Pilot Operated Directional Valves
Catalog
DG3V-8; 700 l/min (185USgpm) 350 bar (5000 psi)
DG5V-8; 700 l/min (185USgpm) 350 bar (5000 psi)
NFPA D08, ISO-4401-08,CETOP 8
2 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
Introduction
General Description
The Size 8 Directiona ControlValve serves as a controlvalve package. It offers direc-tional control, pilot pressurereducers, pilot chokes, andmain stage stroke adjust-ment to control the flow.
The valves are generallyused to control large flowsup to 700 l/min (185 USgpm)at 350 bar (5000 psi) and pro-vide low pressure drops. Therange includes:
• DG3V-8 - remote pilotoperated valve.
• DG5V-8-S - DG4V-3S-60standard performance D03pilot valve 100 bar (1450psi) tank line rating.
• DG5V-8-H - DG4V-3-60high performance D03pilot valve 210 bar (3000psi) tank line rating.
Each valve contains a main-stage spool which is posi-tioned in the valve by specialarrangement. The fourarrangements are:
• Spring offset - For singlestage operation, onespring returns spool to anoffset position. Fortwo–stage operation,springs and washers areremoved from main stageand offset action isobtained from pilot valve.
• Spring centered - Springand washer are located onboth ends of main stagespool to control centering.
• Pressure centered -Centering springs areused in addition to pilotpressure, to provide posi-tive centering should pilotpressure fail.
• No–spring detented -Springs and washers areprovided so that in theevent of pilot pressure fail-ure, the main spool willspring center.
Features and Benefits
• A ‘‘mini-system’’ capabilitywith wide variety of spooland spring arrangements,stroke and pilot chokeadjustments, integralcheck valves and port ori-fices.
• High force solenoids andcentering springs assureconsistent shiftingthrough a wide range ofpressure and siltingextremes.
• Optional MainstageSpool PositionMonitoring Switch (CE marked)
• Suitable for demandingindustrial or mobile appli-cations by providing forreliable operations.
• Endurance tested to 10million cycles and fatiguetested without failure toensure highest reliability.
• Fatigue testing performedto NFPA specifications toensure the highest reliabili-ty in applications requiringhigh flows and pressure.
• Solid cast body and coredpassages for maximumstrength and minimal pres-sure drop.
• Electrical options includingcoil types, connections,and wiring housings allowfull compatibility and reli-able performance in anysystem application.
• Plain, waterproof, and lock-able manual overrideoptions are available tofacilitate system trou-bleshooting or servicing.
• The DG3V and DG5V are100% interchangeablewith previous H8 designvalves.
Service Information
Refer to specific Eaton partsdrawing for service partsinformation.
Order by literature number.
DG3V-85007.03/EN/0196/S
DG5V-8-*S5007.04/EN/0196/S
DG5V-8-*H5007.04/EN/0196/S
3EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
Table of Contents
DG3V-8 Remote Pilot Operated Directional Valves
Model Code..........................................................................................................................................................................................................4
Model Description/Performance Characteristics ..............................................................................................................................................5
Spool Type and Center Position ........................................................................................................................................................................6
Curves ..............................................................................................................................................................................................................7
Response Time ....................................................................................................................................................................................................8
Installation Dimensions ....................................................................................................................................................................................9
Optional Features ..............................................................................................................................................................................................11
DG5V-8 Pilot Operated Directional Valves
Model Code........................................................................................................................................................................................................12
Model Description/Performance Characteristics .......................................................................................................................................... 14
Spool Type and Center Position ......................................................................................................................................................................15
Curves ............................................................................................................................................................................................................16
Shift Response Times ......................................................................................................................................................................................17
Pilot Valves ........................................................................................................................................................................................................18
Installation Dimensions ..................................................................................................................................................................................19
Optional Features ............................................................................................................................................................................................ 24
Electrical Information ......................................................................................................................................................................................26
Valve for Safety Circuit Applications (35A Spool) ..........................................................................................................................28
Mounting Surface ............................................................................................................................................................................................36
Application Data ..............................................................................................................................................................................................36
Released Assembly Numbers of Valve with Main Spool Monitoring Switch ............................................................................................37
4 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
Model CodesDG3V-8 Remote Pilot
Operated Directional Valves
Special Seals
(Omit if not required.)F3 – Seals for fire resistant
fluids.F6 – Seals for water glycol.
Directional Control Valve
DG3V – Subplate mounting;pilot operated-remote operator.Pressure rating 350 bar (5000psi) for all ports. (See mini-mum pilot pressurerequirements on page 6.)
Valve Size
8 – Valve size CETOP 8, NFPA D08
Gauge Ports
Blank - .4375-20 UNF-2BThread
B -1/4 BSP Thread
Spool Types
0 – Open to T all ports1 – Open P&A to T, closed B2 – Closed to T all ports3 – Closed P&B, open A to T4 – Tandem P to T, closed
crossover6 – Closed P only, open A&B
to T7 – Open P to A&B, closed T8 – Tandem P to T, open
crossover9 – Open to T all ports over
tapers11 – Open P&B to T, closed A31 – Closed P&A, open B to T33 – Closed P, open A&B to T
over tapers35 – Closed cross over
(ONLY 35A available)52 – Closed center, regen. by
operator ‘A’521 – Closed center, regen. by
operator ‘B’
Spool Spring Arrangement
Blank - No springA - Spring offset to cylinder ‘A’C - Spring centeredD - Pressure centered
Left Hand Build
L - A Models only, omit if notrequired.
Fast Response
(Omit for standard low shockmodels.)
X- Not recommended for pilot-pressures above 210bar (3000 psi).
Spool Control
Modifications
(Omit if not required.)1 - Stroke adjustment (both
ends) (available on C &Blank (no spring) models)
2 - Pilot choke adjustment(available on all models)
3 - Pilot choke and strokeadjusters (both ends) (avail-able on C & Blank (nospring) models)
7 - Stroke adjusters on cylin-der A end only (available onA, C & Blank (no spring)models)
8 - Stroke adjusters on cylin-der ‘B’ end only (availableon A, C, & Blank (no spring)models)
27 - If both are required (avail-able on A, C, & Blank (nospring) models)
28 - If both are required (avail-able on AL left hand
Check Valve in Pressure
Port
(Omit if not required.)K - 0,35 bar (5 psi) checkQ - 2,42 bar (35 psi) checkR - 3,45 bar (50 psi) checkS - 5,20 bar (75 psi) check
Design Number
Subject to change. Installationdimensions remain as shownfor design numbers 10 through19.
Special Modifications
(Omit if not required.)
12
11
10
9
8
7
6
5
4
3
2
1
(F*) DG3V 8 (B) ** (L) (X) (*) (*) 10 (EN**)
1 7 122 3 4 5 6 8 9 10 11
RatingsMAX. FLOW W/OUT MAX. FATIGUE PRESSURE MAX. OPERATING MAX. OPERATINGMALFUNCTION* (PORTS P, A, B & T) PRESSURE PRESSURE (PORTS T & Y) MOUNTING PATTERN
L/min (USgpm) bar (psi) bar (psi)To 700 (185) 350 (5000) 350 (5000) 350 (5000) CETOP 8
ISO 4401 SIZE 8NFPA D08
* See malfunction flow curves on page 7.
5EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
ModelDescription/PerformanceCharacteristics
General Description
DG3V-8 models are singlestage remote pilot operateddirectional control valves.These valves are generallyused to control the directionof flow in a hydraulic circuit.This in turn would control themovement of a work cylinderor the rotation of a fluidmotor.
Installation Data
Drain connection must bepiped directly to tank througha surge free line so there willbe no back pressure at thisport.
Pressure Centered Models
Designated by ‘‘D’’ underspring/spool arrangement inmodel code.
This option provides faster,more positive spring center-ing time by use of pilot pres-sure to center the spool. Thevalve spool is returned tocenter position when pilotpressure is applied at bothends of the spool. The cen-tering springs are used inaddition to pilot pressure toensure positive centering ofspool.
If pilot pressure fails or fallsbelow the required minimum,the spool will spring return tothe center position. Pilot pres-sure is not available throughthe use of and integral checkvalve. Pressure centeredvalves have a drain port ‘‘W’’and subplate must have provi-sions for this feature.
Note
Pressure centered valvesrequire a pilot valve whichdirects pilot oil to connec-tions ‘‘X’’ and ‘‘Y’’ of thevalve at the same time pres-sure centering is desired. The
centering time depends onthe rate of pressure rise inthe pilot chamber.
Spring Offset Models
Designated by ‘‘A’’ underspring/spool arrangement inmodel code.
Spring offset model has aninternal spring which returnsthe spool to offset positionwhen the pilot connection‘‘X’’ is open to tank. Pilotconnection ‘‘Y’’ becomes adrain connection and mustbe pioped directly to tank atatmospheric pressurethrough a surge-free tankline. Back pressure at thisconnection would causevalve to malfunction.
Caution: Spring off-set models containa high assembled
spring load. Call EatonService for disassemblyinstructions.
Spring Centered Models
Designated by ‘‘C’’ underspring/spool arrangement inmodel code.
A spring and washer arrange-ment is used on both endsof the spool. If control pres-sure is removed, the valvewill go to center position dueto spring force.
No-Spring Models
Designated by a ‘‘Blank’’under spring/spool arrange-ment in model code.
When pilot pressure isremoved on no-spring models,the spool remains in the lastposition attained providedthere is no unusual shock,vibration, pressure transientsand the spool axis is horizontal.
PerformanceCharacteristics
Spring centered, pressurecentered and spring offsetmodels require continuouspilot pressure to maintainshifted position. Spring cen-tered models return valvespool to center position bycentering springs when pilotpressure fails or falls belowminimum requirement.
Port connections are madeby mounting the valves on asubplate or manifold havingmounting dimensions whichconform to NFPA-D08/D10(ISO-4401-08/10) pattern.
Shift Times
Shift times are defined asthe time from pilot pressureapplication/removal to thepoint of the start of a pres-sure rise/decline in appropri-ate port.
Caution: Flow con-ditions of the springcentered position
must be selected with care,both for the effect on thedirection of the flow, and thepilot pressure. (The “9” mainspool will not ensure suffi-cient pilot pressure in thecenter position for internalpilot pressure models.)
Pressure centered models:Valve spool is returned tocenter position by pilot pres-sure, when pilot pressure isremoved. If pilot pressurefails or falls below therequired minimum, the valvespool will spring return tocenter position. (At springcentered valve flow rates).
Caution: Surges ofoil in a commonpilot valve drain line
serving these and othervalves can be of sufficientmagnitude to cause inadver-tant shifting of these valves.This is particularly critical inthe no-spring type valves.Separate drain lines or avented drain manifold with acontinuous downward pathto tank is necessary. Thisapplies to connection ‘‘Y’’ onspring offset valves where‘‘Y’’ is piped as a drain forpressure centered models.Drain connection ‘‘W’’ mustbe piped directly to tankthrough a surge free line sothere will be no back pres-sure at drain.
Note
Any sliding spool valve, if heldfor long periods of time, maystick and not spring returndue to fluid residue formationand therefore, should becycled periodically to preventthis from happening.
If used as other than a nor-mal 4–way valve, consultyour Eaton representative.
MINIMUM PILOT PRESSURE REQUIREMENTS
Spool Type Pilot Pressure bar (psi) p ypBlank, A, C Models D Models
Closed center 10 (150) P to A: 12 (175)P to B: 21 (300)
Open center 5 (75) P to A: 10 (150)P to B: 10 (150)
6 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
Spool Type andCenter Position
SPOOL TYPE AND CENTER POSITION
Spool Center Spool Center Spool Center Spool Center Spool CenterType Position Type Position Type Position Type Position Type Position
GRAPHICAL SYMBOLS
Spring Offset ‘A’ Spring Centered ‘C’ Pressure Centered ‘D’ No-Spring
FLOW RATINGS
Maximum flow without malfunction See malfunction flow curves on page 7.Maximum fatigue pressure (P, A, B & T ports)* 350 bar (5000 psi)Maximum operating pressure (P, A, B & X ports) 350 bar (5000 psi)Maximum operating pressure (T & Y ports) 350 bar (5000 psi)* The method for verifying the rated fatigue pressure of the complete unit conforms to NFPA/T2.6.1 R1-1991 (Catalog C/90), Fluid Power Systems and Products method for verifying the fatigue pressure rating of the pressurecontaining envelope.
A B
P T
A B
P T
A B
P T
0
1
2
A B
P T
4
(ClosedCrossover)
6
7
A B
P T
A B
P T
9
A B
P T
8
(OpenCrossover)
A B
P T
11
A B
P T
A B
P T
3
A B
P T
31
A B
P T
33
A B
P T
A B
P T
A B
P T
A B
P T
A B
P TW DRAIN
A B
P TY DRAIN
52
35A
521
A B
P T
7EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
Curves
Pressure Drop &Malfunction Flow
The following table lists theappropriate pressure dropcurve and malfunction flowcurve between ports foreach spool type. Use the fol-lowing example to determinepressure drop for a selectedspool.
Example: Find the pressuredrop from P B for type 7spool. Using the table findnumeral 7 in the spool typecolumn. To the right ofnumeral 7 find the referencecurve 2 (from pressure dropcurve chart at bottom ofpage) under P B column.
The pressure drop from P Bfor type 7 spool would beobtained on curve 2.Likewise, the malfunction fornumeral 7 would be foundon curve 1 (from malfunctionflow curve chart at bottom ofpage).
Spool Pressure Drop Curve Number Malfunction FlowType P A B T P B A T P T In Center Curve Number0 2 2 2 2 3 11 1 2 1 3 2 311 1 3 1 1 3 32 1 2 1 1 – 23 1 2 1 4 – 231 1 3 1 1 – 24 4 3 4 2 5 36 1 3 1 4 – 17 2 2 2 1 – 18 4 3 4 2 5 19 2 3 2 2 28 bar (400 psid) 4
@ 189 L/min (50USgpm)
33 1 3 1 2 – 235 See page 2852 2 – 4 4 – 1521 2 4 4 – – 1
1. Figures in the pressuredrop chart give approximatepressure drop (ΔP) whenpassing 473 l/min (125USgpm) flow (Q) of 35 cSt(164 SUS) fluids(s) having.865 specific gravity.
2. For any other flow rate(Q1), the pressure drop (ΔP1)will be approximately: ΔP1 = P(Q1/Q)2.
3. For any other viscosity(s),the pressure drop (ΔP), willchange as follows:
4. For any other specificgravity (G1), the pressuredrop (ΔP1) will be approxi-mately: ΔP1 = ΔP(G1/G).
ViscositycSt 14 20 43 54 65 76 85(SUS) (17.5) (97.8) (200) (251) (302) (352) (399)% of PΔ 81 88 104 111 116 120 124(Approx.)
Pressure Drop Curves Malfunction Flow Curves
FLOW – USgpm
FLOW – L/min
20 40 60 80 100 120 140 160 180 200
P
OR
D E
RU
SS
ER
P–
rab
P
OR
D E
RU
SS
ER
P–
isp
0
50
100
150
200
250
300
350
400
450
1
2
34
5
7,0
10,0
17,0
20,0
3,5
0
14,0
24,0
27,5
31,0
76151
227303
379454
530606
681757
20 40 60 80 100 120 140160 180
76 227 379 530 681
200
FLOW – L/min
151 303 454 606 757
0
1000
2000
3000
4000
5000
6000 415
350
280
210
140
70
0
4
3
2
1
PO
RD
ER
US
SE
RP
–isp
P
OR
D E
RU
SS
ER
P–
rab
FLOW – USgpm
8 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
Response Time
Response Time
The response time shown inthe charts are defined as thetime between pilot pressur-ization/de-pressurization andthe initial change in the inletport pressure.
Offset to Offset
Center to Offset
SPRING CENTERING TIMES @RATED FLOW & PRESSURE
Spool Type TimeClosed Center .040 sec.Open Center .050 sec.
Centering Times for PressureCentered Valves @ RatedPressure (A to P or B to P)
0
10
20
30
40
50
60
0
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
Low shock shift
Low shock spring return
Fast response shift
Fast response spring return
Pilot pressure - psi
Pilot pressure - bar35 70 100 140 175 210 280 310 350240
cesm - e
miT
Pilot pressure - bar
0
10
20
30
40
50
60
70
80
0
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
Low shock
Fast response
35 70 100 140 175 210 280 310 350240
Pilot pressure - psi
cesm - e
miT
ee malfunction flow curves on page 7.
350 bar (5000 psi)
350 bar (5000 psi)
350 bar (5000 psi)
nforms to NFPA/T2.6.1 R1-1991e fatigue pressure rating of the
9EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
SPOOL CONTROL MODIFICATIONS ‘‘A’’ ‘‘B’’ ‘‘C’’ ‘‘D’’ DIMENSION (PILOTDIMENSION DIMENSION DIMENSION CHOKE ADJUSTMENT)
Without pilot choke or stroke adjustment 133,0 (5.23) 265,3 (10.44) 132,6 (5.22) –Stroke adjustment (both ends) 133,0 (5.23) 415,9 (16.37) 208,0 (8.18) –Pilot choke adjustment 173,0 (6.81) 265,3 (10.44) 132,6 (5.22) 134,2 (5.28)Stroke adjustment on cyl. ‘A’ 133,0 (5.23) 340,6 (13.40) 208,0 (8.18) –Stroke adjustment on cyl. ‘B’ 133,0 (5.23) 340,6 (13.40) 132,6 (5.22) –Pilot choke and stroke adjustment on cyl. ‘A’ 173,0 (6.81) 340,6 (13.40) 208,0 (8.18) 134,2 (5.28)Pilot choke and stroke adjustment on cyl. ‘B’ 173,0 (6.81) 132,6 (5.22) 134,2 (5.28) 134,2 (5.28)Pilot choke and stroke adjustment (both ends) 173,0 (6.81) 415,9 (16.37) 208,0 (8.18) 134,2 (5.28), )
InstallationDimensions
164,9 (6.49) 75,0(2.95)
81,0 (3.19)
ʻʻAʼʼ
ʻʻCʼʼ
ʻʻBʼʼ
ʻʻDʼʼ
See pilot chokeadjustment installationfor additionaldimensions not shown.
Gauge ports.4375-20 UNF-2Bthread for .250 O.D. tubing or 1/4 BSPthread
80,9(3.19)
41,0(1.61)
53,0(2.09)
100,7 (3.96)187,3(7.38)
31,0(1.22)
130,2(5.13)
53,2(2.09)
35,4(1.39)
70,8(2.79)
153,0 (6.02)
77,0(3.03)
46,1 (1.81) 92,1(3.63)
Mounting bolt holes∅13,5 (0.53)6 places
Port B∅ 25,0 (0.98)
Port A∅ 25,0 (0.98)
Pilot Pressure Port X
Tank Port ∅ 25,0 (0.98)
Pressure Port∅ 25,0 (0.98) Std. Model∅ 27,3 (1.07) P-Port Check Model
118,5 (4.67)
46,0(1.81)
35,5(1.40)
111,0 (4.37)
58,5(2.30)
Dimension to mountingbolt counterbore hole6-places
∅ 6,4 (0.25) Orientation Pin2-places
6,5(0.25)
42,5(1.67)
Pilot Pressure Port Y
DG3V-8-(C)-*-*-10 SpringCentered Model
Millimeters (inches)
10 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
SPOOL CONTROL MODIFICATIONS ‘‘A’’ ‘‘B’’ ‘‘C’’ ‘‘D’’ DIMENSION (PILOTDIMENSION DIMENSION DIMENSION CHOKE ADJUSTMENT)
Without pilot choke or stroke adjustment 133,0 (5.23) 265,3 (10.44) 132,6 (5.22) –Without pilot choke or stroke adjustment 133,0 (5.23) 326,9 (12.87) 194,4 (7.65) 134,2 (5.28)(left-hand build)Pilot choke adjustment 173,0 (6.81) 265,3 (10.44) 132,6 (5.22) 134,2 (5.28)Stroke adjustment on cyl. ‘A’ (left-hand build) 133,0 (5.23) 402,3 (15,83) 208,0 (8.18) –Stroke adjustment on cyl. ‘B’ 133,0 (5.23) 340,6 (13.40) 132,6 (5.22) –Pilot choke and stroke adjustment on cyl. ‘A’ 173,0 (6.81) 340,6 (13.40) 208,0 (8.18) 134,2 (5.28)(left-hand build)Pilot choke and stroke adjustment on cyl. ‘B’ 173,0 (6.81) 340,6 (13.40) 132,6 (5.22) 134,2 (5.28)
InstallationDimensions
DG3V-8-(L)-*-*-10 SpringOffset Model
Millimeters (inches)
83,4(3.28)
194,4 (7.65)
ʻʻAʼʼ
ʻʻDʼʼ
ʻʻCʼʼ
ʻʻBʼʼ
Millimeters (inches)
ʻʻAʼʼ
ʻʻDʼʼ
ʻʻBʼʼ
193,5 (7.62)
84,9(3.34)
DG3V-8-D-*-*-10 PressureCentered Model
Millimeters (inches)
11EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
Optional Features
Integral Check Valves
For internal pilot pressure, anintegral pressure port checkvalve is available. This backpressure will be present atthe cylinder ports. The pilotpressure generated is thetotal of: P T drop throughthe valve in center condition,pressure drop through thecheck valve, plus the pres-sure at the tank port.
To prevent load drop, a checkvalve in the pressure portcan be used to preventreverse flow from a cylinderport to the pressure port.
Pilot Choke DGMFN-3-Y-A2W-B2W-41
Pilot choke increases theamount of time to shift themainstage spool, loweringthe possibility of large flowtransients in the circuit. It isadjusted by backing off lock-nuts and turning adjustingscrews inward to decreaserate of spool travel and out-ward to increase spool travelrate. See spool control modi-fications in model code.
Stroke Adjustment
Stroke adjustment limitsmovement of the mainstagespool. Backing off the jamnutand turning the adjustingscrew inward decreasesspool stroke. See spool con-trol modifications in modelcode.).
Pressure Drop Across Check Valve
0 20 40 60 80 100 120 140 160 180 200
75.7151.4
227.1302.8
378.5454.2
529.9605.6
681.3757.0
6,9
13,8
20,7
27,6
34,5
41,4
48,3
00
700
600
500
400
300
200
100
FLOW - USgpm
FLOW - L/min
rab - P
OR
D E
RU
SS
ER
P
i sp - P
OR
D E
RU
SS
ER
P
ʻʻR ʼʼ Spring
ʻʻSʼʼ Spring
ʻʻKʼʼ Spring
ʻʻQʼʼ Spring
Pilot Choke
Stroke Adjustment
12 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
Model CodesDG5V-8 Remote Pilot
Operated Directional Valves
Special Seals
(Omit if not required.)F3 – Seals for fire resistant
fluids.F6 – Seals for water glycol.
Directional Control Valve
DG5V – Subplate mounting;pilot operated. Pressure rating350 bar (5000 psi) for all ports.(See minimum pilot pressurerequirements on p. 15.)
Valve Size
8 – Valve size CETOP 8, NFPAD08
Pilot Valve Type
H - CETOP 3, High performance
S - CETOP 3, Standard performance
Reducer Module
See Fast Response restriction.(Omit if not required.)
Gauge Ports
Blank - .4375-20 UNF-2BThread
B -1/4 BSP Thread
Spool Types
0 – Open center (all ports)1 – Open center (P to A & T) B
blocked2 – Closed center (all ports)3 – Open center (P & B
blocked) A to T4 – Tandem center (P to T)
closed crossover6 – Closed center (P blocked)
A & B to T7 – Open center (P to A & B) T
blocked8 – Tandem center (P to T)
open crossover9 – Open center, partial to all
ports11 – Open center (P to B & T)
A blocked
31 – Closed center (P & Ablocked) B to T
33 – Closed center, bleed A &B to T
35 – Closed cross over (all ports)(ONLY 35A available)
52 – Closed center (All ports)regen. towards workport A
521 – Closed center (All ports)regen. towards workport B
Spool Spring Arrangement
A - Spring offset to ‘A’ portB - Spring centered, with
solenoid ‘A’ removedC - Spring centeredD - Pressure centeredF - Spring offset to ‘A’ port,
shift to centerN - No spring detented (pilot
valve only)
Left Hand Build
L - Single solenoid modelsonly, omit if not required.
Manual Override Options
Blank - Plain override in sole-noid ends only
H - Waterproof override insolenoid ends only
H2 - Waterproof override in bothends of single solenoid
P2 - Plain override in bothends of single solenoid
Y - Lockable manual overridein solenoid ends only (DCmodels only)
Z - No override in either end
Fast Response
X- Not recommended for pilotpressures above 210 bar (3000
psi). (Omit for standardlow shock models.)
When the standard perform-ance pilot is selected and pilotpressure is above 3000 psi,the reducer module is requiredto limit high drain line pressuretransients generated duringshifting.
Spool Control
Modifications
(Omit if not required.)1 - Stroke adjustment (both
ends) (not available on Dmodels)
2 - Pilot choke adjustment(available on all models)
3 - Pilot choke and strokeadjusters (both ends) (notavailable on D models)
7 - Stroke adjusters on A portend only (not available on Dmodels)
8 - Stroke adjusters on B portend only (available on allmodels)
27 - 2 and 7 combined (notavailable on D models)
28 - 2 and 8 combined (avail-able on all models)
Main Stage Spool
Monitoring Switch
(Omit if not required.)PCA - Center sensing switch
on “A” port end (notavailable on “D”, pres-sure centered, and1/3/7/27, stroke adjustmodels)
PCB - Center sensing switchon “B” port end (notavailable on 1/3/8/28,stroke adjust models)
PDA - Double offset sensingswitch on “A” port end(not available on “D”,pressure centered, and1/3/7/27, stroke adjustmodels)
PDB - Double offset sensingswitch on “B” port end(not available on1/3/8/28, stroke adjustmodels)
PCD - Center sensing switchon “A” port end anddouble offset sensingswitch on “B” port end(not available on “D”,pressure centered, and1/3/7/8/27/28, strokeadjust models)
PPA - Offset sensing proximityswitch “A” port end (notavailable on “D”, pres-sure centered, and1/3/7/27, stroke adjustmodels)
PPB - Offset sensing proximityswitch “B” port end (notavailable on 1/3/8/28,stroke adjust models)
PPD - Offset sensing proximityswitch both ends (notavailable on “D”, pres-sure centered, and1/3/7/8/27/28, strokeadjust models)
* The spool position monitoring switchshown on this technical document is CEmarked and certified and complies toEuropean Standard EN 61000-6-4: 2001(Emissions) for Class A and EuropeanStandard EN 61000-6-2: 2001(Immunity).
External Pilot Pressure
E - External pilot pressure.Omit for internal pilot pressure models.
Internal Pilot Drain
T - Internal pilot drain to ‘T’ port. Omit for external pilot drain models.
Check Valve in
Pressure Port
(Omit if not required.)K - 0,35 bar (5 psi) checkQ - 2,42 bar (35 psi) checkR - 3,45 bar (50 psi) checkS - 5,20 bar (75 psi) check
13
15
14
10
6
5
16
12
11
9
8
7
4
3
2
1
2 3 4 7 5 8 1 10 11 12 14 15 16 17 18 19 20 9 2721 22 23 24 25 26 286 29 13
P P
P
13EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
Solenoid Energization
Identity
Blank - Standard arrangementfor ANSI B93.9 (i.e.energize solenoid A tofollow flow P to A).
V - Solenoid identificationdetermined by position ofsolenoid (i.e. solenoid A atport A end/solenoid B atport B end).
Note4 and 8 type spools are alwaysV. Solenoid energization identi-ty is independent of main-stage porting.
Heading Electrical Flag Symbol
M - Features and options forpilot valve.
Pilot Valve
Monitoring Switch
S3 - Limit switch normallyopen, wired to electricalconnector withPA/PB/PA5 (H piloted models only)
S4 - Limit switch normallyclosed, wired to electricalconnector withPA/PB/PA5 (H piloted models only)
S5 - Limit switch normallyclosed, wired to electricalconnector withPA/PB/PA5 (H piloted models only)
S6 - Position switch with U coils (H piloted models only)
Coil Type
F - Flying lead (required forwiring housing option)
KU - Top exit flying leadP - Plug inSP1 - Single 6.3mm spadeSP2 - Dual 6.3mm spadeU - ISO 4400 (DIN 43650)X1 - Flameproof solenoids
BASEEFA/CENELEC (S piloted models only)
X2 - Explosion proof solenoidsCSA/UL (S piloted models only)
X3 - Explosion proof solenoidsBASEEFA ExS (S piloted models only)
Electrical Connections
(F type coils only, omit if notrequired)PA – Insta–plug, male
receptacle onlyPB – Insta–plug, male and
female receptaclePA3 – 3–pin connectorPA5 – 5–pin connectorT – Wired terminal block
(wiring housing option also required)
Wiring HousingW – 1/2” NPT threaded
connectionJ – 20mm threaded
connectionG – 1/2” BSP threaded
connection
Electrical Options
(Omit if not required)U-type coils only1 – Fitted connector2 – Fitted connector and variable grommet6 – Fitted connector with lights
Solenoid Indicator Lights
(Omit if not required)
Electrical Options
(DC voltages only, omit if notrequired)D1 – Encapsulated diode
(industrial applications)D2 – Encapsulated diode
(mobile applications)D7 – Encapsulated transzorb
Coil Identification Letter
See electrical information onpage 25 for voltages available.Others available upon request.
Pilot Valve Port Orifices
(Omit if not required)
Design Number
Special Modifications
(Omit if not required)
28
17
20
19
18
29
28
27
26
25
24
23
21
2 3 4 7 5 8 1 10 11 12 14 15 16 17 18 19 20 9 2721 22 23 24 25 26 286 29 13
P P
P
RatingsMAX. FLOW W/OUT MAX. FATIGUE PRESSURE MAX. OPERATING MAX. OPERATINGMALFUNCTION* (PORTS P, A, B & T) PRESSURE PRESSURE (PORTS T & Y) MOUNTING PATTERN
L/min (USgpm) bar (psi) bar (psi)To 700 (185) 350 (5000) 350 (5000) 350 (5000) CETOP 8
ISO 4401 SIZE 8NFPA D08
* See malfunction flow curves on page 16.
14 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
ModelDescription/PerformanceCharacteristics
General Description
DG5V-8 models are two-stage directional controlvalves having an integrallymounted wet armature sole-noid pilot valve. These valvesare generally used to controlthe movement of a workcylinder or the rotation of afluid motor.
Pressure Centered Models
Designated by ‘‘D’’ underspring/spool arrangement inmodel code.
This option provides faster,more positive spring center-ing time by use of pilot pres-sure to center the spool. Thevalve spool is returned tocenter position when pilotpressure is applied at bothends of the spool. The cen-tering springs are used inaddition to pilot pressure toensure positive centering ofspool.
If pilot pressure fails or fallsbelow the required mini-mum, the spool will springreturn to the center position.Pilot pressure is not availablethrough the use of and inte-gral check valve. Pressurecentered valves have a drainport ‘‘W’’ and must have pro-visions for this feature.
Note
Pressure centered valvesrequire a pilot valve whichdirects pilot oil to connec-tions ‘‘X’’ and ‘‘Y’’ of thevalve at the same time pres-sure centering is desired. Thecentering time depends onthe rate of pressure rise inthe pilot chamber.
Spring Offset Models
Designated by ‘‘A’’ underspring/spool arrangement inmodel code.
Spring offset model has aninternal spring which returnsthe spool to offset positionwhen the pilot connection‘‘X’’ is open to tank. Pilotconnection ‘‘Y’’ becomes adrain connection and mustbe pioped directly to tank atatmospheric pressurethrough a surge-free tankline. Back pressure at thisconnection would causevalve to malfunction.
Caution: Spring off-set models containa high assembled
spring load. Call EatonService for disassemblyinstructions.
Spring Centered Models
Designated by ‘‘C’’ underspring/spool arrangement inmodel code.
A spring and washer arrange-ment is used on both endsof the spool. If control pres-sure is removed, the valvewill go to center position dueto spring force.
No-Spring Models
Designated by a ‘‘Blank’’under spring/spool arrange-ment in model code.
When the solenoid is de-ener-gized, the spool returns to thelast position attained.PerformanceCharacteristics
Spring centered, pressurecentered and spring offsetmodels require continuouspilot pressure to maintainshifted position. Spring cen-tered models return valvespool to center position bycentering springs when pilotpressure fails or falls belowminimum requirement.
Shift Times
Shift times are defined asthe time from pilot pressureapplication/removal to thepoint of the start of a pres-sure rise/decline in appropri-ate port.
Caution: Flow con-ditions of the springcentered position
must be selected with care,both for the effect on thedirection of the flow, and thepilot pressure. (The “9” mainspool will not ensure suffi-cient pilot pressure in thecenter position for internalpilot pressure models.)
Pressure centered models:
Valve spool is returned tocenter position by pilot pres-sure, when pilot pressure isremoved. If pilot pressurefails or falls below therequired minimum, the valvespool will spring return tocenter position. (At springcentered valve flow rates).
Caution: Surges ofoil in a commontank line serving
these and other valves canbe sufficient enough tocause inadvertent shifting ofthese valves. This is very crit-ical in the no-spring detentedvalves. Separate tank lines ora vented manifold with acontinuous downward pathto tank is necessary.
Note
Any sliding spool valve, ifheld for long periods of time,may stick and not springreturn due to fluid residueformation and therefore,
should be cycled periodicallyto prevent this from happen-ing.
Shifting Action
The pilot valve solenoids ofspring centered, pressurecentered, and spring offsetmodels must be energizedcontinuously to keep themain stage spool in the shift-ed position. No-springdetented models only needto be energized momentarily(for approximately 0.1 sec-ond).
Spring centered and pres-sure centered models returnthe valve spool to the centerposition when both solenoidsare de-energized or pilotpressure fails or falls belowminimum requirements.Spring offset models returnthe spool to the offset posi-tion by pilot pressure whenthe solenoid is de-energized.
When no-spring detentedmodels are de-energized, thepilot and main spools remainin their last position as longas there are no unusualshock, vibration, or pressuretransients, and the spool axisis horizontal. If pilot pressurefails or falls below minimumrequirements, the mainspool will spring center (atspring centered flow rates),but will not drift to a reversalof flow position. The pilotstage will remain in thedetented position.
When used as other than anormal 4–way valve, consultyour Eaton representative.
MINIMUM PILOT PRESSURE REQUIREMENTS
Spool Type Pilot Pressure bar (psi) A, B, C, F, N Models D Models
Closed center 10 (150) P to A: 12 (175)P to B: 21 (300)
Open center 5 (75) P to A: 10 (150)P to B: 10 (150)
15EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
Spool Type andCenter Position
SPOOL TYPE AND CENTER POSITION
Spool Center Spool Center Spool Center Spool Center Spool CenterType Position Type Position Type Position Type Position Type Position
GRAPHICAL SYMBOLS
FLOW RATINGS
Maximum flow without malfunction See malfunction flow curves on page 7.Maximum fatigue pressure (P, A, B & T ports)* 350 bar (5000 psi)Maximum operating pressure (P, A, B & X ports) 350 bar (5000 psi)Maximum operating pressure (T & Y ports)§ 350 bar (5000 psi)* The method for verifying the rated fatigue pressure of the complete unit conforms to NFPA/T2.6.1 R1-1991 (Catalog C/90), Fluid Power Systems and Products method for verifying the fatigue pressure rating of the pressurecontaining envelope.§ Internal drain models drain the pilot valve through the tank port of the mainstage. External drain models drain the pilot valve through the ‘‘Y’ port of the mainstage. To provide proper operation without malfunction, thepilot pressure must always exceed tank or drain line pressure by the minimum pilot pressure required per valve and spool type (see charts on page 16). Tank or drain line surges which would reduce this differential are tobe avoided as they may cause the mainstage to shift. Mainstage tank pressure is limited to the tank line rating of the pilot valve on internally drained models (with ‘‘T’’ included in the model code). Internal drains may beused with all models except pressure centered ‘‘D’’ models. Pressure centered models must be externally drained through ‘‘Y’’ and ‘‘W’’ ports. To achieve the maximum tank line rating of 350 bar (5000 psi) of the mainstage,an external pilot drain must be used and it is recommended that a separate line be provided directly to the tank.
A B
P T
A B
P T
A B
P T
0
1
2
A B
P T
4
(ClosedCrossover)
6
7
A B
P T
A B
P T
9
A B
P T
8
(OpenCrossover)
A B
P T
11
A B
P T
A B
P T
3
A B
P T
31
A B
P T
33
A B
P T
SPRING OFFSET ʻAʼ
A B
P T
SPRING CENTERED ʻCʼ
A B
P T
PRESSURE CENTERED ʻDʼ
W DRAIN
A B
P T
NO-SPRING DETENTED ʻNʼ
A B
P T
Y DRAIN
SPRING OFFSETSHIFT TO CENTER ʻFʼ
A B
P T
b
SPRING CENTEREDSINGLE SOLENOID ʻBʼ
Y DRAIN
Y DRAIN
A B
P T
A B
P T
52
35A
521
A B
P T
16 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
Pressure Drop &Malfunction Flow
The following table lists theappropriate pressure dropcurve and malfunction flowcurve between ports foreach spool type. Use the fol-lowing example to determinepressure drop for a selectedspool.
Example: Find the pressuredrop from P B for type 7spool. Using the table findnumeral 7 in the spool typecolumn.
To the right of numeral 7 findthe reference curve 2 (frompressure drop curve chart atbottom of page) under P Bcolumn.
The pressure drop from P Bfor type 7 spool would beobtained on curve 2.Likewise, the malfunction fornumeral 7 would be foundon curve 1 (from malfunctionflow curve chart at bottom ofpage).
1. Figures in the pressuredrop chart give approximatepressure drop (ΔP) whenpassing 473 l/min (125USgpm) flow (Q) of 35 cSt(164 SUS) fluids(s) having.865 specific gravity.
2. For any other flow rate(Q1), the pressure drop (ΔP1)will be approximately: ΔP1 = ΔP(Q1/Q)2.
3. For any other viscosity(s),the pressure drop (ΔP), willchange as follows:
4. For any other specificgravity (G1), the pressuredrop (ΔP1) will be approxi-mately: ΔP1 = ΔP(G1/G).
Curves
FLOW – USgpm
FLOW – L/min
20 40 60 80 100 120 140 160 180 200
P
OR
D E
RU
SS
ER
P–
rab
P
OR
D E
RU
SS
ER
P–
is p
0
50
100
150
200
250
300
350
400
450
1
2
34
5
7,0
10,0
17,0
20,0
3,5
0
14,0
24,0
27,5
31,0
76151
227303
379454
530606
681757
20 40 60 80 100 120 140160 180
76 227 379 530 681
200
FLOW – L/min
151 303 454 606 757
0
1000
2000
3000
4000
5000
6000 415
350
280
210
140
70
0
4
3
2
1
P
OR
D E
RU
SS
ER
P–
isp
P
OR
D E
RU
SS
ER
P–
rab
FLOW – USgpm
Pressure Drop Curves Malfunction Flow Curves
SPOOL MALFUNCTIONTYPE PRESSURE DROP CURVE NUMBER FLOW CURVE NUMBER
P A B T P B A T P T In Center
0 2 2 2 2 3 11 1 2 1 3 2 311 1 3 1 1 3 32 1 2 1 1 – 23 1 2 1 4 – 231 1 3 1 1 – 24 4 3 4 2 5 36 1 3 1 4 – 17 2 2 2 1 – 18 4 3 4 2 5 19 2 3 2 2 28 bar (400 psid) 4
@ 189 L/min(50 USgpm)
33 1 3 1 2 – 235A See page 2852 2 – 4 4 – 1521 2 4 4 – – 1
ViscositycSt 14 32 43 54 65 76 86(SUS) (75) (150) (200) (250) (300) (350) (400)% of PΔ 93 111 119 126 132 137 141(Approx.)
17EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
Response Times
Response times are definedas the time from solenoidenergization/de-energizationto the point of the start of apressure rise/decline inappropriate port.
Solenoid Energizing
Spring centered, pressurecentered and spring offsetDG5V-8 types must be ener-gized continuously. No-springdetented DG5V-8 type maybe energized momentarily.Pressure centered and springcentered DG5V-8 typesreturn valve spool to centerposition when both solenoidsare de-energized.
Mounting Position
No–spring detented valvesmust be installed with thelongitudinal axis horizontal forgood machine reliability. Themounting position of springcentered and spring offsetmodels is unrestricted pro-vided that the pilot pressuresupply is maintained asrequired. (Spring offsetvalves do not have a springin the main spool section.)
Shift ResponseTimes
0
10
20
30
40
50
60
0
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
Low shock solenoid shift
Low shock spring return
Fast response solenoid shift
Fast response spring return
Pilot pressure - psi
Pilot pressure - bar35 70 100 140 175 210 280 310 350240
cesm - e
miT
Pilot pressure - bar
0
10
20
30
40
50
60
70
80
0
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
Low shock
Fast response
35 70 100 140 175 210 280 310 350240
cesm - e
miT
Offset to Offset
SPRING CENTERING TIMES @RATED FLOW & PRESSURE
Spool Type Time
Closed Center .040 sec.Open Center .050 sec.
Center to Offset Centering Times for PressureCentered Valves @ RatedPressure (A to P or B to P)
Pilot pressure - bar
0
100
2040
60
80cesm - e
miT
120 70 140 210
Pilot pressure - psi
1000 2000 3000
Standard Low ShockFast Response
18 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
General Description
Pilot valves are identified inthe model code by the fol-lowing letters: ‘‘S’’ Standardor ‘‘H’’ High Performance.The pilot valves can beordered to match a variety ofmainstage spool types andvalve bodies.
The chart below showsordering information for eachpilot valve. For example, toorder a High Performancepilot ‘‘H’’ with a Spring Offsetmainstage ‘‘A’’, use the fol-lowing model code: DG4V-3-2A-M-*-60
Pilot Valves
VALVE MODEL CODE:HIGH PERFORMANCE/STANDARD MAIN STAGE SPOOL TYPE PILOT VALVE MODEL CODE
DG5V-8-S/H-*A-*-M-*-10 All except 4 & 8 DG4V-3(S)-2A-M-*-604A & 8A only DG4V-3(S)-2AL-VM-*-604AL & 8AL only DG4V-3(S)-2A-VM-*-60
DG5V-8-S/H-*B-*-M-*-10 All except 4 & 8 DG4V-3(S)-6B-M-*-604B & 8B only DG4V-3(S)-6BL-VM-*-604BL & 8BL only DG4V-3(S)-6B-VM-*-60
DG5V-8-S/H-*C-*-M-*-10 All except 4 & 8 DG4V-3(S)-6C-M-*-604C & 8C only DG4V-3(S)-6C-VM-*-60
DG5V-8-S/H-*D-*-M-*-10 All except 4 & 8 DG4V-3(S)-7C-M-*-604D & 8D only DG4V-3(S)-7C-VM-*-60
DG5V-8-S/H-*F-*-M-*-10 All except 4 & 8 DG4V-3(S)-6F-M-*-604F & 8F only DG4V-3(S)-6FL-VM-*-604FL & 8FL only DG4V-3(S)-6F-VM-*-60
DG5V-8-S/H-*N-*-M-*-10 All except 4 & 8 DG4V-3(S)-6N-M-*-604N & 8N only DG4V-3(S)-6N-VM-*-60
19EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
InstallationDimensions
53,2(2.09)
46,0(1.81)
92,1(3.63)
77,0(3.03)
153,0 (6.02)
35,4(1.39) 70,8
(2.79)
ʻ̒ Eʼ̓ʻ̒ Dʼ̓
Gauge ports.4375-20UNF-2B thread.250 O.D. tubingor 1/4 BSP Thread
81,0(3.19)
80,9 (3.19)
41,0 (1.61)
53,0 (2.09) 100,7
(3.96) 187,3(7.38)
31,0 (1.22)
118,5 (4.67)
35,6 (1.40)
46,0 (1.81)
111,0 (4.37)
42,5 (1.67)
58,5 (2.30)
6,0(1.22)
ʻ̒ Fʼ̓
ʻ̒ Aʼ̓
ʻ̒ Bʼ̓ʻ̒ Cʼ̓
DG5V-8-S/H-*-M-*-10Spring Centered ModelMillimeters (inches)
130,2 (5.13)
Tank Port∅ 25,0 (0.98)
Pressure Port∅ 25,0 (0.98) Std. Model∅ 27,3 (1.07) P-port Check Model
Pilot Drain Port Y(For External Pilot Drain Models)
Port B∅ 25,0 (0.98)
Pilot Pressure Port X(For External PilotPressure Models)
Port A∅ 25,0 (0.98)
DimensionsSpool Control M difi i
ʻʻAʼʼ ʻʻBʼ̓ ʻʻCʼ̓ ʻʻDʼ̓ ʻʻEʼ ʼpilot ʻʻFʼ̓pModifications
AC Sol DC SolDual Solenoid Single Solenoid Pilot
AC Sol. DC Sol.AC Sol. DC Sol. AC Sol. DC Sol.
PilotChoke
Without pilot choke or strokeadjustment 135,6
265,3(10.44)
132,6(5.22)
–Stroke adjustment
(both ends)
135,6(5.33) 415,9
(16.37)208,0(8.18)
–
Pilot choke adjustment175,6(6.91)
265,3(10.44)
132,6(5.22)
134,2(5.28)
Stroke adjust. on cyl. ʻAʼ135,6
208,0(8.18) 98,8 108,8 200,0 220,0 146,5 156,5
–Stroke adjust on cyl. ʻBʼ
135,6(5.33)
340,6132,6(5.22)
98,8(3.88)
108,8(4.28)
200,0(7.87)
220,0(8.66)
146,5(5.76)
156,5(6.16) –
Pilot choke and stroke adjust. on cyl ʻAʼ
340,6(13.40) 208,0
(8.18)Pilot choke and stroke
adjust. on cyl. ʻBʼ175,6(6.91)
132,6(5.22)
134,2(5.28)
Pilot choke and strokeadjust. on both ends
(6.91)415,9
(16.37)208,0(8.18)
(5.28)
DG5V-8-S/H-*-M-*-10 Spring Centered Model
Millimeters (inches)
20 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
83,4(3.28)
194,4 (7.65)
ʻ̒ Aʼ̓
ʻ̒ Cʼ̓ʻ̒ Bʼ̓
ʻ̒ Eʼ̓ʻ̒ Dʼ̓
122,9(4.84)
ʻ̒ Fʼ̓
ʻ̒ Gʼ̓
Dimensions
Spool Control ʻʻAʼʼ ʻʻBʼ̓ ʻʻCʼ̓ ʻʻDʼ̓ ʻʻEʼ ʼpilot ʻʻFʼ̓ ʻʻGʼ̓Spool ControlModifications
AC Sol DC SolDual Solenoid Single Solenoid Reducer Pilot
AC Sol. DC Sol.AC Sol. DC Sol. AC Sol. DC Sol.
ReducerModule
PilotChoke
Without pilot choke or strokeadjustment 175,6
265,3(10.44)
132,6(5.22)
–Stroke adjustment
(both ends)
175,6(6.91) 415,9
(16.37)208,0(8.18)
–
Pilot choke adjustment215,6(8.48)
265,3(10.44)
132,6(5.22)
134,2(5.28)
Stroke adjust. on cyl. ʻAʼ175,6
208,0(8.18) 98,8 108,8 200,0 220,0 146,5 156,5 134,2
–Stroke adjust on cyl. ʻBʼ
175,6(6.91)
340,6
132,6(5.22)
98,8(3.88)
108,8(4.28)
200,0(7.87)
220,0(8.66)
146,5(5.76)
156,5(6.16)
134,2(5.28) –
Pilot choke and stroke adjust. on cyl ʻAʼ
340,6(13.40) 208,0
(8.18)
Pilot choke and strokeadjust. on cyl. ʻBʼ
215,6(8.48)
132,6(5.22)
134,2(5.28)
Pilot choke and strokeadjust. on both ends
( )
415,9(16.37)
208,0(8.18)
( )
DG5V-8-A(L)-*-*-10 Spring Offset Model
Millimeters (inches)
InstallationDimensions
21EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
ʻ̒ Aʼ̓
ʻ̒ Cʼ̓
ʻ̒ Bʼ̓
84,9(3.34)
ʻ̒ Eʼ̓ʻ̒ Dʼ̓
ʻ̒ Fʼ̓
ʻ̒ Gʼ̓
Spool Co trolDimensions
Spool Control Modifications
ʻʻAʼʼ ʻʻBʼ̓ ʻʻCʼ̓ ʻʻDʼ̓ ʻʻEʼ ʼpilot ʻʻFʼ̓ ʻʻGʼ̓Modifications
(without Reducer) AC Sol DC SolDual Solenoid Single Solenoid Reducer Pilot(without Reducer) AC Sol. DC Sol.
AC Sol. DC Sol. AC Sol. DC Sol.ReducerModule
PilotChoke
Without pilot choke or strokeadjustment 135,6
(5 33)
326,1(12.83)
193 5 98 8 108 8 200 0 220 0 146 5 156 5–
Stroke adjust on cyl. ʻBʼ(5.33)
401 5193,5(7.61)
98,8(3.88)
108,8(4.28)
200,0(7.87)
220,0(8.66)
146,5(5.76)
156,5(6.16) –
Pilot choke and strokeadjust. on cyl. ʻBʼ
175,6(6.91)
401,5(15.80)
(7.61) (3.88) (4.28) (7.87) (8.66) (5.76) (6.16)134,2(5.28)
(With reducer)
Without pilot choke or strokeadjustment 175,6
(6 91)
326,1(12.83)
193 5 98 8 108 8 200 0 220 0 146 5 156 5 131 0–
Stroke adjust on cyl. ʻBʼ(6.91)
401 5193,5(7.61)
98,8(3.88)
108,8(4.28)
200,0(7.87)
220,0(8.66)
146,5(5.76)
156,5(6.16)
131,0(5.15)
Pilot choke and strokeadjust. on cyl. ʻBʼ
215,6(8.48)
401,5(15.80)
(7.61) (3.88) (4.28) (7.87) (8.66) (5.76) (6.16) (5.15)134,2(5.28)
DG5V-8-D-*-*-10 Pressure Centered Model
Millimeters (inches)
InstallationDimensions
22 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
Pilot ChokeDGMFN-3-Y-A2W-B2W-41
Pilot choke increases theamount of time to shift themainstage spool, loweringthe possibility of large flowtransients in the circuit. It isadjusted by backing off lock-nuts and turning adjustingscrews inward to decreaserate of spool travel and out-ward to increase spool travelrate. See spool control modi-fications in model code.
Stroke Adjustment
Stroke adjustment limitsmovement of the mainstagespool. Backing off the jamnutand turning the adjustingscrew inward decreasesspool stroke. See spool con-trol modifications in modelcode.
Optional Features
Pilot Choke
Stroke Adjustment
Reducer ModuleDGMX2-3-PP-FW-S-40-EN91
The reducer module isrequired for piloted modelswhen pilot prerssureexceeds 210 bar (3000 psi).These two-stage spoolvalves maintain a reducedoutlet pressure against varia-tions in inlet pressure. Thesevalves are able to act asrelief valves (at 50% of themaximum flow) to preventexcess pressure being devel-oped when an actuator issubject to a reactive load.
Pressure Centered Models
This option provides fasterspring centering time byusing pilot pressure to centerthe spool. The centeringsprings are used in additionto pilot pressure to ensurepositive centering of thespool. The valve spool isreturned to center positionby pilot pressure and center-ing springs. If pilot pressurefails or falls below therequired minimum, the spoolwill return to center positionat minimum pilot pressureflow rates for pressure cen-tered valves.
Reducer
Pressure Centered Model
23EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
Integral Check Valves
For internal pilot pressure, anintegral pressure port checkvalve is required for internallypiloted valves with open cen-ter spools (0,1,4,8 & 9). Thepilot pressure generated isthe total of: P?T dropthrough the valve in centercondition, pressure dropthrough the check valve, plusthe pressure at the tank port.
For proper operation, totalpressure drop must begreater than the minimumrequired pilot pressure (seechart). To prevent load drop, acheck valve in the pressureport can be used to preventreverse flow from a cylinderport to pressure port. If usingas reverse flow check, maxi-mum reverse pressure is lim-ited to 210 bar (3000 psi).
X - Fast Response
Use of this option decreasesthe shift time and increasesthe system shock genera-tion. This requires theremoval of an orifice plugwithin the mainstage body. Itis available on all models byadding ‘‘X’’ to the modelcode. Example: DG5V-8-(*)-2C-X-(*)-10
When a standardperformance pilot isselected and pilot
pressure is above 3000 psi,the reducer module isrequired to limit high drainline pressure transients gen-erated during shifting.
0 20 40 60 80 100 120 140 160 180 200
75.7151.4
227.1302.8
378.5454.2
529.9605.6
681.3757.0
6,9
13,8
20,7
27,6
34,5
41,4
48,3
00
700
600
500
400
300
200
100
FLOW - USgpm
FLOW - L/min
rab - P
OR
D E
RU
SS
ER
P
isp - P
OR
D E
RU
SS
ER
P
ʻ̒ R ʼʼ Spring
ʻ̒ Sʼ̓ Spring
ʻ̒ Kʼ̓ Spring
ʻ̒ Qʼ̓ Spring
Pressure Drop Across Check Valve
Optional Features(continued)
24 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
DG5V-8 with Main Stage Spool Monitoring Switch “PC*” or “PD*” Models (LVDT Style Switch)
Millimeters (inches)
ElectricalInformation
MODEL ‘‘A’’ ‘‘F’’ ‘‘G’’CODE DIMENSION DIMENSION DIMENSION
DG5V-8-H/S-(B)-*A/B/C/F/N(L)-(*)-PCA/PDA-(*)-(V)M-*-10 135.6[5.34] 238.7[9.40] 371.3[14.62]DG5V-8-H/S-R-(B)-*A/B/C/F/N(L)-(*)-PCA/PDA-(*)-(V)M-*-10 175.6[6.91] 238.7[9.40] 371.3[14.62]DG5V-8-H/S-(B)-*A/B/C/F/N(L)-(*)-2-PCA/PDA-(*)-(V)M-*-10 175.6[6.91] 238.7[9.40] 371.3[14.62]DG5V-8-H/S-R-(B)-*A/B/C/F/N(L)-(*)-2-PCA/PDA-(*)-(V)M-*-10 215.6[8.49] 238.7[9.40] 371.3[14.62]DG5V-8-H/S-(B)-*A/B/C/F/N(L)-(*)-8-PCA/PDA-(*)-(V)M-*-10 135.6[5.34] 238.7[9.40] 446.6[17.58]DG5V-8-H/S-R-(B)-*A/B/C/F/N(L)-(*)-8-PCA/PDA-(*)-(V)M-*-10 175.6[6.91] 238.7[9.40] 446.6[17.58]DG5V-8-H/S-(B)-*A/B/C/F/N(L)-(*)-28-PCA/PDA-(*)-(V)M-*-10 175.6[6.91] 238.7[9.40] 446.6[17.58]DG5V-8-H/S-R-(B)-*A/B/C/F/N(L)-(*)-28-PCA/PDA-(*)-(V)M-*-10 215.6[8.49] 238.7[9.40] 446.6[17.58]DG5V-8-H/S-(B)-*A/B/C/F/N(L)-(*)-PCB/PDB-(*)-(V)M-*-10 135.6[5.34] 132.7[5.22] 371.3[14.62]DG5V-8-H/S-R-(B)-*A/B/C/F/N(L)-(*)-PCB/PDB-(*)-(V)M-*-10 175.6[6.91] 132.7[5.22] 371.3[14.62]DG5V-8-H/S-(B)-*A/B/C/F/N(L)-(*)-2-PCB/PDB-(*)-(V)M-*-10 175.6[6.91] 132.7[5.22] 371.3[14.62]DG5V-8-H/S-R-(B)-*A/B/C/F/N(L)-(*)-2-PCB/PDB-(*)-(V)M-*-10 215.6[8.49] 132.7[5.22] 371.3[14.62]DG5V-8-H/S-(B)-*A/B/C/F/N(L)-(*)-7-PCB/PDB-(*)-(V)M-*-10 135.6[5.34] 208.0[8.19] 446.6[17.58]DG5V-8-H/S-R-(B)-*A/B/C/F/N(L)-(*)-7-PCB/PDB-(*)-(V)M-*-10 175.6[6.91] 208.0[8.19] 446.6[17.58]DG5V-8-H/S-(B)-*A/B/C/F/N(L)-(*)-27-PCB/PDB-(*)-(V)M-*-10 175.6[6.91] 208.0[8.19] 446.6[17.58]DG5V-8-H/S-R-(B)-*A/B/C/F/N(L)-(*)-27-PCB/PDB-(*)-(V)M-*-10 215.6[8.49] 208.0[8.19] 446.6[17.58]DG5V-8-H/S-(B)-*A/B/C/F/N(L)-(*)-PCD-(*)-(V)M-*-10 135.6[5.34] 238.7[9.40] 477.3[18.79]DG5V-8-H/S-R-(B)-*A/B/C/F/N(L)-(*)-PCD-(*)-(V)M-*-10 175.6[6.91] 238.7[9.40] 477.3[18.79]DG5V-8-H/S-(B)-*A/B/C/F/N(L)-(*)-2-PCD-(*)-(V)M-*-10 175.6[6.91] 238.7[9.40] 477.3[18.79]DG5V-8-H/S-R-(B)-*A/B/C/F/N(L)-(*)-2-PCD-(*)-(V)M-*-10 215.6[8.49] 238.7[9.40] 477.3[18.79]DG5V-8-H/S-(B)-*D-(*)-PCB/PDB-(*)-(V)M-*-10 135.6[5.34] 193.5[7.62] 432.1[17.01]DG5V-8-H/S-R-(B)-*D-(*)-PCB/PDB-(*)-(V)M-*-10 175.6[6.91] 193.5[7.62] 432.1[17.01]DG5V-8-H/S-(B)-*D-(*)-2-PCB/PDB-(*)-(V)M-*-10 175.6[6.91] 193.5[7.62] 432.1[17.01]DG5V-8-H/S-R-(B)-*D-(*)-2-PCB/PDB-(*)-(V)M-*-10 215.6[8.49] 193.5[7.62] 432.1[17.01]
"F""G"
M12 Thread Connection
"A"
A Port
Side
B Port
Side
25EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
Signal 1
Signal 0 Signal 0
TYPICAL "PCA/PCB" OUTPUT (FOR SENSING CENTER POSITION)
Signal 0 = Voltage at pin 2/4 < 1.8VSignal 1 = Voltage at pin 2/4 > (Vs – 2.5V)
Signal 1
Signal 0 Signal 0
TYPICAL "PDA/PDB" OUTPUT (FOR FULL SHIFT SENSING)
Center Sw
itch Point
Switch Point
Full Stroke
Full Stroke
Signal 0 = Voltage at pin 2/4 < 1.8VSignal 1 = Voltage at pin 2/4 > (Vs – 2.5V)
Center
Switch Point
Switch Point
Full Stroke
Full Stroke
Signal 1
Signal 0 Signal 0
TYPICAL "PCD" OUTPUT (FOR CENTER SENSING 'A' PORT END, FULL SHIFT SENSING 'B' PORT END)
Signal 0 = Voltage at pin 2/4 < 1.8VSignal 1 = Voltage at pin 2/4 > (Vs – 2.5V)
Center
Switch Point
(Center Sensing)
Switch Point
(Center Sensing)
Full Stroke
Full Stroke
Switch Point
(Full Shift Sensing)
Switch Point
(Full Shift Sensing)
OSZILATOR DEMO-DULATOR
OVERLOADPROTECTED
OUTPUT
=
=
=
stab
=
=
24V ±20%
LR 1 =
Input
Output
Output
Ground
1
4
2
3
LR 2
R 1,R 2 = e.g. Coil Resistance of the switch relay >/= 60 OHMS L L
Electrical Schematic and Mating Connector Detail
SPECIFICATIONS
Supply Voltage (Vs) 24VDC ± 20%(Full Wave Bridge with Capacitor)Reverse Polarity Protection MAX. 300V InstalledRipple Voltage 10%Current Consumption 40mA Approx.Outputs NC Contact Positive
(No Short Circuite Protection)Sensing Distance (offset position) 5.85 to 6.15 mmSensing Distance (from center position) ± 0.35 to 0.65 mmHysteresis �0.06mmOutput Voltage
Signal 0 < 1.8VSignal 1 Vs – 2.5V
Output Current <400mA at Input +20%Environmental Protection IP65 (With Mounted Plug)Operating Temperature Range -20 ˚C to +85 ˚CMax. Operating Pressure 315bar [4500psi]CE Declaration of Conformity No. 00 02 002 9 93P-Channel, Contact PositiveATTENTION: EMC ONLY ENSURED WHEN USING SCREENED CABLES AND SCREENED PLUG CASING.
PIN #1Input Voltage (Vs)+24VDC±20%
PIN #4Output Voltage Signal(Vs - 2.5V)
PIN #3Ground
PIN #2Output Voltage Signal(Vs - 2.5V)
Connector Detail
DG5V-8 with Main Stage Spool Monitoring Switch “PC*” or “PD*” Models (LVDT Style Switch)
Millimeters (inches)
ElectricalInformation(continued)
26 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
DG5V-8 with Main Stage Spool Monitoring Switch“PPA”, “PPB” or “PPD” Models (Proximity Switch)
Millimeters (inches)
ElectricalInformation(continued)
MODEL ‘‘A’ ‘‘F’’ ‘‘G’’CODE DIMENSION DIMENSION DIMENSION
DG5V-8-H/S-(B)-*A/B/C/F/N(L)-(*)-PPA-(*)-(V)M-*-10 135.6[5.34] 186.2[7.33] 318.8[12.55]DG5V-8-H/S-R-(B)-*A/B/C/F/N(L)-(*)-PPA-(*)-(V)M-*-10 175.6[6.91] 186.2[7.33] 318.8[12.55]DG5V-8-H/S-(B)-*A/B/C/F/N(L)-(*)-2-PPA-(*)-(V)M-*-10 175.6[6.91] 186.2[7.33] 318.8[12.55]DG5V-8-H/S-R-(B)-*A/B/C/F/N(L)-(*)-2-PPA-(*)-(V)M-*-10 215.6[8.49] 186.2[7.33] 318.8[12.55]DG5V-8-H/S-(B)-*A/B/C/F/N(L)-(*)-8-PPA-(*)-(V)M-*-10 135.6[5.34] 186.2[7.33] 394.2[15.52]DG5V-8-H/S-R-(B)-*A/B/C/F/N(L)-(*)-8-PPA-(*)-(V)M-*-10 175.6[6.91] 186.2[7.33] 394.2[15.52]DG5V-8-H/S-(B)-*A/B/C/F/N(L)-(*)-28-PPA-(*)-(V)M-*-10 175.6[6.91] 186.2[7.33] 394.2[15.52]DG5V-8-H/S-R-(B)-*A/B/C/F/N(L)-(*)-28-PPA-(*)-(V)M-*-10 215.6[8.49] 186.2[7.33] 394.2[15.52]DG5V-8-H/S-(B)-*A/B/C/F/N(L)-(*)-PPB-(*)-(V)M-*-10 135.6[5.34] 132.7[5.22] 318.8[12.55]DG5V-8-H/S-R-(B)-*A/B/C/F/N(L)-(*)-PPB-(*)-(V)M-*-10 175.6[6.91] 132.7[5.22] 318.8[12.55]DG5V-8-H/S-(B)-*A/B/C/F/N(L)-(*)-2-PPB-(*)-(V)M-*-10 175.6[6.91] 132.7[5.22] 318.8[12.55]DG5V-8-H/S-R-(B)-*A/B/C/F/N(L)-(*)-2-PPB-(*)-(V)M-*-10 215.6[8.49] 132.7[5.22] 318.8[12.55]DG5V-8-H/S-(B)-*A/B/C/F/N(L)-(*)-7-PPB-(*)-(V)M-*-10 135.6[5.34] 208.0[8.19] 394.2[15.52]DG5V-8-H/S-R-(B)-*A/B/C/F/N(L)-(*)-7-PPB-(*)-(V)M-*-10 175.6[6.91] 208.0[8.19] 394.2[15.52]DG5V-8-H/S-(B)-*A/B/C/F/N(L)-(*)-27-PPB-(*)-(V)M-*-10 175.6[6.91] 208.0[8.19] 394.2[15.52]DG5V-8-H/S-R-(B)-*A/B/C/F/N(L)-(*)-27-PPB-(*)-(V)M-*-10 215.6[8.49] 208.0[8.19] 394.2[15.52]DG5V-8-H/S-(B)-*A/B/C/F/N(L)-(*)-PPD-(*)-(V)M-*-10 135.6[5.34] 186.2[7.33] 372.4[14.66]DG5V-8-H/S-R-(B)-*A/B/C/F/N(L)-(*)-PPD-(*)-(V)M-*-10 175.6[6.91] 186.2[7.33] 372.4[14.66]DG5V-8-H/S-(B)-*A/B/C/F/N(L)-(*)-2-PPD-(*)-(V)M-*-10 175.6[6.91] 186.2[7.33] 372.4[14.66]DG5V-8-H/S-R-(B)-*A/B/C/F/N(L)-(*)-2-PPD-(*)-(V)M-*-10 215.6[8.49] 186.2[7.33] 372.4[14.66]DG5V-8-H/S-(B)-*D-(*)-PPB-(*)-(V)M-*-10 135.6[5.34] 193.5[7.62] 379.7[14.95]DG5V-8-H/S-R-(B)-*D-(*)-PPB-(*)-(V)M-*-10 175.6[6.91] 193.5[7.62] 379.7[14.95]DG5V-8-H/S-(B)-*D-(*)-2-PPB-(*)-(V)M-*-10 175.6[6.91] 193.5[7.62] 379.7[14.95]DG5V-8-H/S-R-(B)-*D-(*)-2-PPB-(*)-(V)M-*-10 215.6[8.49] 193.5[7.62] 379.7[14.95]
"F""G"
M12 ThreadConnection
REVISIONS
"A"
ZONE REV DESCRIPTION DATE APPROVED
B JLH
A Port Side B Port Side
27EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
SENSOR
PIN 1
PIN 4
PIN 3
10K
POWER SUPPLY
SIGNAL OUTPUT
GROUND
Signal 1
Signal 0
TYPICAL "PPB" OUTPUT
Signal 0 = Voltage at pin 4 = 0VSignal 1 = Voltage at pin 4 > (Vs – 2.2V)
Full StrokeSwitch Point
Center
Signal 0 = Voltage at pin 4 = 0VSignal 1 = Voltage at pin 4 > (Vs – 2.2V)
Full StrokeSwitch Point
Center
TYPICAL "PPA" OUTPUT
Signal 1
Signal 0
Signal 0 = Voltage at pin 4 = 0VSignal 1 = Voltage at pin 4 > (Vs – 2.2V)
Full StrokeSwitch Point
Center
TYPICAL "PPD" OUTPUT
Signal 0
Signal 1
Full StrokeSwitch Point
Signal 0
Signal 1
Output Circuit Wiring Instructions
SPECIFICATIONS
Supply Voltage (Vs): 10 to 30 VdcSupply Current (ls): 8mA at 24Vdc (Plug Load Current)Supply Over-Voltage Rating: 35Vdc ContinuousSupply Reverse Polarity Rating: -35Vdc (With No Shorts)Short Circuit Tolerance: Continuous Short Between any Two PinsHigh Potential Test, Pin to Case: 300VdcElectromagnetic Compatibility: ISO 7637 Parts 0 and 1 Worst Case and Immunity to Radiated Electromagnetic
Fields, 10KHz to 1GHz per SAE J1113/25 SEP 95Pins to Case Resistance: > 50 MEGOHMSLoad Dump Tolerance: 80Vdc PEAK, 400ms Decay, with 1.5 OHM Source ImpedanceSwitching Frequency: 0 to 3K HzOutput: Open Collector PNP Sourcing, Normally OpenSensing Distance (offset position): 1.27 ± 0.25 mm (.050" ± .010") of Full StrokeHysteresis: 0.25 mm (.010") Max.Rise/Fall Time: 6.5/1.5 Microsec Rl = 820 OHM, Cl = 20 pF @ 8VdcOutput Leakage Current: 10 mA MaxOutput Voltage High: +Vs – 2.2Vdc MinOutput Load Current: 200mA MaxOperating Pressure: 350 bar (5000 psi) Operating Temperature: -40˚ to 110˚ CHumidity: 0% to 100%
ATTENTION: EMC ONLY ENSURED WHEN USING SCREENED CABLES AND SCREENED PLUG CASING.
PIN #2Not Used
PIN #3Ground
PIN #4Output Voltage Signal(Vs -2.2V)
PIN #1Input Voltage(Vs) 10 to 30VDC
Connector Detail
DG5V-8 with Main Stage Spool Monitoring Switch“PPA”, “PPB” or “PPD” Models (Proximity Switch)
Millimeters (inches)
ElectricalInformation(continued)
28 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
Valve for SafetyCircuit Application (35A Spool)
D
A
C
B
Main Stage Hydraulic SymbolA B
P T
MODEL A B C D LEAKAGE P-A FLOW CURVE
mm (in) mm (in) mm (in) mm (in) cc/min (in3/min)DG5V5-35A 118.5 (4.67) 234.7 (9.24) 262.1 (10.32) Available upon request Available upon requestDG5V7-35A 152.1 (5.99) 252.1 (9.92) 286.6 (11.28) Available upon request See DG5V7 catalogDG5V8-35A 151.7 (5.97) 346.0 (13.62) 380.5 (14.98) 156 (9.5) Available upon requestDG5V10-35A 230.7 (9.10) 443.4 (17.46) 476.3 (18.8) Available upon request Available upon request
DG5V with PPA Switch Option Shown
29EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
Typical SolenoidEnergizing
Solenoids identified to U.S.standards
Functional symbols related tosolenoid identity “A” and/or“B” according to NFPA/ANSIstandards, i.e. energizingsolenoid “A” gives flow P toA, solenoid “B” gives flow Pto B (as applicable).
Typical SolenoidEnergizing
Solenoids identified toEuropean standards (speci-fy “V” in model code)
Functional symbols related tosolenoid identity “A” and/or“B” according to Europeanconvention i.e. solenoid “A”adjacent to “A” port, solenoid
DG4V-3 HIGH PERFORMANCE SOLENOID COIL RATINGS
Solenoid Identification Letter Solenoid Voltage RatingBL 110V AC 50Hz
120V AC 60 HzDL 220V AC 50 Hz
240V AC 60 HzGL 12V DCHL 24V DC
DG4V-3(S) STANDARD PERFORMANCE SOLENOIDS COIL RATINGS
Solenoid Identification Letter Solenoid Voltage RatingA 110V AC 50HzB 110V AC 50 Hz
120V AC 60 HzC 220V AC 50 HzD 220V AC 50 Hz
240V AC 60 HzG 12V DCH 24V DC
Port APort P
Port TPort B
SolenoidB
SolenoidA
Port APort P
Port TPort B
SolenoidA
SolenoidB
SOLENOID FOR SPOOL TYPE SOLENOID
B All except “8” AA “8” only BFor valves with type “8” spools, solenoid identity to U.S. convention is the sameas for European convention.
POWER CONSUMPTION
AC solenoids Initial § Holding Initial § Holding(for coils listed in model code). VA (RMS) VA (RMS) VA (RMS) VA (RMS)Full power coils:
Single frequency coils AC 50 Hz 225 39 285 54Dual frequency coils at 50 Hz 265 49 280 61Dual frequency coils at 60 HZ 260 48 300 58
Low power coils, “BL” and “DL”:Dual frequency coils at 50 Hz Low power coils not usable 170 37Dual frequency coils at 60 Hz with DG4V-3S valves. 190 37
Power consumption, DC solenoids at rated voltage and 20 C (68 F).Full power coils:
12V, model type “G” 30W – 30W –24V, model type “H” 30W – 30W –
Low power coils:12V, model type “GL” Low power coils not usable 18W –24V, model type “HL” with DG4V-3S valves. 18 –
§ 1st half cycle; armature fully retracted.
ElectricalInformation(continued)
30 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
24,00(0.94)
Models for use with ISO 4400 (DIN 43650) connectorsMillimeters (inches)
Double solenoid models Single solenoid models DG4V-3(S)-*C-**-(V)M-U-**-60 DG4V-3(S)-*A(-**) DG4V-3(S)-*AL(-**) Solenoid andDG4V-3(S)-*N-**-(V)M-U-**-60 DG4V-3(S)-*B(-**) DG4V-3(S)-*BL(-**) end cap
DG4V-3(S)-8BL(-**) DG4V-3(S)-8B(-**) interchangedDG3V-3(S)-*F DG4V-3(S)-*FL(-**)
Asshown
Coil types: U (shown), KU, SP1,and SP2 (see Model Code)
A (double solenoid model)
87,0(3.42)
53,00(2.1)
B (single solenoid model)
21,75(0.86)
25,00(0.98)
100,0(4.0)
D 74,00(2.91)
48,00(1.88)
Alternative plug positions byloosening knurled nut, turningcoil, and re-tightening.
Port APort P
Port TPort B
C, coillength
3rd angleprojection
Water-resistant manual override on solenoid
DG4V-3(S)-****(L)-H-(V)M-**-**-60
Application
General use where finger operation is required (standardmanual overrides cannot be operated without using small tool).
Latching manual override on solenoid
DG4V-3-****(L)-Y-(V)M-**-**-60DG4V-3S-****(L)-Y-(V)M-**-**-60, DC coil models only
Application
Stainless steel lever/latch mechanism and water-resistant sealmake this feature ideal for vehicle-mounted and exposedapplications requiring emergency selection of valve for a peri-od of time in the event of electrical failure.
MODEL TYPE AC OR DC A DIM. B DIM. C DIM. D DIM.
All DC = 220 (8.66) 156 (6.14) 61 (2.5) 73 (2.87)DG4V-3 AC 200 (7.87) 146 (5.75) 51 (2.1) 63 (2.48)DG4V-3S AC 200 (7.87) 146 (5.75) 45 (1.7) 63 (2.48)
Note:“H” feature is not field convertible from other models; specify with order.
Spacer
15(0.6)
Overall length of valve withstandard manual overridesManual
actuation mustbe applied withinthis diameter:approximately20 (0.75).Spacer preventsactuation bylarger device.
Notes:1. Opposite solenoid (on “C” and “N” double solenoid models) should not be energized
while the valve is latched in selected position; AC solenoid coils will burn out underthis improper usage.
2. “Y” feature is field-convertible from “H” type manual override (omitting spacer), but isnot field-convertible from other models.
Overall length of valve withstandard manual overridesLever in latched position
Lever in free position
Push lever tooperate valve;latch holds lever inoperated position
Lift latch torelease lever
65(2.5)
40(1.6)
Models for use with ISO 4400 (DIN 43650) connectors
Millimeters (inches)
• Not applicable to type “8” spool.§ Can vary dependent on source of plug.
ElectricalInformation(continued)
31EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
47(1.85)
Groundconnection4,0 (0.16 dia.)self–tappingscrew
Double solenoid models Single solenoid models DG4V-3(S)-*C-**-(V)M-F-**-60 DG4V-3(S)-*A(-**) DG4V-3(S)-*AL(-**) Solenoid andDG4V-3(S)-*N-**-(V)M-F-**-60 DG4V-3(S)-*B(-**) DG4V-3(S)-*BL(-**) end cap
DG4V-3(S)-8BL(-**) DG4V-3(S)-8B(-**) interchangedDG3V-3(S)-*F DG4V-3(S)-*FL(-**)
Asshown
Two leadwires per
solenoid withM3 size
terminals forcustomer
connections
24,00(0.94)
25,00(0.98)
3,0(0.12)
*J & W conduit boxes
Thread connection“W” – NPT“J” – M20 × 1.5-8H
91,00(3.57)
21,75(0.86)
48,00(1.88)
50,00(2.0)
A (double solenoid models)
B (single solenoid models)
C coillength
D74,00(2.91)
68,75(2.71)
53,00(2.1)
Port APort P
Port TPort B
* 89 (3.5) for FPB – J & W conduit boxes104 (4.0) All plug-in conduit boxes
Models with “F” type coils (lead wires) and conduit box.
Millimeters (inches)
MODEL TYPE AC OR DC A DIM. B DIM. C DIM. D DIM.
All DC = 220 (8.66) 156 (6.14) 61 (2.5) 73 (2.87)DG4V-3 AC 200 (7.87) 146 (5.75) 51 (2.1) 63 (2.48)DG4V-3S AC 200 (7.87) 146 (5.75) 45 (1.7) 63 (2.48)
• Not applicable to type “8” spool.
Codes “FJ” and “FW”: 2 lead wires for each solenoid, approximately 150,00 (6.00) long. M3 (#6) terminals provided for customer connection.Codes for “FTJ” and “FTW” Valve supplied with lead wires connected into terminal strip suitable for M3 (#6) terminals for customer connection.
ElectricalInformation(continued)
32 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
248,2 (9.8) with DC solenoid238,2 (9.4) with AC solenoid
DG4V-3-*A(L)-(V)M-S6-U-**-60Millimeters (inches)
Single solenoid models with LVDT typeswitch indicating when the spool is in thespring off-set position. ISO 4400 (DIN43650) connection to solenoid;Pg7 connection to switch.
For coil removal:64 (2.51) DC coil54 (2.12) AC coil
138,2 (5.44)
Location of solenoidfor RH build models
Location of switchfor RH build models Plug (part no. 458939)
supplied with valve
Cable gland PG7:6,0 (0.24) dia.
Pin number 2, supply +ve
Pin number 3, 0V Pin number 1,“normally open”
Pin number 4,“normally closed”
For LH build (DG4V-3-*AL)solenoid and switch locationsare reversed.
DG4V-3-*A(L)-(V)M-S6-U-**-60
Millimeters (inches)
Single solenoid models with LVDT type switch indicatingwhen the spool is in the spring off-set position. ISO 4400(DIN 43650) connection to solenoid; Pg7 connection toswitch.
DG4V-3-*A(L)-(Z)-(V)M-S3-FPA5W-*2-60DG4V-3-*A(L)-(Z)-(V)M-S4-FPA5W-*2-60DG4V-3-*A(L)-(Z)-(V)M-S5-F-*2-60Single solenoid models with mechanical type switchmonitoring of spool movement.
Conduit box with leads, or pre-wired to NFPAT3.5.29-1980 receptacle.
For LH build (DG4V-3-*AL)solenoid and switch locations are reversed. 200 (7.87) with AC solenoid
210 (8.27) with DC solenoid
100 (3.94)
Location of switch and housingfor RH build models
Normally closed lead (Monitor switch)sleeving identification color white.Common lead (Monitor switch)sleeving identification color black.
Normally open lead (Monitor switch)no color identification.
Location of solenoidfor RH build models
54 (2.12)for removalof switch hsg.
See page 15 for details of connections to pre-wired 5-pin receptacle for:“S3” normally open and“S4” normally closed.
DG4V-3-*A(L)-(Z)-(V)M-S3-FPA5W-*2-60DG4V-3-*A(L)-(Z)-(V)M-S4-FPA5W-*2-60DG4V-3-*A(L)-(Z)-(V)M-S5-F-*2-60
Single solenoid models with mechanical typeswitch monitoring of spool movement.Conduit box with leads, or pre-wired to NFPAT3.5.29-1980 receptacle.
Port restrictor plugs
Restrictor plugs are availablefor use in ports P, T, A or B.These can be used forrestricting flow or for circuitdampening. Restrictor plugsare not recommended foruse above 210 bar (3000 psi)system pressure.
Typical model codes:DG4V-3(S)-**-M-**-**-60-P08(0.8 mm dia orifice in port P)
DG4V-3(S)-**-M-**-**-60-P10-A10 (1.0 mm dia orifice inports P and A)
RESTRICTOR PLUG SELECTION TABLE
Code Orifice Partdiameter number§
*00 Blank 694353*03 0,30 (0.012) 694341*06 0,60 (0.024) 694342*08 0,80 (0.030) 694343*10 1,00 (0.040) 694344*13 1,30 (0.050) 694345*15 1,50 (0.060) 694346*20 2,00 (0.080) 694347*23 2,30 (0.090) 694348* = P, T, A or B, as required§ Available in multiples of 25 per part number
Maximum port dia in subplate/manifoldblock:For steel and SG (ductile) iron: 7,0 (0.3)For gray iron: 6,5 (0.25)
M5 x 0.8-6H threadfor plug extraction
ElectricalInformation(continued)
33EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
For valves with type “F” coils.Millimeters (inches)
1. For DC coils the +ve lead(s) must be connectedto the terminal(s) marked +. When using 3-wireincoming leads to double solenoid valves (i.e.common neutral) the inner pair of terminals mustbe interconnected
2. For correct light indication of energized solenoidensure that solenoid leads are correctly connected:light terminals are common with each outer pair ofsolenoid terminals according to the side with + mark.
Terminal strip(part number
890345) clips tocover and can
be field-fitted
M3 x 0,5-6H screws(part number 186006)
2 each end
4 terminal screws M3 x 0,5-6H (part number 02-113355)
Connections to solenoid A(or B, according to model type)
Connections tosolenoid B
(or A, accordingto model type)
Rubber gasket
Conduit box cover andnameplate complete withsealing gasket and 4 screws
Anti-rotation tab ensurescorrect orientation of coverto junction box
28,50(1.12)
30,00(1.18)
Light assembly is held in placeby end pair of M3 screws; canbe fitted to terminal strip.
2 lenses in cover
Terminal Strip and Lights
Insta-Plug
DG4V-3(S)---FPA---60 DG4V-3(S)---FPBW---60
Eaton 2-part “Insta-Plug”eliminates breaking electricalinputs for valve disconnect. Amale half is pre-wired to thevalve body. The mating plug
is inside a wire housing withexternal terminals formachine wire connections.
Captive thumb screws, whenloosened, permit the wirehousing to be pulled clear ofthe valve for disconnect. Alonger ground post provides
first make/last break groundconnection.
The PBW configuration com-bines both male and femaleplugs in the wiring housingfor a self-contained plug-inunit.
Optional solenoid indicatorlights are pre-wired to thefemale plug. Solenoids “A”and/or “B” are identified onthe wiring housing.
24,0(0.95)
PA configurationMillimeters (inches)
PBW configuration
71,1(2.80)
16,25(0.64)
47,5(1.87)
ref.
Port A Port BPort A Port B
15,5(0.61)
20,25 (0.79)
32,50(1.28)
M4-6H thd.
48,0(1.89)
89,0(3.50) Ground connection
in terminal box (ref.)
WARNING TAG“Electrical powermust bedisconnectedbefore removingor replacing thisreceptacle”.
Customer connection solenoid atport A end of body to femalereceptacle plate
Customer connectionsolenoid at port B end ofbody to femalereceptacle plate
69,0(2.72)
ref.
98,5(3.88)
23,1(0.91)
Clearance to removefemale receptacle
The conduit box dimensions used for the PA/PBW type connector are different from those on the other “F” type coil models.
ElectricalInformation(continued)
34 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
3 pin connectorUse with single solenoid valveKey model code designations:DG4V-3(S)-*A(L)(-**)-(V)M-FPA3W(L)DG4V-3(S)-*B(L)(-**)-(V)M-FPA3W(L)
5 pin connectorUse with single solenoid valve with S3spool position monitor switchKey model code designations:DG4V-3-*A(L)(-**)-(V)M-S3-FPA5W(L)
5 pin connectorUse with single solenoid valveKey model code designations:DG4V-3(S)-*A(L)(-**)-(V)M-FPA5W(L)DG4V-3(S)-*B(L)(-**)-(V)M-FPA5W(L)
68,75(2.71)
16,00(0.62)
0.875-16UN-2A thd.
41
2 3
54 – lead tosolenoid A
1 – lead to solenoid B
3 – green lead (ground)
5 – lead tosolenoid B
2 – lead to solenoid A
12
3
25,4 (1.00) hex(reference all types)
3 – lead to solenoid
1 – green lead (ground)
2 – lead to solenoid
41
2 3
54 – lead to monitorswitch, n.o.
1 – lead to solenoid 5 – lead tosolenoid
41
2 3
5
1 – lead to solenoid
3 – green lead (ground)
5 – lead to solenoid
41
2 3
54 – lead capped
1 – lead tosolenoid
3 – green lead (ground)
5 – lead tosolenoid
2 – lead capped
Warning tag:“Electrical power must bedisconnected before removingor replacing electrical plug.“
5 pin connectorUse with double solenoid valve Key model code designations:DG4V-3-*C/N(L)(-**)-(V)M-S4-FPA5W(L)
5 pin connectorUse with single solenoid valve with S4spool position monitor switchKey model code designations:DG4V-3-*A(L)(-**)-(V)M-S4-FPA5W(L)
4 – lead to monitor switch, n.c.
NFPA Connector T3.5.29-1980Connection details and model type/model code references.Millimeters (inches)
DG4V-3(S)---FPA3W(L)-**-60DG4V-3(S)---FPA5W(L)-**-60DG4V-3---S3-FPA5W(L)-**-60DG4V-3---S4-FPA5W(L)-**-60
The receptacle is a standard three orfive pole connector with shortened leadsand terminals added. The five pole plughas four leads 101,6 (4.0) long and one177,8 (7.0) long. The three pole plughas two leads 101,6 (4.0) long and one177,8 (7.0). All wires have underwritersrecognized non-solder insulated eyeletterminals. The green wire is used for theground (earth) connection (No. 8 screwfurnished). Valves are suppliedpre-wired.
NFPA Connector T3.5.29-1980
Connection details and model type/model codereferences.
Millimeters (inches)
DG4V-3(S)---FPA3W(L)-**-60DG4V-3(S)---FPA5W(L)-**-60DG4V-3---S3-FPA5W(L)-**-60DG4V-3---S4-FPA5W(L)-**-60
The receptacle is a standard three or five poleconnector with shortened leads and terminalsadded. The five pole plug has four leads 101,6(4.0) long and one 177,8 (7.0) long. The three poleplug has two leads 101,6 (4.0) long and one177,8 (7.0). All wires have underwriters recog-nized non-solder insulated eyelet terminals. Thegreen wire is used for the ground (earth) connec-tion (No. 8 screw furnished). Valves are suppliedpre-wired.
ElectricalInformation(continued)
35EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
DIN 43650 Connector
Cable diameter range Ø6–10 mm (0.24–0.40). . . Wire section range Ø,5–1,5 mm2 (0.0008–0.0023 in2). . . . . . Terminals Screw type. . . . . . . . . . . . . . Type of protection IEC144 class IP65, when plugs are fitted correctly to . . . . . .
the valves with interface seals (supplied with plugs) in place.
Voltage(AC or DC) Gray –
“A” sol.Black –“B” sol.
12-24100-125200-240
977467977469977471
977466977468977470
710775710776U1 Coilswithout lights
U6 Coilswith lights
ReceptacleSeal
51 (2.01)27
(1.06)
22,5(0.88)
∅
M3thread 5,5
(0.22)
1,5(0.06)
30,5 sq.(1.20)
26,5(1.04)27,5
(1.08)
18 sq.(0.71)
Part Numbers
U11 Rectifiedcoils withlights
12 DC 02-14135824 DC 02-14135998-240 VDC 02-141360200-240 VDC 02-141361
U12 Rectifiedcoils withoutlights
02-141357
DIN 43650 ConnectorMillimeters (inches)
Surge Suppression Devices(For DC Valves)
Connector can be positioned at 90intervals on valve by re-assemblingcontact holder into appropriateposition inside connector housing.
Use U12 or U11 type connectors with12 and 24V DC coils if rectification isrequired.
Connectors with and without indicatorlights are available (order separately):
Standard diodeDiode in parallel with coil. When switch(S1) is opened, the energy stored in thecoil is trapped and dissipated by thediode (D1).
D Works only with DC voltage
D Polarity dependent
D Increases drop out time
TranszorbDiode and Zener diode in parallel withcoil. When switch (S1) is opened, theenergy stored in the coil is trapped anddissipated by the diode (D1) and Zenerdiode (Z1) and the coil resistance.
D The Zener makes exact limitation ofinductive spikes.
D Works only with DC voltage
D Polarity dependent
S1D1 (No 2)
(No 1)
S1
D1
(No 2)
(No 1)
Coil Coil
NOTE: These surge suppressiondevices are “Polarity Dependent.” Properbiasing conditions must be met wheninstalling/connecting a coil in a system.
Shift Dropout
CETOP 3
No Diode 23 60 Diode Alone 23 141 Diode/Zener 23 78
CETOP 5
No Diode 70 50 Diode Alone 70 158 Diode/Zener 70 100
Times represent cessation/applicationof voltage to coil versus velocity(start/stop) of a cylinder using a singlesolenoid, spring offset valve (time inmilliseconds).
Valve Shift and Dropout TimesWith and Without Surge Suppression
ElectricalInformation(continued)
36 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
Mounting Surface
Subplates
Subplates must be orderedseparately. When a subplateis not used, a machined padmust be provided for mount-ing. Pad must be flat within0,13 mm (.0005 inch) andsmooth within 0,8 mm (32microinch).
Note
‘‘E’’ in subplate model codedesignates side ported models.
SUBPLATEMODEL CODE THREAD SIZE
DGVM-8-10-T12 1.062’’-12UNDGVM-8-10-T16 1.312’’-12UNDGVM-8-10-T20 1.625’’-12UNDGVME-8-10-T12 1.062’’-12UNDGVME-8-10-T16 1.312’’-12UNDGVM-8-D-10-T12 1.062’’-12UNDGVM-8-D-10-T16 1.312’’-12UN
Mounting Bolts
Mounting bolts not includedwith subplate mountedvalves or subplates for thosevalves. Bolts used should begrade 7 or better. Order kitsto obtain correct bolts:MOUNTING BOLT KITS
Metric BKDG8-655MInch BKDG06-635
Application Data
Fluid Cleanliness
Proper fluid condition isessential for long and satis-factory life of hydraulic com-ponents and systems.Hydraulic fluid must have thecorrect balance of cleanliness,materials, and additives forprotection against wear ofcomponents, elevated viscosi-ty, and inclusion of air.
Essential information on thecorrect methods for treatinghydraulic fluid is included inEaton publication 561“Vickers Guide to SystemicContamination Control” avail-able from your local Eatondistributor or by contactingEaton, Incorporated.
Recommendations on filtra-tion and the selection ofproducts to control fluid con-dition are included in 561.
Recommended cleanlinesslevels, using petroleum oilunder common conditions,are based on the highestfluid pressure levels in thesystem and are coded in thechart below. Fluids otherthan petroleum, severe serv-ice cycles, or temperatureextremes are cause foradjustment of these cleanli-ness codes.
Eaton products, as any com-ponents, will operate withapparent satisfaction in fluidswith higher cleanliness codesthan those described. Othermanufacturers will often rec-ommend levels above those
specified. Experience hasshown, however, that life ofany hydraulic component isshortened in fluids with high-er cleanliness codes thanthose listed below. Thesecodes have been proven toprovide a long, trouble-freeservice life for the productsshown, regardless of themanufacturer.
Fluids and Seals
The use of synthetic, fireresistant fluids requires avalve with special seals. Addprefix ‘‘F3’’ to the modelcode when phosphate esteroil or its blend are to beused. Add prefix ‘‘F6’’ to themodel code when water gly-col or water-in-oil emulsionsare to be used.
The pilot valve has ‘‘F3’’seals (Viton ) as standard. Allinternal seals of the main-stage are also ‘‘F3’’.Mounting face seals arestandard (Buna-N). ‘‘F6’’ pre-fix denotes special seals(Nitrile) throughout the valveassembly.
Fluid Cleanliness Rating
20/18/15
Viscosity Range
75 to 600 Ssu (15 to 128 cSt)
Operating TemperatureRange
–18 to 66 C (0 to 150 F)
25,4 (1.00)
180,9 (7.12)
130,2 (5.12)
112,7 (4.43)
94.4 (3.71) 53,2(2.09)
29,4 (1.15) 5,5 (0.22)
ʻ̒ Tʼ̓ - Tank connection
ʻ̒ Pʼ̓ - Pressure connection
ʻ̒ Yʼ̓ - ExternalPilot pressureconnection - DG3VPilot drainconnection - DG5V 4,7 (0.18)
19,0 (0.75) 92,1
(3.62)
ʻ̒ Bʼ̓ - Port connection
0.500-13 UNC-2Bthread 6 places
ʻ̒ Aʼ̓ Port connection100,8(3,96)
77,0(3.03)
29,4(1.15)
17,5(0.68)
∅ 7,0 (0.27)2-places
ʻ̒ Xʼ̓ - External pilotpressure connection
∅ 10,7 (0.42)
ʻ̒ Wʼ̓ port required forpressure centeredmodels. Use subplateDGVM-8-D-10-T*.
73,0(2.87)
46,0(1.81)
∅ 10,3 (0.40)4-places
35,0 (1.37)
17,5 (0.69)
74,6(2.94)
37EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC005-E March 2007
Released AssemblyNumbers of Valvewith Main SpoolMonitoring Switch
5996946-001 DG5V-8-H-0A-PCB-M-FW-B-105996963-001 DG5V-8-H-2A-PCA-T-M-U-H-105996947-001 DG5V-8-H-2A-PCB-M-FW-B-105996964-001 DG5V-8-H-2A-PCD-T-M-U-H-105996965-001 DG5V-8-H-2A-PDA-T-M-U-H-105996948-001 DG5V-8-H-2A-PDB-M-FW-B-105996966-001 DG5V-8-H-2A-PPA-T-M-U-H-105996967-001 DG5V-8-H-2A-PPD-T-M-U-H-105996949-001 DG5V-8-H-2B-PCB-M-FW-B-105996950-001 DG5V-8-H-2B-PDB-M-FW-B-105996968-001 DG5V-8-H-2C-PCA-T-M-U-H-105996969-001 DG5V-8-H-2C-PCD-T-M-U-H-1002-395827 DG5V-8-H-2C-PDA-E-M-U-H-105996970-001 DG5V-8-H-2C-PDA-T-M-U-H-105996971-001 DG5V-8-H-2C-PPA-T-M-U-H-105996972-001 DG5V-8-H-2C-PPD-T-M-U-H-1002-397613 DG5V-8-H-2N-2-PPD-M-U-H-10
5996951-001 DG5V-8-H-3C-PCB-M-FW-B-105996952-001 DG5V-8-H-6C-PCA-E-M-U-H-105996953-001 DG5V-8-H-6C-PCA-M-U-B-105996973-001 DG5V-8-H-6C-PCA-T-M-U-H-105996974-001 DG5V-8-H-6C-PCD-T-M-U-H-1002-395828 DG5V-8-H-6C-PDA-E-M-U-H-105996954-001 DG5V-8-H-6C-PDA-E-M-U-H-105996975-001 DG5V-8-H-6C-PDA-T-M-U-H-105996976-001 DG5V-8-H-6C-PPA-T-M-U-H-1002-397712 DG5V-8-H-6C-PPD-E-M-U-H-105996977-001 DG5V-8-H-6C-PPD-T-M-U-H-105996955-001 DG5V-8-H-8C-PCB-X-E-VM-FTWL-N-1002-397618 DG5V-8-H-B-2C-Z-PCB-E-VM-U-H-105996956-001 DG5V-8-H-B-2C-Z-PCB-E-VM-U-H-1002-397160 DG5V-8-H-B-35A-Z-PPA-E-VM-U-H-10-EN600
ASSEMBLY NUMBER MODEL CODE
ASSEMBLY NUMBER MODEL CODE
Size D08/NG25
© 2007 Eaton CorporationAll Rights Reserved Printed in USADocument No. V-VLDI-MC005-E Supercedes 5007.02/EN/1197/AMarch 2007
Eaton14615 Lone Oak RoadEden Prairie, MN 55344USATel: 952 937-9800Fax: 952 974-7722www.hydraulics.eaton.com
EatonDr.-Reckeweg-Str. 1D-76532 Baden-BadenGermanyTel: (49) 7221 682-0Fax: (49) 7221 682-788
Eaton20 Rosamond RoadFootscrayVictoria 3011AustraliaTel: (61) 3 9319 8222Fax: (61) 3 9318 5714