pck ss278 (jpg version) - alpine home air products contained ac 10 seer.pdf · 3 product...
TRANSCRIPT
SS-278D 3/04
PRODUCT SPECIFICATIONS
www.goodmanmfg.com
Self-Contained Packaged Air Conditioner
The PCK self-contained, packaged air conditioner allows for side-by-side ground-level or rooftop application and is approved
for manufactured and modular homes.
Standard Features• Convenient access panels• Two-speed evaporator blower motor; low-speed for
normal or low-static application, high-speed for high-static application in manufactured homes
• Quiet operating top grille condenser discharge• Copper tube, aluminum fin coil• Totally enclosed, permanently lubricated condenser
fan motor• Hermetically sealed compressor with internal
relief valve• Fully charged R-22 system• Liquid line filter drier• High-efficiency performance• Bottom pan rails elevate the unit above the slab
Cabinet Construction• Powder-paint finish with 500-hour salt spray
approval• Fully insulated air handling compartment• When properly anchored, meets the 2001 Florida
Building Code unit integrity requirements for hurricane-type winds
PCK SERIES10 SEER
Accessories• Roof curb• Downflow Plenum (includes filter rack)• Manual fresh air damper (to be used with Downflow
Plenum)• Economizer (to be used with Downflow Plenum)• Square to Round Duct Converter for Round Duct
applications (Horizontal and Downflow)• Elbow and Flashing Downflow Kit• Room Thermostat (CHT18-60)• Outdoor Thermostat (OT18-60)• Heat Kit from 5 to 20 kW with plug-in connection
Accessory Heat Kit Features• Controlled by sequencers for better temperature
control (single-phase units only)• Control circuitry arranged to readily permit staging
(HK10,15, 20-1 only)• Primary and secondary limit protection• Rust-resistant nickel chromium heating elements• Factory-installed circuit breakers on certain models
(see Electrical Data)
2 to 5 TonCooling Capacity: 23,200 - 58,000 BTUH
PRODUCT SPECIFICATIONS
2
PCK024-1A PCK030-1A PCK036-1A PCK036-3B PCK042-1ATotal Cooling-BTUH
Sens. Cooling-BTUHSEER (1)EERa (2)Sound Rating(bels)
23,20016,80010.09.08.0
28,40020,60010.09.08.0
35,00025,60010.09.08.0
35,00025,60010.09.08.0
42,00032,00010.09.08.4
Indoor BlowerTypeSize - D x WMotor H.P.
DD9 x 61/5
DD9 x 61/3
DD9 x 61/3
DD9 x 61/3
DD9 x 81/3
Evaporator CoilFace Area (ft2)Fin/In.No. of Rows
3.33142
3.33142
3.33143
3.33143
5.25143
Outdoor FanFan Dia. (In.)Motor H.P.
181/6
181/6
181/6
181/6
221/4
Condenser CoilFace Area (ft2)Fin/In.No. of Rows
12.1191
12.1191
12.1191
12.1191
14.7191
ElectricalPhVoltsCompr. RLACompr. LRAIndoor Blw FLAOutdoor Blw FLA
Min. Circuit Amp.M.O.P. (3)
1208/230
9.856.01.71.015.020
1208/230
13.875.02.61.020.930
1208/230
16.296.02.61.023.940
3208/230
10.375.02.61.016.520
1208/230
17.1105.02.61.625.640
Net Weight 240 245 265 265 335Shipping Weight 255 260 280 280 350
(1) Certified per ARI 210(2) BTU/Watt @ 80/67 °F inside - 95 °F outside air(3) M.O.P. (Maximum Overcurrent Protection)Note - May use fuses or HACR type Circuit Breakers of the same size as noted
Specifications
3
PRODUCT SPECIFICATIONS
PCK048-1A PCK048-3A PCK060-1 PCK060-3 PCK060-4Total Cooling-BTUH
Sens. Cooling-BTUHSEER (1)EERa (2)Sound Rating(bels)
46,00035,80010.09.08.4
46,00035,80010.09.08.4
58,00043,50010.09.08.4
58,00043,50010.09.08.4
58,00043,50010.09.08.4
Indoor BlowerTypeSize - D x WMotor H.P.
DD10 x 81/2
DD10 x 81/2
DD10 x 83/4
DD10 x 83/4
DD10 x 83/4
Evaporator CoilFace Area (ft2)Fin/In.No. of Rows
5.75144
5.75144
6.22144
6.22144
6.22144
Outdoor FanFan Dia. (In.)Motor H.P.
221/4
221/4
221/3
221/3
221/3
Condenser CoilFace Area (ft2)Fin/In.No. of Rows
14.7191
14.7191
16.2191
16.2191
16.2191
ElectricalPhVoltsCompr. RLACompr. LRAIndoor Blw FLAOutdoor Blw FLA
Min. Circuit Amp.M.O.P. (3)
1208/230
18.3102.03.61.628.240
3208/230
12.691.03.61.621.030
1208/230
25.0170.05.12.538.960
3208/230
15.5124.05.12.527.040
14607.559.62.21.212.820
Net Weight 340 340 350 350 350Shipping Weight 365 365 375 375 375
(1) Certified per ARI 210(2) BTU/Watt @ 80/67 °F inside - 95 °F outside air(3) M.O.P. (Maximum Overcurrent Protection)Note - May use fuses or HACR type Circuit Breakers of the same size as noted
Specifications (cont.)
PRODUCT SPECIFICATIONS
4
Dimensions
5
PRODUCT SPECIFICATIONS
E.S.P (In. of H2O)
MODEL SPEED VOLTS 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
PCK024-1
LOW230 CFM
WATTS1100400
1080390
1055380
1020370
975355
950330
900305
855285
--
--
208 CFMWATTS
1060375
1040365
1005335
950330
920320
890305
845285
795260
--
--
HIGH230 CFM
WATTS1250470
1240465
1200450
1150435
1070420
1035400
995370
945345
890320
835290
208 CFMWATTS
1225440
1220435
1175420
1125410
1045395
1010375
960345
900320
835295
805265
PCK030-1A
LOW230 CFM
WATTS1150320
1120310
1075300
1005290
955275
870255
770240
--
--
--
208 CFMWATTS
1110355
1080285
1055255
945250
900240
8100230
--
--
--
--
MED230 CFM
WATTS1275385
1265380
1210360
1135350
1070335
985310
855290
--
--
--
208 CFMWATTS
1250355
1245340
1185335
1110330
1045300
9602285
820265
--
--
--
HIGH230 CFM
WATTS1345435
1335430
1275415
1210400
1135390
1035375
925355
785330
--
--
208 CFMWATTS
1310405
1315400
1250385
1175375
1110365
1010350
890330
740305
--
--
PCK036-1A
LOW230 CFM
WATTS1100315
1070305
1025295
965285
905270
820250
720235
--
--
--
208 CFMWATTS
1060350
1030280
1005250
895245
850235
760225
--
--
--
--
MED230 CFM
WATTS1225380
1215375
1160355
1085345
1020330
935305
805285
--
--
--
208 CFMWATTS
1200350
1195335
1135330
1060325
995295
910280
770260
--
--
--
HIGH230 CFM
WATTS1295430
1285425
1225410
1150395
1085385
985370
875350
735325
--
--
208 CFMWATTS
1260400
1265395
1200380
1125370
1060360
960345
840325
690300
--
--
PCK042-X
LOW230 CFM
WATTS1390460
1375440
1365425
1355420
1330410
1280380
--
--
--
--
208 CFMWATTS
1320430
1310415
1300400
1285395
1260385
--
--
--
--
--
HIGH230 CFM
WATTS1725550
1630520
1590510
1560500
1520480
1400430
1315410
--
--
--
208 CFMWATTS
1640525
1550495
1515485
1485475
1445455
1330410
1250380
--
--
--
PCK048-X
LOW230 CFM
WATTS1760725
1730690
1685670
1635640
1580600
1490565
--
--
--
--
208 CFMWATTS
1640700
1610665
1600650
1580625
1490565
--
--
--
--
--
HIGH230 CFM
WATTS2010870
1990840
1960810
1880765
1795710
1695670
1595635
--
--
--
208 CFMWATTS
1910825
1895790
1865770
1790730
1710680
1615640
1520605
--
--
--
PCK060-X
LOW230 CFM
WATTS2160910
2125865
2085830
2025800
1970765
--
--
--
--
--
208 CFMWATTS
2055820
2010780
1985755
1890740
1870730
--
--
--
--
--
HIGH230 CFM
WATTS25401115
24701070
23101020
2280985
2220945
2095895
--
--
--
--
208 CFMWATTS
24251055
23501020
2200985
2150935
2120905
1995855
--
--
--
--
NOTES:1. Data shown is dry coil. Wet coil pressure drop is approx.
0.1” H2O, for 2 row indoor coil; 0.2” H
2O, for 3 row indoor coil; and 0.3” H
2O, for 4 row indoor coil.
2. Data shown does not include filter pressure drop, approx. 0.08” H2O.
3. ALL MODELS SHOULD RUN NO LESS THAN 350 CFM / TON, USE HIGHER SPEED TAP OR NEXT SIZE LARGER BLOWER ASM., SEE REPAIR PARTS LIST.
Evaporator Blower Specifications
PRODUCT SPECIFICATIONS
6
Expanded RatingsPCK024-1A
INDOORAIR
CONDENSER AIR TEMPERATURE75 85 95 105 115
SCFM WB TOTALMBTUH
SENSMBTUH
WATTSKWH
TOTALMBTUH
SENSMBTUH
WATTSKWH
TOTALMBTUH
SENSMBTUH
WATTSKWH
TOTALMBTUH
SENSMBTUH
WATTSKWH
TOTALMBTUH
SENSMBTUH
WATTSKWH
657
72 26.9 12.6 2.42 25.8 12.1 2.55 24.4 11.6 2.66 23.0 11.1 2.78 21.6 10.6 2.9167 24.6 15.6 2.27 23.4 15.1 2.37 22.3 14.6 2.50 20.9 14.1 2.63 19.5 14.1 2.7662 22.7 18.5 2.11 21.6 18.0 2.24 21.0 17.5 2.37 20.4 17.0 2.50 19.3 16.3 2.6057 21.8 20.0 2.06 20.9 19.2 2.19 20.0 18.3 2.32 18.8 17.3 2.47 17.9 16.3 2.58
773
72 28.1 13.9 2.50 26.7 13.4 2.60 25.3 12.9 2.73 23.9 12.6 2.86 22.3 11.9 2.9967 25.8 17.8 2.35 24.6 17.3 2.45 23.2 16.8 2.58 21.8 16.3 2.71 20.4 15.8 2.8462 23.9 21.3 2.22 22.7 20.7 2.32 21.6 19.8 2.45 20.6 18.8 2.58 19.5 17.8 2.7357 23.7 21.7 2.19 22.5 20.8 2.32 21.6 19.8 2.45 20.6 18.8 2.58 19.5 17.8 2.73
889
72 28.8 15.1 2.55 27.4 14.6 2.66 26.0 14.1 2.78 24.4 13.6 2.91 23.0 13.3 3.0467 26.7 19.7 2.40 25.3 19.3 2.50 23.9 18.8 2.63 22.5 18.1 2.76 21.1 17.6 2.8962 25.1 23.0 2.29 24.1 22.0 2.42 22.7 21.0 2.55 21.8 20.0 2.68 20.4 18.8 2.8457 25.1 23.0 2.29 24.1 22.0 2.42 22.7 21.0 2.55 21.8 20.0 2.68 20.4 18.8 2.84
PCK030-1A
Sensible heat capacities shown are based on 80 °F DB entering air at the evaporator coil. For sensible heat capacities at other than 80 °F DB, deduct 84 BTUH per 100 CFM of evaporator coil air for each degree below 80 °F, or add 84 BTUH per 100 CFM of evaporator coil air per degree above 80 °F.CAPACITIES AT 95 °F OUTDOOR, 75 °F DB AND 63 °F WB INDOORTOTAL MBTUH 21.9 SENSIBLE MBTUH 16.0 LATENT MBTUH 5.9
INDOORAIR
CONDENSER AIR TEMPERATURE75 85 95 105 115
SCFM WB TOTALMBTUH
SENSMBTUH
WATTSKWH
TOTALMBTUH
SENSMBTUH
WATTSKWH
TOTALMBTUH
SENSMBTUH
WATTSKWH
TOTALMBTUH
SENSMBTUH
WATTSKWH
TOTALMBTUH
SENSMBTUH
WATTSKWH
805 72 32.9 15.5 2.97 31.5 14.8 3.12 29.8 14.2 3.25 28.1 13.6 3.41 26.4 13.0 3.5767 30.1 19.2 2.78 28.7 18.5 2.90 27.3 17.9 3.06 25.6 17.3 3.22 23.9 17.3 3.3862 27.8 22.7 2.59 26.4 22.0 2.75 25.7 21.4 2.90 25.0 20.8 3.06 23.6 20.0 3.1957 26.7 24.5 2.52 25.6 23.5 2.68 24.4 22.5 2.84 23.0 21.2 3.03 21.9 20.0 3.16
947 72 34.4 17.1 3.06 32.7 16.5 3.19 31.0 15.9 3.34 29.3 15.5 3.50 27.3 14.6 3.6667 31.5 21.8 2.87 30.1 21.2 3.00 28.4 20.6 3.16 26.7 20.0 3.31 25.0 19.4 3.4762 29.3 26.2 2.71 27.8 25.3 2.84 26.4 24.3 3.00 25.3 23.1 3.16 23.9 21.8 3.3457 29.0 26.6 2.68 27.5 25.5 2.84 26.4 24.3 3.00 25.3 23.1 3.16 23.9 21.8 3.34
1089 72 35.2 18.5 3.12 33.5 17.9 3.25 31.8 17.3 3.41 29.8 16.7 3.57 28.1 16.3 3.7267 32.7 24.1 2.93 31.0 23.7 3.06 29.3 23.1 3.22 27.5 22.2 3.38 25.8 21.6 3.5362 30.7 28.2 2.81 29.5 27.0 2.97 27.8 25.8 3.12 26.7 24.5 3.28 25.0 23.1 3.4757 30.7 28.2 2.81 29.5 27.0 2.97 27.8 25.8 3.12 26.7 24.5 3.28 25.0 23.1 3.47
Sensible heat capacities shown are based on 80 °F DB entering air at the evaporator coil. For sensible heat capacities at other than 80 °F DB, deduct 84 BTUH per 100 CFM of evaporator coil air for each degree below 80 °F, or add 84 BTUH per 100 CFM of evaporator coil air per degree above 80 °F.CAPACITIES AT 95 °F OUTDOOR, 75 °F DB AND 63 °F WB INDOORTOTAL MBTUH 26.8 SENSIBLE MBTUH 19.6 LATENT MBTUH 7.2
7
PRODUCT SPECIFICATIONS
PCK036-1A & -3A
INDOORAIR
CONDENSER AIR TEMPERATURE75 85 95 105 115
SCFM WB TOTALMBTUH
SENSMBTUH
WATTSKWH
TOTALMBTUH
SENSMBTUH
WATTSKWH
TOTALMBTUH
SENSMBTUH
WATTSKWH
TOTALMBTUH
SENSMBTUH
WATTSKWH
TOTALMBTUH
SENSMBTUH
WATTSKWH
992
72 40.6 19.2 3.66 38.9 18.4 3.85 36.8 17.7 4.01 34.7 16.9 4.20 32.6 16.1 4.3967 37.1 23.8 3.42 35.4 23.0 3.58 33.6 22.3 3.77 31.5 21.5 3.97 29.4 21.5 4.1662 34.3 28.2 3.19 32.6 27.4 3.38 31.7 26.6 3.58 30.8 25.9 3.77 29.1 24.8 3.9357 32.9 30.5 3.11 31.5 29.2 3.31 30.1 27.9 3.50 28.4 26.4 3.73 27.0 24.8 3.89
1167
72 42.4 21.2 3.77 40.3 20.5 3.93 38.2 19.7 4.12 36.1 19.2 4.32 33.6 18.2 4.5167 38.9 27.1 3.54 37.1 26.4 3.69 35.0 25.6 3.89 32.9 24.8 4.08 30.8 24.1 4.2862 36.1 32.5 3.34 34.3 31.5 3.50 32.6 30.2 3.69 31.2 28.7 3.89 29.4 27.1 4.1257 35.7 33.0 3.31 34.0 31.7 3.50 32.6 30.2 3.69 31.2 28.7 3.89 29.4 27.1 4.12
1342
72 43.4 23.0 3.85 41.3 22.3 4.01 39.2 21.5 4.20 36.8 20.7 4.39 34.7 20.2 4.5967 40.3 30.0 3.62 38.2 29.4 3.77 36.1 28.7 3.97 34.0 27.6 4.16 31.9 26.9 4.3662 37.8 35.1 3.46 36.4 33.5 3.66 34.3 32.0 3.85 32.9 30.5 4.04 30.8 28.7 4.2857 37.8 35.1 3.46 36.4 33.5 3.66 34.3 32.0 3.85 32.9 30.5 4.04 30.8 28.7 4.28
Sensible heat capacities shown are based on 80 °F DB entering air at the evaporator coil. For sensible heat capacities at other than 80 °F DB, deduct 84 BTUH per 100 CFM of evaporator coil air for each degree below 80 °F, or add 84 BTUH per 100 CFM of evaporator coil air per degree above 80 °F.CAPACITIES AT 95 °F OUTDOOR, 75 °F DB AND 63 °F WB INDOORTOTAL MBTUH 33.0 SENSIBLE MBTUH 24.4 LATENT MBTUH 8.7
PCK042-1A
INDOORAIR
CONDENSER AIR TEMPERATURE75 85 95 105 115
SCFM WB TOTALMBTUH
SENSMBTUH
WATTSKWH
TOTALMBTUH
SENSMBTUH
WATTSKWH
TOTALMBTUH
SENSMBTUH
WATTSKWH
TOTALMBTUH
SENSMBTUH
WATTSKWH
TOTALMBTUH
SENSMBTUH
WATTSKWH
1190
72 48.7 24.0 4.39 46.6 23.0 4.62 44.1 22.1 4.81 41.6 21.1 5.04 39.1 20.2 5.2767 44.5 29.8 4.11 42.4 28.8 4.29 40.3 27.8 4.53 37.8 26.9 4.76 35.3 26.9 4.9962 41.2 35.2 3.83 39.1 34.2 4.06 38.0 33.3 4.29 37.0 32.3 4.53 34.9 31.0 4.7157 39.5 38.1 3.73 37.8 36.5 3.97 36.1 34.9 4.20 34.0 33.0 4.48 32.3 31.0 4.67
1400
72 50.8 26.6 4.53 48.3 25.6 4.71 45.8 24.6 4.95 43.3 24.0 5.18 40.3 22.7 5.4167 46.6 33.9 4.25 44.5 33.0 4.43 42.0 32.0 4.67 39.5 31.0 4.90 37.0 30.1 5.1362 43.3 40.6 4.01 41.2 39.4 4.20 39.1 37.8 4.43 37.4 35.8 4.67 35.3 33.9 4.9557 42.8 41.3 3.97 40.7 39.7 4.20 39.1 37.8 4.43 37.4 35.8 4.67 35.3 33.9 4.95
1610
72 52.1 28.8 4.62 49.6 27.8 4.81 47.0 26.9 5.04 44.1 25.9 5.27 41.6 25.3 5.5167 48.3 37.4 4.34 45.8 36.8 4.53 43.3 35.8 4.76 40.7 34.6 4.99 38.2 33.6 5.2362 45.4 43.8 4.15 43.7 41.9 4.39 41.2 40.0 4.62 39.5 38.1 4.85 37.0 35.8 5.1357 45.4 43.8 4.15 43.7 41.9 4.39 41.2 40.0 4.62 39.5 38.1 4.85 37.0 35.8 5.13
Sensible heat capacities shown are based on 80 °F DB entering air at the evaporator coil. For sensible heat capacities at other than 80 °F DB, deduct 84 BTUH per 100 CFM of evaporator coil air for each degree below 80 °F, or add 84 BTUH per 100 CFM of evaporator coil air per degree above 80 °F.CAPACITIES AT 95 °F OUTDOOR, 75 °F DB AND 63 °F WB INDOORTOTAL MBTUH 39.6 SENSIBLE MBTUH 30.7 LATENT MBTUH 8.9
Expanded Ratings (cont.)
PRODUCT SPECIFICATIONS
8
PCK048-1A & 3A
PCK060-1, 3 & 4
Expanded Ratings (cont.)
INDOORAIR
CONDENSER AIR TEMPERATURE75 85 95 105 115
SCFM WB TOTALMBTUH
SENSMBTUH
WATTSKWH
TOTALMBTUH
SENSMBTUH
WATTSKWH
TOTALMBTUH
SENSMBTUH
WATTSKWH
TOTALMBTUH
SENSMBTUH
WATTSKWH
TOTALMBTUH
SENSMBTUH
WATTSKWH
1303
72 53.4 26.9 4.80 51.1 25.8 5.06 48.3 24.7 5.26 45.5 23.6 5.52 42.8 22.6 5.7867 48.8 33.3 4.50 46.5 32.2 4.70 44.2 31.1 4.96 41.4 30.1 5.21 38.6 30.1 5.4762 45.1 39.4 4.19 42.8 38.3 4.45 41.6 37.2 4.70 40.5 36.2 4.96 38.2 34.7 5.1657 43.2 42.6 4.09 41.4 40.8 4.34 39.6 39.0 4.60 37.3 36.9 4.91 35.4 34.7 5.11
1533
72 55.7 29.7 4.96 52.9 28.6 5.16 50.1 27.6 5.42 47.4 26.9 5.67 44.2 25.4 5.9367 51.1 37.9 4.65 48.8 36.9 4.86 46.0 35.8 5.11 43.2 34.7 5.37 40.5 33.7 5.6262 47.4 45.5 4.40 45.1 44.0 4.60 42.8 42.2 4.86 40.9 40.1 5.11 38.6 37.9 5.4257 46.9 46.2 4.34 44.6 44.4 4.60 42.8 42.2 4.86 40.9 40.1 5.11 38.6 37.9 5.42
1763
72 57.0 32.2 5.06 54.3 31.1 5.26 51.5 30.1 5.52 48.3 29.0 5.78 45.5 28.3 6.0367 52.9 41.9 4.75 50.1 41.2 4.96 47.4 40.1 5.21 44.6 38.7 5.47 41.9 37.6 5.7262 49.7 49.0 4.55 47.8 46.9 4.80 45.1 44.8 5.06 43.2 42.6 5.32 40.5 40.1 5.6257 49.7 49.0 4.55 47.8 46.9 4.80 45.1 44.8 5.06 43.2 42.6 5.32 40.5 40.1 5.62
Sensible heat capacities shown are based on 80 °F DB entering air at the evaporator coil. For sensible heat capacities at other than 80 °F DB, deduct 84 BTUH per 100 CFM of evaporator coil air for each degree below 80 °F, or add 84 BTUH per 100 CFM of evaporator coil air per degree above 80 °F.CAPACITIES AT 95 °F OUTDOOR, 75 °F DB AND 63 °F WB INDOORTOTAL MBTUH 43.4 SENSIBLE MBTUH 34.5 LATENT MBTUH 8.9
INDOORAIR
CONDENSER AIR TEMPERATURE75 85 95 105 115
SCFM WB TOTALMBTUH
SENSMBTUH
WATTSKWH
TOTALMBTUH
SENSMBTUH
WATTSKWH
TOTALMBTUH
SENSMBTUH
WATTSKWH
TOTALMBTUH
SENSMBTUH
WATTSKWH
TOTALMBTUH
SENSMBTUH
WATTSKWH
1643
72 67.3 32.6 6.06 64.4 31.3 6.38 60.9 30.0 6.64 57.4 28.7 6.96 53.9 27.4 7.2867 61.5 40.5 5.67 58.6 39.2 5.93 55.7 37.8 6.25 52.2 36.5 6.57 48.7 36.5 6.9062 56.8 47.9 5.28 53.9 46.5 5.61 52.5 45.2 5.93 51.0 43.9 6.25 48.1 42.2 6.5157 54.5 51.8 5.16 52.2 49.6 5.48 49.9 47.4 5.80 47.0 44.8 6.19 44.7 42.2 6.44
1933
72 70.2 36.1 6.25 66.7 34.8 6.51 63.2 33.5 6.83 59.7 32.6 7.15 55.7 30.9 7.4867 64.4 46.1 5.86 61.5 44.8 6.12 58.0 43.5 6.44 54.5 42.2 6.77 51.0 40.9 7.0962 59.7 55.2 5.54 56.8 53.5 5.80 53.9 51.3 6.12 51.6 48.7 6.44 48.7 46.1 6.8357 59.2 56.1 5.48 56.3 53.9 5.80 53.9 51.3 6.12 51.6 48.7 6.44 48.7 46.1 6.83
2223
72 71.9 39.2 6.38 68.4 37.8 6.64 65.0 36.5 6.96 60.9 35.2 7.28 57.4 34.4 7.6067 66.7 50.9 5.99 63.2 50.0 6.25 59.7 48.7 6.57 56.3 47.0 6.90 52.8 45.7 7.2262 62.6 59.6 5.74 60.3 57.0 6.06 56.8 54.4 6.38 54.5 51.8 6.70 51.0 48.7 7.0957 62.6 59.6 5.74 60.3 57.0 6.06 56.8 54.4 6.38 54.5 51.8 6.70 51.0 48.7 7.09
Sensible heat capacities shown are based on 80 °F DB entering air at the evaporator coil. For sensible heat capacities at other than 80 °F DB, deduct 84 BTUH per 100 CFM of evaporator coil air for each degree below 80 °F, or add 84 BTUH per 100 CFM of evaporator coil air per degree above 80 °F.CAPACITIES AT 95 °F OUTDOOR, 75 °F DB AND 63 °F WB INDOORTOTAL MBTUH 54.8 SENSIBLE MBTUH 41.6 LATENT MBTUH 13.1
9
PRODUCT SPECIFICATIONS
HK 05 - 1
Electrical Designator
1 - 208 / 240 VAC, 1 PH, 50/60 HZ
3 - 208 / 240 VAC, 3 PH, 50/60 HZ
Nominal Capacity
05 - 4.75 KW
10 - 9.5 KW
15 - 14.25 KW
20 - 19.0 KW
Unit Type
HK - Optional Heat Kit
Heat Kit Model Identification
Heat Kit Electrical Data
ModelNo.
NominalK. W.
HeaterAmperage
MinimumAmpacity
Multiple Supply Circuit
MaximumOvercurrentProtection
Min. Ampacityper Circuit
Max. OvercurrentProtection
208/240V
208/240V 1 2 1 2HK05-1* 4.75 17.2/19.8 22/25 30/30HK08-1* 7.00 25.3/29.2 32/37 60/60HK10-1* 9.50 34.4/39.6 43/50 60/60HK10-3 9.50 20.7/23.6 26/30 30/30HK15-1* 14.25 51.5/59.4 65/75 90/90 22/25 43/50 30/30 60/60HK15-3 15.0 31.7/36.2 40/46 50/50HK15-4# 15.0 18.1 23 30HK20-1* 19.0 68.7/79.2 86/99 120/120 43/50 43/50 60/60 60/60HK20-3 19.6 41.4/47.2 52/59 60/60HK20-4# 19.6 23.6 30 30
* - Circuit Breaker ModelsRatings at 208/240 VAC, except where noted# - Ratings at 480 VAC, PH 3
Heat Kit Selection
MODEL PCK024-1 PCK030-1 PCK036-1 PCK036-3 PCK042-1 PCK042-3 PCK048-1 PCK048-3 PCK060-1 PCK060-3 PCK060-4HK50-1 * * * * * * * * * * *HK08-1 * * * * * * * * * * *HK10-X * * * * * * * * * * *HK15-X * * * * * * * * *HK20-X * * * * * * * *
NOTE: X = 1, 3 OR 4 Electrical Designator.
PRODUCT SPECIFICATIONS
10
AccessoriesSMALL MEDIUM LARGE
Roof Curb PCCP-1 PCCP2-3 PCCP2-3Down Flow Plenum PCP-1 PCP2-3 PCP2-3Manual Fresh Air Damper PCMD-1 PCMD2-3 PCMD2-3Economizer - Down Flow PCE-1 PCE2-3 PCE2-3Square To Round Converter (Downfl ow) SQRPC-1 SQRPC2-3 SQRPC2-3Square To Round Converter (Horizontal) SQRPCH-1 SQRPCH-2 SQRPCH-3Elbow & Flashing PCEF-1 PCEF2-3 PCEF2-3Room Thermostat CHT18-60 CHT18-60 CHT18-60
NOTE - Down Flow Plenum includes Filter Rack
KW Correction FactorSupply Voltage 240 230 220 210 208Correction Factor 1.00 0.93 0.85 0.78 0.76
(Multiply the 240 VAC capacity by factors)
Chassis Sizes
SMALL MEDIUM LARGEPC024 PCK042 PCK060PC030 PCK048PC036
11
PRODUCT SPECIFICATIONS
PCK PCK PCK 024 -1
Electrical Designator1 - 208/230 VAC, 1 Ph, 60 Hz3 - 208/230 VAC, 3 Ph, 60 Hz4 - 460 VAC, 3 Ph, 60 Hz
Nominal Capacity024 - 24,000 BTUH030 - 30,000036 - 36,000042 - 42,000048 - 48,000060 - 60,000
Unit TypePCK - Package Cooling(SECOND GENERATION)
ALL UNITS ARE DIRECT DRIVE
Model Identification
PRODUCT SPECIFICATIONS
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations.Copyright © 2003 Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. • Goodman products are made proudly in the USA.
12