philips ledtube t8 instantfit ultra high output vendor/led lamps... · the philips led t8...

8
Philips LEDtube T8 InstantFit Ultra High Output

Upload: dangdung

Post on 23-Feb-2018

216 views

Category:

Documents


1 download

TRANSCRIPT

Philips LEDtube T8 InstantFitUltra High Output

The Philips LED T8 InstantFit lamp is a technology breakthrough out of our LEDtube portfolio. This product is compatible with instant start ballasts and is the easiest way to replace fluorescent tubes with LED tubes. The InstantFit lamp is a true plug-and-play LED solution that realizes an energy savings.

Driver• Compatible with most instant-start ballasts

• Designed and approved to UL, CSA and FCC requirements

Optics• Advanced optical system coated with high reflectivity material

Dimension• Complies with IEC and ANSI standards

Thermal• Enhanced thermal management features

LED• Latest innovation in LED chip design

3

Compatibility• Innovative driver design that enables a “plug-and-play” LED

solution to replace existing fluorescent lamps• Quick and easy installation

Reliability• Reliable operation between -20 oC and 45 oC ambient

temperature• Tested to B50 L70 requirement. InstantFit lamps are rated for

70,000 hours. • 50,000 switching cycles

User Comfort• CRI 82• Advanced optical design ensures a uniform light output and

superior optical efficiency

Energy Savings• Energy savings of up to 35%*

Safety• Over voltage and over temperature protection.• Complies with UL and CSA safety requirements.• Shatterproof polycarbonate (PC) material.

Environment• No Mercury.• Low Carbon Footprint.

Product Features

* Based on comparison between 2 x 16.5W LED InstantFit T8 (2-lamp

system power = 40W) vs. 2 x 32W T8 TL System (2-lamp system power

=58W), both lighting systems including lamps and reference instant start

ballasts with BF 0.88

Application

Hospitals Offices

Parking Lots Warehouses Public Areas

4

Spectral Power Distribution

Retail Industry Schools

Photometric Diagrams

5

Lifetime and Lumen Maintenance

Philips LED T8 InstantFit Lamp has a lifetime of

70,000 hours for low and normal ballast factors

and 50,000 for high ballast factors. This is defined

as the number of hours when 50% of a large

group of identical lamps drops below 70% of its

initial lumens.

1 x TLED 16.5W 3500K 160D 1 x 2400 lm

1 x TLEDtube 16.5W 5000K 160D 1 x 2500 lm

1 x TLEDtube 16.5W 4000K 160D 1 x 2500 lm

100%

95%

90%

85%

80%

75%

70%

Lum

en M

ainte

nanc

e

Hours

0 2000010000 30000 40000 50000 60000 70000

Ballast factor<=0.88

Ballast factor>0.88

6

Operating temperature T operating min -20°C max +55°C

Storage temperature T case min -40°C max +65°C

Maximum surface temperature for rated lifetime of tube at Tamb.=25°C T case +45°C

Temperature

Dimensions (mm)Product A1

1200mm 1198.1 1204.1 1212.3 27.8

DA2 A3

A1A2A3

D

The product complies with UL, CSA, DLC, NSF and RoHS.

Approbation & Certificates

Dimension: mm100%

99%

98%

97%

96%

95%

94%

93%

92%

Lum

en (

%)

T c (oC)

43 48 53 58 63

Philips Logo side

TC position

SECTION D - D

7

Technical specification

Installation Guide

ON

6

The Philips LED T8 InstantFit lamp automatically adjust its light output that corresponds to the ballast factor that it is connected to Installation Guide.

Application Notes

• Product is not dimmable.• Suitable for dry & damp locations.• Operating fixture ambient is -20°C and +55°C.• Always switch off power to the luminaire before commencing work.• Compatible only with instant-start ballasts. Please refer to www.philips.com/instantfit for the latest ballast compatibility guide.• Use shunted sockets with instant-start ballast & unshunted sockets with programmed-start ballasts.• Ensure that the lamp holders are free from any debris and/or containments and that the Philips InstantFit T8 LED Lamp pins are firmly seated in their lamp holders. For additional installation tips, please refer to www.philips.com/instantfit.• Philips LED T8 InstantFit lamps are not compatible with luminaires that use a remote starter.• Philips LED T8 InstantFit lamps are intended to retrofit, UL Listed surface mount, or type IC or non-IC recessed mount fluorescent luminaries with or without diffuser that use straight tubular lamps.

Please refer to www.philips.com/tled for the latest ballast compatibility guide.

* Tested to B50 L70 requirement.

2 3

OFF

1

4 5

Product Description Bare Lamp Watts Average System Watts Inital Lumens Life time * Life time Base Length Bulb Product (W) (W) Type Number Low Normal High Low Normal High Low Normal High Ballast Ballast Ballast Ballast Ballast Ballast Ballast Ballast Ballast Ballast Ballast factor factor Factor Factor Factor Factor Factor Factor Factor Factor Factor <=0.88 >0.88 (0.78) (0.88) (1.18) (0.78) (0.88) (1.18) (0.78) (0.88) (1.18) (hrs) (hrs) (In.)

16.5T8 LED/48-3500 IF 10/1 UHO 14.5 16.5 21.0 18 20 27 2200 2400 2950 70,000 50,000 G13 48 T8 463133

16.5T8 LED/48-4000 IF 10/1 UHO 14.5 16.5 21.0 18 20 27 2250 2500 3050 70,000 50,000 G13 48 T8 463141

16.5T8 LED/48-5000 IF 10/1 UHO 14.5 16.5 21.0 18 20 27 2250 2500 3050 70,000 50,000 G13 48 T8 463158

• Pre-Heat Luminaire and Caution stating “CAUTION – RISK OF FIRE. DO NOT INSTALL IN A PRE-HEAT LUMINIRE”.Some older fluorescent luminaires contain a starter that heats the filaments for several seconds before starting the lamp. These luminaires are called Pre-Heat luminaires. They employ a starter which is typically housed in a small cylindrical metal can. The risk of fire hazard could possibly be due to zero impedance across the ballast when the filament is not present and the pins are shorted. This can cause higher currents through the circuit than when starting a fluorescent lamp, causing the ballast to overheat. The pins of the InstantFit TLED are not interenally shorted and therefore there is no current going through the circuit. InstantFit TLEDs have been tested to ensure there is no hazard when accidently installed in a pre-heat luminaire, however Philips does not guarantee proper operation.

• Philips LED T8 InstantFit lamps can be used with emergency ballasts that are approved by the emergency ballast manufacturer and Philips. Please refer to www.philips.com/tled for an approved list of emergency ballast that are compatible with the Philips LED T8 InstantFit lamps.

© 2016 Philips LightingAll rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent or other industrial or intellectual property rights.

01/2016www.philips.com

OEM Guideline

Failure rate vs. Lifetime @ Ta 25 OC Lumen Maintenance vs. Lifetime

Failure Rate vs. Lifetime vs. Tcase

Lifetime vs. Tcase

100%90%80%70%60%50%40%30%20%10%

00 70000600002000010000 40000 5000030000

Cum

ulat

e Fa

ilure

Rat

e

Hours

100%

95%

90%

85%

80%

75%

70%

Lum

en M

ainte

nanc

e

Hours

0 2000010000 30000 40000 50000 60000 70000

80%

70%

60%

50%

40%

30%

20%

10%

00 2000010000 30000 5000040000 7000060000

TC=45

TC=55

TC=65

Tota

l Fail

ure

Rate

Hours35 45 55 65

70000

60000

50000

40000

30000

20000

10000

0

F10L70

F50L70

Life

time

(hou

rs)

TC (oC)

Ballast factor<=0.88

Ballast factor>0.88

Ballast factor<=0.88