2700 Blankenbaker Pkwy, Suite 150, Louisville, KY 40299 | 1-800-223-9436 | www.honeywell.com Model NetAXS-123 Access Control Panel See manual 800-05779, Rev A for installation instructions. 800-06789-A HOLD B HOLD A IN4 (TAMPER B) OUT4 (BZR) IN3 (TAMPER A) +12 V GND D1 D0 OUT2 (LED) IN1 (REX) COM IN2 (STS) NO/NC DRY C RETURN NO/NC DRY C RETURN DC OUT A B COM +24VDC IN IN5 COM IN6 (PWR FAIL) NO 1 10 LED PWR RUN LED RD1 LED LEDs Max Relay Contact Ratings Self Wetted 12VDC: 0.5 A (500mA) Dry Contact: 3 Amps HOLD B HOLD A BZR IN11 (TAMPER A) IN12 (TAMPER B) +12 V GND D1 D0 OUT8 (LED) IN9 (REX) COM IN10 (STS) NO/NC DRY C RETURN NO/NC DRY C RETURN NO 1 10 Tamper Switch Socket Ethernet Connection PoE/Data Power Input Terminals USB Connection OUT 1 OUT 3 OUT 7 OUT 9 For Future Use RS485_1 RS485_2 DIP SWITCH INFO: 1 thru 5 - ON to specify RS485 address 6 - ON Gateway, OFF Downstream 7 - ON Forces Ethernet IP address to 192.168.1.150 OFF User-defined IP address 8 and 9 - Both ON: Line terminated Both OFF: Line un-terminated 10 - Reserved +12V NC EXT NO +12V NC EXT NO Normally Closed (NC) Normally Open (NO) NOTE: Factory defaults are 12VDC and Normally Open (NO) Return Dry C NO/NC Locking Device Return Dry C NO/NC Locking Device EXT Power Supply (+30VDC Max) + DC DC OR +12VDC Configuration External Power Supply Configuration } +12V NC EXT NO +12V NC EXT NO 12VDC External (EXT) Power RUN LED

Upload: truongdat

Post on 06-Mar-2018

217 views

Category:

Documents


2 download

TRANSCRIPT

2700

Bla

nken

bake

r Pkw

y, S

uite

150

, Lou

isvi

lle, K

Y 40

299

| 1-8

00-2

23-9

436

| ww

w.h

oney

wel

l.com

Model NetAXS-123Access Control PanelSee manual 800-05779, Rev A for installation instructions. 800-06789-A

HO

LD B

HO

LD A

IN4 (TA

MPER B)

OU

T4 (BZR)

IN3 (TA

MPER A

)

+12 V

GN

D

D1

D0

OU

T2 (LED)

IN1 (REX)

COM

IN2 (STS)

NO

/NC

DRY C

RETURN

NO

/NC

DRY C

RETURN

DC OUT

A

B

COM

+24VDC IN

IN5

COM

IN6 (PWR FAIL)

NO

110

LEDPWR

RUN

LED

RD1

LED

LEDs

Max Relay Contact Ratings Self Wetted 12VDC: 0.5 A (500mA) Dry Contact: 3 Amps

HO

LD B

HO

LD A

BZR

IN11 (TA

MPER A

)

IN12 (TA

MPER B)

+12 V

GN

DD1

D0

OU

T8 (LED)

IN9 (REX)

COM

IN10 (STS)

NO

/NC

DRY C

RETURN

NO

/NC

DRY C

RETURN

NO

1

10

Tamper Sw

itch Socket

Ethernet ConnectionPoE/Data

Power Input Terminals

USB Connection

OUT 1 OUT 3

OUT 7 OUT 9

For Future Use

RS485_1 RS485_2

DIP SWITCH INFO:1 thru 5 - ON to specify RS485 address6 - ON Gateway, OFF Downstream7 - ON Forces Ethernet IP address to 192.168.1.150 OFF User-de�ned IP address

8 and 9 - Both ON: Line terminated Both OFF: Line un-terminated10 - Reserved

+12V NC

EXT NO

+12V NC

EXT NO

Normally Closed (NC) Normally Open (NO)

NOTE: Factory defaults are 12VDC and Normally Open (NO)

ReturnD

ry CN

O/N

C

Locking Device

ReturnD

ry CN

O/N

C

Locking Device

EXT Power Supply (+30VDC Max)

+ DC

DC

OR

+12VDC Con�guration

External Power Supply Con�guration

}+12V NC

EXT NO

+12V NC

EXT NO

12VDC External (EXT) Power