paul ziemkiewicz, phd director, west virginia water research institute west virginia acid mine...

26
Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research Institute West Virginia University 1 Selenium weathering kinetics and at-source control

Upload: thomas-hale

Post on 26-Mar-2015

218 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

Paul Ziemkiewicz, PhDDirector, West Virginia Water Research Institute

West Virginia Acid Mine Drainage Task Force Annual Symposium

30 Mar 10

Water Research InstituteWest Virginia University1

Selenium weathering kinetics and at-source control

Page 2: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

Selenium Weathering In Spoil

Water Research InstituteWest Virginia University2

Postulated selenium weathering process:

1. Selenide: Se-2 FeSe Oxidizes to:

2. Selenite: Se+4 SeO32- Sorbs to FeO(OH)

Oxidizes to:3. Selenate: Se+6 SeO4

2- Highly Mobile !!

The trick is to catch selenium at step #2

Page 3: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

Selenium forms determined by pH and redox

Water Research InstituteWest Virginia University3

The pH range that we care

about

Selenate

Selenite

Selenide

Elemental Se (solid)

Electron gain(reduction)

Electron loss(oxidation)

Page 4: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

Selenium leaching study: Coal Refuse

Water Research InstituteWest Virginia University4

Begun in November 2008 at WRI lab Objective, to Identify:

What proportion of selenium is leachableHow rapidly selenium will leach from coal refuseHow to immobilize leached selenium

Method:Samples of coal refuse were placed in humidity cellsTreatments: ferrihydrite, steel wool, FGD cakeLeachate collected every two weeks

Page 5: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

How much selenium is mobile?

1. Selenium concentrations in rock vary between non detect and 10 mg/kg

2. The actionable level is generally 1.0 mg/kg3. Most of the problematic rock is between 2 and 5 mg/kg4. The extractable fraction is between 20% and 40%,

averaging about 33%5. That includes the organically bound selenium fraction

which may not, in fact, be mobile

Water Research InstituteWest Virginia University5

Page 6: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

Distribution of Selenium in Kanawha Formation (from Roy and Vesper sequential extraction study):

Refuse values are averages of shale and coal

Water Research InstituteWest Virginia University6

Org shale Coal Refuse

Soluble/Exchange 12% 10% 11%

Fe, Mn Oxides 0% 0% 0%

Sulfides 10% 10% 11%

Organic 18% 5% 11%

total extracted 40% 25% 33%

Residual 60% 75% 68%

Total 100% 100% 100%

Page 7: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

Another quicker way to identify how much of the rock’s Se is mobile

Water Research InstituteWest Virginia University7

Pumure, J.J. Renton, R.B. Smart, 2010 Ultrasonic extraction of arsenic and selenium from rocks associated with mountaintop removal/valley fills coal mining: Estimation of bioaccessible concentrations Chemosphere 78 (2010) 1295–1300

Rock Sequential UltrasonicSample # extraction extraction

BT 61 19% 17%BT 241 26% 24%BT 572 38% 38%BT 701 60% 48%

average 36% 32%

Page 8: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

Fig. 7. Comparison of total Se obtained using UE and sequential extractiontechniques. Combined water, exchangeable and NaOH soluble extracts are considered bioaccesible.

Water Research InstituteWest Virginia University8

Page 9: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

64 Week Leaching Study

1. The initial selenium leaching rate was about 0.07%/day

2. Declines gradually after about 30 weeks

3. After 64 weeks of laboratory leachingFeO(OH) kept [Se] near to or below 5 μg/L

Water Research InstituteWest Virginia University9

Page 10: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

Ferrihydrite has kept [Se] under control for 64 weeks

Water Research InstituteWest Virginia University10

Page 11: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

Does 5 μg/L really mean 5 μg/L?

Water Research InstituteWest Virginia University11

The refuse pile in question leaches the conservative anion chloride as well as selenium

The liquid to solid ratio for each leach cycle was about 2:1The resulting concentration was adjusted mathematically

such that chloride concentration in the leachate matched that for the field site (a several million ton refuse pile)

So, it’s a reasonable assumption for the time beingBut, it’s unlikely that a field site will leach with the

efficiency of a humidity cell so let’s not get carried away

Page 12: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

Assume 33% of Se is leachable:leaching rate ~ 0.07%/day

Water Research InstituteWest Virginia University12

Page 13: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

Estimated 10 years to leach 90%

Water Research InstituteWest Virginia University13

Page 14: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

Ferrihydrite Field Trials: Hobet 21

1. Installed in March 20102. Each cells consists of about 60 tons of selenium rich pit

cleanings3. Pit cleanings were placed over different thicknesses of

ferrihydrite4. Ferrihydrite originated at a passive treatment system Supplied

by Hedin Environmental Services5. Each cell is lined with plastic and drains to a 330 gal tank6. Chemistry and volume will be taken bi weekly

Water Research InstituteWest Virginia University14

Page 15: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

Cross-section of ferrihydrite test cell

Water Research InstituteWest Virginia University15

Pit cleanings

FeOOH

Sandstone

24 ft. long x 16 ft. wide

3 ft.4 ft.

Page 16: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

Test cell application rates and plot layout

Water Research InstituteWest Virginia University16

1 16

2 173 184 195 206 217 228 239 24

10 2511 2612 2713 2814 2915 30

Individual water collection tanks

Ferrihydriteapplication rate

% tons in.0.0% 0.0 0.000.4% 0.2 0.252.8% 1.7 2.25

11.3% 6.8 9.0022.5% 13.6 18.00

Page 17: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

Plastic liner and underdrain

Water Research InstituteWest Virginia University17

Page 18: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

Ferrihydrite placement

Water Research InstituteWest Virginia University18

Page 19: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

Ferrihydrite prior to addition of pit cleanings: ~20% moisture

Water Research InstituteWest Virginia University19

Page 20: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

Placement of pit cleanings over ferrihydrite

Water Research InstituteWest Virginia University20

Page 21: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

Water collection tanks

Water Research InstituteWest Virginia University21

Page 22: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

Overview: 30 cells

Water Research InstituteWest Virginia University22

Page 23: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

Segregated Pit Cleaning Cell

Water Research InstituteWest Virginia University23

Page 24: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

Special Handling Cell:Ferrihydrite application in unlined cell

Water Research InstituteWest Virginia University24

Ferrihydrite/pit cleanings blend

Pit cleanings

Ferrihydrite/pit cleanings blend

Pit cleanings

Soil/spoil

Page 25: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

Questions?

Paul Ziemkiewicz, PhD, DirectorWest Virginia Water Research Institute

West Virginia University

Water Research InstituteWest Virginia University25

Page 26: Paul Ziemkiewicz, PhD Director, West Virginia Water Research Institute West Virginia Acid Mine Drainage Task Force Annual Symposium 30 Mar 10 Water Research

Water Research InstituteWest Virginia University26