photovoltaic inverter & storage solutions – summary · solutions – summary photovoltaic...

12
SOLUTIONS – SUMMARY PHOTOVOLTAIC INVERTER & STORAGE

Upload: others

Post on 15-Mar-2020

31 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PHOTOvOlTAIC InvERTER & STORAGE SOLUTIONS – SUMMARY · solutions – summary photovoltaic inverter & storage. fimer technology park fimer factory. metal works dpt. headquarter automatic

SOLUTIONS – SUMMARYPHOTOvOlTAIC InvERTER & STORAGE

Page 2: PHOTOvOlTAIC InvERTER & STORAGE SOLUTIONS – SUMMARY · solutions – summary photovoltaic inverter & storage. fimer technology park fimer factory. metal works dpt. headquarter automatic

FIMER TECHNOLOGY PARKFIMER FACTORY.

METAl WORKS DPT.

HEADQUARTER

AUTOMATIC WAREHOUSE

STATIONS METAL WORKS

Page 3: PHOTOvOlTAIC InvERTER & STORAGE SOLUTIONS – SUMMARY · solutions – summary photovoltaic inverter & storage. fimer technology park fimer factory. metal works dpt. headquarter automatic

> COMPAnY vIDEO

ElECTROnInC PCB DPT.

1 MW - ROOF Pv PlAnT

GEOTHERMIC PlAnT

STATIONS ASSEMBLY

Established in 1942, FIMER is a Company unique in the world.Indeed, we have a completely new integrated system of internal organization and Operations.

FIMER integrates all the steps of a Plant realization. Starting from design to production of semifinished products, such as electronic boards and wiring carpentry, up to the production of finished products, such as Inverters, QPPI and combiner box, and to the realization of the complete Stations.

All over the world there are no other industrial Companies able to do that. Able to integrate in the best way every activity with the purpose of better controlling the whole production process and, above all, assuring the maximum flexibility to the Customer.

In Europe, FIMER has the only Laboratory for Tests able to simulate any condition of the network at a global level. Thanks to this plus we can always be ready to reply to any condition of the market and be Compliant before the competition.

FIMER is a wide Global Company, with branches in 72 Countries in the world. In particular, with Solar Division we realized Utility or large Scale plants in the main markets in the world, such as Europe, Middle East, Africa and latin America.Thanks to our Branches in Romania, Algeria, USA, Chile and Brazil, we can support our Customers in every step of the project, from engineering to production, from general activities to commissioning and O&M.The plant construction is only the 50% of our work. We are really satisfied when the efficiency is granted for a long time, when support is at the highest level and when we can quickly step in, thanks to our local presence.

> ZERO EMISSION > 36.000 SQUARE METERS OF COvEREd > 120.000 SQUARE METERS SURFACE > 3.200 SQUARE METERS OFFICES

Page 4: PHOTOvOlTAIC InvERTER & STORAGE SOLUTIONS – SUMMARY · solutions – summary photovoltaic inverter & storage. fimer technology park fimer factory. metal works dpt. headquarter automatic

www.fi mer.com

PRODUCTS RAnGE

Mv CEnTRAl InvERTERS @1.000 v

nOMInAl AC vOlTAGE 270 vAC

R1500TlI R2250TlI R2500TlI R3000TlI R3750TlI R4500TlI R5000TlI R6000Tl R6800Tl R7500TlMPPT vOLTAGE RANGE *(Note 1) vdC 485 - 820

MAXIMUM dC vOLTAGE vdC 1.000

MAXIMUM INPUT CURRENT AdC 300 450 500 600 750 900 1.050 1.200 1.350 1.500

MAX APPARENT POWER *(Note 1) kvA 138 207 228 276 345 414 483 552 621 690

MAX AC CURRENT AAC 300 445 490 592 740 890 1.035 1.185 1.330 1.480

NR PhASE 3 + PE

FREQUENCY hz 50/60

dISTORTION FACTOR *(Note 2) Thdi <3%

POWER FACTOR *(Note 3) From 0 to 1

GALvANIC INSULATION No (transformerless)

MAXIMUM EFFICIENCY % 98,20 98,70 98,80 98,90

EUROPEAN EFFICIENCY % 97,80 98,20 98,30 98,62

WEIGhT kg 600 630 660 1.250 1.320 1.390 1.430 1.580 1.610 1.670

PROTECTION dEGREE IP20 (Opt.31)

dIMENSIONS (dxWxh) mm 1.400x825x2.235 1.996x825x2.235

OPERATING TEMPERATURE *(Note 5) °C -10° C +53° C

hUMIdITY NOT CONdENSING % 0÷95

hEIGhT ABOvE ThE SEA (NO dERATING) *(Note 4) m 1.500

nOMInAl AC vOlTAGE 330 vAC 400 vAC

R7200Tl R8100Tl R9000Tl R5010Tl R10000TlMPPT vOLTAGE RANGE *(Note 1) vdC 610 - 920 675 - 1.000

MAXIMUM dC vOLTAGE vdC 1.000 1.100

MAXIMUM INPUT CURRENT AdC 1.600 1.250 1.600

MAX APPARENT POWER *(Note 1) kvA 684 kvA @ 25°C667 kvA @ 50°C

770 kvA @ 25°C750 kvA @ 50°C

855 kvA @ 25°C833 kvA @ 50°C 512 1.000

MAX AC CURRENT AAC1.240 A @ 25°C1.170 A @ 50°C

1.395 A @ 25°C1.315 A @ 50°C

1.550 A @ 25°C 1.460 A @ 50°C 740 1.575

NR PhASE 3 + PE 3 + PE

FREQUENCY hz 50/60 50/60

dISTORTION FACTOR *(Note 2) Thdi <3% <3%

POWER FACTOR *(Note 3) From 0 to 1 From 0 to 1

GALvANIC INSULATION No (transformerless) No (transformerless)

MAXIMUM EFFICIENCY % 98,90 98,90

EUROPEAN EFFICIENCY % 98,62 98,20 98,62

WEIGhT kg 1.410 1.540 1.600 1.300 1.670

PROTECTION dEGREE IP20 (Opt.31) IP20 (Opt.31)

dIMENSIONS (dxWxh) mm 1.750x825x2.235 1.400x825x2.235 1.750x825x2.235

OPERATING TEMPERATURE *(Note 5) °C -10° C +53° C -10° C +53° C

hUMIdITY NOT CONdENSING % 0 ÷ 95 0 ÷ 95

hEIGhT ABOvE ThE SEA (NO dERATING) *(Note 4) m 1.500 1.500

FIMER TL series CENTRALIZEd MOdULAR INvERTERS have been specifi cally designed for the employment of large-scale photovoltaic power plants and Mv connection to the grid applications. These modular architectural and characteristics ensure extremely high yields, approximately 99% of maxium effi ciency. Thanks to modularity the confi guration of these machines is extremely fl exible and they ensure production continuity, eliminating machine downtime.Central inverters are also provided with a complete series of accessories able to optimize the operation and ensure a high standard of safety of the equipment and the plant in which they are installed.

138 UP TO 1.000 kvA

Mv CEnTRAl InvERTERS

note 1: Power factor (cosϕ)= 1 and vac nominal.note 2: Thdi is lower than 3% for inverter power

greater than 25%.note 3: P-Q capability is semicircular with radius

equal to Smax for all MPPT range. note 4: From 45°C to 53°C derating of power.note 5: Above 1.500m a.s.l. derating of the power of

1% per 100m.

note: Each inverter must be connected separately to its own Lv/Mv transformer or it has to be connected to a separate Lv secondary input of the Lv/Mv transformer. Two or more inverters cannot be connected in parallel to the same Lv secondary input of the Lv/Mv transformer.

Page 5: PHOTOvOlTAIC InvERTER & STORAGE SOLUTIONS – SUMMARY · solutions – summary photovoltaic inverter & storage. fimer technology park fimer factory. metal works dpt. headquarter automatic

SOLUTIONSMAX POWER @1.000v

COMBInER BOXES @1.000 vSTRInG MOnITORInG

SBC 0810 SBC 1210 SBC 1610 SBC 2010 SBC 2410MAX vOLTAGE *(Note 1) vdC 1.000INPUT CABLE ENTRY Cable glandCONdUCTOR CROSS SECTION mmq 4 - 6N° FUSE Nr. 16 24 32 40 48FUSE TYPE /SIZE (*) AdC 10,3 x 38 - gPv Type / up to 30OUTPUT CABLE GLANd (*) 2xPG29 4xPG29CURRENT OUTPUT dC SWITCh (dC-21B) A 160 250hOUSING GRP (Glass fi ber reinforced polyester)dIMENSIONS (dxWxh) mm 423x265x685 550x270x700WEIGhT kg 17,6 19,5 23 24,5 25,5EXTERNAL PROTECTION dEGREE IP65OPERATING TEMPERATURE / hUMIdITY -20 ... +50° C / 0÷95%hEIGhT ABOvE ThE SEA *(Note 1) m 1.500

ELECTRONIC EQUIPMENT ONBOARd- Monitor single string current- Monitor vdC

- Monitor SPd status- Monitor internal temperature

ELECTRONIC EQUIPMENT FOR PROBE MONITOR

- Analog input 0-5v/4-20 mA- Analog input 0-10 v- RTd PT100 4 wire- digital input dry contact

COMMUNICATION PROTOCOL MOdBUS RTUCURRENT REAdING TIPOLOGY /ACCURACY hall effect / 0.5% f.s.

COMBInER BOXES @1.000 vZOnE MOnITORInG

SB 1010 SB 1210 SB 1610 SB 2410 SB 3210MAX vOLTAGE *(Note 1) vdC 1.000INPUT CABLE ENTRY Cable glandCONdUCTOR CROSS SECTION mmq 4 - 6N° FUSE Nr. 20 24 32 48 64FUSE TYPE /SIZE (*) AdC 10,3 x 38 - gPv / 10 A to 25 A 10,3 x 38 - gPv / 10 A to 20 A

OUTPUT CABLE GLANd (*) Nr. 1 M50x1.5 (with reduction) per pole

Nr. 2 M50x1.5 (with reduction) per pole

CURRENT OUTPUT dC SWITCh (dC-21B) A 160 250 400hOUSING GRP (Glass Fiber Reinforced Polyester)dIMENSIONS (dxWxh) mm 550x270x650 618x325x822WEIGhT kg 16 18 22 26 36EXTERNAL PROTECTION dEGREE IP65OPERATING TEMPERATURE / hUMIdITY -20 ... +50° C / 0÷95%hEIGhT ABOvE ThE SEA *(Note 1) m 1.500

8 UP TO 32 Pv StringThe FIMER Combiner boxes, SB series, are high-performance panel available to ensure the fi rst parallel connection of the Pv modules of the solar generator modules and able to allow protection of solar panels from overcurrent through the use of appropriate fuses. The robust exterior box and the small sizes of the string boxes guarantee that the combiner boxes can be installed outdoors in a quick and safe way.

The FIMER Combiner boxes, SBC series, are intelligent control boxes (SMART) which allow the measurement of the current of each input Pv string from the solar generator and allow the creation of the parallel output of all the strings of Pv modules connected to them. These high-performance devices implement the current measurement and ensure an accurate localization of the malfunction of the Pv fi eld minimizing the production downtime and facilitating the timely and targeted intervention of Service.

COMBInER BOXES

STORAGE InvERTERS @1.000 v

nOMInAl AC vOlTAGE 270 vAC 330 vAC

S3750Tl S7500Tl S4500Tl S9000Tl

BATTERY vOLTAGE RANGE vdC 485 – 1.000 485 – 1.000 610 – 1.000 610 – 1.000

MAXIMUM dC vOLTAGE vdC 1.100

BATTERY TYPE Li-ion, Lead, Ni-Cd, NaNiCl2

MAXIMUM dC CURRENT AdC 800 1.600 800 1.600

MAX APPARENT POWER kvA 345 690 416 833

MAX AC CURRENT AAC 740 1.480 730 1.460

FREQUENCY hz 50 / 60dISTORTION FACTOR *(Note 1) Thdi <3%

POWER FACTOR *(Note 2) From 0 to 1

GALvANIC INSULATION NO (transformerless)

MAX EFFICIENCY % 98,9

EUROPEAN EFFICIENCY % 98,6

WEIGhT kg 1.100 1.600 1.100 1.600

dIMENSIONS (hxLxP) mm 2.250 x 1.400 x 825

2.250 x 2.000 x 825

2.250 x 1.400 x 825

2.250 x 2.000 x 825

PROTECTION dEGREE IP20 (Opt. IP31)

hUMIdITY NOT CONdENSING % 0÷95hEIGhT ABOvE ThE SEA WIThOUT dERATING *(Note 3) m 1.500

345 UP TO 833 kvAFIMER transformerless Mv CENTRALIZEd STORAGE INvERTER is a bidirectional three phase inverter specifi cally designed for implement storage solution in large-scale Pv plant and Mv connected installation.They are completely compatible with all different types of battery and storage technology and the most important benefi ts and applications are: Load & Time shifting, Ramp control, Frequency regulation, Power quality, Active power management and Reactive grid compensation

Mv CEnTRAl STORAGE InvERTERS

note 1: Thdi is lower than 3% for inverter power greater than 25%.note 2: P-Q capability is circular.note 3: Above 1.500 m derate the Maximum Operating Temperature of 0.4 °C per 100 m up to 3.000 m a.s.l.

note: Each inverter must be connected separately to its own Lv/Mv transformer or it has to be connected to a separate Lv secondary input of the Lv/Mv transformer. Two or more inverters cannot be connected in parallel to the same Lv secondary input of the Lv/Mv transformer.

note 1 derating of vN versus altitude. 1,0 % per 100 m from 2.001 m to 3.000 m. 1,2 % per 100 m from 3.001 m to 4.000 m.

(*) Contact factory for different value

Page 6: PHOTOvOlTAIC InvERTER & STORAGE SOLUTIONS – SUMMARY · solutions – summary photovoltaic inverter & storage. fimer technology park fimer factory. metal works dpt. headquarter automatic

www.fi mer.com

PRODUCTS RAnGE

SOLUTIONSMAX POWER @1.000v

MS MEGASTATIOnS @1.000 v

MS 1000 MS 1500 MS 2000 MS 2500 MS 3000 MS 4000MAX vOLTAGE dC SIdE v 1.000MAX INPUT dC SIdE Nr. 14 21 28APPARENT POWER AC SIdE kvA 1.000 1.500 2.000 2.500 3.000 4.000MAX vOLTAGE AC SIdE kv 40.5 40.5 40.5 40.5 40.5 40.5Mv SWITChGEAR Nr. 1 1 1 1 1 1POWER TRANSFORMER:

1.000 KvA INdOOR Nr. 1 - - - - -1.500 KvA INdOOR Nr. - 1 - - - -2.000 KvA INdOOR Nr. - - 1 - - -2.000 KvA OUTdOOR Nr. - - - - - 22.500 KvA OUTdOOR Nr. - - - 1 - -3.000 KvA OUTdOOR Nr. - - - - 1 -

INvERTER:R6800 TL INvERTER Nr. 2 - - - - -R9000 TL INvERTER Nr. - 2 - 3 - -R10000 TL INvERTER Nr. - - 2 - 3 4

METAL CABINET INvERTER (20’ hIGh CUBE) Nr. 1 1 1 - - -METAL CABINET INvERTER (40’ hIGh CUBE) Nr. - - - 1 1 1AUXILIARY TRANSFORMER Yes Yes Yes Yes Yes YesLv BOARd Yes Yes Yes Yes Yes YesUPS Yes Yes Yes Yes Yes YesLIGhTING SYSTEM ANd SOCKETS Yes Yes Yes Yes Yes YesFIRE dETECTION SYSTEM Yes Yes Yes Yes Yes YesMONITORING BOARd Yes Yes Yes Yes Yes YesvENTILATION SYSTEM Yes Yes Yes Yes Yes YesFIXEd POWER FACTOR PANEL As option As option As option As option As option As optionhUMAN PRESENCE As option As option As option As option As option As optiondOOR dETECTION As option As option As option As option As option As optionANTI-ROdENT PROTECTION As option As option As option As option As option As optionENvIRONMENTAL SENSORS As option As option As option As option As option As optionFOUNdATION As option As option As option As option As option As option

1.000 UP TO 4.000 kvAMEGASTATION is a complete “turnkey” solution for the conversion of energy produced by large Pv installation into electricity feed into the Mv distribution grid. Thanks to the fl exibility of the different sizes of power and the ease of connection and commissioning they provide fast installation extremely quick and rapid.

The MEGASTATION are available in six power size: 1.000 - 1.500 - 2.000 - 2.500 - 3.000 - 4.000 - kvA (Max power dC @1.000v).

MEGASTATIOnSCOnvERSIOn UnITMEGASTATIOnS

1.000 UP TO 4.000 kvAMEGASTATION is a complete “turnkey” solution for the conversion of energy produced by large Pv installation into electricity feed into the Mv distribution grid. Thanks to the fl exibility of the different sizes of power and the ease of connection and commissioning they provide fast installation extremely quick and rapid.

The MEGASTATION are available in six power size: 1.000 - 1.500 - 2.000 - 2.500 - 3.000 - 4.000 - kvA (Max power dC @1.000v).

COnvERSIOn UnIT

1.000 UP TO 4.000 kvAMEGASTATION is a complete “turnkey” solution for the conversion of energy produced by large Pv installation into electricity feed into the Mv distribution grid. Thanks to the fl exibility of the different sizes of power and the ease of connection and commissioning they provide fast installation extremely quick and rapid.

The MEGASTATION are available in six power size: 1.000 - 1.500 - 2.000 - 2.500 - 3.000 - 4.000 - kvA (Max power dC @1.000v).

COnvERSIOn UnIT

different confi guration are available on request

Page 7: PHOTOvOlTAIC InvERTER & STORAGE SOLUTIONS – SUMMARY · solutions – summary photovoltaic inverter & storage. fimer technology park fimer factory. metal works dpt. headquarter automatic

SOLUTIONSMAX POWER @1.500v

Mv CEnTRAl InvERTERS @1.500 v

nOMInAl AC vOlTAGE 400 vAC 550 vAC

R5515Tl R6615Tl R7715Tl R8815Tl R10015Tl R11015Tl R12715Tl R14015Tl R15315TlMPPT vOLTAGE RANGE *(Note 1) vdC 675 - 1.320 850 - 1.320

MAXIMUM INPUT CURRENT AdC 800 960 1.120 1.280 1.440 1.600 1.600 2.000 2.000

MAX APPARENT POWER *(Note 1) kvA 513 615 718 820 923 1.025 1.198 kvA@25°C1.128 kvA@50°C

1.348 kvA@25°C1.270 kvA@50°C

1.498 kvA@25°C1.410 kvA@50°C

MAX AC CURRENT AAC 741 889 1.037 1.185 1.333 A 1.480 1.260 A @ 25°C1.184 A @ 50°C

1.418 A @ 25°C1.332 A @ 50°C

1.575 A @ 25°C 1.480 A @ 50°C

NR PhASE 3 + PE

FREQUENCY hz 50/60

dISTORTION FACTOR *(Note 2) Thdi <3%

POWER FACTOR *(Note 3) From 0 to 1

GALvANIC INSULATION No (transformerless)

MAXIMUM EFFICIENCY % 98,80 98,90

EUROPEAN EFFICIENCY % 98,30 98,62

WEIGhT kg 1.300 1.330 1.400 1.430 1.500 1.530 1.410 1.540 1.600

PROTECTION dEGREE IP20 (Opt.31)

dIMENSIONS (dxWxh) mm 1.400x825x2.235 1.996x825x2.235

OPERATING TEMPERATURE *(Note 5) °C -10° C +53° C

hUMIdITY NOT CONdENSING % 0 ÷ 95

hEIGhT ABOvE ThE SEA (NO dERATING) *(Note 4) m 1.500

FIMER TL series CENTRALIZEd MOdULAR INvERTERS have been specifi cally designed for the employment of large-scale photovoltaic power plants and Mv connection to the grid applications. These modular architectural and characteristics ensure extremely high yields, approximately 99% of maxium effi ciency. Thanks to modularity the confi guration of these machines is extremely fl exible and they ensure production continuity, eliminating machine downtime.Central inverters are also provided with a complete series of accessories able to optimize the operation and ensure a high standard of safety of the equipment and the plant in which they are installed.

513 UP TO 1.685 kvA

Mv CEnTRAl InvERTERS

nOMInAl AC vOlTAGE 620 vAC 460 vAC (**)

R15615Tl R16615Tl R18615Tl R13015TlMPPT vOLTAGE RANGE *(Note 1) vdC 980 - 1.320 850 - 1.320

MAXIMUM INPUT CURRENT AdC 3.000 3.000 3.000 2.000

MAX APPARENT POWER *(Note 1) kvA 1.347 kvA @ 25°C1.270 kvA @ 50°C

1.516 kvA @ 25°C1.429 kvA @ 50°C

1.685 kvA @ 25°C1.588 kvA @ 50°C

1.250 kvA @ 25°C1.175 kvA @ 50°C

MAX AC CURRENT AAC1.260 A @ 25°C1.184 A @ 50°C

1.418 A @ 25°C1.332 A @ 50°C

1.575 A @ 25°C 1.480 A @ 50°C

1.575 A @ 25°C1.480 A @ 50°C

NR PhASE 3 + PE 3 + PE

FREQUENCY hz 50/60 50/60

dISTORTION FACTOR *(Note 2) Thdi <3% <3%

POWER FACTOR *(Note 3) From 0 to 1 From 0 to 1

GALvANIC INSULATION No (transformerless) No (transformerless)

MAXIMUM EFFICIENCY % 98.90 98.90

EUROPEAN EFFICIENCY % 98.62 98.62

WEIGhT kg 1.410 1.540 1.600 1.600

PROTECTION dEGREE IP20 (Opt.31) IP20 (Opt.31)

dIMENSIONS (dxWxh) mm 1.996x825x2.235 1.996x825x2.235

OPERATING TEMPERATURE *(Note 5) °C -10° C +53° C -10° C +53° C

hUMIdITY NOT CONdENSING % 0 ÷ 95 0 ÷ 95

hEIGhT ABOvE ThE SEA (NO dERATING) *(Note 4) m 1.500 1.500

note 1: Power factor (cosϕ)= 1 and vac nominal.note 2: Thdi is lower than 3% for inverter power greater than 25%.note 3: P-Q capability is semicircular with radius equal to Smax for all MPPT

range. note 4: From 45°C to 53°C derating of power.note 5: Above 1.500m a.s.l. derating of the power of 1% per 100m. note: Each inverter must be connected separately to its own Lv/Mv

transformer or it has to be connected to a separate Lv secondary input of the Lv/Mv transformer. Two or more inverters cannot be connected in parallel to the same Lv secondary input of the Lv/Mv transformer.

(**) AC output voltage 460vRMS -10% / +30%

Page 8: PHOTOvOlTAIC InvERTER & STORAGE SOLUTIONS – SUMMARY · solutions – summary photovoltaic inverter & storage. fimer technology park fimer factory. metal works dpt. headquarter automatic

www.fi mer.com

PRODUCTS RAnGE

80 UP TO 120 kvA

The new 3Ph string inverters have been specifi cally designed mainly for commercial and large scale distributed Pv Plants both indoor and outdoor (IP 65). Thanks to fl exible installation and to wide Thanks to fl exible installation and to wide operating voltage range (850-1.320 vdC) the new inverters are easily confi gured with any type of panel and installation. The accurate and rapid MPPT algorithm ensures high levels of performance and a signifi cant producibility of energy thanks to a constant and stable performance across the entire operating range.

80 UP TO 120 kvA

The new 3Ph string inverters have been specifi cally designed mainly for commercial and large scale distributed Pv Plants both indoor and outdoor (IP 65). Thanks to fl exible installation and to wide Thanks to fl exible installation and to wide operating voltage range (850-1.320 vdC) the new inverters are easily confi gured with any type of panel and installation. The

3PH STRInG InvERTERS

STORAGE InvERTERS @1.500 v

nOMInAl AC vOlTAGE 400 vAC 550 vAC

S5515Tl S11015Tl S7515Tl S15015Tl

BATTERY vOLTAGE RANGE vdC 675 - 1.250 850 - 1.250

MAXIMUM dC vOLTAGE vdC 1.500

BATTERY TYPE Li-ion, Lead, Ni-Cd, NaNiCl2

MAXIMUM dC CURRENT AdC 1.250 1.600 1.250 1.600

MAX APPARENT POWER kvA 512 1.025 705 1.410

MAX AC CURRENT AAC 740 1.480 740 1.480

FREQUENCY hz 50 / 60dISTORTION FACTOR *(Note 1) Thdi <3%

POWER FACTOR *(Note 2) From 0 to 1

GALvANIC INSULATION NO (transformerless)

MAX EFFICIENCY % 98,9

EUROPEAN EFFICIENCY % 98,6

WEIGhT kg 1.100 1.600 1.100 1.600

dIMENSIONS (hxLxP) mm 2.250 x 1.400 x 825

2.250 x 2.000 x 825

2.250 x 1.400 x 825

2.250 x 2.000 x 825

PROTECTION dEGREE IP20 (OPT. IP31)

hUMIdITY NOT CONdENSING % 0 ÷ 95hEIGhT ABOvE ThE SEA WIThOUT dERATING *(Note 3) m 1.500

512 UP TO 1.025 kvA

FIMER transformerless Mv CENTRALIZEd STORAGE INvERTER is a bidirectional three phase inverter specifi cally designed for implement storage solution in large-scale Pv plant and Mv connected installation.They are completely compatible with all different types of battery and storage technology and the most important benefi ts and applications are: Load & Time shifting, Ramp control, Frequency regulation, Power quality, Active power management and Reactive grid compensation

512 UP TO 1.025 kvA

FIMER transformerless Mv CENTRALIZEd STORAGE INvERTER is a bidirectional three phase inverter specifi cally designed for implement storage solution in large-scale Pv plant and Mv phase inverter specifi cally designed for implement storage solution in large-scale Pv plant and Mv phase inverter specifi cally designed for implement

connected installation.storage solution in large-scale Pv plant and Mv connected installation.storage solution in large-scale Pv plant and Mv

They are completely compatible with all different types of battery and storage technology and the They are completely compatible with all different types of battery and storage technology and the They are completely compatible with all different

most important benefi ts and applications are: types of battery and storage technology and the most important benefi ts and applications are: types of battery and storage technology and the

Load & Time shifting, Ramp control, Frequency most important benefi ts and applications are: Load & Time shifting, Ramp control, Frequency most important benefi ts and applications are:

regulation, Power quality, Active power Load & Time shifting, Ramp control, Frequency regulation, Power quality, Active power Load & Time shifting, Ramp control, Frequency

management and Reactive grid compensationregulation, Power quality, Active power management and Reactive grid compensationregulation, Power quality, Active power

note 1: Thdi is lower than 3% for inverter power greater than 25%.note 2: P-Q capability is circular.note 3: Above 1.500 m derate the Maximum Operating Temperature of 0.4 °C per 100 m up to 3.000 m a.s.l.

note: Each inverter must be connected separately to its own Lv/Mv transformer or it has to be connected to a separate Lv secondary input of the Lv/Mv transformer. Two or more inverters cannot be connected in parallel to the same Lv secondary input of the Lv/Mv transformer.

Mv CEnTRAl STORAGE InvERTERS

3PH STRInG InvERTERS @1.500 v

nOMInAl AC vOlTAGE 550 vAC

R1015Tl R1415Tl

MPPT vOLTAGE RANGE *(Note 1) vdC 850 - 1.320

MAXIMUM dC vOLTAGE vdC 1.500

MAXIMUM INPUT CURRENT AdC 125 140

MAX APPARENT POWER *(Note 1) kvA 80 kvA @ 25°C70 kvA @ 50°C

120 kvA @ 25°C110kvA @ 50°C

MAX AC CURRENT AAC85 A @ 25°C75 A @ 50°C

128 A @ 25°C115 A @ 50°C

NR PhASE 3 + PE

FREQUENCY hz 50/60

dISTORTION FACTOR *(Note 2) Thdi <3%

POWER FACTOR *(Note 3) From 0 to 1

GALvANIC INSULATION No (transformerless)

MAXIMUM EFFICIENCY % 99,00

EUROPEAN EFFICIENCY % 98,60

WEIGhT kg 67,8 71,3

PROTECTION dEGREE IP65

dIMENSIONS (dxWxh) mm 880x640x380

OPERATING TEMPERATURE *(Note 5) °C -10° C +53° C

hUMIdITY NOT CONdENSING % 0 ÷ 95

hEIGhT ABOvE ThE SEA (NO dERATING) *(Note 4) m 1.500

note 1: valid at P.F.=1and vac nominalnote 2: Thdi is lower than 3% for inverter power greater than 25%.note 3: P-Q capability is semicircular.note 4: Above 1800m derate the Maximum Operating Temperature of 0.4 °C per 100 m up to3000 m a.s.l. above 2000m derate the Absolute Maximum dC voltage of 1.3 % per 100 m up to3000 m a.s.l. above 2000m derate the Maximum MPPT voltage of 1.2 % per 100 m up to3000 m a.s.l. (contact Factory for details).

Page 9: PHOTOvOlTAIC InvERTER & STORAGE SOLUTIONS – SUMMARY · solutions – summary photovoltaic inverter & storage. fimer technology park fimer factory. metal works dpt. headquarter automatic

SOLUTIONSMAX POWER @1.500v

COMBInER BOXES @1.500 vSTRInG MOnITORInG

FUSE SIZE UP TO 20 A UP TO 50 A

SBC 0815 SBC 1215 SBC 1615 SBC 2015 SBC 2415 SBC 0815-50MAX vOLTAGE *(Note 1) vdC 1.500 1.500INPUT CABLE ENTRY Cable gland Cable glandCONdUCTOR CROSS SECTION mmq 4 - 6 10N° FUSE Nr. 16 24 32 40 48 8FUSE TYPE /SIZE AdC 10x85 - gPv Type curve / up 20 A 22x65 - gPv Type curve / up 50 AOUTPUT CABLE GLANd 2xPG29 2xPG36 4xPG36 Nr. 1 M50x1,5 (with reduction) per poleCURRENT OUTPUT dC SWITCh (dC-21B) A 160 250 300 AhOUSING GRP (Glass fi ber reinforced polyester) GRP (Glass fi ber reinforced polyester)dIMENSIONS (dxWxh) mm 550x270x700 670x325x862 550x270x650WEIGhT kg 18,7 20,4 24,1 25,7 26,8 24EXTERNAL PROTECTION dEGREE IP65 IP65OPERATING TEMPERATURE / hUMIdITY -20 ... +50° C / 0÷95% -20 ... +50° C / 0÷95%hEIGhT ABOvE ThE SEA *(Note 1) m 1.500 1.500

ELECTRONIC EQUIPMENT ON BOARd- Monitor single string current- Monitor vdC

- Monitor SPd status- Monitor internal temperature

- Monitor single input current- Monitor vdC

- Monitor SPd status- Monitor internal temperature

ELECTRONIC EQUIPMENT FOR PROBE MONITOR

- Analog input 0-5v/4-20 mA- Analog input 0-10 v- RTd PT100 4 wire- digital input dry contact

- Analog input 0-5v/4-20 mA- RTd PT100 4 wire- digital input dry contact

COMMUNICATION PROTOCOL MOdBUS RTU MOdBUS RTUCURRENT REAdING TIPOLOGY /ACCURACY hall effect / 0.5% f.s. hall effect / 0.5% f.s.

COMBInER BOXES @1.500 vZOnE MOnITORInG

FUSE SIZE UP TO 20 A UP TO 50 A

SB 1615 SB 2015 SB 2415 SB 3215 SB 0815-50 SB 0915-50 SB 1015-50MAX vOLTAGE *(Note 1) vdC 1.500 1.500INPUT CABLE ENTRY Cable gland Cable glandCONdUCTOR CROSS SECTION mmq 4 - 6 10N° FUSE Nr. 20 32 48 64 8 9 10FUSE TYPE (*) AdC 10x85 - gPv Type curve 22x65 - gPv Type curve

OUTPUT CABLE GLANd (*) Nr. 1 PG per pole Nr. 1 PG per pole

CURRENT OUTPUT dC SWITCh (dC-21B) A 250 400 300hOUSING GRP (Glass Fiber Reinforced Polyester) GRP (Glass Fiber Reinforced Polyester)dIMENSIONS (dxWxh) mm 550x270x650 618x325x822 550 x 270 x 650WEIGhT kg 22 24 26 36 24 25 25EXTERNAL PROTECTION dEGREE IP65 IP65OPERATING TEMPERATURE / hUMIdITY -20 ... +50° C / 0÷95% -20 ... +50° C / 0÷95%hEIGhT ABOvE ThE SEA *(Note 1) m 1.500 1.500

8 UP TO 32 Pv String

COMBInER BOXES

note 1 derating of vN versus altitude. 1,0 % per 100 m from 2.001 m to 3.000 m. 1,2 % per 100 m from 3.001 m to 4.000 m.

(*) Contact factory for different value

The FIMER Combiner boxes, SB series, are high-performance panel available to ensure the fi rst parallel connection of the Pv modules of the solar generator modules and able to allow protection of solar panels from overcurrent through the use of appropriate fuses. The robust exterior box and the small sizes of the string boxes guarantee that the combiner boxes can be installed outdoors in a quick and safe way.

The FIMER Combiner boxes, SBC series, are intelligent control boxes (SMART) which allow the measurement of the current of each input Pv string from the solar generator and allow the creation of the parallel output of all the strings of Pv modules connected to them. These high-performance devices implement the current measurement using hall effect transducers and ensure an accurate localization of the malfunction of the Pv fi eld minimizing the production downtime and facilitating the timely and targeted intervention of Service.

Page 10: PHOTOvOlTAIC InvERTER & STORAGE SOLUTIONS – SUMMARY · solutions – summary photovoltaic inverter & storage. fimer technology park fimer factory. metal works dpt. headquarter automatic

www.fi mer.com

PRODUCTS RAnGE

SOLUTIONSMAX POWER @1.500v

2.050 UP TO 6.150 kvA

MEGASTATION is a complete “turnkey” solution for the conversion of energy produced by large Pv installation into electricity feed into the Mv distribution grid. Thanks to the fl exibility of the different sizes of power and the ease of connection and commissioning they provide fast installation extremely quick and rapid.

The MEGASTATION are available in six power size: 2.050 - 3.075 - 4.100 - 5.000 - 5.640 -6.150 kvA (Max power dC @1.500v).

2.050 UP TO 6.150 kvA

MEGASTATION is a complete “turnkey” solution for the conversion of energy produced by large Pv installation into electricity feed into the Mv distribution grid. Thanks to the fl exibility of the different sizes of power and the ease of connection and commissioning they provide fast installation extremely quick and rapid.

The MEGASTATION are available in six power size: 2.050 - 3.075 - 4.100 - 5.000 - 5.640 -6.150 kvA (Max power dC @1.500v).

2.050 UP TO 6.150 kvA

MEGASTATION is a complete “turnkey” solution for the conversion of energy produced by large Pv installation into electricity feed into the Mv distribution grid. Thanks to the fl exibility of the different sizes of power and the ease of connection and commissioning they provide fast installation extremely quick and rapid.

The MEGASTATION are available in six power size: 2.050 - 3.075 - 4.100 - 5.000 - 5.640 -6.150 kvA (Max power dC @1.500v).

MEGASTATIOnSCOnvERSIOn UnIT

MS MEGASTATIOnS @1.500 v

MS 2200 MS 3300 MS 4400 MS 5200 MS 6000 MS 6000 FIMAX vOLTAGE dC SIdE v 1.500MAX INPUT dC SIdE Nr. 10 15 20 20 20 20APPARENT POWER AC SIdE kvA 2.050 3.075 4.100 5.000 5.640 6.150MAX vOLTAGE AC SIdE kv 40.5 40.5 40.5 40.5 40.5 40.5Mv SWITChGEAR Nr. 1 1 1 1 1 1POWER TRANSFORMER:

2.050 KvA INdOOR Nr. 1 - - - - -2.050 KvA OUTdOOR Nr. - - 2 - - -2.500 KvA OUTdOOR Nr. - - - 2 - -2.850 KvA OUTdOOR Nr. - - - - 2 -3.075 KvA OUTdOOR Nr. - 1 - - - -

INvERTER:R11015 TL INvERTER Nr. 2 3 4 - - -R13015 TL INvERTER Nr. 4 - -R15015 TL INvERTER Nr. - - - - 4 -

METAL CABINET INvERTER (20’ hIGh CUBE) Nr. 1 - - - - -METAL CABINET INvERTER (40’ hIGh CUBE) Nr. - 1 1 1 1 1Auxiliary Transformer Yes Yes Yes Yes Yes YesLv Board Yes Yes Yes Yes Yes YesUPS Yes Yes Yes Yes Yes YesLighting system and sockets Yes Yes Yes Yes Yes YesFire detection system Yes Yes Yes Yes Yes YesMonitoring Board Yes Yes Yes Yes Yes Yesventilation system Yes Yes Yes Yes Yes YesFixed power factor panel As option As option As option As option As option As optionhuman presence As option As option As option As option As option As optiondoor detection As option As option As option As option As option As optionAnti-rodent protection As option As option As option As option As option As optionEnvironmental Sensors As option As option As option As option As option As optionFoundation As option As option As option As option As option As option

different confi guration are available on request

Page 11: PHOTOvOlTAIC InvERTER & STORAGE SOLUTIONS – SUMMARY · solutions – summary photovoltaic inverter & storage. fimer technology park fimer factory. metal works dpt. headquarter automatic

SOME REFEREnCES. > ChILE > 160 MW

> GREECE > 8.9 MW

> BRASILE > 11 MW

> ChILE > 100 MW

Page 12: PHOTOvOlTAIC InvERTER & STORAGE SOLUTIONS – SUMMARY · solutions – summary photovoltaic inverter & storage. fimer technology park fimer factory. metal works dpt. headquarter automatic

FIMER S.p.A.via J.F. Kennedy - 20871 vimercate (MB)ItalyPhone +39 039 98981Fax +39 039 6079334

[email protected]@fimer.com

910.

200.

247G

B RE

v00

2003

.201

7 > COMPAnY vIDEO