physics of ventilation
DESCRIPTION
by the renowned pediatrician, Dr Satish Deopujari, National Chairperson (Ex) Intensive Care Chapter I A P Founder Chairman..... National conference on pediatric critical care Professor of pediatrics ( Hon ) JNMC:Wardha Nagpur : INDIATRANSCRIPT
![Page 1: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/1.jpg)
Physics of Ventilation
National Chairperson (Ex)
Intensive Care Chapter I A P
Founder Chairman.....
National conference on pediatric critical
care
Professor of pediatrics ( Hon )
JNMC:Wardha
Nagpur : INDIA
Dr Deopujari
![Page 2: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/2.jpg)
The evolution of Ventilator
![Page 3: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/3.jpg)
Three problems of ventilation
![Page 4: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/4.jpg)
![Page 5: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/5.jpg)
![Page 6: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/6.jpg)
![Page 7: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/7.jpg)
Applied Physics
• Compliance
• Static compliance
• Dynamic compliance
• Resistance
• Work of breathing
Flow
Pressure
Volume
Surface area
What can we manipulate ?
![Page 8: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/8.jpg)
Evolution of Ventilators………………
What can we manipulate ?
1)Minute ventilation
2)Pressure gradient
3)Surface are
4)Pulmonary vasculature
5)Solubility
How can we do this ?
![Page 9: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/9.jpg)
Compliance
Compliance is a quotient between volume
and corresponding pressure change.
C =
V
P
Dynamic compliance
Static compliance
![Page 10: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/10.jpg)
The compliance of any structure is the ease is
with which the structure distends ( C= ∆ V / ∆ P)
C
O
M
P
L
I
A
N
C
E
![Page 11: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/11.jpg)
C.C.P.
C.O.P.
V O L U M E
PRESSURE
c.c.p. = critical closing pressure c.o.p. = critical opening pressure
PEEP
![Page 12: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/12.jpg)
Pressure
Volume
Optimal Benefit Of PEEP
EX. INS.
![Page 13: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/13.jpg)
Peak pressure
Plateau pressure Pressure
Inspiratory pause
Flow
Time
Cst = Tidal volume.
Cc
Cst : static compliance
Cc : circuit compliance
end expiratory pressure (Pend-ex)
Pend-ex = Peep + P peep
Resistance
Compliance
Static compliance
Static pressure – end expiratory pressure
![Page 14: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/14.jpg)
Flow …………………….
Flow indicates circulation of an element
per unit of time through a given place
Flow….
Linear
Turbulent
![Page 15: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/15.jpg)
FLOW
Palv
Pmo
FLOW THROUGH A PIPE LIKE
STRUCTURE REQUIRES A
DRIVING PRESSURE (Palv-
Pmo) TO OVERCOME THE
FRICTIONAL RESISTANCE
FLOW DEPENDS ON
Pressure Difference and
Resistance V=P/R
![Page 16: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/16.jpg)
Pressure …………….
Represents the force that a volume of gas exercises upon a unit
area.
Kinetic theory states that gas molecules bomb the walls of a
container .
If volume remains constant , pressure varies in direct proportion
to Temperature.
If temperature remains constant , pressure varies in inverse
relation to Volume .
Increase in pressure decreases volume
![Page 17: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/17.jpg)
Resistance ……………
Resistance is defined as the relationship between pressure (p) and flow ( 0 )
Therefore important when there is air flow.
R = -----------
Resistance depends upon
Diameter of airway
Length of airway
Viscosity and density of air
Resistance during inspiration
Resistance during expiration
P
O
![Page 18: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/18.jpg)
And how can we do this ?
![Page 19: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/19.jpg)
• Conditional variables
• Control variables
• Phase variables
Trigger variables
Limit variables
Cycle variables
Base line
Mechanical Ventilation
Concept
![Page 20: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/20.jpg)
Conditional variables alone or in combination are
analyzed by Ventilator’s control logic. The state of this variable determines as to which of
two types of breath would be delivered.
SIMV is based on timing window and accordingly the
ventilator delivers …………………………….
a pressure triggered ( patient ) or time triggered
( machine) breath.
In this situation the patient effort and time are
conditional variables for determining triggering.
CONDITIONAL
VARIABLE
Conditional variables
• Pressure
• Volume
• Flow
• Time
![Page 21: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/21.jpg)
Control variable manipulates the conditional to cause inspiration.
Pressure , volume , flow and time are control variables.
The behavior of control Variable remains constant in spite of changed
Ventilatory load.
CONRTOL VARIALBE
![Page 22: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/22.jpg)
Control variable manipulates the conditionals to cause inspiration.
PRESSURE , VOLUME , FLOW and time are control variables.
The behavior of control Variable remains constant in spite of changed
Ventilatory load.
CONRTOL VARIALBE
Pressure
Rectangular Exponential
![Page 23: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/23.jpg)
Control variable manipulates the conditional to cause inspiration.
Pressure , VOLUME , FLOW and time are control variables.
The behavior of control Variable remains constant in spite of changed
Ventilatory load.
Volume
Ramp Sinusoidal
CONRTOL VARIALBE
![Page 24: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/24.jpg)
Control variable manipulates the conditional to cause inspiration.
PRESSURE , VOLUME , FLOW and time are control variables.
The behavior of control Variable remains constant in spite of changed
Ventilatory load.
Flow
sinusoidal rectangle ramp
ramp exponential
CONRTOL VARIALBE
![Page 25: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/25.jpg)
During pressure support ventilation
though one selects a level of support
the Inspiration continues till
predetermined flow rate or termination
criteria is reached.
During PSV patient determines the
Rate ……………..
Inspiratory time…
Flow……………..
LIMIT
VARIBALE
![Page 26: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/26.jpg)
Peak pressure
Plateau pressure Resistance
Compliance
End of inspiration
Volume
Flow
Pressure
Volume control
![Page 27: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/27.jpg)
End of insp. flow
Volume
Flow
Pressure
Pressure control
What does not change …….
1)Volume curve
2)Exp. Flow curve
![Page 28: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/28.jpg)
End of insp. flow
Volume
Flow
Pressure
Pressure control
Peak p. Plateau p. Resist.
Compliance
End of insp. flow
Volume
Flow
Pressure
Volume control
![Page 29: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/29.jpg)
Volume limited and pressure limited ventilation ………….
Volume limited pressure limited
Advantages
Tidal Volume guaranteed
Precise control of Inspiratory flow
Easy detection of changed
respiratory impedance
Precise control pf pressure
Decelerating flow reported to
improve distribution of ventilation
decrease dead space ventilation
decrease PIP
match Inspiratory flow
Disadvantages
PIP vary
Inspiratory flow may not match the
patients needs
Variable tidal volume
Changes in impedance not easily
detected
![Page 30: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/30.jpg)
Modes of ventilation
or moods of ventilation
![Page 31: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/31.jpg)
P
R
E
S
S
U
R
e
F
L
O
w
V
O
L
U
M
e
A B C
A normal lung B decreased compliance C increased resistance
Controlled Ventilation…………….
![Page 32: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/32.jpg)
SIMV
Patient triggered ventilation
Synchronized to patient breath
if the threshold is met .
Patient controlled variables
Respiratory rate
Inspiratory time
Clinician controlled variables
PIP if pressure limited
Tidal volume if volume cycled
Inspiratory time if time cycled
Flow
SIMV rate
Flow cycling …….
Insp. Terminated at % of peak
flow rather than time…………
Synchronizes expiratory and
Insp. flow thus total synchrony
achieved.
![Page 33: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/33.jpg)
When SIMV is used, the patient receives three different types of breath:
The controlled (Mandatory) breath.
Assisted (synchronized) breaths.
Spontaneous breaths, which can be pressure supported.
A B C
A .Controlled and time triggered
B .Spontaneous
C .Synchronized and assisted
Flow
PaW
Volume
Trigger
![Page 34: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/34.jpg)
Spontaneous
breath Assisted breath
Back up ventilation period
Controlled breath
Spontaneous
volume
Trigger
Spontaneous
breath
Pressure
Volume
![Page 35: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/35.jpg)
![Page 36: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/36.jpg)
Pressure support
Pressure support ventilation is a spontaneous mode
of ventilation.
Inspiratory effort is assisted by the ventilator at an
airway pressure that remains constant during the
phase of inspiration.
Inspiration is terminated when the peak Inspiratory
flow reaches a preset level. (usually 25%)
Patient determines………………
• Rate
• Inspiratory time
• Airflow
![Page 37: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/37.jpg)
![Page 38: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/38.jpg)
PRVC
A control mode, which
delivers a set tidal volume with
each breath at the lowest
possible peak pressure.
Delivers the breath with a
decelerating flow pattern that is
thought to be less injurious to
the lung……
![Page 39: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/39.jpg)
Volume Support
Equivalent to pressure support
set a “goal” tidal volume
the machine watches the delivered
volumes and adjusts the pressure
support to meet desired “goal” within limits set by you.
![Page 40: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/40.jpg)
Airway Pressure Release Ventilation
Can be thought of as giving a patient
two different levels of CPAP
Set “high” and “low” pressures with
release time.
Length of time at “high” pressure
generally greater than length of time at
“low” pressure.
By “releasing” to lower pressure, lung
volume is allowed to decrease to FRC
![Page 41: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/41.jpg)
Certain other issues
![Page 42: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/42.jpg)
Fixed insp. Time
Termination sens. off Termination sens. on
Flow
Pressure
![Page 43: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/43.jpg)
Inspiratory cycle off…………
Proper Inspiratory cycle termination
avoids lung hyperinflation and
Increased work of breathing
40 %
10 %
10 %
5%
1%
![Page 44: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/44.jpg)
![Page 45: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/45.jpg)
PEEP PIP
Vt.
COMPLIANCE LINE
Pressure limited…
Over distension
![Page 46: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/46.jpg)
PEEP PIP
Vt.
COMPLIANCE LINE
Pressure limited…
PEEP PIP
Vt.
COMPLIANCE LINE
Volume limited…
Pressure – Volume loops
Low
compliance
![Page 47: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/47.jpg)
A
B C
D
Volume
Pressure in CM
B C
Volume
Pressure in CM A
D
Normal resistance
Increased resistance
![Page 48: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/48.jpg)
volume
Pressure
![Page 49: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/49.jpg)
Triggering ……………………
![Page 50: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/50.jpg)
Triggering ……………………
Neuro – Ventilatory coupling ………….
Central Nervous System
Phrenic Nerve
Diaphragmatic contraction
Chest Wall and Lung expansion
Air way pressure , flow and volume
NAVA Ventilator
Current
Technology
Ideal technology
Neurally Adjusted
Ventilatory Assist
EA di
Waveform
![Page 51: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/51.jpg)
Tidal volume ÷ P plat – PEEP Tidal volume ÷ PIP – PEEP PIP – P plat ÷ Flow rate PIP- P2 ÷ Flow rate
Static compliance
Dynamic
characteristics Maximum resistance
index
Minimum resistance
index
Elastic and resistive
property of respiratory
System
Time constant
×
Resistive property
![Page 52: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/52.jpg)
Conditional variables
Control variables
Pressure : Volume : Flow
Phase Variables
Trigger : Limit : cycle : Base line
![Page 53: Physics of Ventilation](https://reader033.vdocuments.site/reader033/viewer/2022052523/556480cad8b42a361d8b4a21/html5/thumbnails/53.jpg)
You can comfortably SLEEP even in difficult situation
if you know your physiology well……………
Thanks
SLEEP