    NSDB Circuit Inventory Gateway1.000 Release Highlights

    The NSDB Circuit Inventory Gateway provides REACT with the capability to interface with the NSDBsystem over TCIS/TOPCOM. The following enhancements have been included in this release:

    Provided support for multiple installations on the same platform to connect to more than

    one NSDB system (one-to-one relationship between the instance of the interface and theNSDB system)

    Increased buffer size for multipoint circuits

    Provided a cron job to restart the NSDB server and FCIF parser as needed

    Added a REACT config.sys option HNIS_CKTS which specifies whether the circuit accesscode (CAC) or circuit layout order (CLO) request types are supported

    Added REACT config.sys options to enable the database server timeout to be independentfrom all other timeouts in REACT

    - DB_SERVER_COMM_TO_HDI_TIMEOUT(Sets database server communication toHekimian Database Interface [HDI])

    - GUI_COMM_TO_DB_SERVER_TIMEOUT(Sets GUI communication to the database server)

    NOTE: The GUI_COMM_TO_DB_TIMEOUTcannot be less than theDB_SERVER_COMM_TO_HDI_TIMEOUT .

    Additionally, the HDI Multiplexer Module Release 1.000 can be used with the NSDB Circuit InventoryGateway to fetch circuits from multiple NSDB systems from a single instance of the interface. Withthis module, REACT sends a circuit request through the HDI Multiplexer, which is configured to

    broadcast the circuit request to multiple NSDB systems. If only one circuit is returned, the circuit isdisplayed in the REACT GUI. If multiple circuits are returned, the circuit that matches the requestedcircuit ID is displayed in the REACT GUI.

    PIR 274

  • 8/10/2019 PIR1274.pdf

    2/2

    NSDB Circuit Inventory Gateway Data Flow

    For further information on NSDB Circuit Inventory Gateway 1.000, contact your account manageror call Client Services at 1-301-590-3500 or 1-800-321-0780.

    2002 Spirent Communications of Rockville, Inc. All of the company names and/or brands and/or product names referred to in

    this document, in particular the name "Spirent" and its logo device are either registered trademarks or trademarks pending

    registration in accordance with relevant national laws. All rights reserved. Specifications subject to change without notice.

    4. The TCIS serverretrieves the circuit

    in FCIF format fromthe NSDB source.

    5. The TCIS server sendsthe data to the NSDB

    Gateway Server.

    8. The HDI circuit

    message isreturned to the

    requesting OSS.

    3. The request is forwarded tothe NSDB gateway server,

    which sends the request tothe TCIS server via TOPCOM.

    1. Spirents OSS

    requests a circuit.

    2. The HDI circuit

    request is sent tothe FCIF Parser.

    6. The circuit data is forwarded

    to the FCIF Parser.

    7. The FCIF Parser receives thecircuit data and generates a

    circuit message in HDI format

    15200 Omega Drive Rockville, MD 20850-3240

    Toll-free: 877.oss.test Tel: 301.590.3600 Fax: 301.590.3698

    www.spirentcom.com [email protected] 0202