power monitoring technology using smart power meters and data loggers
TRANSCRIPT
Power Monitoring Technology Training
Maria Lemone, Sales ManagerICP DAS USA, Inc.
[email protected] x105www.icpdas-usa.com
Making Data Acquisition Easy
Power Monitoring Technology | Maria Lemone | 1/9/15
Agenda
Making Data Acquisition Easy
• Energy Meter Technology
• Solar Monitoring Systems
• Power Generators
• Local HMI's for Displaying Power Data
• Using Controllers for Saving Energy
• Energy Management using SCADA Software
• Web Page Dashboard Information Systems
Power Monitoring Technology | Maria Lemone | 1/9/15
Making Data Acquisition Easy
ICP DAS USA
• ICP DAS was established in 1993
• Headquartered in Hsinchu, Taiwan
• ICP DAS USA was launched in 2001
Click here to Learn More…
Power Monitoring Technology | Maria Lemone | 1/9/15
Energy Meter Technology
Making Data Acquisition Easy
• Smart Power Meters give you access to real-time energy
usage for single-phase and three-phase power
measurement.
• Support Modbus RTU, Modbus TCP, CANopen
protocols
• Energy meters are compact, powerful and flexible for
many different kinds of applications.
Power Monitoring Technology | Maria Lemone | 1/9/15
Learn more…
Modbus RTU Power Meters
Making Data Acquisition Easy
PM-3112
2 Loops single-phase Smart Power Meter, supports Modbus RTU protocol. RS-485 Interface with 2 CTs. Supports input types: Vrms, Irms, kW, kWh, kVA, kVAh, kVAR, kVARh, and PF.Features:• True RMS Power Measurements• Energy Analysis for 1P2W, 1P4W• Current Measurements Up to 200 A with
Different CT Ratio• Voltage Measurements Up to 300 V• Clip-on CT for Easy Installation• W Accuracy Better than 1% (PF=1)• Supports RS-485, Ethernet or CAN bus/CANopen
Interface• Supports Modbus RTU or Modbus TCP Protocol• Supports 2 Power Relay Output (Form A)• Supports PoE (IEEE 802.3af, Class 1)
Power Monitoring Technology | Maria Lemone | 1/9/15
Learn more
Clip on Current Transformers
Making Data Acquisition Easy
• Clip on Current Transformer• CT• For measuring Alternating
Electric Currents’• Connected to Power Meters
Power Monitoring Technology | Maria Lemone | 1/9/15
PM-2133
Making Data Acquisition Easy
3 Phase Compact Smart Meter/CT: O10 mm 60A/60 Hz communicable over Modbus RTU or CAN.
Supports Operating Temperatures between -10 to 70C.
Supports input types: Vrms, Irms, kW, kWh, kVA, kVAh, kVAR, kVARh, and PF.
Power Monitoring Technology | Maria Lemone | 1/9/15
Click here to learn more…
Home Automation
Making Data Acquisition Easy
PoE switch
PET-7018
Temp. sensor
Internet EthernetDIO, AIO
PDS Gateway
Power meter
Power Monitoring Technology | Maria Lemone | 1/9/15
Touchpad
Power Meter Data Loggers
Making Data Acquisition Easy
Power Meter Concentrator for logging and displaying power meter information. Comes with a 2 GB microSD card. Communicable over RS-232, RS-485, Ethernet and Modbus protocol.
Applications:• Display, monitoring, storage and
management of the power data• Power demand prediction and management• Power efficiency monitoring
PMC-5141
Power Monitoring Technology | Maria Lemone | 1/9/15
Click here to learn more…
PM-5141 Application
Making Data Acquisition Easy
Power Monitoring Technology | Maria Lemone | 1/9/15
PM-5151 Application
Making Data Acquisition Easy
Power Monitoring Technology | Maria Lemone | 1/9/15
Solar Monitoring Systems
Making Data Acquisition Easy
• Photovoltaic systems use solar panels to convert energy from sunlight into electricity.
• Allow for retrieval of status and data logging of solar panel energy applications.
Power Monitoring Technology | Maria Lemone | 1/9/15
Click here to read the whole application story
Local HMI’s for Displaying Power Data
Making Data Acquisition Easy
TPD-283
• Touchpad Compact Touch Screen PLC• High resolution 2.8" TFT color touch screen• Fits in regular electrical wall-mount outlets• Powered over Ethernet• Supports Modbus TCP• Comes with HMIWorks Ladder Logic and C language
programming and GUI development environment.• Designed for building and home automation• Excellent C/P ratio (cost/performance)• Operating temperature: -20 ~ 70°C (-4F ~ 158F)• Easily Integrates with I/O Modules
Power Monitoring Technology | Maria Lemone | 1/9/15
Click here to learn more…
Local HMI’s for Displaying Power Data
Making Data Acquisition Easy
TPD-430
• Touchpad Compact Touch Screen PLC
• High resolution 4.3" TFT color touch screen
• Powered over Ethernet• RS-485 and USB ports• Comes with HMIWorks
Ladder Logic and C language programming and GUI development environment.
• For building and home automation
• Excellent C/P ratio (cost/performance)
• Operating temperature: -20 ~ 70°C (-4F ~ 158F)
Power Monitoring Technology | Maria Lemone | 1/9/15
Learn more…
Energy Management Using SCADA Software
Making Data Acquisition Easy
Power Monitoring Technology | Maria Lemone | 1/9/15
Learn more..
Questions?
Making Data Acquisition Easy
• Please ask any questions you may have.
• Contact us:
Tel: +1 (310) 517-9888 +1 888-971-9888
Website: www.icpdas-usa.com
Email: [email protected]
Follow ICP DAS USA On:
Power Monitoring Technology | Maria Lemone | 1/9/15