photometric test report...0.0006 power factor 0.995 test results luminous efficacy (lm/w) 4.1...

16
Prepared By Approved By Photometric Test Report Relevant Standards The results contained in this report pertain only to the tested sample. This report shall not be reproduced, except in full, without written approval of Underwriters Laboratories. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. Alvin Xie Imo Fan, Dendi Lin Prepared For Builders Pack No.701, BuildingA, Shenfubao Industry Park, Futina District, Shenzhen PRC 518017 Test Laboratory: UL Verification Services (Guangzhou) Co., Ltd. Test Laboratory Address: Building A1, 1F & 2F, Nansha Science and Technology Innovation Center, No. 25, South Huanshi Avenue, Nansha District, Guangzhou 511458, China Catalog Number 33-LHB-14-7320-8XX-D-[S;N]-LP Project Number 4788294525 Report Number 4788294525-2aR01 Test Date 3/29/2018 - 4/4/2018 Issue Date 4/4/2018 Revision Date 4/18/2018 IES LM-79-2008 ANSI C82.77-10-2014 UL1598-2008 Doc No: 10-AHL-F0008 Issue: 1.3 UL Report Number 4788294525-2aR01 Page 1 of 16

Upload: others

Post on 01-Dec-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Photometric Test Report...0.0006 Power Factor 0.995 Test Results Luminous Efficacy (lm/W) 4.1 Integrating Sphere Test for the lower CCT 1.The sample was tested according to the IES

Prepared By Approved By

Photometric Test Report

Relevant Standards

The results contained in this report pertain only to the tested sample.

This report shall not be reproduced, except in full, without written approval of Underwriters Laboratories.

This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S.

Government.

Alvin XieImo Fan, Dendi Lin

Prepared For

Builders PackNo.701, BuildingA, Shenfubao Industry Park, Futina District, Shenzhen PRC 518017

Test Laboratory: UL Verification Services (Guangzhou) Co., Ltd.

Test Laboratory Address: Building A1, 1F & 2F, Nansha Science and Technology Innovation

Center, No. 25, South Huanshi Avenue, Nansha District, Guangzhou 511458, China

Catalog Number

33-LHB-14-7320-8XX-D-[S;N]-LP

Project Number

4788294525

Report Number

4788294525-2aR01

Test Date

3/29/2018 - 4/4/2018

Issue Date

4/4/2018

Revision Date

4/18/2018

IES LM-79-2008

ANSI C82.77-10-2014

UL1598-2008

Doc No: 10-AHL-F0008

Issue: 1.3

UL Report Number 4788294525-2aR01 Page 1 of 16

Page 2: Photometric Test Report...0.0006 Power Factor 0.995 Test Results Luminous Efficacy (lm/W) 4.1 Integrating Sphere Test for the lower CCT 1.The sample was tested according to the IES

1.0 Test Summary

Requirement Category Test Method Requirements Test valueResults

(Fail/Pass)Minimum Light Output (lm) IES LM-79-2008 ≥10000 40,481.52 Pass

Minimum Bare Lamp Output (lm) IES LM-79-2008 N/A N/A N/A

Spacing Criteria (0-180°) IES LM-79-2008 N/A N/A N/A

Spacing Criteria (90-270°) IES LM-79-2008 N/A N/A N/A

Zonal Lumen Requirement (20°-50°) IES LM-79-2008 ≥30% 50.30% Pass

Zonal Lumen Requirement 2 IES LM-79-2008 N/A N/A N/A

Minimum Luminaire Efficacy (lm/W) IES LM-79-2008 ≥126.1 128.69 Pass

Minimum Lamp Efficacy (lm/ft) IES LM-79-2008 N/A N/A N/A

Allowable CCTs (K)IES LM-79-2008

ANSI C78.377-2015≤6022 5790 Pass

Minimum CRIIES LM-79-2008

CIE 13.3-1995≥70 74.1 Pass

L70 Lumen maintenance (hours) IES TM-21-2011* ≥50000 ≥60000 Pass

L90 Lumen maintenance (hours) IES TM-21-2011* >36000 ≥50000 Pass

Power Factor ANSI C82.77-10-2014 ≥0.9 0.9328 Pass

Total Harmonic Distortion (A%) ANSI C82.77-10-2014 ≤20% 11.76% Pass

In-Situ Temperature Measurement Test for LED (°C) UL1598-2008 ≤105 69.6 Pass

In-Situ Temperature Measurement Test for Driver (°C) UL1598-2008 ≤90 77.2 Pass

Minimum Luminaire Warranty (years) N/A 5 5 Pass

* The standards are NOT covered by the NVLAP scope of test laboratory UL Verification Services (Guangzhou) Co., Ltd.

DLC Technical Requirements v4.3- issued 2018-03-26

Doc No: 10-AHL-F0008

Issue: 1.3

UL Report Number 4788294525-2aR01 Page 2 of 16

Page 3: Photometric Test Report...0.0006 Power Factor 0.995 Test Results Luminous Efficacy (lm/W) 4.1 Integrating Sphere Test for the lower CCT 1.The sample was tested according to the IES

2.0 Test List

Test Item Test Date Model NumberTests

Conducted By

Remark (if any)

5 In-Situ Temperature Measurement Test 4/4/2018 33-LHB-14-7320-840-D-[S,N]-LP Howie Wang

33-LHB-14-7320-840-D-[S,N]-LP Vince Lin

4 THD and PF Test 3/29/2018 33-LHB-14-7320-840-D-[S,N]-LP Vince Lin

Test

1. UL test equipment information is recorded on Meter Use in UL’s Aurora database.

2. Revision description: To correct LED Model Name.

1 Integrating Sphere Test for the Lower CCT 4/4/2018 33-LHB-14-7320-840-D-[S,N]-LP Vince Lin

2 4/3/2018Integrating Sphere Test for the Higher CCT 33-LHB-14-7320-840-D-[S,N]-LP Vince Lin

3 Goniophotometer Test 3/29/2018

Doc No: 10-AHL-F0008

Issue: 1.3

UL Report Number 4788294525-2aR01 Page 3 of 16

Page 4: Photometric Test Report...0.0006 Power Factor 0.995 Test Results Luminous Efficacy (lm/W) 4.1 Integrating Sphere Test for the lower CCT 1.The sample was tested according to the IES

(a) is defined as product size, (a)=12 or 14, 12 means 1x2ft, 14 means 1x4ft;(b) is defined as wattage 80W-320W, (a)=780, 7105, 7135, 7165, 7225 and 7320;XX is defined as CCT arrange 4000K-5700K, XX=840, 845, 850 and 857;The first Y is defined as dimming status, it can be D or N, D means Dimming, N means No dimming;The second Y is defined as photocontrol fuction, it can be S or N, S means sensor, N means no sensor;X is defined as voltage range, X=L and H, L means 120-277V, H means 347-480V;The last X is defined as version of product, it can be A, B, C...... Now is X.

3.0 Production DescriptionLuminaire Description: High Bay, High Bay Luminaires for Commercial and Industrial Buildings Model Number: 33-LHB-14-7320-840-D-[S,N]-LPRated Input and CCT: 120-277 Vac, 50/60Hz, 320W, 4000K

LED Package: SPMWH1228FD5WAT0SG, SPMWH1228FD5WAQ0SG

Driver Model Number: SLP 96-I2300 120-277 W D1 SFamily Model and Variation: 33-LHB-(a)-(b)-XX-Y-Y-XX.

For detailed analysis,

33 = Series Number;LHB = High Bay;

Doc No: 10-AHL-F0008

Issue: 1.3

UL Report Number 4788294525-2aR01 Page 4 of 16

Page 5: Photometric Test Report...0.0006 Power Factor 0.995 Test Results Luminous Efficacy (lm/W) 4.1 Integrating Sphere Test for the lower CCT 1.The sample was tested according to the IES

Photos of Luminaire Characteristics

Doc No: 10-AHL-F0008

Issue: 1.3

UL Report Number 4788294525-2aR01 Page 5 of 16

Page 6: Photometric Test Report...0.0006 Power Factor 0.995 Test Results Luminous Efficacy (lm/W) 4.1 Integrating Sphere Test for the lower CCT 1.The sample was tested according to the IES

4.0 LM-79 Measurement and Test Results

Model No. Sample ID.

45

Temperature

(°C)Voltage (Vac) Frequency (Hz) Current (A) Power (W)

24.9 120.04 60 2.63 314.53

CCT (K) CRI (Ra) Duv

4142 74.1 0.0006

Power Factor

0.995

Test Results

Luminous Efficacy

(lm/W)

4.1 Integrating Sphere Test for the lower CCT

1.The sample was tested according to the IES LM-79-2008.

2.Photometric paramters were measured using an integrating sphere, a spectroradiometer and software. The ambient

temperature condition inside the sphere was maintained at 25º C ± 1º C.The reference standard lamp is rated current 0.873A omni-

directional Incandescent lamp and was calibrated by NIM.

3.The sample measurements were made using a spectroradiometer connected by a fiber optic cable and detector through the

detector port of the integrating sphere. Coating reflectance of the integrating sphere was 90% to 98%.Photometric measurement

conditions was using 4π geometry.The self-absorption factor is applied in the final test result.The sample was operated at rated

voltage and was stabilized before measurement. Chromaticity coordinates, correlated color temperature and color rendering index

were calculated from the spectral radiant flux measurements taken at 5 nm intervals over the range of 380 to 780 nm.

128.70

33-LHB-14-7320-840-D-[S,N]-LP 1509809

Test Method

Luminous Flux

(lm)

40481.52

Opreate time (Min.) 50 Stabilization time (Min.)

Integrating Sphere Test Conditions

Doc No: 10-AHL-F0008

Issue: 1.3

UL Report Number 4788294525-2aR01 Page 6 of 16

Page 7: Photometric Test Report...0.0006 Power Factor 0.995 Test Results Luminous Efficacy (lm/W) 4.1 Integrating Sphere Test for the lower CCT 1.The sample was tested according to the IES

4.0 LM-79 Measurement and Test Results

Model No. Sample ID.

45

Temperature

(°C)Voltage (Vac) Frequency (Hz) Current (A) Power (W)

25 119.93 60 2.533 301.74

CCT (K) CRI (Ra) Duv

5790 76.1 0.00313

Luminous Flux

(lm)

42823.65

4.2 Integrating Sphere Test for the higher CCT33-LHB-14-7320-857-D-[S,N]-LP 1516162

Test Method

1.The sample was tested according to the IES LM-79-2008.

2.Photometric paramters were measured using an integrating sphere, a spectroradiometer and software. The ambient

temperature condition inside the sphere was maintained at 25º C ± 1º C.The reference standard lamp is rated current 0.873A omni-

directional Incandescent lamp and was calibrated by NIM.

3.The sample measurements were made using a spectroradiometer connected by a fiber optic cable and detector through the

detector port of the integrating sphere. Coating reflectance of the integrating sphere was 90% to 98%.Photometric measurement

conditions was using 4π geometry.The self-absorption factor is applied in the final test result.The sample was operated at rated

voltage and was stabilized before measurement. Chromaticity coordinates, correlated color temperature and color rendering index

were calculated from the spectral radiant flux measurements taken at 5 nm intervals over the range of 380 to 780 nm.

Opreate time (Min.) 50 Stabilization time (Min.)

141.92

Power Factor

0.993

Luminous Efficacy

(lm/W)

Integrating Sphere Test Conditions

Test Results

Doc No: 10-AHL-F0008

Issue: 1.3

UL Report Number 4788294525-2aR01 Page 7 of 16

Page 8: Photometric Test Report...0.0006 Power Factor 0.995 Test Results Luminous Efficacy (lm/W) 4.1 Integrating Sphere Test for the lower CCT 1.The sample was tested according to the IES

5.0 LM-79 Measurement and Test ResultsModel No. Sample ID.

45

Temperature

(°C)Voltage (Vac) Frequency (Hz) Current (A) Power (W) Power Factor Orientation

24.3 120 60 2.6422 315.4 0.9946 Horizontal

Horizontal Spread Vertical SpreadHorizontal

Spread

Vertical

Spread

40,589.10 50.30% 161.9 160.3 105.3 103.4 128.69

1 4

1.The sample was tested according to the IES LM-79-2008.

2.Photometric paramters were measured using a type C goniophotometer and software.

3.The ambient temperature shall be maintained at 25° C ± 1° C, measured at a point not more than 1 m from the sample and at the

same height as the sample.The reference standard lamp is rated current 3.857A omni-directional Incandescent lamp and was

calibrated by NIM.

4.The samples were operated at rated voltage and was stabilized before measurement. Luminous flux, luminaire efficacy, zonal

lumen were calculated from the software taken at 1° vertical intervals and 22.5° horizontal intervals..Photometric distance was

more than five times of the largest dimension of the test SSL product.

33-LHB-14-7320-840-D-[S,N]-LP

Test Method

1509809

Opreate time (Min.) 55 Stabilization time (Min.)

Goniophotometer Test Conditions

Test Result

Flux

(lm)

Zonal Lumen

Requirement

(20°-50°)

Field Angle

(10%)

Beam Angle

(50%)Luminous

Efficacy

(lm/W)

Doc No: 10-AHL-F0008

Issue: 1.3

UL Report Number 4788294525-2aR01 Page 8 of 16

Page 9: Photometric Test Report...0.0006 Power Factor 0.995 Test Results Luminous Efficacy (lm/W) 4.1 Integrating Sphere Test for the lower CCT 1.The sample was tested according to the IES

Light Distribution Curve

IsoCandela Plot

2

5.2 Goniophotometer Test (Cont'd)

Doc No: 10-AHL-F0008

Issue: 1.3

UL Report Number 4788294525-2aR01 Page 9 of 16

Page 10: Photometric Test Report...0.0006 Power Factor 0.995 Test Results Luminous Efficacy (lm/W) 4.1 Integrating Sphere Test for the lower CCT 1.The sample was tested according to the IES

Zonal Lumen Summary

Lumens Per Zone

3

5.2 Goniophotometer Test (Cont'd)

Doc No: 10-AHL-F0008

Issue: 1.3

UL Report Number 4788294525-2aR01 Page 10 of 16

Page 11: Photometric Test Report...0.0006 Power Factor 0.995 Test Results Luminous Efficacy (lm/W) 4.1 Integrating Sphere Test for the lower CCT 1.The sample was tested according to the IES

Intensity Data(cd)

4

5.2 Goniophotometer Test (Cont'd)

0 22.5 45 67.5 90 112.5 135 157.5 180 202.5 225 247.5 270 292.5 315 337.5 360

0 15104 15096 15046 15016 15031 15037 15095 15138 15132 15118 15077 15054 15054 15049 15102 15138 15134

1 15091 15081 15043 15013 15022 15032 15083 15121 15118 15109 15063 15037 15031 15042 15097 15137 15118

2 15097 15084 15038 15014 15014 15027 15088 15122 15119 15106 15073 15032 15021 15035 15087 15124 15118

3 15076 15067 15023 15005 15002 15014 15074 15110 15104 15094 15047 15011 15010 15016 15066 15102 15105

4 15046 15038 14999 14990 14976 14992 15049 15089 15082 15074 15027 14992 14974 14981 15041 15077 15072

5 15015 15003 14968 14961 14961 14971 15046 15061 15062 15056 15008 14970 14943 14946 15002 15040 15035

6 14982 14964 14951 14935 14934 14952 15007 15046 15033 15029 14983 14941 14914 14920 14969 15014 14996

7 14960 14929 14926 14900 14894 14916 14966 15014 15002 15003 14961 14920 14887 14885 14931 14975 14961

8 14923 14896 14887 14852 14841 14872 14922 14983 14967 14949 14921 14863 14856 14859 14897 14950 14927

9 14860 14859 14841 14802 14784 14805 14871 14933 14905 14893 14852 14810 14799 14809 14862 14901 14887

10 14784 14806 14764 14745 14728 14742 14818 14864 14834 14819 14786 14729 14738 14745 14814 14832 14834

11 14698 14729 14684 14676 14656 14681 14764 14783 14759 14740 14709 14667 14658 14667 14738 14756 14748

12 14612 14631 14604 14615 14597 14611 14705 14701 14681 14672 14637 14591 14566 14578 14648 14664 14661

13 14522 14540 14514 14546 14536 14539 14646 14614 14595 14592 14553 14518 14482 14492 14552 14561 14557

14 14437 14433 14426 14463 14471 14468 14559 14526 14512 14512 14472 14435 14395 14391 14449 14467 14452

15 14344 14327 14336 14369 14393 14400 14458 14444 14428 14432 14386 14353 14316 14301 14335 14365 14344

16 14257 14219 14235 14276 14296 14314 14360 14350 14342 14348 14306 14279 14222 14197 14232 14257 14241

17 14160 14108 14146 14174 14183 14225 14243 14262 14253 14273 14226 14200 14128 14099 14122 14157 14124

18 14064 13997 14049 14064 14076 14118 14140 14166 14154 14168 14120 14092 14036 14006 14012 14053 14015

19 13965 13881 13954 13960 13950 13990 14030 14078 14064 14040 14016 13979 13951 13900 13902 13943 13897

20 13852 13774 13849 13850 13834 13857 13918 13963 13939 13903 13888 13840 13839 13800 13785 13842 13779

25 13060 13166 13108 13162 13188 13170 13270 13211 13174 13157 13138 13114 13110 13140 13190 13162 13179

30 12212 12242 12267 12372 12394 12440 12422 12378 12364 12390 12350 12345 12268 12241 12287 12233 12250

35 11372 11264 11400 11458 11454 11498 11549 11529 11518 11507 11508 11472 11417 11319 11290 11303 11254

40 10329 10275 10433 10459 10501 10451 10540 10506 10443 10405 10411 10376 10460 10397 10294 10354 10248

45 9101 9256 9238 9386 9457 9377 9405 9306 9246 9245 9218 9232 9280 9378 9250 9312 9214

50 7864 8206 8012 8274 8331 8242 8226 8075 8022 8053 8013 8053 8066 8205 8186 8129 8149

55 6760 7025 6814 7148 7182 7110 7036 6924 6915 6889 6902 6882 6856 7009 7096 6930 7044

60 5748 5825 5722 6027 6034 5991 5869 5880 5882 5775 5856 5766 5750 5821 5914 5748 5850

65 4767 4667 4694 4883 4917 4908 4753 4881 4896 4715 4852 4711 4725 4681 4735 4610 4680

70 3639 3556 3704 3767 3829 3858 3684 3861 3820 3701 3811 3694 3735 3589 3605 3527 3564

75 2486 2523 2685 2713 2756 2782 2689 2718 2666 2751 2667 2738 2729 2572 2552 2518 2528

80 1446 1584 1610 1727 1750 1746 1778 1660 1624 1755 1614 1722 1651 1643 1594 1602 1588

85 557 756 665 809 846 823 902 740 712 801 694 756 694 801 746 778 758

90 75 132 54 76 79 96 141 119 117 129 70 42 20 66 116 126 142

95 10 11 10 12 12 11 10 11 10 10 11 11 12 11 10 10 10

100 9 9 10 11 11 10 10 10 11 10 10 10 10 10 10 10 9

105 9 10 10 10 11 11 9 9 9 9 10 11 11 10 10 10 10

110 10 11 11 11 10 10 10 10 10 10 12 11 11 12 11 10 10

115 11 12 12 12 11 12 12 12 11 10 11 12 13 12 12 12 11

120 12 13 12 13 13 12 12 12 13 12 12 13 13 12 12 12 12

125 13 13 13 14 14 13 13 14 13 13 13 14 14 14 14 13 13

130 14 15 15 15 15 14 14 14 13 14 15 14 15 16 14 14 14

135 16 16 16 16 16 16 16 15 15 15 16 16 16 17 16 16 16

140 17 17 17 18 18 18 18 17 16 17 18 17 18 18 18 18 18

145 19 18 19 18 19 18 19 19 19 18 19 19 19 19 19 19 19

150 20 19 20 20 20 19 20 20 20 20 20 20 20 20 20 20 20

155 20 20 20 20 20 20 21 20 20 20 21 21 20 21 21 20 21

160 21 22 22 22 21 21 21 22 22 21 22 22 22 22 22 22 22

165 24 26 25 25 24 24 23 25 25 24 25 24 24 23 24 24 25

170 29 31 30 28 27 26 26 27 30 31 30 27 25 25 26 28 29

175 35 34 31 29 28 28 30 33 36 34 31 28 28 28 29 33 35

180 36 36 32 30 29 30 33 34 36 34 32 30 28 30 32 34 36

Doc No: 10-AHL-F0008

Issue: 1.3

UL Report Number 4788294525-2aR01 Page 11 of 16

Page 12: Photometric Test Report...0.0006 Power Factor 0.995 Test Results Luminous Efficacy (lm/W) 4.1 Integrating Sphere Test for the lower CCT 1.The sample was tested according to the IES

6.0 THD and PF Test

Model No. Sample ID.

Temperature

(°C)Voltage (Vac) Frequency (Hz) Current (A) Power (W) Power Factor Current THD

25.1 120 60 2.6892 314.6 0.9949 8.43%

25.1 277 60 1.2021 310.5 0.9328 11.76%

1 1

Test Results

1. The samples were tested according to the ANSI C82.77-2014.

2. The ambient temperature condition was maintained at 25º C ± 1º C. The sample measurement was made using a digital power

meter and power supply. The sample was operated at rated voltage and stabilized before measurement. The total harmonic

distortion were calculated from thedigital power meter.

Test Method

33-LHB-14-7320-840-D-[S,N]-LP 1509809

Doc No: 10-AHL-F0008

Issue: 1.3

UL Report Number 4788294525-2aR01 Page 12 of 16

Page 13: Photometric Test Report...0.0006 Power Factor 0.995 Test Results Luminous Efficacy (lm/W) 4.1 Integrating Sphere Test for the lower CCT 1.The sample was tested according to the IES

7.0 In-Situ Temperature Measurement Test

Temperature

(°C)Voltage (Vac) Frequency (Hz) Current (A) Power (W) Power Factor Orientation

25.6 120.04 60 2.63 314.50 0.995 Horizontal

Test result column 1Test result (Correct to

25 °C)

TMP of LEDs 150 70.2 69.6

Ambient

temperatureN/A 25.6 25.0

Test result column 1Test result (Correct to

25 °C)

77.8 77.2

25.6 25.0

TMP location in LM-80 Report

Test Method

Test Results(LED)

1. In-Situ Temperature Measurement Test is conducted according to the UL1598-2008, Section 14.

2. The testing was conducted in a room with ambient temperature of 25°C ± 5°C. The apparatus construction followed those

described in UL1598-2008 for normal temperature testing. Thermocpuples were placed on the LED package in the locations

indicated by LM-80 report. The temperature was recorded after the lamp was operated by 3.5 hours in stability or by 7.5 hours.

In-Situ Temperature Measurement Test Conditions

LM-80 Limit Temp.

(°C)

Thermocouple

Location

Manufacturer

Declared Current

(mA)

Temperature for Lighting source

(°C) LED Model

Number

LM-80 Limit

Current

(mA)

105

Test Results(Driver)

Thermocouple Location

Temperature for Driver

(°C)Driver Model Number

Driver Limit Temp.

(°C)

TMP of DriverSYH-HP96-420230-VP 90

SPMWH1228FD5

WAT0SG160

Ambient temperature

Doc No: 10-AHL-F0008

Issue: 1.3

UL Report Number 4788294525-2aR01 Page 13 of 16

Page 14: Photometric Test Report...0.0006 Power Factor 0.995 Test Results Luminous Efficacy (lm/W) 4.1 Integrating Sphere Test for the lower CCT 1.The sample was tested according to the IES

7.0 In-Situ Temperature Measurement Test (Cont'd)

2 2

Test Photos for Ts Point of LED Packages

Doc No: 10-AHL-F0008

Issue: 1.3

UL Report Number 4788294525-2aR01 Page 14 of 16

Page 15: Photometric Test Report...0.0006 Power Factor 0.995 Test Results Luminous Efficacy (lm/W) 4.1 Integrating Sphere Test for the lower CCT 1.The sample was tested according to the IES

7.0 In-Situ Temperature Measurement Test (Cont'd)

2 2

Test Photos for Tc Point of LED Driver

Doc No: 10-AHL-F0008

Issue: 1.3

UL Report Number 4788294525-2aR01 Page 15 of 16

Page 16: Photometric Test Report...0.0006 Power Factor 0.995 Test Results Luminous Efficacy (lm/W) 4.1 Integrating Sphere Test for the lower CCT 1.The sample was tested according to the IES

****** END OF REPORT. THIS PAGE INTENTIONALLY LEFT BLANK ******

Doc No: 10-AHL-F0008

Issue: 1.3

UL Report Number 4788294525-2aR01 Page 16 of 16