pf0-01 existing conditions and demolition plan · scale: 1/16" = 1'-0" 2 4 8 true...

6
1158.5 1158.5 1159.0 1159.0 1158.6 1158.6 1158.7 1158.7 1158.8 1158.8 1158.9 1158.9 1159.1 1159.1 1159.2 PROJECT NO. ISSUED BY: ISSUED DATE: TITLE: DISCIPLINE - CATEGORY - SUB CATEGORY - SHEET REVISIONS Playing Field Design 4800 Main Street, Suite 300 Kansas City, Missouri, 64112 816.221.1500 TM Cardinal Engineering 525 Central Park Drive, Suite 500 Oklahoma City, Oklahoma 73105 405-842-1066 Civil Engineer JACOBS TRACK AND FIELD FACILITY INFIELD Renovation Norman, Oklahoma FOR REFERENCE ONLY - NOT FOR CONSTRUCTION CONSTRUCTION DOCUMENTS APRIL 17, 2020 19.4930 REV # DATE DESCRIPTION 04.17.2020 Copyright 2020 © 4/17/2020 9:30 PM LEGEND PLAYING FIELD DEMOLITION PLAN 1/16" = 1'-0" 0 32 16 SCALE: 1/16" = 1'-0" 24 8 TRUE NORTH EXISTING CONDITIONS AND DEMOLITION PLAN PF0-01 EXISTING SHOT-PUT PAD TO REMAIN UNDISTURBED EXISTING SHOT-PUT PAD TO REMAIN UNDISTURBED EXISTING SHOT-PUT PAD TO REMAIN UNDISTURBED EXISTING RUNNING TRACK TO REMAIN UNDISTURBED EXISTING RUNNING TRACK TO REMAIN UNDISTURBED EXISTING RUNNING TRACK TO REMAIN UNDISTURBED EXISTING RUNNING TRACK TO REMAIN UNDISTURBED EXISTING RUNNING TRACK TO REMAIN UNDISTURBED EXISTING RUNNING TRACK TO REMAIN UNDISTURBED EXCAVATE TO DESIGNED SUBGRADE AND REMOVE OFF-SITE, ALL PLAYING FIELD MATERIALS INCLUDING, BUT NOT LIMITED TO: 1. SOD 2. ROOTZONE 3. DRAINAGE GRAVEL 4. IRRIGATION EQUIPMENT AND PIPING APPROXIMATE LOCATION OF EXISTING VERTICALLY PLACED HYDRAWAY 2000 FLAT PANEL DRAIN. REMOVE EXISTING SAND BACKFILL AND PIPE AND AND DISPOSE OF OFF SITE APPROXIMATE LOCATION OF EXISTING HDPE COLLECTOR PIPE REMOVE EXISTING SAND TRENCH BACKFILL. PIPE IS TO REMAIN. RE: PF3-01 FOR MODIFICATIONS AND ADJUSTMENTS EXISTING TRENCH/SLOT DRAIN TO REMAIN ALL CONNECTION POINTS TO REMAIN INTACT AND UNDISTURBED EXISTING TRENCH/SLOT DRAIN TO REMAIN ALL CONNECTION POINTS TO REMAIN INTACT AND UNDISTURBED EXISTING TRENCH/SLOT DRAIN TO REMAIN ALL CONNECTION POINTS TO REMAIN INTACT AND UNDISTURBED EXISTING TRENCH/SLOT DRAIN TO REMAIN ALL CONNECTION POINTS TO REMAIN INTACT AND UNDISTURBED PLAYING FIELD DEMOLITION NOTES 1. PROTECT PERIMETER TRACK SURFACE FROM DAMAGE FROM ALL CONSTRUCTION ACTIVITIES AND ALL CONSTRUCTION TRAFFIC. CONTRACTOR IS TO REPAIR OR REPLACE AREAS OF TRACK SURFACE DAMAGED BY PLAYING FIELD CONSTRUCTION OPERATIONS TO THE SATISFACTION OF AND AT NO COST TO THE OWNER. 2. IT IS THE CONTRACTOR'S RESPONSIBILITY TO LOCATE ANY AND ALL UTILITIES WITHIN PROJECT LIMITS PRIOR TO COMMENCEMENT OF EXCAVATION ACTIVITIES. 3. REMOVE ALL EXISTING IRRIGATION HEADS AND VALVES, LOCATED WITHIN PROJECT LIMITS AND DELIVER TO OWNER FOR FUTURE USE, PRIOR TO COMMENCEMENT OF EXCAVATION ACTIVITIES. ALL IRRIGATION PIPING IS TO BE REMOVED AND DISPOSED OF OFF-SITE. 4. STORMWATER SUB-DRAINAGE PIPING, STRUCTURES, AND TRENCH BACKFILL MATERIALS ARE TO BE REMOVED AND DISPOSED OF OFF-SITE, UNLESS OTHERWISE INDICATED. 5. NOTIFY PLAYING FIELD DESIGNER IMMEDIATELY OF ANY CONDITIONS NOT INDICATED HEREIN. APPROXIMATE LOCATION OF EXISTING 6" MAINLINE SERVICE AND SHUTOFF VALVE TO REMAIN FOR FUTURE CONNECTION POINT NUMBER NORTHING EASTING ELEVATION DESCRIPTION 350 681370.59 2137806.67 1153.15 NORMAN BRASS MONUMENT 362 681779.26 2135543.09 1160.63 #4 BAR 363 682247.46 2135508.64 1162.32 #4 BAR HORIZONTAL AND VERTICAL DATUM BASED ON THE CITY OF NORMAN CONTROL MONUMENTS HORIZONTAL DATUM: NAD83 (2011), OKLAHOMA STATE PLANE, SOUTH ZONE VERTICAL DATUM: NAVD88 PLAYING FIELD EXISTING SUBDRAINAGE NOTES: KNOWN INFORMATION 1. LATERAL PIPING IS HYDRAWAY 2000 (OR SIMILAR) DRAIN PIPE PLACED VERTICALLY IN A SAND FILLED TRENCH. 2. LATERAL PIPING IS CONNECTED TO A HDPE PERIMETER COLLECTOR. TYPE (PERFORATED OR NON-PERFORATED) AND SIZE OF PIPE IS UNKNOWN. 3. THE PRESENCE OF CLEANOUTS ALONG THE COLLECTOR PIPING IS UNKNOWN. ASSUMPTIONS 1. LOCATIONS OF LATERAL AND COLLECTOR PIPING WERE DETERMINED THROUGH VISIBILITY IN AERIAL IMAGERY. 2. EXISTING DRAIN LINES HAVE POSITIVE SLOPE TO THE OUTFALL. 3. THE OUTFALL IS LOCATED IN THE SOUTHEAST CORNER OF THE TRACK AREA, AS INDICATED, FLOWING EAST TO THE DUCK POND. 4. EXISTING COLLECTOR PIPING HAS BEEN ADEQUATELY SIZED AND IS CAPABLE OF CARRYING STORMWATER RUNOFF FOR THE REQUIRED DESIGN STORM ACCORDING TO LOCAL CODES. CONTRACTOR RESPONSIBILITY 1. CONTRACTOR SHALL FIELD LOCATE AND DETERMINE COLLECTOR PIPE SIZE AND TYPE AND SHALL NOTIFY THE FIELD DESIGNER OF THESE FINDINGS. 2. CONTRACTOR SHALL DETERMINE THE PRESENCE OF CLEANOUTS ALONG THE COLLECTOR LINE AND PROVIDE LOCATIONS TO THE FIELD DESIGNER. SHOULD NO CLEANOUTS BE LOCATED, CLEANOUTS ARE TO BE ADDED AT THE INDICATED LOCATIONS. 3. CONTRACTOR SHALL DETERMINE THE INVERT ELEVATIONS AT PROPOSED CLEANOUT LOCATIONS. IF CLEANOUTS ARE PRESENT IN THE EXISTING INSTALLATION, THIS IS NOT REQUIRED. 4. CONTRACTOR IS TO VERIFY POSITIVE SLOPE ALONG THE COLLECTOR PIPE ROUTING, TO THE OUTFALL. ADJUST PIPING AS REQUIRED TO PROVIDE A MINIMUM SLOPE OF 0.5% ALONG THE COLLECTOR PIPE ROUTING, TO THE OUTFALL. EXISTING RUNNING TRACK TO REMAIN UNDISTURBED EXISTING RUNNING TRACK TO REMAIN UNDISTURBED LIMITS OF DEMOLITION LIMITS OF DEMOLITION LIMITS OF DEMOLITION LIMITS OF DEMOLITION LIMITS OF DEMOLITION LIMITS OF DEMOLITION LIMITS OF DEMOLITION EXISTING UNDERGROUND COMMUNICATION LINE TO REMAIN Attachment #2

Upload: others

Post on 18-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PF0-01 EXISTING CONDITIONS AND DEMOLITION PLAN · scale: 1/16" = 1'-0" 2 4 8 true north existing conditions and demolition plan pf0-01 existing shot-put pad to remain undisturbed

1158.5

1158.5

1159.0

1159.0

1158.6

1158.6

1158.7

1158.7

1158.8

1158.8

1158.9

1158.9

1159.1

1159.1

1159.2

PROJECT NO. ISSUED BY:

ISSUEDDATE:

TITLE:

DISCIPLINE - CATEGORY - SUB CATEGORY - SHEET

REVISIONS

Playing Field Design4800 Main Street, Suite 300Kansas City, Missouri, 64112816.221.1500

TM

Cardinal Engineering525 Central Park Drive, Suite 500Oklahoma City, Oklahoma 73105405-842-1066

Civil Engineer

JAC

OB

S T

RAC

K A

ND

FIE

LD

FAC

ILIT

YIN

FIE

LD

Renovatio

nN

orman, O

klahoma

FOR

REFE

RENC

E ON

LY -

NOT

FOR

CONS

TRUC

TION

CONSTRUCTIONDOCUMENTSAPRIL 17, 2020

19.4930

REV # DATE DESCRIPTION

04.17.2020

Copyright 2020 ©

4/17/2

020 9

:30 P

M

LEGEND

PLAYING FIELD DEMOLITION PLAN1/16" = 1'-0"

0 3216

SCALE: 1/16" = 1'-0"

2 4 8

TRUE NORTH

EXISTING CONDITIONSAND DEMOLITION PLAN

PF0-01

EXISTING SHOT-PUT PADTO REMAIN UNDISTURBED

EXISTING SHOT-PUT PADTO REMAIN UNDISTURBED

EXISTING SHOT-PUT PADTO REMAIN UNDISTURBED

EXISTING RUNNING TRACKTO REMAIN UNDISTURBED

EXISTING RUNNING TRACKTO REMAIN UNDISTURBED

EXISTING RUNNING TRACKTO REMAIN UNDISTURBED

EXISTING RUNNING TRACKTO REMAIN UNDISTURBED

EXISTING RUNNING TRACKTO REMAIN UNDISTURBED

EXISTING RUNNING TRACKTO REMAIN UNDISTURBED

EXCAVATE TODESIGNED SUBGRADEAND REMOVEOFF-SITE, ALL PLAYINGFIELD MATERIALSINCLUDING, BUT NOTLIMITED TO:1. SOD2. ROOTZONE3. DRAINAGE

GRAVEL4. IRRIGATION

EQUIPMENT ANDPIPING

APPROXIMATE LOCATIONOF EXISTING VERTICALLYPLACED HYDRAWAY2000 FLAT PANEL DRAIN.REMOVE EXISTING SANDBACKFILL AND PIPE ANDAND DISPOSE OF OFF SITE

APPROXIMATE LOCATIONOF EXISTING HDPECOLLECTOR PIPEREMOVE EXISTING SANDTRENCH BACKFILL. PIPE ISTO REMAIN.RE: PF3-01 FORMODIFICATIONS ANDADJUSTMENTS

EXISTING TRENCH/SLOT DRAIN TO REMAINALL CONNECTION POINTS TO REMAININTACT AND UNDISTURBED

EXISTING TRENCH/SLOT DRAIN TO REMAINALL CONNECTION POINTS TO REMAININTACT AND UNDISTURBED

EXISTING TRENCH/SLOT DRAIN TO REMAINALL CONNECTION POINTS TO REMAIN

INTACT AND UNDISTURBED

EXISTING TRENCH/SLOT DRAIN TO REMAINALL CONNECTION POINTS TO REMAIN

INTACT AND UNDISTURBED

PLAYING FIELDDEMOLITION NOTES1. PROTECT PERIMETER TRACK SURFACE

FROM DAMAGE FROM ALLCONSTRUCTION ACTIVITIES AND ALLCONSTRUCTION TRAFFIC.CONTRACTOR IS TO REPAIR ORREPLACE AREAS OF TRACK SURFACEDAMAGED BY PLAYING FIELDCONSTRUCTION OPERATIONS TO THESATISFACTION OF AND AT NO COSTTO THE OWNER.

2. IT IS THE CONTRACTOR'SRESPONSIBILITY TO LOCATE ANY ANDALL UTILITIES WITHIN PROJECT LIMITSPRIOR TO COMMENCEMENT OFEXCAVATION ACTIVITIES.

3. REMOVE ALL EXISTING IRRIGATIONHEADS AND VALVES, LOCATEDWITHIN PROJECT LIMITS AND DELIVERTO OWNER FOR FUTURE USE, PRIORTO COMMENCEMENT OFEXCAVATION ACTIVITIES. ALLIRRIGATION PIPING IS TO BEREMOVED AND DISPOSED OFOFF-SITE.

4. STORMWATER SUB-DRAINAGEPIPING, STRUCTURES, AND TRENCHBACKFILL MATERIALS ARE TO BEREMOVED AND DISPOSED OFOFF-SITE, UNLESS OTHERWISEINDICATED.

5. NOTIFY PLAYING FIELD DESIGNERIMMEDIATELY OF ANY CONDITIONSNOT INDICATED HEREIN.

APPROXIMATE LOCATION OF EXISTING6" MAINLINE SERVICE AND SHUTOFF VALVE

TO REMAIN FOR FUTURE CONNECTION

POINT NUMBER NORTHING EASTING ELEVATION DESCRIPTION350 681370.59 2137806.67 1153.15 NORMAN BRASS MONUMENT362 681779.26 2135543.09 1160.63 #4 BAR363 682247.46 2135508.64 1162.32 #4 BAR

HORIZONTAL AND VERTICAL DATUM BASED ON THE CITY OF NORMAN CONTROL MONUMENTSHORIZONTAL DATUM: NAD83 (2011), OKLAHOMA STATE PLANE, SOUTH ZONE

VERTICAL DATUM: NAVD88

PLAYING FIELD EXISTING SUBDRAINAGE NOTES:KNOWN INFORMATION1. LATERAL PIPING IS HYDRAWAY 2000 (OR SIMILAR) DRAIN PIPE PLACED VERTICALLY IN A SAND FILLED TRENCH.2. LATERAL PIPING IS CONNECTED TO A HDPE PERIMETER COLLECTOR. TYPE (PERFORATED OR

NON-PERFORATED) AND SIZE OF PIPE IS UNKNOWN.3. THE PRESENCE OF CLEANOUTS ALONG THE COLLECTOR PIPING IS UNKNOWN.

ASSUMPTIONS1. LOCATIONS OF LATERAL AND COLLECTOR PIPING WERE DETERMINED THROUGH VISIBILITY IN AERIAL

IMAGERY.2. EXISTING DRAIN LINES HAVE POSITIVE SLOPE TO THE OUTFALL.3. THE OUTFALL IS LOCATED IN THE SOUTHEAST CORNER OF THE TRACK AREA, AS INDICATED, FLOWING EAST TO

THE DUCK POND.4. EXISTING COLLECTOR PIPING HAS BEEN ADEQUATELY SIZED AND IS CAPABLE OF CARRYING STORMWATER

RUNOFF FOR THE REQUIRED DESIGN STORM ACCORDING TO LOCAL CODES.

CONTRACTOR RESPONSIBILITY1. CONTRACTOR SHALL FIELD LOCATE AND DETERMINE COLLECTOR PIPE SIZE AND TYPE AND SHALL NOTIFY THE

FIELD DESIGNER OF THESE FINDINGS.2. CONTRACTOR SHALL DETERMINE THE PRESENCE OF CLEANOUTS ALONG THE COLLECTOR LINE AND PROVIDE

LOCATIONS TO THE FIELD DESIGNER. SHOULD NO CLEANOUTS BE LOCATED, CLEANOUTS ARE TO BE ADDEDAT THE INDICATED LOCATIONS.

3. CONTRACTOR SHALL DETERMINE THE INVERT ELEVATIONS AT PROPOSED CLEANOUT LOCATIONS. IFCLEANOUTS ARE PRESENT IN THE EXISTING INSTALLATION, THIS IS NOT REQUIRED.

4. CONTRACTOR IS TO VERIFY POSITIVE SLOPE ALONG THE COLLECTOR PIPE ROUTING, TO THE OUTFALL. ADJUSTPIPING AS REQUIRED TO PROVIDE A MINIMUM SLOPE OF 0.5% ALONG THE COLLECTOR PIPE ROUTING, TOTHE OUTFALL.

EXISTING RUNNING TRACKTO REMAIN UNDISTURBED

EXISTING RUNNING TRACKTO REMAIN UNDISTURBED

LIMITS OF DEMOLITION LIMITS OF DEMOLITION

LIMITS

OF D

EMO

LITIO

N

LIMITS OF DEMOLITION LIMITS OF DEMOLITION

LIM

ITS O

F D

EMO

LITIO

N

LIMITS O

F DEMO

LITION

EXISTING UNDERGROUNDCOMMUNICATION LINETO REMAIN

Attachment #2

AutoCAD SHX Text
1158.5
AutoCAD SHX Text
1158.7
AutoCAD SHX Text
1159.0
AutoCAD SHX Text
1158.9
AutoCAD SHX Text
1158.9
AutoCAD SHX Text
1158.5
AutoCAD SHX Text
1158.5
AutoCAD SHX Text
1158.9
AutoCAD SHX Text
1159.1
AutoCAD SHX Text
1159.1
AutoCAD SHX Text
1158.8
AutoCAD SHX Text
1158.6
AutoCAD SHX Text
1158.5
AutoCAD SHX Text
1158.9
AutoCAD SHX Text
1159.2
AutoCAD SHX Text
1159.1
AutoCAD SHX Text
1158.8
AutoCAD SHX Text
1158.5
AutoCAD SHX Text
1158.6
AutoCAD SHX Text
1158.8
AutoCAD SHX Text
1159.1
AutoCAD SHX Text
1159.2
AutoCAD SHX Text
1158.9
AutoCAD SHX Text
1158.5
AutoCAD SHX Text
1158.6
AutoCAD SHX Text
1158.9
AutoCAD SHX Text
1159.1
AutoCAD SHX Text
1159.1
AutoCAD SHX Text
1158.8
AutoCAD SHX Text
1158.5
AutoCAD SHX Text
1158.5
AutoCAD SHX Text
1158.8
AutoCAD SHX Text
1159.1
AutoCAD SHX Text
1159.1
AutoCAD SHX Text
1158.9
AutoCAD SHX Text
1158.6
AutoCAD SHX Text
1158.4
AutoCAD SHX Text
1158.6
AutoCAD SHX Text
1158.7
AutoCAD SHX Text
1158.7
AutoCAD SHX Text
1158.6
AutoCAD SHX Text
1158.3
AutoCAD SHX Text
D
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
I, WILLIAM SULLIVAN, certify that this horizontal/vertical control survey was completed under my direct and responsible charge from an actual survey made under my supervision and meets the Oklahoma Minimum Standards for the Practice of Land Surveying as adopted by the Oklahoma State Board of Licensure for Professional Engineers and Land Surveyors. Control Notes: 1. All horizontal coordinate values shown are U.S. Survey feet and all All horizontal coordinate values shown are U.S. Survey feet and all all vertical elevation values are shown in feet. 2. All control points are based on initial City of norman control point All control points are based on initial City of norman control point 350 and was used as a basis for horizontal and vertical control, and used as a basis of bearing. 3. All bearings and distances are derived from the Oklahoma State All bearings and distances are derived from the Oklahoma State Plane Coordinate System, NAD 83, South Zone, as determined by RTK Observations in U.S. survey feet. All field measurements and Observations in U.S. survey feet. All field measurements and angles applied to control points were made with a Topcon GR3 and Trimble RTK . 4. All elevations of control points are based on initial elevation of All elevations of control points are based on initial elevation of Norman Monument 350, the datum is NAVD88. All elevations are determined by RTK .01' accuracy. RTK .01' accuracy. 5. All on-site control points were observed on March 24, 2020. All on-site control points were observed on March 24, 2020.
AutoCAD SHX Text
1-800-522-6543
AutoCAD SHX Text
OKIE
AutoCAD SHX Text
CALL OKIE
AutoCAD SHX Text
BEFORE
AutoCAD SHX Text
YOU DIG..
AutoCAD SHX Text
SURVEYOR'S CONTROL CERTIFICATE
AutoCAD SHX Text
UTILITY WARNING: The underground utilities shown have been located from record documents or field locations by the operator. The surveyor makes no guarantee that the underground utilities shown comprise all such utilities in the area either in service or abandoned. The surveyor further does not warrant that the underground utilities shown are in the exact location indicated although the surveyor does certify that they are located as accurately as possible from the information available. The surveyor has not physically located the underground utilities. Utility elevations and sizes may have been measured under adverse field conditions. Upon exposing the utility, elevations and line sizes should be verified by the contractor prior to construction. Contractor should verify critical elevations using the benchmark provided by the surveyor or engineer. Any discrepancies should be immediately brought to the engineer's and surveyor's attention. Call OKIE Ticket Nos. 20031814372803
AutoCAD SHX Text
SURVEY CONTROL
AutoCAD SHX Text
STORM DRAIN MANHOLE
AutoCAD SHX Text
D
AutoCAD SHX Text
RUBBER TRACK PAD
AutoCAD SHX Text
STORM DRAIN LINE
AutoCAD SHX Text
UNDERGROUND TELEPHONE LINE
AutoCAD SHX Text
GROUND SURFACE CONTOUR
AutoCAD SHX Text
1185
AutoCAD SHX Text
X 1123.5
AutoCAD SHX Text
SPOT ELEVATION
AutoCAD SHX Text
COMMUNICATIONS VAULT
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
SPRINKLER VALVE
AutoCAD SHX Text
SPRINKLER HEAD
AutoCAD SHX Text
TOPOGRAPHIC LEGEND
AutoCAD SHX Text
SURVEYOR
AutoCAD SHX Text
SURVEY INFORMATION WAS PROVIDED BY LEMKE LAND SURVEYING, 3226 BART CONNER DRIVE, NORMAN, OK, 73072 PHONE (405) 366-8541, CA #2054.
AutoCAD SHX Text
MEMBERS NOTIFIED: S00376 USIC/Cox Comm/OKC S00376 USIC/Cox Comm/OKC S00376 S00444 USIC/ONG/West OK S00444 USIC/ONG/West OK S00444 T03165 IndianNation/ChickTel ... IndianNation/ChickTel ... T09079 Norman City of T09079 Norman City of T09079 S00442 USIC/OG&E OKC METRO S00442 USIC/OG&E OKC METRO S00442 T06080 Oklahoma University of/... Oklahoma University of/... T11158 AT&T Distribution T11158AT&T Distribution T11158
Page 2: PF0-01 EXISTING CONDITIONS AND DEMOLITION PLAN · scale: 1/16" = 1'-0" 2 4 8 true north existing conditions and demolition plan pf0-01 existing shot-put pad to remain undisturbed

S89° 46' 47.74"E

S00°

13'

12.

26"W

CENTER OF FIELDN: 681921.06E: 2136103.68

CORNER OF FIELDN: 682001.76E: 2135923.99

CORNER OF FIELDN: 681841.76E: 2135923.38

CORNER OF FIELDN: 682000.37

E: 2136283.99

CORNER OF FIELDN: 681840.37

E: 2136283.37

86'-0

1 8"85

'-111 2"

187'-678"

80'-0

"80

'-0"

180'-0" 180'-0"

187'-638"

PROJECT NO. ISSUED BY:

ISSUEDDATE:

TITLE:

DISCIPLINE - CATEGORY - SUB CATEGORY - SHEET

REVISIONS

Playing Field Design4800 Main Street, Suite 300Kansas City, Missouri, 64112816.221.1500

TM

Cardinal Engineering525 Central Park Drive, Suite 500Oklahoma City, Oklahoma 73105405-842-1066

Civil Engineer

JAC

OB

S T

RAC

K A

ND

FIE

LD

FAC

ILIT

YIN

FIE

LD

Renovatio

nN

orman, O

klahoma

FOR

REFE

RENC

E ON

LY -

NOT

FOR

CONS

TRUC

TION

CONSTRUCTIONDOCUMENTSAPRIL 17, 2020

19.4930

REV # DATE DESCRIPTION

04.17.2020

Copyright 2020 ©

4/17/2

020 9

:32 P

M

LEGENDNATURAL TURFPROFILE

PLAYING FIELD LAYOUT & MATERIALS PLAN1/16" = 1'-0"

0 3216

SCALE: 1/16" = 1'-0"

2 4 8

TRUE NORTH

PLAYING FIELDLAYOUT & MATERIALS

PLAN

PF1-01

FIELDCENTERLINE

50 Y

ARD

LIN

E50

YA

RD L

INE

END

LIN

E

GO

AL

LIN

E

END

LIN

E

GO

AL

LIN

E

GO

AL

LIN

EG

OA

L LI

NE

END

LIN

EEN

D L

INE

SIDE LINE SIDE LINE

SIDE LINESIDE LINE

EXISTING SHOT-PUT PADTO REMAIN UNDISTURBED

EXISTING SHOT-PUT PADTO REMAIN UNDISTURBED

EXISTING SHOT-PUT PADTO REMAIN UNDISTURBED

EXISTING RUNNING TRACKTO REMAIN UNDISTURBED

EXISTING RUNNING TRACKTO REMAIN UNDISTURBED

EXISTING RUNNING TRACKTO REMAIN UNDISTURBED

EXISTING RUNNING TRACKTO REMAIN UNDISTURBED

EXISTING RUNNING TRACKTO REMAIN UNDISTURBED

EXISTING RUNNING TRACKTO REMAIN UNDISTURBED

FIELD MARKINGS SHOWN FOR REFERENCE ONLYFIELD MARKINGS TO BE APPLIED BY GROUNDSKEEPER

FIELD MARKINGS SHOWN FOR REFERENCE ONLYFIELD MARKINGS TO BE APPLIED BY GROUNDSKEEPER

TOP OF SYNTHETIC TRACK MATERIAL

COMPACTED SUBGRADE

NATURAL TURF PROFILE @ PERIMETER TRACK1 1/2" = 1'SECTION VIEW

NATURAL TURF PROFILE1/

4"

PERIMETER TRACK PROFILE

B

COMPACTED SUBGRADE

SODDED TURF

6"

NATURAL TURF PROFILE2" = 1'

SOD THICKNESS

USGA ROOTZONE MIXPER SPECIFICATIONS

GEOTEXTILE FABRIC ACROSSENTIRE SUBGRADE

A

A/THIS SHEETNATURAL TURF

PROFILE

A/THIS SHEETNATURAL TURF

PROFILE

PLAYING FIELDNOTES1. ALL FIELD MARKINGS ARE FOR

REFERNCE ONLY. APPLICATIONBY GROUNDSKEEPER.

2. ROOTZONE MIX TO BE BLENDEDOFF-SITE. DELIVERY ANDSTORAGE OF APPROVED MIXON-SITE TO BE COORDINATEDWITH THE CONSTRUCTIONMANAGER.

3. ALL DIMENSION UNITS ARE GIVENIN FEET UNLESS OTHERWISENOTED.

4. ALL FIELD DIMENSIONS,MARKINGS, AND MATERIALS ARESYMMETRICAL ABOUT THE FIELDCENTERLINES AND MIDFIELD LINESUNLESS OTHERWISE NOTED.

5. INSTALL FIELD MARKING PINS ATTHE CORNERS OF THE FIELD TOAID IN FIELD MARKINGOPERATIONS.

AutoCAD SHX Text
D
Page 3: PF0-01 EXISTING CONDITIONS AND DEMOLITION PLAN · scale: 1/16" = 1'-0" 2 4 8 true north existing conditions and demolition plan pf0-01 existing shot-put pad to remain undisturbed

1158.5

1158.5

1159.0

1159.0

1158.6

1158.6

1158.7

1158.7

1158.8

1158.8

1158.9

1158.9

1159.1

1159.1

1159.2

FG 11

58.45

FG 1158.45

FG 11

58.45

FG 1158.45

FG 11

58.45

FG 1158.45

HP 1159

.05

HP 1159

.05

HP 1159

.05

1158.50

1158.60

1158.70

1158.80

1158.90

1159.00

1158.50

1158.60

1158.70

1158.80

1158.90

1159.00

1158

.40

1158

.30

1158

.20

1158

.40

1158.40

1158.40

P 1158

.24

MATCH EX

.

P 1158

.21

MATCH EX

.

P 1158.23

MATCH EX.

P 1158.24

MATCH EX.

P 1158

.41

MATCH EX

.

P 1158.40

MATCH EX.

FG 1158.39

MATCH EX.

FG 11

58.42

MATCH EX

.P 11

58.22

MATCH EX

.

P 1158

.17

MATCH EX

.

P 1158.17

MATCH EX.

P 1158.25

MATCH EX.

PROJECT NO. ISSUED BY:

ISSUEDDATE:

TITLE:

DISCIPLINE - CATEGORY - SUB CATEGORY - SHEET

REVISIONS

Playing Field Design4800 Main Street, Suite 300Kansas City, Missouri, 64112816.221.1500

TM

Cardinal Engineering525 Central Park Drive, Suite 500Oklahoma City, Oklahoma 73105405-842-1066

Civil Engineer

JAC

OB

S T

RAC

K A

ND

FIE

LD

FAC

ILIT

YIN

FIE

LD

Renovatio

nN

orman, O

klahoma

FOR

REFE

RENC

E ON

LY -

NOT

FOR

CONS

TRUC

TION

CONSTRUCTIONDOCUMENTSAPRIL 17, 2020

19.4930

REV # DATE DESCRIPTION

04.17.2020

Copyright 2020 ©

4/17/2

020 9

:34 P

M

LEGENDNATURAL TURFPROFILE

MATCH EXISTING ELEVATIONENTIRE PERIMETER

PLAYING FIELD GRADING PLAN1/16" = 1'-0"

0 3216

SCALE: 1/16" = 1'-0"

2 4 8

TRUE NORTH

PLAYING FIELDGRADING PLAN

PF2-00

MATCH EXISTING ELEVATIONENTIRE PERIMETER

MATCH EXISTING ELEVATIONENTIRE PERIMETER

MATCH EXISTING ELEVATIONENTIRE PERIMETER

MATCH EXISTING ELEVATIONENTIRE PERIMETER

MATCH EXISTING ELEVATIONENTIRE PERIMETER

FIELDCENTERLINE

50 Y

ARD

LIN

E50

YA

RD L

INE

HIGH POINTELEVATIONHP XX.XX

EXISTING MAJORCONTOUR300

EXISTING MINORCONTOUR301

PROPOSEDMAJOR CONTOUR300

PROPOSED MINORCONTOUR301

PLAYING FIELDNOTES1. GRADE FIELD TO A SMOOTH, EVEN

PLAYING SURFACE TO THE SPOTELEVATIONS AND CONTOURSINDICATED.

2. CONTOUR INTERVAL IS ONE-TENTHFOOT, UNLESS OTHERWISE INDICATED.

FINISHED GRADEELEVATIONFG XX.XX

END

LIN

E

GO

AL

LIN

E

END

LIN

E

GO

AL

LIN

E

GO

AL

LIN

EG

OA

L LI

NE

END

LIN

EEN

D L

INE

SIDE LINE SIDE LINE

SIDE LINESIDE LINE

AutoCAD SHX Text
D
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
V
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
S
Page 4: PF0-01 EXISTING CONDITIONS AND DEMOLITION PLAN · scale: 1/16" = 1'-0" 2 4 8 true north existing conditions and demolition plan pf0-01 existing shot-put pad to remain undisturbed

1158.5

1158.5

1159.0

1159.0

1158.6

1158.6

1158.7

1158.7

1158.8

1158.8

1158.9

1158.9

1159.1

1159.1

1159.2

1158.50

1158.60

1158.70

1158.80

1158.90

1159.00

1158.50

1158.60

1158.70

1158.80

1158.90

1159.00

1158

.40

1158

.30

1158

.20

1158

.40

1158.40

1158.40

PROJECT NO. ISSUED BY:

ISSUEDDATE:

TITLE:

DISCIPLINE - CATEGORY - SUB CATEGORY - SHEET

REVISIONS

Playing Field Design4800 Main Street, Suite 300Kansas City, Missouri, 64112816.221.1500

TM

Cardinal Engineering525 Central Park Drive, Suite 500Oklahoma City, Oklahoma 73105405-842-1066

Civil Engineer

JAC

OB

S T

RAC

K A

ND

FIE

LD

FAC

ILIT

YIN

FIE

LD

Renovatio

nN

orman, O

klahoma

FOR

REFE

RENC

E ON

LY -

NOT

FOR

CONS

TRUC

TION

CONSTRUCTIONDOCUMENTSAPRIL 17, 2020

19.4930

REV # DATE DESCRIPTION

04.17.2020

Copyright 2020 ©

4/17/2

020 9

:34 P

M

PLAYING FIELD SUBDRAINAGE NOTES:KNOWN INFORMATION1. LATERAL PIPING IS HYDRAWAY 2000 (OR SIMILAR) DRAIN PIPE PLACED VERTICALLY IN A SAND FILLED TRENCH.2. LATERAL PIPING IS CONNECTED TO A HDPE PERIMETER COLLECTOR. TYPE (PERFORATED OR

NON-PERFORATED) AND SIZE OF PIPE IS UNKNOWN.3. THE PRESENCE OF CLEANOUTS ALONG THE COLLECTOR PIPING IS UNKNOWN.

ASSUMPTIONS1. LOCATIONS OF LATERAL AND COLLECTOR PIPING WERE DETERMINED THROUGH VISIBILITY IN AERIAL

IMAGERY.2. EXISTING DRAIN LINES HAVE POSITIVE SLOPE TO THE OUTFALL.3. THE OUTFALL IS LOCATED IN THE SOUTHEAST CORNER OF THE TRACK AREA, AS INDICATED, FLOWING EAST TO

THE DUCK POND.4. EXISTING COLLECTOR PIPING HAS BEEN ADEQUATELY SIZED AND IS CAPABLE OF CARRYING STORMWATER

RUNOFF FOR THE REQUIRED DESIGN STORM ACCORDING TO LOCAL CODES.

CONTRACTOR RESPONSIBILITY1. CONTRACTOR SHALL FIELD LOCATE AND DETERMINE COLLECTOR PIPE SIZE AND TYPE AND SHALL NOTIFY THE

FIELD DESIGNER OF THESE FINDINGS.2. CONTRACTOR SHALL DETERMINE THE PRESENCE OF CLEANOUTS ALONG THE COLLECTOR LINE AND PROVIDE

LOCATIONS TO THE FIELD DESIGNER. SHOULD NO CLEANOUTS BE LOCATED, CLEANOUTS ARE TO BE ADDEDAT THE INDICATED LOCATIONS.

3. CONTRACTOR SHALL DETERMINE THE INVERT ELEVATIONS AT PROPOSED CLEANOUT LOCATIONS. IFCLEANOUTS ARE PRESENT IN THE EXISTING INSTALLATION, THIS IS NOT REQUIRED.

4. CONTRACTOR IS TO VERIFY POSITIVE SLOPE ALONG THE COLLECTOR PIPE ROUTING, TO THE OUTFALL. ADJUSTPIPING AS REQUIRED TO PROVIDE A MINIMUM SLOPE OF 0.5% ALONG THE COLLECTOR PIPE ROUTING, TOTHE OUTFALL.

COMPACTED SUBGRADE

DRAINAGE GRAVEL

ROOTZONE MIX

SODDED TURF

6"

FLAT PANEL SUB-DRAINAGE LATERAL 2" = 1'

FLAT PANEL SUB-DRAINAGELATERAL PIPE. MIN. 4"DRAINAGE GRAVELABOVE PIPE. MIN. 2"DRAINAGE GRAVEL BELOWPIPE

4" M

IN.

GEOTEXTILE FABRICWRAP BOTTOM AND SIDESOF TRENCH. OVERLAPSUBGRADE 12".

4" MIN.

A

LEGEND

EXISTING MAJORCONTOUR300

EXISTING MINORCONTOUR301

PROPOSEDMAJOR CONTOUR300

PROPOSED MINORCONTOUR301

APPROXIMATE LOCATIONOF EXISTING VERTICALLYPLACED HYDRAWAY2000 FLAT PANEL DRAIN.REMOVE EXISTING SANDBACKFILL AND PIPE ANDINSTALL 12" ADSADVANEDGE AS SHOWNIN DETAIL A BELOWWITHIN EXISTING TRENCHENSURE MINIMUM SLOPEOF 0.5% TO COLLECTOR

APPROXIMATE LOCATIONOF EXISTING HDPECOLLECTOR PIPEREMOVE EXISTING SANDTRENCH BACKFILL,ADJUST PIPE AS REQUIREDTO ACHIEVE MINIMUM0.5% SLOPE TO OUTFALLBACKFILL TRENCHES WITHDRAINAGE GRAVEL

NATURAL TURFPROFILE

ASSUMED CONNECTION POINT TO OUTFALL

PROPOSED CLEANOUT IF REQUIREDINVERT ELEVATIONS TO BE DETERMINEDBY CONTRACTOR

PROPOSED CLEANOUT IF REQUIREDINVERT ELEVATIONS TO BE DETERMINEDBY CONTRACTOR

PROPOSED CLEANOUT IF REQUIREDINVERT ELEVATIONS TO BE DETERMINEDBY CONTRACTOR

PROPOSED CLEANOUT IF REQUIREDINVERT ELEVATIONS TO BE DETERMINEDBY CONTRACTOR

EXISTING STORM STRUCTURE ANDOUTFALL TO DUCK POND

GEOTEXTILE FILTER FABRIC WRAPBOTTOM & SIDES. EXTEND 12" PASTTOP OF TRENCH ON SUBGRADE.

PERFORATED COLLECTOR PIPE 2"GRAVEL BELOW BOTTOM OF PIPE.4" MIN. GRAVEL ABOVE TOP OFPIPE.

4" MIN

.2"

2x PIPE DIAMETERMIN.

4" MIN

.

DRAINAGE GRAVEL

FIELD LATERAL BEYOND.

PERIMETER SUB-DRAINAGE COLLECTOR PIPE2" = 1'SECTION VIEW

COMPACTED SUBGRADE

NOTE: TRENCH WIDTH IS TOBE 2 X THE PIPE DIA.

ROOTZONE MIX

SODDED TURF

6"

B

PERFORATED COLLECTOR PIPE4" MIN. GRAVEL ABOVE TOP OFPIPE.

GEOTEXTILE FILTER FABRICWRAP BOTTOM & SIDES.EXTEND 12" PAST TOP OFTRENCH ON SUBGRADE.

2x PIPE DIAMETERMIN.

2"

DRAINAGE GRAVEL

COMPACTED SUBGRADE

CENTER COLLECTOR PIPE CLEAN-OUT2" = 1'

GEOTEXTILE FABRIC ATOP GRATE

NYLOPLAST DRAIN BASIN WITHSTANDARD GRATE. 2" GRAVELBELOW BOTTOM OF BASIN.

SECTION VIEW

ROOTZONE MIX

SODDED TURF

6"

C

PLAYING FIELD SUBDRAINAGE PLAN1/16" = 1'-0"

0 3216

SCALE: 1/16" = 1'-0"

2 4 8

TRUE NORTH

PLAYING FIELDSUBDRAINAGE PLAN

PF3-01

PROPOSED CLEANOUT IF REQUIREDINVERT ELEVATIONS TO BE DETERMINEDBY CONTRACTOR

PROPOSED CLEANOUT IF REQUIREDINVERT ELEVATIONS TO BE DETERMINEDBY CONTRACTOR

VERTIC

ALLY PLA

CED FL

AT PANEL

DRAIN A

T 0.5%

SLOPE -

TYP.

VERTIC

ALLY PLA

CED FL

AT PANEL

DRAIN A

T 0.5%

SLOPE -

TYP.

VERTIC

ALLY PLA

CED FL

AT PANEL

DRAIN A

T 0.5%

SLOPE -

TYP.

VERTICALLY PLACED FLAT PANEL DRAIN AT 0.5% SLOPE - TYP.

VERTICALLY PLACED FLAT PANEL DRAIN AT 0.5% SLOPE - TYP.

VERTICALLY PLACED FLAT PANEL DRAIN AT 0.5% SLOPE - TYP.

NOTE: DO NOT INSTALL GEOTEXTILE FABRIC OVER TRENCHNOTE: DO NOT INSTALL GEOTEXTILE FABRIC OVER TRENCH

EXISTING TRENCH/SLOT DRAIN TO REMAINALL CONNECTION POINTS TO REMAININTACT AND UNDISTURBED

EXISTING TRENCH/SLOT DRAIN TO REMAINALL CONNECTION POINTS TO REMAININTACT AND UNDISTURBED

EXISTING TRENCH/SLOT DRAIN TO REMAINALL CONNECTION POINTS TO REMAIN

INTACT AND UNDISTURBED

EXISTING TRENCH/SLOT DRAIN TO REMAINALL CONNECTION POINTS TO REMAIN

INTACT AND UNDISTURBED

EXISTING TRENCH/SLOT DRAIN TO REMAINALL CONNECTION POINTS TO REMAININTACT AND UNDISTURBED

EXISTING TRENCH/SLOT DRAIN TO REMAINALL CONNECTION POINTS TO REMAININTACT AND UNDISTURBED

PROPOSED CLEANOUT IF REQUIREDINVERT ELEVATIONS TO BE DETERMINEDBY CONTRACTOR

PLAYING FIELDNOTES1. CONTRACTOR TO AVOID

EXCESSIVE TRAFFIC OVERCOMPLETED DRAINAGESYSTEM TO AVOID CRUSHINGOF PIPE.

2. CONTRACTOR TO PROVIDEPROOF OF POSITIVEDRAINAGE PRIOR TOBACKFILLING OF PIPE.

3. LATERAL PIPING SHALL HAVEA MINIMUM SLOPE OF 0.5%

4. PERIMETER COLLECTOR TOHAVE A MINIMUM SLOPE OF0.5%

AutoCAD SHX Text
200
AutoCAD SHX Text
1158.47
AutoCAD SHX Text
60D NAIL
AutoCAD SHX Text
1001
AutoCAD SHX Text
1158.49
AutoCAD SHX Text
CHECK 200 FROM 350
AutoCAD SHX Text
201
AutoCAD SHX Text
1159.36
AutoCAD SHX Text
60D NAIL
AutoCAD SHX Text
1002
AutoCAD SHX Text
1159.38
AutoCAD SHX Text
CHECK 201 FROM 350
AutoCAD SHX Text
1003 1158.01 AREA INLET 21.5 DIAM
AutoCAD SHX Text
1007
AutoCAD SHX Text
1157.32
AutoCAD SHX Text
AREA INLET 21.5 DIAM
AutoCAD SHX Text
1012
AutoCAD SHX Text
1157.56
AutoCAD SHX Text
AREA INLET 21.5 DIAM
AutoCAD SHX Text
D
AutoCAD SHX Text
2000
AutoCAD SHX Text
1159.40
AutoCAD SHX Text
CHECK 201 FROM 200
Page 5: PF0-01 EXISTING CONDITIONS AND DEMOLITION PLAN · scale: 1/16" = 1'-0" 2 4 8 true north existing conditions and demolition plan pf0-01 existing shot-put pad to remain undisturbed

C1

PROJECT NO. ISSUED BY:

ISSUEDDATE:

TITLE:

DISCIPLINE - CATEGORY - SUB CATEGORY - SHEET

REVISIONS

Playing Field Design4800 Main Street, Suite 300Kansas City, Missouri, 64112816.221.1500

TM

Cardinal Engineering525 Central Park Drive, Suite 500Oklahoma City, Oklahoma 73105405-842-1066

Civil Engineer

JAC

OB

S T

RAC

K A

ND

FIE

LD

FAC

ILIT

YIN

FIE

LD

Renovatio

nN

orman, O

klahoma

FOR

REFE

RENC

E ON

LY -

NOT

FOR

CONS

TRUC

TION

CONSTRUCTIONDOCUMENTSAPRIL 17, 2020

19.4930

REV # DATE DESCRIPTION

04.17.2020

Copyright 2020 ©

4/17/2

020 9

:37 P

M

LEGENDNATURAL TURFPROFILE

0 3216

SCALE: 1/16" = 1'-0"

2 4 8

TRUE NORTH

PLAYING FIELDIRRIGATION PLAN

PF4-01

FIELDCENTERLINE

50 Y

ARD

LIN

E50

YA

RD L

INE

END

LIN

E

GO

AL

LIN

E

END

LIN

E

GO

AL

LIN

E

GO

AL

LIN

EG

OA

L LI

NE

END

LIN

EEN

D L

INE

SIDE LINE SIDE LINE

SIDE LINESIDE LINE

IRRIGATION MAINLINE TO BEINSTALLED A MAXIMUM OF36" FROM THE EDGE OF TURF

IRRIGATION MAINLINE TO BEINSTALLED A MAXIMUM OF36" FROM THE EDGE OF TURF

IRRIGATION MAINLINE TO BEINSTALLED A MAXIMUM OF36" FROM THE EDGE OF TURF

IRRIGATION MAINLINE TO BEINSTALLED A MAXIMUM OF36" FROM THE EDGE OF TURF

TURF ROTOR HEADADJUSTABLE ARCHUNTER I-40-04-SS-8

TURF ROTOR HEADDUAL OPPOSING NOZ.HUNTER I-40-04-SS-ON-18

3" IRRIGATIONMAINLINE PIPE

TURF ROTOR HEADADJUSTABLE ARCHUNTER I-40-04-SS-15

TURF ROTOR HEADADJUSTABLE ARCHUNTER I-40-04-SS-13

QUICK COUPLERHUNTER HQ-44LRC-AW-R

REMOTE CONTROL VALVETORO 220 BRASS VALVES

MANUAL GATE VALVE

IRRIGATION LATERALPIPE - SIZE PER PLAN

PLAYING FIELD IRRIGATION PLAN1/16" = 1'-0"

APPROXIMATE LOCATION OF EXISTING CONTROLLEREXISTING CONTROLLER TO REMAIN - TRADITIONAL WIRINGCONNECT TO NEW VALVE PLACEMENT

POINT OF CONNECTIONAPPROXIMATE LOCATION OF EXISTING

6" MAINLINE SERVICE AND SHUTOFF VALVECONNECT TO EXISTING SHUTOFF VALVE

WITH NEW MAINLINE PIPE

ZONE 1

ZONE 2 ZONE 3

ZONE 4

ZONE 5ZONE 6

1 1/2"1 1/2"1 1/2"

1 1/2"

1 1/2" 1 1/2"

1 1/2"

1 1/2"1 1/2"1 1/2" 1 1/2"

1 1/2"2"2"

2" 2"

2"2"

2" 2"

2" 2"

2" 2"

3"3"

2 1/2"

2 1/2"

2"1

1/2"

1 1/

2"1 1/2"

2"

2"

2"

1 1/2

"

3"

AutoCAD SHX Text
1003 1158.01 AREA INLET 21.5 DIAM
AutoCAD SHX Text
1007
AutoCAD SHX Text
1157.32
AutoCAD SHX Text
AREA INLET 21.5 DIAM
AutoCAD SHX Text
1012
AutoCAD SHX Text
1157.56
AutoCAD SHX Text
AREA INLET 21.5 DIAM
AutoCAD SHX Text
D
Page 6: PF0-01 EXISTING CONDITIONS AND DEMOLITION PLAN · scale: 1/16" = 1'-0" 2 4 8 true north existing conditions and demolition plan pf0-01 existing shot-put pad to remain undisturbed

COMPACTEDSUBGRADE

PVC IRRIGATION LATERAL PIPE

DRAINAGE GRAVEL

ELECTRIC REMOTE CONTROL VALVE

CONCRETE BLOCK/BRICK

DIRECT BURY WIRE CONNECTOR

MANUAL GATE VALVE

IRRIGATION REMOTE CONTROL VALVE BOXINSTALL VALVE BOX WITH LONG END PARALLELTO AND 12" AWAY FROM EDGE OF PERIMETER TRACKTOP OF BOX TO BE 1/2" BELOW FINISHED GRADEAND COVERED WITH SYNTHETIC TURF

IRRIGATION MAIN LINE PIPE INSTALLEDPARALLEL TO PERIMETER TRACK90 UP AND OVER TOREMOTE CONTROL VALVE ALIGNMENT

EXISTING PERIMETER RUNNING TRACK

COMPACTEDSUBGRADE

DRAINAGE GRAVEL

CONCRETE BLOCK/BRICK

IRRIGATION MAIN LINE PIPE

1'-0"

3'-0" MAX.

QUICK COUPLER - TOP OF QUICKCOUPLER TO BE MOUNTED 1/2" BELOWVALVE BOX LID

1/2" REBAR - 24" LENGTHFASTEN TO VALVE WITH STAINLESSSTEEL HOSE CLAMPS

10" ROUND QUICK COUPLER VALVE BOXTOP OF LID TO BE 1/2" BELOW FINISHED GRADEAND COVERED WITH SYNTHETIC TURF

SWING JOINT

PROJECT NO. ISSUED BY:

ISSUEDDATE:

TITLE:

DISCIPLINE - CATEGORY - SUB CATEGORY - SHEET

REVISIONS

Playing Field Design4800 Main Street, Suite 300Kansas City, Missouri, 64112816.221.1500

TM

Cardinal Engineering525 Central Park Drive, Suite 500Oklahoma City, Oklahoma 73105405-842-1066

Civil Engineer

JAC

OB

S T

RAC

K A

ND

FIE

LD

FAC

ILIT

YIN

FIE

LD

Renovatio

nN

orman, O

klahoma

FOR

REFE

RENC

E ON

LY -

NOT

FOR

CONS

TRUC

TION

CONSTRUCTIONDOCUMENTSAPRIL 17, 2020

19.4930

REV # DATE DESCRIPTION

04.17.2020

Copyright 2020 ©

4/17/2

020 9

:50 P

M

0 3216

SCALE: 1/16" = 1'-0"

2 4 8

TRUE NORTH

PLAYING FIELDIRRIGATION DETAILS &

NOTES

PF4-02

14" M

INIM

UM C

OV

ER

FINISH GRADE

ROOTZONE MATERIAL

POP-UP ROTOR SPRINKLER HEADTOP OF HEAD TO BE 1/2"

BELOW FINISH GRADE

SCHEDULE 80 PVC RISER

DRAINAGE GRAVELSWING JOINT

IRRIGATION LATERAL

COMPACTED SUBGRADE

TURF ROTOR INSTALLATION DETAILNTSSECTION VIEWA

MODEL

VALVE SCHEDULESIZEVALVE # GPM

1234

TYPE

5

TORO 220 BRASS VALVE2"

6

2"2"2"2"

OPERATINGPRESSURE

60 PSI

60 PSII-40-04-SS

60 PSI

60 PSI

60 PSI

PIPE SIZE TOFIRST HEAD

2 1/2"

3"

2 1/2"I-40-04-SS-ON

I-40-04-SS62.891.2

91.262.8

2"

I-40-04-SS-ONI-40-04-SS

81.2

105.1

60 PSI

3"

1. THE SYSTEM DESIGN ASSUMES A MINIMUM AVAILABLE STATIC PRESSURE FOR THEIRRIGATION SYSTEM OF 75 PSI AND A MINIMUM FLOW OF 110 GPM AT THECONNECTION TO THE EXISTING IRRIGATION SUPPLY MAIN. VERIFY PRESSURE ANDFLOW ON SITE PRIOR TO CONSTRUCTION AND REPORT ANY DISCREPANCIESBETWEEN THESE ASSUMPTIONS AND ACTUAL FIELD CONDITIONS IN WRITING TO THEOWNER'S REPRESENTATIVE.

2. READ THOROUGHLY AND BECOME FAMILIAR WITH THE SPECIFICATIONS ANDINSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO CONSTRUCTION.

3. COORDINATE LOCATION AND MARKING OF UNDERGROUND UTILITIES PRIOR TOCONSTRUCTION. NOTIFY THE OWNER'S REPRESENTATIVE OF ANY CONFLICT WITHANY UNDERGROUND UTILITY.

4. DO NOT PROCEED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM WHEN IT ISOBVIOUS IN THE FIELD THAT OBSTRUCTIONS OR GRADE DIFFERENCES EXIST THATMIGHT NOT HAVE BEEN CONSIDERED IN THE ENGINEERING, OR IF DISCREPANCIES INCONSTRUCTION DETAILS, LEGEND, NOTES, OR SPECIFICATIONS ARE DISCOVERED.BRING ALL SUCH OBSTRUCTIONS OR DISCREPANCIES TO THE ATTENTION OF THEOWNER'S REPRESENTATIVE IN WRITING PRIOR TO CONSTRUCTION.

5. THESE DRAWINGS ARE DIAGRAMMATIC. THEREFORE, THE FOLLOWING SHOULD BENOTED:A. CONFLICTS BETWEEN THE IRRIGATION SYSTEM, DRAINAGE STRUCTRUES,

PLAYING FIELD EQUIPMENT AND ARCHITECTURAL FEATURES ARE TO BEAVOIDED. THE PLAYING FIELD DESIGNER SHALL BE NOTIFIED OF ANY CONFLICTTHAT ARISES IN THE FIELD.

B. INSTALL IRRIGATION PIPE AND WIRING UNDER PLAYING FIELD GRASS AREA.C. USE ONLY STANDARD TEES AND ELBOW FITTINGS. USE OF CROSS TYPE FITTINGS

IS NOT PERMITTED.

6. GATE VALVES SHALL BE PORTED TO PROVIDE FOR FULL FLOW. LABELED ANDNOMINAL SIZE OF VALVE OPENING SHALL BE THE SAME.

7. ALL MATERIALS AND WORKMANSHIP SHALL BE TRUE TO TYPE, FORM, FINISH AND OFTHE HIGHEST STANDARDS OF THE TRADE. DAMAGED OR INFERIOR MATERIALS SHALLBE REMOVED FROM THE SITE WITHOUT DELAY.

8. PROVIDE #12-1 AWG BARE COPPER TRACING WIRE ALONG THE ENTIRE MAINLINEROUTING. PROVIDE 24 INCH COIL OF TRACING WIRE IN EACH VALVE BOX ALONGMAINLINE ROUTING.

9. CONTRACTOR SHALL FURNISH AND INSTALL MATERIAL AND EQUIPMENT PERTAININGTO THE IRRIGATION SYSTEM HEREIN SPECIFIED OR SHOWN ON THE DRAWINGS. THISSHALL INCLUDE ALL ITEMS NECESSARY TO COMPLETE INSTALLATION.

10. IRRIGATION CONTRACTOR TO CAP ALL FLUSH ENDS HAND TIGHT PRIOR TOBACKFILL.

11. ALL MATERIALS SHALL BE INSTALLED AS DETAILED IN THE PLANS. IF THE CONTRACTDRAWINGS AND/OR SPECIFICATIONS DO NOT THOROUGHLY DESCRIBE THEMETHOD OR TECHNIQUES TO BE USED, THEN THE CONTRACTOR SHALL INSTALL ASPER MANUFACTURERS SPECIFICATIONS. IF A CONTRADICTION OCCURS, NOTIFY THEPLAYING FIELD DESIGNER IMMEDIATELY.

12. IRRIGATION CONTRACTOR TO USE TEFLON TAPE ON ALL THREADED JOINTS.

13. NO PIPES SHALL BE INSTALLED PARALLEL TO AND DIRECTLY OVER ANOTHER LINE.

14. TAG EACH VALVE WITH THE ZONE NUMBER AND CONTROLLER LETTER. THIS TAG IS TOMATCH THE ZONE AND CONTROLLER ASSOCIATED WITH THE VALVE'S OPERATION.

15. ALL WIRE CONNECTIONS SHALL BE MADE WITH 3M DIRECT BURY DBR-6 WIRECONNECTORS. IRRIGATION CONTRACTOR TO ENSURE THAT THE SAME PERSON BERESPONSIBLE FOR MAKING ALL WIRE CONNECTIONS TO ENSURE CONSISTENCYACROSS THE ENTIRE PROJECT.

16. GROUNDING RODS SHALL BE PLACED EVERY 500 LINEAL FEET ALONG THE ROUTINGOF ALL CONTROL WIRING. ELECTRICAL COMPONENTS SHALL BE GROUNDED TO 5ΩOR LESS ACROSS THE ENTIRE IRRIGATION SYSTEM.

17. CONTRACTOR SHALL PERFORM THE FOLLOWING:A. VISIT SITE AND VERIFY EXISTING GRADES, CONSTRUCTION AND CONDITIONS.B. NOTIFY PLAYING FIELD DESIGNER OF DISCREPANCIES BETWEEN PLAN AND

FIELD CONDITIONS.C. RESTORE CONTRACTOR DAMAGED EXISTING WORK TO THE SATISFACTION OF

THE PLAYING FIELD DESIGNER WITHOUT COST TO THE OWNER.D. BE SATISFIED THAT THE PLAN CAN BE CONSTRUCTED, FUNCTIONAL AND

COMPLETE.

19. CONTRACTOR TO PROVIDE THE FOLLOWING COMPONENTS TO THE OWNER'SREPRESENTATIVE PRIOR TO THE COMPLETION OF THE PROJECT:A. TWO OPERATING KEYS FOR EACH TYPE OF MANUALLY OPERATED VALVES.B. TWO OF EACH SERVICING WRENCH OR TOOL NEEDED FOR COMPLETE

ACCESS, ADJUSTMENT, AND REPAIR OF ALL SPRINKLERSAND EMITTERS.

C. SHOP DRAWINGS INDICATING THE LOCATIONS OF EACH DECODER ANDGROUNDING RODS, WITH AS BUILT OHM READINGS.

20. ALL EQUIPMENT SHALL BE MAINTAINED WHILE UNDER CONSTRUCTION.MAINTENANCE INCLUDES: WATER SCHEDULING, REPLACEMENT OF DEFECTIVE ORDAMAGED EQUIPMENT, ADJUSTMENT AND RE-ADJUSTMENT OF HEADS AND OTHEREQUIPMENT.

21. CONTRACTOR TO ENSURE THE FOLLOWING:A. LINES AND VALVES ARE TO BE PLACED WITHIN TURF AREAS AND WITHIN

PROJECT LIMITS. THESE PLANS ARE SCHEMATIC. CONTRACTOR SHALL SIZE ALLPIPE.

B. 100% COVERAGE OF IRRIGATION SYSTEM TO THE ENTIRE PLAYING FIELD AREAPRIOR TO SUBMITTING A BID.

23. INSTALL TWO (2) SPARE #14-1 AWG CONTROL WIRES FOR EACH UNUSED STATIONAND ONE SPARE #12-1 AWG COMMON WIRE FROM THE RESPECTIVE CONTROLLERTO HIS LOCATION FOR USE AS SPARE WIRES IN EACH REMOTE CONTROL VALVE BOXALONG THE ENTIRE WIRE ROUTING FOR THIS CONTROLLER. SEAL WIRE ENDS WATERTIGHT AND CONTAIN WITHIN VALVE BOX AT THIS LOCATION.

24. SHOULD FIELD ADJUSTMENTS BE MADE TO THE SITE PLAN, IRRIGATION CONTRACTORSHALL MAKE ANY NECESSARY ADJUSTMENTS TO THE IRRIGATION SYSTEM TO ENSUREPROPER FUNCTIONALITY. PLAYING FIELD DESIGNER IS TO BE NOTIFIED OF ANY ANDALL CHANGES MADE TO THE IRRIGATION SYSTEM, PRIOR TO INSTALLATION OF SAIDCHANGES.

25. ALL PLAYING FIELD IRRIGATION HEADS AND QUICK COUPLERS SHALL BE PLACED 12"FROM THE TURF EDGE. NO HEADS SHALL BE PLACED OUTSIDE OF TURF AREAS UNLESSOTHERWISE INDICATED. THE TOPS OF ALL IRRIGATION HEADS SHALL BE PLACED 1/2"BELOW FINISHED GRADE.

26. BALL VALVES ARE TO BE PLACED AT EACH REMOTE CONTROL VALVE TO ALLOWFOR THE SHUT OFF OF AN INDIVIDUAL ZONE, WHILE MAINTAINING THEFUNCTIONALITY OF THE REST OF THE IRRIGATION SYSTEM.

PLAYING FIELD IRRIGATION NOTES

C QUICK COUPLER VALVE INSTALLSECTION VIEW 1" = 1'-0" B REMOTE CONTROL VALVE INSTALL

SECTION VIEW 1" = 1'-0"

TORO 220 BRASS VALVETORO 220 BRASS VALVETORO 220 BRASS VALVETORO 220 BRASS VALVETORO 220 BRASS VALVE

I-40-04-SS

3"

2 1/2"