  • ManualInstallation guidelines/Software description

    Portable Control Adapter

  • 2Contents

    Contents ..............................................................................................................................................................2

    Disclaimer ............................................................................................................................................................3

    Safety instructions ...............................................................................................................................................6Defi nitions ........................................................................................................................................................6General instructions ........................................................................................................................................6Mains lead .......................................................................................................................................................6

    General information .............................................................................................................................................8

    Introduction ..........................................................................................................................................................9

    1. USB port interface ...........................................................................................................................................101.1 Mounting of the Kathrein PCA ...................................................................................................................101.2 Installing the USB serial port .....................................................................................................................131.3 Kathrein PCA Drivers Installation Guide for Windows 7 ............................................................................17

    1.3.1 Introduction .........................................................................................................................................171.3.2 Installing Drivers .................................................................................................................................17

    2. PCA software installation .................................................................................................................................26

    3. PCA software description ................................................................................................................................293.1 Menu button Wizard Setup ......................................................................................................................353.2 Menu button Device Status ......................................................................................................................37

    3.2.1 RCU Status ........................................................................................................................................393.2.1.1 Button Set Tilt ............................................................................................................................393.2.1.2 View detail window RET .............................................................................................................40

    3.2.1.2.1 Button Set Tilt .....................................................................................................................403.2.1.2.2 Button Calibrate ..................................................................................................................413.2.1.2.3 Button Set Type ..................................................................................................................423.2.1.2.4 Button Reset .......................................................................................................................423.2.1.2.5 Button Clear Errors .............................................................................................................433.2.1.2.6 Button Set Antenna Serial Number .....................................................................................43

    3.2.2 TMA Status .........................................................................................................................................443.2.2.1 Button Set Mode ........................................................................................................................443.2.2.2 View detail window TMA ..............................................................................................................45

    3.2.2.2.1 Button Set Sector ID ...........................................................................................................453.2.2.2.2 Button Get Mode.................................................................................................................463.2.2.2.3 Button Get Gain ..................................................................................................................463.2.2.2.4 Button Set Gain ..................................................................................................................473.2.2.2.5 Button Reset .......................................................................................................................483.2.2.2.6 Button Clear Errors .............................................................................................................48

    3.3 Menu button Software Update .................................................................................................................493.3.1 Update Device Data File ...................................................................................................................493.3.2 Update the Software from the AISG device ........................................................................................49

    3.4 Menu button Report File ..........................................................................................................................523.5 Menu button View [V] / [mA] ....................................................................................................................533.6 Change the RF voltage of the feeder cable ...............................................................................................543.7 Change Device Protocol Version ...............................................................................................................55

    3.7.1 RCU ....................................................................................................................................................553.7.2 TMA ....................................................................................................................................................56

    Abbreviation index ...............................................................................................................................................57

    Addresses............................................................................................................................................................58

  • 3Disclaimer

    USER SOFTWARE LICENSE AGREEMENT

    Kathrein Werke KG; Anton Kathrein Strasse 1-3; 83022 Rosenheim (hereinafter referenced as Kathrein) agrees to grant to Customer, and Customer accepts, a license to the identifi ed Licensed Software to the terms and conditions of this agreement.

    Kathrein develops and manufactures Remote Electric Tilt antennas and systems including Mast Head Amplifi ers for Mobile Communication Networks. For control and management of RET antennas and systems, Kathrein has developed the software Portable Control Adapter (PCA)

    1. LICENSE GRANT1.1 Licensed Software means all Kathrein computer

    programs associated with the Portable Control Adapter (PCA), including any modifi cations, updates or additions as Kathrein, in its sole discretion, may supply to Customer, in object code or executable form in any medium, such as magnetic tape, disks, or optical media; and related materials such as fl ow charts, logic diagrams, manuals, and other documentation which are provided to Customer by Kathrein.

    1.2 Subject to the payment of fees elsewhere specifi ed and subject to the terms and conditions of this agreement, Kathrein grants to Customer, for the term of this agreement, a nonexclusive, non-transferable license to use Licensed Software. Should the Licensed Software include a unique implementation of a security algorithm, Customer shall have the exclusive right to use such unique Customer security algorithm implementation.

    1.3 Customer may make one (1) copy of Licensed Software for archival purposes only and shall reproduce and attach all copyright and proprietary notices. Customer shall not otherwise copy or allow to be copied Licensed Software except to install Licensed Software. Customer agrees that Kathrein shall have the right to have an independent accounting fi rm conduct an audit at Customers premises during normal business hours to verify the number of copies of Licensed Software in use by Customer. Should customers use of Licensed Software exceed that permitted by this Agreement, then customer shall pay the cost of the audit.

    1.4 Customer shall not make any modifi cations to Licensed Software or remove any proprietary notices of Kathrein or third parties found in or on the Licensed Software. Customer shall not translate, reverse engineer, decompile, disassemble or reverse assemble Licensed Software or try, directly or indirectly, to obtain or create source code of the Licensed Software except to the extent that such prohibition may be unenforceable under applicable law.

    1.5 Licensed Software is and shall remain the exclusive property of Kathrein. No license other than that specifi cally stated herein is granted to Customer, and Customer shall have no right to sublicense Licensed Software. Customer shall have no right to use any patent, trademark, copyright, trade secret or other intellectual property of Kathrein other than that granted by this agreement

    2. PROTECTION AND SECURITY2.1 Customer agrees not to disclose, release, or make

    available in any form any portion of Licensed Software to any person other than Customers own employees or contractors. Customer represents that its employees and contractors having access to Licensed Software are or shall be party to written agreements acknowledging a duty to protect Customers confi dential materials, including the Licensed Software.

    2.2 Customer shall keep Licensed Software (including archival copies, if any), in a secure environment and shall take all steps reasonably necessary to protect Licensed Software or any part thereof from unauthorized disclosure or release. Customer may not export or re-export the Licensed Software in any form except in compliance with all applicable laws and regulations.

    2.3 Customer expressly agrees that a breach of this Agreement will cause irreparable harm to Kathrein and that Kathrein shall have the right to obtain injunctive relief against any unauthorized use, disclosure, copying or transfer of any part of Licensed Software. Licensed Software may contain software from third parties who are intended to be third party benefi ciaries of this Agreement.

    3. WARRANTY AND LIABILITY3.1 Although the parties understand that software

    cannot be developed completely error free, Kathrein warrants that Licensed Software, as provided, shall substantially conform to the specifi cations provided by Kathrein for a period of one (1) year after the date of delivery of Licensed Software. During the foregoing one (1) year warranty period, Kathrein shall use commercially reasonable efforts to correct reproducible errors detected in the licensed Software after receiving notifi cation of such errors from customer. If such efforts fail, customer shall have the right to terminate the Agreement or to request a reasonable reduction of the license fee. Warranty claims are excluded:

    a) after expiry of the one (1) year warranty period b) in case of an insignifi cant deviation of Licensed

    Software from its specifi cation; or c) for errors or restrictions of use originating from

    improper installation; operation, usage, handling, maintenance or disregard of the operation manual or any other documentation.

  • 4Disclaimer

    3.2 EXCEPT AS EXPRESSELY SET FORTH IN ARTICLE 3.1, KATHREIN MAKES NO OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, WITH RESPECT TO LICENSED SOFTWARE AND ANY OTHER PRODUCTS OR SERVICES PROVIDED UNDER THIS AGREEMENT INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. KATHREIN DOES NOT WARRANT THAT THE FUNCTIONS CONTAINED IN LICENSED SOFTWARE WILL MEET THE CUSTOMERS REQUIREMENTS, OR THAT THE OPERATION OF LICENSED SOFTWARE WILL BE UNINTERRUPTED OR ERROR-FREE. ARTICLE 3.1 SETS FORTH THE ENTIRE REMEDIES OF CUSTOMER WITH RESPECT TO NON-CONFORMITY OF LICENSED SOFTWARE:

    3.3 Customer acknowledges its responsibility to use all reasonable methods to prove out and thoroughly test the operation of and output from Licensed Software prior to its use in Customers operations.

    3.4 Unless otherwise provided in writing under Kathreins Software Maintenance and Update Agreement, and subject only to the warranty of this Section 3, Kathrein is under no obligation to provide Customer with any modifi cations, updates, additions or revisions to Licensed Software, nor to maintain or provide technical support for the Licensed Software in any manner.

    3.5 In the event that any unauthorized modifi cations are made to Licensed Software by Customer, any and all warranty and other obligations of Kathrein shall immediately cease with respect to such software.

    4. INFRINGEMENT OF INTELLECTUAL PROPERTY RIGHTS AND INDEMNIFICATION

    4.1 Subject to the conditions and limitations set forth in this section 4, Kathrein shall pay all costs and damages fi nally awarded against Customer or its employees to the extent based upon a claim that Licensed Software, as supplied, infringes a patent, copyright or any other intellectual property right of a third party (except infringement occurring as a direct result of incorporating features, operations or algorithms which are specifi cally required by Customer), provided that Kathrein is notifi ed promptly in writing of any allegation of such infringement and given full cooperation, information, and authority to settle such claim and to defend or control the defense of any suit, action or proceeding based upon such claim.

    4.2 If, as a result of an infringement claim as specifi ed under section 4.1 above, Licensee becomes enjoined or is likely to become enjoined from using Licensed Software, Kathrein shall, at its option and expense, procure for Customer the right to continue using Licensed Software; or, modify Licensed Software to make it noninfringing but functionally equivalent; or, substitute other software of similar capabilities. If Kathrein determines that none of these alternatives is reasonably available, Customer shall, upon written request from Kathrein, return the Licensed Software that is the subject of the infringement claim, and Kathrein shall refund to Customer the license fee paid by Customer therefore, less twenty percent (20%) for each elapsed year or portion thereof since the date of this Agreement. However, Kathrein has no obligation of indemnity for any claim of infringement arising from Customers modifi cation of the Licensed Software, data, or its combination, operation, or use with any software, data, or equipment not specifi ed by Kathrein, or use of a superseded or altered release of the Licensed Software. In no event shall Kathreins liability under this Paragraph 4 exceed the total amount of all license fees paid by Customer hereunder for the Licensed Software that is the subject of the infringement claim. This section 4 states Kathreins entire obligation and customers exclusive remedy with respect to any claim of infringement of any third party intellectual property rights, including but not limited to any patent rights, copy rights, utility models, design patents, trademarks, trade names, trade secrets, know how and any other similar rights or intangible assets recognized under any law.

    5. LIMITATION OF LIABILITY5.1 Customer and Kathrein agree that the license

    fees for licensed Software would not adequately compensate Kathrein for assuming all risk associated with performance, breach or non-performance of this agreement, and that to avoid having to increase its license fees to adequately protect against such unlimited risk Customer and Kathrein agree to the limitation of Kathreins liability as set forth in this article 5.

    5.2 Kathreins liability is not limited for damages caused by the lack of properties expressly guaranteed by Kathrein, for damages out of bodily injuries or for damages caused by fraud or gross negligence.

  • 5Disclaimer

    5.3 Except for the cases expressly set forth in section 5.2, Kathreins liability shall be limited to a maximum amount of two (2) license fee per single event and to an aggregate amount of four (4) license fees for the entire term of the agreement. Moreover Kathrein shall not be liable for any incidental, indirect, consequential, untypical, unpredictable or punitive damages, including but not limited to lost profi ts or revenues, costs of delay, business interruption, costs of lost or damaged data or documentation of liabilities of Customer to third parties arising from any source, even if Kathrein has been advised of the possibility of such damages. Especially, Kathrein shall not be liable for any damage resulting from an interruption of the operation of any mobile communication network.

    5.4 The liability according to the German Produkthaftungsgesetz remains unaffected ( 14 ProdHaftG).

    5.5 The limitation of liability according to this section 5 applies to any kind of liability regardless whether based on contract, tort or any other legal theory.

    5.6 This article 5 shall survive any termination or expiration of this agreement.

    6. TERM AND TERMINATION This Agreement shall continue indefi nitely unless

    terminated by one of the parties. This Agreement may be terminated by Customer upon thirty (30) days notice to Kathrein and by Kathrein upon breach of any term of this Agreement, which breach is not cured within thirty (30) days after written notice by Kathrein, or should Customer cease business operations, be adjudged a bankrupt or become a party to a similar proceeding for the benefi t of its creditors. Immediately after such termination, Customer will cease use of Licensed Software, delete all parts of Licensed Software from its Hardware and deliver any and all copies and modifi cations of Licensed Software to Kathrein and, if requested, provide Kathrein with its written certifi cation that no copies have been retained.

    7. TAXES Except for taxes based on Kathreins income,

    Kathrein shall not be responsible for any federal, state or local taxes based upon Customers purchase, possession or use of Licensed Software or upon any charges payable or services performed hereunder.

    8. APPLICABLE LAW, INTEGRATION AND MODIFICATION

    8.1 This agreement shall be governed, interpreted and enforced according to the laws of Germany, not including any confl ict of law provisions thereof and not including the CISG (UN-Convention on the International Sale of Good/ UN-Kaufrecht). Place of jurisdiction shall be Traunstein, Germany.

    8.2 This Agreement comprises the full and fi nal understanding between Kathrein and Customer, and merges and supersedes any and all other agreements, understandings or representations, written or oral, with respect to the subject matter hereof. It may not be modifi ed except by a writing signed by authorized representatives of both Kathrein and Customer, and referring specifi cally to this Agreement.

    8.3 Waiver by any party of the breach of a provision of this Agreement by the other party shall not be construed as a continuing waiver of such provision or waiver of any other breach of any other provision of this Agreement.

    8.4 Severability If any provision of this agreement is invalid or

    unforceable under any applicable law or regarded as invalid or unforceable by any applicable court decision, the parties agree that such invalidity or unenforceability shall not affect the validity or enforceability of the remaining provisions and further agree to substitute for the invalid or unenforceable provision a valid and enforceable provision which most closely approximates the intent and economic effect of the invalid provision within the limits of applicable court decisions.

    Copyright (c)2006 Kathrein Werke KG. All rights reserved.

  • 6Safety instructions

    Defi nitions

    General instructions

    Before you work on any equipment, be aware of the hazards involved with electrical circuitry, and be familiar with standard practices for preventing accidents.

    Only trained and qualifi ed personnel is allowed to install, replace or service this equipment.

    Use only the power supply included in delivery to power the PCA.

    Do not work on the system or (dis)connect cables during a thunderstorm.

    The plug socket combination must be accessible at all times, as it serves as the maindisconnecting device.

    Non-observance of these instructions may damage or destroy the devices. Death or severe injuries may occur!

    Mains lead

    The details given in the installation guide and the product documentation must be carefullyfollowed during the installation and operation of the PCA (read the installation guide and the PCA product documentation thoroughly before connecting the system to the power supply).

    The installation guide has to be used in combination with the PCA product documentation on the CD-Rom (PCA Software and Documentation) delivered with each PCA.

    The installation team must be properly qualifi ed and also be familiar with the relevant national safety regulations! Non-observance of theseinstructions may damage or destroy the devices. Death or severe injuries may occur!

    WARNING

    WARNING

    Make sure that the mains lead (power supply lead) is undamaged!Never put the PCA into operation if the mains lead is damaged.

    This can jeopardize the electrical safety of the PCA.

    WARNING

    Indicates a potentially dangerous situation.Death or severe injuries may occur.

    Provides information on ensuring the safety of persons or objects.

    WARNING

    NOTICE

  • 7Safety instructions

    The disposal of this product should be effected according to all national laws and regulations.

    The power supply and the PCA are designed for indoor use.

    Only operate the power supply of the PCA using the main voltages indicated on the PCA data sheet.

    Non-observance of these instructions may result in unsuccessful operation of the RET components or destruction of the devices.

    For installing and servicing the RET system, follow the instructions in theRET manual on the PCA CD-Rom.

    RETAIN THESE INSTRUCTIONS!

    NOTICE

    NOTICE

    NOTICE

    NOTICE

    NOTICE

    NOTICE

  • 8General information

    The information published in this manual was up to date on printing.However, we reserve the right to change without notice.

    The PCA software is to be used with Microsoft Windows 2000, XP or Vista (Ultimate / Home Premium) supporting USB ports.

    In order to control the devices properly, it is essential to install the RCU on the antenna and to connect all devices to the PCA before it is switched on.

    A precondition for the proper control of the devices are correctly mounted components.

    Each RCU must be calibrated before the initial downtilt setting and after each manual adjustment of the downtilt or after each dismantling of the RCU.Non-compliance of this instruction may result in an undefi ned down-tilt setting.

    The RCU being installed on the appropriate antenna is essential for a correct RCU calibration.

    If this is not observed, the calibration cannot be carried out correctly.

    NOTICE

    NOTICE

    NOTICE

  • 9Introduction

    The RCU and TMA are mounted of and controlled with the PCA via a RS 485 bus according to the AISG standard.

    The PCA is connected to a PC or laptop via the USB port. The software to drive the PCA requires a Microsoft Windows 2000, XP, Vista or Win7 operating system.

  • 10

    1. USB port interface

    1.1 Mounting of the Kathrein PCA

    NOTICE

    Connect the PCA to the PC via a USB power supply cable. Connect the PCA to the main adapter.

    The installation on the PC described in the following applies to the Microsoft Windows 2000 operating system.

    USB connected, Kathrein PCA found.

    Click on Next to continue the installation.

  • 11

    1. USB port interface

    Select Search for a suitable driver for my device. Click on button Next.

    Select either Specify a location or CD-ROM drives. Click on button Next.

  • 12

    1. USB port interface

    Click on button Next to install the driver for the PCA.

    To complete the installation of the Kathrein PCA click on button Finish.

    Now the Kathrein PCA is installed.

  • 13

    1. USB port interface

    Click on button Next.

    1.2 Installing the USB serial port

    After the installation of the PCA is fi nished, the driver for the USB serial portmust be installed.

    The following window pops up automatically.

  • 14

    Select either Specify a location or CD-ROM drives. Click on button Next.

    Select Search for a suitable driver for my device. Click on button Next.

    1. USB port interface

  • 15

    1. USB port interface

    NOTICE

    File FTDIPORT.inf is being searched.

    Click on button Finish.

    Now all components are installed.

    If the suitable driver fi le has been found, the following window will open: Click on button Next to install the driver.

  • 16

    1. USB port interface

    NOTICE

    Open the Ports menu under: Start / Settings / Control Panel / System / System Properties / Device Manager / Ports (Com&LPT).This menu displays the COM port where the Kathrein PCA is connected.

  • 17

    1. USB port interface

    1.3 Kathrein PCA Drivers Installation Guide for Windows 7

    The purpose of this application note is to provide users of Kathrein PCA with a simple procedure for installing device drivers for Kathrein PCA devices under Microsoft Windows 7.

    1.3.1 Introduction

    1.3.2 Installing Drivers

    To install drivers for a Kathrein PCA under Windows 7, follow the instructions below:

    Connect the device to a spare USB port on your PC. If no suitable driver is automatically found the described procedure should be

    followed. Press the Windows start button to bring up the start menu and select Control

    Panel.

  • 18

    1. USB port interface

    From the Control Panel window select Device Manager.

    In the Device Manager window there will be a device under Other devices with a yellow warning symbol to indicate a problem e.g. no driver installed.

  • 19

    1. USB port interface

    Double click on the other device (KATHREIN PCA) to bring up the Properties window.

    From the displayed menu select Update Driver.

    The following window displays the option for an automatic search or a manual search:

    Select the second option to browse manually.

  • 20

    1. USB port interface

    In the address box put the exact location where the drivers are located. This is normally on the CD delivered with your KATHREIN PCA. It is not necessar-ily the exact same drive letter as shown in the screenshot.

    After entering the address select Next to start the installation.

  • 21

    1. USB port interface

    If you are certain of the source of the driver the warning can be ignored and you can continue installation by selecting Install this driver software anyway.

    When the installation has fi nished a completion screen is displayed.

    Press Close to close this window.

  • 22

    1. USB port interface

    Press Close to close the Properties window and go back to the Device-Man-ager Window.

  • 23

    1. USB port interface

    The Device Manager will still show a device under Other devices but in addi-tion to this there is a new entry under USB Controller indicated in the screen-shot above as the USB Serial Converter. This indicates the bus layer of the driver is installed. Installing the virtual Com Port layer of the driver is almost a repeat of the last few steps.

    Double click on the Other devices (USB Serial Port) to bring up the Properties window as shown below.

    From the displayed menu select Update Driver.

  • 24

    1. USB port interface

    This then displays the option for an automatic search or a manual search.

    Select the second option to browse manually. In the address box put the exact location where the drivers are located. This

    is normally on the CD delivered with your PCA. It is not necessarily the exact same drive letter as shown in the screenshot:

    After entering the address select Next to start the installation.

  • 25

    1. USB port interface

    When the installation is fi nished a completion screen is displayed:

    Note this screen also displays the COM post assigned to the device. Press Close to close this window and go back to the Device Manager Window.

    This time the Device Manager does not have a USB Serial Port under Other devices but shows entries under USB-Controller and Ports (COM & LPT). The above screen shot displays a correct installation. The Device is now ready to use on COM3.

    Note: Not all devices will install to COM3. The COM port allocation is deter-mined by the installation wizard on the basis of the next free com port as designated in the PC registry.

  • 26

    2. PCA software installation

    To install the Kathrein PCA software open the Install folder on the CD anddouble click on setup_PCA_V2-3-0.exe.

    e.g.: E:\>install>setup_PCA_V2-3-0.exe

    The following window will open: Read through the license agreement and if you accept click on button

    I Agree.

    Select the components to install.

  • 27

    2. PCA software installation

    Select the directory, you want to install the Kathrein PCA software to. If you want to install to a different directory, click on the button Browse and

    select your directory. Close the directory window with the button OK and then click on Install.

    During installation the following window pops up:

    Click on button Show details to show details for installation. Click on button Close to complete the Setup.

  • 28

    2. PCA software installation

  • 29

    3. PCA software description

    Together with the PCA, the connected hardware (RCU, TMA) is installed and controlled via the RS 485 bus according to the AISG standard.

    The PCA is connected to a PC or laptop via the USB port. The software for the drive of the PCA requires at least the Microsoft Windows 2000 operating system.

    status line

    dialogue window

    main menu

    Before starting the PCA software make sure that:

    1. The PCA is connected with the power supply.2. All devices (which should be installed) are connected to the AISG connector.

    The following screenshot shows the main window of the PCA software.

    NOTICE

    NOTICE

    If you operate an older PCA device, the software will than show the following main menu.

  • 30

    3. PCA software description

    NOTICE

    If the PCA does not fi nd the devdata.bin fi le, an error dialogue fi eld appears.

    If the PCA is not connected to the USB port, or in case of a COM port confl ict, an error dialogue fi eld appears.

    NOTICE

  • 31

    3. PCA software description

    NOTICE

    The COM port is inquired only on the initial software boot, then these data are stored in the PCA.ini fi le.Then, the COM port is correctly set permanently.

    If you click Select COM port, the following window appears. You must select the correct COM port for the PCA device. If the selected COM port is correct, the PCA software starts connecting for

    devices.

    These selections are stored in the PCA.ini fi le.

  • 32

    3. PCA software description

    To start the PCA software click on the Kathrein PCA.exe button in yourdirectory.

    You can select the language (English, German, French, Spanish, Portuguese, Russian, Arabian, Chinese).

  • 33

    3. PCA software description

    You must select the protocol mode and then click on the Start Scan andConnect button.

    These selections are stored in the PCA.ini fi le.

    The scanning procedure can also be stopped by clicking on the Stop Scan and Connect button.

  • 34

    When the device scan is fi nished, all detected devices are listed as shown in the screenshot below.

    3. PCA software description

    The PCA main window pops up and the PCA software starts connecting for devices.

    If the device was correctly connected, then switch the status fromSCANNING to OK.

    If you have devices with different protocol modes, open the following dialogue fi eld.

  • 35

    3. PCA software description

    3.1 Menu button Wizard Setup

    Open the Wizard Setup by clicking the corresponding button in the main menu and the following window will appear:

    Enter or modify the device data (Sector ID, Antenna Type, Inst. Date, Installer ID, Basestation ID).

    Number of characters are different. By setting the checkbox, the settings (Inst. Date, Installer ID, Basestation ID)

    from the upper line will be stored to all the devices. Click the Button Set Data to set and verify the entered data. Press Cancel to cancel and open the status window.

    NOTICE

    protocol mode AISG 1 3GPP / AISG 2

    Sector ID 4 32

    Basestation ID 12 32

    In the protocol mode AISG 1, the number of characters allowed for Sector ID and Basestation ID differ, with up to 4 or 12 characters respectively. In the 3GPP/AISG 2 mode, 32 characters can be entered for both Sector ID and Basestation ID.

  • 36

    3. PCA software description

    Window for the indication of the setup (parameters). Hit Back to go back (to change the settings). Click Write Data and the setup for each RCU and TMA will be carried out. Press Cancel to cancel and open the status window.

    Status indication of the setup-procedure.

  • 37

    3. PCA software description

    Press Finish to complete the Wizard Setup. The PCA now opens the Device Status menu and a new device scan will

    start automatically.

    By clicking the respective button, a device scan will be started. The scan results are displayed accordingly.

    3.2 Menu button Device Status

    If the Antenna Type of the RCU has been changed, the status bar of the RCU will show an Error. To solve this error, please calibrate the RCU. For further information see chapter 3.2.1 RCU Status.

    NOTICE

  • 38

    3. PCA software description

    View Multi-Ret Status

    View detail window Multi-ret

  • 39

    3. PCA software description

    3.2.1 RCU Status

    Enter the tilt value, and press the button Set Tilt to adjust the downtilt value.

    If the entered tilt value is out of the downtilt range, the following message pops up:

    Clicking Details, opens a new window where the selected devices data are shown.

    3.2.1.1 Button Set Tilt

  • 40

    3. PCA software description

    3.2.1.2 View detail window RET

    In this window all data and errors of the RCU are visible, and it is alsopossible to change the settings of the RCU.

    Hit Back to return to the device status window.

    3.2.1.2.1 Button Set Tilt

    Enter the tilt value and press the button Set Tilt.

  • 41

    3. PCA software description

    If the tilt value is out of the setting range, the programme gives an alarmmessage. Value out of range!

    3.2.1.2.2 Button Calibrate

    Click the button Calibrate to start the calibration.

    The default tilt value at the end of the calibration is 0.

    NOTICE

    If the RCU is calibrated but the Error status is NOT_CONFIGURED, you must select another antenna type with another Spindle length.

  • 42

    3. PCA software description

    3.2.1.2.3 Button Set Type

    Click on the box to select the Antenna Type on which the RCU is mounted to.

    Click Set Type to write the Antenna Type to the RCU.

    NOTICE

    If the antenna type was changed, the RCU has to be recalibrated.

    3.2.1.2.4 Button Reset

    Button Reset forces the RCU to do a software restart

  • 43

    3. PCA software description

    3.2.1.2.6 Button Set Antenna Serial Number

    Enter or modify the Antenna Serial Number. Click Set to write the data to the RCU.

    3.2.1.2.5 Button Clear Errors

    To clear the devices errors, click the corresponding button.

  • 44

    3.2.2 TMA Status

    3.2.2.1 Button Set Mode

    3. PCA software description

    If you click on the box, the mode of the TMA can be selected.

    Click Set Mode to set the mode to the TMA.

  • 45

    3. PCA software description

    In this window the device details are shown and the errors reported. It is also possible to change the settings of the TMA in this window. Click Back to return to the status window.

    3.2.2.2 View detail window TMA

    3.2.2.2.1 Button Set Sector ID

    It is possible to set a sector ID to each TMA. Click Set Mode to save the entered ID.

  • 46

    3.2.2.2.2 Button Get Mode

    Button Get Mode retrieves the current mode of the selected TMA.

    3. PCA software description

    3.2.2.2.3 Button Get Gain Button Get Gain retrieves the TMAs current gain value.

    NOTICE

    protocol mode AISG 1 3GPP / AISG 2

    Sector ID 4 32

    Basestation ID 12 32

    In the protocol mode AISG 1, the number of characters allowed for Sector ID and Basestation ID differ, with up to 4 or 12 characters respectively. In the 3GPP/AISG 2 mode, 32 characters can be entered for both Sector ID and Basestation ID.

  • 47

    3. PCA software description

    When the TMA has variable gain values, the gain value must be selected.

    Click on the box to select the TMA gain value. Then click Set Gain to confi rm the new gain value.

    3.2.2.2.4 Button Set Gain

  • 48

    3.2.2.2.5 Button Reset

    3. PCA software description

    3.2.2.2.6 Button Clear Errors

    To clear the TMAs errors, click the corresponding button.

    Button Reset forces the TMA to do a software restart.

  • 49

    3. PCA software description

    3.3 Menu button Software Update

    Open the following window by clicking the button Software Update in themain menu.

    3.3.1 Update Device Data File

    With Search you can open a directory window to select the fi le to upload the devdata.bin fi le.

    3.3.2 Update the Software from the AISG device

    NOTICE

    All RCUs and TMAs for the software download are listed there.

    With Select you can open a directory window to select the fi le for the fi rmware update or bootloader update.

  • 50

    Select the appropriate fi le. Click Open to accept the fi le.

    3. PCA software description

    This procedure has to be repeated for each RCU or TMA. Click Start to start the download.

  • 51

    3. PCA software description

    NOTICE

    The download progress is shown in the status indication bar. An abort is possible with Cancel.

    The download for one RCU takes about 6 min and for the DTMA about 7 min.Attention!

    When the download is fi nished, the button Finish becomes active. Press Finish to change to the window Device Status and a new device

    scan will start automatically.

    In case of an abort, the RCU operates only with the bootloader (minimuminstruction set) and requires a fi rmware update!

    Attention!

    NOTICE

  • 52

    3. PCA software description

    The downloads for the boot loader and fi rmware are executed in sequential and separately.

    Attention!

    NOTICE

    Please consider the following:The fi rst four digits (e.g. 01.01) of the boot loader version number mustcomply with the fi rmware version number.

    NOTICE

    The fi le devdata.bin is located in the PCA folder.You must update this fi le for new antennas. You can download it from the cus-tomer portal on our homepage: www.kathrein.de.

    3.4 Menu button Report File

    All device data are saved in the report fi le in ASCII format. The fi le extensionis .txt.

    All device data of all connected components can be saved in a report fi le. Additional comments as well as Installation Company, Installers Name

    and Installation Date can be entered in the corresponding fi eld. Press Cancel to return to the status window. Click Save to open the Save as dialogue.

    NOTICE

  • 53

    3. PCA software description

    Select the folder where the report fi le should be stored. Enter the fi les name and click Save.

    3.5 Menu button View [V] / [mA]

    The new PCA hardware can measure the current and voltage from the AISG bus and the RF socket.

    Voltage current

    Feeder 10 - 30 V 10 - 2500 mA

    AISG 12V 10 - 15 V 10 - 2500 mA

    AISG 24V 20 - 30 V 10 - 2500 mA

    Measurement range:

    NOTICE

    The PCA will shut down if output power from all currents and voltages exceeds 70 W or if the maximum current from one line is higher than 3000 mA.

  • 54

    3. PCA software description

    3.6 Change the RF voltage of the feeder cable

    The new Kathrein PCA has a special RF socket.

    You can change the voltage of the RF socket from 12V to 24V.

    Before you change the voltage, you must press the button yes in the fi rstmessagebox and in the second messagebox.

    The second messagebox is for safety, because not all devices support 24V.

  • 55

    3. PCA software description

    3.7 Change Device Protocol Version

    When * appears on the right next to RCU Detailed Setup or TMA Detailed Setup, click * to open a new dialog.

    3.7.1 RCU

    * opens a new dialog

    The asterisk is only visible if the PCA is able to switch ALD protocol version.

    NOTICE

    In this dialog you can load a new confi g data fi le in the RCU.Select the fi le with click File and send the data with the button Set.

  • 56

    3. PCA software description

    * opens a new dialog

    The asterisk is only visible if the PCA is able to switch ALD protocol version.TMA and RCU views are different!

    NOTICE

    3.7.2 TMA

  • 57

    Abbreviation index

    AISG Antenna Interface Standard GroupCCU Central Control UnitCD-ROM Compact Disc-Read Only MemoryDHCP Dynamic Host Confi guration ProtocolEEPROM Electrically Erasable Programmable Read Only MemoryHTML Hypertext Markup LanguageHTTP Hyper Text Transfer ProtocolID Identifi cationIP Internet ProtocolLAN Local Area NetworkPAP Password Authentication ProtocolPC Personal ComputerPCA Portable Control AdapterPPP Point to Point ProtocolRAM Random Access MemoryRCU Remote Control UnitRET Remote Electrical TiltTMA Tower Mounted Amplifi erTCP/IP Transmission Control Protocol/Internet ProtocolUMTS Universal Mobile Telecommunications SystemURL Uniform Resource LocatorUSB Universal Serial BusWAN Wide Area Network

  • 58

    Addresses

    For all marketing-related enquiries:

    Fax: +49 8031 184-820

    E-mail: [email protected]

    RET hotline for technical information:

    Fax: +49 8031 184-973

    E-mail: [email protected]

  • 59

    NOTICE

  • 940.

    8296

    /D/0

    511/

    ZWT

    - Tec

    hnic

    al d

    ata

    subj

    ect t

    o ch

    ange

    .

    NOTICE

    Internet: http://www.kathrein.deKATHREIN-Werke KG . Phone +49 8031 184-0 . Fax +49 8031 184-494Anton-Kathrein-Strae 1 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany