AllbestAllbest Creative Development Ltd. (ALLBEST)Creative Development Ltd. (ALLBEST)
Power Transmission EquipmentPower Transmission Equipment
Technology PortfolioIntegrated Technology and Equipment for Power
Substation & Transmission Line
Substation
Steel Tube Tower for Power Transmission Line
Power Transformer & Distribution Transformer
Pre-installed Transformer Substation
High voltage Power Distribution Cabinet
Low voltage Drawer Type Switch Cabinet
Porcelain Insulator
Arrester & Bushing
Circuit Breaker
Electric Power Fittings
Kilowatt- hour Meter
Technology PortfolioTechnology PortfolioIntegrated Technology and Equipment for Power Integrated Technology and Equipment for Power
Substation & Transmission LineSubstation & Transmission Line
SubstationSubstation
Steel Tube Tower for Power Transmission LineSteel Tube Tower for Power Transmission Line
Power Transformer & Distribution TransformerPower Transformer & Distribution Transformer
PrePre--installed Transformer Substation installed Transformer Substation
High voltage Power Distribution Cabinet High voltage Power Distribution Cabinet
Low voltage Drawer Type Switch Cabinet Low voltage Drawer Type Switch Cabinet
Porcelain Insulator Porcelain Insulator
Arrester & BushingArrester & Bushing
Circuit Breaker Circuit Breaker
Electric Power FittingsElectric Power Fittings
KilowattKilowatt-- hour Meterhour Meter
Integrated Technology and Equipment for Power Substation & Transmission Line
35 KV, 110 KV, 132 KV, 220 KV, (230 KV) and 500 KV
Substation
The substation covers Switchgears, Power transformers, Cast Resin type transformers, insulators, Capacitor Bank, SCADA System ( Integrated Monitoring, Control & Protection system), and etc.
Steel Tube Tower for Power Transmission Line
Power Transformer & Distribution Transformer
Power & distribution transformers with the capacity from 5KVA to 900MVA with the voltage from 110V to 500KV
220KV/110KV/35KV POWER TRANSFORMER
31500- 360000KVANO-FIELD DUAL-WINDING REGULATING VOLTAGE TRANSFORMER
0.11731.0173.10.11774.0360000
0.11637.35150.80.11675.0164.315.7518
300000
0.13535.5127.20.13567.0240000
0.15433.5101.80.15459.0180000
0.15382.589.10.15405.097.411#13.815.75
150000
0.16327.375.10.16346.5120000
0.16272.061.10.16288.066.810.513.811#
90000
0.18208.346.50.18220.550.863000
0.18178.538.80.18189.042.450000
0.20148.833.10.20157.536.240000
12~14
0.20127.528.00.20135.030.6189.26.36.6#10.511#
2X2.5220242
31500
No-loadCurrent(%)
LoadLosses(KW)
No-loadLosses(KW)
No-loadCurrent
(%)
LoadLosses (KW)
No-load Losses (KW)
L. V.(KV)
Tapping
Range of
H.V.(%)
H. V.(KV)
Impedance at Short
Circuit(%)
S-10 Standard ValueS-9 Standard ValueConnection
Symbol
Voltage CombinationRatedCapacity
(KVA)
10KV DISTRIBUTION TRANSFORMER
0.614.502.401600
0.612.801.951250
0.610.301.701000
0.77.501.40800 4.5
0.86.201.20630
0.95.100.96500
1.04.300.80400
1.103.650.67315
1.203.050.56250
1.302.600.48200
1.402.200.40160
1.501.800.34125
0.601.500.29100
1.801.250.2580
1.901.040.2063
2.000.870.1750
4
2.100.600.13
Dyn11or
Yyn0
0.4(+/-)5or
(+/-)2X2.5
66.310
30
LoadLosses (KW)
No-load Losses (KW)L. V.(KV)Tapping Range of H.V.(%)
H. V.(KV)
Impedance at Short Circuit
(%)No-load
Current (%)
LossesConnection
Symbol
Voltage CombinationRatedCapacity
(KVA)
10KV DRY-TYPE CAST RESIN POWER TRANSFORMER
58372606300
570.5
314105000
5626550675010 or10.511
4000
5570.7
2205056703150
1890047702500
530.9
1602040502000
1341029701600 521.01107025001250
927021601000 5178301800800
50541.2
66901570
Yd113 or3.15
66.3
94506 or6.36.610
10.511
630
L. V.(KV)Tapping Range of H.V.(%)
H. V.(KV)
NoiseLPA(AN)
(dB)Uk(%)
Io(%)
Pk(F
class120 oc)(W)
Po(W)
Connection
Symbol
Voltage CombinationRatedCapacit
y(KVA)
ROLLED IRON-CORE TYPE DISTRIBUTION TRANSFORMER
10KV COMPLETE SEAL DISTRIBUTION TRANSFORMER
0.181450016801600
0.181200013701250
0.211030011901000
0.247500980800 4.5
0.276200840630
0.35100670500
0.34300560400
0.333650465315
0.363050390250
0.392600335200
0.422200280160
0.451800235125
0.481500200100
0.54125017580
0.57104014063
0.687011550
4
0.660090
Yyn0or
Dyn11
0.4(+/-)5or
(+/-)2X2.5
66.36.610
10.511
30
LoadLosses (W)
No-load Losses (W)
L. V.(KV)Tapping Range of H.V.(%)
H. V.(KV)
Impedance at Short Circuit
(%)No-load
Current (%)
LossesConnection
Symbol
Voltage CombinationRatedCapacity
(KVA)
SINGLE-PHASE ROLLED IRON-CORE TYPE TRANSFORMER
0.31500200100
0.4126016080
0.5860120504
0.66007530
0.84205520
0.93305015
1.02503510 3.5
1.213025
︱︳00.23(+/-)5
6
6.310
10.511
5
LoadLosses
(W)
No-load Losses (W)
L. V.(KV)
Tapping Range of H.V.(%)
H. V.(KV)
Impedance at Short
Circuit(%)
No-loadCurrent
(%)
LossesConnectio
nSymbol
Voltage CombinationRatedCapacit
y(KVA)
Pre-installed Transformer Substation
Being suitable for the open air power supplies for high buildings, residential areas, factories and mines, hotels, parks, oil fields, air ports and wharfs, railways, marketplaces and provisional facilities, the transformer stations are wildly used in the power distributing system of ring network and power distributing terminals of emanant power transmission net.Structure of Product:
The American type is composed of three major portion, such as the transformer, high voltage chamber and low voltage chamber. Loading switch of V type or T type with two-step fuses is used in high voltage side. It is mounted in the oil tank of transformer. The isolating oil of transformers is utilized as all isolating medium and heat-radiating medium. The inserting components of high voltage cable are used for high voltage side, made in full isolation and full sealing structure. The new type of intelligent fuse and plastic shell air switch are used for low voltage side, which has features of high disjunction ability and in good protecting performance.
Features of The Product:1. Full sealing and isolating structure.2. Small volume and compact structure.3. Cable end can operate under a load of 2000A4. Strong over loading capability5. The case is treated by means of special technology, possessing excellent anti-corrosive ability Good appearance, being harmonized with environment.
American type High/ Low voltage Pre-installed Transformer Substation
Description of the ProductThe compact transformer station is suitable for the open air power suppliers for high buildings, residential areas, factories and mines, parks, oil fields, air port ad wharfs, railways, marketplaces and provisional facilities tec.It can also be used in the power distributing system of ring net work and power distributing terminals of emanant power transmission net.
Structure of ProductThe compact transformer station is composed of three major portions, such as high voltage chamber, transformer chamber and low voltage chamber.
▲ The high voltage side is generally equipped with HXGN26 sulfur hexachloride annular net or vacuum annular net cabinet, which has features of less maintenance, all functions for anti-malfunction, with over loading capacity up to 120%.▲ The performance of transformer can meet the requirement of National standard of S11-M.R. S9-M.R. for oil immersed transformer.▲ The new type of intelligent fuse and plastic shell air switch are used for low voltage side, which has features of high disjunction ability and in good protection performance.▲ The outer shell can be made of steel plate, aluminum and zinc plated materials, which is in good appearance with various varieties.▲ It is a medium product of both cases of American type and European type, it processes the advantages of both cases.
Compact Type High/ Low voltage Pre-installed Transformer Substation
European Type High/ Low voltage Pre-installed Transformer Substation
European type/ American type/Compact transformer stationBeing suitable for the open air power supplies for high buildings, residential areas, factories and mines, hotels, parks, oil fields, air ports and wharfs, railways, marketplaces and provisional facilities, the transformer stations are wildly used in the power distributing system of ring network and power distributing terminals of emanantpower transmission net.Structure of Product:European type sub-station consists of high voltage, transformer chamber and low voltage chamber.▲ High side voltage is generally equipped with annular net cabinet (which can be equipped with production gas, pressed gas,vacuum, SF6 loading switch and fuse protection), and also equipped with vacuum, SF6 fuse, with features of smaller in volume, safe and reliable.▲ Either S11-M.R, S9-M.R oil immersed transformer or SC9,SG10-R dry type transformer is used for the transformer.▲ The new type of intelligent fuse and plastic shell air switch are used for low voltage side, which has the features of high disjunction and good protection performance.▲ The outside shell is made of aluminum allay, high quality steelplate, compound plate etc, the top cover is made in two layers to prevent from heat radiation efficiently.▲ There are automatic winds discharging system and condensation proof device in the transformer body.
High voltage Power Distribution Cabinet
Low voltage Drawer Type Switch Cabinet
This device is suitable for low voltage power distributing system such as power plant, petroleum & chemical industry, metallurgy, textile and high building etc. It is used for power supply system, and also used as the low voltage device for idle work power compensations.
Porcelain Insulator
Disc Suspension Porcelain Insulator (Normal Type)
Applicable standard: GB IEC AS BS
238250Mass per 100pcs (Kgs)
5050Max. RIV at 1 MHz (μV)
7.57.5Test voltage to ground (kV)Radio interference voltage
9090Power frequency puncture voltage (kV)
7575Dry lightning impulse withstand voltage (kV)
5555Dry (kV)
3030Wet (kV)Power frequency withstand voltage
55Impact strength (Min.) (N·m)
11Coupling size
2020Routine tensile load (kN)
4040Rated E&M failing load (kN)
185200Nominal creepage distance (mm)
175190Nominal diameter (D) (mm)
110140Unit spacing (H) (mm)
21Figure No.
U40BU40CClass
XP1-40XP-40CType
Anti-pollution Suspension Porcelain Insulator
Applicable standard: GB IEC AS BS
670660600/670650Mass per 100pcs (Kgs)
50505050Max. RIV at 1 MHz (μV)
10101010Test voltage to ground (kV)Radio interference voltage
120120120120Power frequency puncture voltage (kV)
120120120120Dry lightning impulse withstand voltage (kV)
80808080Dry (kV)
42424242Wet (kV)Power frequency withstand voltage
6666Impact strength (Min.) (N·m)
16161616Coupling size
40403535Routine tensile load (kN)
80807070Rated E&M failing load (kN)
432432400432Nominal creepage distance (mm)
255255280255Nominal diameter (D) (mm)
140146146146Unit spacing (H) (mm)
1121Figure No.
U80BPU80BPU70BLPU70BLPClass
XHP3-80XHP-80XHP5-70XHP-70Type
Line post porcelain Insulator
Applicable standard: IEC 60383
940980700Mass per 100pcs (KG)
150150166Lightening impulse withstand voltage (KV)
655062Power freq.1 min wet withstand voltage (KV)
12.512.54Min Cantilever failing load (KN)
250250220Defect leakage distance (mm)
500530625Nominal creepage distance (mm)
321Figure No.
244622446124413Type
Long-rod Suspension Composite Insulator
Applicable standard: 60383
1000760Mass per 100pcs kg
170213Dry lighting impulse withstand voltage kv
180Mpa.h180Mpa.hPorosity Test kv
70k/15min/3times70k/15min/3timesTemperature loop
16L16LCoupling size
5632Routine tensile load KN
7040Rated mechanical failing Load KN
550863Nominal creepage distance (mm)
180135Nominal diameter (D) (mm)
423438Spacing (H) (mm)
21Figure No.
XB-20/70XB-20/40Type
Pin Type Porcelain Insulator
Applicable standard: ANSI C29.5
1601047058Mass per 100pcs kg
9590705Low-freq. puncture voltage kv
3000250025003000Cantilever strength lb
35352520Normal type μV
40352520Anti radio interference type μVWet flashover
70655035Normal type μV
65554535Anti radio interference type μVDry flashover
Low frequencyFlashover voltage
1401309570Normal type μV
1301108570Anti radio interference type μVNegtive
1101007550Normal type μV
105907050Anti radio interference type μVPositive
Critical impulseFlashover voltage
5500550025002500Normal type μV
50505050Anti radio interference type μV
Mac. RIV. At 1MHz
101055Low frequency test voltage to groundRadio interferencevoltage
1271148657Arcing distance (mm)
229178127102Nominal creepage distance (mm)
4321Figure No.
55-455-355-255-1Class
P-10-MP2-10-MP-6-MP-3-MType
Arrester & Bushing
COMPOUND INSULATION BUSHING COMPOUND INSULATION ARRESTER
METAL OXIDE ARRESTER
Circuit Breaker
Applicable standard: IEC 56 and IEC 694
Electric Power Fittings
GROUNDING FITTINGS
1. Grounding Clamp2. Grounding Rod3. Insulator Pin4. Pole Top Pin
GUY WIRE FITTINGS 1. Wedge Clamp2. Strain Clamp of Compression joint (adjustable type)3. UT Wedge Clamp (adjustable type)4. Shackle
PROTECTION FITTINGS
1. Preformed Armour Rod2. Preformed Armour Rod for Conductor Repairing3. Stockbridge Vibration Damper4. Vibration Damper
SPLICING FITTINGS
1. Splicing Sleeve for Steel Wire (hydraulic compression Type)2. Splicing Sleeve for AAC Conductor (hydraulic compression Type)3. Splicing Sleeve for Insulated Overhead Cable (ABC)4. Splicing Sleeve for AS. Stranded Wire (hydraulic compression Type)5. Splicing Sleeve for Steel Wire (explosive overlap joint)6. Splicing Sleeve for ACSR Conductor (explosive overlap joint)7. Splicing Sleeve for ACSR Conductor (compression with pliers)8. Splicing Sleeve for Aluminium Conducotor (twisting type)9. Splicing Sleeve for ACSR/AS Conductor (hydraulic overlap joint)10. Repair Sleeve for ACSR/AS Conductor (hydraulic overlap joint)11. Repair Sleeve for ACSR, AAC, AAAC Conductor12. Repair Sleeve for Steel Clamp13. Aluminium Parallel Groove Clamp14. Parallel Groove Clamp for Steel Wire15. Wedge Parallel Groove Clamp (ejection type)16. S-Parallel Groove Clamp (compression type)17. C-Shape Copper Wire Clamp (compression type)18. C-Shape Aluminium Wire Clamp (compression type)19. H-Parallel Groove Clamp (Compression type)
LINK FITTINGS
1. Ball Eye2. Ball Eye (perpendicular type, with horn holder)3. Ball Eye (parallel type, with horn holder4. Ball Eye ( horn holder type)5. U Type Ball Eye6. Ball Clevis7. Ball Clevis ( horn holder type)8. Socket Tongue9. Socket Eye10. Socket Clevis11. Socket Clevis (elongated type)12. Socket Thimble 13. Socket Clevis ( Y-type)14. Anchor Shackle15. Shackle16. Twisted Shackle17. Vee Shackle18. Twisted Strap19. Hinge to Tower20. Clevis Eye21. Eye Chain Link (900C shifted)22. Chain Link (forged type)23. Clevis24. Clevis Hinge25. Extension Link26. U-Bolt27. Adjusting Plate28. Sag Adjustor Plate29. Yoke Plate30. Double Yoke Plate31. Turnbuckle
SUSPENSION CLAMP
1. Suspension Clamp (trunnion type)2. Suspension Clamp (envelope type)3. Suspension Clamp for Twin Jumper Conductors4. Suspension Clamp (tower top clamp & bracket)5. Suspension Clamp (envelope type)6. Suspension Clamp (trunnion type)7. Suspension Clamp (carried-up type)8. Suspension Clamp (hang-down type)9. Suspension Clamp (abrasion-proof type)10. Suspension Clamp for Jumper Conductor11. Top Clamp for Horizontal Post InsulationAluminium Alloy Suspension Clamp (envelope type)
STRAIN CLAMP
1. Dead End Clamp for ACSR Conductor (compression type)2. Compression Dead-End Clamp (compression type)3. Dead End Clamp for ACSR Conductor (hydraulic compression type)4. Aluminium Alloy Strain Clamp (bolted type)5. Malleable Iron Strain Clamp (bolted type)6. Strain Clamp (bolted type)7. Strain Clamp (straight line type)8. Aluminium Alloy Strain Clamp (straight line type)
Kilowatt- hour Meter
Single-phase electronic prepayment kilowatt-hour meter
Single-phase electronic prepayment kilowatt-hour meterDDSF2000 Single-Phase Static Meter with Multi-rate Calculation FeatureKey Specifications/Special Features:Single-phase multi-rate watthour meter is a new generation electric energy measuring meterIt uses two meters respectively to record the electric energy atflat and valley positions and with additional infrared interface.Main functions: Metering function: time-sharing metering wattful energy,2 rates, 8 time periodsDouble meters respectively record the accumulative power consumption of two ratesOnboard infrared communication function for use with palmtop computer for meter setting and readingPulse output: provided with energy pulse output function, used forchecking meter and collecting power consumption dataPrimary Competitive Advantages: Price, Reputation, Prompt Delivery
Technical Data of Kilowatt-hour meter model DDSF2000
2kg approNet weight
More than 15 yearsWorking life
170?25?14mmOutside dimensions
≥1000mAhBattery capacity
Class2.0Accuracy class
≤0.5S/d(23 degrees Celsius)Clock Accuracy
≥10 yearsData save period under continuous power cut
23℃S Reference temperature
Not more than 2W(8V.A)Total power loss
8KVMaximum impulse voltage
70% to 120%Limit operating voltage range
-10 degrees Celsius to 55 degrees CelsiusLimit operating temperature range
50Hz?%Rated frequency
220V 230V 240VRated Voltage
2.5(10)A 5(20)A 10(40)A 15(60)ABasic current Ib(Maximum current)
DDSF2000Model
Three-phase, Four-wire static kilowatt-hour meter
Primary Competitive Advantages:PriceQualityReputationPrompt DeliveryMain Export Markets:WorldwideThis series watt-hour meters feature has high accuracy, wide range load, and stable and reliable operation, which are required by modern watt-hour meters and
Technical Data of Kilowatt-hour meter model DT962
3781gNet weight
More than 20 yearsWorking life
273?/SPAN>172?/SPAN>125mm(Imax≤40A)279?/SPAN>172?/SPAN>125mm(Imax>40A)Outside dimensions
Class2.0Insulation
Class2.0Accuracy class
8.9?0-4N.mTated torque
<1.4W <5VAPower loss of voltage coil
6KVMaximum impulse voltage
14.85r/minBasic revolution r/min
≤0.005IbStarting current
50HzRated frequency
3?20/380V 3?30/400V 3?40/415VRated Voltage
1.5(6)A 3(6)A 5(20)A 10(40)A 15(60)A20(80)A 30(100)A
Basic current Ib(Maximum current)
DT962Model
Single-phase static meter with multi-rate calculation feature
w/Bi-Directional MeasurementBi-directional measurement of single AC active energy.Logical resistance to running with no-load. Photoelectric isolated pulse output function for easy digital collection.Resistance to tampering and attempted theft:1.Short circuit of inlet and outlet wire.2.Exchange Inlet and outlet wire3.The application of magnetic fields outside meter.4.Incline the meter.High accuracy, high stability, no need of reaular calibration. Wide test range, perfect over-load abiliy. Perfect ability of bearing over -voltage.high reliability design and workmanship:1.Uses industrial-grade and international brand name electronic components, using less power in large range2.SMT manufacturing workmanship.3.Long time high temperature aging workmanship workmanship.Lower power cinsumption.Lower starting current.
Technical Data of Kilowatt-hour meter model DDS188
450gNet weight
More than 30 yearsWorking life
150?12?6mmOutside dimensions
Class2.0Accuracy class
2VAPower loss of voltage coil
≤0.004IbStarting current
50Hz 60HzRated frequency
220V 230V 240VRated Voltage
15(60)A
15(75)A10(40)A
10(60)A10(50)A5(20)A
5(30)A5(25)A2.5(10)ABasic current Ib
(Maximum current)
DD202-6DDS188DDS188Model
ServiceService
Advanced and reliable technology & engineeringProcurement, manufacture, and delivery of the goodsProject managementConstruction, installation, and commissioningTechnical serviceTraining programService after completion of the projectFinancing assistance and export creditOther services and functions upon request