pet food express 1330 n. moorpark rd. … express thousand oaks/addendum 1.pdf · 1 x 4 recessed...

4

Upload: vanxuyen

Post on 10-Apr-2018

216 views

Category:

Documents


1 download

TRANSCRIPT

SEAL/SIGNATURE

DRAWING DESCRIPTION

SEAL/SIGNATURE

SCALE

Plo

t D

ate

: J

ul 0

1, 2

01

6 - 1

:0

4p

m P

lo

tte

d b

y: c

yru

s F

ile

na

me

: to

00

.d

wg

ISSUEDATE

McCall Design Group

550 Kearny Street, Suite 950

San Francisco, CA 94108

tel 415.288.8150

fax 415.288.8181

www.mccalldesign.com

SHEET NUMBER

21

50

54

PE

T F

OO

D E

XP

RE

SS

13

30

N

. M

OO

RP

AR

K R

D.

TH

OU

SA

ND

O

AK

S, C

A. 9

13

60

FIL

E N

UM

BE

R:

MINOR APPLICATION12/15/15

CHECK SET02/15/16

PLANING REV.04/04/16

PERMIT05/31/16

BID/CONST.06/27/16

10

-

PLUMBING CALCULATIONS

TOTAL OCCUPANCY

N

PET FOOD EXPRESS1. PROJECT NAME: 2. PROJECT DESCRIPTION:

CODE REVIEW INFORMATION

BUILDING & STRUCTURAL:

1330 N. MOORPARK RD.THOUSAND OAKS, CA. 91360

3. PROJECT LOCATION:

4. TENANT NAME:

PAD BUILDING AND TENANT IMPROVEMENT

PET FOOD EXPRESS

5. LANDLORD: BEAUCHAMP FAMILY LLC.

6. TENANT'S ARCHITECT: McCALL DESIGN GROUP

7. GROSS AREA (E) 5,688 SF (N) 7,981 SF

8. CONSTRUCTION TYPE: V-N SPRINKLED

9. OCCUPANCY TYPE: M

APPLICABLE CODES: ALL WORK DONE UNDER THIS CONTRACT SHALLCOMPLY WITH THE PROVISIONS OF THE SPECIFICATIONS, DRAWINGS &CONSTRUCTION CRITERIA OF THE LANDLORD, AND SHALL SATISFY ALLAPPLICABLE CODES, ORDINANCES, AND REGULATIONS OF ALL GOVERNINGBODIES INVOLVED. ANY MODIFICATIONS TO THE CONTRACT WORKREQUIRED BY SUCH AUTHORITIES SHALL BE PERFORMED BY THE TENANT'SCONTRACTOR. ALL PERMITS AND LICENSES NECESSARY FOR THE EXECUTIONOF THE WORK SHALL BE SECURED AND PAID FOR BY THE TENANT'SCONTRACTOR(S).

10. OCCUPANCY CALCULATIONS:

11. GOVERNING CODES / GUIDELINES:

SPRINKLED

1 PROVIDED

173'-0"

ENERGY CONSERVATION:

LOAD OCCUPANTSAREAUSEFLOOR

MIN. EXIT STAIRWIDTH

occupancy x 0.3occupancy x 0.2WIDTHREQ.

MIN. EXIT DOORPRVD

EXITSFLOOR

EGRESS REQUIREMENTS

1ST FLR.

OFFICE

1ST FLR.

RESTROOMS

TOTAL

2 46.2" 69.3"

6,694

101

58

7,981

2

2013 CBC WITH

2013 T-24 ENERGY STANDARDS2013 CMCMECHANICAL:

ELECTRICAL:PLUMBING:FIRE PROTECTION:ACCESSIBILITY:

12. SPRINKLER SYSTEM:

13. ACCESSIBLE TOILETS:

14. MAX. TRAVEL DIST. TO EXIT:

PET FOOD EXPRESS1330 N. MOORPARK RD.

THOUSAND OAKS, CA 91360

1. WRITTEN DIMENSIONS TAKE PRECEDENCE. DO NOT SCALE THECONSTRUCTION DRAWINGS

2. GC TO VERIFY FIELD CONDITIONS AND ALL BUILDING DIMENSIONS INFIELD BEFORE PROCEEDING WITH WORK. IN THE EVENT OF ADISCREPANCY, NOTIFY THE ARCHITECT IMMEDIATELY FOR RESOLUTIONBEFORE PROCEEDING WITH THE WORK.

3. THE GENERAL CONTRACTOR SHALL COORDINATE ALL PORTIONS OFTHE WORK AS DESCRIBED IN THE CONTRACT DOCUMENTS.

4. DIMENSIONS ARE TO THE CENTERLINE OF STRUCTURAL GRID OR TOFACE OF FINISH UNLESS OTHERWISE INDICATED.

5. CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING THECONSTRUCTION SITE CLEAN AND FREE OF DEBRIS AT ALL TIMES DURINGCONSTRUCTION. DEBRIS TO BE REMOVED DAILY.

6. GENERAL CONTRACTOR SHALL NOTIFY OWNER AND ARCHITECT OFANY DISCREPANCIES IN DOCUMENTS BEFORE PROCEEDING WITHWORK.

7. PROVIDE A VENTURA COUNTY FIRE DEPARTMENT APPROVEDAUTOMATIC SPRINKLER SYSTEM THROUGHOUT THE STRUCTURE.APPLICANT MUST VERIFY WITH THE WATER PURVEYOR IFMODIFICATIONS TO THE WATER METER OR OTHER MODIFICATIONS TOTHE WATER SUPPLY SYSTEM ARE REQUIRED, PRIOR TO THE INSTALLATIONOF THE AUTOMATIC SPRINKLER SYSTEM.

8. 8 FT. HIGH STORAGE RACKS SHOULD BE ACCOMPANIED WITHSTRUCTURAL DESIGN AND ANCHORED.

9. PERIODIC SPECIAL INSPECTION IS REQUIRED DURING THE ANCHORINGOR STORAGE RACKS 8 FT. OR GREATER IN HEIGHT IN STRUCTURESASSIGNED TO SEISMIC DESIGN CATEGORY D. CBC 1705A.11.8

SALES

STORAGE

IT / ELECT.

975

71

2013 CEC2013 CPC2013 CFC2013 CBC / 2010 ADA STANDARDS

CONSTRUCTION OF NEW ONE STORE CORE AND SHELL AND TENANTIMPROVEMENT TO SPACE PET FOOD EXPRESS.THE NEW STRUCTURE WILL CONSIST OF A CONCRETE SLAB ON GRADEAND WOOD FRAMED BUILDING SHELL, WITH EXTERIOR CEMENT PLASTER,ALUMINUM WINDOW/GLAZING SYSTEM AND SINGLE PLY ROOF ANDCONCRETE ROOF TILE. THE WORK WILL ALSO INCLUDE INSTALLATION OFNEW MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS.ASSOCIATED CIVIL AND LANDSCAPING IS UNDER SEPARATE PERMIT.

USE

PROVIDE FIRE EXTINGUISHERS W/ ULLABEL & RATING OF NOT LESS THAN2A10BC W/I 75 FT TRAVEL DISTANCE TOALL PORTIONS OF SPACE

15. FIRE EXTINGUISHERS:

DELTA

ARCHITECT

OWNER / PROJECT MANAGER

ELECTRICAL ENGINEER

CONTACT: CAROL DAVISPET FOOD EXPRESS500 85th AVENUEOAKLAND, CA 94621T: 510.924.3318| F: [email protected]

CONTACT: CYRUS AMANI-TALESHIMcCALL DESIGN GROUP550 KEARNY STREET, SUITE 950SAN FRANCISCO, CA 94108T: 415.288.8150 | F: [email protected]

MP ENGINEERCONTACT: JEFF ELMENDORFELMENDORF & ASSOCIATES INC.630 FRONT ST.KLAMATH FALLS, OR. 97601T: 541.882.4353 | F:[email protected]

CONTACT: JIM PUGAUP LIGHTING ELECTRICAL3130 TWITCHELL ISLAND ROADWEST SACRAMENTO, CA 95691T: 916.371.3202 | F:[email protected]

STRUCTURAL ENGINEER

8

-

CODE DATA

30

AREA LOAD OCCUPANTS

WATER CLOSETS

RETAIL/OFFICE

STORG./UTILT./ELEC.

6,795

1,128

TOTAL

200

5000

34

1

7,923 35

13

-

GENERAL NOTES

11

-

SCOPE OF WORK14

-

VICINITY PLAN

PET FOOD EXPRESS1330 N. MOORPARK RD.

PLUMBING

ELECTRICAL

MECHANICAL

100

-300

300

232

1

40

2

224

LANDLORD CONTACTCONTACT: MARK LARSONBEAUCHAMP FAMILY LLC.10700 SANTA MONICA BLVD. #215LOS ANGELES, CA. 90025T: [email protected]

M1.1 MECHANICAL SCHEDULES AND DETAILSM2.1 MECHANICAL PLANM2.2 MECHANICAL ROOF PLANM3.1 MECHANICAL SPECIFICATIONM3.2 REFRIGERATION DRAWING

E1.0 ONE-LINE & NOTE & SYMBOLS LISTE2.0 POWER & SIGNAL PLANE2.1 ELECTRICAL DETAILSE3.0 LIGHTING PLANE3.1 LIGHTING FIXTURE SCHEDULEE4.0 ROOF POWER PLANE5.0 ELECTRICAL SPECIFICATIONSE5.1 ELECTRICAL SPECIFICATIONS

P1.1 PLUMBING SCHEDULES AND DETAILSP1.2 PLUMBING SCHEDULES AND DETAILSP2.1 PLUMBING WASTE AND VENT PLANP2.2 PLUMBING WATER AND GAS PIPING PLANP2.3 PLUMBING ROOF PLANP3.1 PLUMBING SPECIFICATION

677-0-300-035

STRUCTURALS0.0 MATERIAL NOTES AND SPECIFICATIONSS0.1 GENERAL NOTESS.02 TYPICAL CONCRETE DETAILSS.03 TYPICAL FRAMING DETAILSS.04 TYPICAL FRAMING DETAILSS0.5 TYPICAL FRAMING DETAILSS1.0 FOUNDATION PLANS1.1 CONCRETE CURB PLANS1.2 CEILING FRAMING PLANS2.0 LOW ROOF FRAMING PLANS2.1 MANSARD ROOF FRAMING PLANS3.0 FOUNDATION DETAILSS3.1 DETAILSS3.2 DETAILSS4.0 DETAILS

2013 CA GREEN BUILDING STANDARDS

SPECIAL INSPECTIONS:

SPECIAL INSPECTIONS REQUIRED FOR HILTI-KWIK BOLT TZ (ESR-1917) PERCBC 1705.1.1 AND TABLE 1705.3.

CPC SECTION 422.2 Separate Facilities, Exception 3:IN BUSINESSES AND MERCANTILE OCCUPANCIES WITH ATOTAL OCCUPANT LOAD OF 50 OR LESS INCLUDINGCUSTOMERS AND EMPLOYEES, ONE TOILET FACILITY,DESIGNED FOR USE BY NO MORE THAN ONE PERSON ATA TIME, SHALL BE PERMITTED FOR USE BY BOTH SEXES.

5

-

PROJECT DIRECTORY1

-

DRAWING INDEX

FACTOR

FACTOR

1

ARCHITECTURAL

COVER SHEET

N.T.S.

A0.0

CITY OF THOUSAND OAKS AMEND.

7

-

-

CONTACT: FRANCIS FRANCOSIERRA ENGINEERING GROUP39812 MISSION BLVD. SUITE 100FREMONT, CA. 94539T: [email protected]

A0.0 COVER SHEETA0.0A CALGREEN CHECK LISTA0.0B CALGREEN CHECK LISTA0.01 ENVELOPE COMPLIANCEA0.02 ENERGY COMPLIANCEA0.03 ENERGY COMPLIANCEA0.04 ENERGY COMPLIANCEA0.05 ENERGY COMPLIANCEA0.06 ENERGY COMPLIANCEA0.1 SCHEDULESA0.1A SCHEDULESA0.2 GENERAL NOTES, RESPONSIBILITY MATRIXA0.3 WALL TYPEA0.4 ACCESSIBILITY COMPLIANCEA0.5 SITE PLANA0.6 EGRESS PLANA1.1 FLOOR PLANA1.1A ENLARGED FLOOR PLANA1.2 RACKING PLANA1.3 FLOOR FINISH PLANA2.1 REFLECTED CEILING PLANA3.1 ROOF PLANA4.1 EXTERIOR ELEVATIONA4.2 EXTERIOR ELEVATIONA4.3 BUILDING SECTIONSA4.4 BUILDING SECTIONSA4.5 WALL SECTIONS AND DETAILSA4.6 WALL SECTIONS AND DETAILSA4.7 WALL SECTIONS AND DETAILSA4.8 TRASH ENCLOSURE AND TRELLIS DETAILSA4.9 TRASH ENCLOSURE AND TRELLIS DETAILSA6.1 INTERIOR ELEVATIONSA6.2 INTERIOR ELEVATIONSA6.3 INTERIOR ELEVATIONSA6.4 INTERIOR ELEVATIONSA7.1 WALL & CEILING DETAILSA7.2 INTERIOR DETAILSA7.3 EXTERIOR DETAILSA7.4 EXTERIOR DETAILSA7.5 EXTERIOR DETAILSA7.6 ROOF DETAILSA8.1 PET WASH DETAILSA8.2 PET WASH DETAILSA8.4 CASHWRAP DETAIL;SA8.5 RACKING DETAILSA9.1 MERCHANDISING SIGN PLANA9.2 MERCHANDISING SIGN DETAILSA9.3 MERCHANDISING SIGN DETAILS

16. APN#:

CIVIL ENGINEER CONTACT: DAX HOFF, PE, LEED AP, QSDDAX CONSULTING, INC.23679 CALABASAS RD., # 995CALABASAS, CA. 91302T: [email protected]

LANDSCAPE ARCHITECTCONTACT: RICHARD W. CAMPBELL, ASLA, BSLALANDSCAPE ARCHITECT AND OAK TREE SPECIALISTP.O. BOX 6192THOUSAND OAKS, CA. 91359T: [email protected]

DEFERRED SUBMITTAL; PLANS SHALL BE SUBMITTED UNDER SEPARATEPERMIT TO FIRE PLAN CHECK FOR THE FOLLOWING:

A- FIRE SERVICE UNDERGROUNDB- FIRE SPRINKLER SYSTEMC- FIRE ALARM SYSTEM

UTILITY 82 300 1

ADDENDUM 107/01/16

A

A

3.

2.

1.

4.

8.

5.

9.

6.

7.

10.

8' FLUORESCENT FIXTURE PENDANT MTD AT +13'-0" AFFBRILLIANT LIGHTING GST232PINUNV WITH4-GE F32T8/SPEC41/EC0

A1

A1E

A2

6" APERTURE LED RECESSED DOWNLIGHTHALO PD6-12-ED010-PDM6-83B

8' FLUORESCENT HIGHBAY, BAFFLED FIXTURE(CABLE MOUNTED W/ STEMS AT POWER FEEDS)TEXAS FLUORESCENT FHBL-2-328-M20-DMV WITHDIMMING BALLAST WITH 4-GE F32T8/SPEC41/EC0

C

CE

C1

4' SURFACE MOUNTED FLUORESCENT FIXTURE WITHWRAPAROUND ACRYLIC REFRACTOR BASKETBRILLIANT NBW232PINUNV WITH2-GE F32T8/SPEC41/EC0

G

GA

2 X 4 RECESSED FLUORESCENT FIXTURECOLUMBIA STE24-232G-MP0-U-FK24 WITH2-GE F32T8/SPEC41/EC0

K

KE

1 x 4 RECESSED FLUORESCENT WALL WASHEREPL 232-T8-WW-AKTB WITH2-GE F32T8/SPEC41/EC0

L

MB VERTICAL ROUND ACCENT, MTD AT +12'-0" AFFMB-L441LDIM-W-32P

4' FLUORESCENT STRIP FIXTUREMETALUX SSF-132-UNV-EB-81WITH 1-GE F32T8/SPEC41/ECO

Q

EXIT SIGN WITH INTERNALLY LIT 6" GREEN LETTERS ON WHTEBODY WITH 90 MINUTES BATTERY BACK-UP(VERIFY WALL OR CEILING MOUNT)BRILLIANT KA-U-1-G-W-W-EM

X

MUSIC SPEAKER; COORDINATE MOUNTING AND WIRINGREQUIREMENTS WITH MUSIC SYSTEM VENDOR; GC TOPROVIDE CONDUIT AS REQUIRED TO AVOID EXPOSEDWIRING (6 SPEAKERS PER TYPICAL STORE)

SECURITY SYSTEM CAMERA; COORDINATE MOUNTINGAND WIRING REQUIREMENTS WITH SECURITY SYSTEMVENDOR; GC TO PROVIDE CONDUIT AS REQUIRED TOAVOID EXPOSED WIRING

SECURITY SYSTEM MOTION SENSOR; COORDINATEMOUNTING AND WIRING REQUIREMENTS WITH SECURITYSYSTEM VENDOR; GC TO PROVIDE CONDUIT AS REQUIREDTO AVOID EXPOSED WIRING

SECURITY SYSTEM DOOR CONTACT; COORDINATEMOUNTING AND WIRING REQUIREMENTS WITH SECURITYSYSTEM VENDOR; GC TO PROVIDE CONDUIT AS REQUIREDTO AVOID EXPOSED WIRING

24" x 30" ACCESS PANEL (PAINT TO MATCH CEILING)COORDINATE LOCATION WITH EQUIPMENT TO BEACCESSED

M12" PENDANT WITH LED LAMP AT CASHWRAPCONTECH CGM1215AFCS

LED TAPE - APPLIED TO INSIDE FACES OF MULLIONS(TOP / SIDE / BOTTOM)WAC LIGHTINGINVISILED PRO 2 - 24V HIGH OUTPUT LED TAPE LIGHT

LED

4' FLUORESCENT FIXTURE PENDANT MTD AT +13'-0" AFFBRILLIANT LIGHTING GS232PINUNV WITH2-GE F32T8/SPEC41/EC0

4' FLUORESCENT FIXTURE PENDANT WITH 90 MINUTESBATTERY BACK-UP MTD AT +13'-0" AFFBRILLIANT LIGHTING GS232PINUNVEM WITH2-GE F32T8/SPEC41/EC0

4' SURFACE MOUNTED FLUORESCENT FIXTURE WITH 90MINUTES BATTERY BACK-UP AND WRAPAROUND ACRYLICREFRACTOR BASKETBRILLIANT NBW232PINUNVEM WITH2-GE F32T8/SPEC41/EC0

2 X 4 RECESSED FLUORESCENT FIXTURE WITH 90 MINUTESBATTERY BACK-UPCOLUMBIA STE24-232G-MP0-U-EL-FK24 WITH2-GE F32T8/SPEC41/EC0

M18" PENDANT WITH FROSTED ACRYLIC LENS AT BAKERYCONTECH CGF8-42-A-FC-S-CG8FAL WITHONE (1)- 42W COMPACT FLUORESCENT LAMP

SYMBOL DESCRIPTION

EXTERIOR RECESSED DOWNLIGHTSPECTRUM LIGHTINGSG8H-2-42-EX-BH27-AR8620-RBBF-PG-WL WITHTWO (2)-42W COMPACT FLUORESCENT LAMPS

Y

CUSTOM CABLE SUSPENDED LIGHT FIXTUREMTD. TEN (10) - 29W LED LAMPS, MTD. AT7'-6" AFF

M

WALL MOUNTED EXTERIOR FLOOD LIGHTSSI WP15P150QL WITH 150W METAL HALIDE LAMPT

11. 4' FLUORESCENT HIGHBAY, BAFFLED FIXTURE(CABLE MOUNTED W/ STEMS AT POWER FEEDS)TEXAS FLUORESCENT FHBL-2-324-M20-DMV WITHDIMMING BALLAST WITH 2-GE F32T4/SPEC41/EC0

8' FLUORESCENT HIGHBAY, BAFFLED FIXTURE(CABLE MOUNTED W/ STEMS AT POWER FEEDS)TEXAS FLUORESCENT FHBL-2-328-M20-DMV-EM7 WITHDIMMING BALLAST WITH 4-GE F32T8/SPEC41/EC0

KEY NOTES 1NO SCALE

REFLECTED CEILING PLAN 21/8" = 1'-0"

LEGEND 13-

GENERAL NOTES 14-

SYMBOL DESCRIPTION ANNUNCIATOR RECEIVER ABOVE DOOR OR CEILING, SEEELECTRICAL DRAWINGS

PROVIDE DOOR BELL, SEE ELECTRICAL DRAWINGS

POWER OUTLET FOR "OPEN" SIGN, ABOVE WINDOW

ANNUNCIATOR TRANSMITTER ABOVE THE DOOR

CABLE TRAY ABOVE GRID CEILING

FLUORESCENT LIGHT FIXTURES MTD TO BACK F.O. GRAPHICS BELOW;SEE 11/A1.2

SKYLIGHT ABOVE

EXTERIOR SIGNAGE, SEE ELEVATION AND ELECTRICAL DRAWINGS

HVAC DIFFUSERS, SEE MECHANICAL DRAWINGS

GYP. BD. SOFFIT AT 7'-5" A.F.F.

CENTER SUSPENDED SIGNAGE ABOVE EDGE OF BACKWRAP 8'-0"AFF TO BOTTOM, ALL CEILING HUNG SIGNS SHALL BE HUNGMINIMUM OF 18" BELOW SPRINKLER DEFLECTORSPAINT UNDERSIDE OF ROOF, BEAMS AND JOISTS P-1. TYPICAL INSALES AREA

NOT USED

LINE OF FOLDED ACCESS LADDER ABOVE. 30"X83" PRECISION SUPERSIMPLE W/ DEEP ANGLE FRAME. GC. TO VERIFY FLOOR TO ROOFHEIGHT AND COORDINATE WITH MANUFACTURER, PROVIDESUPPORT AS NEEDED, LOCATE LADDER TO CLEAR ALL FLOOR ANDCEILING FIXTURES, SEE STRUCTURAL DRAWINGS

ROOF DRAIN AND OVER FLOW, COORDINATE WITH MECHANICALDUCT. SEE PLUMBING DRAWINGS

EMERGENCY EGRESS EXIT LIGHT

24" X 30" ACCESS PANEL TO ATTIC SPACE ABOVE

9

A7.1

SIM.

100 CAT ADOPTION

EXISTING PARTITION TO REMAIN

(N) PARTITION, WALL TYPE TAG (REFER TO WALL TYPE SCHEDULE)

DETAIL/ENLARGED PLAN REFERENCE

ROOM NAME & NUMBER9'-0" A.F.F. GYP. BD. CEILING HEIGHT & TYPE TAG

TAG

CEILING FIXTURE SCHEDULE 10-

BRILLIANT 2X2 LED DIRECT / INDIRECT REFLECTOR-RECESSEDG2

(E) RELOCATED CANOPY DOWNLIGHTZ2

S EXTERIOR SURFACE MOUNTED WALL SCONE, TBD

12.

13.

13.

C1

30"

60"

60"

48"

P P

WH-

2

C C C C C C

C C C C C C

C C C C C

C C

C C

C C C C C C C C

C

C1

K

L LL

LL

L

KE

K

K

P

P P

QQQQQQ

QQ

QQ

QQ

Q

Q Q Q Q Q Q

Q

G

Ts

ss

s

s s

s s

ss

BB

CE

WH-1sss

s

CC

P

P

P

B

B

B

B

B

B

B

B

B

C P CC

Q

Q

P

C

K

P

CE

CE

CCC

CECE

CECE

CE

CECE

C1C1

C1

C1

GE

GE

T T

XE

C

C1

C1C101 SALES

06 RESTROOM

04 RECEIVING

07 OFFICE

08 TRASH AREA

05 IT/ELEC.

03 UTILITY02 PET WASHOPEN

OPEN

9'-0" GYP.BD.

9'-0" GYP.BD.

10'-6" A.F.F. ACT_2

OPEN

EXTERIOR EMERGENCY EXIT LIGHTXE

8'-4

1/2

"9'

-0"

9'-0

"9'

-0"

9'-0

"9'

-0"

9'-0

"8'

-4 1

/2"

6'-10 3/4"EQ.

6'-10 3/4"EQ.

ALIGN

4'-0" 8'-0"

ALIGN

EQ.

EQ.

EQ.

EQ.

EQ. EQ.

EQ.

EQ.

EQ.

EQ.

EQ.

EQ.

EQ.

EQ.

EQ. A

EQ. A

EQ.

48" TYP.

EQ. EQ.

4'-0"TYP.

EQ.

EQ.

EQ.

EQ. 2'-6"

EQ.

EQ.

EQ. EQ.

2'-0"2'-0"

4'-0

"

EQ. EQ.

4'-0"

4'-0

"

ALIGN

CL

11

4'-0

"4'

-0"

4'-0" 4'-0"

1

CLCL

CL

16'-0"

17'-9 1/2"35'-7 1/4"35'-7 1/4"17'-9 1/2"

9'-1

"8'

-0"

5'-1

1 7/

8"4'

-0 1

/4"

8'-0

"

2

2

3

4

1

5

6TYP.

6TYP.

6TYP.

8

8

10

10

12TYP.

13TYP.

147 7

7

15

15

7

4'-0"

EQ. EQ. EQ. EQ. EQ. EQ. EQ. EQ.

EQ. EQ. EQ. EQ.

EQ.

16

17

17

17

XE

s

9'-0" GYP.BD.

SEAL/SIGNATURE

DRAWING DESCRIPTION

SEAL/SIGNATURE

SCALE

Plo

t D

ate

: J

ul 0

1, 2

01

6 - 1

:0

5p

m P

lo

tte

d b

y: c

yru

s F

ile

na

me

: to

21

.d

wg

ISSUEDATE

McCall Design Group

550 Kearny Street, Suite 950

San Francisco, CA 94108

tel 415.288.8150

fax 415.288.8181

www.mccalldesign.com

SHEET NUMBER

21

50

54

PE

T F

OO

D E

XP

RE

SS

13

30

N

. M

OO

RP

AR

K R

D.

TH

OU

SA

ND

O

AK

S, C

A. 9

13

60

FIL

E N

UM

BE

R:

MINOR APPLICATION12/15/15

CHECK SET02/15/16

PLANING REV.04/04/16

PERMIT05/31/16

BID/CONST.06/27/16

REFLECTED CEILING PLAN

AS NOTED

A2.1

ADDENDUM 107/01/16

A

A

INTERIOR ELEVATION 21/4" = 1'-0"

INTERIOR ELEVATION 11/4" = 1'-0"

8'-0

"TO

B.O

. SO

FFIT

5'-0

"C

UR

VED

SO

FFIT

FREEZERS

GWB RECESSEDP_

MY-MUTT-30"MY-MUTT-30" MY-MUTT-30"MY-MUTT-30"

MY-MUTT-30"

BASERB_1

IN NICHEINSIDE WALLS AND BACKWALL OF FREEZER CAVITYTO BE PAINTED P_5, TYP.

7'-5

"5'

-7"

5

A7.1

GWB SOFFITP_

CORNERGUARDS

CORNERGUARDS

12A6.4

GWB WALLP_

GWB SOFFITP_

GWB RECESSEDP_

PROVIDE DUPLEX ON THE POST FOR "OPEN" SIGN,PROVIDE CONDUIT ALONG THE POST AND PAINT TOMATCH STOREFRONT SYSTEM SEE ELECTRICALDRAWINGS

ANNUNCIATORTRANSMITTER

ALUMINUM STOREFRONT SYSTEM WITHPOWER SLIDING DOORS, SEE DOOR

SCHEDULE

GWB WALLP_

8'-0

"TO

B.O

. SO

FFIT

GWB SOFFITP_

GWB RECESSEDP_

UTILITY AREA

BASERB_1

BASERB_1

BASERB_1

BASERB_1

12'-6

"TO

B.O

. FIX

TUR

E

12'-6

"TO

B.O

. FIX

TUR

E

SUSPENDEDACT CEILING

SUSPENDEDACT CEILING

ROOF DRAIN AND OVERFLOW

13'-1

"TO

B.O

. DU

CT

MECHANICAL DUCT

13'-1

"TO

B.O

. DU

CT

MECHANICAL DUCT

PET WASH AREA

MY-MUTT-30"MY-MUTT-30"MY-MUTT-30"

PRECISION SUPER FOLDING ACCESS LADDERBEYOND. COORDINATE LOCATION WITHFLOOR AND CEILING FIXTURES. SEE STRUCTURALDRAWINGS

MECHANICAL DUCT

SEAL/SIGNATURE

DRAWING DESCRIPTION

SEAL/SIGNATURE

SCALE

Plo

t D

ate

: J

ul 0

1, 2

01

6 - 1

:0

5p

m P

lo

tte

d b

y: c

yru

s F

ile

na

me

: to

61

.d

wg

ISSUEDATE

McCall Design Group

550 Kearny Street, Suite 950

San Francisco, CA 94108

tel 415.288.8150

fax 415.288.8181

www.mccalldesign.com

SHEET NUMBER

21

50

54

PE

T F

OO

D E

XP

RE

SS

13

30

N

. M

OO

RP

AR

K R

D.

TH

OU

SA

ND

O

AK

S, C

A. 9

13

60

FIL

E N

UM

BE

R:

MINOR APPLICATION12/15/15

CHECK SET02/15/16

PLANING REV.04/04/16

PERMIT05/31/16

BID/CONST.06/27/16

INTERIOR ELEVATIONS

AS NOTED

A6.1

ADDENDUM 107/01/16

A

A