PHOTOMETRICSCombine soft lighting and water resilient properties of Polaris series luminaries, to expand your lighting designs.
POLARISAFL 80W & 100W
POLARISAFL 200W
POLARISAFL 300W & 400W
POLARISAFL 500W & 600W
POLARISAFL 800W & 1000W
REVIT & IES FILESAVAILABLE AT
WWW.SPECGRADELED.COM
w
POLARIS: AFL FLOOD LED
PHOTOMETRICS
EASY ACCESS DRIVER HOUSING
POLARIS: AFL FLOOD
TEMPERED GLASS
ADJUSTABLE TRUNION
EXPECTED LIFEOVER 100,000 HRS.
AVAILABLE FROM 80W
UP TO 1000WSIX OPTICS
Advanced LED technology and proprietary optics that distribute the
light to the target area in a prescribed manner. This creates sites with
incredible uniformity and visual comfort while requiring fewer lumens
NATATORIUM RATED CONSTRUCTION
Corrosive resistant powder coated finish
Stainless steel hardware
Chlorine resistant treated gasket1 5° x 1 5°
3 0° x 30°40° x 40°6 0° x 6 0°
6 0° x 1 35° 85° x 1 35°
PATENTED THERMAL MANAGEMENT The proprietary patented thermal management
design, ensures low LED junction temperature
while maintaining its extremely light weight.
It has become the go-to series of engineers and
specifiers for exterior and interior use
200W 347-480V OPTIONALwith external step-down
transformerPOLARIS: AFL 300W, 400W,
500W, 600W, 800W & 1000W (Step-down
transformer-as shown)
IES ROAD REPORT AFL-100-15X15POLAR GRAPH
Maximum Candela = 56578.578 Located At Horizontal Angle = 0, Vertical Angle = 2.5# 1 - Vertical Plane Through Horizontal Angles (0 - 180) (Through Max. Cd.)# 2 - Horizontal Cone Through Vertical Angle (2.5) (Through Max. Cd.)
Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.Calculations based on published IES Methods and recommendations, values rounded for display purposes.Results derived from content of manufacturers photometric file.
Page 1
14145
28289
42434
56579
2
1
IES ROAD REPORT AFL-100-30X30POLAR GRAPH
Maximum Candela = 28673.1 Located At Horizontal Angle = 0, Vertical Angle = 0# 1 - Vertical Plane Through Horizontal Angles (0 - 180) (Through Max. Cd.)# 2 - Horizontal Cone Through Vertical Angle (0) (Through Max. Cd.)
Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.Calculations based on published IES Methods and recommendations, values rounded for display purposes.Results derived from content of manufacturers photometric file.
Page 1
7168
14337
21505
28673
2
1
IES ROAD REPORT AFL-100-40X40POLAR GRAPH
Maximum Candela = 21671.5 Located At Horizontal Angle = 60, Vertical Angle = .9# 1 - Vertical Plane Through Horizontal Angles (60 - 240) (Through Max. Cd.)# 2 - Horizontal Cone Through Vertical Angle (.9) (Through Max. Cd.)
Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.Calculations based on published IES Methods and recommendations, values rounded for display purposes.Results derived from content of manufacturers photometric file.
Page 1
5418
10836
16254
21672
2
1
IES ROAD REPORT AFL-100-60X60POLAR GRAPH
Maximum Candela = 14701 Located At Horizontal Angle = 200, Vertical Angle = .9# 1 - Vertical Plane Through Horizontal Angles (200 - 20) (Through Max. Cd.)# 2 - Horizontal Cone Through Vertical Angle (.9) (Through Max. Cd.)
Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.Calculations based on published IES Methods and recommendations, values rounded for display purposes.Results derived from content of manufacturers photometric file.
Page 1
3675
7351
11026
14701
2
1
IES ROAD REPORT AFL-100-60X135POLAR GRAPH
2581
5161
7742
10323
1
2
Maximum Candela = 10322.5 Located At Horizontal Angle = 0, Vertical Angle = 62.1# 1 - Vertical Plane Through Horizontal Angles (0 - 180) (Through Max. Cd.)# 2 - Horizontal Cone Through Vertical Angle (62.1) (Through Max. Cd.)
Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.Calculations based on published IES Methods and recommendations, values rounded for display purposes.Results derived from content of manufacturers photometric file.
Page 1
IES ROAD REPORT AFL-100-85X135POLAR GRAPH
1997
3995
5992
7990
1
2
Maximum Candela = 7989.7 Located At Horizontal Angle = 340, Vertical Angle = 58.5# 1 - Vertical Plane Through Horizontal Angles (340 - 160) (Through Max. Cd.)# 2 - Horizontal Cone Through Vertical Angle (58.5) (Through Max. Cd.)
Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.Calculations based on published IES Methods and recommendations, values rounded for display purposes.Results derived from content of manufacturers photometric file.
Page 1
1 5º x 15º 30º x 30º 40º x 40º 60º x 60º 60º x 135º 85º x 135º
LUMINAIRE RATED IP 65LIGHT ENGINE RATED IP66
REVIT & IES FILESAVAILABLE AT
WWW.SPECGRADELED.COM
TOLL-FREE: 888-410-5337 | FAX: 614-868-5344 | © 201 6 SpecGradeLED
MISC SPECS Dimmable: 0-10V (optional)
Occupancy sensor: (optional)
Hanging weight: 18 lbs.
Natatorium Rated (optional)
MATERIALSHousings: Die cast aluminum
Heat sink: Double folded aluminum fins
Lens: Tempered glass
LED chip: Lumileds Luxeon-T
Driver: UL approved Philips
Gasket: Neoprene
POLARIS FLOODAFL 200WREPLACES UP TO A 500-WATT METAL HALIDE FIXTURES
SPECIFICATIONSExpected life: over 100,000 hrs.
Rating: IP 65
Color Rendering Index (CRI): >80
Operating temp: -22°F–122°F
Operating temp: -3 1–165°F (opt)
Power factor: >0.95%
Input line voltage: 120-277 VAC
480V available (external step down transformer)
Input line frequency: 50/60 Hz
LED efficiency: - warm white, 91 lm/w - natural white, 104 lm/w - cool white, 1 14 lm/w
DIMENSIONS
20”
STANDARD YOKE MOUNTING WITH ADJUSTABLE PIVOT LIMITS
Standard Yoke Mounting Adjustable Pivot Limits
OPTIONAL: TILTMOUNTING BRACKET
8
14”
PHOTOCELLS
347-480V(OPTIONAL)
POLARIS: AFL OPTIONAL EQUIPMENT
200W EPA SPECS
Fixture Wind Direction (ft2)ANGLE FRONT SIDE
90˚ FROM HORIZ: 1.9 ft2 0.3 ft2
45˚ FROM HORIZ: 1 .2 ft2 0.2 ft2
0˚ FROM HORIZ: 0.3 ft2 0.3 ft2
OS: Occupancy sensor for wet location (IP65)
GLARE SHIELD (GS)CTAX-1: 80W, 100W, 200W Slipfitter for 2-3/8” tenon size
APC-1: 1 10-130V
APC-2: 208-277V
www.SpecGradeLED.comTOLL-FREE: 888-410-5337 | FAX: 614-868-5344 | © 201 6 SpecGradeLED
POLARIS: AFL 200W FLOOD
COLOR TEMPERATURES/DELIVERED LUMENS
SERIES WATTS SYSTEMWATTAGE
SYSTEMPOWER [W] BEAM INPUT VOLT. WW
3500KNW
4000KCW
5000KCW
6000KFINISH OPTIONS/ACCESSORIES
AFL 200W 220W 220W 15°x 15° 90-305V 18130 lm 20914 lm 22015 lm 22900 lm BL BLACK CTAX-1 SLIPFITTER
30°x30° 347-480V (OPT.)
STEPDOWN EXTERNAL
TRANSFORMER
WT WHITE OS OCCUPANCY SENSOR
40°x40° RAL OTHER COLORSAVAIL.W/RAL#(OPT)
APC -1 ADJ. PHOTO CELL 1 10-130V
60°x60° APC -2 ADJ. PHOTO CELL 208-277V
60°x 135° SP10 SURGE PROTECTOR: 10KA
85°x 135° SP20 SURGE PROTECTOR: 20KA
NAT NATATORIUM FINISHRATED (OPT.)
TL TILT MOUNT
GS GLARE SHIELD
DIM DIMMABLE
FL FROSTED LENS
HTD HIGH TEMP DRIVER
WW = WARM WHITE NW = NATURAL WHITE CW = COOL WHITE REVIT & IES FILES are located at www.SpecGradeLED.com
PRODUCT CERTIFICATIONS, WARRANTIES & APPROVALS
PRODUCT SPECIFICATIONS
LM79 LM805YEARDRIVER
WARRANTY10YEAR
LED
WARRANTYPRODUCT INSURANCE
RECALL DIMMABLE0-10V
REVIT(BIM)Files availableIP65 IP66
DUE TO CONTINUOUS IMPROVEMENT AND INNOVATION, PRODUCT APPEARANCE AND SPECIFICATIONS MAY CHANGE WITHOUT NOTICE. ACTUAL PERFORMANCE MAY DIFFER AS A RESULT OF END-USER ENVIRONMENT AND APPLICATION.