power distribution & controls division sirius safety controls e-stops interlocks hinge switches...
TRANSCRIPT
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
SIRIUS Safety Controls
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
SIRIUS Safety Controls
SIRIUS E-STOP devices SIRIUS Interlock switchesSIRIUS Hinge switchesSIRIUS Cable Pull SwitchesSIRIUS Magnet SwitchesSIRIUS Two-Hand Controls
Popular designs for E-STOP circuits and machine guarding
Door guarding applications- Interlock with separate actuator- Interlock with Solenoid locking / unlocking- by non contact (Magnetic coded)
Two Hand Controls stations
SIRIUS Safety Control product range is applicable for applications Cat. 1 to Cat. 4 (EN954-1)
Safety Controls should always be used in conjunction with a Safety Relay or other safety rated modules such as ET200S / M / Eco distributed I/O or S7 Failsafe PLC’s
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
Class 52
NEMA 4X Corrosion Resistant
E-Stops
Class 52 4X Corrosion Resistant
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
Class 52 4X Corrosion Resistant
Epoxy coated devices for caustic and corrosive environments.
Self-protected against the ravages of industry’s harshest environments.
Heavy duty die cast parts shielded with epoxy coatings.
Perform reliably year-in and year-out under corrosive and caustic conditions.
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
3SB3 E-Stops 32mm 40mm 60mm
Project:
• E-Stop operator with 32 40 and 60 mm heads
• Plastic and metal versions
Status:
• Available in stock
32mm Metal= 3SB3500-1FA20
Plastic=3SB3000-1FA20
40mm Metal= 3SB3500-1HA20Plastic=3SB3000-1HA20
60mm Metal=3SB3500-1AA20Plastic=3SB3000-1AA20
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
New 3SB3 40MM E-Stop with Flat Head
This new e-stop has a flat mushroom head shape that many of our customers are familiar with and is similar to our push-pull operators. It is currently only available in plastic and it does carry the EN 418 rating
3SB3000-1XA20
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
Emergency Stop: Safety guaranteed
• High level of safety with emergency stop pilot devices
• Mechanical latching function acc. to EN 418
• Positive opening of NC elements
• Twist-to-release feature
• Also available with safety key lock
• Ergonomically shaped
• TÜV listed
SIGNUM 3SB3 AS-Interface (ASIsafe)
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
SIRIUS 3SE2 3SE3 Safety Limit and Interlock Switches
3SE2120 3SE2100 3SE2230 3SE2200 3SE224 3SE21203SE283SE37
Product Overview 3SE2 / 3SE3 Safety Limit and Interlock Switches
Safety Controls
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
SIRIUS Position Switches Suitable for Safety applications*
NC- contacts with direct opening action, acc. IEC 947-5-1
For use up to category 4 acc. EN954-1 when used with redundancy (i.e. two switches per door)
Economical, electronic compatible, electrically isolated moveable double contacts
High contact reliabillity even with low voltages and currents, e.g. 5V DC / 1mA
Ambient temperature from -35° to +85°C
High mechanical endurance, 30 million make-break operations
Actuator versions for all kinds of application
High degree of protection IP 67
Available in AS-Interface connection
Metal Versions
Metal Versions
Plastic Versions
Plastic Versions
* Only when direct opening contacts are used. See the symbol * Use of adjustable length and rod type actuators are not allowed in safety applications
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
Most Popular Interlock Switches
For use in door interlock (safety) circuits according to EN1088, up to cat. 4
Positive opening action contacts according to IEC 60947-5-1-3
Either 4 or 5 directions for actuator approach on most models
1 to 3 switching contacts
Standard, Lateral and radius actuators
Housing widths of 31, 40 and 52mm.
Metal or Plastic housings with IP65 / IP67
Some versions with M12 connector
Up to 30 Million mechanical switching operations
Ideal for use in hard-wired, ASIsafe or PROFIsafe distributed networks and SIMATIC F-PLC systems
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
SIRIUS Interlock Switches with Seperate Actuator
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
SIRIUS Interlock Switches with Seperate Actuator
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
• For use in safety circuits according to EN1088, up to cat. 4
• Safety door locking / unlocking on machine tools with speed monitors
• Solenoid locking or unlocking versions
• 270 / 450lbs locking force
• Either 4 or 5 directions of approach
• 2 or 4 switching contacts
• Standard, lateral and radius actuators
• Available with AS-Interface adaptors for connection to ASIsafe networks
Metal Enclosure3SE28
Plastic Enclosure3SE37
SIRIUS Interlock Switches with Seperate ActuatorSolenoid locking or unlocking
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
SIRIUS Interlock Switches with Seperate ActuatorSolenoid locking or unlocking
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
Actuator‘s for Solenoid locking or unlocking units
For 3SE283 / 84 versions
For 3SE375 / 76 and 3SE385 / 86 versions
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
SIRIUS Interlock Switches with Seperate ActuatorSolenoid locking or unlocking
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
Positive Mode Mounting for Interlock’s
no forced opening andeasy to circumvent
Closed Open
Incorrect Method
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
Closed Open
Correct Method
Actuator is forced open by theExternal force of the sliding doorActuator is forced open by the
External force of the sliding door
Positive Mode Mounting for Interlock’s
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
SIRIUS Safety Hinge Switches
Sleek low profile and
compact design
Used for perimeter protection
on guard doors
Tamper resistant
Positive opening action
Normally Closed contacts
IP65 and IP66 enclosures
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
SIRIUS Safety Hinge Switches
Advantages Mounting options:
- with integrated hinge - on hinge axis - on hinged flaps
Very small angles to switching point - 4o or 8o to open slow action contacts - 5° or 15o to open snap action contacts
Applications monitoring hinged doors up to category 4 acc. EN954-1
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
SIRIUS Hinge Switch Applications
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
• Plastic and metal enclosures
• Rope lengths up to 165’ with pretension
• Rope Lengths up to 400’ without pretension
• Two direction units with rope lengths of up to 165’ each direction (330’ total span)
• Can be used as a safety switch for conveyor systems or production lines, or as a signaling switch (without latching)
• Switches with 24VDC and 120VAC LED indicators
• Available with AS-Interface adaptors for connection to ASIsafe networks
SIRIUS 3SE7 Cable Pull Switches
New modelIntegrated E-StopCompetes againstAB Life Line 4
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
SIRIUS Rope-Pull Switch application
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
LifeLine 4 vs. 3SE7141
LifeLine 43SE7141
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
Safety Magnet Switches
Advantages: System comprising of a magnet and
switching element 3 different versions, IP67 rated AC or DC voltage Ideal for connection to safety networks and
Safety PLC‘s Single channel or Six channel evaluation
units for cat. 3 or cat. 4 applications
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
Safety Magnet Switches
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
New Multi-Magnetic Switch Relay3SE6806-2CD00
Up to 6 sensors can be connected 24V DC operating voltage For 1NC/1NO magnetic switch types 6 PLC signal outputs, each 20 mA for
individual door annunciation 2 enabling circuits, relay output Cat. 3 according to EN 954-1 UL / CSA approval
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
Safety Magnet Switches 3SE6Switching Ranges
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
Safety Magnet Switches 3SE6 Application as door switch
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
Two Hand Control Systems
Compliant with DIN 24980 (EN 574) Console is rated at IP65 Applicable to Category 4 according to EN 954-1 4 or 8 control devices can be additionally mounted at the center of the operation
console Plastic or die-cast aluminum housingConsole mounting on stand or directly at the machine
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
Two Hand Control SystemsConnection possibilities
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
Two Hand Control Systems
Two Hand control systems, when used as the primary means of personnel safeguarding shall:
Be designed to prevent accidental or unintentional operation
Have the individual operator’s hand controls arranged such that both hands must be used, and both circuits must be activated within 500ms to initiate / cycle the machine.
Requires individual hand controllers for each operator when multiple operators exist
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
ASIsafe and Profisafe Safety Networks
Safety on a bus network saves overall costs!!
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
ASIsafe and Profisafe Safety Networks
Safety networks provide savings at OEM’s and End Users: Considerable wiring reduction Labor savings Increased diagnostics of safety components Simpler maintenance Increase machine availability Higher production output
SIRIUS Safety Controls are ideal for: Connection to safety networks Pull through on your automation sale
SIMPLIFIED SAFETY
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
AS-Interface Distributed Configuration Safety at Work
Standard PLC andstandard master
Safety monitor Safe emergency stop button
AS-ipower unit
Safe position switch
Safe light barrier
Safe light grid
Standard module
Safe module
Standardmodule
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
AS-Interface Distributed Configuration Safety at Work
Standard PLC andstandard master
Safety monitor Safe emergency stop button
AS-ipower unit
Safe position switch
Safe light barrier
Safe light grid
Standard module
Safe module
Standardmodule
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
AS-Interface Distributed Configuration Safety at Work
Gateway toAS-Interface
Safety monitor Safe emergency stop button
AS-ipower unit
Safe position switch
Safe light barrier
Safe light grid
Standard module
Safe module
Standardmodule
Power Distribution & Controls Division
SIRIUS
Safety Controls
E-Stops
Interlocks
Hinge Switches
Cable Pulls
Safety Magnets
Two Hand Controls
Safety Network Controls
Siemens Energy & Automation 2005
Safety Controls for Safety Networks (ASIsafe)
Rope Pull Switches
Refer to the Controls Catalog or the IKPI Catalogfor additional units or contact product marketing for the latest offering
Interlock Switches
Limit Switches E-Stop Switches