6176 East Molloy Road East Syracuse, NY 13057-0278 Tel: 315-431-7200 Fax: 315-431-7201 E-mail:[email protected] www.ppc-online.com Innovate. Connect. Installation Instructions C. Attach coring tool & stripping tool to drill Compression connectors for AVA7-50, AL7-50, LDF7, LCF 158, LCF 158 JA, & VXL7 KIT-HCG-1-5/8 PPC Tool Kit CC-DF-A7 CC-DF-L7 CC-DF-JA7 SP-158 Prep/Strip Tool Step #1 Step #2 With a few simple steps, PPC compression connectors can be easily and consistently installed on 1-5/8” cable Safety Glasses Always wear safety glasses when operating tool Hack Saw 1-5/8” Frame Set HCG Tool A. Straighten cable and position hacksaw in valley of corrugation and cut off the cable square. B. Insert correct center conductor pin into coring tool and firmly tighten. NOTE: – if using VXL cable use “VXL” pin C. Blade lever will rest flat when cut is complete A. Remove the jacket until outer conductor hits fixed stop. Be sure the cutting blade is positioned over the valley of the corrugation. Use the ball detents as guide. B. Release blade lever and operate drill clockwise and counter clockwise to cut through inner and outer conductor D. Set drill speed to LOW D. Remove coring tool. REV 8.0 Port Seal

Upload: towerdoc

Post on 18-Nov-2014

119 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: PPC 1 5-8 Install Inst

6176 East Molloy Road • East Syracuse, NY 13057-0278 • Tel: 315-431-7200 • Fax: 315-431-7201 • E-mail:[email protected] • www.ppc-online.com

Innovate. Connect.

Installation Instructions

C. Attach coring tool & stripping

tool to drill

Compression connectors for AVA7-50, AL7-50, LDF7, LCF 158, LCF 158 JA, & VXL7

KIT-HCG-1-5/8 PPC Tool Kit

CC-DF-A7

CC-DF-L7

CC-DF-JA7

SP-158 Prep/Strip Tool

Step #1

Step #2

With a few simple steps, PPC compression connectors can be easily and consistently installed on 1-5/8” cable

Safety Glasses

Always wear

safety glasses

when operating

tool

Hack Saw

1-5/8” Frame Set

HCG Tool

A. Straighten cable and position

hacksaw in valley of corrugation

and cut off the cable square.

B. Insert correct center

conductor pin into coring tool

and fi rmly tighten.

NOTE: – if using VXL cable use

“VXL” pin

C. Blade lever will rest fl at when

cut is complete

A. Remove the jacket until

outer conductor hits fi xed stop.

Be sure the cutting blade is

positioned over the valley of the

corrugation. Use the ball detents

as guide.

B. Release blade lever and

operate drill clockwise and

counter clockwise to cut

through inner and outer

conductor

D. Set drill speed to LOW

D. Remove coring tool.

REV 8.0

Port Seal

Page 2: PPC 1 5-8 Install Inst

6176 East Molloy Road • East Syracuse, NY 13057-0278 • Tel: 315-431-7200 • Fax: 315-431-7201 • E-mail:[email protected] • www.ppc-online.com

Innovate. Connect.

Installation Instructions

Step #3

D. Core cable to remove

dielectric until outer conductor

reaches stop on coring tool.

A. Remove cable piece from

the side of the stripping tool.

Remove cable from tool.

B. Properly stripped and cut

cable is ready for dielectric

removal.

Step #4

C. Push connector onto cable

until it reaches the mark on the

cable.

A. Cable is properly cored B. Align outer conductor with

top edge of knurl on back piece

and mark cable in line with end

of connector.

Step #5

C. When fully compressed,

connector back will move away

from alignment mark.

A. Pull or push back the insert to

allow connector/cable to lay fl at

in frame.

B. Make sure connector is fully

seated in frameset (lying fl at).

Press tool trigger to compress

the connector. Do not push on tool/cable during compression.

C. Set drill speed to HIGH

REV 8.0

D. Add port seal to connector

to ensure a moisture proof

connection. The port seal should

sit in the fl at area behind the

threads.

THIS STEP IS REQUIRED TO PROTECT PRODUCT WARRANTY