the new radon gas sensor - radiansa consulting 0 1000 2000 3000 4000 5000 0 8 16 24 32 40 48 56...
TRANSCRIPT
TM
0
1000
2000
3000
4000
5000
0 8 16 24 32 40 48 56
Rado
n Co
ncen
trat
ion
[Bq/
m3 ]
Time [h]
RS001000021
Ref. monitor 1
Ref. monitor 2
(test carried out at the National Institute of Ionizing Radiation Metrology, INMRI-ENEA)
®
Free to breathe
www.rsens.it
Via Vignolese 905, 41125 Modena (MO) - ITALY tel +39 059 2056262 | fax +39 059 2056262 | email [email protected]
RStone™ is the new innovative Radon gas sensor, which combines professional performance and extreme ease of use. Portable, small-size, battery-powered and easily programmable, to make measuring indoor
Radon simple and immediate.
the new Radon gas sensor
Linear response over the measuring range (up to 5 MBq/m3)
Measurements scheduling through display or PC*
Data export to a PC and report generation*
Rechargeable battery (15 days of battery life during measurement)
6% accuracy after 48 hours (at 150 Bq/m3)
Remote monitoring of sensors connected in a network**
*requires RKey™ USB device, sold separately**requires the implementation of a sensor network based on the RCloud™ system
TM
the new Radon gas sensor
RSens srl | Via Vignolese 905/b - 41125 Modena (MO) - ITALY | Via Segantini 23 – 38122, Trento (TN) – ITALY VAT N° 02197570225 | phone +39 059 2056262 | fax +39 059 205 6262 | mail [email protected] | web www.rsens.it
TECHNICAL SHEET
General External supply voltage input 100-240 VAC, 50-60 Hz
RStone voltage input 10 V, 1400 mA
Temperature (storage and working) 0°C – 40°C
Relative humidity (storage and working) 0% – 95% RH
Battery life 15 days typ.
Storage capacity 100 measurements of 1 year each
Dimensions 16x16x11 cm
Weight 1.8 kg
Radon concentration measurement Measuring range 0 Bq/m3 … 5 MBq/m3
Sensitivity 5 count/h @ 100 Bq/m3
Uncertainty 20% after 4 h @ 150 Bq/m3 or after 1 h @ 500 Bq/m3 (coverage factor k=1)
Blank count rate (null Radon concentration) 0.05 count/h (1.2 Bq/m3)
Update rate 60 minutes
Alert threshold 200 Bq/m3 (ref. Eur. Recc. 90/143/Euratom)
Other data Temperature full-scale range -40°C … +125°C
Temperature resolution 0.04°C
Temperature accuracy ± 0.3°C typ.
Pressure full-scale range 50 kPa … 115 kPa
Pressure resolution 0.15 kPa typ.
Pressure accuracy ± 1 kPa typ.
Relative humidity full-scale range 0% RH … 100% RH
Relative humidity resolution 0.7% RH
Relative humidity accuracy ± 2% RH typ.
Radio module Frequency 2433 MHz nominal
Data rate 250 kbaud max.
Channel bandwidth 200 kHz
Maximum output power 0 dBm
Modulation MSK
Battery Type Rechargeable Li-Ion
Voltage 7.2 V
Capacity 10 Ah
Charge mode CC-CV
Charge current 1100 mA max.
Charge time 10 h typ.