
(a) In the case of land development or sub-division of land :-
(i) A certificate from a qualified person stating that the sub-
division has been carried out as specified in the approved
plans and permit;
(ii) A certificate from a qualified person where engineering works
are involved in development activities such as the
construction of roads, culverts and drains, stating that the
development works carried out in conformity with the
specifications of the permit.
71
(b) In the case of construction of buildings falling within Category A of
regulations 8 :-
(i) A certificate from a qualified person to the effect that the
development has been carried out under his supervision and in
accordance with the approved plan and permit;
(ii) A certificate from a qualified person to the effect that the
foundations and super structure and other works have been
carried out under his supervision and according to the
approved plans and permit and according to designs submitted
under regulation 9, and that the buildings are structurally safe;
(iii) A certificate from a qualified person to the effect that design,
supervision and installations of Electrical Work, Sanitary,
Plumbing and Drainage Water, Rain Water Harvesting
specification, Air Conditioning Fire Safety Work, have been
carried out in accordance with the approved plans, and
specifications and satisfy all safety regulations;
(c) In the case of construction of buildings falling within Category B of
regulation 8, a certificate from a qualified person to the effect that the
works have been carried out under his supervision in accordance with
the approved plans and permit and that the building is structurally
safe;
(d) In the case of the construction of buildings falling within Sub
Categories C I and C II of Category C of regulation 8, a Certificate
from a qualified person to the effect that the work has been carried
out and under his supervision in accordance with the approved plan
and permit; and
(e) In the case of the construction of buildings falling within Sub
Categories C III of Category C of regulation 8, a Certificate from the
builder, or the owner where the owner is also the builder by such
owner to the effect that the works have been carried out in
accordance with the approved plans and permit under his supervision,
and that all reasonable precautions have been taken to ensure the
structural safety of the building;
66. The Authority or any authorized representative of the Authority can enter into
whatever building to check within a justifiable time to determine whether all
provision in these Orders have been followed within any period of the development
work before to issue a certificate of conformity to reside in any building.
67. Unprotected Buildings
If any building has been certified by the Director-Department of Buildings that it is
unprotected, the Authority can order the said building (which is dangerous to
residents and public) owner to repair or demolish or to act another way in order to
prevent from said risk.
72
68. Special Requirements for Flood Prone Areas
All buildings constructed in flood victim zone must be in compliance to the
following conditions.
(i) All building constructed in this zone must consist with two floors (minimum)
and only pillars are allowed to construct in the ground floor. (see figure- 14,
15)
(ii) The building plans and foundations for this zone must be submitted after
certified by a Chartered Engineer and a Chartered Architect as suitable for
flood victim zone.
69. Mining Industry
In compliance to Ratnapura urban development plan, if mining and lodes washing
are done, special attention will be drawn in respect of the changes may occur in the
land/allotment and effects to the constructions in cause of said activities.
(1) Effects due to the mine/hollow must not occur to the existing properties,
buildings, roads including other constructions and physical environment.
(2) According to the accesses stated in 01 above, any effect or damage must not
occur in respect of following sectors.
i. Ancient or historically important places.
ii. Conserved zones.
iii. Flood victim zones.
i. Socially important places.
ii. Mining carried out around the landslip and landslip tendency zones.
(3) The following conditions of Gems and Jewelry Authority must follow to
minimize the environmental damages occur due to mining industry.
i. Subsidences occur due to tunnel excavating.
ii. Situations of rivers‟, canals‟ and rivulets‟ edges due to mining industry.
iii. Landing of lodes in rivers, canals and rivulets using man power and
machineries.
iv. Pollution of water resources and water ways due to lodes clearing.
v. The ways of mining pits are filled with earth after excavation.
iii. Soil wash away due to mining industry and thereby soil deposit and natural
water ways get filled.
iv. Situations of damages occur to highways and roads.
Before to carry on all mining, lodes washing etc… within the Domain of Ratnapura
Urban Council, the written approval from this Authority must be taken and the duly
filled form indicated to Form-“C” by Annexure-II of these regulations must be
submitted to this Authority.
The written approval for mining obtained from the Authority of Gems and Jewelry
must be submitted together with the above application.
73
70. Providing Facilities for Disabled Personnel
Roads, corridors, steps, escalator equipment, toilets of common buildings such as a
hospitals, theatre, meeting hall, large trade complex must be by way of easy entrance
and exit for disabled personnel and to use other facilities and shall follow the
provisions contained in Shedule-9 for implementation of Section 23(ii) of Act No.
28 of 1996 to defense disabled personnel‟s rights.
74
Part IV
Definitions
71. The Definitions in these Orders are as follows -
“Apartment” means a unit as defined in the apartment ownership law no. 11 of 1973.
“Access” includes any street used as means of access to building or other premises
whether the public have a right of way there over or not.
“Authority” means the Urban Development Authority constituted under Urban
Development Authority Law No 41 of 1978.
“Basement” means that part of the floor below the ground floor which is wholly
below ground level or to an extent of 2/3rd of its height below the adjoining ground
level.
“Building high-rise” means any building with more than 4 floors including the
ground floor or whose height at any part of its ground level exceeds 15 meters
excluding a lift or motor room not exceeding 50 2 m in extent or stair case of not
exceeding a height of 3 meters and not exceeding 25 2 m in extent or a water tank
not exceeding a height of 1.5 meters.
“Building residential" means a building exclusively consisting of one dwelling unit
or number of dwelling units.
“Building line” means a line up to which a building will be permitted to extend.
“Building works” means includes erection or re-erection of a building or making
additions or alterations to an existing building.
“Chairman” means the Chairman of the Urban Development Authority.
“Dwelling house or dwelling unit” means a building or a part of a building
consisting of a room or group of rooms forming a self-containing living unit with
independent sleeping and cooking and sanitary facilities.
“Development activity” has the same meaning as in the Law.
“Existing lot” means a lot which in existence before coming into operation of the
Law.
“Factory” means includes a building or a part of a building used for the manufacture
or production or repair of any article.
“Flat” means a unit as defined in the Apartment Ownership Law 11 of 1973.
“Floor area” means the horizontal area of floor of a building measured from the
exterior faces of exterior walls or in the case of a common walls separating two
buildings from the centre line of such common walls and shall include all roof,
76
projections and balconies exceeding one meter in width and all areas having a roof
and capable of being enclosed.
“Gross Floor Area” means the total of the floor area of every floor in the building.
“Floor Area Ratio” means gross floor area of all buildings on a lot divided by the
area of such lot.
“Floor space” means a horizontal area of a room or space in a building measured
from the interior face of the enclosing walls
“Housing Complex” means a group of dwelling units on a site which is permanently
in common enjoyments and may include a blocks of flats.
“Industrial building” includes factories, workshops and warehouses.
“Law” means the Urban Development Authority Law No 41 of 1978.
“Local Authority” has the same meaning as in Law.
“Lot” in relation to land means the entirety of any land which has been demarcated
by boundary marks or enclosed within boundary walls or fences where such land
belongs to one single person or to a set of co-owners and approved as a lot by the
local authority or the Authority.
“Owner” includes a person for the time being receiving the rent of the premises in
connection with which the work is used whether in his own account or as a agent or
a trustee for any other person or who would receive the same if such premises
were let to a tenant.
“Place of public assembly” means a place or building used regularly or occasionally
for public congregation, such as theatre, cinema hall, pubic hall, concert room
lecture room or exhibition room or for similar purpose and includes a public
building.
“Planning committee” means a committee appointed under “Section 8 B” of the
Law.
“Public building” includes any building used for the purpose of public worship,
instruction, recreations, or meeting and a medical institution or a nursing home or
government office.
“Public street” means any street over which the public have a right f way and has
become vested in any Authority under any Law or by operation of any Law and
includes the drain or footway attached thereto.
“Street” includes any road, footway, or passage used or intended to be used as
means of access to two or more dwelling units or sites whether or not the public has
right of way over such street and includes all channels , drains, ditches, side walls
and reservation at side thereof.
77
“Street line” means a line or lines defined on one or both sides of an existing street
to show its future width or to show the width of a future street as determined by the
Authority.
“Warehouse” includes a building or a part of building mainly used for storing
merchandise or articles for trade.
“Qualified person” the Qualified Persons who certify the Plan should be responsible
to the accuracy of the Plan, ensuring its conformity with the UDA Planning and
Building Regulations. Further, the Organization which register the Qualified Persons
shall submit the annual members registries to the Authority and the Draught-Persons
(Building) at NVQ, Level V shall register their names with the Authority annually.
(See Schedule III)
78
Part V – Schedule
Schedule – I
(According to Order-2)
Application to Obtain a Development Permit for Subdivision of a Land
For office use only
Number :
Processing Fee: Rs.
Receipt No. :
Date :
Chairman,
Urban Development Authority,
Through : Mayor
Ratnapura Municipal Council.
Sir,
I / We hereby apply for a permit for Sub Division of my / our land bearing Assessment No
………. of the …………………………..Street/Road/Lane/Avenue in the ………
………………………..Ward (No ) of Ratnapura Town.
I / We forward herewith following particulars in duplicate duly signed by me / us and the
Qualified Person:
1. A map of the area showing the site /land in relation to the adjoining properties
and street to a scale not less than 1:4000 (the site in question along with any other
adjoining site owned by the applicant should also be clearly shown).
2. A Survey Plan of the site / land to a scale not less than 1:1000.
i. The location of the site including figured dimension of building if any
ii. The scale of the plan the north point and assessment numbers of adjoining
lots or buildings
iii. The mean of access to the site
iv. All existing drains and water courses
v. Contours or spot levels of the site and levels on the street in front of the
building
vi. Service lines including electric power lines
vii. Trees and vegetation
3. A detailed blocking out plan to a scale of not less than 1:1000 showing the proposed
sub division of lots together with their dimensions and extent, direction and with of
all proposed streets, open spaces and space for other amenities to be reserved and the
use to which every site will be put to.
79
4. The proposed formation levels of streets in relation to existing levels with cross
section and longitudinal sections to scale.
5. The particulars detailed in the Annexure.
I /We certify that the information given above is true and correct.
I / We undertake not to commence any development activity till the permit is
granted.
…………………………..
Signature of the applicant
Date …………………….
…………………………………..
Signature of the Qualified Person:
Date ………………….
Name and address: ……………………………..
……………………………..
Telephone No : ………………………
Email No : ……………………………….
Fax No : …………………………….
80
Annexure to Form “A”
(Please type or write in block capitals)
1. Particulars of the applicant
Name :-
Address :-
Telephone No. :-
2. (a) Particulars about existing development
Location :-
Assessment No. :-
Local Authority :-
Ward :-
Street :-
Lot / Survey Plan No. :-
(b) Present use of the land
Land :-
Extent (m2) :-
Usage :-
Buildings if any :-
3. (a) Development of the site
Whether the site is proposed to be filed up and raised and if so give details of
levels in relation to access roads and drainage proposals. Please also indicate
(where applicable) whether consent of Land reclamation and Development
Corporation has been obtained
(b) Details about facilities :-
(c) Proposed development of the site :-
Residential
Commercial
Industries
Institutions
Open spaces – parks & playground
Streets and access roads
Other uses
(d) Infrastructure
i. Availability
Water
Sewerage
Storm water drainage
Electricity
81
ii. Proposed arrangements where the above faculties are not available or
no adequate
Water
Waste disposal
Storm water drainage
Electricity
4. Landscape: location of trees to be indicated on the site plan.
5. If the Sub Division involves the division of building, state how each art of building
will be brought into conformity with the Planning and Building Regulations.
6. Approximate date of commencement, phasing and dates completion of construction.
I / we hereby certify that the above particulars are true & correct.
……………………………… …………………………..
Signature of Qualified Person Signature of the Applicant
Date: ……… Date: ………………..
Name & Address: …………………………….
…………………………….
Telephone No.: …………………………
Email No. : …………………………….
Fax No. : …………………………..
82
Schedule – I
(According to Order-2)
Form – “B”
Application to Obtain a Development Permit (Except Lands Subdivisions) for
Building Constructions, Changing of Lands and Buildings Usage and other
Development Work.
For office use only
Number :
Processing Fee : Rs.
Receipt No. :
Date :
To : The Chairman of Urban Development Authority
Through : Mayor
Ratnapura Municipal Council
Dear Sir,
I/We hereby apply for a permit to carry out the following development. I/We intend to use
the land or building in ………………….. for ……………………………… The site sub
division has been approved by …………….. in ………….
I/We forward herewith the following particulars in triplicate
1. A map of the area showing the site in relation to the adjoining properties and streets
(The site in question along with any other adjoining site owned by the applicant
should also be clearly shown).
2. The approved blocking out plan to a scale of not less than 1:4000 showing the
dimensions of the site and all existing topographical features, buildings, structures
and street width of abutting streets.
3. A detailed plan of the site to a scale less than 1:1000 indicating the position of the
proposed Buildings in relation to the site, (existing buildings to be retained) street
lines, the set backs from the streets and the boundaries of the site, access ways and
location of parking areas.
4. In case where only building work is involved.
(a) A sketch plan of the surrounding area sufficient to locate the building site.
(b) The approved blocking out plan to a scale of not less than 1:4000.
(c) A floor plan of each storey drawn to a scale of 1:100 except where the
building is so extensive as to render a smaller scale necessary when the scale
of 1:200 may be used showing:
83
(i) Different parts of the building and the use for which every room and
part of the building is intended to be put to.
(ii) The position and dimension of all doors, windows and other
openings.
(iii) The position of all sanitary appliances and their connection to drains.
(iv) Fire escape
(v) Clearance from aerial electricity supply lines
(vi) The type of materials and specifications to be used for the walls,
super structure and floor slabs and roof structure of the buildings.
(d) Cross and longitudinal sectional drawings of the building along appropriate
lines, showing:
(i) The thickness of all walls, floors, roofs, foundations, beams and other
related parts of the buildings.
(ii) Position and dimensions of doors, windows or other openings, the
height of every storey, the ceiling height and levels of the buildings
in relation to existing ground or street level and the clear distance
between the site boundaries and the external walls of the buildings.
(e) Front and side elevations of the building showing elevations of every
existing building with the site showing its height, floor level and other
external visible features.
5. Details given in Annexure - “B1”.
6. Details given in Annexure – “B2” (when the development work is for site and
building technics usage).
7. Details given in Annexure – “B3” (when the development work is relevant to a
hotel).
I/We certify that the particulars stated above are true and correct.
I/we agree that any development work will not be commenced until the development permit
is issued.
……………………………
Signature of the Applicant
…………………………………
Signature of the qualified person
Address :-
Date :-
Telephone No. :- e-mail :- Fax :-
84
Schedule – I for Form - “B”
(Please mention the details clearly by handwriting or typewriting)
1. Particulars of Owner:
Name:
Address:
Telephone No.:
2. (a) Particulars of Existing Development :
Location of site
Local Authority:
Ward:
Street:
Assessment No.:
Lot No./Survey Plan No.:
(b) Present use of the land and building:
(i) Land
Extent (in sq.m.):
Use (Give in detail the present use):
(ii) Building (Give details of every building on the site).
No. of floors:
Height (meters):
Gross Floor Area (sq.m.):
3. Particulars of Proposed Development:
(a) Nature of Proposals
(b) Site Development
State whether the site is proposed to be filled up and raised and if so, give details of
levels in relation to roads and the drainage proposals.
Please also indicate (where applicable) whether consent of the Sri Lanka
Reclamation and Development Corporation has been obtained.
(c) Details of Development
Maximum Height (Meters)
Gross floor area of all buildings (sq.m.)
Gross Floor Area of all Buildings
Floor Area Ratio ----------------------------------------
(F.A.R.) Site Area
Floor area at ground level
Lot Coverage --------------------------------------- x 100
Site Area
(d) No. of Floors (including Basement and use of each floor):
Floor Use Extent (sq.m.)
85
(e) Details of Floor Area (sq.m.):
Residential:
Retail Commerce:
Wholesale Commerce:
Office:
Restaurant:
Factory or Workshop:
Warehouse:
Others (specify):
TOTAL:
(f) Floor area of each Dwelling Unit
(g) Parking of Vehicles:
Cars:
Other (Specify):
(h) Infrastructure Requirements:
Water (Liters):
Electricity (Kilo watts):
4. Estimated No. of Employees in the Building
5. Landscaping:
Trees and vegetation to be retained.
Landscape proposals:
Describe proposals with an outline design
6. Approximate date of commencement and completion and phasing:
I/We hereby certify that the above particulars are true and correct.
……………………………… ……………………………
Signature of Qualified Person Signature of Owner
Address:
Telephone No.:
Date:
86
Annexure – 2 for Form – “B”
(Please mention the details clearly by handwriting or typewriting)
To be completed and furnished where the site and building are to be used for Factory,
Workshop or Warehouse.
1. Nature of Factory, Workshop or Warehouse (Give details of goods to be
manufactured, repaired or stored and in the case of manufacture indicate raw
materials used and a brief description of the manufacturing process)
2. Details of permission of the concerned Ministry of Department for setting up the
factory or workshop or ware-house.
3. Details of machinery employed and motive power.
No. Horse Power Motive Power
4 Provision made for infrastructure facilities
Water :-
Liters :-
Source :-
Sewage :-
Disposal :-
Liters :-
Electricity :-
Kilo Watt :-
Source :-
Storm Water drainage :-
Fire Protection :-
5. Quality and Quantity of solid, liquid or gaseous effluents, there mode of treatment
and disposal.
6. Noise, dust and pollution characteristics and measures proposed for their control.
7. Employment
Proposed:
Future expansion, if any,
87
I/We certify that the information given above are true and correct.
………………………………
…………………………….
Signature of Qualified Person Signature of Owner
Address:
Telephone No.:
Date:
88
Schedule – 1
Form – “C”
Application to Obtain a Preliminary Planning Clearance for Proposed Development
For office use only
Number :
Processing Fee : Rs.
Receipt No. :
Date :
To : The Chairman of Urban Development Authority
Through : Mayor
Ratnapura Municipal Council
Dear Sir,
I/We hereby request the Preliminary Planning clearance relevant to the partition of building
/ land situated at ………………………… bearing Assessment No.
………………………… of …………………………………. street of
……………………………. Division of ………………………….. town.
I/We herewith submit the application in triplicate along with following details after signed
by the qualified person.
1. Maps drawn in a scale not less than 1:6000 relevant to adjoining properties and
streets indicating the site/land (an adjoining site belongs to the applicant with
relevant site must be clearly indicated.)
2. I/We am/are fully aware that no entitlement will extend to me/us to carry on a
development work in any land in cause of the primary plan settlement described in
the Annexure.
The consent letter obtain from the landlord has annexed hereto.
I/We certify that the particulars stated above are true and correct.
……………………………
Signature of the Applicant
Signature of the qualified person
Date :-
Telephone No. :- e-mail :- Fax :-
89
Annexure to Form “C”
(Please mention the details clearly by handwriting or typewriting)
1. Particulars of applicant:
Name:
Address:
Telephone:
2. (a) Particulars of existing development
Location:
Assessment No.:
Local Authority:
Ward :
Street :
Assessment No. :
Plot / Survey Plan No. :
(b) Present Use
(i) Land
Extent (Square Meters):
Use (Give in detail the present use):
(ii) Building (Give details of every building on the site):
No. of floors :
Maximum height (meters):
Gross floor area (sq.m.):
Floor area of each use (sq.m.):
3. Particulars of proposed development:
(a) Site development – (State whether the site is proposed to be filled up and
raised and if so give details of levels in relation to roads and drainage
proposals. Please also indicate (where applicable) whether consent of Sri
Lanka Land Reclamation and Development Corporation has been obtained).
(b) Nature of proposals (Give a brief description with line plans and elevations).
4. Site Particulars
Extent of site (sq.m.)
5. Availability of Infrastructure:
Street and Access ways:
Water Supply:
Sewage :
Electricity :
90
6. (a) Gross Floor area of Proposed Development (sq.m.) :
(b) No. of floors and maximum height of building :
(c) Floor Area Ratio Gross floor area of all buildings
F.A.R. --------------------------------------
Site Area
(d) Plot Coverage Floor area at ground level x 100
--------------------------------------
Site Area
(e) Basement
(i) Extent:
(ii) Ground Coverage:
(f) Details of floor space (sq.m.)
Residential:
Retail Commerce:
Wholesale Commerce:
Office:
Restaurant:
Factory or Workshop:
Warehouse:
Others (specify):
Total:
(g) Parking spaces provided:
Cars:
Others (specify):
7. Details of site sub division sq.m. % total area
(a) Land use:
Residential:
Commercial:
Industrial:
Institutional:
Open spaces, parks and play fields:
Roads
Others
(b) No., type and size of plots:
(c) No., type of buildings, if any proposed:
(d) Amenities if any, to be provided:
I/We certify that the above particulars are true and correct.
……………………………….
Signature of Owner/Applicant
Address:
Telephone:
Date:
91
Annexure – II According to Form “C”
(Please mention the details clearly by handwriting or typewriting)
Application for Mining
01. Details about the applicant :-
Name :-
Address :-
Telephone No. :- e-mail :- Fax :-
02. (a) Information about the existing development works :
Location of the development place :-
…………………………………………………………………………………
…………………………………………………………………………………
Assessment No. :- …………………………………………………………….
Provincial Institution :-
………………………………………………………………...
Street :- ……………………………………………………………….
Block No. / Survey Plan No. :-
……………………………………………………….
(b) Present utilization :
Land 1. Extent (square meters)
2. Utilization: (indicate with details about present utilization)
3. Distance from relevant allotment to roads and all
constructions (a survey plan drawn in a scale not less than
1:1000 including above constructions (if available) or
adjoining lands must be submitted)
4. Mention whether rivers, canals, rivulets.
03. Is the development place for mining located in a licensed zone ?.................................
…………………………………………………………………………………………
04. Details about the land location:
1. Is it a flood victim place ?..................................................................................
2. If floods occur, mention the annual flood levels indicate from which height
from the land
…………………………………………………………
3. Do landslips occur ? (provide a plan to indicate the positional height (if
available))
………………………………………………………………………………
Depth intended for mining –
……………………………………………
4. If tunnels will excavate to the expected length and width from the mine‟s
surface level, distance from the bottom :
…………………………………………………………………………………
…………………………………………………………………………………
05. Mention about the machineries used to excavate the mine (if any).
…………………………………………………………………………………………
…………………………………………………………………………………………
92
06. i. Is it possible to provide space within the land to deposit the soil removed
from the mine ?.
…………………………………………………………………………………
ii. If impossible, method of said soil is deposited:
…………………………………………………………………………………
…………………………………………….
iii. Method of the lode is washed :- ………………………………………………
…………………………………………………………………………………
iv. The water source to wash the lode :-
………………………………….
v. Does relevant water add to natural water or not ?. :-
…………………………………………………………………………………
……………………………
07. Method of bring up to a certain position after completing the mining:-
Is the soil brought from outside ?. ……………………………………………………
Is it by another way ?. ………………………………………………………………...
93
Schedule – I
(In Compliance to Order – 66)
Form “D”
Application to Obtain the Certificate of Conformity
For office use only
Number :
The Processing Fee Paid: Rs. ………….
Receipt No. :
Date :
To : The Chairman of Urban Development Authority
Through : Mayor
Ratnapura Municipal Council
Dear Sir,
I/We hereby request to issue a certificate of conformity for the development work carried
out in terms of the permit (mention the location) bearing number …………………… dated
…………………….20 issued to/me us by ………………………………….
Works completed fully in compliance to the permit./completed with under mentioned
changes. (strike off the unnecessary part.)
Details about changes
…………………………………………………………………………………………………
…………………………………………………………………………………………………
…………………………………………………………………………………………………
The following certificates under the Orders have annexed hereto.
I/We certify that the information provided above are true and correct.
I/We hereby agree that no any development works will be carried out and to refrain from
using the land/building until the certificate of conformity is awarded.
………………………..
Signature of the Owner
Date :
Signature of the qualified person
Address :-
Date :-
Telephone No. :- e-mail :- Fax :-
94
Schedule II
PROCESSING FEES, FEES FOR COVERING APPROVAL AND SERVICE
CHARGES FOR OBTAINING DEVELOPMENT PERMITS
Nature of Development activity
to be engaged in
Form to
be used
Fees
1. Issue of Development Permits
(I) Land Subdivision Approval
(II) Issuing of Development
Permits for erection of
Buildings/ addition to
existing buildings/ re-erection
(III) Erection of Boundary Walls/
Retaining Walls
On the building line
Within building line
A
B
Processing fees
(i) Plot Size Fees for each plot
(Excluding road drains
and common lots)
Between 150-300 sq.m. Rs. 500.00
Between 301-600 sq.m. Rs. 400.00
Between 601-900 sq.m. Rs. 300.00
Above 900 sq.m. Rs. 200.00
(ii) Floor area Residential Uses Commercial
(sq.m.) Rs. Cts. Other Uses
Rs. Cts.
Less than 45 500.00 1,000.00
45-90 1,500.00 2,000.00
91-180 2,500.00 3,000.00
181-270 3,500.00 4,000.00
271-450 4,500.00 6,000.00
451-675 5,500.00 8,000.00
676-900 6,500.00 10,000.00
901-1225 7,500.00 12,000.00
Above 1225 7,500.00 12,000.00
Rs. 1,000/- for Rs. 1,250/-
every 90 sq.m. for every 90
in excess of sq.m. in
1226 sq.m. excess of
1226 sq.m.
(iii) Residential Commercial
(Per liner meter) and Other
(Per liner meter)
Rs. 300.00 Rs. 400.00
Rs. 500.00 Rs. 600.00
95
(iv) Reclamation of Low Lying
lands/ Paddy lands
(v) Erection of
Telecommunication Antenna
Towers
(vi) Issuing of Development
Permits for Special Projects
2. Change of use Residential
3. Preliminary Planning
Clearance
(i) Sub division of lands
(ii) Erection of buildings/addition
to existing building re-
erection
(iii) Erection of Boundary walls/
Retaining walls
B
C
C
C
(iv) Rs. 1,500/- for land less than 150 sq.m. and
Rs. 1,000/- for each 150 sq.m. in excess
(v) Rs. 20,000/- for tower height between 5 - 20
meter
Rs. 100/- for each meter in excess of 20 m.
(vi) Rs. 5,000/- for project Cost of 5 million and
Rs. 100/- for each million in excess
Processing Fees
(i) Floor area (sq.m.) Rs. Cts.
Below 45 500.00
45-90 1,000.00
91-180 1,250.00
181-270 1,500.00
271-450 1,750.00
451-675 2,000.00
676-900 2,250.00
Above 900 2,250.00
Rs. 500/- for every
90 sq.m. in excess
of 901 sq.m.
Processing Fees
(i) * Land Below 1000 sq.m. Rs. 2,000.00
* Between 1001- 5000 sq.m. Rs. 5,000.00
* Between 5001 - 10,000 sq.m. Rs. 10,000.00
* Rs. 1,000 for every 1,000 sq.m. in excess of
10,001 sq.m.
(i) Residential Commercial and
Others
(Per linear in) (Per linear in)
Rs. 2,000.00 Rs. 5,000.00
(i) Rs. 1,500.00 Rs. 3,000.00
96
(iv) Reclamation of Low Lying
lands/Paddy Lands
(v) Erection of
Telecommunication Antenna
Towers
(vi) Special Development Projects
4. Issues of Certificate of
Conformity (Certificate of
Conformity should be
obtained for all development)
(i) Land Sub Division
(ii) * Residential Construction
* Commercial and other
construction
(iii) Erection of Boundary
Walls/ Retaining
(iv) Reclamations of Low Lying
lands / paddy lands
(v) Erection of
Telecommunication
antenna towers
C
C
C
D
* Land Area less than 150 sq.m. Rs. 2,500.00
* Between 151 and 300 sq.m. Rs. 5,000.00
* Rs. 3,000/- for each 150 sq.m. in excess of 301
sq.m.
* Height between 5-20 m Rs. 20,000.00
* Rs. 100/- for each 01 meter in excess of 20 m
* Small Scale Projects Rs. 10,000.00
Less than 5 Million Rupees
* Medium Scale Project Rs. 50,000.00
Between 5-50 Million Rupees
* Large Scale Project Rs. 150,000.00
Above 50 Million Rupees
Fees for granting Certificate of Conformity
Rs. 1,000/- for first land lot and Rs. 500/- for each
lot in excess
Rs. 3,000/- for below 300 sq.m. floor area and
Rs. 10/- for each sq.m. in excess
Rs. 3,000/- for 100 sq.m. and Rs. 20/- for each
sq.m. in excess
Rs. 1,000/- for 100/- per linear meter and Rs. 10/-
for per linear meter each in excess
Rs. 3,000/- for land and below 150 sq.m. and
Rs. 20/- for each sq.m. in excess
Rs. 20,000/- for towers between 5 m to 20 m in
height and Rs. 100/- for each meter in excess
97
(vi) Special Projects
5. Parking Bays
(Service charges for
parking spaces not
providing within
premises but required
under the UDA
regulations)
(i) Municipal Council
(ii) Urban Council and
Pradeshiya Sabha
6. Covering Approvals
I Sub division of lands without
obtaining necessary approval
II Erection of buildings/
Additions/erections without
obtaining Development
Permits
Stage of Construction
(i) Only foundation work
completed (up to plinth
level)
(ii)Construction up to roof level
(excluding roof)
(iii)Construction including roof
(iv)Construction completed
III Erection of Boundary walls/
Small Scale Rs. 5,000.00
Medium Scale Rs. 10,000.00
Large Scale Rs. 20,000.00
Service Chargers
* Light vehicles and cars Rs. 500,000.00
* Lorries Rs. 1,000,000.00
* Large vehicle including Rs. 2,500,000.00
Containers
* All vehicles Rs. 500,000.00
* All vehicles Rs. 250,000.00
Fees for granting Covering approvals
(i) Rs. 750/- for every Lot
(ii) Residential per sq.m. Commercial and Others
per sq.m.
Rs. 200.00 Rs. 500.00
Rs. 300.00 Rs. 1,000.00
Rs. 400.00 Rs. 1,500.00
Rs. 500.00 Rs. 2,000.00
98
7. Charge for Change of Use of residential unit
(i) Rs. 2,000 per sq.m. to convert a residential unit to any other permitted use,
if the property is located in a Special Primary Residential Zone.
(ii) Rs. 800 per sq.m. to convert a residential unit to any other permitted uses,
if the property is located in any other zone, other than Special Primary
Residential Zone.
8. Additional floor area permitted in excess of prescribed Floor Area Ratio
The Service Charges to be calculated as a percentage of the cost of construction of
the building which will vary from 30% to 7% based on the following factors.
(i) Location of the building
(ii) Infrastructural Status
(iii) Type of development
(iv) Environmental effects
(v) Zoning as per the Development Plan, if any
The building costs that will be taken into consideration for this calculations should
not be less than the following values.
(i) Residential Houses Rs. 20,000.00 per sq.m.
(ii) Residential flats, commercial and office buildings Rs. 30,000.00 per sq.m.
up to 04 storeys
99
Retain walls
IV Reclamation of low lying
paddy lands/
V Erection of
Telecommunication and
Antenna Towers
VI Special Development projects
VII Occupation/usage without
obtaining Certificate of
Conformity
Rs. 400.00 Rs. 400.00
Rs. 5,000/- for every 150 sq.m.
Rs. 10,000/- for every 05 meter in height
Rs. 10,000/- for every 05 million project cost
Rs. 50/- per day
(iii) Residential flats, commercial and office building Rs. 60,000.00 per sq.m.
over 04 storeys
(iv) Light industrial buildings Rs. 45,000.00 per sq.m.
(v) Warehouses Rs. 30,000.00 per sq.m.
9. For Provision of Services, reports or other Service activities.
(i) Transport charges for issuing of Preliminary Planning Clearance,
Development Permits, Certificates of Conformity shall be borne by the
developer. These minimum charges should be calculated on the basis of Rs.
35/- per Kilo Meter from the relevant office up to the proposed site. This rate
is subject to adjustments as per the prevailing fuel costs.
(ii) A minimum service Charge of 10% of the estimated cost of the project for
provision of Special Consultancy services, preparation of layout plans,
preparation of estimates, project planning shall be levied.
(iii) Service Charge levied for granting covering approvals, market value of the
area of the land of the 10% open space requirement in land sub division and
charges levied in lieu of parking space not provided as per the regulations,
shall be deposited in a separate bank account and these monies shall be used
for development of open spaces, parking facilities, improvements to
pavements or common Urban Development Projects.
100
SCHEDULE III
Qualified Person
Column I
Nature of Development
Activity
Column II
Extent of Land
(Where Relevant)
Column III
Specific Task
Requiring Approval of
Qualified Person
Column IV
Qualification/Designation
Required of Qualified Person
1 If the development
activity does not
involve building
work
Exceeding 0.5
Hectares
Site Layout Plan Corporate member of the
Institute of Town Planners
Regulation Compatibility
Corporate member of the
Institute of Town Planners
Preparation of Sub
division Plan
Licensed Surveyor and
Leveller
2 If the development
activity does not
involve building
work
Less than 0.5
Hectares
Site Layout Plan and sub
division plan
Licensed Surveyor and
Leveller
Regulation compatibility Corporate member of the
Institute of Town Planners
3 If the development
activity involves
engineering works
(construction of
roads, culverts,
drains)
Certificate stating
engineering works have
been carried out in
conformity with the
specifications in the
permit
Chartered Civil Engineer
4 If the development
activity involves a
sub division or
amalgamation of land
Exceeds 0.5
Hectares
Certificate stating that
the Survey Plan is in
conformity with the
Town Planning
Requirements
Corporate member of the
Institute of Town Planners
5 If the development
activity relates to
building category A
and B
1. Architectural Plan
(Certificate stating
development has been
carried out in
conformity with the
approved plan and
permit under his
supervision)
Chartered Architect or
Architect registered with the
Architect Registration
Board
2. Structural Design Plan
along with design
calculations (Certificate
stating that foundation
and building are in
accordance with
approved plan and
building is structurally
safe)
Chartered Civil Engineer or
Chartered Structural
Engineer
101
Column I
Nature of Development
Activity
Column II
Extent of Land
(Where Relevant)
Column III
Specific Task
Requiring Approval of
Qualified Person
Column IV
Qualification/Designation
Required of Qualified Person
3. Service Plans (includes
plans relating to the
supply of electricity,
water supply, sewerage,
drainage and rain water
harvesting, fire safety)
The relevant Engineer to the
services provided:-
Chartered Electrical
Engineer, Chartered Civil
Engineer
Chartered Structural
Engineer
Chartered Building Services
Engineer
Chartered Mechanical
Engineer
4. Detailed plan of Air
conditioning or
mechanical ventilation
(For installation,
extension or alteration)
Chartered Mechanical
Engineer
Chartered Electrical
Engineer
6 If the development
activity relates to
buildings of Sub
Category CI of
Category C
Residential up
to 500 sq.m.
Architectural Plan
(Certificate stating
development has been
carries out under his
supervision in conformity
with the approved Plan
and Permit)
Chartered Architect or
Architectural Licentiate,
registered with the
Architects Registration
Board
Non-Residential
up to 300 sq.m.
Structural Design Plan
along with design
calculations (Certificate
stating that building
construction has been
carried out in accordance
with the approved Plan,
under his supervision)
Chartered Civil Engineer or
Chartered Structural
Engineer, Sri Lanka
Institute of Engineers
(SLIE)
Service Plan (Includes
plans related to the supply
of electricity, water,
sewerage, drainage, rain
water harvesting and fire
safety) only, if required by
the Authority at the time of
submitting the application
The relevant Engineer out of
the under-mentioned below:
Chartered Electrical
Engineer, Chartered Civil
Engineer, Chartered Structural
Engineer, Chartered Building
Services Engineer, Chartered
Mechanical Engineer (SLIE)
102
103
Column I
Nature of Development
Activity
Column II
Extent of Land
(Where
Relevant)
Column III
Specific Task
Requiring Approval of
Qualified Person
Column IV
Qualification/Designation
Required of Qualified
Person
Detailed Plan of Air-
conditioning or
Mechanical Ventilation
(For installation,
extension or alteration)
Chartered Mechanical
Engineer
Chartered Electrical
Engineer (SLIE)
7. If the development
activity relates to
building of Sub
Category CII of
Category C
Residential up
to 400 sq.m.
Designing and
Certification of Plans
Draught-Person (Building)
at NVQ, Level V
Non-Residential
up to 200 sq.m.
Structural Designs,
Service Designs, Air
Conditioning and
Artificial Ventilation
Relevant Members of the
Sri Lanka Institute of
Engineers
8 If the development
activity relates to
building of Sub
Category CIII of
Category C
Residential up
to 200 sq.m
Non-Residential
up to 100 sq.m.
A certificate confirming
that the building has been
constructed with
structural stability
according to the
approved plan and
building permit
Builder/Owner or any other
person acceptable to UDA
Schedule IV
(In Compliance to the Order – 14)
Form – “A”
Access to Residential Buildings
Number of Units for Residence
Provided by the Road
The Minimum Width
of the Road in Meters
Maximum Length (in
Meters)
Below 5 units for residence 3.0 50
Between 5 – 10 units for residence 4.0 100
Between 10 – 20 units for residence 5.0 -
Above 20 units for residence 8.0 -
Schedule IV
Form – “B”
(In Compliance to the Order – 15)
Access to Non-Residential Buildings
The Maximum Extent of
the Land, Provided
Access by the Road (in
Sq.Mt.) Number of
Blocks
The Maximum Site
Ratio of Each Site
Minimum Width
of the Street (in
Meters)
Maximum
Length of the
Street (in
Meters)
When services provided to
an area more than one
allotment or site and less
than four allotments, an
allotment must be not less
than 300 m2.
2.5 6.0 75
When service provided by
the street to one allotment
or site, the allotment must
be 1500 in square meters
1.5 6.0 200
Schedule V
Form – “A” (In Compliance to the Order – 29)
Standards Relevant to the Spaces for Vehicle Parking
Utilization Area of a Unit –
Sq.Mt.
The Minimum Space
Facilities to Park
Vehicles
1 Residential 175 01
2 Commercial 200 01
3 Government / Semi-Government 125 01
4 Industries 220 01
5 Others 200 01
104
The vehicle parking facilities for special utilizations (under-mentioned) must be as follows.
Utilization Space
Private hospitals and nursing homes One vehicle parking space per 20 m2
Consultant rooms 6 vehicle parking space per 10 m2
Medical laboratories One vehicle parking space per 10 m2
Outpatient division One vehicle parking space per 5 m2
Private schools / International schools One vehicle parking space per 20 m2
Private schools / Higher education institutions One vehicle parking space per 30 m2
Pre-schools and day care centers One vehicle parking space per 10 m2
Private tuition classes One vehicle parking space per 20 m2
Places only meal issued (Take away) One vehicle parking space per 20 m2
Canteens One vehicle parking space per 10 m2
Cinemas The higher extent from
One vehicle parking space per 10 m2
or
One space per 20 seats
Multi-Purpose halls One vehicle parking space per 5 m2
Libraries One vehicle parking space per 50 m2
Supermarkets One vehicle parking space per 10 m2
Fashion centers One vehicle parking space per 10 m2
Schedule V
Form – “B”
(In Compliance to the Order – 29)
Width of Aisles Between Vehicle Parking Cages
Vehicle Parking
Angle
Only One Direction
Running and One
Side Parking
Parking in Both
Sides
Running to
Both Directions
1 2 3 4
In parallel 3.6 3.6 6.0
To 300 3.6 4.2 6.3
To 450 4.2 4.8 6.3
To 600 4.8 4.8 6.6
To 900 6.0 6.3 7.2
Note : 1. The details stated in 1, 2, 3 above doesn‟t relevant to containers/lorries.
The space required above for containers/lorries may determine by the Authority after
taking into consideration of the industry‟s nature.
105
Schedule VI
Form – “A”
(In Compliance to the Order – 37)
The Clear Interior Dimensions of Rooms
Room Minimum
Extent (in
Sq.mt.)
Minimum
Length (in
Meters)
Minimum
Width (in
Meters)
(i) When only one room is available in
a residing unit
12.0 4.0 3.0
(ii) When more than one room are
available in a residing unit
(a) First room
(b) Additional room
10.0
8.0
-
-
2.4
2.4
(iii) In a non-resident building 7.5 - 2.4
(iv) (a) Kitchen
The kitchen‟s „Alcova” 6.0 -
0.9
1.8
0.4
Schedule VI
Form – “B”
(In Compliance to the Order – 38)
The Clear Interior Dimensions of Bathrooms and Toilets
Room Minimum Width
(in Meters)
Minimum Length
(in Meters)
1 2 3
Bathroom 1.5 1.2
Toilet 1.2 1.2
Bathroom and toilet annexed 1.5 1.7
Schedule VI
Form – “C”
(In Compliance to the Order – 42)
Stairs
Type
Width of
Stairs (cm)
Minimum
Head Height
(meters)
Height of a
Step
Width of a
Step (cm)
(1) (2) (3) (4) (5)
(a) An interior stair used only
for one upstairs
75 2.0 19 22.5
(b) Stairs in a common
building where public
gather
105 2.1 17.5 22.5
(c) All other types 90 2.1 17.5 22.5
106
Schedule VI
Form – “D”
(In Compliance to the Order – 46)
Total Area of Unfettered Counters
Type As a part of total area under each
subject mentioned in I I (for
natural light and ventilation), the
extent must leave by unfettered
counters
Percentage (%) of
the space where
able to open
counters
Column I Column II Column III
(1) Bathrooms and toilets 1/10 100
(2) Vehicle parking garage 1/10 50
(3) Industries and
warehouses
1/10 50
(4) All other rooms 1/7 50
Schedule VI
Form – “E”
In Compliance to the Order – 56
Specifications Regarding Electric Escalator
(i) Electric escalators for buildings consist with five floors or above must be fixed at
least near the main door and suitable places. The capacity for main escalator and
other escalators must be 12 – 16 and 8 – 12 persons respectively.
(ii) Medium speed electric escalators must be fixed for buildings consist with 5 – 10
floors.
(i) High speed electric escalators must be fixed for buildings higher than above.
Schedule VII
(In Compliance to the Order – 58)
Standards Regarding Hygenic Facilities
Utilization Area (in
sq.mt.)
Number of
Toilets
Number of
Wash Basins
All residential building units 150 1 1
Offices / Shops / Institutions 100 Gents 1
Ladies 1
Gents 1
Ladies 1
Cinemas / Vehicle Parks / Auditoriums 100 Gents 1
Ladies 1
Gents 1
Ladies 1
Hotels (Guest Houses) 100 Gents 1
Ladies 1
Gents 1
Ladies 1
Others 100 1 1
107
Schedule VIII
Form – “A”
(In Compliance to the Order – 59)
Utilization of Buildings and Types of Buildings
Utilization Types of Buildings
1. Domestic Homes, multiple residence, flats, adults homes
2. Commercial Office buildings, hotels, tourist lodges, inns, public lodges,
shopping complexes, supermarkets, restaurants, vehicle
parks
3. Technical Industries, workshops, stores, technical institutions,
infrastructure supply centers.
4. Institutional Government buildings, semi-government buildings and other
common buildings.
Form – “B”
Annual Rainfall
(mm)
The Minimum m3 capacity required 100 m
2 in Vehicle Planning Area
and Tough Paving Area
Residence Commercial Technical Institutional
Domestic Flats/Houses
Condominium
1. 750-1,000 1.5 2.5 5 8 10
2. 1,000-1,500 1.5 2.5 3 8 10
3. 1,500-2,000 1.5 2.5 3 5 10
4. 2,000-2,500 1.5 2.5 3 3 5
5. 2,500-3,000 1.5 2.5 2 2 3
6. 3,000-4,000 1.5 2.5 1 1 2
7. 4,000-5000 1.5 2.5 0.5 1 1
8. 5,000-6,000 1.5 2.5 0.5 0.5 0.5
* The rainfall contained in Sri Lanka National Maps Collection published by
Department of Survey was taken into consideration.
Note :- The location‟s nature of ratio obtained by both supplies i.e. the required equivalent
rain water detention, storing and leak, must be decided by the relevant Provincial
Institution after taking into consideration of underground water tabular fluctuation,
existing lands extent, physical features, absorbing capability and soil condition.
108
The required equivalent
rain water detention
principle (m3)
=
Minimum
Volume
X
Total Roof Planning Area and
Tough Paving Area
(Cement Concrete)
Form “C”
The Proposed Provisions for Storing and Distribution of Rain Water
Capacity (m3) Underground Water Leak (m3)
To
tal
Cu
bic
Met
ers
(m3)
Ab
ov
e th
e E
art
h
Lev
el
Ea
rth
Lev
el
Bel
ow
th
e E
art
h
Lev
el
Oth
ers
Th
e P
it t
o A
bso
rb
Wa
ste
Wate
r
Ea
rth
Wit
ho
ut
To
ug
h P
av
ing
No
n-e
nci
rcle
d
Po
nd
s
Ex
cav
ate
d W
ell
Bo
red
Ho
le
Oth
ers
Schedule IX
Safety Standards for Buildings To Which Can Enter And Used Entered
By Disabled Persons
Standards
Entrance / Exit One entrance/exit door of the building must be left with a sufficient
width to move wheel chairs.
Its‟ width must be 80 cm. or above.
As a principle, the guiding blocks etc… must be established from
entrance/exit doors to reception.
At least one entrance/exit door for one room must make to move for
the persons used wheel chairs and its‟ width must be 80 cm. or
above.
Corridors etc… The corridors‟ width must be 120 cm. by way of able to move for
wheel chair users and sufficient spaces with a standard distance in
every way must keep to turn the wheel chair easily by the user.
If there is a land level change, an equipment or slope way must
establish to remove the said change.
Stairs A palisade must establish
Notification systems must establish in top of the stairs.
Slip Ways Slip ways must establish.
Their width and trend/inclination must be 120 cm. (or above) and
1/12 or above respectively.
When height exceeds 75 cm., the of 150 cm or above must be
provided in ranges of at least 75 cm.
Notification stalls must be established.
Escalator
Equipment
As a principle, an escalator with following specifications for a
building consists with combined site extent in 2000 m2 or above and
two floors or above.
Entrance/exit doors‟ width 80 cm. or above, escalator cabin‟s area
and depth 1.83 m2 (or above) and 135 m or above respectively and
the escalator access hall‟s surrounding dimension must be with a
quadrangle with 150 cm. sides and specifications must be provided
109
(to use the escalator) for wheel chair users and persons who have
visual/hearing diseases.
Toilets At least one toilet per building must be provided to for wheel chair
users.
Vehicle
parking area
One or more vehicle parking spaces/s must be provided for wheel
chair users (minimum width 35 cm.)
The said space must be established and located closely to the
entrance/exit door of vehicle parking area.
Internal way of
buildings
allotments
The internal way to entrance/exit door of a building must be able to
use by wheel chair users and provisions must be provided for
guidance of persons who suffer from hearing/visual diseases.
Its‟ width must not exceed 120 cm. and slip ways etc… must be
provided if there is a site level change.
Stalls to guide persons who suffer from visual diseases must be
provided.
110
Annexure – I
Planning Specifications to Follow for Site Inclination in Residential Zones
1.1 High Density Residential Zone – I
Slope
Inclination
(Decrees)
Minimum
Extent of an
Allotment (m2)
Land
Coverage
(%)
Site
Ratio
Maximum
Height
(Meters)
Minimum
Width of
the Site
Below 20
20-40
40-60
Above 60
150
200
300
No permission
will be granted
for any
construction
66
60
50
-
2.50
1.5
0.75
-
9
6
3
-
5.0
8.0
10.0
-
1.2 Low Density Residential Zone – I
Slope
Inclination
(Decrees)
Minimum
Extent of an
Allotment (m2)
Land
Coverage
(%)
Site
Ratio
Maximum
Height
(Meters)
Minimum
Width of
the Site
Below 20
20-40
40-60
Above 60
300
350
600
No permission
will be granted
for any
construction
66
60
50
-
1.5
1.2
0.5
-
6
6
3
-
6.0
8.0
15.5
-
111
Annexure – II
Main Roads Reservation of Ratnapura Municipal Council Limit
No. Name of the Road
Type
of
Road
Building Limit
from Center of
the Road
ft. m.
1 Ratnapura - Palawela Road (Pothgul Vihara
Mawatha) To Main Bridge
A 50 15
2 Ratnapura - Palawela Road (Pothgul Vihara
Mawatha) From Main Bridge to front
A 40 12
3 Colombo – Badulla Road
i. Colombo – Ratnapura Road
ii. Ratnapura – Balangoda Road
A
A
50
50
15
15
4 Ratnapura – Panadura Road A 50 15
5 Senanayake Mawatha A 50 15
6 Main Street A 50 15
7 Urban Council Place A 50 15
8 Weralupa Old Road (To Bus Stand) A 50 15
9 Bandaranayake Mawatha B 40 12
10 Station Road B 40 12
11 Ratnapura – Karavita Road B 40 12
12 Hidellana Road (To Tea Research Bureau) B 40 12
13 Ratnapura – Wewelwatte Road B 40 12
14 Warehouse Road B 40 12
15 Weralupa Old Road B 40 12
112
Other Roads Reservation of Ratnapura Municipal Council Limit
(30 ft. wide roads)
No. Name of the Road
Type
of
Road
Building Limit
from Center of the
Road
ft. m.
1 Hospital Road C 30 09
2 Weralupe – Kospelawinna Road C 30 09
3 Khemananda Mawatha C 30 09
4 Mudduwa Mawatha C 30 09
5 Mahawala Watta Road C 30 09
6 Church Road C 30 09
7 Dharmapala Mawatha C 30 09
8 Bandarawatta Road C 30 09
9 Mosque Road C 30 09
10 Urban Council Place C 30 09
11 A.C. Atigala Mawatha C 30 09
12 Bodhigira Vihara Road C 30 09
13 Shaylathalarama Mawatha C 30 09
14 Angammana Road C 30 09
15 Sumanajothi Mawatha C 30 09
16 Abeyratne Mawatha C 30 09
17 Batugedara Old Road C 30 09
18 Thanakola Kotuwa Market Road C 30 09
19 Munidasa Kumaratunga Mawatha C 30 09
20 Shaviya Mawatha C 30 09
21 Ketaliyampalla Road C 30 09
22 Ganegoda Road Near Devalaya C 30 09
23 Samagipura Mawatha C 30 09
24 Gnanalankara Mawatha C 30 09
25 Sri Sumana Mawatha C 30 09
26 Ethoya Road C 30 09
27 Goluwavila Road C 30 09
28 Polhengoda Road C 30 09
29 Inner Circular Road C 30 09
30 Outer Circular Road C 30 09
31 Tank Road C 30 09
32 Batugedara Demuwawatha Road C 30 09
33 Frank Hettiarachchi Mawatha C 30 09
34 Rathna Jothi Mawatha C 30 09
35 Urban Council Place 1st Lane C 30 09
36 Hidellana Road C 30 09
113
Other Roads Reservation of Ratnapura Municipal Council Limit
(20 ft. wide roads)
No. Name of the Road
Type
of
Road
Building Limit
from Center of the
Road
ft. m.
1 Batugedara - Bothalewatta Road E 20 06
2 Pompa Kele 2nd
Lane E 20 06
3 Pubudugama - Goluwawila Road E 20 06
4 Grassland Road E 20 06
5 Hidellana – Diviyagallena Road E 20 06
6 Nagarasabhagama Nalanda Ellawala Mawatha E 20 06
7 Penela Watta E 20 06
8 Urumulla Road E 20 06
9 Gnanabhasha Mawatha 2nd
Lane E 20 06
10 Beddegedara Watta Road E 20 06
11 Samagipura 5th
Lane E 20 06
12 Samagipura Vihara Mawatha E 20 06
13 Jayamangalaramaya Road E 20 06
14 Mihindugama 1st Lane E 20 06
15 Mihindugama 5th
Lane E 20 06
16 Pushparama Road 1st Lane E 20 06
17 Goluwawila Lane E 20 06
18 Mahawalawatta 5th
Lane E 20 06
19 Gorokgoda Nedurana Place Road E 20 06
20 Golden Gro Road E 20 06
21 Near Devalaya Cemetery Road E 20 06
22 Saman Devalaya Temple Road E 20 06
23 Angammana Vihara Mawatha E 20 06
24 Saman Place Araliya Mawatha E 20 06
25 Farm Garden Temple Road E 20 06
26 Kumara Place Road E 20 06
27 Hidellana 1st Lane E 20 06
28 Hidellana 2nd
Lane E 20 06
29 Hidellana 3rd
Lane E 20 06
30 Hidellana 4th
Lane E 20 06
31 Hidellana 5th
Lane E 20 06
32 Pothgul Vihara Mawatha 1st Lane E 20 06
33 Polhengoda 2nd
Lane E 20 06
34 Thelwatta Road E 20 06
35 Kanadola Road E 20 06
36 Yali Ipadunagama Road E 20 06
37 Rosemary Garden Road E 20 06
38 Saman Place E 20 06
39 Kolin Chandrawankaya 1st Lane E 20 06
40 Batugedara – Bothalewatta Lane E 20 06
41 Near Devalaya Udawatta Road E 20 06
42 New Hospital Road E 20 06
114
No. Name of the Road
Type
of
Road
Building Limit
from Center of
the Road
ft. m.
43 Guru Peliyagoda Road E 20 06
44 Polhengoda Anicut Road E 20 06
45 Ranaviru Sampath Mawatha E 20 06
46 Kalawathiya Road E 20 06
47 Ranaviru Ajantha Mawatha E 20 06
48 Peththarewatta Road E 20 06
49 Samagipura 2nd
Lane E 20 06
50 Sirisumanagama Kovil Road E 20 06
51 Abhayaraja Mawatha E 20 06
52 Maysamale Road E 20 06
53 Mahawala Batugedara Vihara Mawatha E 20 06
54 Pubudugama 2nd
Lane E 20 06
55 Madoldeniya Road E 20 06
56 Rathnajothi Mawatha Godella Road E 20 06
57 Gorokgoda Road E 20 06
58 Angammana Vihara Mawatha 4th
Lane E 20 06
59 Samagipura 1st Lane E 20 06
60 Samagipura 3rd
Lane E 20 06
61 Angammana Vihara Mawatha 1st Lane E 20 06
62 Bogahawela Road E 20 06
63 Gal Anda Road E 20 06
64 Samagipura Nanda Ellawala Mawatha E 20 06
65 Samagipura 2nd
Lane E 20 06
66 Pompakelaya Kovil Road E 20 06
67 Angammana Hena Road E 20 06
68 Angammana Thalangama Watta Road E 20 06
69 Samagipura Cross Road E 20 06
70 Thenna Watta Road 2nd
Lane E 20 06
71 Galkaduwa Peella Road 1st Lane E 20 06
72 Chitta Vivekarama Mawatha E 20 06
73 Ranaviru Jayasena Mawatha E 20 06
74 Ranaviru Thusitha Mawatha E 20 06
75 Mihindugama 6th
Lane E 20 06
76 Mihindugama 7th
Lane E 20 06
77 Priyani Soyza Mawatha E 20 06
78 Sirisumanagama 1st Lane E 20 06
79 Sirisumanagama 2nd
Lane E 20 06
80 Sirisumanagama 3rd
Lane E 20 06
81 Sirisumanagama 4th
Lane E 20 06
82 Sirisumanagama 5th
Lane E 20 06
83 Sirisumanagama 6th
Lane E 20 06
84 Sirisumanagama 7th
Lane E 20 06
85 Ukthenna Deniya Road E 20 06
86 Elistan Watta Road E 20 06
87 Mihindugama Abhayaraja Mawatha E 20 06
115
No. Name of the Road
Type
of
Road
Building Limit
from Center of
the Road
ft. m.
88 Batugedara Mahawela Cross Road E 20 06
89 Polhengoda Bodhiya Road E 20 06
90 Mihindugama 3rd
Lane E 20 06
91 Mihindugama 2nd
Lane E 20 06
92 Mihindugama 6th
Lane E 20 06
93 Samagipura 6th
Lane E 20 06
94 Sanghamitta Mawatha E 20 06
95 Galkaduwa Peella Road 1st Lane E 20 06
96 Mihindugama Mahawala Watta Cross Road E 20 06
97 Pompa Kelaya 1st Lane E 20 06
98 Rathnajothi Mawatha E 20 06
99 Khemananda Mawatha Bogahawela Road E 20 06
100 Gal Anda Golden Gro By Road E 20 06
101 Katugampitiya 1st Lane E 20 06
102 Samagipura Perera Mawatha E 20 06
103 Gorokgoda By Road E 20 06
104 Thiriwanaketiya By Road E 20 06
105 Sri Prangnananda Mawatha E 20 06
106 Angammana Tank Road E 20 06
107 Ehelapola Mawatha E 20 06
108 Devananda Mawatha E 20 06
109 Shrasthodaya Mawatha E 20 06
110 Weganga Road E 20 06
111 Old Prison Road E 20 06
112 Sagara Palansooriya Mawatha E 20 06
113 Kapugampitiya Road / By Road E 20 06
114 Lane Thediya Road E 20 06
115 Madhurawala Road E 20 06
116 Nambapana Road E 20 06
117 Moragahayata Toilet Road E 20 06
118 Road behind Jem Showroom E 20 06
119 Raththihatenna Road E 20 06
120 Mudduwa Mawatha (Lane) E 20 06
121 Kospelawinna Temple Road E 20 06
122 Kuppayama Road E 20 06
123 Muwagam Kanda Road E 20 06
124 Weralupa Temple Road E 20 06
125 Slaughter House Road E 20 06
126 Rest House Road (Swimming Pool Road) E 20 06
127 Public Cemetery Road E 20 06
128 Sripada Mawatha 1st Lane E 20 06
129 Housing Scheme Roads E 20 06
130 Power House Road E 20 06
131 Municipal Commissioner Quarters Road E 20 06
132 Kekunagaha Godella Road E 20 06
116
No. Name of the Road
Type
of
Road
Building Limit
from Center of
the Road
ft. m.
133 Batugedara Imbulula Road E 20 06
134 Mahinda Mawatha E 20 06
135 Senanayake Mawatha (By Road) E 20 06
136 Batugedara Imbulgoda Road E 15 4.5
137 Outer Circular 1st Lane E 15 4.5
Note:- 1. In addition to this, determination and revision of limits of newly
constructed roads and aforesaid buildings will make by Urban
Development Authority time to time by a notice.
2. Taking into consideration of the land‟s physical features, the Urban
Development Authority may relax, regarding other roads and foot path
above.
Annexure – III
Rivers and Canals Reserves
The river/canal reserve relevant to each rivers and roads will determine from the river‟s
canal‟s bank. The existing rivers and canals reserves in the town are detailed in the
following table.
Name of the River / Canal Reserve (from the bank)
Meters Feet
Kalu Ganga 20 66
Way Ganga 20 66
Katugas Ela 4.5 15
Heel Ela 4.5 15
Dodamangaha Ela 4.5 15
Other un-nominated cannals 3 10
Permission will not be granted for any development work within the zone includes 20
meters indicated as the Kaluganga reserve above table and the high risk zone which mostly
face to annual floods to which may includes additionally. Also, before submit the
application for approval of Ratnapura Municipal Council in respect of all development
works within medium risk zone, it is compulsory to obtain the prior approval for primary
planning of Urban Development Authority.
(The special requirements that must fulfill for the areas face to floods indicated by
Annexure - VIII must also be taken into consideration.)
117
Annexure - IV
Dangerous and Unpleasant Businesses
1. Preparation and refining of productions relevant to following subjects.
i. Muddy areca.
ii. Animal parts and associated impurities.
iii. Bricks and tiles.
iv. Copra, coir and machinery coconut oil.
v. Compost and artificial fertilizers.
vi. Fibres and fibre productions.
vii. Soda.
viii. Chunam.
ix. Mechanical matches, crackers.
x. Rubber.
xi. Graphite.
xii. Skins.
xiii. Tobacco.
xiv. Soap.
xv. Vinegar.
2. Dying of fibre, textile and seasoning of skins.
3. Storages relevant to following subjects except retailing.
i. Animal bones.
ii. Coal or charcoal.
iii. Compost or artificial fertilizers.
iv. Copra.
v. Cotton fibres
vi. Fibres.
vii. Fish.
viii. Mineral oil.
ix. Raw skins.
x. Straws
4. The under-mentioned dangerous and unprotected industries.
i. Quarries, laterite and gravel.
ii. Mining (except permitted zones)
118
Annexure – V
Conserved Buildings
01. Buildings in historical / archaeological and architectural value.
Building‟s Name Assessment Number Location
Fort of Holland 01, 1A, 3, 5, 5A, 7, 9, 11 Wales Road
Police Building 13, 1/1, 15, 15, 17, 21,
21A, 25, 31
Wales Road
Museum (Ehelepola Demesne and
its‟ related whole land extent)
194 Colombo Road
Ratnaputa Young Men‟s Buddhist
Association Building (Buddhist
Palace)
16, 16/1/1 Colombo Road
Sabaragamu Saman Devalaya 183, 09, 31, 49, 32 Panadura Road
Annexure – VI
Proposed Site Ratio
Zone Maximum Site Ratio
High density residential zone 2.5
Low density residential zone 1.5
Mixed residential zone 3.0
Commercial Zone 3.0
Government and Semi-Government Institutions Zone 3.0
Pooja Bhoomi Areas 1.0
Others 0.25
N.B,
UDA has power to decide FAR of Hilly Critical places.
119
Annexure – VII
Reserve Requirement for Mining
Construction Reserve Limits
Meters Feet
Roads (from road‟s center line)
1. Road Development Authority‟s roads
* A roads
* B roads
* C roads
2. Other roads
3. Private roads
Water ways (from the edge)
1. Rivers
2. Canals
Constructions
1. Bridge arches
2. Flats
3. Other buildings
4. Playgrounds
5. Other constructions
*45
*20
*13
*7
*3
10
7
10
20
10
10
3
*150‟0”
*66‟0”
*44‟0”
* 22‟0”
11‟0”
33‟0”
22‟0”
33‟0”
66‟0”
33‟0”
33‟0”
10‟0”
Note
* Excavation of tunnels violating the limits belongs to any external property is prohibited.
120
Annexure – VIII
Special Requirements that must fulfill for Flood Victim Areas
All buildings constructed in this zone must consist at least with two floors.
Construction of walls in the ground floor of aforementioned buildings is not allowed
and it must consist only by towers.
The ground floor can be used only for vehicle parking places or other temporary
tasks.
A Chartered Engineer‟s approval for plans of all buildings constructed in this zone
must be obtained.
It is compulsory to obtain tap water from water supplies for constructions (areas
where water supply available)
Construction of septic tanks for toilets will not be allowed. The toilets must connect
to sewage system. (areas where sewage systems available)
20% from the areas of ground floor must leave as able to open for easy removal of
water in a flood situation. (for existing five floors buildings)
Annexure – IX
Special Requirements that must fulfill for Landslip Victim Areas
A Chartered Engineer‟s approval for plans of all buildings constructed in this zone
must be obtained.
Before to develop the land, the primary plan settlement from Urban Development
Authority must be obtained.
The approval from National Buildings Research Center for land development must
be obtained and the slope cutting must be in compliance to the conditions of above
institution.
The land covering ratio in landslip areas must be in compliance to Annexure – I.
The drains system must be constructed by way of easy water removal and
constructions must be done as to avoid the soil get washed out.
The soil conservation methods to ensure surface safety of slopes must follow and
planting, land surface covering methods must adopt.
The slope cutting must be done by 01 meter distance from adjoining land‟s boundary
ensuring its‟ safety.
Note
* Slope cutting by violating to any external property‟s boundaries or leaving landslip risks
is prohibited.
121
Annexure – X
Zoning Boundaries
(Rathnapura Urban Development Area)
Low Density Residential Zone No. 1
North:
From the meeting point of the intersection of western boundary of Block No. 21 in the Final
Village Plan (FVP) No. 347 and the northern boundary of Ratnapura Municipal Council
boundary; a line drawn north east wards and south east wards, south east wards, east wards,
south east wards, east wards, north east wards, south east wards and north east wards along
the northern boundary of the said Municipal Council limit until it meets the centre line of
Haldola Ela
East:
From the last mentioned point a line drawn south west wards along the centre line of
Haldola Ela until it meets the intersection of northern and eastern point of land Block No.
57 A of Final Village Plan (FVP) No. 347.
South:
From the last mentioned point a line drawn north west wards until it meets the southern
boundary of Block No. 21, thence, a line drawn south west wards and north east wards
along the southern boundary line of the said block until it meets the western boundary of the
said block.
West:
From the last mentioned point a line drawn north west wards, north east wards and north
west wards along the western boundary of said land block until it meets the starting point.
Low Density Residential Zone No. 2
North:
From the intersecting point of the eastern boundary of Special Conservation Zone No. 3 and
northern boundary of Ratnapura Municipal Council; a line drawn north east wards along the
northern boundary of Municipal Council limit until it meets the intersecting point of western
and northern boundary of Special Conservation Zone No. 4.
122
East:
From the last mentioned point a line drawn south wards and east wards along the western
boundary of Special Conservation Zone No. 4 until it meets the eastern boundary of
Ratnapura Municipal Council limit.
South:
From the last mentioned point, a line drawn south west wards along the eastern boundary of
Ratnapura Municipal Council until it meets the eastern boundary of Special Conservation
Zone No. 3.
West:
From the last mentioned point a line drawn north wards and north west wards along the
eastern boundary of Special Conservation Zone No. 3 until it meets the starting point.
Low Density Residential Zone No. 3
North:
From the intersection of the centre line of Katugas Ella Ela and northern boundary of
Ratnapura Municipal Council limit; a line drawn north east wards and south wards along the
northern boundary of Ratnapura Municipal Council limit until it meets the northern
boundary of Lot No. 36 in the Final Village Plan (FVP) No. 347.
East:
From the last mentioned point a line drawn south east wards along the northern and eastern
boundary of the said Municipal Council limit until it meets the northern boundary of Lot
No. 42 in the Final Village Plan (FVP) No. 347; thence, a line drawn south east wards and
south west wards along the northern and eastern boundary of said land block until it meets
the intersecting point of southern boundary of Lot No. 44 in the Final Village Plan (FVP)
No. 347 and eastern boundary of Ratnapura Municipal Council..
South:
From the last mentioned point a line drawn west wards, south wards, north wards and north
west wards along the eastern boundary of Ratnapura Municipal Council limit until it meets
the centre line of Katugas Ella Ela.
West:
From the last mentioned point a line drawn north wards along the centre line of Katugas
Ella Ela until it meets the starting point.
123
Low Density Residential Zone No. 4
North:
From the intersecting point of the eastern boundary of Ratnapura Municipal Council and the
centre line of Mahawalawatta road; a line drawn north east wards, south east wards and
south wards along the eastern boundary of Ratnapura Municipal Council until it meets the
centre line of Helaudakanda Ela.
East:
From the last mentioned point a line drawn south east wards along the eastern boundary of
Ratnapura Municipal Council until it meets the centre line of Ratnapura - Malwala road.
South:
From the last mentioned point a line drawn west wards and north west wards along the
centre line of Ratnapura - Malwala road until it meets the centre line of Mahawalawatta
road.
West:
From the last mentioned point a line drawn north west wards, north wards and north west
wards along the centre line of Mahawalawatta road until it meets the starting point.
Low Density Residential Zone No. 5
North:
From the intersecting point of the centre line of Pettare Dola and western boundary of
Special Conservation Zone No. 6 (Forest Reservation); a line drawn south east wards, south
west wards, east wards, north west wards and south east wards along the western and
southern boundaries of the said Special Conservation Zone No. 6 (Forest Reservation) until
it meets the eastern boundary of Ratnapura Municipal Council.
East:
From the last mentioned point, a line drawn south wards, south east wards and south west
wards along the eastern boundary of Municipal Council limit until it meets the centre line of
Muwantanna road.
124
South:
From the last mentioned point a line drawn north west wards, south wards, south west
wards along the centre line of Muwantanna road until it meets the centre line of
Angammana road.
West:
From the last mentioned point a line drawn north wards, north east wards and north west
wards along the centre line of Angammana road until it meets the centre line of Pettare
Dola; thence, a line drawn north wards along the centre line of the Pettare Dola until it
meets the starting point.
Low Density Residential Zone No. 6
North:
From the intersecting point of eastern boundary of Special Conservation Zone No. 7
(Kanadola Forest Reservation) and the centre line of Pradeshiya Sabha road; a line drawn
south east wards along the centre line of the said Pradeshiya Sabha road until it meets the
centre line of Samagipura road; thence, a line drawn south east wards, north wards and
south east wards along the centre line of the said Samagipura road until it meets the centre
line of Ratnapura - Karawita road.
East:
From the last mentioned point a line drawn south east wards, south wards and south west
wards along the centre line of Ratnapura - Karawita road until it meets the centre line of
Dikhena Dola; thence, a line drawn south east wards along the centre line of the Dikhena
Dola until it meets the southern boundary of Ratnapura Municipal Council limit.
South:
From the last mentioned point a line drawn south wards, west wards, south east wards,
south west wards, west wards and north west wards along the southern boundary of
Ratnapura Municipal Council limit until it meets the centre line of Ratnapura - Karawita
road.
West:
From the last mentioned point a line drawn north west wards along the western boundary of
Ratnapura Municipal Council limit until it meets the southern boundary of Special
Conservation Zone No. 7; thence, a line drawn north east wards along the southern and
eastern boundaries of the Special Conservation Zone No. 7 until it meets the starting point.
125
High Density Residential Zone No. 1
North:
From the intersection of the centre line of Hidallana - Karapincha road and northern
boundary of Ratnapura Municipal Council limit; a line drawn north east wards and east
wards along the northern boundary of Ratnapura Municipal Council limit until it meets the
western boundary of Hidellanayaya paddy land; thence, a line drawn south east wards along
the western boundary of the Hidallanayaya paddy land until it meets the centre line of
Hidallana - Karapincha road.
East:
From the last mentioned point a line drawn south east wards along the centre line of the
Hidallana - Karapincha road to a distance of and south east wards along the western
boundary of Hiddallenayaya paddy land until it meets the northern boundary indicated in
the New Town Plan No. 460 prepared by Survey Mr. G.M. Gunadasa.
South:
From the last mentioned point a line drawn south west wards, north west wards and south
west wards along the northern boundary of New Town Plan No. 460 prepared by
Authorized Surveyor G.M. Gunadasa, until it meets the intersecting point of centre line of
Eksath Mawatha; thence, a line drawn north west wards along the centre line of the Eksath
Mawatha until it meets the western boundary of Ratnapura Municipal Council limit.
West:
From the last mentioned point a line drawn north wards and north east wards along the
western boundary of Ratnapura Municipal Council limit, until it meets the starting point.
High Density Residential Zone No. 2
North:
From the intersecting point of northern boundary of Ratnapura Municipal Council and the
centre line of the old railway line; a line drawn east wards, south wards, east wards, south
east wards and north east wards along the northern boundary of Ratnapura Municipal
Council until it meets the meeting point of the northern and western boundaries of Lot No.
21 in 347 Final Village Plan (FVP); thence, a line drawn south east wards along the western
boundary of the Lot No. 21 in 347 Final Village Plan (FVP) land until it meets the southern
boundary of Lot No. 21 in 347 Final Village Plan (FVP); thence, a line drawn east wards
and north east wards along the southern boundary of the said lot until it meets the southern
boundary of Lot No. 57 in 347 Final Village Plan (FVP); thence, a line drawn south east
126
wards along the southern boundary of Lot No. 57 in 347 Final Village Plan (FVP) until it
meets the western boundary of Special Conservation Zone No. 3.
East:
From the last mentioned point a line drawn south west wards and south east wards along the
western and southern boundaries of Lot No. 55, until it meets the centre line of Katugasella
Ela; thence, a line drawn south west wards, south wards and south west wards along the
centre line of the said Ela until it meets the centre line of old railway line.
South:
From the last mentioned point a line drawn south west wards along the centre line of
Katugasella Ela until it meets the intersecting point of centre line of Ratnapura Outer
Circular road; thence, a line drawn south west wards along the centre line of Outer Circular
road until it meets the centre line of the Weralupe old road (Godawela road); thence, a line
drawn north wards and north west wards along the centre line of Weralupe road until it
meets the centre line of Weralupe - Kospelawinna road; thence, a line drawn west wards
along the centre line of the Weralupe - Kospelawinna road until it meets the centre line of
Heen Ela.
West:
From the last mentioned point a line drawn north west wards along the centre line of Heen
Ela crossing the centre line of Alestine watta road proceed along the centre line of Heen Ela
until it meets the centre line of Ratnapura - Colombo main road; thence, a line drawn north
east wards along the centre line of the Ratnapura - Colombo main road until it meets the
centre line of Goluwavila road; thence, a line drawn north east wards along the centre line
of Goluwavila road until it meets the centre line of old railway line; thence, a line drawn
north wards along the centre line of old railway line until it meets the starting point.
High Density Residential Zone No. 3
North:
From the intersection of the centre line of Mahawalawatta by road and centre line of
Polhengoda road; a line drawn north east wards, south east wards along the centre line of
the said Mahawalawatta by road until it meets the centre line of Malwala - Ratnapura road.
East:
From the last mentioned point a line drawn south east wards along the centre line of
Malwala - Ratnapura road until it meets the eastern boundary of Ratnapura Municipal
Council; thence, a line drawn south east wards along the said boundary until it meets the
right bank reservation of the Kalu Ganga.
127
South:
From the last mentioned point a line drawn south west wards and west wards along the right
bank reservation of Kalu Ganga until it meets the centre line of Ekwala Ela; thence, a line
drawn north west wards along the centre line of the Ekwala Ela until it meets the centre line
of Godigamuwa road.
West:
From the last mentioned point a line drawn north west wards along the centre line of
Ekwala Ela until it meets the centre line of Ratnapura - Malwala road; thence, a line drawn
north east wards along the centre line of the Ratnapura - Malwala road until it meets the
centre point of Mahawalawatta by road; thence, a line drawn north west wards, north east
wards along the centre line of the Mahawalawatta by road until it meets the starting point.
High Density Residential Zone No. 4
North:
From the intersecting point of the left bank reservation of Kalu Ganga and the centre line of
old railway line; a line drawn south east wards and north east wards along the left bank
reservation of Kalu Ganga until it meets the eastern boundary of Ratnapura Municipal
Council limit; thence, a line drawn south east wards along the eastern boundary of the
Ratnapura Municipal Council until it meets the western boundary of Special Conservation
Zone No. 6; thence, a line drawn south east wards along the western boundary of the
Special Conservation Zone No. 6 until it meets the centre line of Pettare Dola.
East:
From the last mentioned point a line drawn south west wards along the centre line of Pettare
Dola until it meets the centre line of Angammana road; thence, a line drawn south wards
along the centre line of Angammana road until it meets the centre line of old railway line.
South:
From the last mentioned point a line drawn north west wards along the centre line of old
railway line until it meets the centre line of Mills road; thence, a line drawn north east wards
along the centre line of Mills road until it meets the centre line of Ehelepola Mawatha;
thence, a line drawn north east wards along the centre line of Ehelepola Mawatha until it
meets the centre line of Angammana road.
128
West:
From the last mentioned point a line drawn north west wards and west wards along the
centre line of Angammana road until it meets the centre line of old railway line; thence, a
line drawn north west wards, north wards along the centre line of old railway line until it
meets the starting point.
High Density Residential Zone No. 5
North:
From the intersecting point of the left bank reservation of Kalu Ganga and southern bank
reservation of Wee Ganga; a line drawn north east wards along the left bank reservation of
Kalu Ganga until it meets the centre line of road extended towards suspension bridge.
East:
From the last mentioned point a line drawn south east wards along the centre line of the
road extended towards suspension bridge until it meets the centre line of Batugedara old
road; thence, a line drawn south east wards along the centre line of the Batugedara old road
until it meets the centre line of Ela indicated in the Town Survey Plan No. L/24/12/2F.
South:
From the last mentioned point a line drawn south east wards along the centre line of the Ela
mentioned in the Town Survey Plan No. L/24/12/2F until it meets the southern river bank
reservation of Wee Ganga.
West:
From the last mentioned point a line drawn north west wards along the southern river bank
reservation of Wee Ganga until it meets the starting point.
High Density Residential Zone No. 6
North:
From the intersecting point of the left bank reservation of Kalu Ganga and the centre line of
Karawita - Ratnapura road; a line drawn south east wards, north east wards and south east
wards along the left bank reservation of the Kalu Ganga until it meets the left bank
reservation of Wee Ganga.
129
East:
From the last mentioned point a line drawn south east wards along the left bank reservation
of Wee Ganga until it meets the southern boundary of Ratnapura Municipal Council limit;
thence, a line drawn south west wards along the southern boundary of the Ratnapura
Municipal Council boundary limit until it meets centre line of Ath Oya.
South:
From the last mentioned point a line drawn west wards along the southern boundary of the
Ratnapura Municipal Council boundary until it meets the eastern boundary of Low Density
Residential Zone No. 6; thence, a line drawn north west wards and east wards along the
Low Density Residential Zone No. 6 boundary until it meets the southern boundary of
Mixed Residential Zone No. 4; thence, a line drawn east wards, north west wards, east
wards and south east wards along the southern boundary of the Mixed Residential Zone No.
4 until it meets the eastern boundary of the Mixed Residential Zone No. 4.
West:
From the last mentioned point a line drawn north east wards, south east wards and north east
wards and north west wards along the eastern boundary of Mixed Residential Zone No. 4
until it meets the starting point.
High Density Residential Zone No. 7
North:
From the intersecting point of the western boundary of Ratnapura Municipal Council and
the left bank reservation of Kalu Ganga; a line drawn east wards and south east wards along
the left bank reservation of the Kalu Ganga until it meets the northern boundary of Mixed
Residential Zone No. 4.
East:
From the last mentioned point a line drawn south west wards, north west wards along the
northern boundary of Mixed Residential Zone No. 4 until it meets the western boundary of
the Mixed Residential Zone No. 4; thence, a line drawn south west wards, south east wards,
north west wards, south wards and south east wards along the western boundary of the
Mixed Residential Zone No. 4 until it meets the northern boundary of Low Density
Residential Zone No. 6.
130
South:
From the last mentioned point a line drawn south wards, north west wards along the
northern boundary of the Low Density Residential Zone No. 6 until it meets the southern
boundary of Special Conservation Zone No. 7.
West:
From the last mentioned point a line drawn north east wards and north west wards along the
southern and eastern boundaries of Special Conservation Zone No. 7 until it meets the
western boundary of Ratnapura Municipal Council limit; thence, a line drawn north east
wards along the western boundary of the Ratnapura Municipal Council limit until it meets
the starting point.
High Density Residential Zone No. 8
North:
From the intersecting point of the western boundary of Ratnapura Municipal Council
boundary and the centre line of Ratnapura - Panadura main road; a line drawn north wards
and south east wards along the western boundary of Ratnapura Municipal Council until it
meets the centre line of Ketaliyanpalla road.
East:
From the last mentioned point a line drawn south west wards along the centre line of
Ketaliyanpalla road until it meets the centre line of Ratnapura - Panadura main road; thence,
a line drawn south east wards along the centre line of Ratnapura - Panadura road until it
meets the northern boundary of Sacred Zone; thence, a line drawn south west wards along
the northern and western boundaries of the Sacred Zone until it meets the southern
reservation bank of Kalu Ganga.
South:
From the last mentioned point a line drawn south west wards, north west wards, north east
wards along the southern bank reservation of Kalu Ganga until it meets the centre line of
Kapugampitiya road.
West:
From the last mentioned point a line drawn north east wards, north west wards along the
southern left bank reservation of Kalu Ganga until it meets the starting point.
131
Mixed Residential Zone No. 1
North:
From the intersecting point of the western boundary of Hidellana paddy land and the
northern boundary of Ratnapura Municipal Council area; a line drawn north east wards
along the northern boundary of the Ratnapura Municipal Council area crossing the centre
line of Ratnapura - Colombo main road and drawn towards north east wards, south wards
and north east wards along the Ratnapura Municipal Council northern boundary until it
meets the centre line of old railway line.
East:
From the last mentioned point a line drawn south wards along the centre line of old railway
line until it meets the Goluwawila road.
South:
From the last mentioned point a line drawn south west wards along the centre line of
Goluwawila road until it meets the centre line of Ratnapura - Colombo main road; thence, a
line drawn west wards along the centre line of the Ratnapura - Colombo Main road until it
meets the eastern boundary of Institutional Zone.
West:
From the last mentioned point a line drawn north wards, south east wards, north west wards
along the eastern boundary of Institutional Zone until it meets the northern boundary of
Institutional Zone; thence, a line drawn along the northern boundary of Institutional Zone
until it meets the meeting point of southern and eastern boundaries of High Density
Residential Zone No. 1; thence, a line drawn north west wards along the eastern and
northern boundaries of High Density Residential Zone No. 1 until it meets the starting point.
Mixed Residential Zone No. 2
North:
From the intersecting point of the centre line of Katugasella Ela and the centre line of old
railway line; a line drawn north east wards along the centre line of the Katugasella Ela until
it meets the eastern boundary of Ratnapura Municipal Council; thence, a line drawn south
east wards, east wards, south east wards along the Ratnapura Municipal Council eastern
boundary until it meets the meeting point of northern and eastern boundaries of Low
Density Residential Zone 4; thence, a line drawn south wards along the centre line of
Mahawala Watta road until it meets the centre line of Mahawala Watta by road; thence, a
line drawn south west wards along the centre line of the Mahawala Watta by road until it
meets the northern and western boundaries of High Density Residential Zone No. 3.
132
East:
From the last mentioned point a line drawn south west wards, south east wards along the
western boundary of High Density Residential Zone No. 3 until it meets the centre line of
Ratnapura - Malwatta road; thence, a line drawn south east wards along the centre line of
the Ratnapura - Malwatta road until it meets the centre line of Ekwala Ela; thence, a line
drawn south east wards along the centre line of Ekwalla Ela until it crosses the
Godigamuwa road and drawn south east wards and south wards along the centre line of
Ekwala Ela until it meets the southern bank reservation of Kalu Ganga.
South:
From the last mentioned point a line drawn west wards along the southern bank reservation
of Kalu Ganga until it meets the eastern boundary of Commercial Zone; thence, a line
drawn north west wards, south west wards and north west wards along the eastern boundary
of the Commercial Zone until it meets the northern boundary of Commercial Zone; thence,
a line drawn north west wards along the northern boundary of Commercial Zone until it
meets the centre line of Katugas Ela.
West:
From the last mentioned point a line drawn north east wards along the centre line of
Katugas Ela until it meets the starting point.
Mixed Residential Zone No. 3
North:
From the intersecting point of the centre line of Ratnapura - Badulla road and left bank
reservation of Kalu Ganga; a line drawn east wards along the left bank reservation of Kalu
Ganga until it meets the centre line of old railway line; thence, a line drawn south east
wards along the centre line of old railway line until it meets the centre line of Angammana
road; thence, a line drawn north east wards and south east wards along the centre line
Angammana road until it meets the centre line of Ehelepola Mawatha.
East:
From the last mentioned point a line drawn south west wards along the centre line of
Ehelepola Mawatha until it meets the centre line of Mill‟s road; thence, a line drawn south
west wards along the centre line of the Mill‟s road until it meets the centre line of old
railway line; thence, a line drawn south east wards along the centre line of old railway line
until it meets the centre line of Muwantanna road; thence, a line drawn south east wards
along the centre line of Muwantanna road until it meets the eastern boundary of Ratnapura
Municipal Council limit; thence, a line drawn south east wards along the eastern boundary
133
of the Ratnapura Municipal Council limit until it meets the centre line of Ratnapura -
Badulla road.
South:
From the last mentioned point a line drawn south wards, west wards, north west wards,
south west wards, south east wards and south west wards along the eastern boundary of
Ratnapura Municipal Council until it meets the southern bank reservation of Wee Ganga;
thence, a line drawn north west wards along the southern bank reservation of Wee Ganga
until it meets the centre line of Ela mentioned in the Ratnapura Town Survey Plan No.
(L 24/12/2/F); thence, a line drawn north west wards along the centre line of the Ela
mentioned in the Ratnapura Town Survey Plan No. (L 24/12/2/F) until it meets the centre
line of Ratnapura Old Batugedara road.
West:
From the last mentioned point a line drawn north west wards along the centre line of
Ratnapura Old Batugedara road until it meets the centre line of extended road towards
Suspended Bridge; thence, a line drawn north west wards along the centre line of the road
extended towards suspended bridge until it meets the left bank reservation of Kalu Ganga;
thence, a line drawn north east wards along the left bank reservation of Kalu Ganga until it
meets the starting point.
Mixed Residential Zone No. 4
North:
From the intersecting point of the centre line of Ratnapura - Khemananda Mawatha and the
centre line of Muwagamakanda road; a line drawn south east wards along the centre line of
Khemananda Mawatha until it meets the centre line of Bogahawela road; thence, a line
drawn north east wards along the centre line of the Bogahawela road until it meets the left
bank reservation of Kalu Ganga; thence, a line drawn south east wards along the left bank
reservation of Kalu Ganga until it meets the centre line of the junction of Ratnapura -
Karawita main road and centre line of Mudduwa Ganga Addara road.
East:
From the last mentioned point a line drawn south east wards and south west wards along the
centre of Mudduwa Ganga Addara road until it meets the centre line of Mudduwa Piriven
road; thence, a line drawn north west wards along the centre line of Mudduwa Piriven road
until it meets the centre line of Rosemary Garden road; thence, a line drawn south west
wards along the centre line of the Rosemary Garden road until it meets the centre line of a
Rosemary Garden by road; thence, a line drawn south west wards along the centre line of
the Rosemary Garden by road and extend a straight line up to the meeting point of northern
boundary of paddy land indicated in the Town Survey Plan No. L 24/3/4/F.
134
South:
From the last mentioned point a line drawn along the northern boundary of the paddy land
mention in the Town Survey Plan No. L 24/3/4/F until it meets the western boundary of the
same paddy land; thence, a line drawn south east wards along the western boundary of the
same paddy land until it crosses the Gatangama road and proceed along the western
boundary of the same paddy land until it meets the centre line of Dikhene Dola; thence, a
line drawn north wards, north west wards along the centre line of the Dikhene Dola until it
meets the centre line of Ratnapura - Karawita road; thence, a line drawn north east wards
and north wards along the centre line of Ratnapura - Karawita road until it meets the centre
line of Samagipura Mawatha.
West:
From the last mentioned point a line drawn north west wards along the centre line of
Samagipura Mawatha until it meets the centre line of Nadun Mandiya road; thence, a line
drawn north wards and north west wards along the centre line of Nadun Mandiya road until
it meets the centre line of Gorokgoda road; thence, a line drawn east wards and south east
wards along the centre line of Gorokgoda road until it meets the centre line of Ela; thence, a
line drawn north wards along the centre line of Ela until it meets the southern boundary of
paddy land; thence, a line drawn north wards and south east wards along the southern
boundary of paddy land until it meets the eastern boundary of the said paddy land; thence, a
line drawn north west wards along the eastern boundary of the said paddy land until it meets
the centre line of Muwankanda road; thence, a line drawn east wards along the centre line of
the said road until it meets the starting point.
Mixed Residential Zone No. 5
North:
From the intersecting point of the western boundary of the Ratnapura Municipal Council
and center line of the Kataliyanpalla by road; thence, along the southern boundary of the
Institutional Zone east wards, south wards, south east wards, north east wards and again
south east wards, south wards and south east wards until it meets the center line of the
Ratnapura-Colombo main road; thence, along the centerline of the same main road towards
the north-west until it meets the center line of the Heen Ela.
East:
From the last mentioned point a line drawn south east wards and south wards along the
center line of the Heen Ela until it meets the center line of the Veralupa - Kospelawinna
road; thence, a line drawn east wards along the center line of the Veralupa - Kospelawinna
road until it meets the center line of the Veralupa old road (Godakawela Road); thence, a
line drawn along the center line of the Veralupa old road (Godakawela road) south wards
until it meets the centre line of Katugasella Ela.
135
South:
From the last mentioned point a line drawn south west wards, west wards and again south
west wards along the center line of the Katugaella Ela until it meets the southern bank
reservation of Kalu Gaga; thence, a line drawn along the Conservation boundary of the Kalu
Gaga north west wards until it meets the eastern boundary of the Sacred Zone; thence, a line
drawn along the eastern boundary of the Sacred Zone north west wards, north east wards
until it meets the center line of the Ratnapura - Panadura road; thence, a line drawn along
the center line of the Ratnapura - Panadura road north west wards until it meets the center
line of the Kataliyapalla road; thence, a line drawn along the center line of the Kataliyapalla
road north east wards until it meets the western boundary of the Ratnapura Municipal
Council.
West:
From the last mentioned point a line drawn south east wards, north east wards, north west
wards and north wards along the western boundary of the Ratnapura Municipal Council
until it meets the starting point.
Institutional Zone
North:
From the intersecting point of the centre line of Eksath Mawatha and the Western boundary
of Ratnapura Municipal Council; a line drawn along the center line of the Eksath Mawatha
south east wards until it meets the northern boundary of 460 New Town Plan (Prepared by
Mr. G.M. Gunadasa, Licensed Surveyor); thence, a line drawn along the northern boundary
of the same plan towards north east wards, south east wards, north east wards and south
wards until it meets the center line of Ratnapura - Colombo main road.
East:
From the last mentioned point a line drawn south east wards along the center line of the
Ratnapura - Colombo main road until it meets the northern boundary of the Ratnapura
Seewali Central Collage Land; thence, a line drawn along the northern boundary of the said
land north west wards, west wards until it meets the eastern boundary of the 460 New town
plan (Prepared by Mr. G.M. Gunadasa, Licensed Surveyor); thence, along the eastern
boundary of the said new town plan towards the south until it meets the center line of
Ratnapura - Colombo main road; thence, a line drawn along the center line of the Ratnapura
- Colombo main road towards south east, until it meets the center line of Sirisumanagama
road which is in 460 New town plan (Prepared by G.M. Gunadasa, Licensed Surveyor).
136
South:
From the last mentioned point a line drawn along the center line of the Sirisumanagama
road which is in 460 of new town plan (Prepared by G.M. Gunadasa, Licensed Surveyor)
towards north west until it meets the center line of the Judger‟s quarters road; thence, a line
drawn along the center line of the same road towards north west until it meets the center line
of the Hospital by road; thence, a line drawn along the center line of the same by road
towards south east and south west until it meets the center line of the Hospital road; thence,
a line drawn along the center line of the same Hospital road towards north until it meets the
center line of Kataliyanpalla by road which is going along the southern boundary of
Director of Health Service Office land; thence, a line drawn along the center line of the said
by road towards west until it meets western boundary of Ratnapura Municipal Council.
West:
From the last mentioned point a line drawn along the western boundary of the Ratnapura
municipal council towards north, north-west and north-east until it meets the starting point.
Commercial Zone
North:
From the intersecting point of the center line of the Ratnapura-Colombo main road and the
center line of the Katugasella Ela road; a line drawn along the center line of the Katugasella
Ela road towards north east, north west and east until it meets the center line of Veralupa
old road; thence, a line drawn along the center line of the Veralupa old road towards north
east until it meets the centre line of Inner Circular road; thence, a line drawn along the
center line of the Inner Circular road towards south east until it meets the northern boundary
of the Main bus stand land; thence, a line drawn along the northern and eastern boundaries
of the same bus stand until it meets the center line of the Good shed road; thence, a line
drawn along the center line of the same good shed road towards south east until it meets the
center line of Inner Circular road;
East:
From the last mentioned point a line drawn along the center line of the Inner Circular road
towards east and south until it meets the center line of Good shed road; thence, along the
center line of the said road towards south east until it meets the center line of Colombo -
Badulla road; thence, a line drawn along the center line of the said road towards north east
and south east until it meets southern boundary of Kalu Ganga river reservation, thence, a
line drawn along the southern bank reservation of Kalu Ganga towards south west until it
meets the center line of the Demuwawatha road;
137
South:
From the last mentioned point a line drawn along the southern bank reservation of the Kalu
Ganga towards the north west, south west, and again north west until it meets the center line
of the Ratnapura - Karawita road;
West:
From the last mentioned point a line drawn along the same reservation towards the north
and north-west until it meets the center line of the Katugasella Ela road; thence, a line
drawn along the center line of the same Ela towards east and north east until it meets the
starting point.
Environmental Sensitive Zone – 1 (Paddy Land)
The Hidellanyaya paddy land area is shown as Lot Nos. 5, 6, 7, 8, 9, 10, 11, 12, 13, 152,
153, 156, 158 and indicted in the Final Village Plan No. 342 (Hidellana) of 1937.
Environmental Sensitive Zone – 2 (Paddy Land)
All the paddy lands indicated in Lot No. 84 called Madoldeniyaya North, East, South and
West boundaries are shown in the Final Village Plan No. 347 (Weralupe) of 1937.
Environmental Sensitive Zone – 3 (Paddy Land)
All the paddy land called lower Panidodamgasyaya denoted by Lot Nos. 73 and 74
boundaries are shown in the Final Village Plan No. 347 (Weralupe) of 1937.
Environmental Sensitive Zone – 4 (Paddy Land)
The paddy lands called Panidodamgasyaya (upper) and Deniya indicated as Lot Nos. 101
and 73 boundaries are shown in the Final Village Plan No. 347 (Weralupe) of 1937.
Environmental Sensitive Zone – 5 (Paddy Land)
The paddy lands called Barawadeniyaya (Lot Nos. 51, 52, 59, 69, 110, 111 and 1111/2) and
Deniya portion (Lot No. 115) boundaries are shown in Final Village Plan No. 347
(Weralupe) of 1937.
Environmental Sensitive Zone – 6 (Paddy Land)
The paddy land called Mahadeniyaya indicated as Lot Nos. 130 and 120 (Lot No. 120 being
the present playground) boundaries are shown in the Final Village Plan No. 347 (Weralupe)
of 1937.
138
Environmental Sensitive Zone – 7 (Paddy Land)
A. The paddy land called Nagahamuttetuwa boundaries are shown in the Town Survey
Plan No. L/24/1 DB of 1967.
B. The paddy lands called Madawelyaya and Teldiyawelyaya boundaries are shown in
the Town Survey Plans Nos. L/19/59/2E and L/19/59/4E of 1967.
C. The paddy lands called Godawelyaya and Narangaswelyaya boundaries are shown
in the Town Survey Plans Nos. L/19/59/4E and L/19/60/3DB of 1967.
D. The paddy lands called Rukgasyaya boundaries are shown in the Town Survey Plans
Nos. L/19/60/3DB and L/19/60/3E of 1967.
E. The paddy lands called Mahawelyaya and Aluthaswedduma boundaries are shown
in the Town Survey Plans Nos. L/19/60/4E and L/24/42F of 1967.
Environmental Sensitive Zone – 8 (Paddy Land)
The paddy lands called Godigamuwa Pahala Welyaya and Godigamuwa Ihala Welyaya
boundaries are shown in the Town Survey Plans Nos. L/24/4/2W, L/19/60/3/E and
L/24/4/1E of 1967.
Environmental Sensitive Zone – 9 (Paddy Land)
The paddy land called Pettare Amunayaya denoted as Lot No. 71 boundaries are shown in
the Final Village Plan No. 15 (Batugedara) of 1937.
Environmental Sensitive Zone – 10 (Paddy Land)
A. The paddy lands called Deniyawattayaya donated as Lot No. 124 and
Angammanayaya (Lot No. 168) boundaries are shown in the Final Village Plan No.
15 (Batugedara) of 1937.
B. The paddy land called Ganegodayaya denoted as Lots Nos. 206, 208 209, 210, 266
and 264 boundaries are shown in the Final Village Plan No. 15 (Batugedara) of
1937.
C. The paddy land called Tiriwanaketiyayaya denoted as Lots Nos. 271, 272, 273, 292
and 314 boundaries are shown in the Final Village Plan No. 15 (Batugedara) of
1937.
D. The paddy lands called Dehipitiyawelyaya and Mahawelyaya denoted as Lot Nos.
304, 307, 309, 313, 310, 312 and 297 boundaries are shown in the Final Village Plan
No. 15 (Batugedara) of 1937.
139
E. The paddy land called Halgaswelyaya denoted as Lot No. 169 boundaries are shown
in the Final Village Plan No. 15 (Batugedara) of 1937.
F. The paddy land called Kantheriyanyaya denoted as Lot No. 179 boundaries are
shown in the Final Village Plan No. 15 (Batugedara) of 1937.
G. The paddy land called Hathagalyaya denoted as Lot Nos. 349 and 351 boundaries
are shown in the Final Village Plan No. 15 (Batugedara) of 1937.
Environmental Sensitive Zone – 11 (Paddy Land)
The paddy land known as Panagodayaya denoted as Lot No. 60 boundaries are shown in the
Final Village Plan No. 80 (Mudduwa) of 1937.
Environmental Sensitive Zone – 12 (Paddy Land)
The paddy land known as Ethoyayaya denoted as Lot Nos. 56 and 53 boundaries are shown
in the Final Village Plan No. 80 (Mudduwa) of 1937.
Environmental Sensitive Zone – 13 (Paddy Land)
The paddy lands known as Puranwu paddy tract denoted as Lot No. 63 and Watupitiyayaya
(Lot Nos. 8 and 9) boundaries are shown in the Final Village Plan No. 80 (Mudduwa) of
1937.
Environmental Sensitive Zone – 14 (Paddy Land)
The paddy lands known as Teldiyayaya and Pillawala Amunayaya boundaries are shown in
the Town Survey Plan No. L/24/3/4E of 1967.
Environmental Sensitive Zone – 15 (Paddy Land)
The paddy land known as Lenthadiyayaya boundaries are shown in the Town Survey Plan
No. L/24/3/2E of 1967.
Sacred Area Zone (Maha Saman Devalaya)
The land area indicated in the Plan No. G.L.384/87 and declared as a Sacred Area by
Gazette Notification dated 19th
March 1999 under 21(2) b of the Town and Country
Planning Act is categorized as a Sacred Area under the Zoning Plan of the Ratnapura
Municipal Council Area.
140
Special Conservation Zone 1
Land area comes under the lot no 1 to 68 indicated in plan No. 460 new town plan,
Ratnapura.
Special Conservation Zone 2
Land area depicted as lot No. 305, 308, 309 in plan No. 460 new town plan, Ratnapura.
Special Conservation Zone 3 (Katugasella Reservation)
North:
From the intersecting point of the center line of the Haldola which is depicted in F.V.P No.
347 and the northern boundary of the Ratnapura Municipal Council; a line drawn north east
wards along the northern boundary Ratnapura Municipal Council until it meets the center
line of No. 54 F.V.P. 347.
East:
From the last mentioned point along the center line of the same stream south east wards,
east wards again south east wards and south wards until it meets the intersection point of the
eastern boundary of Ratnapura Municipal Council.
South:
From the last mentioned point along the eastern boundary of the Ratnapura Municipal
Council south east wards, south wards and south west wards until it meets the intersection
point of the northern boundary of F.V.P 347 of Lot No. 114 land; thence, along the southern
boundary of the Lot No. 55 of same plan north west wards, south west wards again south
west wards until it meets the intersection point of center line of the Haldola.
West:
From the last mentioned point along the center line of the Haldola north west wards, north
east wards and again north west wards and north east wards along the center line of the
Haldola, area within the line drawn towards the starting point.
Special Conservation Zone 4 (Katugasella Reserve)
North:
By considering starting point as a meeting point of the center line of the by road which is
depicted in no. 51 of F.V.P 347 and northern boundary of the Ratnapura Municipal Council;
141
thence, along the northern boundary of the same north east wards until it meets the
intersection point of the centerline of Katugasella stream.
East:
From the last mentioned point along the center line of the same stream south wards until it
meets the intersection point of the eastern boundary of the Ratnapura Municipal Council.
South:
From the last mentioned point along the southern boundary of the Ratnapura Municipal
Council south wards, south west wards until it meets the intersection point of the center line
of the road which is depicted in No. 51 of F.V.P 347.
West:
From the last mentioned point, along the center line of the by road which is depicted in no.
51 of same towards the west and north wards until it meets the area within the line drawn
towards the starting point.
Special Conservation Zone 5 (Pompakele Reservation)
The Pompakele reservation boundaries are indicated in the Survey Plan No. 355 under lot
Nos. PP3909/1 to PP3609/5 prepared by Licensed Surveyor Mr. K. Nandasena in 1992.
Special Conservation Zone 6 (Angammana Reservation)
North:
From the intersecting point of the Southern boundary of the Ratnapura Municipal Council
Area and the centre line of Umandola, a line drawn Eastwards and then South Eastwards
along the Southern boundary of the Ratnapura Municipal Council limits until it meets the
meeting point of the Eastern boundary and Southern boundary of forest land, Lot No. 144
shown in the resurveyed Final Village Plan No. 15 of 2003.
East:
From the last mentioned point, a line drawn South Westwards and North Westwards along
the Southern boundary of the Ratnapura Municipal Council limits, and continuing further
South Westwards along said Municipal Council boundary until it meets the meeting point of
the Southern and Western boundaries of Forest Lot No. 58 in the afore mentioned F.V.P.
No. 15.
142
South:
From the last mentioned point, a line drawn south wards and south west wards along the
southern boundary of the Ratnapura Municipal Council Area up to the southern and western
boundaries of Forest Lot No. 835 in the above stated F.V.P., and continuing north east
wards and north west wards along the same west boundary up to the meeting point of the
eastern and southern boundaries of Forest Lot No. 833 in the said F.V.P.; from there a line
drawn west wards along the southern boundary of the same Lot up to the meeting point of
the southern and eastern boundary of Lot No. 834 in the said F.V.P; from there south west
wards along its south boundary and north west wards along its western boundary up to the
meeting point of the southern and western boundaries of Forest Lot No. 833; from there
north west wards along the western boundary of the same Lot, then east wards along the
northern boundary until it meets the southern and western boundaries of Forest Lot No. 828
of the above mentioned F.V.P.
West:
From the last mentioned point, a line drawn north west wards along the western boundary of
Forest Lot No. 828 in the same F.V.P, then east wards along its northern boundary up to the
eastern boundary of the same Lot; from there continuing it further north wards along the
western boundary of Lot No. 829 on the said F.V.P. up to the meeting point of the southern
and western boundaries of Forest Lot No. 826 in the above F.V.P; from there a line drawn
north west wards along the western boundary of the said Lot and then north east wards up to
western boundary of Lot No. 58 in the above stated F.V.P; from there continuing north west
wards along its western boundary until it meets the starting point to enclose the area.
Special Conservation Zone - 7 (Kanadola Reservation)
North:
Starting from the meeting point of the northern and western boundaries of Lot No. 15
(Aluketiya) in Town Survey Plan No. L/24/3/4DB of 1967 and which is also the topmost
point of Potgul Vihara Kande (triangular point), a line drawn north east wards along the
southern boundary of Ratnapura Municipal Council limits up to the southern boundary of
Primary Residential Zone No. 19 of Zoning Plan (see boundaries of No. 19 in Zoning Plan);
from there continuing south east wards and then east wards along the said southern
boundary until it meets the eastern boundary of the same residential zone.
East:
From the last mentioned point, a line drawn along the western boundary of Teldeniyaya
paddy land shown in Town Survey Plan No. L/24/3/4E of 1967 up to the western boundary
of Primary Residential Zone No. 18 of Zoning Plan (see boundaries of No. 18 in Zoning
Plan) from there continuing south east wards and south west wards along the said western
143
boundary, until it meets the centre line of Pradeshiya Sabha Road (the road running north
west wards from Samagipura Road).
South:
From the last mentioned point, a line drawn south west wards along the western boundary
of Residential Zone No. 26 in the Zoning Plan (see boundaries of No. 26 in Zoning Plan) up
to meeting the Southern boundary of the Ratnapura Municipal Council Area of Authority
from there continuing north west wards along the said boundary until it meets the northern
boundary of Lot No. 15 (Aluketiya) shown in Town Survey Plan L/24/11/2 of 1967.
West:
From the last mentioned point, a line drawn north west wards along the southern boundary
of Ratnapura Municipal Council limits until it meets the starting point.
Special Conservation Zone 8 (New Town Reservation)
North:
From the intersection of the center line of Hospital road and southern boundary of Youth
Service Council land; a line drawn north east wards along the southern boundary of the
same land until it meets the center line of Judge‟s Official Quarters road.
East:
From the last mentioned point a line drawn south east wards along the center line of the
Judge‟s Official Quarters road until it meets the northern boundary of Judge‟s Official
Quarters land; thence along the northern and western boundary of the same land towards the
south-west and south until it meets the center line of Hospital By road.
South:
From the last mentioned point a line drawn west wards and south west wards along the
center line of the Hospital by road until it meets the center line of Hospital road;
West:
From the last mentioned point a line drawn along the center line of the same road towards
the north-west and north until it meets the land area within the line drawn towards the
starting point;
144
Kalu Ganga Reservation
Right Bank Reservation
Starting from the point where the centre line of Kalu Ganga and the Eastern boundary of the
Municipal Council limits, a line drawn along the said boundary towards the right bank of
Kalu Ganga; from there a line drawn parallel to the river bank lying at a distance of 66 feet
(20 metres), the line being drawn south west wards, north west wards and east wards, up to
meeting the western boundary of the Ratnapura Municipal Council limits to enclose the
designated area.
Left Bank Reservation
Starting from the point of intersection of the centre line of Kalu Ganga and the eastern
boundary of the Ratnapura Municipal Council limits, a line drawn towards the left bank of
Kalu Ganga; from there a line drawn at a distance of 33 feet (10 metres) and parallel to the
right bank, south west wards and then north west wards until it meets the western boundary
of the said Municipal Council limits to enclose the designated area.
Wey Ganga Reservation
Right Bank Reservation
From a starting point at 66 feet distance to southeast where southern boundary of Ratnapura
Municipal limit meets the Way Ganga Right Bank to a parallel line drawn north west ward
along the southern boundary of Municipality until it meets the left bank reservation of Kalu
Ganga thence southwestwards along the same reservation until it meets the right bank of
Way Ganga thence south east wards along the same right bank until it meets the starting
point.
N.B.
It is compulsory to get approval from the Urban Development Authority to abundant paddy
lands and marshy lands while it take to the development activities.
145