powerlogic egx300

78
PowerLogic EGX300 Integrated gateway-server for entry-level system monitoring

Upload: matty

Post on 11-Feb-2016

255 views

Category:

Documents


1 download

DESCRIPTION

PowerLogic EGX300. Integrated gateway-server for entry-level system monitoring. Outline. Two parts for training Sales/Market Information Product Information. Sales/Marketing Information Part I. Entry Range Monitoring – Why?. Not every customer needs ION Enterprise or EEM - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: PowerLogic EGX300

PowerLogic EGX300Integrated gateway-server for entry-level system monitoring

Page 2: PowerLogic EGX300

Schneider Electric 2- Division - Name – Date

Outline

●Two parts for training● Sales/Market Information● Product Information

Page 3: PowerLogic EGX300

Schneider Electric 3- Division - Name – Date

Sales/Marketing Information Part I

Page 4: PowerLogic EGX300

Schneider Electric 4- Division - Name – Date

Entry Range Monitoring – Why?

●Not every customer needs ION Enterprise or EEM● Some just want the basics● Keep it simple

●Not every sales person can sell a full function power monitoring system● Requires a lot of training● Long sales cycle● Keep it simple● Use entry range monitoring as a way to boost power meter sales

Page 5: PowerLogic EGX300

Schneider Electric 5- Division - Name – Date

EGX300

●An Integrated Gateway-server? ● What’s that? ● Let’s see…..

Page 6: PowerLogic EGX300

Schneider Electric 6- Division - Name – Date

PowerLogic EGX300Integrated gateway-server

● Use your existing Ethernet network to access basic electrical system data● View data with only a web browser, no power monitoring software needed● Log data onboard the EGX300 for historical system analysis

View device data through a simple

browser – no software needed

EGX300 web page

Trend plots

Data log files

EGX100EGX300 Pull information into web

pages from other PowerLogic gateways (PM8ECC, EGX100)

ION 6200

PM800 Micrologic

Sepam

Page 7: PowerLogic EGX300

Schneider Electric 7- Division - Name – Date

Benefits● Get a view of your complete electrical system including:

● Meters● Circuit breaker control units● Protective relays● Motor controllers● Drives

● Operating on an existing Ethernet network, the PowerLogic EGX300:● Accesses multiple Ethernet devices and gateways across the network and

logs data from connected devices● Simple Ethernet connection with minimal configuration required● Offers high performance and reliable communication● Helps lower installation costs● Provides easy system expansion: Dynamic device additions● Is compliant with industry standards (UL, CSA, FCC, CE)

Page 8: PowerLogic EGX300

Schneider Electric 8- Division - Name – Date

Benefits● View real time data using only a web browser● Analyse basic data from your electrical distribution system for cost allocation

and trending reports● Use the embedded web page creation tool to customise your system data

views and add additional devices● Detect serial devices with device Autodiscovery tool

Page 9: PowerLogic EGX300

Schneider Electric 9- Division - Name – Date

Benefits● Functions as a gateway from Ethernet to serial line devices● Connects up to 64 devices per gateway● Offers field upgradeable firmware● Features Modbus TCP/IP address filtering● Features 512 Mb for onboard data logging

Workstations

Modbus TCPWeb browser

PLCModbus TCP

Master

Example:- PLC allowed access- One workstation not allowed access- Level of access configurable for read-only or full access

Modbus TCP/IP Filtering

Feature controls access to critical devices

Modbus serial line

critical control devices

Page 10: PowerLogic EGX300

Schneider Electric 10- Division - Name – Date

EGX300 user interface – per deviceView real time data per individual device

Page 11: PowerLogic EGX300

Schneider Electric 11- Division - Name – Date

EGX300 user interface – per device

View logged data per device

Page 12: PowerLogic EGX300

Schneider Electric 12- Division - Name – Date

EGX300 user interface – summary views

Overview of all connected devicesOverview of all connected devices

Overview of load current of all devices

Overview of demand current all devices

Page 13: PowerLogic EGX300

Schneider Electric 13- Division - Name – Date

EGX300 and EGX400●Expected Sell Gate: March 2009●The EGX300 will replace the EGX400

● Expected to have a lower CCV, but sell for similar market price● Easier to set up - no additional web page programming software needed for

standard web pages● Same foot print as EGX100 ● Power over Ethernet control power option for easy installation

●But the EGX400 has 2 serial ports and has both fiber & copper Ethernet connections

● The EGX300 can connect to devices via Ethernet and via other gateways, which the EGX400 can not

● An EGX300 + an EGX100 should have about the same cost, or lower, than an EGX400

● Very few customers actually bring fiber to the devices or gateways, but if needed, third party adapters are available

Page 14: PowerLogic EGX300

Schneider Electric 14- Division - Name – Date

Product Information Part II

Page 15: PowerLogic EGX300

Schneider Electric 15- Division - Name – Date

Minimum System Requirements

Although there is NO need to install any software, the computer accessing EGX300 will need to have a browser installed.

We support:●Microsoft Internet Explorer 6.0 or higher

Page 16: PowerLogic EGX300

Schneider Electric 16- Division - Name – Date

Physical Characteristic: Ethernet

● Ethernet● 10/100BaseTx ● Media Type:

●10T/100Tx Auto●10BaseT-HD●10BaseT-FD●100BaseTx-HD●100BaseTx-FD

● Framing: Ethernet II & 802.3 (SNAP)● IP Parameters: Address, Subnet Mask, & Default Gateway● Protocols: HTTP, ModbusTCP/IP, FTP, SNMP (MIB II), SNTP, SMTP● Connector: RJ45 ● Pinout: Industry standard● Supports 48 concurrent ModbusTCP/IP connections● Duplicate IP address detection (FDR basic)

Page 17: PowerLogic EGX300

Schneider Electric 17- Division - Name – Date

Physical Characteristic: Serial

● Serial Line● All lines optically isolated● Physical interface: RS485 4-wire, RS485 2-wire, RS232● Protocols: ModbusRTU, POWERLOGIC (SY/MAX), ModbusASCII, Jbus● Baud: 2400–38400bps (RS485); 2400-57600bps (RS232 ASCII)● Parity: None, Even, & Odd● Response timeout: 0.1 to 10 seconds (default = 3 seconds)● Connector:

●RS485 5 position plugable screw-terminal ●RS232 RJ45

● Pinout:●RS232 Industry standard EIA561 for RJ45

● Note: EGX300 is internally connected: no need to physically connect the EGX300 for two wire mode.

Page 18: PowerLogic EGX300

Schneider Electric 18- Division - Name – Date

Physical Characteristic: Exterior

RJ45 Ethernet port(IEEE802.3af)Control power:

24 Vdc or Power-over-Ethernet (PoE)

LED indicators for Ethernet and serial communications

Recessed reset button

LED indicator for power & status

Page 19: PowerLogic EGX300

Schneider Electric 19- Division - Name – Date

Physical Characteristic: Exterior

RS485 serial port

Bias, Termination, and 2-wire / 4-wire jumper

switches RS232 serial port(RJ45 connector)

Page 20: PowerLogic EGX300

Schneider Electric 20- Division - Name – Date

Transparent Ready {TRe}● Embedded web server provides real-time tabular data views for all

supported device types●Single Device Basic Readings●Summary Device Views

– Circuit Summary– Load Current Summary– Demand Current Summary– Power Summary– Energy Summary

● Advanced users can create custom web views

Page 21: PowerLogic EGX300

Schneider Electric 21- Division - Name – Date

TRe: Setup

● Ethernet & TCP/IP● Serial Port● Remote Device Connections● Device List● Device Logging● Device Log Export● Date and Time● SNMP Parameters● Modbus TCP/IP Filtering● Documentation Links● User Accounts● Web Page Access● Preferences

Page 22: PowerLogic EGX300

Schneider Electric 22- Division - Name – Date

TRe: Setup => Auto Discovery

● EGX300 features the ability to “Auto Discover” devices in its daisy chain

● The EGX300 will not find remote devices; the user will need to define a locate address and remote address

● Look under the device list and scroll to the bottom of the page

● The user needs to setup the right baud rate and settings for this ability to work.

Press to Discover

Page 23: PowerLogic EGX300

Schneider Electric 23- Division - Name – Date

TRe: Setup => Data Export

● Users have three options● Disable● Export via FTP● Export via E-mail

● Users will have to setup logging first before choosing either option of FTP or E-mail

● Uses can now only send “incremental” data versus ALL data with the EGX400

Page 24: PowerLogic EGX300

Schneider Electric 24- Division - Name – Date

TRe: Monitor => Single Device Page

● The EGX300 has the ability to display real time readings from devices.

● The devices can be selected individually

● All data displayed has been scaled and set at factory

● Any unique requests will have to be done as a custom page

Page 25: PowerLogic EGX300

Schneider Electric 25- Division - Name – Date

TRe: Monitor => Summary Pages

Summary Pages are standard with TRe level 2 support.

Users can select ALL or individual pages to be displayed the summary pages.

Pages to be displayed:● Circuit Summary● Load Current● Demand Current● Power● Energy

Page 26: PowerLogic EGX300

Schneider Electric 26- Division - Name – Date

TRe: Monitoring => Logging

● Embedded web server provides user selectable topics per device

● Provides logging function to store data from serial devices on 5, 15, 30, or 60 minute intervals

● Stores up to 152 days (60 minute interval) of recorded readings for up to 32 connected serial devices

● Embedded web server provides a graphical view of stored data logs

● Provides Simple Mail Transfer Protocol (SMTP) to E-mail stored device data logs on user defined intervals

● Provides File Transfer Protocol (FTP) server to access device data logs

● Provides File Transfer Protocol (FTP) client to send device data logs

Page 27: PowerLogic EGX300

Schneider Electric 27- Division - Name – Date

Logging File: Example of CSV

Page 28: PowerLogic EGX300

Schneider Electric 28- Division - Name – Date

Monitor: Trend Plots through logging

Page 29: PowerLogic EGX300

Schneider Electric 29- Division - Name – Date

TRe: Monitoring => Custom Pages

● EGX300 will allow users to transfer their own custom pages

● Custom pages will allow users to have the flexibility to create their own custom solution

Page 30: PowerLogic EGX300

Schneider Electric 30- Division - Name – Date

TRe: Documentation

● As part of TRe, users can transfer documentation or create documentation links

● Users can store up to 512 Mb● The documentation can link to other

devices that have web server capabilities

Page 31: PowerLogic EGX300

Schneider Electric 31- Division - Name – Date

Control

● On the Control page, users can reset the values of their individual devices.

Page 32: PowerLogic EGX300

Schneider Electric 32- Division - Name – Date

Diagnostic

● Users can:● Look at stats for the EGX300● Read devices on this page● Check Communication Connection

● The stats information will be used by design and tech support to analyze the system situation

Page 33: PowerLogic EGX300

Schneider Electric 33- Division - Name – Date

Diagnostic: Accumulative Connections

● Users can click accumulative connections and displayed previous connections

● This is valuable in terms of security to keep track of users who have logged on before.

Page 34: PowerLogic EGX300

Schneider Electric 34- Division - Name – Date

Maintenance Log

● EGX300 provides the ability to record maintenance log files.

● Typical users can record simple text information about system or challenges.

Page 35: PowerLogic EGX300

Schneider Electric 35- Division - Name – Date

Advance Features: Remote Connection

● Under Remote Device Connection, users can setup logging remotely and access devices remotely

Page 36: PowerLogic EGX300

Schneider Electric 36- Division - Name – Date

Favicon

Custom Logo

● Users can customize splash screen, logo, color, and favicon

● Please refer to the white paper for detail specifications

● This will allow Integrators to add more value for their services

Logo

Splash Screen

Page 37: PowerLogic EGX300

Schneider Electric 37- Division - Name – Date

Device Types for Support => Refer to next slides for level of support● ATS48                                                                   ● ATV61                                                                    ● ATV71                                                                   ● CM100/200                                                           ● CM2000                                                                ● CM3000                                                                ● CM4000                                                                ● Enercept                                                                ● Energy Meter● ION6200                                                                ● ION7300● ION7650                                                                ● Micrologic A                                                           ● Micrologic H                                                           ● Micrologic P                                          

● Model98 -modbus● Model98-plogic   ● Motorlogic Plus● Motorlogic Plus II                              ● MVSS/RVSS   ● PM200                                                                 ● PM6-mdbus● PM6-plogic                                                           ● PM700                                                                 

  ● PM800                                                                 ● Sepam 2000                                                        ● Sepam Series 20                                                ● Sepam Series 40                                                ● Sepam Series 80                                                ● TeSys

T                                                                                                             

Page 38: PowerLogic EGX300

Schneider Electric 38- Division - Name – Date

Level of SupportTRE CompatibilityView data

SMS Compatibility Transfer datalogs, waverform captures, device based alarms

ION E Compatibility Transfer datalogs, waverform captures, device based alarms

CM100/200 x x x

CM2000 series x x x

CM4000 series x x x

Enercept x x x

Energy Meter x x x

PM200 series x x x

PM600 series (modbus/powerlogic)

x x x

PM700 series x x x

PM800 series x x x

ION6200 series x x

Page 39: PowerLogic EGX300

Schneider Electric 39- Division - Name – Date

Level of SupportTRE CompatibilityView data

SMS Compatibility Transfer datalogs, waverform captures, device based alarms

ION E Compatibility Transfer datalogs, waverform captures, device based alarms

ATS48 x x *

ATV61 x x *

ATV71 x x *

Model 98 (modbus/powerlogic) x x x

Motorlogic Plus x x x

Motorlogic Plus II x x x

MVSS/RVSS x x x

TeSys T x x *

Sepam 2000 x x x

Sepam 20 x x x

Sepam 40 x x x

Sepam 80 x x x

* Device not supported in ION E

Page 40: PowerLogic EGX300

Schneider Electric 40- Division - Name – Date

Level of SupportTRE CompatibilityView data

SMS Compatibility Transfer datalogs, waverform captures, device based alarms

ION E Compatibility Transfer datalogs, waverform captures, device based alarms

Micrologic A x x x

Micrologic H x x x

Micrologic P x x x

Page 41: PowerLogic EGX300

Schneider Electric 41- Division - Name – Date

Application Architecture

●How to address the following situations:● Two and Four Wire Systems● Remote Access to Other Gateways

Page 42: PowerLogic EGX300

Schneider Electric 42- Division - Name – Date

Two and Four Wire Systems

Ethernet Network

RS-485 (4 Wire) RS-485 (2 Wire)

N < 32

Up to 64 Devices can be view by one EGX300EGX300 can remotely connect to other gateways

Page 43: PowerLogic EGX300

Schneider Electric 43- Division - Name – Date

Remote Access to Other Gateways

EGX300 EGX100

Ethernet

EGX300 can poll EGX100 through Ethernet

Page 44: PowerLogic EGX300

Schneider Electric 44- Division - Name – Date

Obsolescence Plan

● EGX300 will be introduced by Q1 2009

● We will stop selling EGX400 by Q1 2010

● We will have stock to replace existing EGX400 for warranty/repair purposes for about three years

● Special Substitution Use Cases (refer to following slides after):

● Second Serial Port ● Older Systems

Page 45: PowerLogic EGX300

Schneider Electric 45- Division - Name – Date

Second Serial Port

EGX300 EGX100

Ethernet

N <= 32

Up to 64 Devices can be viewed by one EGX300EGX300 can remotely connect to other gateways

N <= 32

Page 46: PowerLogic EGX300

Schneider Electric 46- Division - Name – Date

Legacy Systems

EGX300

Ethernet

4 wire System

2 wire System

CNV100

Page 48: PowerLogic EGX300

Schneider Electric 48- Division - Name – Date

Configuration Kit IF USB ONLY, need converter to serial

Page 49: PowerLogic EGX300

Schneider Electric 49- Division - Name – Date

Accessories - PoE Injector (IEEE 802.3af)

●Active mid-span device with universal power cord

●Contents●Universal power cord (IEC-60320-C13 & IEC-

60320-C14, 3-meters (10-feet)●Plug adapters for Australia, Europe, UK, USA●Instruction sheet

●Ordering Information● TCSEAV0100

●Market Price (average)●$80 (USD)

Page 50: PowerLogic EGX300

Schneider Electric 50- Division - Name – Date

PoE Injector Kit

Page 51: PowerLogic EGX300

Schneider Electric 51- Division - Name – Date

FAQ●Are we limited to the predefine topics already in the logging

section setup?● No, we can add more topics; however, we are limited to logging 12

topics●What type of file formats are supported?

● Most files formats are supported, e.g. jpeg, swf, doc, xls●Can divide the network into 2 segments to get faster response?

● Buy one EGX300 and one EGX100●Do we support other web browsers?

● Our pages can be viewed in other browsers

Page 52: PowerLogic EGX300

Schneider Electric 52- Division - Name – Date

FAQ Continuation

●Do we support ION protocol?● At this time, we do not support ION protocol.

●How much memory does EGX300 support?● 512 Mb

●How many e-mails will be sent from the EGX300 for logging?● The number of e-mails sent will be determine by number of devices logged.

●Does EGX300 support SNMP?● Yes, it supports the standard MIB (II).

Page 53: PowerLogic EGX300

Schneider Electric 53- Division - Name – Date

For more information …

● Please visit www.PowerLogic.com

Page 54: PowerLogic EGX300

Schneider Electric 54- Division - Name – Date

Appendix

●User interface following in the next slides

Page 55: PowerLogic EGX300

Schneider Electric 55- Division - Name – Date

EGX300 user interface – real time data

Page 56: PowerLogic EGX300

Schneider Electric 56- Division - Name – Date

EGX300 user interface – maintenance

Page 57: PowerLogic EGX300

Schneider Electric 57- Division - Name – Date

EGX300 user interface – summary device

Page 58: PowerLogic EGX300

Schneider Electric 58- Division - Name – Date

EGX300 user interface – summary device

Page 59: PowerLogic EGX300

Schneider Electric 59- Division - Name – Date

EGX300 user interface – summary device

Page 60: PowerLogic EGX300

Schneider Electric 60- Division - Name – Date

EGX300 user interface – summary device

Page 61: PowerLogic EGX300

Schneider Electric 61- Division - Name – Date

EGX300 user interface – summary device

Page 62: PowerLogic EGX300

Schneider Electric 62- Division - Name – Date

EGX300 user interface – diagnostics

Page 63: PowerLogic EGX300

Schneider Electric 63- Division - Name – Date

EGX300 user interface – setup

Page 64: PowerLogic EGX300

Schneider Electric 64- Division - Name – Date

EGX300 user interface – setup

Page 65: PowerLogic EGX300

Schneider Electric 65- Division - Name – Date

EGX300 user interface – setup

Page 66: PowerLogic EGX300

Schneider Electric 66- Division - Name – Date

EGX300 user interface – setup

Automatically detect networked devices

• Simplifies initial setup• Promotes easy system

expansion

Page 67: PowerLogic EGX300

Schneider Electric 67- Division - Name – Date

EGX300 user interface – setup

Page 68: PowerLogic EGX300

Schneider Electric 68- Division - Name – Date

EGX300 user interface – setup

Device Logging Choose the logging intervals

Choose from a customizable list of logging topics and log up to 10

Page 69: PowerLogic EGX300

Schneider Electric 69- Division - Name – Date

EGX300 user interface – setup

Page 70: PowerLogic EGX300

Schneider Electric 70- Division - Name – Date

EGX300 user interface

Choose to receive the most up-to-date data or all data sent via email or ftp

Page 71: PowerLogic EGX300

Schneider Electric 71- Division - Name – Date

EGX300 user interface – setup

Password protection and controlled network access ensures data and system security

Repalce with Fake user ID

Page 72: PowerLogic EGX300

Schneider Electric 72- Division - Name – Date

EGX300 user interface – setup

Page 73: PowerLogic EGX300

Schneider Electric 73- Division - Name – Date

EGX300 user interface – setup

Page 74: PowerLogic EGX300

Schneider Electric 74- Division - Name – Date

EGX300 user interface – setup

Page 75: PowerLogic EGX300

Schneider Electric 75- Division - Name – Date

EGX300 user interface – setup

Page 76: PowerLogic EGX300

Schneider Electric 76- Division - Name – Date

EGX300 user interface – basic readings

Page 77: PowerLogic EGX300

Schneider Electric 77- Division - Name – Date

EGX300 user interface – accumulated value

Page 78: PowerLogic EGX300

Schneider Electric 78- Division - Name – Date

EGX300 user interface --