philips plasma panel repair training 2006
TRANSCRIPT
![Page 1: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/1.jpg)
1
1
PHILIPS TECHNICAL TRAINING
PLASMA PANEL REPAIR
![Page 2: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/2.jpg)
2
![Page 3: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/3.jpg)
3
ADDRESS ELECTRODES
BARRIER RIBS
![Page 4: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/4.jpg)
4
DISPLAY ELECTRODES
![Page 5: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/5.jpg)
5
FRONT GLASS PLATE
![Page 6: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/6.jpg)
6
NEON XENON GAS
![Page 7: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/7.jpg)
7
• CHARGE / DISCHARGE CYCLE– Uses Neon Xenon gases– A voltage is applied between the Address
Electrodes and display electrodes to stimulateultraviolet radiation UV
– UV stimulation causes color phosphors to glow– These form picture elements
7
![Page 8: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/8.jpg)
8
PANEL Module IntroductionPANEL Module Introduction
4. BLOCK DIAGRAM
8
![Page 9: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/9.jpg)
9
![Page 10: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/10.jpg)
10
![Page 11: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/11.jpg)
11
![Page 12: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/12.jpg)
12
SDI BUILT PANELS IN PHILIPS SETS ARE THE ONLY PANELS FEATURED IN THIS TRAINING
12
![Page 13: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/13.jpg)
13
13
![Page 14: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/14.jpg)
14
14
![Page 15: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/15.jpg)
15
15
![Page 16: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/16.jpg)
16
16
![Page 17: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/17.jpg)
17
![Page 18: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/18.jpg)
18
PDP model name, with or without PSU
10 1 3 03 26 0577
Type: 02 - 48
Line No: 1 -9
Year
Month: 01 - 12
Date: 01 - 31
Serial No: 0001 - 9999
Serial No
101303260577
Power supply settings
18
PDP LABEL
![Page 19: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/19.jpg)
19
![Page 20: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/20.jpg)
20
![Page 21: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/21.jpg)
21
![Page 22: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/22.jpg)
22
![Page 23: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/23.jpg)
23
42 INCH V4 PANEL USED IN BP SET WITH SSB REMOVED
Y DRIVER POWER SUPPLY
X-DRIVERLOGIC BOARD
E BOARDSY BUFFERS
![Page 24: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/24.jpg)
24
50HDV3
![Page 25: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/25.jpg)
25
50HDV4
![Page 26: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/26.jpg)
26
Panel Location FM242 / FTP1.1 YD06 / YB04 Panels
42 INCH SDV2 MODULE LAYOUT
![Page 27: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/27.jpg)
27
Panel module label Voltage labelSerial No.
1 Logic Main2 X-main3 Y-main
8 Logic-buffer G9 FFC Logic + Y-main10 FFC Logic + X-main
4 Y-buffer upper 5 Y-buffer low6 Logic-buffer E7 Logic-buffer F
11 Logic + Logic buffer12 Logic + Logic buffer13 Logic + Logic buffer
1
23
4
5
6 7 8
9 10
11 12 13
PSUSUB-PSU
42 INCH SDV3 MODULE LAYOUT
![Page 28: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/28.jpg)
28
SubL
PSU
Y-main BoardX-main board
Logic-buffer (E) Logic-buffer (F) Logic-buffer (G
Logic-buffer (H) Logic-buffer (I) Logic-buffer (J)Y
-buf
fer
upY
-buf
fer
dow
n
Logic-main board
SUB PSU
SubR
TCP´s
50 INCH HD V3 MODULE LAYOUT
![Page 29: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/29.jpg)
29
PICTURE OF 50 HD V3
29
![Page 30: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/30.jpg)
30
■.SMPS(Switching Mode Power Supply) : Supplies voltage and current to operate assemblies mounted to each board and Panel.
■.X Main Board : According to the timing provided from Logic board, switches FETs and generates driving waveform which is provided to X electrode of Panel through Connector.
■.Y Main Board :According to the timing provided from Logic board, switches FETs and generate driving waveform which is provided to Y electrode of Panel sequentially through Scan Driver IC of Scan Buffer.
■.Logic Main Board : Processes image signal and generates Address driving output signal & XY driving signal
■.Logic Buffer Board(E,F,G) (+ Logic Buffer H, I, J if HD Display)Transfers data signal and control signal to COF.
■.Scan Buffer(Upper,Lower) : A board allows scan waveform to Y terminal, which is consisted of Upper Board and Lower Board.
(Y-Buffer(Upper,Lower) )■.AC Noise Filter : Blocks noise and spikes and noise on the AC line.
■.COF(Chip on Flexible) or (TCP Tape Carrier Package) : It allows Va pulse to address electrode within address period and forms address discharge according to the electric potential difference between Va pulse and the Scan pulse allowed to Y electrode. It is manufactured in COF form and one COF is consisted of four DATA Drive IC .
30
![Page 31: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/31.jpg)
31
TCP DRIVER
31
![Page 32: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/32.jpg)
32
32
V2
![Page 33: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/33.jpg)
33
PANEL DEFECTS
33
![Page 34: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/34.jpg)
34
Defect : panel damage■ Symptom : Panel crack or break. No image appears in some cause depending on the damaged parts and damage level.
Defect: Exhaust pipe damage
■ Symptom. : Crack in break if exhaust pipe an image is partially lacking or the panel noise occurs depending on the damaged parts and after a certain time.
Or very loud noise from the panel.
■ Cause① Manufacturing : Flatness/palette pin interruption② Operation : overload of panel corner / careless handling③ Panel : Flatness / assembly error ■ Cause : Carelessly panel handling
34
![Page 35: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/35.jpg)
35
Check exhaust Tip for Cracks with naked eyes to check vacuum state.
If there is problem then replace the module by new one .
⇒ In case of vacuum breakdown, module makes a shaking noise because of inside gas ventilation.
(there may be a small crack which could not see with naked eyes. And this noise is different from Capacitor noise. )
1.2 Exhaust tip Crack
CRACKEDNORMAL
35
![Page 36: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/36.jpg)
36
Logic Main, Logic Buffer, FFC, TCP
Some vertical lines appear to be linked on Display
Address Short
Logic Main. Logic Buffer, FFC, TCP
Some vertical lines don´t exist on the Display.
Address Open
Scan Buffer, FPC of X / YSome horizontal lines appear to be linked on Display.
Sustain Short
Scan Buffer, FPC of X / YSome horizontal lines don´t exist on the Display
Sustain open
Y-Main, X-Main, Logic Main
Abnormal Image (not open or short) is on Display
Abnormal Display
Y-Main, X-Main, Logic Main, connections
Operating voltages exist, but no Display
No Display
PSUOperating Voltages don´t existNo voltage output
Related BoardDescriptionSymptom
36
![Page 37: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/37.jpg)
37
Vertical stripe = Address open Vertical stripe = Address Short
Defect: Address output error
37
![Page 38: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/38.jpg)
38
Defect horizontal stripe: Sustain Open Defect horizontal stripe: Sustain Short
Symptom : One or more line do not light up in Sustain direction
Symptom : Combined or adjacent lines are short in sustain direction. The line appear brighter than other at Ramp gradation pattern or low gradation patter
38
![Page 39: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/39.jpg)
39
Address and Sustain OpenAddress Block and Line Open
Defect: Dielectric material layer damage
■ Symptom:
Phosphor damage caused by the damage of address bus dielectric layer appears in the panel discharge/non discharge area. sustain also open/short occurs by the damage of address sustain printout
Cause : layer uneven / abnormal voltage / foreign material repair failed.
39
![Page 40: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/40.jpg)
40
Defect: Full White low discharge . Defect: Weak discharge
Symptom : Low discharge caused by unstable cells occurring at full white pattern if high (60 degree) or normal temperature.
Symptom : Normal discharge but cells appear darker due to weak light emission occurring mainly at low (5 degree) Full White/ Red/ Green/ Blue pattern or gradation pattern
40
![Page 41: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/41.jpg)
41
DEFECTIVE TCP
![Page 42: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/42.jpg)
42
42
DISASSEMBLY TIPS
![Page 43: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/43.jpg)
43
CONNECTOR BETWEEN YUPPER AND LOWER ON42HDV4 PANEL
42HDV4 PANEL
43
![Page 44: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/44.jpg)
44
Removal
Pull out the FPC from connector by holding the lead of the FPC with hands
Assembling
Push the lead of FPC with same strength until to be connected completely.
Be careful do not damage the connector pin during connecting
DISASSEMBLY OF THE Y BUFFER
![Page 45: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/45.jpg)
45
Disassembling
Pull out the connector clamp Pull Flat cable out press down lightly Move away from connector
Assembling
Put the Flat cable into the connector press down lightly until locking click
45
X BOARD CONNECTION
![Page 46: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/46.jpg)
46
46
![Page 47: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/47.jpg)
47
PRESS ON THE RIBBON CONNECTOR TO ENSURETHAT IT IS PROPERLY SEATED
![Page 48: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/48.jpg)
48
1 2 3 4 5 6 7
1) Remove the screws in order of 2-3-5-6-7-1-4 from heat sink and then get rid of heat sink.2) Remove the TPC, FFC and power cable from the connectors.3) Remove all of the screws from defected board.4) Remove the defected board.5) Replace the new board and then screw tightly.6) Get rid of the foreign material from the connector.7) Connect the TCP,FFC and power cable to the connector.8) Reassemble the TCP heat sink.9) Screw in order of 4-1-7-6-5-3-2. If you screw too tightly, it is possible to get damage on the Driver IC of TCP.
Be care when using electric Screwdriver!
48
![Page 49: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/49.jpg)
49
42HDV3 SCREW REMOVAL AND REPLACEMENT
![Page 50: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/50.jpg)
50
Disassembling of TCP
Assembling of TCP
Open the clamp carefully Lift the TCP out from connector
Put the TCP into the connector carefully and check alignment Close the clamp completely, until locking click
50
![Page 51: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/51.jpg)
51
TCP DRIVER
51
![Page 52: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/52.jpg)
52
TROUBLESHOOTING
52
FIRST DETERMINE IF THE PROBLEM IS THETHE SMALL SIGNAL BOARD OR THE PDP
PANEL PROBLEM
OPERATE PANEL IN INTERNAL (STAND ALONE)
CHECK POWER SUPPLY VOLTAGES
CHECK Y-BUFFER AND X-BOARD OUTPUTS
![Page 53: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/53.jpg)
53
Trouble Shooting on No Display and Abnormal Display 42”SDV2
53
SCOPE WITH DUAL TIME BASE DELAYED SWEEP REQUIREDHIGH FREQUENCY REJECTION SWITCH MAY BE NEEDED TO
TRIGGER ON THE V-SYNC
![Page 54: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/54.jpg)
54
V2 PANEL IN SERVICE POSITION WITH SSB/SCAVIO REMOVED
54
![Page 55: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/55.jpg)
55
SHORT PINS 1 AND 2 OF CN8002SHORT PIN 11(STANDBY) TO
GROUND TO SWITCH THE SET ONOR
USE TEST JIG 3122 785 90760
55
V2
![Page 56: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/56.jpg)
56
SHORT J8002 TO SWITCHTHE POWER SUPPLY VA
AND VS SUPPLIES.
56
V2
![Page 57: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/57.jpg)
57
TP 13 V-SYNC
57
This test point location may change with a different logic board.V-SYNC IS NECESSARY TO TRIGGER THE SCOPE
THE SCOPE MAY NOT TRIGGER WITHOUT AHF REJECTION SWITCH
V2
![Page 58: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/58.jpg)
58
V3
58
WITHOUT ADAPTERCONNECT PIN 9 CN9005 TO PIN10 CN9004CONNECT PIN 4 TO PIN 7 OF CN9005
![Page 59: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/59.jpg)
59
1. Check Input Voltage Range of the defectoccurrence area is between 100V AC ~ 240V AC
2. Insert Jumper at J8003, J8004 BJ89023. Insert Power (AC) at CN80014. Check if the LED turn on or not as sequence.
(LED8001→LED8002→BD8903)5. If all the LEDs (LED8001, LED8002, BD8903)
are ON, the PSU is not defective. 6. If one of the LEDs (LED8001, LED8002,
BD8903) is OFF, the PSU is defective.
CN8001
J8003J8004
Right PositionBJ8902
LED8002
BD8903
LED8001
Protection & LED indication for Fault Finding
CHECKING THE V4 POWER SUPPLY UNLOADED
![Page 60: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/60.jpg)
60
BJ8902
BJ8901Alarm led
![Page 61: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/61.jpg)
61
PSU troubleshoot
• As verification, this is possible to disable protection: by puting jumper BJ8901 (on alarm board)– This disables the protection circuits so that the
power supply operation can be checked
• Caution: in this case there is a risk of more damages…
61
V4
![Page 62: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/62.jpg)
62
BJ8902
SWITCHES ON THE VS SUPPLY WHEN THE LOGIC BOARD ISNOT CONNECTED
![Page 63: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/63.jpg)
63
Error codes can be read by counting the blinking rate of BD8903 LED located on the Alarm board.
BD8903
63
V4
![Page 64: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/64.jpg)
64
13 TIMESD5VL OVP, UVP
4 TIMESD3V3 OVP, UVP
3 TIMESVSCAN OVP, UVP
2 TIMES12V OVP, UVP
11 TIMES5V2 OVP or Active DC_PROT
10 TIMESPFC_OK UVP (>330V)
9 TIMESOver Temperature (<105℃)
8 TIMESVE OVP, UVP
7 TIMESVSET OVP, UVP
6 TIMESVG OVP, UVP
5 TIMESVS OVP, UVP
1 TIMEVA OVP, UVP
LED SignatureDetect Error condition
64
V4
![Page 65: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/65.jpg)
65
DC VOLTAGES AND CURRENTS 42SDV4 ONLY
65
V4
![Page 66: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/66.jpg)
66
PLACE JUMPER HERE ON THE LOGIC BOARD TO TURN THE SCREEN WHITE
V4
66
![Page 67: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/67.jpg)
67
67
TEST WAVEFORMS
![Page 68: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/68.jpg)
68
V Sync on Channel A CN201 2ms/Div/2V5
6 Y Output on Out 4 100V/Div
X-Output TP Out7
By use of Delayed Time Base
68
SCOPE SETTINGS 42SDV2
![Page 69: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/69.jpg)
69
UPPER PULSE IS SYNC
LOWER IS OUTPUT OF YBUFFER
69
42SDV2
![Page 70: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/70.jpg)
70
Y-BUFFER
X-BOARD
42HDV4 – Y BUFFER USING x100 PROBE
![Page 71: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/71.jpg)
71
71
ALIGNMENTS
![Page 72: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/72.jpg)
72
72
NO ALIGNMENTS ARE NECESSARY WHEN REPLACINGTHE FOLLOWING PANELS
X-BOARD
Y-BUFFER BOARDS
LOGIC BOARD
LOGIC DRIVER BOARDS (E)
![Page 73: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/73.jpg)
73
73
POWER SUPPLY
THE POWER SUPPLY SHOULD BE CHECKED ANDADJUSTED IF NECESSARY ACCORDING TO THE CHART LOCATED ON THE PLASMA PANEL
EACH POWER SUPPLY IS SET TO OPTIMIZE EACH PANEL
![Page 74: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/74.jpg)
74
VOLTAGE CHARTLOCATED IN THE UPPER RIGHT HAND CORNER
VIEW FROM THE BACK OF THE SETSOME PANELS HAVE A DIFFERENT LOCATION
![Page 75: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/75.jpg)
75
POWER BOARD ALIGNMENTS 42SDV4
SUB POWER BOARDD3V3 VR9005 CHECK CHARTD6V VR9004 CHECK CHART
MAIN POWER BOARDVSCAN VR8005 CHECK CHARTVSET VR8003 CHECK CHARTD3V3 VR8006 CHECK CHARTVSB VR8002 CHECK CHARTVE VR8008 CHECK CHARTVS VR8004 CHECK CHARTPFC VR8001 DO NOT ADJUSTVA VR8007 CHECK CHART
75
![Page 76: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/76.jpg)
76
After changing PSU, Check and Adjust the
voltage of 8 points.
If turn right, voltage up
If turn left, voltage down
1.VS
2.VA
3.VSET
4.VSCAN
5.VE
6.D3V3
7.D5V
8.12VL
VSCAN
VE
Voltage
Up
VSET
VS
VA
12V
D5VL D3V3
Voltage
Down
76
V4
![Page 77: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/77.jpg)
77
CONDITION CAUSED BY MISADJUSTED POWER SUPPLY
![Page 78: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/78.jpg)
78
78
Y-DRIVER BOARD
THE Y-DRIVER ADJUSTMENTS SHOULD BE CHECKEDAND ADJUSTED IF NECESSARY TO OPTIMIZE PICTUREPERFORMANCE
A DUAL TIME BASE OSCILLOSCOPE IS REQUIRED TOMAKE ACCURATE ADJUSTMENTS
TO OBTAIN A STABLE WAVEFORM, SYNC THE SCOPE TO THE V-SYNC ON THE LOGIC PANEL
THE Y-DRIVER MAY HAVE CHANGED IN PRODUCTIONMATCH THE PICTURE OF YOURS WITH THE ONE INTHE SERVICE MANUAL TO VERIFY THAT THECORRECT ADJUSTMENTS ARE BEING PERFORMED
![Page 79: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/79.jpg)
79
HIGHLIGHT THE WAVEFORM TO EXPAND
![Page 80: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/80.jpg)
80
80
THE PREVIOUS EXAMPLE IS A WAVEFORM VIEWED WITH A TEKTRONIX
OSCILLOSCOPE
EACH OSCILLOSCOPE WORKS A LITTLE DIFFERENT
![Page 81: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/81.jpg)
81
1) Make Full White on Screen.
2) Observe waveform using Oscilloscope.
① check OUT4 TP in Y-buffer(upper).
Observe the waveform of the third waveform of 1TV-Field.
② Adjust the division of oscilloscope like the left picture
③ Adjust the period of Vset as 10µS,
that of -Vsc(1) as 20µs,
that of -Vsc(2) as 5µs,
turning VR (Variable Resistor)
(only,when you adjust each period of -Vsc(1) & -Vsc(2)
adjust Vertical Division of oscilloscope as '2V or 5V')
④ VR for Vset : VR5003 (Y_main)
VR for -Vsc(1) : VR5001 (Y_main)
VR for -Vsc(2) : VR5002 (Y_main)
81
42SDV2
![Page 82: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/82.jpg)
82
82
![Page 83: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/83.jpg)
83
VR5002 Raising Ramp Flat Time
VR5003Falling Ramp Flat Time
VR5004VSCH
V Scan High
VR50013th Falling Ramp Flat Time
Y test pointV-Sync test point
83
![Page 84: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/84.jpg)
84
1. VR5004 Adjustment : Vsch TP => 40volt
2. VR5002 Adjustment : Rising Ramp flat time: Typ. 10usec
4. VR5001 Adjustment : 3th SF Falling Ramp flat time => Typ. 30usec
3. VR5003 Adjustment : Falling Ramp flat time => Typ. 30usecTP:Vsch
VR5004
84
42SDV3
![Page 85: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/85.jpg)
85
10 ㎲VR5001Falling_Ramp_3rd
20 ㎲VR5003Falling_Ramp_1st
10 ㎲VR5002Rising_Ramp42HDV3
10 ㎲ (10 ~ 15)Falling_Ramp_3rd
10 ㎲ (10 ~ 15)Falling_Ramp_1st
30 ㎲ (30 ~ 40)Rising_Ramp37SDV4
30 ㎲VR5001Falling_Ramp_3rd
30 ㎲VR5003Falling_Ramp_1st
10 ㎲VR5002Rising_Ramp42SDV3
20 ㎲Falling_Ramp_3rd
35 ㎲Falling_Ramp_1st
50 ㎲Rising_Ramp50HDV3
DefaultAdjusting Location NoWave Form
85
![Page 86: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/86.jpg)
86
PLACE JUMPER HERE ON THE LOGIC BOARD TO TURN THE SCREEN WHITE
VSYNCOR VTOGG
GND
42HDV4
![Page 87: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/87.jpg)
87
Y DRIVE TEST POINT42HDV4
![Page 88: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/88.jpg)
88
42HDV4
![Page 89: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/89.jpg)
89
![Page 90: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/90.jpg)
90
15V
RISING ADJX100 PROBE USED
![Page 91: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/91.jpg)
91
![Page 92: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/92.jpg)
92
50uS
100V
VR5002 FALLING ADJ
![Page 93: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/93.jpg)
93
REFER TO THE PDP REPAIR MANUAL FOR ALL ADJUSTMENTS
93
![Page 94: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/94.jpg)
94
WHEN REPLACING THE SSB, BE SURE TOSET THE SCREEN NUMBER AND TYPE
THESE SHOULD BE LISTED IN THE SCREENSERVICE MANUAL
![Page 95: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/95.jpg)
95
95
SCREEN DIVERSITY
WHEN CHANGING THE SSB, IT IS IMPORTANT TO PROGRAM THE SCREEN DIVERSITY CODE AS SHOWNON THE OPTION CODE LABEL.
IF THE WRONG CODE HAS BEEN ENTERED CAUSINGTHE SCREEN TO BE BLANK, THE DIVERSITY CODECAN BE RESET BY ENTERING 0 6 2 5 9 8 MENU FOLLOWEDBY THE CORRECT CODE.
![Page 96: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/96.jpg)
96
![Page 97: Philips Plasma Panel Repair Training 2006](https://reader034.vdocuments.site/reader034/viewer/2022042512/552121494a79597d718b499c/html5/thumbnails/97.jpg)
97