polytechnic hong kong - knx- · pdf file•knx/bacnet mapping: as annex h1 to the iso...
TRANSCRIPT
www.knx.org
International Standardization of
Home and Building Automation
Joost Demarest - KNX Association
<Joost Demarest>
< KNX Association cvbar>
Page No. 2
October 12 KNX: The worldwide STANDARD for Home & Building Control
General Standardization overview
NC
CENELEC CEN ETSI
CP
NC= national mirror commitees
CP = companies
JTC1
Telecommunication Electrotechnical Other areas
IT
<Joost Demarest>
< KNX Association cvbar>
Page No. 3
October 12 KNX: The worldwide STANDARD for Home & Building Control
European Standardization (1)
• CENELEC (1)
• European Committee for Electro-technical Standardization
• Responsible committee = Technical Committee (TC) 205
• Scope: Home and Building Electronic Systems
• Standard series for home and building control = EN 50090
• KNX Association • Cooperating Partner to CENELEC = important player in the field of
home and building control
• Possibility to submit standardization proposals without need for New Work Item proposal by national committees
• Before 2003: EN 50090-2-2 • Only existing part of EN 50090 series documenting hardware
requirements
• EMC, Electrical Safety, Environmental conditions
• System independent
<Joost Demarest>
< KNX Association cvbar>
Page No. 4
October 12 KNX: The worldwide STANDARD for Home & Building Control
European Standardization (2)
• CENELEC (2)
• Since 2003: • approval of European TC 205 national mirror committees of
• KNX media (TP, PL, RF)
• KNX protocol (LL, NL, TL, A(I)L)
• Management procedures
• KNX Interworking model and KNX standardized data types
• All part of the EN 50090 series
• Since 2010: • Out-phasing of EN 50090-2-2
• Replacing by new standard series EN 50491
• EN 50090 becomes fully KNX – EN 50491 collects hardware requirements for any HBES solution, even systems that are not EN 50090 compliant
<Joost Demarest>
< KNX Association cvbar>
Page No. 5
October 12 KNX: The worldwide STANDARD for Home & Building Control
EN 50090: current status
EN 50090-5-3
RF
EN 50090-2
System overview
EN 50090-3
Aspects of application
EN 50090-5
Media dependent
EN 50090-6
Interfaces
EN 50090-7
System Management
EN 50090-9
Installation requirem.
EN 50090-1
Standard struct.
EN 50090-2-1
System architect.
EN 50090-3-1
Introduction
EN 50090-2-2
General techn
requirements
EN 50090-9-1
Class 1, Cabling TP
Architecture and
hardware
requirements
Communication
Application
Installation
EN 50090-4-1 Application layer
TR 50552 - Media
interface Class 1, TP
EN 50090-7-1 Mgmt procedures
EN 50090-1
Standard structure
EN 50090-5-2 Class 1, Twisted Pair
EN 50090-4
Media independent
EN 50090-4-2
Media independent
layers
EN 50090-2-3
Functional safety normal”
EN 50090-5-1
Power line
EN 50090-3-2
User process
prA1 prA2
EN 50090-3-3
Interworking
EN 50590-4-3
Communication
over IP
replaced by EN 50491-3 and -5 To be withdrawn
replaced by EN 50491-4 –to be withdrawn
transfer to EN 50491-6-1 –under UAP
<Joost Demarest>
< KNX Association cvbar>
Page No. 6
October 12 KNX: The worldwide STANDARD for Home & Building Control
EN 50491: current status
Available
Electrical Safety Requirements
-10 : Interworking, -11 Gateways, -12 Security, …
5-1 Requirements, conditions and test setups
5-2 Requirements for systems used in residential, commercial and
light industry
5-4 Requirements for industrial environment
Part 6-3 Assessment of HBES/BACS installations
Structure and usage of the standard
Functional safety requirements : 4-1 General
6-2 Inspection and Testing of HBES/BACS Installation
EN 50491-10, -11, -12
Functional requirements
EN 50491-4
Functional Safety
EN 50491-5
EMC
EN 50491-6
Installation
EN 50491-2
Environmental conditions
EN 50491-3 Electrical
Safety Requirements
EN 50491-1 Overview and
General Requirements
……..
Functional safety requirements: 4-2 Safety Related Equipment
Environmental Conditions and Requirements
Foreseen
6-1 Installation requirements
<Joost Demarest>
< KNX Association cvbar>
Page No. 7
October 12 KNX: The worldwide STANDARD for Home & Building Control
European Standardization (3)
• CEN
• European Committee for Standardization
• Responsible committee = Technical Committee (TC) 247
• Scope: Building Automation Control Systems
• Currently standardised systems • LON: EN 14908 series
• BACnet: ISO 16484 series (see worldwide ISO standardization)
• KNX
• Extend of KNX standardization • EN 13321-1
• EN 50090 series referenced as standard also for BACS
• EN 13321-2
• KNXnet/IP tunnelling and routing protocol
• Transmission of KNX frame encapsulated in IP frame
• Part in turn referenced in the EN 50090 series
• EN15232
• System independent standard documenting impact of use of BACS on energy efficiency of buildings
• As KNX = BACS standardized system, indirectly KNX = solution to fulfil EN 15232 standard
<Joost Demarest>
< KNX Association cvbar>
Page No. 8
October 12 KNX: The worldwide STANDARD for Home & Building Control
Worldwide Standardization (1)
• ISO/IEC JTC1
• Joint Technical Committee of International Standardization Organisation and International Electro-Technical Commission
• Responsible committee = SC 25
• Scope: Home Electronic Systems
• Standard series: ISO/IEC 14543
• Currently standardised systems • Part 3: KNX
• Part 4: Echonet (Japan)
• Part 5: IGRS (China)
• Extend of KNX standardization • KNX media (TP, PL, RF)
• KNX protocol (LL, NL, TL, A(I)L)
• Management procedures
<Joost Demarest>
< KNX Association cvbar>
Page No. 9
October 12 KNX: The worldwide STANDARD for Home & Building Control
Worldwide Standardization (2)
• ISO TC 205
• Counterpart of European standardization body TC247 at worldwide level
• Scope: Building Automation Control Systems
• Standard series: ISO 16484 series
• Currently standardised systems • Only BACnet: standardization input either
• Via Dresden Agreement: input from TC247
• Through ANSI/ASHRAE
• American National Standardization Institute - American Society of Heating, Refrigerating and Air-Conditioning Engineers
• via its standard 135
• KNX/BACnet Mapping: as Annex H1 to the ISO 16484-5
<Joost Demarest>
< KNX Association cvbar>
Page No. 10
October 12 KNX: The worldwide STANDARD for Home & Building Control
Other standardization (1)
• P.R. China
• Translation initiated in 2005 of ISO/IEC 14543-3
• Chinese pre-standardization achieved in 2007 as GB/Z 20965
• Establishment of KNX accredited test lab for lower layer stack testing and interoperability in November 2011
• Change to GB/T Status expected beginning 2013
• GB/T standard will also include translation of KNXnet/IP specifications
• CEN TC 294
• European Committee for standardisation of battery operated meters
• KNX RF and M-Bus (as part of EN 13757-4) share the same Physical medium (S-Mode)
• KNX has liaison status at CEN TC294
<Joost Demarest>
< KNX Association cvbar>
Page No. 11
October 12 KNX: The worldwide STANDARD for Home & Building Control
Other standardization (2)
• Smart Metering TR 50572
• reference architecture for smart meter infrastructure
• Result of M441 mandate from Commission
• EN 50090 series referenced as solution for interface between smart meter and home
• Smart Grid IEC TC57
• Scope: Power systems control equipment and Energy management systems
• New WG21 set up – use cases and interfaces between a.o. smart grid and industrial, home and building automation
• Liaison request of KNX Association recently granted
<Joost Demarest>
< KNX Association cvbar>
Page No. 12
October 12 KNX: The worldwide STANDARD for Home & Building Control
Standardisatie
EN50491
Alleen hardware requirements, geen protocol
Geen storingen, geen veiligheidsproblemen
EN15232
EN50090 is een protocolserie die toelaat te
voldoen aan EN15232: energiesparen
<Joost Demarest>
< KNX Association cvbar>
Page No. 13
October 12 KNX: The worldwide STANDARD for Home & Building Control
Standardisatie
EN50090: één protocol Eenvoudiger, goedkopere en verdere integratie van
toepassingen: verdere automatisatie en besparing,
verdere comfortverhoging
Aanvangsfase
Vermijd duurderde, langere integratie van incompatibele
systemen.
Onderhoud, evolutie, uitbreiding
Stabiliteit: betere garantie van flexibilitiet naar de toekomst
Interworking: uitzonderlijk hoog niveau van
samenwerking produkten van verschillende fabrikanten
KNX: één enkel tool
www.knx.org
Thank you for your attention!
For more information
Joost Demarest – KNX Association cvba
Tel: +32 2 775 86 44
E-Mail: [email protected]