LEMO FLUIDIC / PNEUMATICCONNECTORS WITH VALVE
FOR B AND K SERIES
PLUS ADDENDUM FOR
FLUIDIC / PNEUMATIC
WITHOUT VALVE
1www.lemo.com
® ®
1www.lemo.com
® ®
Table of Contents
Material and Treatment ........................................................................................................Inside cover
Precision Modular Connections .............................................................................................................2
P1 & P3 Fluidic / Pneumatic with shutoff valves ..................................................................................3
European Recommended Tubing/Hose.................................................................................................3
2B & 5B Series..........................................................................................................................................5
Part Numbering Example...................................................................................................................6
2K & 5K Series..........................................................................................................................................7
Part Numbering Example...................................................................................................................8
Fluidic insert configurations for B & K series..................................................................................9-10
Collets for B & K Series ...................................................................................................................11-12
Addendum: Fluidic / Pneumatic Without Valve .............................................................................15-19
LEMO Fluidic / Pneumatic ConnectorsThis catalog gives an overview of monofluidic and hybrid mixed electrical and fluidic / pneumatic connectors. The modularpieces and Swiss precision manufacturing program gives a diverse and wide range of options and configurations. The foun-dation LEMO B series (indoor IP50 applications) and LEMO K series (outdoor IP68 applications) give a wide range of plugand receptacle housing configurations. Sizes range from the small size 00 monofluidic to size 5 in both the B and K series.
2www.lemo.com
® ®
Precision modular connectors to suit your applicationSince it’s creation in Switzerland in 1946 the LEMO Group has been recognized as a global leader of circular Push-Pull connectors and connector solutions. Today LEMO and its affiliated companies, REDEL and COELVER, are active in morethan 80 countries with the help of over 40 subsidiaries and distributors.
Over 50’000 connectorsThe modular design of the LEMO range provides over 50’000 connectors from miniature ø 3 mm to ø 50 mm, capable of handling cable diameters up to 30 mm and for up to 106 contacts.
This vast portfolio enables you to select the ideal connector configuration to suit almost any specific requirement in most markets, including medical devices, test and measurement instruments, machinery, audio video broadcast, telecommuni-cations and military.
LEMO’s Push-Pull Self-Latching Connection System
The LEMO self-latching system allows the connectorto be mated by simply pushing the plug axially into the receptacle.
This self-latching system is renowned worldwide for its easy and quick mating and unmating features. It provides absolute security against vibration, shock or pull on the cable, and facilitates operation in a very limited space.
®UL RecognitionLEMO connectors are recognized by the Underwriters Laboratories (UL). The approval of the complete system (LEMOconnector, cable and your equipment) will be easier because LEMO connectors are approved.
CE markingCE marking means that the appliance or equipment bearing it complies with the protection requirements of one orseveral European safety directives. CE marking applies to complete products or equipment, but not to electro-mechanical components, such as connectors.
RoHSLEMO connectors are in compliance with the RoHS directives (2002/95/EC) of the European Parliament. This directivespecifies the restrictions of the use of hazardous substances in electrical and electronic equipment marketed in Europe.LEMO guarantees that its connectors are free of mercury, cadmium, lead, hexavalent chromium and polybromide biphenyl(PBB) or polybromide diphenyl ether (PBDE).
Once firmly latched, connection cannot be broken bypulling on the cable or any other component partother than the outer release sleeve.
When required, the connector is disengaged by a sin-gle axial pull on the outer release sleeve. This firstdisengages the latches and then withdraws the plugfrom the receptacle.
tube supportspringclipmale sleevemale shutoffo-ring
Male contact
flow
Female contact
tube supportspringfemale sleeveo-ringclipfemale shutoffo-ring
1
3
4
1
3
2
4
5
6
76
5
2
6 3 1544321 65 7 2
Part Section Showing Internal Components
The P1 fluidic contact is designed to fit multi fluid connectors or mixed fluid/electrical connectors from 2B to 5B and 2Kto 5K series. This new design includes a shut-off valve. It fits into all insert cavities that already accept the LEMO coax-ial type «C» of contact. The P3 fluidic contact is designed to fit multi fluid connectors of the 5B and 5K series.Its main features are:– contacts with shut-off valve– maximum working pressure 6 bars– stainless alloy body– after mounting on tube, the contact is installed in the main insulator and retained with a metallic clip.The contact is fitted with FPM o-ring, it can be used with liquids or gas.
Technical CharacteristicsMaterial and Treatment Mechanical and Environmental
1000 cycles P1/P3 IEC 60512-5 test 9a-20°C, +125°C P1/P36 bars P1/P350 l/min P10.80 l/min P1210 l/min P34.20 l/min P3
Mating durabilityTemperature rangeMax. working pressureAir flow rate at 6 barsWater flow rate at 6 barsAir flow rate at 6 barsWater flow rate at 6 bars
Value StandardCont.typeCharacteristics
Stainless steelAlloy CuNiZnStainless steelCuBeFPM
BodyValveSpringClipsO-ring
ValueComponents
P1/P3 Fluidic contact with valve
Flow/pressure diagram P1 contact type
Flow rate AIRl/min
Pressure
(bars)
20
10
021 3 4 5 6
40
50
30
Flow rate WATERl/min
Pressure
(bars)
0.4
0.2
021 3 4 5 6
0.8
1.0
0.6
Note: test carried out with a 2 mm inner diameter tube.
Flow/pressure diagram P3 contact type
Flow rate AIRl/min
Pressure
(bars)
100
50
021 3 4 65
200
150
Flow rate WATERl/min
Pressure
(bars)
1.7
0.721 3 4 5 6
3.7
4.7
2.7
Note: flow direction is always from female contact to male contact.
3www.lemo.com
® ®
4www.lemo.com
® ®
2B, 3B, 2K, 3K2B, 3B, 2K, 3K2B, 3B, 4B, 5B2K, 3K, 4K, 5K
Diameter (mm)Outer ø Inner ø
Series
4.0 2.04.0 2.03.0 1.83.0 1.8
P1
Contacttype
Recommended tubing/hose
Supplier Material Color Working temperature
Legris 1100P0400 Polyamide (nylon) White -20° C to 80° CLegris 1100P0401 Polyamide (nylon) Black -20° C to 80° CLegris 1025U030118 Polyurethane Black -20° C to 70° CLegris 1025U030118 Polyurethane Black -20° C to 70° C
5B, 5K 6.0 4.0P3 Legris 1100P0601 Polyamide (nylon) Black -20° C to 80° C
Known European hoses for P1 & P3 contacts
Straight plugs
FGG
FNG*
FGG*
FGG*
FGY*
FGY*
Plastic housing modelsFixed receptaclesStraight plugs
ENG*
ENY*
Free receptacles
PHG
PHG*
Fixed receptacles
PKG*
PFG* ECG*
Fixed receptacles
EGG
EHG*
Model DescriptionECG Fixed receptacle, with two nuts, key (G)
or keys (A…L and R), (back panel mounting)
EGG Fixed receptacle, nut fixing, key (G) or keys (A…L and R)
EHG Fixed receptacle, nut fixing, key (G) or keys (A…L and R) with visible shell
ENG Fixed receptacle with grounding tab, nut fixing, key (G or J), PEEK outer shell
ENY Fixed receptacle with grounding tab, nutfixing, keys (Y), PSU or PPSU outer shell
FGG Straight plug, key (G) or keys (A…L and R) and cable collet
FGG Straight plug, key (G) or keys (A…L)cable collet and nut for fitting a bendrelief
FGG Straight plug, key (G or J), cable collet, PEEK outer shell
FGY Straight plug, keys (Y), cable collet and PSU or PPSU outer shell
FGY Straight plug, keys (Y), cable collet and PSU or PPSU outer shell and nut for fitting a bend relief
FNG Straight plug, key (G) or keys (A…L and R) and cable collet with lanyard release
PFG Fixed receptacle, with two nuts, key (G) or keys (A…L and R) and cable collet (back panel mounting)
PHG Free receptacle, key (G) or keys (A…L and R) and cable collet
PHG Free receptacle, key (G) or keys (A…L) and cable collet and nut for fitting a bend relief
PKG Fixed receptacle, nut fixing, key (G) or keys (A…L and R) and cable collet
The P1 fluidic contact has been designed to work in the 2B to 5B series. The P3 contact has been designed to work inthe 5B series. The main features of these series are as follows:– security of the LEMO Push-Pull self-latching system– the alignment key (G, A…L, Y and R) ensures excellent repeatability of performance during frequent matings– the P1 fluid contact allows hybrid configuration in the 2B series and multi fluid up to 10 channels in the 5B series.The possible outer cable diameters range from 4.0 to 25 mm.
Certain models and certain alignment key may not be available in all series. Please consult us.
2B-5B Series
* Not show in this catalog.Refer to our catalog unipole-multipole
5www.lemo.com
® ®
6www.lemo.com
® ®
FGG.2B.P12.CLAD72Z = Straight plug with key (G), 2B series, mixed type to accept one P1 fluid contact and 4 low voltage electrical contacts, chrome-plated brass housing, PEEK insulator, 4 male solder electrical contacts, type D collet system to suit a 6.1 to 7.0 mm diameter cable, and a nut for fitting a bend relief.
FGG 2B
Housing: (page 9)C = chrome-plated brassP = polysulfone
Cable ø: (page 10)
Collet type: (page 10)
LV contact type: (page 9)
Variant: see note 1)P12
Series: (see examples below)
Model: (see examples below)
ZC L A D 72
Type: (page 8)
Insulator: L = PEEK
Part Number Example
Straight plug, key (G) or keys (A…L and R) and cable collet
Reference
Model Series
Dimensions (mm)
A L M S1 S2
FGG 2BFGG 3BFGG 4BFGG 5B
15 50 38 13 1218 58 43 15 1425 75 57 21 2035 103 78 31 30
S 2
~M
~L
S 1
ø A
FGG
Free receptacle, key (G) or keys (A…L and R) and cable collet
Reference
Model Series
Dimensions (mm)
A L S1 S2
PHG 2BPHG 3BPHG 4BPHG 5B
16.5 47.0 13 1219.0 56.0 15 1424.4 73.0 21 2034.2 99.0 31 30
S 2
~L
S 1
ø A
PHG
Fixed receptacle, nut fixing, key (G) or keys (A…L and R)
ø Ae
ø B
S 3
S 1
M
E max
L max
Dimensions (mm)
A B e E L M S1 S3
18 19.2 M15x1.0 8.5 28.8 1.8 13.5 1722 25.0 M18x1.0 11.5 30.0 2.0 16.5 2228 34.0 M25x1.0 12.0 34.5 2.5 23.5 3040 40.0 M35x1.0 11.0 36.5 3.0 33.5 –40 40.0 M35x1.0 11.0 45.9 3.0 33.5 –
Reference
Model Series
EGG 2BEGG 3BEGG 4BEGG 5BEGG 5B1)
EGG
Note: Connectors are always delivered with fluidic contact.1) The «Variant» position in the reference is used to indicate the presence of a collet nut for fitting the bend relief. The bend relief must be ordered separately (see page 13).
Note: 1) with P3 contact.
Free receptacles
Fixed receptacles
PKG*
PEG*
PHG*
Fixed receptacles
EGG
EEG*
EBG*
Straight plugs
Fixed plug
FGG*
PHGFGG
FXG*
Model DescriptionEBG Fixed receptacle with square flange,
key (G) or keys (A…F, L and R), four holes fixing
EEG Fixed receptacle, nut fixing, key (G) or keys (A…F, L and R) (back panel mounting)
EGG Fixed receptacle, nut fixing, key (G) or keys (A…F, L and R)
FGG Straight plug, key (G) or keys (A…F, L and R), cable collet
FGG Straight plug, key (G) or keys (A…F, L and R), cable collet and nut for fitting a bend relief
FXG Fixed plug with round flange, four holes fix-ing, key (G) or keys (A…F, L and R)
PEG Fixed receptacle, nut fixing, key (G) or keys(A…F, L and R), cable collet and nut for fitting a bend relief (back panel mounting)
PHG Free receptacle, key (G) or keys (A…F, L and R), cable collet
PHG Free receptacle, key (G) or keys (A…F, L and R), cable collet and nut for fitting a bend relief
PKG Fixed receptacle, nut fixing, key (G) or keys(A…F, L and R), cable collet and nut for fitting a bend relief
* Not show in this catalog.Refer to our catalog unipole-multipole
The P1 fluidic contact has been designed to work in the 2K-5K series. The P3 contact has been designed to work in the5K series. The main features of these series are as follows:– security of the LEMO Push-Pull self-latching system– specially designed for outdoors applications. All these models are waterproof when mated and reach a protection
index of IP 66-IP 68, according to the IEC 60529 standard– the alignment key (G, A…F, L and R) ensures excellent repeatability of performance during frequent matings– the P1 fluidic contact allows hybrid configuration in the 2K series and multi fluid up to 10 channels in the 5K series.The 2K-5K series consists of ten models which will accept outer cable diameters ranging from 2.6 mm to 23.5 mm.
Certain models and certain alignment key may not be available in all series. Please consult us.
2K-5K Series
7www.lemo.com
® ®
8www.lemo.com
® ®
FGG.3K.P20.CLZC76Z = Straight plug with key (G), 3K series, multi fluid with 2 times P1 contacts, chrome-plated brasshousing, PEEK insulator, C type collet for 7.5 mm diameter cable, and nut for fitting a bend relief.
FGG 3K
Housing: C = chrome-plated brass
Cable ø: (page 10)
Cable fixing type:T = cable adapter
LV Contact Type: (page 9)
Variant: see note 1)P20
Series: (see examples below)
Model: (see examples below)
C L Z C 76 Z
Type: (page 8)
Insulator: L = PEEK
Part Number Example
S 2
M max
L max
¿ A
Straight plug, key (G) or keys (A…F, L and R),cable collet and nut for fitting a bend relief
Reference
Model Series
Dimensions (mm)
A L M S2
FGG 2KFGG 3KFGG 4KFGG 5K
16 101 85.0 1219 109 89.0 1525 131 110.5 1938 160 135.0 30
FGG
Note: The overall length dimension is with Desmopan bend relief
L max
ø A
S 2
Free receptacle, key (G) or keys (A…F, L andR), cable collet and nut for fitting a bend relief
Reference
Model Series
PHG 2KPHG 3KPHG 4KPHG 5K
Dimensions (mm)
A L S2
19 103.0 1223 113.0 1529 135.5 1942 164.0 30
PHG
Note: The overall length dimension is with Desmopan bend relief
Fixed receptacle, nut fixing, key (G) or keys (A…F, L and R)
Reference
Model Series
EGG 2KEGG 3KEGG 4KEGG 5K
¿ Ae¿ B
S 3
S 1
M
E max
L max
EGG
Dimensions (mm)
A B e E L M S1 S3
25 27.0 M20x1.0 9 32.8 5.0 18.5 2431 34.0 M24x1.0 11 35.5 6.0 22.5 3037 40.5 M30x1.0 9 37.0 6.5 28.5 3655 54.0 M45x1.5 10 40.5 9.0 42.5 –
Note: Connectors are always delivered with fluidic contact.1) The «Variant» position in the reference is used to indicate the presence of a collet nut for fitting the bend relief. The bend relief must be ordered separately (see page 13).
9www.lemo.com
® ®
2 P1 6 – – – – – – – – –
2 P1 6 4 0.9 l l 1.20 1.05 1.00 0.80 8.0
2 P1 6 6 0.9 l l 1.20 1.05 1.00 0.80 8.0
2 P1 6 10 0.7 l l 0.95 0.75 0.85 0.65 6.0
2 P1 6 16 0.7 l l 0.80 0.70 0.80 0.75 5.5
1 P1 6 2 0.9 l l 1.75 1.60 1.85 1.60 9.0
1 P1 6 4 0.7 l l 0.85 1.20 0.85 1.25 6.0
1 P1 6 6 0.7 l l 0.85 1.20 0.85 1.25 6.0
1 P1 6 10 0.7 l l 1.15 1.35 1.30 1.05 6.0
Nb
of fl
uidi
c tu
be
Type
Ext
. ø o
f tub
e
Int.
ø of
tub
e
Max
. wor
king
pre
ssur
e (b
ars)
Con
tact
No
ø A
(mm
)
Sol
der
Crim
p
Test
vol
tage
(kV
rm
s)C
onta
ct-c
onta
ctTe
st v
olta
ge (k
V r
ms)
Con
tact
-she
llTe
st v
olta
ge (k
V r
ms)
Con
tact
-con
tact
Test
vol
tage
(kV
rm
s)C
onta
ct-s
hell
Rat
ed c
urre
nt (A
)
Low Voltage contactFluidic contact
1
2
4
3
1
2
4
3
Ref
eren
ce
Contact Solder Crimptype contact contact
P11
P12
P13
P15
P20
P22
P23
P25
P28
P40
P49
P33
P36
P26
P28
P29
3.0 1.84.0 2.0
3.0 1.84.0 2.0
3.0 1.84.0 2.0
3.0 1.84.0 2.0
3.0 1.84.0 2.0
3.0 1.84.0 2.0
3.0 1.84.0 2.0
3.0 1.84.0 2.0
3.0 1.84.0 2.0
4 P1 3.0 1.8 6 – – – – – – – – –
4 P1 3.0 1.8 6 9 0.7 l l 1.00 1.00 0.80 0.80 8
3 P1 3.0 1.8 6 6 0.7 l l 0.90 0.95 0.80 0.80 8
3 P1 3.0 1.8 6 12 0.7 l l 0.90 0.95 0.80 0.80 6
2 P1 3.0 1.8 6 12 0.9 l l 0.95 0.85 0.90 1.20 10
2 P1 3.0 1.8 6 16 0.9 l l 0.95 0.85 0.85 0.85 10
2 P1 3.0 1.8 6 18 0.7 l l 0.90 0.95 0.85 0.75 8
Multi fluid and Mixed fluid + LV
ø A
Male solder contacts Female solder contactsø
A
Male crimp contacts Female crimp contacts
2B2K
3B3K
4B4K
Insert configuration
10www.lemo.com
® ®
Contact for plug, receptacle, and fixed receptacle
Ref.
ACLMZ
Contact type
male soldermale crimpfemale solderfemale crimpno contact
Electrical Contact
P01
P30
P40
5B5K
10 P1 3.0 1.8 6 – – – – – – – – –
3 P3 6.0 4.0 6 – – – – – – – – –
4 P3 6.0 4.0 6 – – – – – – – – –
Nb
of fl
uidi
c tu
be
Type
Ext
. ø o
f tub
e
Int.
ø of
tub
e
Max
. wor
king
pre
ssur
e (b
ars)
Con
tact
No
ø A
(mm
)
Sol
der
Crim
p
Test
vol
tage
(kV
rm
s)C
onta
ct-c
onta
ctTe
st v
olta
ge (k
V r
ms)
Con
tact
-she
llTe
st v
olta
ge (k
V r
ms)
Con
tact
-con
tact
Test
vol
tage
(kV
rm
s)C
onta
ct-s
hell
Rat
ed c
urre
nt (A
)
Low Voltage contactFluidic contact
Ref
eren
ce
Contact Solder Crimptype contact contact
Multi fluid and Mixed fluid + LV
ø A
Male solder contacts Female solder contacts
ø A
Male crimp contacts Female crimp contacts
Outer shell and collet nut Latch sleeve + earthing crown Other metallic components
Material Surf. treatment Material Surf. treatment Material Surf. treatment
Brass chrome brass/bronze nickel 2) brass nickelPEEK (natural) – brass/bronze nickel 2) brass nickel Only for FGG and ENG (B series)
PSU – brass/bronze nickel 2) brass nickel Only for FGY and ENY (B series) 1)
Remarks
CGP
Ref.
Note: 1) see «variant» for the color. 2) in the K series, the latch sleeve is chrome-plated.
Housings (B and K series)
11www.lemo.com
® ®
D 11D 13D 15D 17D 19D 21D 23D 25
11.8 – 11.5 9.613.8 – 13.5 11.615.8 – 15.5 13.617.8 – 17.5 15.619.8 – 19.5 17.621.8 – 21.5 19.623.8 21.8 23.5 21.625.3 21.8 25.0 23.6
5B
M 62M 72M 82M 92D 10D 12D 13D 15D 16
6.2 – 6.0 5.17.2 – 7.0 6.18.2 – 8.0 7.19.2 8.6 9.0 8.110.8 – 10.5 9.112.3 – 12.0 10.613.8 12.5 13.5 12.115.3 12.5 15.0 13.616.3 12.5 16.0 15.1
4B
Reference
Type Code
D and M type collets for B series
M 42D 52D 62D 72D 82D 92D 99
4.2 – 4.0 3.15.2 – 5.0 4.16.2 – 6.0 5.17.2 – 7.0 6.18.2 – 8.0 7.19.2 8.6 9.0 8.19.9 8.6 9.7 9.1
2B
M 52D 62D 72D 82D 92D 10D 11D 12
5.2 – 5.0 4.16.2 – 6.0 5.17.2 – 7.0 6.18.2 – 8.0 7.19.2 – 9.0 8.110.2 – 10.0 9.111.2 10.2 11.0 10.111.9 10.2 11.7 11.1
3B
Reference
Type Code
ø B ø A
D type
M type
Collets (B and K series)
Note: 1) these collets cannot be used for connector models with nutfor fitting a bend relief.All dimensions are in millimeters.
Collet ø Cable ø
ø A ø B max. min.Notes
Collet ø Cable ø
ø A ø B max. min.Notes
1)
1)
1)
1)
1)
1)
1)
1)
120www.lemo.com
® ®
Reference
Type Code
Reference
Type Code
C and K type collets for K series
Note: all dimensions are in millimeters.
C type
K type
oversizecable collet
ø B ø A ø B ø A
ø B ø A
ø B ø A
C 35C 40C 45C 50C 55C 60C 65C 70C 75C 80C 85K 90K 95K 10K 11
4.2 – 3.5 3.14.2 – 4.0 3.65.2 – 4.5 4.15.2 – 5.0 4.66.2 – 5.5 5.16.2 – 6.0 5.67.2 – 6.5 6.17.2 – 7.0 6.68.2 8.2 7.5 7.18.2 8.2 8.0 7.69.2 8.6 8.5 8.19.2 – 9.0 8.610.2 10.2 9.5 9.110.2 10.2 10.0 9.611.2 10.6 10.5 10.1
2KC 50C 55C 60C 65C 70C 75C 80C 85C 90C 95C 10C 11C 12C 13C 14C 15K 16K 17K 18K 19K 20K 21K 22K 23
6.3 – 5.0 4.66.3 – 5.5 5.16.3 – 6.0 5.67.3 – 6.5 6.17.3 – 7.0 6.68.3 – 7.5 7.18.3 – 8.0 7.69.3 – 8.5 8.19.3 – 9.0 8.610.8 – 9.5 9.110.8 – 10.5 9.612.3 – 12.0 10.613.8 13.8 12.8 12.113.8 13.8 13.5 12.915.3 15.3 14.0 13.615.3 15.3 15.0 14.117.8 – 16.5 15.617.8 – 17.5 16.619.8 – 18.5 17.619.8 – 19.5 18.621.8 – 20.5 19.621.8 – 21.5 20.623.8 23.8 22.5 21.623.8 23.8 23.5 22.6
4K
C 10C 11C 12C 13C 14C 15C 16C 17C 18C 19C 20C 21C 22C 23
11.8 – 10.5 9.611.8 – 11.5 10.613.8 – 12.5 11.613.8 – 13.5 12.615.8 – 14.5 13.615.8 – 15.5 14.617.8 – 16.5 15.617.8 – 17.5 16.619.8 – 18.5 17.619.8 – 19.5 18.621.8 – 20.5 19.621.8 – 21.5 20.623.8 23.8 22.5 21.623.8 23.8 23.5 22.6
5K
Collet ø Cable ø
ø A ø B max. min.
Collet ø Cable ø
ø A ø B max. min.
C 30C 35C 40C 45C 50C 55C 60C 65C 70C 75C 80C 85C 90C 95C 10C 11K 11K 12K 13K 14K 15
3.2 – 3.0 2.64.2 – 3.5 3.14.2 – 4.0 3.65.2 – 4.5 4.15.2 – 5.0 4.66.2 – 5.5 5.16.2 – 6.0 5.67.2 – 6.5 6.17.2 – 7.0 6.68.2 – 7.5 7.18.2 – 8.0 7.69.2 – 8.5 8.19.2 – 9.0 8.610.2 10.2 9.5 9.110.2 10.2 10.0 9.611.2 10.6 10.5 10.112.3 – 12.0 10.613.8 13.8 12.8 12.113.8 13.8 13.5 12.915.3 15.3 14.0 13.615.3 15.3 15.0 14.1
3K
Extractor
Reference
DCC.91.10P.1LADCC.91.10P.3LA
Contact type
P1P3
Tools
13www.lemo.com
® ®
4.0 36 4.5 4.04.5 36 5.0 4.56.0 36 6.5 6.07.0 36 7.7 7.0
6.0 42 6.9 6.07.0 42 7.9 7.08.0 42 8.9 8.0
11.0 60 11.9 11.012.0 60 13.0 12.013.5 60 14.5 13.5
2B-2K
3B-3K
4B-4K-5B
Part number
Dimensions (mm)Bend relief Cable ø
A L max. min.Series
GMA.2B.040.DGGMA.2B.045.DGGMA.2B.060.DGGMA.2B.070.DG
GMA.3B.060.DGGMA.3B.070.DGGMA.3B.080.DG
GMA.4B.011.DGGMA.4B.012.DGGMA.4B.013.DG
A bend relief made from thermoplastic polyurethane elas-tomer (Desmopan 786) can be fitted over LEMO plugsand receptacles that are supplied with nut for fitting suchbend relief. They are available in nine different colors thatmatch with the GRA insulating washers (see unipole-mul-tipole catalog). Use the part numbers shown below toorder this accessory separately.
Bend relief (Polyurethane)GMl
Note: the last letter «G» of the part number indicates the gray color of the bend relief. For ordering a bend relief with another color, see table above andreplace the letter «G» by the letter of the required color.
L
ø A
Main characteristics
l Material: Polyurethane elastomerl Temperature range in dry atmosphere: -40°C +80°C
Ref.
ABGJM
Color
bluewhitegrayyellowbrown
Ref.
NRSV
Color
blackredorangegreen
GMA.2B.lll.ll
GMA.2B.lll.ll
GMA.1B.lll.ll
GMA.3B.lll.ll
GMA.2B.lll.ll
GMA.4B.lll.ll
GMA.4B.lll.ll
GMA.4B.lll.ll
C 35 to 85K 90 to 10
C 30 to 10K 11 to 15
C 50 to 15
2K
3K
4K
M 42D 52 to 92
M 52D 62 to 11
M 62 and 72M 82 and 92D 10 to 15
D 11 to 15
2B
3B
4B
5B
Collet
Type Code
Bend relief for B series models with collet
Need to be orderedseparatelyR
ef. Collet
Type Code
Need to be orderedseparatelyR
ef.
Z
Z
Z
Z
Z
Z
Z
Note: All dimensions are in millimeters.
Need to be ordered
Bend relief for K series models with collet
Variant (B and K series)
GMA.2B.lll.ll
GMA.3B.lll.ll
GMA.3B.lll.ll
GMA.4B.lll.ll
GMA.4B.lll.ll
Need to be ordered
14www.lemo.com
® ®
PLEASE READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY AND CONSULT ALL RELEVANT NATIONAL ANDINTERNATIONAL SAFETY REGULATIONS FOR YOUR APPLICATION.IMPROPER HANDLING, CABLE ASSEMBLY, OR WRONG USE OF CONNECTORS CAN RESULT IN HAZARDOUSSITUATIONS.
1. SHOCK AND FIRE HAZARDIncorrect wiring, the use of damaged components, presence of foreign objects (such as metal debris), and / or residue (such as cleaning fluids), can result in short circuits, overheating, and / or risk of electric shock.Mated components should never be disconnected while live as this may result in an exposed electric arc and local overheating, resulting in possible damage to components.
2. HANDLINGConnectors and their components should be visually inspected for damage prior to installation and assembly. Suspect components should be rejected or returned to the factory for verification.Connector assembly and installation should only be carried out by properly trained personnel. Proper tools must be usedduring installation and / or assembly in order to obtain safe and reliable performance.
3. USEConnectors with exposed contacts should never be live (or on the current supply side of a circuit). Under general conditions voltages above 30 VAC and 42 VDC are considered hazardous and proper measures should be taken to eliminate all risk of transmission of such voltages to any exposed metal part of the connector.
4. TEST AND OPERATING VOLTAGESThe maximum admissible operating voltage depends upon the national or international standards in force for the application in question. Air and creepage distances impact the operating voltage; reference values are indicated in the catalog however these may be influenced by PC board design and / or wiring harnesses.The test voltage indicated in the catalog is 75% of the mean breakdown voltage; the test is applied at 500 V/s and the test duration is 1 minute.
5. CE MARKINGCE Marking is applied to a complete product or device, and implies that the device complies with one or severalEuropean safety directives.CE Marking can not be applied to electromechanical components such as connectors.
6. PRODUCT IMPROVEMENTSThe LEMO Group reserves the right to modify and improve to our products or specifications without providing prior notification.
Product safety notice
Addendum for
Fluidic / Pneumatic
Without Valve
16www.lemo.com
® ®
Part Section Showing Internal Components (Monofluidic – Series 0B)
Model DescriptionMonofluidic (Series 00)
FFA Straight plug with cable colletPCA Free receptacle with cable colletPSA Fixed receptacle, nut fixing,
with cable collet
Monofluidic (Series 0B) FGG Straight plug with key (G) or keys (code
A....M) and cable colletPHG Free receptacle with key (G) or keys
(code A....M) and cable colletPSA Fixed receptacle, nut fixing, with key (G)
or keys (code A....M) and cable collet
Multifluidic and Mixed (Series 2B-4B)EGG Fixed receptacle nut fixing, with key (G)
or keys (code A....M)FGG Straight plug with key (G) or keys (code
A....M) and cable colletPHG Free receptacle with key (G) or keys (code
A....M) and cable colletPKG Fixed receptacle, nut fixing, with key (G) or keys
(code A....M) and cable collet
Technical CharacteristicsMaterial and Treatment Mechanical and Climatic
Brass (UNS C 38500)Aluminum ( AISI 6262)Special brassBrass (UNS C 38500)Brass (UNS C 38500)Bronze (UNS C 52100)PEEK (MIL-P- 46183)Brass (UNS C 38500)Bronze (UNS C 54400)Silicone rubber
Outer shell andCollet nutLatching sleeveTube supportRetaining ringLocking washerInsulatorMale contactFemale contactO-ring
Material (Standard)Component
bar
cycles
˚C
Max. workingpressure
Endurance
Operatingtemperature
Unit
2
00
2
0B
0.5
2B
0.5
3BCharacteristics
Note: flow direction is always from female contact to male contact.
4 5 1 6 2 3 3 6 1 2 5 41
2
3
4
5
6
Fixed Receptacle
shell
hexagonal nut
locking washer
collet nut
tube support
retaining ring
1
2
3
4
5
6
Straight Plug
outer shell
latch sleeve
O-ring
collet nut
tube support
retaining ring
Surface treatment (µm)
Cu Ni Cr Au
0.5 3 0.3anodized
0.5 30.5 30.5 30.5 3
0.5 3 1.50.5 3 2.0
Series
>1000
-15+30 (+5˚F + 86˚ F)
The surface treatment standards are as follows:
– Nickel FS-QQN-290A
– Chrome FS-QQ-C-320B
Fluidics Connectors Series 00-BLEMO fluidic connectors find many applications in the medical, dental and other industries that require precise,dependable fluidic connections. Fluidic connectors may be of the monotube type available in the Series 00 and 0B orof the multitube type and/or mixed with electrical contacts available in the Series 2B, 3B and 4B. Mixed connectorscombining fluidic and signal contacts are also available. Please see LEMO’s Unipole Mulitpole catalog for more infor-mation. Fluidic connectors may also be sued in pneumatic applications. Contact LEMO USA for custom applications
InterconnectionsSeries 00 Series B
Straight Plug Straight Receptacle Straight Plug Fixed Receptacle Straight Receptacles
FFA PCA FGG EGG PHG
PSA PKG
17www.lemo.com
® ®
FGG 0B 010 C Z Z N 50
Model: see below
Part Number Example
Series: 00/0B-2B-3B-4B
Type: pages 18 and 19
Housing: C= chrome plated brass (standard)L= anodized aluminum3 (on request)s= stainless steel (on request)
Insulator: L= PEEKZ= without insulator1
Variant3
ø Tube or collet:page 11
Fixing type:D – cable collet
N – tube support1
Contact type:A – male solderC – male crimp
L – female solderM – female crimp
Z – without contact2
FGG.0B.010.CZZN50 Straight plug with key (G), 0B series, multifluidic; type fitted with one fluidictube, chrome-plated brass outer housing, nickel plated brass tube support for a 5.0 mm OD tube.
Notes:
1) For monofluidic (010) types only.2) For monofluidic (010) and multifluidic (040) types only.3) The ‘variant’ position of the part number is used to indicate the
anodizing color of aluminum shells. The colors available and their corresponding reference letters are to the right.
Note: All dimensions are in millimeters.
Series 00
FFA PCA PSA
Series B
FGG EGG PKG
PHG
Ref.
RTV
Anodizingcolor
rednaturalgreen
Ref.
A
J
N
Anodizingcolor
blueyellowblack
Model Dim. Series0B 2B 3B 4B
FGGAL
EGGAeL
PHGAL
EGGAeL
9.5 15.0 18.0 25.0
36.0 49.0 18.0 25.0
– 18.0 22.0 28.0
– M15x1 M18x1M25x1
– 31.5 34.5 37.5
9.5 16.5 19.0 24.4
35.0 47.0 56.0 73.0
10.0 18.0 22.0 28.0
M9x0.6 M15x1M18x1 M25x1
35.5 37.0 56.0 73.0
~26
ø6,4
~25
ø6,4
~24,5
ø8
M7x0,5
~L
øA
~L
øA
e
~L
øA
e
~L
øA
18www.lemo.com
® ®
Types
Fluidics and Fluidics + LV
00
0B0K
2B
2K
1) Refer to the table for the diameters of the collets.
2) For the monofluidic connector types (00, 0B) this diameter indicates the outside diameter of the fluidic tube being fitted.
l Available
ll On request
All the “B” Series inserts may be used in our Environmental “K” Series.
Please see our K/E catalog for shell configurations.
Sta
ndar
d G
roup
Wat
ertig
ht G
roup
Num
ber
of T
ubes
O.D
. of T
ube
I.D. o
f Tub
e
I.D. o
f Con
tact
Max
. wor
king
pre
ssur
e (b
ar)
Num
ber
of C
onta
cts
Con
tact
ø
Sol
der
Crim
p
Wor
king
Vol
tage
(kv
rms)
Wor
king
Vol
tage
(kv
dc)
Test
Vol
tage
(kv
rm
s)
Test
Vol
tage
(kv
dc)
Rat
ed C
urre
nt (
A)
Tube
or
Col
let
ø2
00 – 1 2.2 1.4 0.9 2.0 – – – – – – – – – 22R
efer
ence
010
00 – 1 3.2 1.9 0.9 2.0 – – – – – – – – – 32010
0B 0K 1 5.0 4.0 1.6 2.0 – – – – – – – – – 50
2B 2K 1 2.6 2.2 1.3 0.5 4 0.9 l l 0.33 0.50 1.0 1.50 8 1)
010
2B 2K 1 3.6 3.2 1.6 0.5 6 0.7 l ll 0.40 0.60 1.2 1.80 5 1)
2B 2K 1 2.6 2.2 1.3 0.5 10 0.7 l ll 0.33 0.50 1.0 1.50 4 1)
012
013
015
Fluidic
Contact type
Low Voltage (LV)
19www.lemo.com
® ®
Types
Fluidics and Fluidics + LV
3B
3K
4B
4K
1) Refer to the table for the diameters of the collets.
2) For the monofluidic connector types (00, 0B) this diameter indicates the outside diameter of the fluidic tube being fitted.
l Availablell On request
All the “B” Series inserts may be used in our Environmental “K” Series.
Please see our K/E catalog for shell configurations.
Sta
ndar
d G
roup
Wat
ertig
ht G
roup
Num
ber
of T
ubes
O.D
. of T
ube
I.D. o
f Tub
e
I.D. o
f Con
tact
Max
. wor
king
pre
ssur
e (b
ar)
Num
ber
of C
onta
cts
Con
tact
ø
Sol
der
Crim
p
Wor
king
Vol
tage
(kv
rms)
Wor
king
Vol
tage
(kv
dc)
Test
Vol
tage
(kv
rm
s)
Test
Vol
tage
(kv
dc)
Rat
ed C
urre
nt (
A)
Tube
or
Col
let
ø2
3B 3K 2 2.6 2.2 1.3 0.5 4 0.9 l l 0.40 0.60 1.2 1.80 8 1)R
efer
ence
022
3B 3K 2 2.6 2.2 1.3 0.5 6 0.9 l l 0.40 0.60 1.2 1.80 8 1)023
3B 3K 2 2.6 2.2 1.3 0.5 10 0.7 l ll 0.20 0.28 0.6 0.85 5 1)025
3B 3K 4 2.0 1.6 0.7 0.5 – – – – – – – – – 1)040
3B 3K 4 2.0 1.6 0.7 0.5 4 0.7 l ll 0.20 0.28 0.6 0.85 5 1)042
4B 4K 2 2.6 2.2 1.3 0.5 12 0.9 l l 0.40 0.60 1.2 1.80 4 1)026
4B 4K 2 2.6 2.2 1.3 0.5 16 0.9 l l 0.40 0.60 1.2 1.80 4 1)028
4B 4K 4 2.6 2.2 1.3 0.5 9 0.7 l ll 0.33 0.50 1.0 1.50 3 1)049
Fluidic
Contact type
Low Voltage (LV)
21www.lemo.com
® ®
The brands of LEMO, are LEMO, REDEL and Coelver.
The REDEL brand also has fluidic / pneumatic solutions,please see the REDEL catalog. For R series fluidic / pneumat-ic hybrid solutions please see the R series catalog
LEMO HEADQUARTERS
SWITZERLANDLEMO SA Chemin des Champs-Courbes 28 - P.O. Box 194 - CH-1024 EcublensTel. (+41 21) 695 16 00 - Fax (+41 21) 695 16 01 - e-mail: [email protected]
LEMO SUBSIDIARIES
AUSTRIALEMO Elektronik GesmbHLemböckgasse 49/E6-31230 WienTel: (+43 1) 914 23 20 0Fax: (+43 1) 914 23 20 [email protected]
CHINALEMO Trading (Shanghai) Co., Ltd.LEMO Electronics (Shanghai) Co.,Ltd.5th Floor, Block 6, City of ELITE,1000 Jinhai Road, PudongShanghai, China 201206Tel: (+86 21) 5899 7721Fax: (+86 21) 5899 [email protected]
DENMARKLEMO DENMARK A/SGammel Mosevej 462820 GentofteTel: (+45) 45 20 44 00Fax: (+45) 45 20 44 [email protected]
FRANCELEMO FRANCE Sàrl15/19 Avenue Graham Bell Espace Vinci-Bussy Saint Georges 77607 MARNE LA VALLEE Cedex 3Tel: (+33 1) 6094 6094Fax: (+33 1) 6094 [email protected]
GERMANYLEMO Elektronik GmbHHanns-Schwindt-Str. 681829 München Tel: (+49 89) 42 77 03Fax: (+49 89) 420 21 [email protected]
HONG KONGLEMO Hong Kong Ltd.Room 33. 7th FloorHITEC, 1 Trademart DriveKowloon Bay - Hong KongTel: (+852) 21 74 04 68Fax: (+852) 21 74 04 [email protected]
HUNGARYREDEL Elektronika KftVágóhíd u. 261201 Budapest XX.Tel: (+36 1) 421 47 10Fax: (+36 1) 421 47 [email protected]
ITALYLEMO ITALIA srlViale Lunigiana 25, 20125 MilanoTel: (+39 02) 66 71 10 46Fax: (+39 02) 66 71 10 [email protected]
JAPANLEMO JAPAN Ltd4-10-3, Takaido Higashi, Suginami-ku, Tokyo, 168-0072Tel: (+81 3) 53 44 39 33Fax: (+81 3) 53 44 39 [email protected]
NETHERLAND / BELGIUMLEMO Connectors Nederland B.V.De Trompet 2108 1967 DC HeemskerkTel: (+31 0) 251 25 78 20Fax: (+31 0) 251 25 78 [email protected]
NORWAY / ICELANDLEMO NORWAY A/SStanseveien 6B, 0975 OsloTel: (+47) 22 91 70 40Fax: (+47) 22 91 70 [email protected]
SPAIN / PORTUGALIBERLEMO S.A.Brasil, 45, 08402 GranollersBarcelonaTel: (+34 93) 860 44 20Fax: (+34 93) 879 10 [email protected]
Madrid OfficeAntonio López, 9628019 MadridTel: (+34 91) 469 99 19Fax: (+34 91) 469 99 59
SWEDEN / FINLANDLEMO Nordic ABMariehällsvägen 39A168 65 BrommaTel: (+46 8) 635 60 60Fax: (+46 8) 635 60 [email protected]
SWITZERLANDLEMO VERKAUF AGGrundstrasse 22B6343 RotkreuzTel: (+41 41) 790 49 40Fax: (+41 41) 790 49 [email protected]
UNITED KINGDOMLEMO UK LtdUnit 15 & 16 Hazelwood Trading EstateWorthing, West Sussex, BN14 8NPTel: (+44 1903) 23 45 43Fax: (+44 1903) 20 62 [email protected]
CA
T.F
L.L
US
.P0
20
9
LEMO USA, Inc. 800-444-5366email: [email protected]
www.lemo.com