SS-278D 3/04 www.goodmanmfg.com Self-Contained Packaged Air Conditioner The PCK self-contained, packaged air conditioner allows for side-by-side ground- level or rooftop application and is approved for manufactured and modular homes. Standard Features Convenient access panels Two-speed evaporator blower motor; low-speed for normal or low-static application, high-speed for high-static application in manufactured homes Quiet operating top grille condenser discharge Copper tube, aluminum fin coil Totally enclosed, permanently lubricated condenser fan motor Hermetically sealed compressor with internal relief valve Fully charged R-22 system Liquid line filter drier High-efficiency performance Bottom pan rails elevate the unit above the slab Cabinet Construction Powder-paint finish with 500-hour salt spray approval Fully insulated air handling compartment When properly anchored, meets the 2001 Florida Building Code unit integrity requirements for hurricane-type winds PCK SERIES 10 SEER Accessories Roof curb Downflow Plenum (includes filter rack) Manual fresh air damper (to be used with Downflow Plenum) Economizer (to be used with Downflow Plenum) Square to Round Duct Converter for Round Duct applications (Horizontal and Downflow) Elbow and Flashing Downflow Kit Room Thermostat (CHT18-60) Outdoor Thermostat (OT18-60) Heat Kit from 5 to 20 kW with plug-in connection Accessory Heat Kit Features Controlled by sequencers for better temperature control (single-phase units only) Control circuitry arranged to readily permit staging (HK10,15, 20-1 only) Primary and secondary limit protection Rust-resistant nickel chromium heating elements Factory-installed circuit breakers on certain models (see Electrical Data) 2 to 5 Ton Cooling Capacity: 23,200 - 58,000 BTUH

Upload: others

Post on 20-Jun-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: pck ss278 (jpg version) - Alpine Home Air Products Contained AC 10 SEER.pdf · 3 PRODUCT SPECIFICATIONS PCK048-1A PCK048-3A PCK060-1 PCK060-3 PCK060-4 Total Cooling-BTUH Sens. Cooling-BTUH

SS-278D 3/04

PRODUCT SPECIFICATIONS

www.goodmanmfg.com

Self-Contained Packaged Air Conditioner

The PCK self-contained, packaged air conditioner allows for side-by-side ground-level or rooftop application and is approved

for manufactured and modular homes.

Standard Features• Convenient access panels• Two-speed evaporator blower motor; low-speed for

normal or low-static application, high-speed for high-static application in manufactured homes

• Quiet operating top grille condenser discharge• Copper tube, aluminum fin coil• Totally enclosed, permanently lubricated condenser

fan motor• Hermetically sealed compressor with internal

relief valve• Fully charged R-22 system• Liquid line filter drier• High-efficiency performance• Bottom pan rails elevate the unit above the slab

Cabinet Construction• Powder-paint finish with 500-hour salt spray

approval• Fully insulated air handling compartment• When properly anchored, meets the 2001 Florida

Building Code unit integrity requirements for hurricane-type winds

PCK SERIES10 SEER

Accessories• Roof curb• Downflow Plenum (includes filter rack)• Manual fresh air damper (to be used with Downflow

Plenum)• Economizer (to be used with Downflow Plenum)• Square to Round Duct Converter for Round Duct

applications (Horizontal and Downflow)• Elbow and Flashing Downflow Kit• Room Thermostat (CHT18-60)• Outdoor Thermostat (OT18-60)• Heat Kit from 5 to 20 kW with plug-in connection

Accessory Heat Kit Features• Controlled by sequencers for better temperature

control (single-phase units only)• Control circuitry arranged to readily permit staging

(HK10,15, 20-1 only)• Primary and secondary limit protection• Rust-resistant nickel chromium heating elements• Factory-installed circuit breakers on certain models

(see Electrical Data)

2 to 5 TonCooling Capacity: 23,200 - 58,000 BTUH

Page 2: pck ss278 (jpg version) - Alpine Home Air Products Contained AC 10 SEER.pdf · 3 PRODUCT SPECIFICATIONS PCK048-1A PCK048-3A PCK060-1 PCK060-3 PCK060-4 Total Cooling-BTUH Sens. Cooling-BTUH

PRODUCT SPECIFICATIONS

2

PCK024-1A PCK030-1A PCK036-1A PCK036-3B PCK042-1ATotal Cooling-BTUH

Sens. Cooling-BTUHSEER (1)EERa (2)Sound Rating(bels)

23,20016,80010.09.08.0

28,40020,60010.09.08.0

35,00025,60010.09.08.0

35,00025,60010.09.08.0

42,00032,00010.09.08.4

Indoor BlowerTypeSize - D x WMotor H.P.

DD9 x 61/5

DD9 x 61/3

DD9 x 61/3

DD9 x 61/3

DD9 x 81/3

Evaporator CoilFace Area (ft2)Fin/In.No. of Rows

3.33142

3.33142

3.33143

3.33143

5.25143

Outdoor FanFan Dia. (In.)Motor H.P.

181/6

181/6

181/6

181/6

221/4

Condenser CoilFace Area (ft2)Fin/In.No. of Rows

12.1191

12.1191

12.1191

12.1191

14.7191

ElectricalPhVoltsCompr. RLACompr. LRAIndoor Blw FLAOutdoor Blw FLA

Min. Circuit Amp.M.O.P. (3)

1208/230

9.856.01.71.015.020

1208/230

13.875.02.61.020.930

1208/230

16.296.02.61.023.940

3208/230

10.375.02.61.016.520

1208/230

17.1105.02.61.625.640

Net Weight 240 245 265 265 335Shipping Weight 255 260 280 280 350

(1) Certified per ARI 210(2) BTU/Watt @ 80/67 °F inside - 95 °F outside air(3) M.O.P. (Maximum Overcurrent Protection)Note - May use fuses or HACR type Circuit Breakers of the same size as noted

Specifications

Page 3: pck ss278 (jpg version) - Alpine Home Air Products Contained AC 10 SEER.pdf · 3 PRODUCT SPECIFICATIONS PCK048-1A PCK048-3A PCK060-1 PCK060-3 PCK060-4 Total Cooling-BTUH Sens. Cooling-BTUH

3

PRODUCT SPECIFICATIONS

PCK048-1A PCK048-3A PCK060-1 PCK060-3 PCK060-4Total Cooling-BTUH

Sens. Cooling-BTUHSEER (1)EERa (2)Sound Rating(bels)

46,00035,80010.09.08.4

46,00035,80010.09.08.4

58,00043,50010.09.08.4

58,00043,50010.09.08.4

58,00043,50010.09.08.4

Indoor BlowerTypeSize - D x WMotor H.P.

DD10 x 81/2

DD10 x 81/2

DD10 x 83/4

DD10 x 83/4

DD10 x 83/4

Evaporator CoilFace Area (ft2)Fin/In.No. of Rows

5.75144

5.75144

6.22144

6.22144

6.22144

Outdoor FanFan Dia. (In.)Motor H.P.

221/4

221/4

221/3

221/3

221/3

Condenser CoilFace Area (ft2)Fin/In.No. of Rows

14.7191

14.7191

16.2191

16.2191

16.2191

ElectricalPhVoltsCompr. RLACompr. LRAIndoor Blw FLAOutdoor Blw FLA

Min. Circuit Amp.M.O.P. (3)

1208/230

18.3102.03.61.628.240

3208/230

12.691.03.61.621.030

1208/230

25.0170.05.12.538.960

3208/230

15.5124.05.12.527.040

14607.559.62.21.212.820

Net Weight 340 340 350 350 350Shipping Weight 365 365 375 375 375

(1) Certified per ARI 210(2) BTU/Watt @ 80/67 °F inside - 95 °F outside air(3) M.O.P. (Maximum Overcurrent Protection)Note - May use fuses or HACR type Circuit Breakers of the same size as noted

Specifications (cont.)

Page 4: pck ss278 (jpg version) - Alpine Home Air Products Contained AC 10 SEER.pdf · 3 PRODUCT SPECIFICATIONS PCK048-1A PCK048-3A PCK060-1 PCK060-3 PCK060-4 Total Cooling-BTUH Sens. Cooling-BTUH

PRODUCT SPECIFICATIONS

4

Dimensions

Page 5: pck ss278 (jpg version) - Alpine Home Air Products Contained AC 10 SEER.pdf · 3 PRODUCT SPECIFICATIONS PCK048-1A PCK048-3A PCK060-1 PCK060-3 PCK060-4 Total Cooling-BTUH Sens. Cooling-BTUH

5

PRODUCT SPECIFICATIONS

E.S.P (In. of H2O)

MODEL SPEED VOLTS 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

PCK024-1

LOW230 CFM

WATTS1100400

1080390

1055380

1020370

975355

950330

900305

855285

--

--

208 CFMWATTS

1060375

1040365

1005335

950330

920320

890305

845285

795260

--

--

HIGH230 CFM

WATTS1250470

1240465

1200450

1150435

1070420

1035400

995370

945345

890320

835290

208 CFMWATTS

1225440

1220435

1175420

1125410

1045395

1010375

960345

900320

835295

805265

PCK030-1A

LOW230 CFM

WATTS1150320

1120310

1075300

1005290

955275

870255

770240

--

--

--

208 CFMWATTS

1110355

1080285

1055255

945250

900240

8100230

--

--

--

--

MED230 CFM

WATTS1275385

1265380

1210360

1135350

1070335

985310

855290

--

--

--

208 CFMWATTS

1250355

1245340

1185335

1110330

1045300

9602285

820265

--

--

--

HIGH230 CFM

WATTS1345435

1335430

1275415

1210400

1135390

1035375

925355

785330

--

--

208 CFMWATTS

1310405

1315400

1250385

1175375

1110365

1010350

890330

740305

--

--

PCK036-1A

LOW230 CFM

WATTS1100315

1070305

1025295

965285

905270

820250

720235

--

--

--

208 CFMWATTS

1060350

1030280

1005250

895245

850235

760225

--

--

--

--

MED230 CFM

WATTS1225380

1215375

1160355

1085345

1020330

935305

805285

--

--

--

208 CFMWATTS

1200350

1195335

1135330

1060325

995295

910280

770260

--

--

--

HIGH230 CFM

WATTS1295430

1285425

1225410

1150395

1085385

985370

875350

735325

--

--

208 CFMWATTS

1260400

1265395

1200380

1125370

1060360

960345

840325

690300

--

--

PCK042-X

LOW230 CFM

WATTS1390460

1375440

1365425

1355420

1330410

1280380

--

--

--

--

208 CFMWATTS

1320430

1310415

1300400

1285395

1260385

--

--

--

--

--

HIGH230 CFM

WATTS1725550

1630520

1590510

1560500

1520480

1400430

1315410

--

--

--

208 CFMWATTS

1640525

1550495

1515485

1485475

1445455

1330410

1250380

--

--

--

PCK048-X

LOW230 CFM

WATTS1760725

1730690

1685670

1635640

1580600

1490565

--

--

--

--

208 CFMWATTS

1640700

1610665

1600650

1580625

1490565

--

--

--

--

--

HIGH230 CFM

WATTS2010870

1990840

1960810

1880765

1795710

1695670

1595635

--

--

--

208 CFMWATTS

1910825

1895790

1865770

1790730

1710680

1615640

1520605

--

--

--

PCK060-X

LOW230 CFM

WATTS2160910

2125865

2085830

2025800

1970765

--

--

--

--

--

208 CFMWATTS

2055820

2010780

1985755

1890740

1870730

--

--

--

--

--

HIGH230 CFM

WATTS25401115

24701070

23101020

2280985

2220945

2095895

--

--

--

--

208 CFMWATTS

24251055

23501020

2200985

2150935

2120905

1995855

--

--

--

--

NOTES:1. Data shown is dry coil. Wet coil pressure drop is approx.

0.1” H2O, for 2 row indoor coil; 0.2” H

2O, for 3 row indoor coil; and 0.3” H

2O, for 4 row indoor coil.

2. Data shown does not include filter pressure drop, approx. 0.08” H2O.

3. ALL MODELS SHOULD RUN NO LESS THAN 350 CFM / TON, USE HIGHER SPEED TAP OR NEXT SIZE LARGER BLOWER ASM., SEE REPAIR PARTS LIST.

Evaporator Blower Specifications

Page 6: pck ss278 (jpg version) - Alpine Home Air Products Contained AC 10 SEER.pdf · 3 PRODUCT SPECIFICATIONS PCK048-1A PCK048-3A PCK060-1 PCK060-3 PCK060-4 Total Cooling-BTUH Sens. Cooling-BTUH

PRODUCT SPECIFICATIONS

6

Expanded RatingsPCK024-1A

INDOORAIR

CONDENSER AIR TEMPERATURE75 85 95 105 115

SCFM WB TOTALMBTUH

SENSMBTUH

WATTSKWH

TOTALMBTUH

SENSMBTUH

WATTSKWH

TOTALMBTUH

SENSMBTUH

WATTSKWH

TOTALMBTUH

SENSMBTUH

WATTSKWH

TOTALMBTUH

SENSMBTUH

WATTSKWH

657

72 26.9 12.6 2.42 25.8 12.1 2.55 24.4 11.6 2.66 23.0 11.1 2.78 21.6 10.6 2.9167 24.6 15.6 2.27 23.4 15.1 2.37 22.3 14.6 2.50 20.9 14.1 2.63 19.5 14.1 2.7662 22.7 18.5 2.11 21.6 18.0 2.24 21.0 17.5 2.37 20.4 17.0 2.50 19.3 16.3 2.6057 21.8 20.0 2.06 20.9 19.2 2.19 20.0 18.3 2.32 18.8 17.3 2.47 17.9 16.3 2.58

773

72 28.1 13.9 2.50 26.7 13.4 2.60 25.3 12.9 2.73 23.9 12.6 2.86 22.3 11.9 2.9967 25.8 17.8 2.35 24.6 17.3 2.45 23.2 16.8 2.58 21.8 16.3 2.71 20.4 15.8 2.8462 23.9 21.3 2.22 22.7 20.7 2.32 21.6 19.8 2.45 20.6 18.8 2.58 19.5 17.8 2.7357 23.7 21.7 2.19 22.5 20.8 2.32 21.6 19.8 2.45 20.6 18.8 2.58 19.5 17.8 2.73

889

72 28.8 15.1 2.55 27.4 14.6 2.66 26.0 14.1 2.78 24.4 13.6 2.91 23.0 13.3 3.0467 26.7 19.7 2.40 25.3 19.3 2.50 23.9 18.8 2.63 22.5 18.1 2.76 21.1 17.6 2.8962 25.1 23.0 2.29 24.1 22.0 2.42 22.7 21.0 2.55 21.8 20.0 2.68 20.4 18.8 2.8457 25.1 23.0 2.29 24.1 22.0 2.42 22.7 21.0 2.55 21.8 20.0 2.68 20.4 18.8 2.84

PCK030-1A

Sensible heat capacities shown are based on 80 °F DB entering air at the evaporator coil. For sensible heat capacities at other than 80 °F DB, deduct 84 BTUH per 100 CFM of evaporator coil air for each degree below 80 °F, or add 84 BTUH per 100 CFM of evaporator coil air per degree above 80 °F.CAPACITIES AT 95 °F OUTDOOR, 75 °F DB AND 63 °F WB INDOORTOTAL MBTUH 21.9 SENSIBLE MBTUH 16.0 LATENT MBTUH 5.9

INDOORAIR

CONDENSER AIR TEMPERATURE75 85 95 105 115

SCFM WB TOTALMBTUH

SENSMBTUH

WATTSKWH

TOTALMBTUH

SENSMBTUH

WATTSKWH

TOTALMBTUH

SENSMBTUH

WATTSKWH

TOTALMBTUH

SENSMBTUH

WATTSKWH

TOTALMBTUH

SENSMBTUH

WATTSKWH

805 72 32.9 15.5 2.97 31.5 14.8 3.12 29.8 14.2 3.25 28.1 13.6 3.41 26.4 13.0 3.5767 30.1 19.2 2.78 28.7 18.5 2.90 27.3 17.9 3.06 25.6 17.3 3.22 23.9 17.3 3.3862 27.8 22.7 2.59 26.4 22.0 2.75 25.7 21.4 2.90 25.0 20.8 3.06 23.6 20.0 3.1957 26.7 24.5 2.52 25.6 23.5 2.68 24.4 22.5 2.84 23.0 21.2 3.03 21.9 20.0 3.16

947 72 34.4 17.1 3.06 32.7 16.5 3.19 31.0 15.9 3.34 29.3 15.5 3.50 27.3 14.6 3.6667 31.5 21.8 2.87 30.1 21.2 3.00 28.4 20.6 3.16 26.7 20.0 3.31 25.0 19.4 3.4762 29.3 26.2 2.71 27.8 25.3 2.84 26.4 24.3 3.00 25.3 23.1 3.16 23.9 21.8 3.3457 29.0 26.6 2.68 27.5 25.5 2.84 26.4 24.3 3.00 25.3 23.1 3.16 23.9 21.8 3.34

1089 72 35.2 18.5 3.12 33.5 17.9 3.25 31.8 17.3 3.41 29.8 16.7 3.57 28.1 16.3 3.7267 32.7 24.1 2.93 31.0 23.7 3.06 29.3 23.1 3.22 27.5 22.2 3.38 25.8 21.6 3.5362 30.7 28.2 2.81 29.5 27.0 2.97 27.8 25.8 3.12 26.7 24.5 3.28 25.0 23.1 3.4757 30.7 28.2 2.81 29.5 27.0 2.97 27.8 25.8 3.12 26.7 24.5 3.28 25.0 23.1 3.47

Sensible heat capacities shown are based on 80 °F DB entering air at the evaporator coil. For sensible heat capacities at other than 80 °F DB, deduct 84 BTUH per 100 CFM of evaporator coil air for each degree below 80 °F, or add 84 BTUH per 100 CFM of evaporator coil air per degree above 80 °F.CAPACITIES AT 95 °F OUTDOOR, 75 °F DB AND 63 °F WB INDOORTOTAL MBTUH 26.8 SENSIBLE MBTUH 19.6 LATENT MBTUH 7.2

Page 7: pck ss278 (jpg version) - Alpine Home Air Products Contained AC 10 SEER.pdf · 3 PRODUCT SPECIFICATIONS PCK048-1A PCK048-3A PCK060-1 PCK060-3 PCK060-4 Total Cooling-BTUH Sens. Cooling-BTUH

7

PRODUCT SPECIFICATIONS

PCK036-1A & -3A

INDOORAIR

CONDENSER AIR TEMPERATURE75 85 95 105 115

SCFM WB TOTALMBTUH

SENSMBTUH

WATTSKWH

TOTALMBTUH

SENSMBTUH

WATTSKWH

TOTALMBTUH

SENSMBTUH

WATTSKWH

TOTALMBTUH

SENSMBTUH

WATTSKWH

TOTALMBTUH

SENSMBTUH

WATTSKWH

992

72 40.6 19.2 3.66 38.9 18.4 3.85 36.8 17.7 4.01 34.7 16.9 4.20 32.6 16.1 4.3967 37.1 23.8 3.42 35.4 23.0 3.58 33.6 22.3 3.77 31.5 21.5 3.97 29.4 21.5 4.1662 34.3 28.2 3.19 32.6 27.4 3.38 31.7 26.6 3.58 30.8 25.9 3.77 29.1 24.8 3.9357 32.9 30.5 3.11 31.5 29.2 3.31 30.1 27.9 3.50 28.4 26.4 3.73 27.0 24.8 3.89

1167

72 42.4 21.2 3.77 40.3 20.5 3.93 38.2 19.7 4.12 36.1 19.2 4.32 33.6 18.2 4.5167 38.9 27.1 3.54 37.1 26.4 3.69 35.0 25.6 3.89 32.9 24.8 4.08 30.8 24.1 4.2862 36.1 32.5 3.34 34.3 31.5 3.50 32.6 30.2 3.69 31.2 28.7 3.89 29.4 27.1 4.1257 35.7 33.0 3.31 34.0 31.7 3.50 32.6 30.2 3.69 31.2 28.7 3.89 29.4 27.1 4.12

1342

72 43.4 23.0 3.85 41.3 22.3 4.01 39.2 21.5 4.20 36.8 20.7 4.39 34.7 20.2 4.5967 40.3 30.0 3.62 38.2 29.4 3.77 36.1 28.7 3.97 34.0 27.6 4.16 31.9 26.9 4.3662 37.8 35.1 3.46 36.4 33.5 3.66 34.3 32.0 3.85 32.9 30.5 4.04 30.8 28.7 4.2857 37.8 35.1 3.46 36.4 33.5 3.66 34.3 32.0 3.85 32.9 30.5 4.04 30.8 28.7 4.28

Sensible heat capacities shown are based on 80 °F DB entering air at the evaporator coil. For sensible heat capacities at other than 80 °F DB, deduct 84 BTUH per 100 CFM of evaporator coil air for each degree below 80 °F, or add 84 BTUH per 100 CFM of evaporator coil air per degree above 80 °F.CAPACITIES AT 95 °F OUTDOOR, 75 °F DB AND 63 °F WB INDOORTOTAL MBTUH 33.0 SENSIBLE MBTUH 24.4 LATENT MBTUH 8.7

PCK042-1A

INDOORAIR

CONDENSER AIR TEMPERATURE75 85 95 105 115

SCFM WB TOTALMBTUH

SENSMBTUH

WATTSKWH

TOTALMBTUH

SENSMBTUH

WATTSKWH

TOTALMBTUH

SENSMBTUH

WATTSKWH

TOTALMBTUH

SENSMBTUH

WATTSKWH

TOTALMBTUH

SENSMBTUH

WATTSKWH

1190

72 48.7 24.0 4.39 46.6 23.0 4.62 44.1 22.1 4.81 41.6 21.1 5.04 39.1 20.2 5.2767 44.5 29.8 4.11 42.4 28.8 4.29 40.3 27.8 4.53 37.8 26.9 4.76 35.3 26.9 4.9962 41.2 35.2 3.83 39.1 34.2 4.06 38.0 33.3 4.29 37.0 32.3 4.53 34.9 31.0 4.7157 39.5 38.1 3.73 37.8 36.5 3.97 36.1 34.9 4.20 34.0 33.0 4.48 32.3 31.0 4.67

1400

72 50.8 26.6 4.53 48.3 25.6 4.71 45.8 24.6 4.95 43.3 24.0 5.18 40.3 22.7 5.4167 46.6 33.9 4.25 44.5 33.0 4.43 42.0 32.0 4.67 39.5 31.0 4.90 37.0 30.1 5.1362 43.3 40.6 4.01 41.2 39.4 4.20 39.1 37.8 4.43 37.4 35.8 4.67 35.3 33.9 4.9557 42.8 41.3 3.97 40.7 39.7 4.20 39.1 37.8 4.43 37.4 35.8 4.67 35.3 33.9 4.95

1610

72 52.1 28.8 4.62 49.6 27.8 4.81 47.0 26.9 5.04 44.1 25.9 5.27 41.6 25.3 5.5167 48.3 37.4 4.34 45.8 36.8 4.53 43.3 35.8 4.76 40.7 34.6 4.99 38.2 33.6 5.2362 45.4 43.8 4.15 43.7 41.9 4.39 41.2 40.0 4.62 39.5 38.1 4.85 37.0 35.8 5.1357 45.4 43.8 4.15 43.7 41.9 4.39 41.2 40.0 4.62 39.5 38.1 4.85 37.0 35.8 5.13

Sensible heat capacities shown are based on 80 °F DB entering air at the evaporator coil. For sensible heat capacities at other than 80 °F DB, deduct 84 BTUH per 100 CFM of evaporator coil air for each degree below 80 °F, or add 84 BTUH per 100 CFM of evaporator coil air per degree above 80 °F.CAPACITIES AT 95 °F OUTDOOR, 75 °F DB AND 63 °F WB INDOORTOTAL MBTUH 39.6 SENSIBLE MBTUH 30.7 LATENT MBTUH 8.9

Expanded Ratings (cont.)

Page 8: pck ss278 (jpg version) - Alpine Home Air Products Contained AC 10 SEER.pdf · 3 PRODUCT SPECIFICATIONS PCK048-1A PCK048-3A PCK060-1 PCK060-3 PCK060-4 Total Cooling-BTUH Sens. Cooling-BTUH

PRODUCT SPECIFICATIONS

8

PCK048-1A & 3A

PCK060-1, 3 & 4

Expanded Ratings (cont.)

INDOORAIR

CONDENSER AIR TEMPERATURE75 85 95 105 115

SCFM WB TOTALMBTUH

SENSMBTUH

WATTSKWH

TOTALMBTUH

SENSMBTUH

WATTSKWH

TOTALMBTUH

SENSMBTUH

WATTSKWH

TOTALMBTUH

SENSMBTUH

WATTSKWH

TOTALMBTUH

SENSMBTUH

WATTSKWH

1303

72 53.4 26.9 4.80 51.1 25.8 5.06 48.3 24.7 5.26 45.5 23.6 5.52 42.8 22.6 5.7867 48.8 33.3 4.50 46.5 32.2 4.70 44.2 31.1 4.96 41.4 30.1 5.21 38.6 30.1 5.4762 45.1 39.4 4.19 42.8 38.3 4.45 41.6 37.2 4.70 40.5 36.2 4.96 38.2 34.7 5.1657 43.2 42.6 4.09 41.4 40.8 4.34 39.6 39.0 4.60 37.3 36.9 4.91 35.4 34.7 5.11

1533

72 55.7 29.7 4.96 52.9 28.6 5.16 50.1 27.6 5.42 47.4 26.9 5.67 44.2 25.4 5.9367 51.1 37.9 4.65 48.8 36.9 4.86 46.0 35.8 5.11 43.2 34.7 5.37 40.5 33.7 5.6262 47.4 45.5 4.40 45.1 44.0 4.60 42.8 42.2 4.86 40.9 40.1 5.11 38.6 37.9 5.4257 46.9 46.2 4.34 44.6 44.4 4.60 42.8 42.2 4.86 40.9 40.1 5.11 38.6 37.9 5.42

1763

72 57.0 32.2 5.06 54.3 31.1 5.26 51.5 30.1 5.52 48.3 29.0 5.78 45.5 28.3 6.0367 52.9 41.9 4.75 50.1 41.2 4.96 47.4 40.1 5.21 44.6 38.7 5.47 41.9 37.6 5.7262 49.7 49.0 4.55 47.8 46.9 4.80 45.1 44.8 5.06 43.2 42.6 5.32 40.5 40.1 5.6257 49.7 49.0 4.55 47.8 46.9 4.80 45.1 44.8 5.06 43.2 42.6 5.32 40.5 40.1 5.62

Sensible heat capacities shown are based on 80 °F DB entering air at the evaporator coil. For sensible heat capacities at other than 80 °F DB, deduct 84 BTUH per 100 CFM of evaporator coil air for each degree below 80 °F, or add 84 BTUH per 100 CFM of evaporator coil air per degree above 80 °F.CAPACITIES AT 95 °F OUTDOOR, 75 °F DB AND 63 °F WB INDOORTOTAL MBTUH 43.4 SENSIBLE MBTUH 34.5 LATENT MBTUH 8.9

INDOORAIR

CONDENSER AIR TEMPERATURE75 85 95 105 115

SCFM WB TOTALMBTUH

SENSMBTUH

WATTSKWH

TOTALMBTUH

SENSMBTUH

WATTSKWH

TOTALMBTUH

SENSMBTUH

WATTSKWH

TOTALMBTUH

SENSMBTUH

WATTSKWH

TOTALMBTUH

SENSMBTUH

WATTSKWH

1643

72 67.3 32.6 6.06 64.4 31.3 6.38 60.9 30.0 6.64 57.4 28.7 6.96 53.9 27.4 7.2867 61.5 40.5 5.67 58.6 39.2 5.93 55.7 37.8 6.25 52.2 36.5 6.57 48.7 36.5 6.9062 56.8 47.9 5.28 53.9 46.5 5.61 52.5 45.2 5.93 51.0 43.9 6.25 48.1 42.2 6.5157 54.5 51.8 5.16 52.2 49.6 5.48 49.9 47.4 5.80 47.0 44.8 6.19 44.7 42.2 6.44

1933

72 70.2 36.1 6.25 66.7 34.8 6.51 63.2 33.5 6.83 59.7 32.6 7.15 55.7 30.9 7.4867 64.4 46.1 5.86 61.5 44.8 6.12 58.0 43.5 6.44 54.5 42.2 6.77 51.0 40.9 7.0962 59.7 55.2 5.54 56.8 53.5 5.80 53.9 51.3 6.12 51.6 48.7 6.44 48.7 46.1 6.8357 59.2 56.1 5.48 56.3 53.9 5.80 53.9 51.3 6.12 51.6 48.7 6.44 48.7 46.1 6.83

2223

72 71.9 39.2 6.38 68.4 37.8 6.64 65.0 36.5 6.96 60.9 35.2 7.28 57.4 34.4 7.6067 66.7 50.9 5.99 63.2 50.0 6.25 59.7 48.7 6.57 56.3 47.0 6.90 52.8 45.7 7.2262 62.6 59.6 5.74 60.3 57.0 6.06 56.8 54.4 6.38 54.5 51.8 6.70 51.0 48.7 7.0957 62.6 59.6 5.74 60.3 57.0 6.06 56.8 54.4 6.38 54.5 51.8 6.70 51.0 48.7 7.09

Sensible heat capacities shown are based on 80 °F DB entering air at the evaporator coil. For sensible heat capacities at other than 80 °F DB, deduct 84 BTUH per 100 CFM of evaporator coil air for each degree below 80 °F, or add 84 BTUH per 100 CFM of evaporator coil air per degree above 80 °F.CAPACITIES AT 95 °F OUTDOOR, 75 °F DB AND 63 °F WB INDOORTOTAL MBTUH 54.8 SENSIBLE MBTUH 41.6 LATENT MBTUH 13.1

Page 9: pck ss278 (jpg version) - Alpine Home Air Products Contained AC 10 SEER.pdf · 3 PRODUCT SPECIFICATIONS PCK048-1A PCK048-3A PCK060-1 PCK060-3 PCK060-4 Total Cooling-BTUH Sens. Cooling-BTUH

9

PRODUCT SPECIFICATIONS

HK 05 - 1

Electrical Designator

1 - 208 / 240 VAC, 1 PH, 50/60 HZ

3 - 208 / 240 VAC, 3 PH, 50/60 HZ

Nominal Capacity

05 - 4.75 KW

10 - 9.5 KW

15 - 14.25 KW

20 - 19.0 KW

Unit Type

HK - Optional Heat Kit

Heat Kit Model Identification

Heat Kit Electrical Data

ModelNo.

NominalK. W.

HeaterAmperage

MinimumAmpacity

Multiple Supply Circuit

MaximumOvercurrentProtection

Min. Ampacityper Circuit

Max. OvercurrentProtection

208/240V

208/240V 1 2 1 2HK05-1* 4.75 17.2/19.8 22/25 30/30HK08-1* 7.00 25.3/29.2 32/37 60/60HK10-1* 9.50 34.4/39.6 43/50 60/60HK10-3 9.50 20.7/23.6 26/30 30/30HK15-1* 14.25 51.5/59.4 65/75 90/90 22/25 43/50 30/30 60/60HK15-3 15.0 31.7/36.2 40/46 50/50HK15-4# 15.0 18.1 23 30HK20-1* 19.0 68.7/79.2 86/99 120/120 43/50 43/50 60/60 60/60HK20-3 19.6 41.4/47.2 52/59 60/60HK20-4# 19.6 23.6 30 30

* - Circuit Breaker ModelsRatings at 208/240 VAC, except where noted# - Ratings at 480 VAC, PH 3

Heat Kit Selection

MODEL PCK024-1 PCK030-1 PCK036-1 PCK036-3 PCK042-1 PCK042-3 PCK048-1 PCK048-3 PCK060-1 PCK060-3 PCK060-4HK50-1 * * * * * * * * * * *HK08-1 * * * * * * * * * * *HK10-X * * * * * * * * * * *HK15-X * * * * * * * * *HK20-X * * * * * * * *

NOTE: X = 1, 3 OR 4 Electrical Designator.

Page 10: pck ss278 (jpg version) - Alpine Home Air Products Contained AC 10 SEER.pdf · 3 PRODUCT SPECIFICATIONS PCK048-1A PCK048-3A PCK060-1 PCK060-3 PCK060-4 Total Cooling-BTUH Sens. Cooling-BTUH

PRODUCT SPECIFICATIONS

10

AccessoriesSMALL MEDIUM LARGE

Roof Curb PCCP-1 PCCP2-3 PCCP2-3Down Flow Plenum PCP-1 PCP2-3 PCP2-3Manual Fresh Air Damper PCMD-1 PCMD2-3 PCMD2-3Economizer - Down Flow PCE-1 PCE2-3 PCE2-3Square To Round Converter (Downfl ow) SQRPC-1 SQRPC2-3 SQRPC2-3Square To Round Converter (Horizontal) SQRPCH-1 SQRPCH-2 SQRPCH-3Elbow & Flashing PCEF-1 PCEF2-3 PCEF2-3Room Thermostat CHT18-60 CHT18-60 CHT18-60

NOTE - Down Flow Plenum includes Filter Rack

KW Correction FactorSupply Voltage 240 230 220 210 208Correction Factor 1.00 0.93 0.85 0.78 0.76

(Multiply the 240 VAC capacity by factors)

Chassis Sizes

SMALL MEDIUM LARGEPC024 PCK042 PCK060PC030 PCK048PC036

Page 11: pck ss278 (jpg version) - Alpine Home Air Products Contained AC 10 SEER.pdf · 3 PRODUCT SPECIFICATIONS PCK048-1A PCK048-3A PCK060-1 PCK060-3 PCK060-4 Total Cooling-BTUH Sens. Cooling-BTUH

11

PRODUCT SPECIFICATIONS

PCK PCK PCK 024 -1

Electrical Designator1 - 208/230 VAC, 1 Ph, 60 Hz3 - 208/230 VAC, 3 Ph, 60 Hz4 - 460 VAC, 3 Ph, 60 Hz

Nominal Capacity024 - 24,000 BTUH030 - 30,000036 - 36,000042 - 42,000048 - 48,000060 - 60,000

Unit TypePCK - Package Cooling(SECOND GENERATION)

ALL UNITS ARE DIRECT DRIVE

Model Identification

Page 12: pck ss278 (jpg version) - Alpine Home Air Products Contained AC 10 SEER.pdf · 3 PRODUCT SPECIFICATIONS PCK048-1A PCK048-3A PCK060-1 PCK060-3 PCK060-4 Total Cooling-BTUH Sens. Cooling-BTUH

PRODUCT SPECIFICATIONS

Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations.Copyright © 2003 Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. • Goodman products are made proudly in the USA.

12