PLAN SECTION A-A END A A REV - SHEET DOCUMENT NUMBER 9001390000 1 OF 1 TITLE VERTICAL PRESSURE FILTER GENERAL ARRANGEMENT 4'-0" DIAMETER, 5'-0" STRAIGHT SIDE, 3 TANK, WATERWASH JA20 BA91 DESIGNER CHECKER APPROVER THIS DRAWING IS PROPERTY OF WESTECH ENGINEERING, INC. AND IS TRANSMITTED IN CONFIDENCE. NEITHER RECEIPT NOR POSSESSION CONFERS OR TRANSFERS ANY RIGHTS TO REPRODUCE, USE, OR DISCLOSE, IN WHOLE OR IN PART, DATA CONTAINED HEREIN FOR ANY PURPOSE, WITHOUT THE WRITTEN PERMISSION OF WESTECH ENGINEERING, INC. DATE C:\vault\Design\Standard Products\General Filter\9000\900139 VPF 48X60\Waterwash 3 Tank Arrangement\Workgroup\IDW Files\9001390000-GA.idw ADDITIONAL NOTES: 1.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST. ADDITIONAL PIPING, PIPE SUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDED WITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTS TO BE INSTALLED AT JOBSITE, BY CUSTOMER. 2.) WHEN PRESSURE AERATION OCCURS BEFORE FILTRATION THERE NEEDS TO BE A PROVISION MADE FOR AIR RELEASE IN THE HIGHEST POINT OF THE INLET PIPING. 3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTING ENGINEER. 4.) PIPE SUPPORTS ARE NOT SHOWN. TO BE DESIGNED BY THE CONSULTING ENGINEER AND SUPPLIED BY THE INSTALLING CONTRACTOR. 5.) DO NOT SUPPORT PIPING OR OTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS. 6.) MINIMUM RECOMMENDED CEILING HEIGHT: ALLOW 6" CLEARANCE ABOVE THE AIR RELEASE PIPING. 7.) BACKWASH WASTE SUMP SIZING AND LOCATION DESIGN IS BY THE CONSULTING ENGINEER. SUMP TO BE DESIGNED FOR MAXIMUM DESIGN BACKWASH RATE. 15° TYP 4'-0" TYP OUTSIDE 2'-11 5 8 " 3'-11 1 4 " 2'-6" TYP 3" INFLUENT PIPING (BY OTHERS) 3" EFFLUENT PIPING (BY OTHERS) 1'-3" TYP 4" TYP 14" X 18" MANWAY 0.75" AUTOMATIC AIR RELEASE PIPING 3" INFLUENT/BACKWASH TANK CONNECTION 3" MANUAL BACKWASH RATE SET VALVE 2" INFLUENT VALVE 3" BACKWASH WASTE VALVE 3" EFFLUENT TANK CONNECTION 3" EFFLUENT VALVE 2" DRAIN VALVE 2" DRAIN/FILTER TO WASTE PIPING NOTES: 1.) FOLLOW THE LISTED WESTECH REFERENCE DOCUMENTS EXCEPT AS NOTED ON THIS DRAWING. 2.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST. ADDITIONAL PIPING, PIPE SUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDED WITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTS TO BE INSTALLED AT THE JOBSITE BY THE INSTALLING CONTRACTOR. 3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTING ENGINEER. 4.) PIPE SUPPORTS ARE NOT SHOWN. SUPPORTS TO BE DESIGNED BY THE CONSULTING ENGINEER AND SUPPLIED BY THE INSTALLING CONTRACTOR. DO NOT SUPPORT PIPING OR OTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS. REFERENCE DOCUMENTS REV REVISION DESCRIPTION ECN DESIGNER APPROVER DATE LOSS OF HEAD INDICATOR BACKWASH RATE OF FLOW INDICATOR 5'-0" 8" 1'-8 3 4 " 5'-3 5 8 " 6'-4 3 8 " 7'-5" 9'-5 1 4 " 0'-0" 1'-1 5 8 " 8'- 7 16 " 5'-0" STRAIGHT SIDE HEIGHT

Upload: vodang

Post on 10-Mar-2019

213 views

Category:

Documents


0 download

TRANSCRIPT

PLAN

SECTION A-AEND

A A

REV

-SHEETDOCUMENT NUMBER

9001390000 1 OF 1

TITLE VERTICAL PRESSURE FILTERGENERAL ARRANGEMENT4'-0" DIAMETER, 5'-0" STRAIGHT SIDE, 3 TANK, WATERWASH

JA20BA91DESIGNER CHECKER APPROVER

THIS DRAWING IS PROPERTY OF WESTECH ENGINEERING, INC. AND IS TRANSMITTED IN CONFIDENCE. NEITHER RECEIPT NOR POSSESSION CONFERS OR TRANSFERS ANY RIGHTS TOREPRODUCE, USE, OR DISCLOSE, IN WHOLE OR IN PART, DATA CONTAINED HEREIN FOR ANY PURPOSE, WITHOUT THE WRITTEN PERMISSION OF WESTECH ENGINEERING, INC.

DATE

C:\vault\Design\Standard Products\General Filter\9000\900139 VPF 48X60\Waterwash 3 Tank Arrangement\Workgroup\IDW Files\9001390000-GA.idw

ADDITIONAL NOTES:

1.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST. ADDITIONAL PIPING, PIPESUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDED WITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTSTO BE INSTALLED AT JOBSITE, BY CUSTOMER.

2.) WHEN PRESSURE AERATION OCCURS BEFORE FILTRATION THERE NEEDS TO BE A PROVISION MADE FOR AIR RELEASE INTHE HIGHEST POINT OF THE INLETPIPING.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTING ENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. TO BE DESIGNED BY THE CONSULTING ENGINEER AND SUPPLIED BY THE INSTALLINGCONTRACTOR.

5.) DO NOT SUPPORT PIPING OR OTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

6.) MINIMUM RECOMMENDED CEILING HEIGHT: ALLOW 6" CLEARANCE ABOVE THE AIR RELEASE PIPING.

7.) BACKWASH WASTE SUMP SIZING AND LOCATION DESIGN IS BY THE CONSULTING ENGINEER. SUMP TO BE DESIGNED FORMAXIMUM DESIGN BACKWASH RATE.

15°TYP

4'-0" TYPOUTSIDE

2'-1158"

3'-1114"

2'-6"TYP

3" INFLUENT PIPING(BY OTHERS)

3" EFFLUENT PIPING(BY OTHERS)

1'-3"TYP

4" TYP

14" X 18"MANWAY

0.75" AUTOMATICAIR RELEASE

PIPING

3" INFLUENT/BACKWASHTANK CONNECTION

3" MANUAL BACKWASHRATE SET VALVE

2" INFLUENTVALVE

3" BACKWASHWASTE VALVE

3" EFFLUENTTANK CONNECTION

3" EFFLUENTVALVE

2" DRAINVALVE

2" DRAIN/FILTER TOWASTE PIPING

NOTES:

1.) FOLLOW THE LISTED WESTECH REFERENCE DOCUMENTS EXCEPT AS NOTED ON THISDRAWING.

2.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST.ADDITIONAL PIPING, PIPE SUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDEDWITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTS TO BE INSTALLED AT THEJOBSITE BY THE INSTALLING CONTRACTOR.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTINGENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. SUPPORTS TO BE DESIGNED BY THE CONSULTINGENGINEER AND SUPPLIED BY THE INSTALLING CONTRACTOR. DO NOT SUPPORT PIPING OROTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

REFERENCE DOCUMENTSREV REVISION DESCRIPTION ECN DESIGNER APPROVER DATE

LOSS OF HEADINDICATOR

BACKWASH RATEOF FLOW INDICATOR

5'-0"

8"

1'-834"

5'-358"

6'-438"

7'-5"

9'-514"

0'-0"

1'-158"

8'- 716"

5'-0"STRAIGHT

SIDEHEIGHT

PLAN

SECTION A-AEND

A A

REV

-SHEETDOCUMENT NUMBER

9001400000 1 OF 1

TITLE VERTICAL PRESSURE FILTERGENERAL ARRANGEMENT4'-6" DIAMETER, 5'-0" STRAIGHT SIDE, 3 TANK, WATERWASH

2014-10-21JA20BA91DESIGNER CHECKER APPROVER

THIS DRAWING IS PROPERTY OF WESTECH ENGINEERING, INC. AND IS TRANSMITTED IN CONFIDENCE. NEITHER RECEIPT NOR POSSESSION CONFERS OR TRANSFERS ANY RIGHTS TOREPRODUCE, USE, OR DISCLOSE, IN WHOLE OR IN PART, DATA CONTAINED HEREIN FOR ANY PURPOSE, WITHOUT THE WRITTEN PERMISSION OF WESTECH ENGINEERING, INC.

DATE

C:\vault\Design\Standard Products\General Filter\9000\900140 VPF 54X60\Waterwash 3 Tank Arrangement\Workgroup\IDW Files\9001400000-GA.idw

ADDITIONAL NOTES:

1.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST. ADDITIONAL PIPING, PIPESUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDED WITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTSTO BE INSTALLED AT JOBSITE, BY CUSTOMER.

2.) WHEN PRESSURE AERATION OCCURS BEFORE FILTRATION THERE NEEDS TO BE A PROVISION MADE FOR AIR RELEASE INTHE HIGHEST POINT OF THE INLETPIPING.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTING ENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. TO BE DESIGNED BY THE CONSULTING ENGINEER AND SUPPLIED BY THE INSTALLINGCONTRACTOR.

5.) DO NOT SUPPORT PIPING OR OTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

6.) MINIMUM RECOMMENDED CEILING HEIGHT: ALLOW 6" CLEARANCE ABOVE THE AIR RELEASE PIPING.

7.) BACKWASH WASTE SUMP SIZING AND LOCATION DESIGN IS BY THE CONSULTING ENGINEER. SUMP TO BE DESIGNED FORMAXIMUM DESIGN BACKWASH RATE.

15°TYP

4'-6" TYPOUTSIDE

3'-258"

4'-214"

2'-9"

3" INFLUENT PIPING(BY OTHERS)

4" EFFLUENT PIPING(BY OTHERS)

1'-518"

4"

14" X 18"MANWAY

0.75" AUTOMATICAIR RELEASE

PIPING3" INFLUENT/BACKWASHTANK CONNECTION

3" MANUAL BACKWASHRATE SET VALVE

2" INFLUENTVALVE

3" BACKWASHWASTE VALVE

3" EFFLUENTTANK CONNECTION

3" EFFLUENTVALVE

2" DRAINVALVE

2" DRAIN/FILTER TOWASTE PIPING

NOTES:

1.) FOLLOW THE LISTED WESTECH REFERENCE DOCUMENTS EXCEPT AS NOTED ON THISDRAWING.

2.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST.ADDITIONAL PIPING, PIPE SUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDEDWITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTS TO BE INSTALLED AT THEJOBSITE BY THE INSTALLING CONTRACTOR.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTINGENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. SUPPORTS TO BE DESIGNED BY THE CONSULTINGENGINEER AND SUPPLIED BY THE INSTALLING CONTRACTOR. DO NOT SUPPORT PIPING OROTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

REFERENCE DOCUMENTSREV REVISION DESCRIPTION ECN DESIGNER APPROVER DATE

LOSS OF HEADINDICATOR

BACKWASH RATEOF FLOW INDICATOR

5'-6"TYP

8"

1'-934"

5'-434"

6'-512"

7'-618"

9'-71116"

0'-0"

5'-0"STRAIGHT

SIDEHEIGHT

1'-158"

8'-278"

PLAN

SECTION A-AEND

A A

REV

-SHEETDOCUMENT NUMBER

9001410000 1 OF 1

TITLE VERTICAL PRESSURE FILTERGENERAL ARRANGEMENT5'-0" DIAMETER, 5'-0" STRAIGHT SIDE, 3 TANK, WATERWASH

2014-10-21JA20BA91DESIGNER CHECKER APPROVER

THIS DRAWING IS PROPERTY OF WESTECH ENGINEERING, INC. AND IS TRANSMITTED IN CONFIDENCE. NEITHER RECEIPT NOR POSSESSION CONFERS OR TRANSFERS ANY RIGHTS TOREPRODUCE, USE, OR DISCLOSE, IN WHOLE OR IN PART, DATA CONTAINED HEREIN FOR ANY PURPOSE, WITHOUT THE WRITTEN PERMISSION OF WESTECH ENGINEERING, INC.

DATE

C:\vault\Design\Standard Products\General Filter\9000\900141 VPF 60X60\Waterwash 3 Tank Arrangement\Workgroup\IDW Files\9001410000-GA.idw

ADDITIONAL NOTES:

1.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST. ADDITIONAL PIPING, PIPESUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDED WITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTSTO BE INSTALLED AT JOBSITE, BY CUSTOMER.

2.) WHEN PRESSURE AERATION OCCURS BEFORE FILTRATION THERE NEEDS TO BE A PROVISION MADE FOR AIR RELEASE INTHE HIGHEST POINT OF THE INLETPIPING.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTING ENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. TO BE DESIGNED BY THE CONSULTING ENGINEER AND SUPPLIED BY THE INSTALLINGCONTRACTOR.

5.) DO NOT SUPPORT PIPING OR OTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

6.) MINIMUM RECOMMENDED CEILING HEIGHT: ALLOW 6" CLEARANCE ABOVE THE AIR RELEASE PIPING.

7.) BACKWASH WASTE SUMP SIZING AND LOCATION DESIGN IS BY THE CONSULTING ENGINEER. SUMP TO BE DESIGNED FORMAXIMUM DESIGN BACKWASH RATE.

15°TYP

5'-0" TYPOUTSIDE

3'-558"

4'-514"

3'-0"

3" INFLUENT PIPING(BY OTHERS)

4" EFFLUENT PIPING(BY OTHERS)

1'-714"

4"

14" X 18"MANWAY

0.75" AUTOMATICAIR RELEASE

PIPING3" INFLUENT/BACKWASHTANK CONNECTION

3" MANUAL BACKWASHRATE SET VALVE

2" INFLUENTVALVE

3" BACKWASHWASTE VALVE

3" EFFLUENTTANK CONNECTION

3" EFFLUENTVALVE

2" DRAINVALVE

2" DRAIN/FILTER TOWASTE PIPING

NOTES:

1.) FOLLOW THE LISTED WESTECH REFERENCE DOCUMENTS EXCEPT AS NOTED ON THISDRAWING.

2.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST.ADDITIONAL PIPING, PIPE SUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDEDWITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTS TO BE INSTALLED AT THEJOBSITE BY THE INSTALLING CONTRACTOR.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTINGENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. SUPPORTS TO BE DESIGNED BY THE CONSULTINGENGINEER AND SUPPLIED BY THE INSTALLING CONTRACTOR. DO NOT SUPPORT PIPING OROTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

REFERENCE DOCUMENTSREV REVISION DESCRIPTION ECN DESIGNER APPROVER DATE

LOSS OF HEADINDICATOR

BACKWASH RATEOF FLOW INDICATOR

6'-0"TYP

8"

1'-934"

5'-558"

6'-638"

7'-7"

9'-9 516"

0'-0"

5'-0"STRAIGHT

SIDEHEIGHT

1'-158"

8'-412"

PLAN

SECTION A-AEND

A A

REV

-SHEETDOCUMENT NUMBER

9001420000 1 OF 1

TITLE VERTICAL PRESSURE FILTERGENERAL ARRANGEMENT5'-6" DIAMETER, 5'-0" STRAIGHT SIDE, 3 TANK, WATERWASH

2014-10-21JA20BA91DESIGNER CHECKER APPROVER

THIS DRAWING IS PROPERTY OF WESTECH ENGINEERING, INC. AND IS TRANSMITTED IN CONFIDENCE. NEITHER RECEIPT NOR POSSESSION CONFERS OR TRANSFERS ANY RIGHTS TOREPRODUCE, USE, OR DISCLOSE, IN WHOLE OR IN PART, DATA CONTAINED HEREIN FOR ANY PURPOSE, WITHOUT THE WRITTEN PERMISSION OF WESTECH ENGINEERING, INC.

DATE

C:\vault\Design\Standard Products\General Filter\9000\900142 VPF 66X60\Waterwash 3 Tank Arrangement\Workgroup\IDW Files\9001420000-GA.idw

ADDITIONAL NOTES:

1.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST. ADDITIONAL PIPING, PIPESUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDED WITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTSTO BE INSTALLED AT JOBSITE, BY CUSTOMER.

2.) WHEN PRESSURE AERATION OCCURS BEFORE FILTRATION THERE NEEDS TO BE A PROVISION MADE FOR AIR RELEASE INTHE HIGHEST POINT OF THE INLETPIPING.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTING ENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. TO BE DESIGNED BY THE CONSULTING ENGINEER AND SUPPLIED BY THE INSTALLINGCONTRACTOR.

5.) DO NOT SUPPORT PIPING OR OTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

6.) MINIMUM RECOMMENDED CEILING HEIGHT: ALLOW 6" CLEARANCE ABOVE THE AIR RELEASE PIPING.

7.) BACKWASH WASTE SUMP SIZING AND LOCATION DESIGN IS BY THE CONSULTING ENGINEER. SUMP TO BE DESIGNED FORMAXIMUM DESIGN BACKWASH RATE.

15°TYP

5'-6" TYPOUTSIDE

3'-958"

4'-1078"

3'-3"

4" INFLUENT PIPING(BY OTHERS)

4" EFFLUENT PIPING(BY OTHERS)

1'-938"

4"

14" X 18"MANWAY

0.75" AUTOMATICAIR RELEASE

PIPING4" INFLUENT/BACKWASHTANK CONNECTION

4" MANUAL BACKWASHRATE SET VALVE

3" INFLUENTVALVE

4" BACKWASHWASTE VALVE

4" EFFLUENTTANK CONNECTION

4" EFFLUENTVALVE

3" DRAINVALVE

3" DRAIN/FILTER TOWASTE PIPING

NOTES:

1.) FOLLOW THE LISTED WESTECH REFERENCE DOCUMENTS EXCEPT AS NOTED ON THISDRAWING.

2.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST.ADDITIONAL PIPING, PIPE SUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDEDWITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTS TO BE INSTALLED AT THEJOBSITE BY THE INSTALLING CONTRACTOR.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTINGENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. SUPPORTS TO BE DESIGNED BY THE CONSULTINGENGINEER AND SUPPLIED BY THE INSTALLING CONTRACTOR. DO NOT SUPPORT PIPING OROTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

REFERENCE DOCUMENTSREV REVISION DESCRIPTION ECN DESIGNER APPROVER DATE

LOSS OF HEADINDICATOR

BACKWASH RATEOF FLOW INDICATOR

6'-6"TYP

8"

1'-11"

5'-538"

6'-838"

7'-1118"

10'-12"

0'-0"

5'-0"STRAIGHT

SIDEHEIGHT

1'-258"

8'-71116"

PLAN

SECTION A-AEND

A A

REV

-SHEETDOCUMENT NUMBER

9001430000 1 OF 1

TITLE VERTICAL PRESSURE FILTERGENERAL ARRANGEMENT6'-0" DIAMETER, 5'-0" STRAIGHT SIDE, 3 TANK, WATERWASH

2014-10-21JA20BA91DESIGNER CHECKER APPROVER

THIS DRAWING IS PROPERTY OF WESTECH ENGINEERING, INC. AND IS TRANSMITTED IN CONFIDENCE. NEITHER RECEIPT NOR POSSESSION CONFERS OR TRANSFERS ANY RIGHTS TOREPRODUCE, USE, OR DISCLOSE, IN WHOLE OR IN PART, DATA CONTAINED HEREIN FOR ANY PURPOSE, WITHOUT THE WRITTEN PERMISSION OF WESTECH ENGINEERING, INC.

DATE

C:\vault\Design\Standard Products\General Filter\9000\900143 VPF 72X60\Waterwash 3 Tank Arrangement\Workgroup\IDW Files\9001430000-GA.idw

ADDITIONAL NOTES:

1.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST. ADDITIONAL PIPING, PIPESUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDED WITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTSTO BE INSTALLED AT JOBSITE, BY CUSTOMER.

2.) WHEN PRESSURE AERATION OCCURS BEFORE FILTRATION THERE NEEDS TO BE A PROVISION MADE FOR AIR RELEASE INTHE HIGHEST POINT OF THE INLETPIPING.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTING ENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. TO BE DESIGNED BY THE CONSULTING ENGINEER AND SUPPLIED BY THE INSTALLINGCONTRACTOR.

5.) DO NOT SUPPORT PIPING OR OTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

6.) MINIMUM RECOMMENDED CEILING HEIGHT: ALLOW 6" CLEARANCE ABOVE THE AIR RELEASE PIPING.

7.) BACKWASH WASTE SUMP SIZING AND LOCATION DESIGN IS BY THE CONSULTING ENGINEER. SUMP TO BE DESIGNED FORMAXIMUM DESIGN BACKWASH RATE.

15°TYP

6'-0" TYPOUTSIDE

4'-58"

5'-178"

3'-6"

4" INFLUENT PIPING(BY OTHERS)

6" EFFLUENT PIPING(BY OTHERS)

1'-11"

5"

14" X 18"MANWAY

0.75" AUTOMATICAIR RELEASE

PIPING4" INFLUENT/BACKWASHTANK CONNECTION

4" MANUAL BACKWASHRATE SET VALVE

3" INFLUENTVALVE

4" BACKWASHWASTE VALVE

4" EFFLUENTTANK CONNECTION

4" EFFLUENTVALVE

3" DRAINVALVE

3" DRAIN/FILTER TOWASTE PIPING

NOTES:

1.) FOLLOW THE LISTED WESTECH REFERENCE DOCUMENTS EXCEPT AS NOTED ON THISDRAWING.

2.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST.ADDITIONAL PIPING, PIPE SUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDEDWITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTS TO BE INSTALLED AT THEJOBSITE BY THE INSTALLING CONTRACTOR.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTINGENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. SUPPORTS TO BE DESIGNED BY THE CONSULTINGENGINEER AND SUPPLIED BY THE INSTALLING CONTRACTOR. DO NOT SUPPORT PIPING OROTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

REFERENCE DOCUMENTSREV REVISION DESCRIPTION ECN DESIGNER APPROVER DATE

LOSS OF HEADINDICATOR

BACKWASH RATEOF FLOW INDICATOR

7'-0"TYP

8"

2'-12"

5'-658"

6'-958"

8'-38"

10'-234"

0'-0"

5'-0"STRAIGHT

SIDEHEIGHT

1'-258"

8'-978"

PLAN

SECTION A-AEND

A A

REV

-SHEETDOCUMENT NUMBER

9001440000 1 OF 1

TITLE VERTICAL PRESSURE FILTERGENERAL ARRANGEMENT6'-6" DIAMETER, 60" STRAIGHT SIDE, 3 TANK, WATERWASH

2014-10-21JA20BA91DESIGNER CHECKER APPROVER

THIS DRAWING IS PROPERTY OF WESTECH ENGINEERING, INC. AND IS TRANSMITTED IN CONFIDENCE. NEITHER RECEIPT NOR POSSESSION CONFERS OR TRANSFERS ANY RIGHTS TOREPRODUCE, USE, OR DISCLOSE, IN WHOLE OR IN PART, DATA CONTAINED HEREIN FOR ANY PURPOSE, WITHOUT THE WRITTEN PERMISSION OF WESTECH ENGINEERING, INC.

DATE

C:\vault\Design\Standard Products\General Filter\9000\900144 VPF 78X60\Waterwash 3 Tank Arrangement\Workgroup\IDW Files\9001440000-GA.idw

ADDITIONAL NOTES:

1.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST. ADDITIONAL PIPING, PIPESUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDED WITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTSTO BE INSTALLED AT JOBSITE, BY CUSTOMER.

2.) WHEN PRESSURE AERATION OCCURS BEFORE FILTRATION THERE NEEDS TO BE A PROVISION MADE FOR AIR RELEASE INTHE HIGHEST POINT OF THE INLETPIPING.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTING ENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. TO BE DESIGNED BY THE CONSULTING ENGINEER AND SUPPLIED BY THE INSTALLINGCONTRACTOR.

5.) DO NOT SUPPORT PIPING OR OTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

6.) MINIMUM RECOMMENDED CEILING HEIGHT: ALLOW 6" CLEARANCE ABOVE THE AIR RELEASE PIPING.

7.) BACKWASH WASTE SUMP SIZING AND LOCATION DESIGN IS BY THE CONSULTING ENGINEER. SUMP TO BE DESIGNED FORMAXIMUM DESIGN BACKWASH RATE.

15°TYP

6'-6" TYPOUTSIDE

4'-358"

5'-538"

3'-9"

4" INFLUENT PIPING(BY OTHERS)

6" EFFLUENT PIPING(BY OTHERS)

2'-118"

5"

14" X 18"MANWAY

0.75" AUTOMATICAIR RELEASE

PIPING4" INFLUENT/BACKWASHTANK CONNECTION

4" MANUAL BACKWASHRATE SET VALVE

3" INFLUENTVALVE

4" BACKWASHWASTE VALVE

4" EFFLUENTTANK CONNECTION

4" EFFLUENTVALVE

3" DRAINVALVE

3" DRAIN/FILTER TOWASTE PIPING

NOTES:

1.) FOLLOW THE LISTED WESTECH REFERENCE DOCUMENTS EXCEPT AS NOTED ON THISDRAWING.

2.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST.ADDITIONAL PIPING, PIPE SUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDEDWITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTS TO BE INSTALLED AT THEJOBSITE BY THE INSTALLING CONTRACTOR.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTINGENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. SUPPORTS TO BE DESIGNED BY THE CONSULTINGENGINEER AND SUPPLIED BY THE INSTALLING CONTRACTOR. DO NOT SUPPORT PIPING OROTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

REFERENCE DOCUMENTSREV REVISION DESCRIPTION ECN DESIGNER APPROVER DATE

LOSS OF HEADINDICATOR

BACKWASH RATEOF FLOW INDICATOR

7'-6"TYP

9"

2'-112"

5'-838"

6'-1138"

8'-218"

10'-5 516"

0'-0"

5'-0"STRAIGHT

SIDEHEIGHT

1'-358"

9'-12"

PLAN

SECTION A-AEND

A A

REV

-SHEETDOCUMENT NUMBER

9001450000 1 OF 1

TITLE VERTICAL PRESSURE FILTERGENERAL ARRANGEMENT7'-0" DIAMETER, 5'-0" STRAIGHT SIDE, 3 TANK, WATERWASH

2014-10-21JA20BA91DESIGNER CHECKER APPROVER

THIS DRAWING IS PROPERTY OF WESTECH ENGINEERING, INC. AND IS TRANSMITTED IN CONFIDENCE. NEITHER RECEIPT NOR POSSESSION CONFERS OR TRANSFERS ANY RIGHTS TOREPRODUCE, USE, OR DISCLOSE, IN WHOLE OR IN PART, DATA CONTAINED HEREIN FOR ANY PURPOSE, WITHOUT THE WRITTEN PERMISSION OF WESTECH ENGINEERING, INC.

DATE

C:\vault\Design\Standard Products\General Filter\9000\900145 VPF 84X60\Waterwash 3 Tank Arrangement\Workgroup\IDW Files\9001450000-GA.idw

ADDITIONAL NOTES:

1.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST. ADDITIONAL PIPING, PIPESUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDED WITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTSTO BE INSTALLED AT JOBSITE, BY CUSTOMER.

2.) WHEN PRESSURE AERATION OCCURS BEFORE FILTRATION THERE NEEDS TO BE A PROVISION MADE FOR AIR RELEASE INTHE HIGHEST POINT OF THE INLETPIPING.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTING ENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. TO BE DESIGNED BY THE CONSULTING ENGINEER AND SUPPLIED BY THE INSTALLINGCONTRACTOR.

5.) DO NOT SUPPORT PIPING OR OTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

6.) MINIMUM RECOMMENDED CEILING HEIGHT: ALLOW 6" CLEARANCE ABOVE THE AIR RELEASE PIPING.

7.) BACKWASH WASTE SUMP SIZING AND LOCATION DESIGN IS BY THE CONSULTING ENGINEER. SUMP TO BE DESIGNED FORMAXIMUM DESIGN BACKWASH RATE.

15°TYP

7'-0" TYPOUTSIDE

4'-818"

5'-1138"

4'-0"

6" INFLUENT PIPING(BY OTHERS)

6" EFFLUENT PIPING(BY OTHERS)

2'-314"

5"

14" X 18"MANWAY

0.75" AUTOMATICAIR RELEASE

PIPING6" INFLUENT/BACKWASHTANK CONNECTION

6" MANUAL BACKWASHRATE SET VALVE

3" INFLUENTVALVE

6" BACKWASHWASTE VALVE

6" EFFLUENTTANK CONNECTION

6" EFFLUENTVALVE

3" DRAINVALVE

3" DRAIN/FILTER TOWASTE PIPING

NOTES:

1.) FOLLOW THE LISTED WESTECH REFERENCE DOCUMENTS EXCEPT AS NOTED ON THISDRAWING.

2.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST.ADDITIONAL PIPING, PIPE SUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDEDWITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTS TO BE INSTALLED AT THEJOBSITE BY THE INSTALLING CONTRACTOR.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTINGENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. SUPPORTS TO BE DESIGNED BY THE CONSULTINGENGINEER AND SUPPLIED BY THE INSTALLING CONTRACTOR. DO NOT SUPPORT PIPING OROTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

REFERENCE DOCUMENTSREV REVISION DESCRIPTION ECN DESIGNER APPROVER DATE

LOSS OF HEADINDICATOR

BACKWASH RATEOF FLOW INDICATOR

8'-0"TYP

9"

2'-318"

5'-818"

7'-214"

8'-8"

10'-958"

0'-0"

5'-0"STRAIGHT

SIDEHEIGHT

1'-518"

9'-434"

PLAN

SECTION A-AEND

A A

REV

-SHEETDOCUMENT NUMBER

9001460000 1 OF 1

TITLE VERTICAL PRESSURE FILTERGENERAL ARRANGEMENT7'-6" DIAMETER, 60" STRAIGHT SIDE, 3 TANK, WATERWASH

2014-10-24JA20BA91DESIGNER CHECKER APPROVER

THIS DRAWING IS PROPERTY OF WESTECH ENGINEERING, INC. AND IS TRANSMITTED IN CONFIDENCE. NEITHER RECEIPT NOR POSSESSION CONFERS OR TRANSFERS ANY RIGHTS TOREPRODUCE, USE, OR DISCLOSE, IN WHOLE OR IN PART, DATA CONTAINED HEREIN FOR ANY PURPOSE, WITHOUT THE WRITTEN PERMISSION OF WESTECH ENGINEERING, INC.

DATE

C:\vault\Design\Standard Products\General Filter\9000\900146 VPF 90X60\Waterwash 3 Tank Arrangement\Workgroup\IDW Files\9001460000-GA.idw

ADDITIONAL NOTES:

1.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST. ADDITIONAL PIPING, PIPESUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDED WITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTSTO BE INSTALLED AT JOBSITE, BY CUSTOMER.

2.) WHEN PRESSURE AERATION OCCURS BEFORE FILTRATION THERE NEEDS TO BE A PROVISION MADE FOR AIR RELEASE INTHE HIGHEST POINT OF THE INLETPIPING.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTING ENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. TO BE DESIGNED BY THE CONSULTING ENGINEER AND SUPPLIED BY THE INSTALLINGCONTRACTOR.

5.) DO NOT SUPPORT PIPING OR OTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

6.) MINIMUM RECOMMENDED CEILING HEIGHT: ALLOW 6" CLEARANCE ABOVE THE AIR RELEASE PIPING.

7.) BACKWASH WASTE SUMP SIZING AND LOCATION DESIGN IS BY THE CONSULTING ENGINEER. SUMP TO BE DESIGNED FORMAXIMUM DESIGN BACKWASH RATE.

15°TYP

7'-6" TYPOUTSIDE

4'-1118"

6'-358"

4'-3"

6" INFLUENT PIPING(BY OTHERS)

6" EFFLUENT PIPING(BY OTHERS)

2'-538"

5"

14" X 18"MANWAY

0.75" AUTOMATICAIR RELEASE

PIPING6" INFLUENT/BACKWASHTANK CONNECTION

6" MANUAL BACKWASHRATE SET VALVE

4" INFLUENTVALVE

6" BACKWASHWASTE VALVE

6" EFFLUENTTANK CONNECTION

6" EFFLUENTVALVE

4" DRAINVALVE

4" DRAIN/FILTER TOWASTE PIPING

NOTES:

1.) FOLLOW THE LISTED WESTECH REFERENCE DOCUMENTS EXCEPT AS NOTED ON THISDRAWING.

2.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST.ADDITIONAL PIPING, PIPE SUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDEDWITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTS TO BE INSTALLED AT THEJOBSITE BY THE INSTALLING CONTRACTOR.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTINGENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. SUPPORTS TO BE DESIGNED BY THE CONSULTINGENGINEER AND SUPPLIED BY THE INSTALLING CONTRACTOR. DO NOT SUPPORT PIPING OROTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

REFERENCE DOCUMENTSREV REVISION DESCRIPTION ECN DESIGNER APPROVER DATE

LOSS OF HEADINDICATOR

BACKWASH RATEOF FLOW INDICATOR

8'-6"TYP

10"

2'-418"

5'-10"

7'-418"

8'-1018"

11'-14"

0'-0"

5'-0"STRAIGHT

SIDEHEIGHT

1'-618"

9'-738"

PLAN

SECTION A-AEND

A A

REV

-SHEETDOCUMENT NUMBER

9001470000 1 OF 1

TITLE VERTICAL PRESSURE FILTERGENERAL ARRANGEMENT8'-0" DIAMETER, 5'-0" STRAIGHT SIDE, 3 TANK, WATERWASH

2014-10-21JA20BA91DESIGNER CHECKER APPROVER

THIS DRAWING IS PROPERTY OF WESTECH ENGINEERING, INC. AND IS TRANSMITTED IN CONFIDENCE. NEITHER RECEIPT NOR POSSESSION CONFERS OR TRANSFERS ANY RIGHTS TOREPRODUCE, USE, OR DISCLOSE, IN WHOLE OR IN PART, DATA CONTAINED HEREIN FOR ANY PURPOSE, WITHOUT THE WRITTEN PERMISSION OF WESTECH ENGINEERING, INC.

DATE

C:\vault\Design\Standard Products\General Filter\9000\900147 VPF 96X60\Waterwash 3 Tank Arrangement\Workgroup\IDW Files\9001470000-GA.idw

ADDITIONAL NOTES:

1.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST. ADDITIONAL PIPING, PIPESUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDED WITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTSTO BE INSTALLED AT JOBSITE, BY CUSTOMER.

2.) WHEN PRESSURE AERATION OCCURS BEFORE FILTRATION THERE NEEDS TO BE A PROVISION MADE FOR AIR RELEASE INTHE HIGHEST POINT OF THE INLETPIPING.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTING ENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. TO BE DESIGNED BY THE CONSULTING ENGINEER AND SUPPLIED BY THE INSTALLINGCONTRACTOR.

5.) DO NOT SUPPORT PIPING OR OTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

6.) MINIMUM RECOMMENDED CEILING HEIGHT: ALLOW 6" CLEARANCE ABOVE THE AIR RELEASE PIPING.

7.) BACKWASH WASTE SUMP SIZING AND LOCATION DESIGN IS BY THE CONSULTING ENGINEER. SUMP TO BE DESIGNED FORMAXIMUM DESIGN BACKWASH RATE.

15°TYP

8'-0" TYPOUTSIDE

5'-218"

6'-658"

4'-6"

6" INFLUENT PIPING(BY OTHERS)

6" EFFLUENT PIPING(BY OTHERS)

2'-712"

5"

14" X 18"MANWAY

0.75" AUTOMATICAIR RELEASE

PIPING6" INFLUENT/BACKWASHTANK CONNECTION

6" MANUAL BACKWASHRATE SET VALVE

4" INFLUENTVALVE

6" BACKWASHWASTE VALVE

6" EFFLUENTTANK CONNECTION

6" EFFLUENTVALVE

4" DRAINVALVE

4" DRAIN/FILTER TOWASTE PIPING

NOTES:

1.) FOLLOW THE LISTED WESTECH REFERENCE DOCUMENTS EXCEPT AS NOTED ON THISDRAWING.

2.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST.ADDITIONAL PIPING, PIPE SUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDEDWITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTS TO BE INSTALLED AT THEJOBSITE BY THE INSTALLING CONTRACTOR.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTINGENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. SUPPORTS TO BE DESIGNED BY THE CONSULTINGENGINEER AND SUPPLIED BY THE INSTALLING CONTRACTOR. DO NOT SUPPORT PIPING OROTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

REFERENCE DOCUMENTSREV REVISION DESCRIPTION ECN DESIGNER APPROVER DATE

LOSS OF HEADINDICATOR

BACKWASH RATEOF FLOW INDICATOR

9'-0"

10"

2'-418"

5'-1114"

7'-538"

8'-1138"

11'-234"

0'-0"

5'-0"STRAIGHT

SIDEHEIGHT

1'-618"

9'-978"

PLAN

SECTION A-AEND

A A

REV

-SHEETDOCUMENT NUMBER

9001480000 1 OF 1

TITLE VERTICAL PRESSURE FILTERGENERAL ARRANGEMENT8'-6" DIAMETER, 60" STRAIGHT SIDE, 3 TANK, WATERWASH

2014-10-27JA20BA91DESIGNER CHECKER APPROVER

THIS DRAWING IS PROPERTY OF WESTECH ENGINEERING, INC. AND IS TRANSMITTED IN CONFIDENCE. NEITHER RECEIPT NOR POSSESSION CONFERS OR TRANSFERS ANY RIGHTS TOREPRODUCE, USE, OR DISCLOSE, IN WHOLE OR IN PART, DATA CONTAINED HEREIN FOR ANY PURPOSE, WITHOUT THE WRITTEN PERMISSION OF WESTECH ENGINEERING, INC.

DATE

C:\vault\Design\Standard Products\General Filter\9000\900148 VPF 102X60\Waterwash 3 Tank Arrangement\Workgroup\IDW Files\9001480000-GA.idw

ADDITIONAL NOTES:

1.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST. ADDITIONAL PIPING, PIPESUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDED WITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTSTO BE INSTALLED AT JOBSITE, BY CUSTOMER.

2.) WHEN PRESSURE AERATION OCCURS BEFORE FILTRATION THERE NEEDS TO BE A PROVISION MADE FOR AIR RELEASE INTHE HIGHEST POINT OF THE INLETPIPING.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTING ENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. TO BE DESIGNED BY THE CONSULTING ENGINEER AND SUPPLIED BY THE INSTALLINGCONTRACTOR.

5.) DO NOT SUPPORT PIPING OR OTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

6.) MINIMUM RECOMMENDED CEILING HEIGHT: ALLOW 6" CLEARANCE ABOVE THE AIR RELEASE PIPING.

7.) BACKWASH WASTE SUMP SIZING AND LOCATION DESIGN IS BY THE CONSULTING ENGINEER. SUMP TO BE DESIGNED FORMAXIMUM DESIGN BACKWASH RATE.

15°TYP

8'-6" TYPOUTSIDE

5'-518"

6'-958"

4'-9"

6" INFLUENT PIPING(BY OTHERS)

6" EFFLUENT PIPING(BY OTHERS)

2'-712"

9"

14" X 18"MANWAY

0.75" AUTOMATICAIR RELEASE

PIPING6" INFLUENT/BACKWASHTANK CONNECTION

6" MANUAL BACKWASHRATE SET VALVE

4" INFLUENTVALVE

6" BACKWASHWASTE VALVE

6" EFFLUENTTANK CONNECTION

6" EFFLUENTVALVE

4" DRAINVALVE

4" DRAIN/FILTER TOWASTE PIPING

NOTES:

1.) FOLLOW THE LISTED WESTECH REFERENCE DOCUMENTS EXCEPT AS NOTED ON THISDRAWING.

2.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST.ADDITIONAL PIPING, PIPE SUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDEDWITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTS TO BE INSTALLED AT THEJOBSITE BY THE INSTALLING CONTRACTOR.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTINGENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. SUPPORTS TO BE DESIGNED BY THE CONSULTINGENGINEER AND SUPPLIED BY THE INSTALLING CONTRACTOR. DO NOT SUPPORT PIPING OROTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

REFERENCE DOCUMENTSREV REVISION DESCRIPTION ECN DESIGNER APPROVER DATE

LOSS OF HEADINDICATOR

BACKWASH RATEOF FLOW INDICATOR

9'-6"TYP

10"

2'-418"

6'-18"

7'-614"

9'-14"

11'-4 716"

0'-0"

5'-0"STRAIGHT

SIDEHEIGHT

1'-618"

9'-1112"

PLAN

SECTION A-AEND

A A

REV

-SHEETDOCUMENT NUMBER

9001490000 1 OF 1

TITLE VERTICAL PRESSURE FILTERGENERAL ARRANGEMENT9'-0" DIAMETER, 60" STRAIGHT SIDE, 3 TANK, WATERWASH

2014-10-27JA20BA91DESIGNER CHECKER APPROVER

THIS DRAWING IS PROPERTY OF WESTECH ENGINEERING, INC. AND IS TRANSMITTED IN CONFIDENCE. NEITHER RECEIPT NOR POSSESSION CONFERS OR TRANSFERS ANY RIGHTS TOREPRODUCE, USE, OR DISCLOSE, IN WHOLE OR IN PART, DATA CONTAINED HEREIN FOR ANY PURPOSE, WITHOUT THE WRITTEN PERMISSION OF WESTECH ENGINEERING, INC.

DATE

C:\vault\Design\Standard Products\General Filter\9000\900149 VPF 108X60\Waterwash 3 Tank Arrangement\Workgroup\IDW Files\9001490000-GA.idw

ADDITIONAL NOTES:

1.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST. ADDITIONAL PIPING, PIPESUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDED WITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTSTO BE INSTALLED AT JOBSITE, BY CUSTOMER.

2.) WHEN PRESSURE AERATION OCCURS BEFORE FILTRATION THERE NEEDS TO BE A PROVISION MADE FOR AIR RELEASE INTHE HIGHEST POINT OF THE INLETPIPING.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTING ENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. TO BE DESIGNED BY THE CONSULTING ENGINEER AND SUPPLIED BY THE INSTALLINGCONTRACTOR.

5.) DO NOT SUPPORT PIPING OR OTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

6.) MINIMUM RECOMMENDED CEILING HEIGHT: ALLOW 6" CLEARANCE ABOVE THE AIR RELEASE PIPING.

7.) BACKWASH WASTE SUMP SIZING AND LOCATION DESIGN IS BY THE CONSULTING ENGINEER. SUMP TO BE DESIGNED FORMAXIMUM DESIGN BACKWASH RATE.

15°TYP

9'-0" TYPOUTSIDE

5'-818"

7'-58"

5'-0"

6" INFLUENT PIPING(BY OTHERS)

8" EFFLUENT PIPING(BY OTHERS)

2'-958"

9"

14" X 18"MANWAY

0.75" AUTOMATICAIR RELEASE

PIPING6" INFLUENT/BACKWASHTANK CONNECTION

6" MANUAL BACKWASHRATE SET VALVE

4" INFLUENTVALVE

6" BACKWASHWASTE VALVE

6" EFFLUENTTANK CONNECTION

6" EFFLUENTVALVE

4" DRAINVALVE

4" DRAIN/FILTER TOWASTE PIPING

NOTES:

1.) FOLLOW THE LISTED WESTECH REFERENCE DOCUMENTS EXCEPT AS NOTED ON THISDRAWING.

2.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST.ADDITIONAL PIPING, PIPE SUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDEDWITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTS TO BE INSTALLED AT THEJOBSITE BY THE INSTALLING CONTRACTOR.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTINGENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. SUPPORTS TO BE DESIGNED BY THE CONSULTINGENGINEER AND SUPPLIED BY THE INSTALLING CONTRACTOR. DO NOT SUPPORT PIPING OROTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

REFERENCE DOCUMENTSREV REVISION DESCRIPTION ECN DESIGNER APPROVER DATE

LOSS OF HEADINDICATOR

BACKWASH RATEOF FLOW INDICATOR

10'-0"TYP

10"

2'-518"

6'-78"

7'-7"

9'-1"

11'-6 116"

0'-0"

5'-0"STRAIGHT

SIDEHEIGHT

1'-618"

10'-118"

PLAN

SECTION A-AEND

A A

REV

-SHEETDOCUMENT NUMBER

9001500000 1 OF 1

TITLE VERTICAL PRESSURE FILTERGENERAL ARRANGEMENT9'-6" DIAMETER, 60" STRAIGHT SIDE, 3 TANK, WATERWASH

2014-10-27JA20BA91DESIGNER CHECKER APPROVER

THIS DRAWING IS PROPERTY OF WESTECH ENGINEERING, INC. AND IS TRANSMITTED IN CONFIDENCE. NEITHER RECEIPT NOR POSSESSION CONFERS OR TRANSFERS ANY RIGHTS TOREPRODUCE, USE, OR DISCLOSE, IN WHOLE OR IN PART, DATA CONTAINED HEREIN FOR ANY PURPOSE, WITHOUT THE WRITTEN PERMISSION OF WESTECH ENGINEERING, INC.

DATE

C:\vault\Design\Standard Products\General Filter\9000\900150 VPF 114X60\Waterwash 3 Tank Arrangement\Workgroup\IDW Files\9001500000-GA.idw

ADDITIONAL NOTES:

1.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST. ADDITIONAL PIPING, PIPESUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDED WITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTSTO BE INSTALLED AT JOBSITE, BY CUSTOMER.

2.) WHEN PRESSURE AERATION OCCURS BEFORE FILTRATION THERE NEEDS TO BE A PROVISION MADE FOR AIR RELEASE INTHE HIGHEST POINT OF THE INLETPIPING.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTING ENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. TO BE DESIGNED BY THE CONSULTING ENGINEER AND SUPPLIED BY THE INSTALLINGCONTRACTOR.

5.) DO NOT SUPPORT PIPING OR OTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

6.) MINIMUM RECOMMENDED CEILING HEIGHT: ALLOW 6" CLEARANCE ABOVE THE AIR RELEASE PIPING.

7.) BACKWASH WASTE SUMP SIZING AND LOCATION DESIGN IS BY THE CONSULTING ENGINEER. SUMP TO BE DESIGNED FORMAXIMUM DESIGN BACKWASH RATE.

15°TYP

9'-6" TYPOUTSIDE

5'-1118"

7'-358"

5'-3"

6" INFLUENT PIPING(BY OTHERS)

8" EFFLUENT PIPING(BY OTHERS)

2'-1134"

9"

14" X 18"MANWAY

0.75" AUTOMATICAIR RELEASE

PIPING6" INFLUENT/BACKWASHTANK CONNECTION

6" MANUAL BACKWASHRATE SET VALVE

4" INFLUENTVALVE

6" BACKWASHWASTE VALVE

6" EFFLUENTTANK CONNECTION

6" EFFLUENTVALVE

4" DRAINVALVE

4" DRAIN/FILTER TOWASTE PIPING

NOTES:

1.) FOLLOW THE LISTED WESTECH REFERENCE DOCUMENTS EXCEPT AS NOTED ON THISDRAWING.

2.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST.ADDITIONAL PIPING, PIPE SUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDEDWITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTS TO BE INSTALLED AT THEJOBSITE BY THE INSTALLING CONTRACTOR.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTINGENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. SUPPORTS TO BE DESIGNED BY THE CONSULTINGENGINEER AND SUPPLIED BY THE INSTALLING CONTRACTOR. DO NOT SUPPORT PIPING OROTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

REFERENCE DOCUMENTSREV REVISION DESCRIPTION ECN DESIGNER APPROVER DATE

LOSS OF HEADINDICATOR

BACKWASH RATEOF FLOW INDICATOR

10'-6"TYP

10"

2'-518"

6'-218"

7'-814"

9'-214"

11'-8 916"

0'-0"

5'-0"STRAIGHT

SIDEHEIGHT

1'-618"

10'-358"

PLAN

SECTION A-AEND

A A

REV

-SHEETDOCUMENT NUMBER

9001510000 1 OF 1

TITLE VERTICAL PRESSURE FILTERGENERAL ARRANGEMENT10'-0" DIAMETER, 5'-0" STRAIGHT SIDE, 3 TANK, WATERWASH

2014-10-21JA20BA91DESIGNER CHECKER APPROVER

THIS DRAWING IS PROPERTY OF WESTECH ENGINEERING, INC. AND IS TRANSMITTED IN CONFIDENCE. NEITHER RECEIPT NOR POSSESSION CONFERS OR TRANSFERS ANY RIGHTS TOREPRODUCE, USE, OR DISCLOSE, IN WHOLE OR IN PART, DATA CONTAINED HEREIN FOR ANY PURPOSE, WITHOUT THE WRITTEN PERMISSION OF WESTECH ENGINEERING, INC.

DATE

C:\vault\Design\Standard Products\General Filter\9000\900151 VPF 120X60\Waterwash 3 Tank Arrangement\Workgroup\IDW Files\9001510000-GA.idw

ADDITIONAL NOTES:

1.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST. ADDITIONAL PIPING, PIPESUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDED WITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTSTO BE INSTALLED AT JOBSITE, BY CUSTOMER.

2.) WHEN PRESSURE AERATION OCCURS BEFORE FILTRATION THERE NEEDS TO BE A PROVISION MADE FOR AIR RELEASE INTHE HIGHEST POINT OF THE INLETPIPING.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTING ENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. TO BE DESIGNED BY THE CONSULTING ENGINEER AND SUPPLIED BY THE INSTALLINGCONTRACTOR.

5.) DO NOT SUPPORT PIPING OR OTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

6.) MINIMUM RECOMMENDED CEILING HEIGHT: ALLOW 6" CLEARANCE ABOVE THE AIR RELEASE PIPING.

7.) BACKWASH WASTE SUMP SIZING AND LOCATION DESIGN IS BY THE CONSULTING ENGINEER. SUMP TO BE DESIGNED FORMAXIMUM DESIGN BACKWASH RATE.

15°TYP

10'-0" TYPOUTSIDE

6'-218"

7'-814"

5'-6"

8" INFLUENT PIPING(BY OTHERS)

8" EFFLUENT PIPING(BY OTHERS)

3'-178"

9"

14" X 18"MANWAY

0.75" AUTOMATICAIR RELEASE

PIPING6" INFLUENT/BACKWASHTANK CONNECTION

6" MANUAL BACKWASHRATE SET VALVE

6" INFLUENTVALVE

6" BACKWASHWASTE VALVE

6" EFFLUENTTANK CONNECTION

6" EFFLUENTVALVE

6" DRAINVALVE

6" DRAIN/FILTER TOWASTE PIPING

NOTES:

1.) FOLLOW THE LISTED WESTECH REFERENCE DOCUMENTS EXCEPT AS NOTED ON THISDRAWING.

2.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST.ADDITIONAL PIPING, PIPE SUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDEDWITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTS TO BE INSTALLED AT THEJOBSITE BY THE INSTALLING CONTRACTOR.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTINGENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. SUPPORTS TO BE DESIGNED BY THE CONSULTINGENGINEER AND SUPPLIED BY THE INSTALLING CONTRACTOR. DO NOT SUPPORT PIPING OROTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

REFERENCE DOCUMENTSREV REVISION DESCRIPTION ECN DESIGNER APPROVER DATE

LOSS OF HEADINDICATOR

BACKWASH RATEOF FLOW INDICATOR

11'-0"TYP

11"

2'-618"

6'-378"

7'-10"

9'-518"

11'-1118"

0'-0"

5'-0"STRAIGHT

SIDEHEIGHT

1'-718"

10'-6 316"

PLAN

SECTION A-AEND

A A

REV

-SHEETDOCUMENT NUMBER

9001520000 1 OF 1

TITLE VERTICAL PRESSURE FILTERGENERAL ARRANGEMENT11'-0" DIAMETER, 60" STRAIGHT SIDE, 3 TANK, WATERWASH

2014-10-28JA20BA91DESIGNER CHECKER APPROVER

THIS DRAWING IS PROPERTY OF WESTECH ENGINEERING, INC. AND IS TRANSMITTED IN CONFIDENCE. NEITHER RECEIPT NOR POSSESSION CONFERS OR TRANSFERS ANY RIGHTS TOREPRODUCE, USE, OR DISCLOSE, IN WHOLE OR IN PART, DATA CONTAINED HEREIN FOR ANY PURPOSE, WITHOUT THE WRITTEN PERMISSION OF WESTECH ENGINEERING, INC.

DATE

C:\vault\Design\Standard Products\General Filter\9000\900152 VPF 132X60\Waterwash 3 Tank Arrangement\Workgroup\IDW Files\9001520000-GA.idw

ADDITIONAL NOTES:

1.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST. ADDITIONAL PIPING, PIPESUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDED WITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTSTO BE INSTALLED AT JOBSITE, BY CUSTOMER.

2.) WHEN PRESSURE AERATION OCCURS BEFORE FILTRATION THERE NEEDS TO BE A PROVISION MADE FOR AIR RELEASE INTHE HIGHEST POINT OF THE INLETPIPING.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTING ENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. TO BE DESIGNED BY THE CONSULTING ENGINEER AND SUPPLIED BY THE INSTALLINGCONTRACTOR.

5.) DO NOT SUPPORT PIPING OR OTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

6.) MINIMUM RECOMMENDED CEILING HEIGHT: ALLOW 6" CLEARANCE ABOVE THE AIR RELEASE PIPING.

7.) BACKWASH WASTE SUMP SIZING AND LOCATION DESIGN IS BY THE CONSULTING ENGINEER. SUMP TO BE DESIGNED FORMAXIMUM DESIGN BACKWASH RATE.

15°TYP

11'-0" TYPOUTSIDE

6'-918"

8'-414"

6'-0"

8" INFLUENT PIPING(BY OTHERS)

8" EFFLUENT PIPING(BY OTHERS)

3'-6 316"

9"

14" X 18"MANWAY

0.75" AUTOMATICAIR RELEASE

PIPING

8" INFLUENT/BACKWASHTANK CONNECTION

8" MANUAL BACKWASHRATE SET VALVE

6" INFLUENTVALVE

8" BACKWASHWASTE VALVE

8" EFFLUENTTANK CONNECTION

8" EFFLUENTVALVE

6" DRAINVALVE

6" DRAIN/FILTER TOWASTE PIPING

NOTES:

1.) FOLLOW THE LISTED WESTECH REFERENCE DOCUMENTS EXCEPT AS NOTED ON THISDRAWING.

2.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST.ADDITIONAL PIPING, PIPE SUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDEDWITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTS TO BE INSTALLED AT THEJOBSITE BY THE INSTALLING CONTRACTOR.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTINGENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. SUPPORTS TO BE DESIGNED BY THE CONSULTINGENGINEER AND SUPPLIED BY THE INSTALLING CONTRACTOR. DO NOT SUPPORT PIPING OROTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

REFERENCE DOCUMENTSREV REVISION DESCRIPTION ECN DESIGNER APPROVER DATE

LOSS OF HEADINDICATOR

BACKWASH RATEOF FLOW INDICATOR

12'-0"TYP

11"

2'-712"

6'-458"

8'-118"

9'-914"

12'-438"

0'-0"

5'-0"STRAIGHT

SIDEHEIGHT

1'-818"

10'-1138"

PLAN

SECTION A-AEND

A A

REV

-SHEETDOCUMENT NUMBER

9001530000 1 OF 1

TITLE VERTICAL PRESSURE FILTERGENERAL ARRANGEMENT12'-0" DIAMETER, 5'-0" STRAIGHT SIDE, 3 TANK, WATERWASH

2014-10-21JA20BA91DESIGNER CHECKER APPROVER

THIS DRAWING IS PROPERTY OF WESTECH ENGINEERING, INC. AND IS TRANSMITTED IN CONFIDENCE. NEITHER RECEIPT NOR POSSESSION CONFERS OR TRANSFERS ANY RIGHTS TOREPRODUCE, USE, OR DISCLOSE, IN WHOLE OR IN PART, DATA CONTAINED HEREIN FOR ANY PURPOSE, WITHOUT THE WRITTEN PERMISSION OF WESTECH ENGINEERING, INC.

DATE

C:\vault\Design\Standard Products\General Filter\9000\900153 VPF 144X60\Waterwash 3 Tank Arrangement\Workgroup\IDW Files\9001530000-GA.idw

ADDITIONAL NOTES:

1.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST. ADDITIONAL PIPING, PIPESUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDED WITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTSTO BE INSTALLED AT JOBSITE, BY CUSTOMER.

2.) WHEN PRESSURE AERATION OCCURS BEFORE FILTRATION THERE NEEDS TO BE A PROVISION MADE FOR AIR RELEASE INTHE HIGHEST POINT OF THE INLETPIPING.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTING ENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. TO BE DESIGNED BY THE CONSULTING ENGINEER AND SUPPLIED BY THE INSTALLINGCONTRACTOR.

5.) DO NOT SUPPORT PIPING OR OTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

6.) MINIMUM RECOMMENDED CEILING HEIGHT: ALLOW 6" CLEARANCE ABOVE THE AIR RELEASE PIPING.

7.) BACKWASH WASTE SUMP SIZING AND LOCATION DESIGN IS BY THE CONSULTING ENGINEER. SUMP TO BE DESIGNED FORMAXIMUM DESIGN BACKWASH RATE.

15°TYP

12'-0" TYPOUTSIDE

7'-318"

8'-1014"

6'-6"

8" INFLUENT PIPING(BY OTHERS)

10" EFFLUENT PIPING(BY OTHERS)

3'-10 716"

9"

14" X 18"MANWAY

0.75" AUTOMATICAIR RELEASE

PIPING8" INFLUENT/BACKWASHTANK CONNECTION

8" MANUAL BACKWASHRATE SET VALVE

6" INFLUENTVALVE

8" BACKWASHWASTE VALVE

8" EFFLUENTTANK CONNECTION

8" EFFLUENTVALVE

6" DRAINVALVE

6" DRAIN/FILTER TOWASTE PIPING

NOTES:

1.) FOLLOW THE LISTED WESTECH REFERENCE DOCUMENTS EXCEPT AS NOTED ON THISDRAWING.

2.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST.ADDITIONAL PIPING, PIPE SUPPORTS, AND CONNECTION FITTINGS ARE NOT INCLUDEDWITH STANDARD UNIT. MAJOR EQUIPMENT AND COMPONENTS TO BE INSTALLED AT THEJOBSITE BY THE INSTALLING CONTRACTOR.

3.) EQUIPMENT CONCRETE DESIGN IS THE RESPONSIBILITY OF THE CONSULTINGENGINEER.

4.) PIPE SUPPORTS ARE NOT SHOWN. SUPPORTS TO BE DESIGNED BY THE CONSULTINGENGINEER AND SUPPLIED BY THE INSTALLING CONTRACTOR. DO NOT SUPPORT PIPING OROTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

REFERENCE DOCUMENTSREV REVISION DESCRIPTION ECN DESIGNER APPROVER DATE

LOSS OF HEADINDICATOR

BACKWASH RATEOF FLOW INDICATOR

13'-0"

11"

2'-912"

6'-658"

8'-318"

9'-1114"

12'-8 716"

0'-0"

5'-0"STRAIGHT

SIDEHEIGHT

1'-818"

11'-3 716"