pin braze, cadweld

3
(FOTO) (FOTO) (FOTO) (FOTO) (FOTO) (FOTO) PIN BRAZE, CADWELD 41 Bevel the edges of the plant coating surrounding the Pinbraze. Roughen the surface of the plant coating surrounding the Pinbraze with an abrasive pad or sand paper. Remove all contaminations. Degrease with isopropyl alcohol. Do not use a thinner. 128 20-04-2020 1 2 3 4 5 6 APPLICATION MANUAL 2020

Upload: others

Post on 05-Dec-2021

15 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PIN BRAZE, CADWELD

(FOTO) (FOTO)

(FOTO) (FOTO)

(FOTO) (FOTO)

PIN BRAZE, CADWELD 41

Bevel the edges of the plant coating surrounding the Pinbraze.

Roughen the surface of the plant coating surrounding the Pinbraze with an abrasive pad or sand paper. Remove all contaminations.

Degrease with isopropyl alcohol. Do not use a thinner.

12820-04-2020

1 2

3 4

5 6

APPLICATION MANUAL 2020

Page 2: PIN BRAZE, CADWELD

(FOTO) (FOTO)

(FOTO) (FOTO)

(FOTO) (FOTO)

41

Apply preheated Paste around the Pinbraze and underneath the connecting wire. Check the adhesion of the paste

Fill the area around the Pinbraze with preheated Paste. Avoid air inclusions.

Pre cut a patch of Wrappingband according to the above drawing and place it over the Paste.

12920-04-2020

7 8

9 10

11 12

APPLICATION MANUAL 2020

PIN BRAZE, CADWELD

Page 3: PIN BRAZE, CADWELD

(FOTO) (FOTO)

(FOTO) (FOTO)

(FOTO) (FOTO)

41

A holiday test using a high voltage tester must be carried out on the green Stopaq Wrappingband prior to the application of any Outerwrap. The test must be carried out at a minimum of 15kV.

Always use approved and certified holiday test equipment.

Apply Outerwrap HTPP with tension over the Wrappingband and avoid air inclusions. Start and finish with an overlap of at least 50mm on plant coating adjacent to the Wrappingband.

13020-04-2020

13

15 16

APPLICATION MANUAL 2020

Use strips of Wrappingband to place the CP cable with loops on the surface.

1817

14

PIN BRAZE, CADWELD