phone: +82-2-551-3651 fax: +82-2-551-3650 tokin ... - kemet · features applications model *1 rated...

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data. ●Please request for a specification sheet for detailed product data prior to the purchase. ●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog. 9615NFSVOL14E1704E1 Noise Filters Vol. 14

Upload: others

Post on 25-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

For inquiry, Please call Product Management Department (Japan)Phone: +81-3-3515-9260 Fax: +81-3-3515-9261

Sales & Marketing Division, AsiaChiyoda First Bldg., 8-1, Nishi-Kanda 3-chome, Chiyoda-ku, Tokyo 101-8362, JapanPhone: +81-3-3515-9224 Fax: +81-3-3515-9223

Sales & Marketing Division, Americas and EuropeChiyoda First Bldg., 8-1, Nishi-Kanda 3-chome, Chiyoda-ku, Tokyo 101-8362, JapanPhone: +81-3-3515-9222 Fax: +81-3-3515-9223

TOKIN Korea Co., Ltd.518, Korea City AIR-Terminal B/D, 22, Teheran-ro 87 gil, Gangnam-gu, Seoul 06164, KoreaPhone: +82-2-551-3651 Fax: +82-2-551-3650

TOKIN America Inc. (Headquarters & Western Area Sales)2560 North First Street, Suite 100, San Jose, California 95131, U.S.A.Phone: +1-408-324-1790 Fax: +1-408-324-1497

Chicago Branch (Northeast Sales Office)1600 Golf Road, Corporate Center-Suite 1228, Rolling Meadows, Illinois 60008, U.S.A.Phone: +1-847-981-5047 Fax: +1-847-981-5051

Austin Branch (Southeast Sales Office)11782 Jollyville Road, Suite 208, Austin, Texas 78759, U.S.A.Phone: +1-512-219-4040 Fax: +1-512-219-4007

TOKIN Hong Kong Ltd.Unit Nos. 1513-1515, Level 15, Tower , Grand Central Plaza, 138 Shatin Rural Committee Road, Shatin, New Territories, Hong KongPhone: +852-2730-0028 Fax: +852-2375-2508

TOKIN Shanghai Co., Ltd.Room 301-303, Metro Plaza, No.555 Loushanguan Road, Changning District, Shanghai, China 200051Phone: +86-21-6228-0606 Fax: +86-21-6228-6862

Shenzhen BranchUnit 2659-2660, 26/F, Dong Fang Plaza, No.1072 Jian She Road, Luohu, Shenzhen City, Guangdong, China, 518001Phone: +86-755-2295-4481 Fax: +86-755-2295-4486

TOKIN Singapore Pte Ltd.150 Changi Road, #04-02 Guthrie Building, Singapore 419973Phone: +65-6345-3181 Fax: +65-6345-6016

TOKIN Taiwan Co., Ltd.Room 411, 4F, No.9, Lane 3, Minsheng W.Road, Taipei 104, TaiwanPhone: +886-2-2521-3998 Fax: +886-2-2521-3993

TOKIN Europe GmbHHellersbergstrasse 14, D-41460 Neuss, GermanyPhone: +49-2131-1866-0 Fax: +49-2131-1866-18

France BranchBâtiment FUJI YAMA, 1, avenue de l’Atlantique, 91940 LES ULIS, FrancePhone: +33-1-60-921137 Fax: +33-1-60-921146

©TOKIN Corporation 2017

Noise Filters

Vol.14

Page 2: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Contents

Casing TypeNew Products

LF-SF Series Three-Phase Type ...................................................................3

GT-SF Series Single-Phase Type ..................................................................4

Metal box

LF Series Small Current Type .......................................................................5

LF Series Small Current Type with Screw Terminal ......................................6

LF Series Screw Terminal Type.....................................................................8

LF Series Large Current Type .....................................................................10

LF Series Three-Phase Type.......................................................................11

LF Series For Inverters ...............................................................................13

LF Series Three-Phase Terminal Block Type ..............................................16

LH Series Low-Frequency Inverters ...........................................................18

LH Series Three-Phase Terminal Block / High Attenuation Type ...............20

HFP Series ..................................................................................................21

GT Series Screw Terminal ..........................................................................23

GT Series Faston Terminal .........................................................................25

GT Series For VCCI ....................................................................................27

GF Series ....................................................................................................28

Metal cylinder

VU Series ....................................................................................................29

VC Series ....................................................................................................31

VG-FPZ Series for inverter installed home appliances' surge control........32

RG Series ...................................................................................................33

Plastic box

MR Series ...................................................................................................35

MA Series ...................................................................................................37

Inlet TypeGL Series C Type ........................................................................................38

GL Series F, FV, FVP Type ..........................................................................40

GL Series H Type ........................................................................................42

GL Series M Type .......................................................................................44

TÜV Rheinland Japan Ltd. Certification Numbers .....................................45

Page 3: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.143

Casing TypePlastic box

LF-3100SF-10/20 520 10 2000 6000 1 50 -25~+100 UL, CSA, ENEC14 520 /540LF-3200SF-10/20 520 20 2000 6000 1 50 -25~+100 UL, CSA, ENEC14 520 /540LF-3300SF-10/20 520 30 2000 6000 1 50 -25~+100 UL, CSA, ENEC14 520 /540LF-3500SF-10/20 520 50 2000 6000 1 50 -25~+100 UL, CSA, ENEC14 950 /960

E

4

5

63

2

1

LINE LOAD

100

110

90

80

70

60

50

40

30

20

10

0

Inse

rtion

Los

s (d

B)

Frequency (MHz)0.1 0.5 1.0 5.0 10 20 30

Common mode

Normal mode

[mm]

B

E

F

G

H

A

3

1

2 LINE

6

LOAD

4

5

J JC

B

C

E

F

G

H

A

X

3

1

2 LINE

6

LOAD

4

5

150 50 78 140 32 4.3x5.5 1.5 M4 177 65 84 162 44 5.3x6.5 1.5 M5 150 50 78 140 32 4.3x5.5 1.5 M4 9.7 177 65 84 162 44 5.3x6.5 1.5 M5 9.7

A B C E F G H J X ModelNormal type 10,20,30ANormal type 50ADIN rail type 10,20,30ADIN rail type 50A

*1 : Model names ending with "10" indicate normal types, and those ending with "20" indicate DIN rail types. *2 : Normal type / DIN rail type (DIN rails not included in the products)

P Plastic shell of the product eliminates resin filling (weight reduction)

P DIN rail installation types available

P Featuring mechanism of self-jump-up to prevent loss of screw (easy to install)

P Safety cover integrating contact terminal

P Industrial equipment, machine tools

Features Applications

Model*1

Ratedvoltage

AC/DC (V)

Ratedcurrent

AC/DC (A)

Withstandingvoltage 2 sec.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.

Leakagecurrent

480V/50Hz,(mA) max.

Certifiedstandard

Weight(g)

Self-temperature

rise(K) max.

Operatingtemperature

range(°C) *2

*Recommended torque (N.m) max. RLine terminal (M4: 1.20, M5: 2.20) REarth terminal (M4: 1.20, M5: 2.20)

Shape and Dimensions

PLF-3**0SF-10 (Normal type) PLF-3**0SF-20 (DIN rail type)

Circuit Diagram

PCommon mode

PNormal mode

Measuring Circuit Attenuation (Static Characteristics)Representative example: 50A

Plastic Case Three-Phase Noise FilterLF-SF Series[RoHS Compliant]

Page 4: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.144

Casing TypePlastic box

GT-2060SF-10 250 6 1500 300 1 45 -25~+100 cCSAus,ENEC14 210GT-2100SF-10 250 10 1500 300 1 45 -25~+100 cCSAus,ENEC14 220GT-2160SF-10 250 16 1500 300 1 45 -25~+100 cCSAus,ENEC14 220GT-2200SF-10 250 20 1500 300 1 45 -25~+100 cCSAus,ENEC14 220

100

90

80

70

60

50

40

30

20

10

0

Inse

rtion

Los

s (d

B)

Frequency (MHz)0.1 0.5 1.0 5.0 10 20 30

Common mode

Normal mode

E

1

2

3

4

IN

Circuit Diagram

1

2

3

4

φ4.4

75

51

30.7

10

Earth connection:M4 screw

38

8.5

103

93

[mm]*Recommended torque (N.m) max. RLine terminal (M4: 1.00) REarth terminal (M4: 1.00)

Shape and Dimensions

P Plastic shell of the product eliminates resin filling (weight reduction)

P DIN rail installation types available

P Featuring mechanism of self-jump-up to prevent loss of screw (easy to install)

P Safety cover integrating contact terminal

P Industrial equipment, electronic devices

Features Applications

ModelRated

voltageAC/DC (V)

Ratedcurrent

AC/DC (A)

Withstandingvoltage 1 min.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.

Leakagecurrent

250V/60Hz,(mA) max.

Certifiedstandard

Weight(g)

Self-temperature

rise(K) max.

Operatingtemperature

range(°C)

Measuring Circuit

PCommon mode

PNormal mode

Attenuation (Static Characteristics)Representative example: 20A

Plastic Case Single-Phase Noise FilterGT-SF Series[RoHS Compliant]

Page 5: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.145

Casing TypeMetal box

LF-202A 250 2 1500 300 1 30 -20~+55 95LF-202U-1 250 2 1500 300 1 30 -20~+55 UL 95

IN E

P Z 0

Z 0

P: Power divider Z 0 : 50�

Z 0 : 50�

Z 0 Z 0

Z 0

Osc

illat

or EMI/EMCfilter

Leve

l met

erLe

vel m

eter

Osc

illat

or EMI/EMCfilter

Shape and Dimensions

�LF-202A, LF-202U-1

A10.0

B C

4.0 DEF

G 10.0

2-3.5ø

(Green/Yellow)

4.0

Label

Lead wireUL1015AWG#22 H

8.0

(Black)

(Black)(White)

(White)

LF-202A 100 32 17 48 56 64 100 25LF-202U-1 200 32 17 48 56 64 200 25

A B C D E F G H

[mm]

Model

PCommon mode

PNormal mode

Measuring Circuit

PLF-200 Series

Circuit Diagram

LF-202A Normal mode

LF-202A Common mode

100

80

60

40

20

0

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)0.1 0.5 1.0 5.0 10 20 30

Attenuation (Static Characteristics)

ModelRated

voltageAC/DC (V)

Ratedcurrent

AC/DC (A)

Leakagecurrent

250V/60Hz,(mA) max.

Certifiedstandard

Weight(g)

Self-temperature

rise(K) max.

Operatingtemperature

range(°C)

Withstandingvoltage 1 min.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.

LF SeriesSmall Current Type

[RoHS Compliant]

Page 6: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.146

Casing TypeMetal box

�LF-205A, LF-205P

�LF-215U

�LF-210, 210N, 210P, LF-215, 215N, 215P

IN E57 45 36 18

95105115

16 16

8-4.5ø

5-M4

25

50

�Label

40 30 24

637281

13.5 13.5

IN�

6-3.5ø

4-M3

15

33

57 36 IN�

95107115

16 1650

25

2-4.5ø

4-M4

Label

Label

�LF-205A, 205P, 215U

�LF-210, 215, 210P, 215P

�LF-210N, 215N

IN E

IN E

IN

[mm]

LF-205A 250 5 1500 300 1 30 -20~+55 170LF-205P 250 5 2000 300 1 30 -20~+55 170LF-210 250 10 1500 300 1 30 -20~+55 UL 590LF-215 250 15 1500 300 1 30 -20~+55 620LF-215U 250 15 1500 300 1 30 -20~+55 UL 620LF-210N 250 10 1500 300 1 30 -20~+55 650LF-210P 250 10 2000 300 1 30 -20~+55 590LF-215N 250 15 1500 300 1 30 -20~+55 650LF-215P 250 15 2000 300 1 30 -20~+55 620

LF SeriesSmall Current Type withScrew Terminal[RoHS Compliant]

*Recommended torque (N.m) max. RLine terminal (M3: 0.49)

*Recommended torque (N.m) max. RLine terminal (M4: 0.78)

*Recommended torque (N.m) max. RLine terminal (M4: 0.78)REarth terminal (M4: 1.18)

Shape and Dimensions

ModelRated

voltageAC/DC (V)

Ratedcurrent

AC/DC (A)

Leakagecurrent

250V/60Hz,(mA) max.

Certifiedstandard

Weight(g)

Self-temperature

rise(K) max.

Operatingtemperature

range(°C)

Withstandingvoltage 1 min.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.

Circuit Diagram

Page 7: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.147

Casing TypeMetal box

P Z 0

Z 0

P: Power divider Z 0 : 50� Z 0 : 50�

Z 0 Z 0

Z 0Osc

illat

or EMI/EMCfilter

Leve

l met

er

Leve

l met

er

Osc

illat

or EMI/EMCfilter

LF-205A Common mode

LF-205A Normal mode

LF-210 Normal mode

LF-210 Common mode

100

90

80

70

60

50

40

30

20

10

LF-215N Common mode

LF-215/215U Normal mode

LF-215N Normal mode

LF-215/215U Common mode

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

�LF-205A, LF-210

0.1 0.5 1.0 5.0 10 20 30

100

90

80

70

60

50

40

30

20

10

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

�LF-215, LF-215U, LF-215N

0.1 0.5 1.0 5.0 10 20 30

PCommon mode PNormal mode

Measuring Circuit

Attenuation (Static Characteristics)

Page 8: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.148

Casing TypeMetal box

�LF-220, 220N, 220P, LF-230, 230N, 230P

70 58 40

4-4.5ø

4-M6

M4

144160

130

29 29

IN�

60

30

70 58 40

29 29

IN�

�E

E

4-4.5ø4-M6

144130

160 60

30

Label

Label

�LF-230FU

E IN

IN

IN

E

P Z 0

Z 0

P: Power divider Z 0 : 50� Z 0 : 50�

Z 0 Z 0

Z 0Osc

illat

or EMI/EMCfilter

Leve

l met

er

Leve

l met

er

Osc

illat

or EMI/EMCfilter

[mm]

LF-220 250 20 1500 300 1 30 -20~+55 1.2LF-230 250 30 1500 300 1 30 -20~+55 1.2LF-230FU 250 30 1500 300 1 30 -20~+55 1.2LF-220N 250 20 1500 300 1 30 -20~+55 1.2LF-220P 250 20 2000 300 1 30 -20~+55 1.2LF-230N 250 30 1500 300 1 30 -20~+55 1.2LF-230P 250 30 2000 300 1 30 -20~+55 1.2

*Recommended torque (N.m) max. RLine terminal (M6: 1.18) REarth terminal (M4: 1.18)

Shape and Dimensions

Circuit Diagram

Measuring Circuit

ModelRated

voltageAC/DC (V)

Ratedcurrent

AC/DC (A)

Leakagecurrent

250V/60Hz,(mA) max.

Certifiedstandard

Weight(kg)

Self-temperature

rise(K) max.

Operatingtemperature

range(°C)

Withstandingvoltage 1 min.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.

PCommon mode

PLF-220, 220P, 230, 230P PLF-220N, 230N Series

PNormal mode

PLF-230FU

LF SeriesScrew Terminal Type[RoHS Compliant]

Page 9: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.149

Casing TypeMetal box

LF-220 Common mode

0.5

100

90

80

70

60

50

40

30

20

10

01 5 10 20 30

LF-230, LF-230FU Common mode

LF-230, LF-230FUNormal mode

LF-220 Normal mode

0.1

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

Attenuation (Static Characteristics)

Page 10: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1410

Casing TypeMetal box

LF-240 250 40 1500 300 1 40 -20~+45 3.2LF-240P 250 40 2000 300 1 40 -20~+45 3.2LF-250 250 50 1500 300 1 40 -20~+45 4.0LF-250P 250 50 2000 300 1 40 -20~+45 4.0LF-260N 250 60 1500 300 1 30 -20~+55 6.5LF-240U 250 40 1500 300 1 40 -20~+45 3.2

LF-240 Common mode

0.1

80

70

60

50

40

30

20

10

00.2 0.3 0.5 1.0 2.0 3.0 5.0 10 20

LF-250 Common mode

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

ModelRated

voltageAC/DC (V)

Ratedcurrent

AC/DC (A)

Leakagecurrent

250V/60Hz,(mA) max.

Certifiedstandard

Weight(kg)

Self-temperature

rise(K) max.

Operatingtemperature

range(°C)

Withstandingvoltage 1 min.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.

Attenuation (Static Characteristics)

�LF-240/240P/240U, LF-250/250P

�LF-260N

IN

2-6.5ø

M4

4-M6

2-6.5�9.0

FED

ABC

G G

H

I

315max.300±0.5285max.30max. 30max.

M6M4

(Earth)

2-4.5�7 oval hole 2-4.5ø

130m

ax.

115±

0.5

90max.

40±1.0

50±1

.0

Label G

IN�

Label E

Leve

l met

erP Z 0

Z 0

P: Power divider Z 0 : 50�

EMI/EMCfilter

Osc

illat

or

IN

E

IN

E

LF-240/240P 210 190 170 120 100 60 29 75 40 LF-240U 240 220 200 90 70 40 30 80 40 LF-250/250P 240 220 200 90 70 40 30 80 40 LF-260N 315 300 285 130 115 50 30 90 50

A B C D E F G H I

[mm]

Shape and Dimensions

PCommon mode

Circuit Diagram

Measuring Circuit

*Recommended torque (N.m) max. RLine terminal (M6: 1.18) REarth terminal (M4: 1.18)

PLF-260N Series

PLF-240, 240P, 240U, 250, 250P

Model

LF SeriesLarge Current Type[RoHS Compliant]

Page 11: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1411

Casing TypeMetal box

LF-305 250 5 1500 300 1 30 -20~+55 0.65LF-310 250 10 1500 300 1 30 -20~+55 UL 1.9LF-315 250 15 1500 300 1 30 -20~+55 1.9LF-320 250 20 1500 300 1 30 -20~+55 2.3LF-320U 250 20 1500 300 1 30 -20~+55 UL, CSA 2.4LF-330 250 30 1500 300 1 30 -20~+55 2.4LF-340 250 40 1500 300 1 40 -20~+45 5.3LF-350 250 50 1500 300 1 40 -20~+45 5.3LF-360 250 60 1500 300 1 40 -20~+45 8.0LF-305A 450 5 2000 300 2 40 -20~+45 0.65LF-310A 450 10 2000 300 2 40 -20~+45 1.9LF-315A 450 15 2000 300 2 40 -20~+45 1.9LF-320A 450 20 2000 300 2 40 -20~+45 UL 2.3LF-330A 450 30 2000 300 2 40 -20~+45 2.4LF-340A 450 40 2000 300 2 40 -20~+45 5.3LF-350A 450 50 2000 300 2 40 -20~+45 5.3

2-J K6-M46-M6(LF-320~360)

EFG

D D

BA

CC

HI

IN Label

IN

LF-305, 305A 120 110 40 25 80 95 110 25 45 4.5×7 4.5øLF-310, 310A 180 170 60 25 120 135 150 35 65 4.5×7 4.5øLF-315, 315A 180 170 60 25 120 135 150 35 65 4.5×7 4.5øLF-320, 320A 180 170 60 29 120 135 150 35 65 4.5×7 4.5øLF-320U 180 170 60 29 120 135 150 35 65 4.5×7 4.5øLF-330, 330A 180 170 60 29 120 135 150 35 65 4.5×7 4.5øLF-340, 340A 180 160 50 30 200 220 240 40 80 6.5×9 6.5øLF-350, 350A 180 160 50 30 200 220 240 40 80 6.5×9 6.5øLF-360 200 180 60 30 300 320 340 50 100 6.5×9 6.5ø

A B C D E F G H I J K

[mm]*Recommended torque (N.m) max. RLine terminal (M4: 0.78, M6: 1.18)

Shape and Dimensions

Circuit Diagram

ModelRated

voltageAC/DC (V)

Ratedcurrent

AC/DC (A)

Leakagecurrent

250V/60Hz,(mA) max.

Certifiedstandard

Weight(kg)

Self-temperature

rise(K) max.

Operatingtemperature

range(°C)

Withstandingvoltage 1 min.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.

Model

LF SeriesThree-Phase Type[RoHS Compliant]

Page 12: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1412

Casing TypeMetal box

P Z 0

Z 0

P: Power divider Z 0 : 50� Z 0 : 50�

Z 0 Z 0

Z 0

Z 0 Z 0 Z 0

Leve

l met

erEMI/EMCfilter

Osc

illat

or

Leve

l met

erEMI/EMCfilter

Osc

illat

or

LF-340 Common mode

LF-330 Common mode

LF-340Normal mode

LF-350 Normal mode

LF-360 Normal mode

LF-360 Common mode

LF-350 Common mode

80

LF-320 Normal mode70

60

50

40

30

20

10

0

LF-305 Common mode

LF-310Common mode

100

90

80

70

60

50

40

30

20

10

0

LF-315 Normal mode

LF-320 Common mode

LF-315 Common mode

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)0.1 0.2 0.4 0.6 0.8 1 2 4 6 8 10 20 0.1 0.5 1.0 5.0 10 20 30

100

90

80

70

60

50

40

30

20

10

0

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)0.1 0.5 1.0 5.0 10 20 30

100

90

80

70

60

50

40

30

20

10

0

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)0.1 0.5 1.0 5.0 10 20 30

LF-330Normal mode

PCommon mode PNormal mode

Measuring Circuit

Attenuation (Static Characteristics)

Page 13: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1413

Casing TypeMetal box

LF-305 250 5 1500 300 1 -20~+55 � (input side)LF-310 250 10 1500 300 1 -20~+55 UL � (input side)LF-315 250 15 1500 300 1 -20~+55 � (input side)LF-320 250 20 1500 300 1 -20~+55 � (input side)LF-330 250 30 1500 300 1 -20~+55 � (input side)LF-340 250 40 1500 300 1 -20~+45 � (input side)LF-350 250 50 1500 300 1 -20~+45 � (input side)LF-360 250 60 1500 300 1 -20~+45 � (input side)LF-305G 250 5 1500 300 1 -25~+55 � (input side)LF-310G 250 10 1500 300 1 -25~+55 � (input side)LF-320G 250 20 1500 300 1 -25~+55 � (input side)LF-315K 250 15 2000 300 5 -25~+55 � (input side)LF-325K 250 25 2000 300 5 -25~+55 � (input side)LF-335K 250 35 2000 300 5 -25~+55 � (input side)LF-380K 250 80 2000 300 5 -25~+55 � (input side)LF-314K4 506 14 2500 300 10 (500V, 60Hz) -25~+55 � (input side)LF-330K4 506 30 2500 300 10 (500V, 60Hz) -25~+55 � (input side)LF-355K4 506 55 2500 300 10 (500V, 60Hz) -25~+55 � (input side)LF-380K4 506 80 2500 300 10 (500V, 60Hz) -25~+55 � (input side)LF-310KA 250 10 2000 300 — -25~+55 � (output side)LF-320KA 250 20 2000 300 — -25~+55 � (output side)LF-350KA 250 50 2000 300 — -25~+55 � (output side)LF-310KB 440 10 2500 300 — -25~+55 � (output side)LF-320KB 440 20 2500 300 — -25~+55 � (output side)LF-335KB 440 35 2500 300 — -25~+55 � (output side)LF-345KB 440 45 2500 300 — -25~+55 � (output side)LF-375KB 440 75 2500 300 — -25~+55 � (output side)LF-3110KB 440 110 2500 300 — -25~+55 � (output side)

ModelRated

voltageAC/DC (V)

Ratedcurrent

AC/DC (A)

Leakagecurrent

250V/60Hz,(mA) max.

Certifiedstandard

Installationposition

Operatingtemperature

range(°C)

Withstandingvoltage 1 min.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.

N / F� N / F�R S T

U V W

General-purposeinverter

MotorLine

M

N/F� LF-K Series (conforms to CISPR Pub 14) LF Series (conforms to FCC P15-J and JTTC) LF-G Series (conforms to FCC P15-J and JTTC) N/F� LF-KA Series (200V line) LF-KB Series (400V line)

Installation Diagram

Only LF-KA and KB can be used in N/F�.Caution

LF SeriesFor Inverters[RoHS Compliant]

Page 14: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1414

Casing TypeMetal box

P Z 0

Z 0

P: Power divider Z 0 : 50� Z 0 : 50�

Z 0 Z 0

Z 0

Z 0 Z 0 Z 0

Leve

l met

erEMI/EMCfilter

Osc

illat

or

Leve

l met

erEMI/EMCfilter

Osc

illat

or

2-J2-4.5ø (LF-305~330)2-6.5ø (LF-340~360)

6-M4M6(LF-320

~LF-360)

IN

EFG

D D

BA

HI

CC

A1±2.0A2±0.5A3±1.02-4.5�7 oval hole

M4

2-4.5øB1

±2.0

B2±0

.5B3±1

.0B3

±1.0

C1±2.0C2±1.0

IN

�� �

Label

Label

ECA

G HF

DB

A4 A4

Measuring Circuit

Shape and Dimensions

*Recommended torque (N.m) max. RLine terminal (M4: 1.86, M6: 5.78, M8: 10.29)

PLF-300 Series

PLF-G Series

PLF-K Series

PCommon mode PNormal mode

[mm]

LF-305 120 110 40 25 80 95 110 25 45 4.5×7LF-310 180 170 60 25 120 135 150 35 65 4.5×7LF-315 180 170 60 25 120 135 150 35 65 4.5×7LF-320 180 170 60 29 120 135 150 35 65 4.5×7LF-330 180 170 60 29 120 135 150 35 65 4.5×7LF-340 180 160 50 30 200 220 240 40 80 6.5×9LF-350 180 160 50 35 200 220 240 40 80 6.5×9LF-360 200 180 60 30 300 320 340 40 100 6.5×9

A B C D E F G H I JModel

[mm]

LF-305G 110 95 80 25 120 110 40 45 25LF-310G 150 135 120 25 120 110 40 65 35LF-320G 150 135 120 25 120 110 40 65 35

A1 A2 A3 A4 B1 B2 B3 C1 C2Model

[mm]

200V

line

400V

line

LF-315K TE-K5.5 M4 260 180 180 160 120 65 7×4.5ø 4.5øLF-325K TE-K22 M6 340 180 260 160 200 80 9×6.5ø 6.5øLF-335K TE-K22 M6 440 200 360 180 300 100 9×6.5ø 6.5øLF-380K TE-K22 M6 670 400 560 380 500 170 9×6.5ø 6.5øLF-314K4 TE-K5.5 M4 260 180 180 160 120 65 7×4.5ø 4.5øLF-330K4 TE-K22 M6 440 200 360 180 300 100 9×6.5ø 6.5øLF-355K4 TE-K22 M6 540 300 470 270 400 130 9×6.5ø 6.5øLF-380K4 TE-K22 M6 672 400 560 380 500 170 9×6.5ø 6.5ø

A B C D E F G HModel Terminal board

[mm]

200V

line

400V

line

LF-310KA TE-K5.5 M4 140 100 100 90 70 45 7×4.5ø 4.5øLF-320KA TE-K5.5 M4 140 100 100 90 70 45 7×4.5ø 4.5øLF-350KA TE-K22 M6 260 180 180 160 120 65 7×4.5ø 4.5øLF-310KB TE-K5.5 M4 140 100 100 90 70 45 7×4.5ø 4.5øLF-320KB TE-K5.5 M4 140 100 100 90 70 45 7×4.5ø 4.5øLF-335KB TE-K5.5 M4 140 100 100 90 70 45 7×4.5ø 4.5øLF-345KB TE-K22 M6 260 180 180 160 120 65 7×4.5ø 4.5øLF-375KB TE-K22 M6 540 320 480 300 340 240 9×6.5ø 6.5øLF-3110KB TE-K60 M8 540 320 480 300 340 240 9×6.5ø 6.5ø

A B C D E F G HTerminal boardModel

Page 15: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1415

Casing TypeMetal box

100

LF-320 Normal mode90

80

70

60

50

40

30

20

10

0

LF-315 Normal mode

LF-320Common mode

LF-315Common mode

LF-340 Common mode

LF-330 Common mode

LF-330Normal mode

LF-340Normal mode

LF-350 Normal mode

LF-360 Normal mode

LF-360Common mode

LF-350Common mode

90

80

70

60

50

40

30

20

10

LF-320GCommon mode LF-310G

Common mode

LF-305GCommon mode

LF-335KCommon mode

LF-315KCommon mode

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)0.1 0.5 1.0 5.0 10 20 30

100

90

80

70

60

50

40

30

20

10

0

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)0.1 0.5 1.0 5.0 10 20 30

100

90

80

70

60

50

40

30

20

10

0

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)0.1 0.5 1.0 5.0 10 20 30 0.15

00.5 1.0 5.0 10.0 30.0

90

80

70

60

50

40

30

20

10

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)0.150

0.5 1.0 5.0 10.0 30.0

IN

1

2

3

1

2

3

4

5

6

4

5

6

1

2

3

4

5

6

Circuit Diagram

PLF-300 Series

PLF-G Series

PKA, KB Series

PK, K4 Series

Attenuation (Static Characteristics)

Page 16: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1416

Casing TypeMetal box

LF-3200 250 20 2000 300 1.2 30 -25~+55 TÜVLF-3300 250 30 2000 300 1.2 30 -25~+55 TÜVLF-3400 250 40 2000 300 1.2 30 -25~+55 TÜVLF-3500 250 50 2000 300 1.2 30 -25~+55 TÜVLF-3600 250 60 2000 300 1.2 30 -25~+55 TÜV

ModelRated

voltageAC/DC (V)

Ratedcurrent

AC/DC (A)

Leakagecurrent

250V/60Hz,(mA) max.

Certifiedstandard

Self-temperature

rise(K) max.

Operatingtemperature

range(°C)

Withstandingvoltage 1 min.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.

L1L2

L3

1 IN2

3

4 OUT

5

6

NOISE FILTER

MADE IN JAPAN

DCBA0.5

4-C2

4-ø6

M

N

G1.

0F0

.5E H

J K L

I

1

2

3

E

4

5

6

[mm]

LF-3200 150 180 219 247 90 100 110 32 17 45.5 47.5 60 M5 M5LF-3300 150 180 219 247 90 100 110 32 17 45.5 47.5 60 M5 M5LF-3400 150 180 237 264 129 139 149 46 24 58.5 63 75 M6 M6LF-3500 150 180 237 264 129 139 149 46 14 48.5 53 60 M6 M6LF-3600 300 330 387 414 180 200 220 46 55 89.5 94 115 M6 M6

A B C D E F G H I J K L M N

P Z 0

Z 0

P: Power divider Z 0 : 50�

Z 0

Leve

l met

erEMI/EMCfilter

Osc

illat

or

*Recommended torque (N.m) max. RLine terminal (M5: 3.33, M6: 5.78) REarth terminal (M5: 3.33, M6: 5.78)

Shape and Dimensions

Circuit Diagram Measuring Circuit

PCommon mode

Model

LF SeriesThree-Phase Terminal Block Type

[RoHS Compliant]

TÜV Rheinland

Page 17: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1417

Casing TypeMetal box

100

50

00.1 1.0 10 30

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

LF-3200100

50

0

LF-3300

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)0.1 1.0 10 30

100

50

00.1 1.0 10 30

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

100

50

00.1 1.0 10 30

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

LF-3500LF-3400

100

50

00.1 1.0 10 30

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

LF-3600

Attenuation (Static Characteristics)

Page 18: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1418

Casing TypeMetal box

IN

BFD

øHG

E

Pan-head screw

A

C

H

Label

[mm]

LH-3102 250 10 2000 300 1 40 -20~+45LH-3152 250 15 2000 300 1 40 -20~+45LH-3202 250 20 2000 300 1 40 -20~+45LH-3302 250 30 2000 300 1 40 -20~+45LH-3402 250 40 2000 300 1 40 -20~+45LH-3502 250 50 2000 300 1 40 -20~+45LH-3602 250 60 2000 300 1 40 -20~+45LH-3702 250 70 2000 300 1 40 -20~+45LH-3802 250 80 2000 300 1 40 -20~+45

LH-3102 105 182 70 230 max. 80 200 M4 4.5LH-3152 105 182 70 230 max. 80 200 M4 4.5LH-3202 105 182 70 230 max. 80 200 M4 4.5LH-3302 115 203 85 250 max. 75 220 M6 5.5LH-3402 115 203 85 250 max. 75 220 M6 5.5LH-3502 190 300 125 355 max. 150 320 M6 5.5LH-3602 190 300 125 355 max. 150 320 M6 5.5LH-3702 190 335 155 430 max. 150 360 M8 5.5LH-3802 190 335 155 430 max. 150 360 M8 5.5

A B C D E F G H

P Z 0

Z 0

P: Power divider Z0 : 50� Z 0 : 50�

Z 0 Z 0

Z 0

Z 0 Z 0 Z 0

Leve

l met

erEMI/EMCfilter

Osc

illat

or

Leve

l met

erEMI/EMCfilter

Osc

illat

or

*Recommended torque (N.m) max. RLine terminal (M4: 0.78, M6: 1.18, M8: 2.65)

Shape and Dimensions

Circuit Diagram

Measuring Circuit

ModelRated

voltageAC/DC (V)

Ratedcurrent

AC/DC (A)

Leakagecurrent

250V/60Hz,(mA) max.

Self-temperature

rise(K) max.

Operatingtemperature

range(°C)

Withstandingvoltage 1 min.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.

PCommon mode PNormal mode

ModelPLH Series

LH SeriesLow-Frequency Inverters[RoHS Compliant]

Page 19: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1419

Casing TypeMetal box

0.15 0.5 1.0 5.0 10.0 30.0

90

LH-3402Common mode

100

80

70

60

50

40

30

20

10

0

LH-3402Normal mode

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

Attenuation (Static Characteristics)

Page 20: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1420

Casing TypeMetal box

LH-3304 250 30 2000 300 1.2 30 -25~+55 TÜVLH-3404 250 40 2000 300 1.2 30 -25~+55 TÜVLH-3604 250 60 2000 300 1.2 30 -25~+55 TÜVLH-3804 250 80 2000 300 1.2 30 -25~+55 TÜVLH-31204 250 120 2000 300 1.2 30 -25~+55 TÜVLH-31504 250 150 2000 300 1.2 30 -25~+55 TÜV

Common mode100

50

00.1 1 10 30

LH-3304

Inse

rtio

n L

oss

(dB

)

Frequency (MHz)

ModelRated

voltageAC/DC (V)

Ratedcurrent

AC/DC (A)

Leakagecurrent

250V/60Hz,(mA) max.

Certifiedstandard

Self-temperature

rise(K) max.

Operatingtemperature

range(°C)

Withstandingvoltage 1 min.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.

Attenuation (Static Characteristics)

1

2

3

4

5

6

OUTIN P Z 0

Z 0

P: Power divider Z0 : 50�

Z 0

Leve

l met

erEMI/EMCfilter

Osc

illat

or

PCommon mode

Circuit Diagram Measuring Circuit

L1L2

L3

1 IN2

3

4 OUT

5

6

NOISE FILTER

MADE IN JAPAN

CBA

4-C2

4-ø6

F E D G I J K

H

L

M

LH-3304 250 280 349 90 100 110 32 17 45.5 47.5 85 M5 M5LH-3404 250 280 366 129 139 149 46 23 58 62 85 M6 M6LH-3604 306 336 422 160 170 180 46 55 90 94 160 M6 M6LH-3804 450 480 600 210 230 250 56 60 103 107 170 M8 M8LH-31204 480 510 630 222 242 262 56 60 103 107 170 M8 M8LH-31504 630 660 788 250 270 290 76 70 126 130 200 M10 M10

A B C D E F G H I J K L M

[mm]

Shape and Dimensions

*Recommended torque (N.m) max. RLine terminal (M5: 3.33, M6: 5.78, M8: 10.29, M10: 19.1) REarth terminal (M5: 3.33, M6: 5.78, M8: 10.29, M10: 19.1)

Model

LH SeriesThree-Phase Terminal Block / High Attenuation Type[RoHS Compliant]

TÜV Rheinland

Page 21: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1421

Casing TypeMetal box

HFP-2153 250 15 AC1500 10 1.5 (250V, 60Hz) 30 -20~+55 UL,CSA,TÜV 0.64HFP-2303 250 30 AC1500 10 1.5 (250V, 60Hz) 30 -20~+55 UL,CSA,TÜV 1.3

ModelRated

voltageAC/DC (V)

Ratedcurrent

AC/DC (A)

Leakagecurrent

(mA) max.Certifiedstandard

Weight(kg)

Self-temperature

rise(K) max.

Operatingtemperature

range(°C)

Withstandingvoltage 1 min.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.

8-4.5ø

5-M4IN

�E

95105115

5016 16

57 45 36 18

25 130144160

70 58 4029 29 60

30

4-4.5ø

4-M6

M4Label IN

�ELabel

�HFP-2153 �HFP-2303

[mm]*Recommended torque (N.m) max. RLine terminal (M4: 0.78, M6: 1.18) REarth terminal (M4: 1.18)

Shape and Dimensions

�HFP-2153, 2303

IN OUT

Circuit Diagram

PZ 0

Z 0

P : Power divider Z 0 : 50� Z 0 : 50�

Z 0 Z 0

100V50Hz

NoisesimulatorHTG2121

50� 50�

50�VoOscillo-scope

Vi

Leve

l met

er

Osc

illat

or

EMI/EMCfilter

Osc

illat

or

Leve

l met

erEMI/EMCfilter

EMI/EMCfilter

Measuring Circuit

PCommon mode PNormal mode PPulse characteristic measuring circuit

HFP Series[RoHS Compliant]

TÜV Rheinland

Page 22: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1422

Casing TypeMetal box

80

100

60

40

20

0

HFP-2303 Common mode

HFP-2153 Common mode

HFP-2303 Normal mode

HFP-2153 Normal mode

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)0.15 1.0 10 30

70

60

50

40

30

20

10

0

HFP-2153

HFP-2303

Out

put p

ulse

pea

k vo

ltage

(V

)

Input pulse peak voltage (V)200 400 600 800 1000 1200 1400 1600 1800 2000

Attenuation (Static Characteristics)

Pulse Attenuation Example

Page 23: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1423

Casing TypeMetal box

ModelRated

voltageAC (V)

RatedcurrentAC (A)

Leakagecurrent

250V/60Hz,(mA) max.

Certifiedstandard

Weight(g)

Self-temperature

rise(K) max.

Operatingtemperature

range(°C)

Withstandingvoltage 1 min.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.

500

200

100

50

20

10

5

2

1

GT-2200

GT-2050

GT-2150

IN E

IN E

Out

put p

ulse

pea

k vo

ltage

(V

)

Input pulse peak voltage (V)

�Pulse Attenuation Example

0 200 400 600 800 1000 1200

GT-2200RGT-2150RGT-2100RGT-2050R

GT-2100

Circuit Diagram

PGT-2000 Series, GT-2000R Series

PGT-200U Series

�GT-2100, GT-210U, GT-2150, GT-215U, GT-2200 GT-220U, GT-2150R, GT-2100R, GT-2200R

�GT-2050, GT-205U, GT-2050R

39

25

11

50.8

29 max.

10

17

20.574.7

20.563.5

84

5-M4

2-4.8ø

24Label E 2660.5

4.8ø 15.5 53max. 15.5 5-M4

53m

ax.

70

4.8�6.8*

LabelE

[mm]*Recommended torque (N.m) max. RLine terminal (M4: 0.78) REarth terminal (M4: 1.18)

Shape and Dimensions

*ø4.8 for GT-205U

GT SeriesScrew Terminal[RoHS Compliant]

TÜV Rheinland

* : Also supports DC input.

GT-2050 250 5 1500 300 0.5 35 -20~+55 150GT-2100 250 10 1500 300 0.5 35 -20~+55 260GT-2150 250 15 1500 300 0.5 35 -20~+55 270GT-2200 250 20 1500 300 0.5 35 -20~+55 270GT-205U 250 5 1500 300 0.5 35 -20~+55 UL, TÜV, VDE, CSA 170GT-210U 250 10 1500 300 0.5 35 -20~+55 UL, TÜV, VDE, CSA 260GT-215U 250 15 1500 300 0.5 35 -20~+55 UL 270GT-220U 250 20 1500 300 0.5 35 -20~+55 UL, TÜV 270GT-2050R 250 5 1500 300 0.5 35 -20~+55 160GT-2100R 250 10 1500 300 0.5 35 -20~+55 270GT-2150R 250 15 1500 300 0.5 35 -20~+55 280GT-2200R 250 20 1500 300 0.5 35 -20~+55 285

******

****

Page 24: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1424

Casing TypeMetal box

100

GT-205U, 2050 Normal mode

90

80

70

60

50

40

30

20

10

0

GT-205U, 2050 Common mode

GT-210U, 2100 Normal mode

GT-210U, 2100 Common mode

GT-215U, 2150 Normal mode

GT-215U, 2150 Common mode

GT-220U, 2200 Normal mode

GT-220U, 2200 Common mode

0.1 0.5 1.0 5.0 10 20 30

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

�GT-205U, GT-2050100

90

80

70

60

50

40

30

20

10

00.1 0.5 1.0 5.0 10 20 30

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

�GT-210U, GT-2100

100

90

80

70

60

50

40

30

20

10

00.1 0.5 1.0 5.0 10 20 30

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

�GT-220U, GT-2200100

90

80

70

60

50

40

30

20

10

00.1 0.5 1.0 5.0 10 20 30

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

�GT-215U, GT-2150

GT-2150R Common mode

GT-2150R Normal mode

GT-2200R Common mode

GT-2200R Normal mode

100

90

80

70

60

50

40

30

20

10

0

GT-2050R Common mode

GT-2050R Normal modeGT-2100R Common mode

GT-2100R Normal mode

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

�GT-2050R

0.1 0.5 1.0 5.0 10 20 30

100

90

80

70

60

50

40

30

20

10

0

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

�GT-2100R

0.1 0.5 1.0 5.0 10 20 30

100

90

80

70

60

50

40

30

20

10

0

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

�GT-2200R

0.1 0.5 1.0 5.0 10 20 30

100

90

80

70

60

50

40

30

20

10

0

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

�GT-2150R

0.1 0.5 1.0 5.0 10 20 30

P Z 0

Z 0

P: Power divider Z0: 50� Z 0 : 50�

Z 0 Z 0

100v

50Hz

NoisesimulatorHTG2121

Vi

50�

50� VoOscillo-scopeLe

vel m

eter

EMI/EMCfilter

Osc

illat

or

EMI/EMCfilter

Osc

illat

or

Leve

l met

er EMI/EMCfilter

Attenuation (Static Characteristics)

Measuring Circuit

PCommon mode PNormal mode PPulse-characteristic measuring circuit

Page 25: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1425

Casing TypeMetal box

GT-205J * 250 5 1500 300 0.5 35 -25~+55 UL, CSA, TÜV, VDE 135GT-210J * 250 10 1500 300 0.5 35 -20~+55 UL, CSA, TÜV, VDE 240GT-215J * 250 15 1500 300 0.5 35 -25~+50 UL, CSA, TÜV, VDE 255GT-20301 250 3 1500 300 1.0 30 -25~+55 UL, CSA, TÜV 160GT-20601 250 6 1500 300 1.0 30 -25~+55 UL, CSA, TÜV 190GT-21001 250 10 1500 300 1.0 30 -25~+55 UL, CSA, TÜV 300GT-20302 250 3 1500 300 1.0 30 -20~+55 UL, CSA, TÜV 215

�GT-210J, GT-215J �GT-205J

C

B

D

E

A

#250 Faston® tab

2-4.8ø

51.3

10

38

25

Faston® tab

� �

� �

53max.

60.571.5

26

2-4.5ø

10

5 #250

E

89

53m

ax.

Label

84

74.7

63.5

E

1919

Label

29.5

2-4.8ø

29

EIN

�EIN

[mm]

GT-20301 93.0 53.0 30.0 74.7 85.0GT-20601 105.5 57.5 32.0 87.0 96.5GT-21001 105.5 57.5 44.5 87.0 96.5GT-20302 93.0 53.0 46.0 74.7 84.3

A B C D E

Shape and Dimensions

Circuit Diagram

RatedvoltageAC (V)

RatedcurrentAC (A)

Leakagecurrent

250V/60Hz,(mA) max.

Certifiedstandard

Weight(g)

Self-temperature

rise(K) max.

Operatingtemperature

range(°C)

Withstandingvoltage 1 min.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.Model

PGT-J, 01 Type PGT-02 Type

*Faston® is a registered trademark of Tyco Electronics AMP.

Model

* : Also supports DC input.

PGT-01,02 Type

GT SeriesFaston Terminal[RoHS Compliant]

TÜV Rheinland

Page 26: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1426

Casing TypeMetal box

GT-205J Normal mode

100

90

80

70

60

50

40

30

20

10

0

GT-210J Normal mode

GT-215J Normal mode

GT-215J Common mode

GT-205J Common mode

GT-210J Common mode

80

60

40

20

500

200

100

50

20

10

5

2

1

GT-205JGT-215J

GT-210J

GT-01Common mode

GT-01Normal mode

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

V0

outp

ut (

V)

Input pulse peak voltage (V)

�Pulse Attenuation Example

0.1 0.5 1.0 5.0 10 20 30

0.01 0.05 0.1 0.5 15 10 30

1 200 400 600 800 1000 1200

GT-20302Common mode

GT-20302Normal mode

P Z 0

Z 0

P: Power divider Z 0 : 50� Z 0 : 50�

Z 0

Z 0 Z 0

NoisesimulatorHTG2121

50�

50� VoOscillo-scope

100v

50Hz

Vi

Leve

l met

er

EMI/EMCfilter

Osc

illat

orEMI/EMCfilter

Osc

illat

or

Leve

l met

er

EMI/EMCfilter

Attenuation (Static Characteristics)

Measuring Circuit

PCommon mode PNormal mode PPulse-characteristic measuring circuit

Page 27: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1427

Casing TypeMetal box

GT-20501V 250 5 1500 300 0.5 35 -20~+55 220GT-21001V 250 10 1500 300 0.5 35 -20~+55 UL, CSA, TÜV 280GT-22001V 250 20 1500 300 0.5 35 -20~+55 UL, TÜV 285

P Z 0

Z 0

P: Power divider Z 0 : 50� Z 0 : 50�

Z 0 Z 0

Z 0

Leve

l met

er

EMI/EMCfilter

Osc

illat

or

Leve

l met

er

EMI/EMCfilter

Osc

illat

or

IN

E

50.8

39

25

11

74.763.520.5 20.5

84

24

5-M4

2-4.8ø

E

[mm]

Normal mode

100

80

60

40

20

0

Common mode

0.01 0.1 1.0 10 30

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

�GT-21001V

Shape and Dimensions

RatedvoltageAC (V)

RatedcurrentAC (A)

Leakagecurrent

250V/60Hz,(mA) max.

Certifiedstandard

Weight(g)

Self-temperature

rise(K) max.

Operatingtemperature

range(°C)

Withstandingvoltage 1 min.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.Model

PCommon mode PNormal mode

Circuit Diagram

Measuring Circuit

Attenuation (Static Characteristics)

*Recommended torque (N.m) max. RLine terminal (M4: 0.78) REarth terminal (M4: 1.18)

PGT-V Series

GT SeriesFor VCCI[RoHS Compliant]

TÜV Rheinland

Page 28: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1428

Casing TypeMetal box

GF-2050 250 5 1500 300 1 30 -20~+55 130GF-205U 250 5 1500 300 1 30 -20~+60 UL 130GF-2100 250 10 1500 300 1 30 -20~+55 140GF-210U 250 10 1500 300 1 30 -20~+60 UL 140GF-2150 250 15 1500 300 1 30 -20~+55 140GF-2200 250 20 1500 300 1 30 -20~+55 150GF-220U 250 20 1500 300 1 30 -20~+60 UL 150GF-205E 250 5 1500 300 1 30 -20~+55 CSA 130

GF-205U

100

80

60

40

20

0

GF-210U

GF-205E

GF-220U

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)0.2 0.4 0.8 1 2 64 8 10 20 30

ModelRated

voltageAC/DC (V)

Ratedcurrent

AC/DC (A)

Leakagecurrent

250V/60Hz,(mA) max.

Certifiedstandard

Weight(g)

Self-temperature

rise(K) max.

Operatingtemperature

range(°C)

Withstandingvoltage 1 min.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.

Attenuation (Static Characteristics)

53max. 16 164.8�6.8*

4.8ø5-M4

10

53m

ax.

60.570

2917

53max89

53m

ax60

.571

.5

10.02-4.5ø

26 20

32max.25

5 Faston® tab #250

*4.8ø for UL devices

Label

Label

E

�E

P Z 0

Z 0

P: Power divider Z 0 : 50�

Leve

l met

er

EMI/EMCfilter

Osc

illat

or

IN E

[mm]

Shape and Dimensions

PCommon mode

Circuit Diagram

Measuring Circuit

*Recommended torque (N.m) max. RLine terminal (M4: 0.78) REarth terminal (M4: 1.18)

PGF Series (Except Type E)

PGF-E Type

Common mode

GF Series[RoHS Compliant]

Page 29: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1429

Casing TypeMetal cylinder

VU-210FA 250 10 1500 300 1 40 -25~+55 UL, CSA 130VU-215F 250 15 1500 300 1 40 -25~+55 UL, CSA 130VU-215F3 250 15 1500 300 1 40 -25~+55 UL, CSA 105VU-215FE 250 15 1500 300 1 40 -25~+55 UL, CSA 130VU-220F 250 20 1500 300 1 40 -25~+55 UL, CSA, TÜV 240

�VU-215F, VU-215F3, VU-220F, 210FA �VU-215FE

BA C D

M8�1.25

4-Faston® tab terminal#250

� M8�1.25

BA C D

E

Label

4-Faston® tab terminal#250

Label

E

IN E

IN

IN

E

�VU-210FA, 215F, 220F �VU-215FE

�VU-215F3

[mm]

VU-215F 12 50 12 38VU-215F3 12 40 13 45VU-215FE 12 50 12 38VU-220F, 210FA 12 50 12 50

A B C D

Shape and Dimensions

ModelRated

voltageAC/DC (V)

Ratedcurrent

AC/DC (A)

Leakagecurrent

250V/60Hz,(mA) max.

Certifiedstandard

Weight(g)

Self-temperature

rise(K) max.

Operatingtemperature

range(°C)

Withstandingvoltage 1 min.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.

Circuit Diagram

*Recommended torque (N.m) max. REarth terminal (M8: 4.41) *Faston® is a registered trademark of Tyco Electronics AMP.

Model

TÜV RheinlandVU Series[RoHS Compliant]

Caution: E represents a screw installation portion (M8).

Page 30: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1430

Casing TypeMetal cylinder

P Z 0

Z 0

P: Power divider Z 0 : 50� Z 0 : 50�

Z 0 Z 0

Z 0

Leve

l met

er

EMI/EMCfilter

Osc

illat

or

Leve

l met

er

Osc

illat

or

EMI/EMCfilter

VU-220F Common mode100

90

80

70

60

50

40

30

20

10

0

VU-215F3 Common mode

VU-210FA Common mode

VU-210FA Normal mode

VU-215F3 Normal mode

VU-220F Normal mode

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)0.1 0.5 1.0 5.0 10 20 30

PCommon mode

Measuring Circuit

Attenuation (Static Characteristics)

PNormal mode

Page 31: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1431

Casing TypeMetal cylinder

Normal mode

70

60

50

40

30

20

10

0

Common mode

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

�VC-210FA

0.1 0.3 0.5 1 3 5 10 30

VC-210FA 250 10 1500 300 1.5 40 -20~+55 VDE 130VC-215F3V 250 15 1500 300 1.5 40 -20~+55 TÜV 110

Attenuation (Static Characteristics)

ModelRated

voltageAC/DC (V)

Ratedcurrent

AC/DC (A)

Leakagecurrent

250V/60Hz,(mA) max.

Certifiedstandard

Weight(g)

Self-temperature

rise(K) max.

Operatingtemperature

range(°C)

Withstandingvoltage 1 min.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.

�VC-210FA �VC-215F3V

Label Label

4-Faston® tab terminal #250

E

M8BA C D

��

M8

E

A B C D

4-Faston® tab terminal #250

[mm]

VC-210FA 12 70 12 38VC-215F3V 12 60 12 38

A B C D

Shape and Dimensions

*Faston® is a registered trademark of Tyco Electronics AMP.*Recommended torque (N.m) max. REarth terminal (M8: 4.41)

Model

P Z 0Z 0

P: Power divider Z 0 : 50�

Z 0 : 50�

Z 0 Z 0Z 0

Leve

l met

er

EMI/EMCfilter

Osc

illato

r

Leve

l met

er

Osc

illato

r

EMI/EMCfilter

Measuring Circuit

PCommon mode

PNormal mode

VC Series[RoHS Compliant]

TÜV Rheinland

INE

Circuit Diagram

PVC Series

Caution: E represents a case.

Page 32: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1432

Casing TypeMetal cylinder

VG-2150FPZ-10 100 15 1000 300 0.5 (125V) -25~+55 200VG-2150FPZ-20 200 15 1500 300 1.0 (250V) -25~+55 200VG-2200FPZ-10 100 20 1000 300 0.5 (125V) -25~+55 220

Z+SA

CyZ

Cx L

Cx

R

E

5013

4 3

2 1

7.0

11

Case grounding

#250Faston® terminal

1370

100VAC 15A

VG-2150FPZ-10

Lot No.

[mm]

100

50

0

VG-2150FPZ-10, VG-2200FPZ-10

VG-2150FPZ-20

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)0.15 1 10 30

Shape and Dimensions

ModelRated

voltageAC/DC (V)

Ratedcurrent

AC/DC (A)

Leakagecurrent

250V/60Hz,(mA) max.

Weight(g)

Operatingtemperature

range(°C)

Withstandingvoltage 1 min.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.

Circuit Diagram

Attenuation Characteristics

Common mode

*Faston® is a registered trademark of Tyco Electronics AMP.

VG-FPZ Seriesfor inverter installed home appliances' surge control[RoHS Compliant]

Caution: E represents a case.

Page 33: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1433

Casing TypeMetal cylinder

RG-208F 250 8 1500 100 1 55 -20~+50 TÜV 320RG-208F1 250 8 1500 100 1 55 -20~+50 UL, TÜV 320RG-208F2 250 8 1500 100 1 55 -20~+50 UL, TÜV 220RG-208V-A 250 8 1500 100 1 55 -20~+50 TÜV 370

EE

�RG-208F2 �RG-208F, 208F1, 208V-A

Shape and Dimensions

ModelRated

voltageAC/DC (V)

Ratedcurrent

AC/DC (A)

Leakagecurrent

250V/60Hz,(mA) max.

Certifiedstandard

Weight(g)

Self-temperature

rise(K) max.

Operatingtemperature

range(°C)

Withstandingvoltage 1 min.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.

Circuit Diagram

*Recommended torque (N.m) max. REarth terminal (M8: 4.41)

�RG-208V-A �RG-208F, 208F1, 208F2

ø502008012

M8

��

E

M8

E

A B C

4-Faston® tab terminal#250

D

Lead: UL1015AWG#16

LabelLabel

[mm]

RG-208F/F1 12 90 13 50RG-208F2 12 60 13 50

A B C D

*Faston® is a registered trademark of Tyco Electronics AMP.

Model

RG Series[RoHS Compliant]

TÜV Rheinland

Caution: E represents a screw installation portion (M8) in modelRG-208F.

Page 34: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1434

Casing TypeMetal cylinder

P Z 0

Z 0

P: Power divider Z 0 Z0 : 50�: 50�

Z 0 Z 0

Z 0

Leve

l met

er

EMI/EMCfilter

Osc

illat

or

Leve

l met

er

Osc

illat

or

EMI/EMCfilter

RG-208F, V-A, Common mode70

60

50

40

30

20

10

0

RG-208F2 Common mode

RG-208F2 Normal mode

RG-208F, V-A, Normal modeInse

rtio

n Lo

ss (

dB)

Frequency (MHz)0.01 0.02 0.05 0.1 0.2 0.5 1 52 10 20

PCommon mode

Measuring Circuit

Attenuation (Static Characteristics)

PNormal mode

Page 35: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1435

Casing TypePlastic box

MR-2021 250 2 1500 300 0.75 30 -20~+60 UL, CSA, VDE 35MR-2032 250 3 1500 300 — 30 -20~+60 UL, CSA 35MR-2043 250 4 1500 300 0.75 30 -20~+60 UL, CSA, VDE 45MR-2053 250 5 1500 300 0.75 30 -20~+60 40MR-2054 250 5 1500 300 0.75 30 -20~+60 40MR-2029 250 2 1500 300 0.5 30 -20~+60 35MR-2059 250 5 1500 300 0.5 30 -20~+60 35

IN IN

IN IN

E

E

E

�MR-2021 �MR-2032

�MR-2043, MR-2053�MR-2029, MR-2059 �MR-2054

Circuit Diagram

ModelRated

voltageAC/DC (V)

Ratedcurrent

AC/DC (A)

Leakagecurrent

250V/60Hz,(mA) max.

Certifiedstandard

Weight(g)

Self-temperature

rise(K) max.

Operatingtemperature

range(°C)

Withstandingvoltage 1 min.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.

MR Series[RoHS Compliant]

10 10

3.6�4.8

5-Faston® tab #110

(Oval hole1.2�2.0)

E

2.5

12

3350

Label

27

40

49

[mm]

Shape and Dimensions

*Faston® is a registered trademark of Tyco Electronics AMP.Caution: No E terminals on MR-2032.

Page 36: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1436

Casing TypePlastic box

P Z 0

Z 0

P: Power divider Z 0 Z 0 : 50�: 50�

Z 0 Z 0

Z 0

Leve

l met

er

EMI/EMCfilter

Osc

illat

or

Leve

l met

er

Osc

illat

or

EMI/EMCfilter

80

70

60

50

40

30

20

10

0

MR-2021Normal mode

MR-2032Normal mode

MR-2043, 2053, 2029, 2059Common mode

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)0.1 0.5 1.0 3 5 10 30 50 100

PCommon mode

Measuring Circuit

Attenuation (Static Characteristics)

PNormal mode

Page 37: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1437

Casing TypePlastic box

MA-2013 250 1 1500 300 0.75 30 -25~+55 UL, CSA, TÜV 30MA-2023 250 2 1500 300 0.75 30 -25~+55 UL, CSA, TÜV 30MA-2033 250 3 1500 300 0.75 30 -25~+55 UL, CSA, TÜV 30MA-2043 250 4 1500 300 0.75 30 -25~+55 UL, CSA, TÜV 30MA-2053 250 5 1500 300 0.75 30 -25~+55 UL, CSA, TÜV 30

P Z 0

Z 0

P: Power divider Z 0 : 50� Z 0 : 50�

Z 0 Z 0

Z 0

Leve

l met

er

EMI/EMCfilter

Osc

illat

or

Leve

l met

er

Osc

illat

or

EMI/EMCfilter

38

5 -0.7�0.7

22.5

307.

0min

.

1.0

(5.0

)

(3.0)

10.1620.32

15

20.3

2

E ELabel

(Base portion)

[mm]

IN E

100

Normal mode

90

80

70

60

50

40

30

20

10

0

Common mode

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

�MA-2043

0.1 0.5 1.0 5.0 10 20 30

Attenuation (Static Characteristics)

Shape and Dimensions Circuit Diagram

Measuring Circuit

ModelRated

voltageAC/DC (V)

Ratedcurrent

AC/DC (A)

Leakagecurrent

250V/60Hz,(mA) max.

Certifiedstandard

Weight(g)

Self-temperature

rise(K) max.

Operatingtemperature

range(°C)

Withstandingvoltage 1 min.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.

PMA Series

PCommon mode PNormal mode

MA Series[RoHS Compliant]

TÜV Rheinland

Page 38: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1438

Inlet Type

GL-2030C 250 3 1500 300 500 30 -25~+55 UL, CSA, TÜV, VDE 55GL-2060C 250 6 1500 300 500 30 -25~+55 UL, CSA, TÜV, VDE 55GL-2100C 250 10 1500 300 500 30 -25~+55 UL, CSA, TÜV 55GL-2150C 250 15 1500 300 500 30 -25~+55 UL, CSA, TÜV 55GL-2030C2 250 3 1500 300 500 30 -25~+55 UL, CSA, TÜV 55GL-2030C3 250 3 1500 300 500 30 -25~+55 UL, CSA, TÜV 55GL-2060C3 250 6 1500 300 500 30 -25~+55 UL, CSA, TÜV 55GL-2060C1 250 6 1500 300 5 30 -25~+55 UL, CSA 55GL-2080C1 250 8 1500 300 5 30 -25~+55 UL, CSA, TÜV 55GL-2080C4 250 8 1500 300 500 30 -25~+55 UL, CSA, TÜV 55GL-2030CT 250 3 1500 300 5 30 -25~+55 UL 55GL-2060C4 250 6 1500 300 500 30 -25~+55 UL, CSA, TÜV 55

P Z 0

Z 0

P : Power divider Z 0 : 50�

Z 0 : 50�

Z 0 Z 0

Z 0

Leve

l met

erEMI/EMCfilter

Osc

illat

or

Leve

l met

er

Osc

illat

or

EMI/EMCfilter

�GL-C1

�GL-CT

E E

E E

(Inlet side) (Soldered terminal side)

E E

(Inlet side) (Soldered terminal side)

(Inlet side) (Soldered terminal side)

Circuit Diagram Measuring Circuit

ModelRated

voltageAC/DC (V)

Ratedcurrent

AC/DC (A)

Leakagecurrent

250V/60Hz,(�A) max.

Certifiedstandard

Weight(g)

Self-temperature

rise(K) max.

Operatingtemperature

range(°C)

Withstandingvoltage 1 min.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.

PGL-C, C2, C3, C4 Type PCommon mode

PNormal mode

GL SeriesC Type[RoHS Compliant]

67

47.55.4

2622.5+0.5

–0.2

52 40

30.5

+0.5

–0

.3

2-3.3ø

9.5

21

3.5 2.0

4.0

Soldered terminal

EE

40 40

31.0

–0

23.0 –0 21.5–02-3.3ø2 2-M3

30.5

–0

R5 R0.5

EN60320 • 3P Inlet

29�

1.0

[mm]

Shape and Dimensions

PGL-C Type

*Recommended torque (N.m) max. RPanel installation (M3: 0.78)

Reference installation dimensions

(2) For front panel installation(1) For rear panel installation

TÜV Rheinland

Page 39: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1439

Inlet Type

GL-2030C Normal mode

100

90

80

70

60

50

40

30

20

10

GL-2030C Common mode

GL-2150C Common mode

GL-2150C Normal mode

GL-2030C3 Normal mode

GL-2030C2 Common mode

GL-2030C3 Common mode

GL-2030C2 Normal mode

GL-2080C4 Normal mode

GL-2080C1 Normal mode

GL-2080C4 Common mode

GL-2030CT Normal mode

GL-2030CT Common modeGL-2080C1 Common mode

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

�GL-2030C, 2150C

0.1 0.5 1.0 5.0 10 20 50

100

90

80

70

60

50

40

30

20

10

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

�GL-2030C2, 2030C3

0.1 0.5 1.0 5.0 10 20 50

100

90

80

70

60

50

40

30

20

10

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)

�GL-2080C1, 2080C4, 2030CT

0.1 0.5 1.0 5.0 10 20 50

Attenuation (Static Characteristics)

Page 40: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1440

Inlet Type

GL-2030F 250 3 1500 300 0.5 30 -25~+55 UL,CSA,TÜV,VDE 40GL-2060F 250 6 1500 300 0.5 30 -25~+55 UL,CSA,TÜV,VDE 40GL-2030FV 250 3 1500 300 0.5 30 -25~+55 UL,CSA,TÜV,VDE 40GL-2060FV 250 6 1500 300 0.5 30 -25~+55 UL,CSA,TÜV,VDE 40GL-2060FVP-XL 250 6 1500 300 0.1 30 -25~+55 – 90

TÜV Rheinland

ModelRated

voltageAC/DC (V)

Ratedcurrent

AC/DC (A)

Leakagecurrent

250V/60Hz,(mA) max.

Certifiedstandard

Weight(g)

Self-temperature

rise(K) max.

Operatingtemperature

range(°C)

Withstandingvoltage 1 min.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.

*FV types are also available with Faston® terminal.*Faston® is a registered trademark of Tyco Electronics AMP.

GL SeriesF, FV, FVP-XL Type[RoHS Compliant]

2-3.3ø Flat-head screw

22.5+0.5 –0.2

+0.

5 –0

.330

.552 40

40

31.0

–0

2-3.3ø

23.0–0

R5

40

30.5

–0

22.5

2-M3

R0.5

6.05246

35.5

Solderedterminal

EN60320 certified 3P inlet

21�

1.0

4.0

2.0

3.0

D 40

30.5

+0.

5 –0

.3

16+0.5 –0

22.5+0.5 –0.2

2-M3 Flat-head screw

R5

23.0–0

31.0

–0

40.0

30.0

–0

40.0

22.0–0 2-M3

R4.5

6.0B

A

12.5

C

6.5

EN60320 certified 3P inlet

26

�0.

5

�0.

5

�0.

5

14 2929�

1.0

2.6

[mm]

GL-FV 35.5 50.0 21.0 50.0GL-FVP-XL 70.0 83.3 22.0 56.0

A B C D

Shape and Dimensions

PGL-F Type PGL-FV,FVP-XL Type

*Recommended torque (N.m) max. RPanel installation (M3: 0.78)

Reference installation dimensions

Reference installation dimensions

(1) For rear panel installation

(1) For rear panel installation

※22.5 for GL-2060FVP-XL

Model

(2) For front panel installation

(2) For front panel installation

Page 41: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1441

Inlet Type

P Z 0Z 0

P: Power divider Z 0 : 50�Z 0 : 50�

Z 0 Z 0Z 0

Leve

l met

er

EMI/EMCfilter

Osc

illato

r

Leve

l met

er

Osc

illato

r

EMI/EMCfilter

(Inlet side) (Soldered terminal side) (Inlet side) (Soldered terminal side)

E EIN E EIN

GL-2030FNormal mode

100

90

80

70

60

50

40

30

20

10

0

GL-2030FVCommon mode

GL-2030F Common mode

GL-2030FV Normal mode

Inse

rtion

Los

s (d

B)

Frequency (MHz)0.1 0.2 0.5 1.0 5.0 10 20 50

�GL-2030F/2030FV100

90

80

70

60

50

40

30

20

10

0

Inse

rtion

Los

s (d

B)

Frequency (MHz)0.1 0.2 0.5 1.0 5.0 10 20 50

�GL-2060FVP-XL

Circuit Diagram

Measuring Circuit

PGL-F, FV Type PGL-FVP-XL

PCommon mode PNormal mode

Attenuation (Static Characteristics)

Page 42: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1442

Inlet Type

GL-2030H2 250 3 1500 300 0.5 30 -25~+55 TÜV 90GL-2060H2 250 6 1500 300 0.5 30 -25~+55 TÜV 90

IN

(Inlet side) (Faston® terminal side)

E E

Fuse

Fuse

ModelRated

voltageAC/DC (V)

Ratedcurrent

AC/DC (A)

Leakagecurrent

250V/60Hz,(mA) max.

Certifiedstandard

Weight(g)

Self-temperature

rise(K) max.

Operatingtemperature

range(°C)

Withstandingvoltage 1 min.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.

Circuit Diagram

PGL-H2 Type

GL SeriesH Type[RoHS Compliant]

TÜV Rheinland

40

Faston® tab terminal #2503437

2-3.5ø Flat-head screw

EN60320 certified 3P inlet

2-M3

35–0

35–0

R0.5

81.555.5

23 3450 40

5.5

1.5

[mm]

Shape and Dimensions

PGL-H2 Type (2-fuse Type)

*Recommended torque (N.m) max. RPanel installation (M3: 0.50)

*Faston® is a registered trademark of Tyco Electronics AMP.

Reference installation dimensionsfor front panel installation

Page 43: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1443

Inlet Type

P Z 0

Z 0

P: Power divider Z 0 : 50�Z 0 : 50�

Z 0 Z 0

Z 0

Leve

l met

er

EMI/EMCfilter

Osc

illat

or

Leve

l met

er

Osc

illat

or

EMI/EMCfilter

GL-2030H2 Common mode

80

70

60

50

40

30

20

10

0

GL-2030H2 Normal mode

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)0.1 0.2 0.5 1.0 5 10 20 50 100

Measuring Circuit

PCommon mode PNormal mode

Attenuation (Static Characteristics)

Page 44: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1444

Inlet Type

GL-2030M 250 3 1500 300 0.5 30 -25~+55 UL, CSA, TÜV 200GL-2060M 250 6 1500 300 0.5 30 -25~+55 UL, CSA, TÜV 205GL-2100M 250 10 1500 300 0.5 30 -25~+55 UL, CSA, TÜV 210

GL-2030M Normal mode

100

90

80

70

60

50

40

30

20

10

0

GL-2030M Common mode

Inse

rtio

n Lo

ss (

dB)

Frequency (MHz)0.1 0.2 0.5 1.0 5.0 10 20 30

ModelRated

voltageAC/DC (V)

Ratedcurrent

AC/DC (A)

Leakagecurrent

250V/60Hz,(mA) max.

Certifiedstandard

Weight(g)

Self-temperature

rise(K) max.

Operatingtemperature

range(°C)

Withstandingvoltage 1 min.,line to ground

AC (V)

Insulation resistance500VDC 1 min.,line to ground

(M�) min.

P Z 0

Z 0

P: Power divider Z 0 : 50�Z 0 : 50�

Z 0 Z 0

Z 0

Leve

l met

er

EMI/EMCfilter

Osc

illat

or

Leve

l met

er

Osc

illat

or

EMI/EMCfilter

Measuring Circuit

PCommon mode PNormal mode

E

(Inlet side)

IN E

(Faston® terminal side)

Circuit Diagram

PGL-M Type

2-4.3ø

3816

56 4030

.5+0

.5

–0.3

22.5 +0.5 –0.2

EN60320 certified 3P inlet

Faston® tab terminal#250

33

10

25

8263.5 23–0

4031

R5

2-M3

–0

[mm]

Shape and Dimensions

PGL-M Type

*Recommended torque (N.m) max. RPanel installation (M3: 0.735)

Reference installation dimensions forpanel rear installation

*Faston® is a registered trademark of Tyco Electronics AMP.

Attenuation (Static Characteristics)

GL SeriesM Type[RoHS Compliant]

TÜV Rheinland

Page 45: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Noise Filters VOL.1445

TÜV Rheinland Japan Ltd. Certification Numbers

Noise Filters

Page Item File No.

16LF Series Three-Phase

Terminal Block Type

LF-3200No.R50014468

LF-3300

LF-3400 No.R50014560

LF-3500 No.R5008093

LF-3600 No.R50014465

20LH Series Three-Phase

Terminal Block / High Attenuation Type

LH-3304

No.R50133298

LH-3404

LH-3604

LH-3804

LH-31204

LH-31504

21 HFP SeriesHFP-2153 No.R50014217

HFP-2303 No.R50013926

23GT Series Screw

Terminal

GT-220U No.R9651191

GT-205U

No.R50015833

GT-210U

25GT Series Faston®

Terminal

GT-20301

GT-20601

GT-21001

GT-20302

GT-205J

No.R50014761GT-210J

GT-215J

27 GT Series for VCCIGT-21001V No.R2-50004761

GT-22001V No.R50007113

29 VU Series VU-220F No.R50015793

31 VC Series VC-215F3V No.R50013342

33 RG Series

RG-208FNo.R2-50006637

RG-208F1

RG-208F2 No.R50013629

RG-208V-A No.R2-50006637

Page Item File No.

37 MA Series

MA-2013

No.R50015843

MA-2023

MA-2033

MA-2043

MA-2053

38 GL Series C Type

GL-2030CNo.R50013357

GL-2060C

GL-2100C No.R50014260

GL-2150C No.R50014261

GL-2030C2

No.R50013357GL-2030C3

GL-2060C3

GL-2080C1No.R50014166

GL-2080C4

GL-2060C4 No.R50013357

40 GL Series F Type

GL-2030FNo.R50013360

GL-2060F

GL-2030FVNo.R50015850

GL-2060FV

42 GL Series H TypeGL-2030H2

No.R50015796GL-2060H2

44 GL Series M Type

GL-2030M

No.R50013384GL-2060M

GL-2100M

Page 46: Phone: +82-2-551-3651 Fax: +82-2-551-3650 TOKIN ... - KEMET · Features Applications Model *1 Rated voltage AC/DC (V) Rated current AC/DC (A) Withstandin g voltage 2 sec., line to

●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact TOKIN for updated product data.●Please request for a specification sheet for detailed product data prior to the purchase.●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.

9615NFSVOL14E1704E1

Precautions

The names of the products and the specifications in this

catalog are subject to change without notice for the sake

of improvement. The manufacturer also reserves the right

to discontinue any of these products. At the time of

delivery, please ask for specifications sheets to check the

contents in order to use the products properly and safely.

Descriptions in this catalog regarding product

characteristics and quality are based solely on discrete

components. When using these components, be sure to

check the specifications with the component in question

mounted on the products.

The manufacturer,s warranty will not cover any

disadvantage or damage caused by improper use of the

products that deviates from the characteristics,

specifications, or conditions for use described in this

catalog.

The products in this catalog are intended for use in

ordinary electronic products. If any of these products are

to be used in special applications requiring extremely high

reliability, such as in aviation equipment and nuclear

power controllers where product defects might pose a

safety risk, please consult your TOKIN sales

representatives.

Though the manufacturer has taken all possible

precautions to ensure the quality and reliability of its

products, improper use of products may result in bodily

injury, fire, or similar accident. If you have any questions

regarding the use of the products in question, please

consult your TOKIN sales representatives.

Please be advised that the manufacturer accepts no

responsibility for any infraction by users of the

manufacturer,s products on third party patents or

industrial copyrights. The manufacturer is responsible only

when such infractions are attributable to the structural

design of the product and its manufacturing process.

Export Control

For customers outside Japan

TOKIN products should not be used or sold for use in the

development, production, stockpiling or utilization of any

conventional weapons or mass-destructive

weapons(nuclear weapons, chemical or biological

weapons, or missiles), or any other weapons.

For customers in Japan

For products which are controlled items subject to

the “Foreign Exchange and Foreign Trade Law” of

Japan, the export license specified by the law is required

for export.

This catalog is current as of April 2017.