peugeot of t300 (t code) key programmer

10
APM107 CONTENTS PAGE SPECIAL FUNCTIONS APPLICATIONS CONNECTOR LOCATIONS GENERAL OPERATION 1.1 2.1 3.1 4.1 Version 2.0 12/01 APPLICATIONS MANUAL PEUGEOT IMMOBILISER

Upload: andy-yang

Post on 17-Aug-2015

91 views

Category:

Documents


12 download

TRANSCRIPT

Page 1: Peugeot of t300 (t code) key programmer

APM107

CONTENTS PAGE

SPECIAL FUNCTIONS

APPLICATIONS

CONNECTOR LOCATIONS

GENERAL OPERATION

1.1

2.1

3.1

4.1

Version 2.0 12/01

APPLICATIONS MANUAL PEUGEOT IMMOBILISER

Page 2: Peugeot of t300 (t code) key programmer

1.1

APPLICATIONS

VEHICLE YEAR SYSTEM CABLE

106 1997 ON IMMO 1 ADC110

206 1997 ON CPH ADC110

206 1997 ON BSI

306 1997 ON IMMO 1 ADC110

306 1997 ON CPH ADC110

307 2001 ON BSI ADC110

406 97-99 IMMO1 ADC100 + ADC120

NEW 406 99 ON CPH ADC110

406 COUPE 97 ON CPH ADC110

607 2001 ON BSI ADC110

806 1997 ON CPH ADC110

EXPERT 1997 ON CPH ADC110

PARTNER 1997 ON IMMO 1 ADC110

PARTNER 1997 ON BSI ADC110

RANCH 1997 ON IMMO 1 ADC110

Page 3: Peugeot of t300 (t code) key programmer

2.1

CONNECTOR LOCATIONS

206 : ADC110

306 : ADC110

106 : ADC110

Page 4: Peugeot of t300 (t code) key programmer

2.2

CONNECTOR LOCATIONS

406 : ADC100 + ADC120

NEW 406 : ADC110

307 : ADC110

Page 5: Peugeot of t300 (t code) key programmer

3.1

GENERAL OPERATION

INTRODUCTION The Peugeot Immobiliser systems are made up of 3 different types. They all perform vari-ous functions, and it is important to understand the basic configuration and the types of systems fitted. IMM– STANDARD IMMOBILISER This system was the first transponder system fitted to the Peugeot range of vehicles, after the keypad system was phased out. The system is a basic electronic control unit which consists of immobiliser unit, and transponder aerial to pick up the transponder signal code. This system is similar to the GM immobiliser system, and is programmed and diagnosed in much the same way. CPH—PASSENGER COMPARTMENT PROTECTION CONTROL UNIT The next generation of Immobiliser and alarm system produced the CPH system which controls a number of additional components which further enhances the vehicle protec-tion system. These include central door locking, ultrasonic passenger sensors to name a few. This system is programmed in much the same way, but offers additional functionality on live data and actuators functions. BSI—BODY SYSTEMS INTERFACE This is the latest system, and the alarm and immobiliser have now been incorporated into the body control unit, which controls all body units, including wipers, indicators, lights, doors, windows, locks, boot, service interval, horn, etc. Again, with all the BSI because the immobiliser is part of a complicated system there are many more functions included, on actuators, special functions and live data.

Page 6: Peugeot of t300 (t code) key programmer

4.1

SPECIAL FUNCTIONS

PROGRAMMING KEYS—IMMOBILISER 1 SYSTEM

PROGRAM KEYS

DIAGNOSTIC MENU

PRESS ENTER KEY

SECURITY CODE _ _ _ _

SECURITY CODE X 4 Y T IS THIS CORRECT OK=ENTER CLEAR=BACK

ECU IDENTIFICATION FAULT CODES LIVE DATA ACTUATORS SPECIAL FUNCTIONS

DIAGNOSTIC MENU

PRESS ENTER KEY

Select SPECIAL FUNCTIONS from the Diagnostic Menu using the UP and DOWN arrows. Then press the ENTER key. NOTE : ENSURE ALL DOORS AL CLOSED WHEN KEY PROGRAM-MING IS BEING PERFORMED. Using the UP and DOWn keys select the PROGRAM KEYS option To enter the security code use the fol-lowing procedure :- Press to elect Number & Letter Press To Erase the previous selec-tion Press To ENTER selection. Press To Finish PIN selection.

WARNING : WHEN PROGRAMMING KEYS, THE SYSTEM AUTOMATICALLY ERASES THE PLIP KEYS AT THE SAME TIME. BEFORE PROCEEDING WITH KEY PROGRAMMING, ENSURE YOU HAVE THE PLIP KEY PROGRAMMING PROCEDURE.

Page 7: Peugeot of t300 (t code) key programmer

4.2

SPECIAL FUNCTIONS

Cont’d

If incorrect code is entered the screen will display as shown. NOTE : If the code is entered 3 time incorrectly, then the ECU will lock ac-cess for 15 minutes. If Access code is correct, ENTER the number of keys to program. NOTE : Max 4 keys can be added. Follow on screen instruction for pro-gramming the keys. After switching IGNTION OFF remove the key and repeat procedure for addi-tional keys.

INCORRECT ACCESS CODE

PRESS ENTER KEY

PROGRAMMING KEYS TOTAL KEYS REQUIRED : 2

PRESS ENTER KEY

SWITCH IGNITION ON IGNITION STATUS OFF

SWITCH IGNITION OFF IGNITION STATUS ON

Page 8: Peugeot of t300 (t code) key programmer

4.3

SPECIAL FUNCTIONS

PROGRAMMING KEYS—BSi MODULE

PROGRAM KEYS

DIAGNOSTIC MENU

PRESS ENTER KEY

SECURITY CODE _ _ _ _

SECURITY CODE X 4 Y T IS THIS CORRECT OK=ENTER CLEAR=BACK

ECU IDENTIFICATION FAULT CODES LIVE DATA ACTUATORS SPECIAL FUNCTIONS

DIAGNOSTIC MENU

PRESS ENTER KEY

Select SPECIAL FUNCTIONS from the Diagnostic Menu using the UP and DOWN arrows. Then press the ENTER key. NOTE : ENSURE ALL DOORS AL CLOSED WHEN KEY PROGRAM-MING IS BEING PERFORMED. Using the UP and DOWn keys select the PROGRAM KEYS option To enter the security code use the fol-lowing procedure :- Press to elect Number & Letter Press To Erase the previous selec-tion Press To ENTER selection. Press To Finish PIN selection. NOTE : AFTER PROGRAMMING CLEAR FAULT CODES AND LOCK VEHICLE FOR 10 MINUTES BEFORE TRYING THE KEY OR PLIP.

WARNING : WHEN PROGRAMMING KEYS, THE SYSTEM AUTOMATICALLY ERASES THE PLIP KEYS AT THE SAME TIME. BEFORE PROCEEDING WITH KEY PROGRAMMING, ENSURE YOU HAVE THE PLIP KEY PROGRAMMING PROCEDURE.

Page 9: Peugeot of t300 (t code) key programmer

4.4

SPECIAL FUNCTIONS

Cont’d

If Access code is correct, ENTER the number of keys to program. NOTE : Max 4 keys can be added. Follow on screen instruction for pro-gramming the keys.

TRYING TO COMMUNICATE

PRESS ENTER KEY

SWITCH IGNITION OFF IGNITION STATUS ON

PRESS ENTER KEY

ERASING KEYS PROGRAMMING KEYS

SWITCH IGNITION ON

SWITCH IGNITION OFF

REMOVE KEY FROM IGNITION INSERT NEXT KEY

SWITCH IGNITION ON IGNITION STATUS OFF

Page 10: Peugeot of t300 (t code) key programmer

4.5

SPECIAL FUNCTIONS

Cont’d

NOTE : AFTER PROGRAMMING CLEAR FAULT CODES AND LOCK VEHICLE FOR 10 MINUTES BEFORE TRYING THE KEY OR PLIP.

TRYING TO COMMUNICATE

PRESS ENTER KEY

PRESS BACK TO EXIT PRESS ENTER TO PROGRAM NEXT KEY

PRESS ENTER KEY