plc, dcs & plc vs dcs by j s shekhawat
DESCRIPTION
Basics of DCS PLC & Difference Between themTRANSCRIPT
![Page 1: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/1.jpg)
Prepared By:J S Shekhawat
Sr. Engg. C&I
![Page 2: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/2.jpg)
(Programmable Logic Controller)
Prepared By:J S Shekhawat
Sr. Engg C&I
![Page 3: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/3.jpg)
What is PLC?
PLC is a Programmable Logic Controller and also
a kind of a digital computer which can be
Programmed as per the process which is needed
to be controlled, designed for multiple inputs
and output arrangements, having immunity to
electrical noise and resistance to vibration and
impact.
![Page 4: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/4.jpg)
History of PLC
PLC was introduced in late 1960’s
First commercial & successful Programmable Logic
Controllers was designed and developed by Modicon
as a relay replacer for General Motors.
Earlier, it was a machine with thousands of electronic parts.
Later ,in late 1970’s,the microprocessor became reality & greatly enhanced the role of PLC permitting it to evolve form simply relay to the sophisticated system as it is today.
![Page 5: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/5.jpg)
Major Components of a PLC
CENTRAL PROCESSING
UNIT (CPU)
POWERSUPPLY
I MN O P D U UT L
E
O M U OT DP UU LT E
PROGRAMMING DEVICE
From SENSORSPushbuttons,
contacts,limit switches,
etc.
ToOUTPUT
Solenoids, contactors,
alarmsetc.
Handheld Device or Computer
etc.
![Page 6: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/6.jpg)
Major Components of a PLC
![Page 7: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/7.jpg)
Major Components of a PLC Central Processing Unit It is a micro-controller based circuitry. The CPU consists of
following blocks :Arithmetic Logic Unit (ALU), Program memory, Process image
memory (Internal memory of CPU), Internal timers and counters.
CPU performs the task necessary to fulfill the PLC funtions. These tasks include Scanning, I/O bus traffic control, Program execution, Peripheral and External device communication, special functions or data handling execution and self diagnostics.
![Page 8: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/8.jpg)
Input module
These modules act as interface between real-time status of process variable and the CPU.
Analog input module : Typical input to these modules is 4-20 mA, 0-10 V
Example : Pressure, Flow, Level Tx, RTD (Ohm), Thermocouple (mV)
Digital input module : Typical input to these modules is 24 V DC, 115 V AC, 230 V AC
Ex. : Switches, Pushbuttons, Relays, pump valve on off status
![Page 9: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/9.jpg)
Output module
These modules act as link between the CPU and the output devices in the field.
Analog output module : Typical output from these modules is 4-20 mA, 0-10 V
Ex : Control Valve, Speed, Vibration.Digital output module : Typical output from these modules is
24 V DC, 115 V AC, 230 V AC Ex. : Solenoid Valves, lamps, Actuators, dampers, Pump
valve on off control
![Page 10: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/10.jpg)
Power Supply
The power supply gives the voltage required for electronics module (I/O Logic signals, CPU, memory unit and peripheral devices) of the PLC from the line supply.
The power supply provides isolation necessary to protect the solid state devices from most high voltage line spikes.
As I/O is expanded, some PLC may require additional power supplies in order to maintain proper power levels.
![Page 11: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/11.jpg)
Bus System
It is path for the transmission of the signal . Bus system is responsible for the signal exchange between processor and I/O modules.
The bus system comprise of several single line i.e. wires / tracks
![Page 12: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/12.jpg)
PLC operation sequence
1) Self test: Testing of its own hardware andsoftware for faults.
2) Input scan: If there are no problems, PLC will copy all the inputs and copy their valuesinto memory.
3) Logic solve/scan: Using inputs, the ladderlogic program is solved once and outputs are updated.
4) Output scan: While solving logic the outputvalues are updated only in memory when ladder scan is done, the outputs will be updated using temporary values in memory.
Self test
Input scan
Logic scan
Outputscan
![Page 13: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/13.jpg)
Programming Languages of PLC
Most common languages encountered in PLC programming are:
1) Ladder Logic
2) Functional Block Diagram
3) Sequential Function Chart
![Page 14: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/14.jpg)
Ladder Logic
The ladder logic is the oldest programming language for PLC.
It is well suited to express Combinational logic.
The main ladder logic symbols represent the elements :
make contact
break contact
relay coil
![Page 15: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/15.jpg)
Block diagram of a PLC
Outputs
LEDs
Inputs
![Page 16: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/16.jpg)
Programming Example:Ladder Logic Program for Start/Stop of Motor :
X2X1
Y1
Y1
![Page 17: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/17.jpg)
Programming PLC:
![Page 18: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/18.jpg)
Starting of Motor:
![Page 19: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/19.jpg)
Continuous Running of motor when Start Button is released:
![Page 20: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/20.jpg)
To Stop the Motor :
![Page 21: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/21.jpg)
PLC Selection Criteria Cost of hardware, software, Integration Engineering, Design, Installation,
Start-up and Commissioning, Validation documentation and Execution, Training, Spare parts, Maintenance, System service contract and system life cycle.
Reliability, Flexibility, Scalability and Validatability.
Ease of Database configuration, Graphics development, Interlocks and Batch processing.
Integration of High-level Application.
Control Philosophy for Centralized versus Remote Operator Console or both.
![Page 22: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/22.jpg)
Advantages of PLCs: Reliability.
Flexibility in programming and reprogramming.
Cost effective for controlling complex systems.
Small physical size, shorter project time.
High speed of operation.
Ability to communicate with computer systems in the plant.
Ease of maintenance /troubleshooting.
Reduced space.
Energy saving.
![Page 23: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/23.jpg)
Disadvantages of PLCs
PLC devices are proprietary it means that part or software of one manufacturer can’t be used in combination with parts of another manufacturer.
Limited design and cost option
Fixed Circuit Operations.
PLCs manufacturers offer only closed architectures.
![Page 24: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/24.jpg)
Applications:
Wherever automation is desired the PLCs are best
suited to meet the task.
Few examples of industries where PLCs are used :
1) Robots : manufacturing and control
2) Car park control
3) Train control station system
4) Food processing
5) Materials handling
6) Machine tools
7) Conveyer system etc.
![Page 25: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/25.jpg)
(Distributed Control System)
Prepared By:J S Shekhawat
Sr. Engg C&I
![Page 26: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/26.jpg)
Distributed control system (DCS) DCS is a system of dividing plant or process control into
several areas of responsibility, each managed by its own controller, with the whole system connected to form a single entity, usually by means of communication buses. Distributed Control System (DCS) refers to a control system usually of a manufacturing system, process or any kind of dynamic system, in which the controller elements are not central in location (like the brain) but are distributed throughout the system with each component sub-system controlled by one or more controllers. The entire system of controllers is connected by networks for communication and monitoring.
The entire system of controllers is connected by networks for communication and monitoring.
![Page 27: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/27.jpg)
Why it is called DISTRIBUTED???As is apparent from the abbreviation, the word ‘Distributed’supports following functionality’s
Physical Distribution - Nodes or Subsystems can beDistributed i.e. located physically apart
Functional Distribution - Specific Functionality is impartedfor a Node basing on the combination of hardware andsoftware used. For e.g. Application work-processor withHistorian, Application work-processor with controlconfiguration software
Structural Distribution - Different Structural hardwareplatforms (Application Workstation processor, Workstationprocessor, Control processor etc.) are used to achieve therequired functionality.
![Page 28: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/28.jpg)
What does DCS System consists of?DCS System consists minimum of the following components.
Field Control station (FCS): It consists of input/output modules, CPU and communication bus.
Operator station: It is basically human interface machine with monitor, the operator man can view the process in the plant and check if any alarm is presents and he can change any setting, print reports..etc...
Engineering station: It is used to configure all input & output and drawing and any things required to be monitored on Operator station monitor.
![Page 29: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/29.jpg)
![Page 30: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/30.jpg)
Process Control Systems
![Page 31: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/31.jpg)
Process Control Systems
![Page 32: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/32.jpg)
Digital Control System
Drawbacks Of CCS:
If the CPU fails the entire plant gets affected.
Redundancy concept is not available.
Redundancy is having two controllers. One would be active and the other would be standby. If the active controller fails, the standby controller takes over.
![Page 33: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/33.jpg)
Digital Control System
![Page 34: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/34.jpg)
How does it work?
Example of simple control mechanism
Process measured value (PV) Manipulated value (MV) Set Value (SV).
![Page 35: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/35.jpg)
Operation WindowsInformation regarding the process is gathered as well asmonitored by the following Standard Operation windows : Tuning Window Control Group Window Trend Window Process Alarm Window Operator guide Message Window Graphic Window Overview Window Process Report Window Historical Report Window
![Page 36: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/36.jpg)
Control function is distributed among multiple CPUs (Field Control Stations). Hence failure of one FCS does not affect the entire plant.
Redundancy is available at various levels. Instruments and interlocks are created by software. Generation and modifications of the interlocks are very
flexible and simple. Information regarding the process is presented to the
user in various formats. Field wiring is considerably less. Maintenance and trouble shooting becomes very easy. Cost effective in the long run.
Advantages of DCS
![Page 37: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/37.jpg)
WHY DCS ? For Total Plant Automation
For Higher Productivity
For Optimal Process Control
For Advance Process Control
For Regulatory Compliance
For Management Information System
In Tune With Global Requirement
![Page 38: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/38.jpg)
DCS MANUFACTURERS ASEA BROWN BOWERI - ABB TATA HONEYWEL FOXBORO - INVENSYS YOKOGOWA BLUE STAR - YBL ALLEN BRADLEY GE FANUC FISHER ROSEMOUNT TOSHIBA METSO Automation
![Page 39: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/39.jpg)
(Basic Difference between PLC & DCS)
Prepared By:J S Shekhawat
Sr. Engg C&I
![Page 40: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/40.jpg)
Difference Between PLC & DCS A PLC is cost-effective up to a certain I/O count, and so is the
DCS. But the difference is in their starting points: the PLC iscost-effective from 0 to a few thousand I/O points; the DCSbecomes cost-effective starting from a few thousand points andbeyond.
A PLC becomes a subsystem of the DCS in rare occasions whenthe situation calls for it, i.e., purchase of huge package systemswith engineering schedules incompatible with the DCS schedule(I/O lists cannot be submitted on time before the DCS hardwarefreeze date). Note that this package system is a process systemusing continuous control, not discrete. Based on this, a PLC cannever be larger than a DCS in terms of I/O count.
In large plants the DCS is king because most owners want a singlesource of hardware support and service, and this mentalitynaturally denies the PLC a foothold. Package vendors are nolonger required to provide PLC for their system. Everything isconnected to the DCS.
![Page 41: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/41.jpg)
Difference Between PLC & DCS Cont… Generally, PLCs are stand alone and perform a particular task,
where a DCS is a network of PLCs that communicate in somefashion to accomplish a particular task. For example, in a waterfiltration plant, there might be a PLC that is used to perform abackwash of a particular filter, in that same water plant a DCSmay be communicating with 14 filter PLCs and starting thebackwash routine when required.
PLC only handle sequential process than DCS can handled bothContinue process and large loop control.
If we see from security angle, PLC doesn't have dongle so peoplecan crack the software easy. DCS have a dongle so it's onlylicense to industry which have it.
PLC is a programmable Logic controller which is used mainly forinterlocking different equipment’s. DCS is Distributed ControlSystems which is used to control very big plants by using simpleGUI screens. PLCs are interfaced with DCS for interlocking.
![Page 42: Plc, dcs & plc vs dcs by j s shekhawat](https://reader031.vdocuments.site/reader031/viewer/2022012307/54710fceb4af9fae0a8b4a25/html5/thumbnails/42.jpg)
Thank You!!!