pc350 temporary hospital room divider proposal - option a · project: #descriptiondate pc350...
TRANSCRIPT
APPROVED BY:
DRAWN BY:
SHEET NO.:
DRAWING TITLE:
PROJECT:
# DESCRIPTION DATE
PC350 TEMPORARY HOSPITALROOM DIVIDER PROPOSAL -OPTION A
C.H.
BY
CLIENT:
ARCHITECT/DESIGNER:
PC#: ----
----
- Proposal Package 04/21/20 CH
PC350 TEMPORARY HOSPITAL ROOM DIVIDER PROPOSAL - OPTION A
TP
Title Page
Panel Option (A)
Panel Option (B)
Panel Option (C)
APPROVED BY:
DRAWN BY:
SHEET NO.:
DRAWING TITLE:
PROJECT:
# DESCRIPTION DATE
PC350 TEMPORARY HOSPITALROOM DIVIDER PROPOSAL -OPTION A
C.H.
BY
CLIENT:
ARCHITECT/DESIGNER:
PC#: ----
----
- Proposal Package 04/21/20 CH
FP
Overall View (10 Rooms)
2'-6" [762MM]2'-6" [762MM] 3'-0" [914MM]
8'-0
" [24
38M
M]
Ventilator
Drug Therapy
4'-0
" [12
19M
M]
4'-0
" [12
19M
M]
8'-0
" [24
38M
M]
4'-0
" [12
19M
M]
4'-0
" [12
19M
M]
8'-0" [2438MM]4'-0" [1219MM] 4'-0" [1219MM]
6'-8
" [20
32M
M]
APPROVED BY:
DRAWN BY:
SHEET NO.:
DRAWING TITLE:
PROJECT:
# DESCRIPTION DATE
PC350 TEMPORARY HOSPITALROOM DIVIDER PROPOSAL -OPTION A
C.H.
BY
CLIENT:
ARCHITECT/DESIGNER:
PC#: ----
----
- Proposal Package 04/21/20 CH
Plan View - Single Unit
E-1
4'-0
" [12
19M
M]
8'-834" [2661MM]
8'-0" [2438MM]
7'-1
01 4" [23
94M
M]
16'-0
7 8" [48
99M
M]
50'-658" [15408MM]
4'-0
" [12
19M
M]
4'-0
" [12
19M
M]
8'-834" [2661MM]
8'-0" [2438MM]
7'-1
01 4" [23
94M
M]
18'-5
1 4" [56
20M
M]
50'-658" [15408MM]
4'-0
" [12
19M
M]
2'-0
" [6
10M
M]
Mechanical Chase (as required)
8'-2
5 8" [25
05M
M]
25 8" [6
7MM
]
APPROVED BY:
DRAWN BY:
SHEET NO.:
DRAWING TITLE:
PROJECT:
# DESCRIPTION DATE
PC350 TEMPORARY HOSPITALROOM DIVIDER PROPOSAL -OPTION A
C.H.
BY
CLIENT:
ARCHITECT/DESIGNER:
PC#: ----
----
- Proposal Package 04/21/20 CH
Plan View - 12 Unitswith and without MechanicalChase
E-2
4'-0" [1219MM]
8'-0
" [24
38M
M]
APPROVED BY:
DRAWN BY:
SHEET NO.:
DRAWING TITLE:
PROJECT:
# DESCRIPTION DATE
PC350 TEMPORARY HOSPITALROOM DIVIDER PROPOSAL -OPTION A
C.H.
BY
CLIENT:
ARCHITECT/DESIGNER:
PC#: ----
----
- Proposal Package 04/21/20 CH
Panel Option A
E-3
8'-0
" [24
38M
M]
8'-0" [2438MM]438"
[111MM]
13 4" [44
MM
]13 4" [
44M
M]
H1 H1
H2 H2
438"
[111MM]
ICorporation
M OC
USE NO OIL
Optional lighting to bemounted to top frame
Hole cut for electrical
Wall outlets -as required
APPROVED BY:
DRAWN BY:
SHEET NO.:
DRAWING TITLE:
PROJECT:
# DESCRIPTION DATE
PC350 TEMPORARY HOSPITALROOM DIVIDER PROPOSAL -OPTION A
C.H.
BY
CLIENT:
ARCHITECT/DESIGNER:
PC#: ----
----
- Proposal Package 04/21/20 CH
Front View
E-4
8'-0
" [24
38M
M]
8'-0" [2438MM]
4'-0" [1219MM] 4'-0" [1219MM] 13 4" [44
MM
]13 4" [
44M
M]
FrontBack
APPROVED BY:
DRAWN BY:
SHEET NO.:
DRAWING TITLE:
PROJECT:
# DESCRIPTION DATE
PC350 TEMPORARY HOSPITALROOM DIVIDER PROPOSAL -OPTION A
C.H.
BY
CLIENT:
ARCHITECT/DESIGNER:
PC#: ----
----
- Proposal Package 04/21/20 CH
Side View
E-5
8'-0
" [24
38M
M]
8'-0" [2438MM]
4'-0" [1219MM] 4'-0" [1219MM] 13 4" [44
MM
]13 4" [
44M
M]
Hole cut for electrical
Steel stud for support
APPROVED BY:
DRAWN BY:
SHEET NO.:
DRAWING TITLE:
PROJECT:
# DESCRIPTION DATE
PC350 TEMPORARY HOSPITALROOM DIVIDER PROPOSAL -OPTION A
C.H.
BY
CLIENT:
ARCHITECT/DESIGNER:
PC#: ----
----
- Proposal Package 04/21/20 CH
Back View
E-6
APPROVED BY:
DRAWN BY:
SHEET NO.:
DRAWING TITLE:
PROJECT:
# DESCRIPTION DATE
PC350 TEMPORARY HOSPITALROOM DIVIDER PROPOSAL -OPTION A
C.H.
BY
CLIENT:
ARCHITECT/DESIGNER:
PC#: ----
----
- Proposal Package 04/21/20 CH
Details: H1
D-1Horizontal Section H1
Stud for electricalsupport
Wall outlets -as required
APPROVED BY:
DRAWN BY:
SHEET NO.:
DRAWING TITLE:
PROJECT:
# DESCRIPTION DATE
PC350 TEMPORARY HOSPITALROOM DIVIDER PROPOSAL -OPTION A
C.H.
BY
CLIENT:
ARCHITECT/DESIGNER:
PC#: ----
----
- Proposal Package 04/21/20 CH
Details: Accessory Detail atback panel
D-2
3
1
2
"
1
3 4
"
4
3
8
"
3
1
2
"
1
3 4
"
4
3
8
"
APPROVED BY:
DRAWN BY:
SHEET NO.:
DRAWING TITLE:
PROJECT:
# DESCRIPTION DATE
PC350 TEMPORARY HOSPITALROOM DIVIDER PROPOSAL -OPTION A
C.H.
BY
CLIENT:
ARCHITECT/DESIGNER:
PC#: ----
----
- Proposal Package 04/21/20 CH
Details: V1
D-3Sliding door vertical - Option AV1