WW HMI SCADA-02Discover the new Alarmimprovements delivered inWonderware System Platform 2014
Rob KambachProduct ManagerPlatform and AppServer
@InvensysOpsMgmt / #SoftwareRevolution
/Wonderware
/WonderwareHMI
social.invensys.com
© 2013 Invensys. All Rights Reserved. The names, logos, and taglines identifying the products and services of Invensys are proprietary marks of Invensys or its subsidiaries.All third party trademarks and service marks are the proprietary marks of their respective owners.
Rob KambachProduct ManagerPlatform and AppServer
/Wonderware
/Group - HMI/Scada/AppServer
![Page 3: PPT Templateiom.invensys.com/EN/userGroupsPresentationsDallas20… · · 2013-10-24WW HMI SCADA-02 Discover the new Alarm improvements delivered in Wonderware System Platform 2014](https://reader033.vdocuments.site/reader033/viewer/2022042620/5ab899d97f8b9ac1058cd994/html5/thumbnails/3.jpg)
Current state around alarming
Configured alarms per operator
Number of Alarms an operatorcan theoretically respond to
Slide 3
10 per minute per operator
![Page 4: PPT Templateiom.invensys.com/EN/userGroupsPresentationsDallas20… · · 2013-10-24WW HMI SCADA-02 Discover the new Alarm improvements delivered in Wonderware System Platform 2014](https://reader033.vdocuments.site/reader033/viewer/2022042620/5ab899d97f8b9ac1058cd994/html5/thumbnails/4.jpg)
Why did the number of alarms increase?
• Automation evolution (including fieldbus) brought more
accessible information per sensor/actuator
• Alarms are easily configurable now (no more wired) ->
no real cost at engineering or operating time to add alarms
• People (SI/EPC) tend to believe more is better: nothing can
happen without noticing if everything has an attached alarm
Slide 4
• Automation evolution (including fieldbus) brought more
accessible information per sensor/actuator
• Alarms are easily configurable now (no more wired) ->
no real cost at engineering or operating time to add alarms
• People (SI/EPC) tend to believe more is better: nothing can
happen without noticing if everything has an attached alarm
![Page 5: PPT Templateiom.invensys.com/EN/userGroupsPresentationsDallas20… · · 2013-10-24WW HMI SCADA-02 Discover the new Alarm improvements delivered in Wonderware System Platform 2014](https://reader033.vdocuments.site/reader033/viewer/2022042620/5ab899d97f8b9ac1058cd994/html5/thumbnails/5.jpg)
Typical observed behavior
Operator overload leads to :
• Over-acknowledgement to keep managementhappy and control room quieter
• Inhibiting “noisy alarms”
• Missing important alarms
• Not being able to mitigate in proper time
Texaco Pembroke 1994
Slide 5
Operator overload leads to :
• Over-acknowledgement to keep managementhappy and control room quieter
• Inhibiting “noisy alarms”
• Missing important alarms
• Not being able to mitigate in proper time
Piper Alpha North sea 1988
![Page 6: PPT Templateiom.invensys.com/EN/userGroupsPresentationsDallas20… · · 2013-10-24WW HMI SCADA-02 Discover the new Alarm improvements delivered in Wonderware System Platform 2014](https://reader033.vdocuments.site/reader033/viewer/2022042620/5ab899d97f8b9ac1058cd994/html5/thumbnails/6.jpg)
Operators have too many alarms to manage
Slide 6
What can we do?
![Page 7: PPT Templateiom.invensys.com/EN/userGroupsPresentationsDallas20… · · 2013-10-24WW HMI SCADA-02 Discover the new Alarm improvements delivered in Wonderware System Platform 2014](https://reader033.vdocuments.site/reader033/viewer/2022042620/5ab899d97f8b9ac1058cd994/html5/thumbnails/7.jpg)
A set of standards and guidelines
EEMUA 191, Alarm systems a guide to design
Namur NA 102 Worksheet, Alarm Management
NPD YA 711, Principles for alarm design (Norwegianpetroleum doctorate slowly adopted throughout Europeas the standard)
VDI/VDE Guideline 3699 (process control using monitors)
ISA S18.02, Management of alarm systems for the processindustry
Slide 7
EEMUA 191, Alarm systems a guide to design
Namur NA 102 Worksheet, Alarm Management
NPD YA 711, Principles for alarm design (Norwegianpetroleum doctorate slowly adopted throughout Europeas the standard)
VDI/VDE Guideline 3699 (process control using monitors)
ISA S18.02, Management of alarm systems for the processindustry
ANSI/ISA 18.2Management
of AlarmSystems forthe ProcessIndustries
API RP-1167Alarm
ManagementFor Pipeline
Systems
![Page 8: PPT Templateiom.invensys.com/EN/userGroupsPresentationsDallas20… · · 2013-10-24WW HMI SCADA-02 Discover the new Alarm improvements delivered in Wonderware System Platform 2014](https://reader033.vdocuments.site/reader033/viewer/2022042620/5ab899d97f8b9ac1058cd994/html5/thumbnails/8.jpg)
Our VisionTo build a best of class Alarm System that is flexible, robust and
complies to all regulations.
Slide 8
![Page 9: PPT Templateiom.invensys.com/EN/userGroupsPresentationsDallas20… · · 2013-10-24WW HMI SCADA-02 Discover the new Alarm improvements delivered in Wonderware System Platform 2014](https://reader033.vdocuments.site/reader033/viewer/2022042620/5ab899d97f8b9ac1058cd994/html5/thumbnails/9.jpg)
What did we address so far…2014release..- Robustness, we developed a new storage mechanism that is
redundant.
- Severity, we introduced severities as a new indication 1-4
- Aggregation, we aggregate all active alarms throughout our objectmodel so @ any level you can see the current state.
- Introduced a new Animation called alarm border.
- Have pre configured alarm controls that go with the default cabfiles.
- Simplified workflow to store alarms from 21 steps to 1 to 2.
- Have new alarm widgets to use in graphics and navigation.
Slide 9
- Robustness, we developed a new storage mechanism that isredundant.
- Severity, we introduced severities as a new indication 1-4
- Aggregation, we aggregate all active alarms throughout our objectmodel so @ any level you can see the current state.
- Introduced a new Animation called alarm border.
- Have pre configured alarm controls that go with the default cabfiles.
- Simplified workflow to store alarms from 21 steps to 1 to 2.
- Have new alarm widgets to use in graphics and navigation.
![Page 10: PPT Templateiom.invensys.com/EN/userGroupsPresentationsDallas20… · · 2013-10-24WW HMI SCADA-02 Discover the new Alarm improvements delivered in Wonderware System Platform 2014](https://reader033.vdocuments.site/reader033/viewer/2022042620/5ab899d97f8b9ac1058cd994/html5/thumbnails/10.jpg)
What is still to come after 2014
- Global Alarm Shelving based on time and operational permissions.
- State based suppression.
- Flexible messaging
- Navigate from alarms to graphics
- Extend alarm primitive to the field
- Simple KPI index based on EEMUA
Slide 10
- Global Alarm Shelving based on time and operational permissions.
- State based suppression.
- Flexible messaging
- Navigate from alarms to graphics
- Extend alarm primitive to the field
- Simple KPI index based on EEMUA
![Page 11: PPT Templateiom.invensys.com/EN/userGroupsPresentationsDallas20… · · 2013-10-24WW HMI SCADA-02 Discover the new Alarm improvements delivered in Wonderware System Platform 2014](https://reader033.vdocuments.site/reader033/viewer/2022042620/5ab899d97f8b9ac1058cd994/html5/thumbnails/11.jpg)
Storage robustness.Support for- Redundant Engines- Store forward- Redundant Historians- Simplicity, no configuration required.
Slide 11
![Page 12: PPT Templateiom.invensys.com/EN/userGroupsPresentationsDallas20… · · 2013-10-24WW HMI SCADA-02 Discover the new Alarm improvements delivered in Wonderware System Platform 2014](https://reader033.vdocuments.site/reader033/viewer/2022042620/5ab899d97f8b9ac1058cd994/html5/thumbnails/12.jpg)
Architecture Historical
Configured for Hist_02
Configured for Hist_01
Auto_Failover
Slide 12
Configured for Hist_02
Double redundant Historical A&E logging, Application Engines and Historians
![Page 13: PPT Templateiom.invensys.com/EN/userGroupsPresentationsDallas20… · · 2013-10-24WW HMI SCADA-02 Discover the new Alarm improvements delivered in Wonderware System Platform 2014](https://reader033.vdocuments.site/reader033/viewer/2022042620/5ab899d97f8b9ac1058cd994/html5/thumbnails/13.jpg)
Architecture RTAlarm Hot Backup Manager supports Alarm platforms as providers
Slide 13
• Alarm Manager increased memory, modifiable through registry• Fixed the Microsoft session 0 issue that got introduced in Vista,So now multiple Alarm Managers can run as a service.
![Page 14: PPT Templateiom.invensys.com/EN/userGroupsPresentationsDallas20… · · 2013-10-24WW HMI SCADA-02 Discover the new Alarm improvements delivered in Wonderware System Platform 2014](https://reader033.vdocuments.site/reader033/viewer/2022042620/5ab899d97f8b9ac1058cd994/html5/thumbnails/14.jpg)
Simplicity of loggingCheckboxes in the Alarm Severity list of the IDE determine if Alarms get logged.If Historian is defined, no further action is needed.
Slide 14
The Old Process had 17 – 21 error prone steps.Changes in Functionality:• If an alarm is silenced it will still log state changes to the A2ALMDB• New DB A2ALMD to allow easy upgrades DB gets auto created, schema unchanged• Supports domain security and OS based security• Granular, event messages can be turned off
![Page 15: PPT Templateiom.invensys.com/EN/userGroupsPresentationsDallas20… · · 2013-10-24WW HMI SCADA-02 Discover the new Alarm improvements delivered in Wonderware System Platform 2014](https://reader033.vdocuments.site/reader033/viewer/2022042620/5ab899d97f8b9ac1058cd994/html5/thumbnails/15.jpg)
Migration• When moving from new to old typical the alarm DB logger logs
alarms to the WWALMDB, the new DB is called A2ALMDB.
• So systems can co exist and alarm logging for new systems is formigrated systems by default turned off.
• Although the name A2ALMDB is fixed and gets installed by theHistorian configurator, the file name is chosen in a way so the nodename is part of the DB name.
Slide 15
• When moving from new to old typical the alarm DB logger logsalarms to the WWALMDB, the new DB is called A2ALMDB.
• So systems can co exist and alarm logging for new systems is formigrated systems by default turned off.
• Although the name A2ALMDB is fixed and gets installed by theHistorian configurator, the file name is chosen in a way so the nodename is part of the DB name.
• DB Schema did not get changed in this release.
![Page 16: PPT Templateiom.invensys.com/EN/userGroupsPresentationsDallas20… · · 2013-10-24WW HMI SCADA-02 Discover the new Alarm improvements delivered in Wonderware System Platform 2014](https://reader033.vdocuments.site/reader033/viewer/2022042620/5ab899d97f8b9ac1058cd994/html5/thumbnails/16.jpg)
Global Priority to Severity mapping
Slide 16
One location to change and customizable image…
Default Alarm Border Icons
![Page 17: PPT Templateiom.invensys.com/EN/userGroupsPresentationsDallas20… · · 2013-10-24WW HMI SCADA-02 Discover the new Alarm improvements delivered in Wonderware System Platform 2014](https://reader033.vdocuments.site/reader033/viewer/2022042620/5ab899d97f8b9ac1058cd994/html5/thumbnails/17.jpg)
Global defined styles for alarm colorsand borders.
One place to change all apps how they represent Alarms
Slide 17
![Page 18: PPT Templateiom.invensys.com/EN/userGroupsPresentationsDallas20… · · 2013-10-24WW HMI SCADA-02 Discover the new Alarm improvements delivered in Wonderware System Platform 2014](https://reader033.vdocuments.site/reader033/viewer/2022042620/5ab899d97f8b9ac1058cd994/html5/thumbnails/18.jpg)
Alarm Border animation.
Global Icons
Global Styles
Auto Configuration for Field_Attributes or objects
Runtime
Slide 18
![Page 19: PPT Templateiom.invensys.com/EN/userGroupsPresentationsDallas20… · · 2013-10-24WW HMI SCADA-02 Discover the new Alarm improvements delivered in Wonderware System Platform 2014](https://reader033.vdocuments.site/reader033/viewer/2022042620/5ab899d97f8b9ac1058cd994/html5/thumbnails/19.jpg)
Simplicity and IT compliance clientsWindows integrated security can be used
Slide 19
Windows account security (domain based)
![Page 20: PPT Templateiom.invensys.com/EN/userGroupsPresentationsDallas20… · · 2013-10-24WW HMI SCADA-02 Discover the new Alarm improvements delivered in Wonderware System Platform 2014](https://reader033.vdocuments.site/reader033/viewer/2022042620/5ab899d97f8b9ac1058cd994/html5/thumbnails/20.jpg)
Updated Clients- Historical• Defined with the standard Themes and Styles colors• Fonts best Practices HMI Standards• Dynamic Filter tabs• Group By functionality
Slide 20
![Page 21: PPT Templateiom.invensys.com/EN/userGroupsPresentationsDallas20… · · 2013-10-24WW HMI SCADA-02 Discover the new Alarm improvements delivered in Wonderware System Platform 2014](https://reader033.vdocuments.site/reader033/viewer/2022042620/5ab899d97f8b9ac1058cd994/html5/thumbnails/21.jpg)
Update Clients - Runtime• Tabbed filtering• Actual alarm indicators on Tabs• Ack buttons• And styles and themes setup as default
Slide 21
![Page 22: PPT Templateiom.invensys.com/EN/userGroupsPresentationsDallas20… · · 2013-10-24WW HMI SCADA-02 Discover the new Alarm improvements delivered in Wonderware System Platform 2014](https://reader033.vdocuments.site/reader033/viewer/2022042620/5ab899d97f8b9ac1058cd994/html5/thumbnails/22.jpg)
Severity Indication in Runtime andHistory mode within the ALM Grids
Slide 22
![Page 23: PPT Templateiom.invensys.com/EN/userGroupsPresentationsDallas20… · · 2013-10-24WW HMI SCADA-02 Discover the new Alarm improvements delivered in Wonderware System Platform 2014](https://reader033.vdocuments.site/reader033/viewer/2022042620/5ab899d97f8b9ac1058cd994/html5/thumbnails/23.jpg)
Widgets for Alarming
Area Indicator Object or Device Indicator Nav Button Indicator
Slide 23
Field Attribute or reference details
![Page 24: PPT Templateiom.invensys.com/EN/userGroupsPresentationsDallas20… · · 2013-10-24WW HMI SCADA-02 Discover the new Alarm improvements delivered in Wonderware System Platform 2014](https://reader033.vdocuments.site/reader033/viewer/2022042620/5ab899d97f8b9ac1058cd994/html5/thumbnails/24.jpg)
Platform Alarms customizable.
Ability to switch of or change the priority of a Platform comm. alarm
Slide 24
Ability to switch of or change the priority of a Platform comm. alarm
![Page 25: PPT Templateiom.invensys.com/EN/userGroupsPresentationsDallas20… · · 2013-10-24WW HMI SCADA-02 Discover the new Alarm improvements delivered in Wonderware System Platform 2014](https://reader033.vdocuments.site/reader033/viewer/2022042620/5ab899d97f8b9ac1058cd994/html5/thumbnails/25.jpg)