patient monitor - mediquip · 2020-03-14 · patient monitor bm5 enhanced & expendable...

2
SUPERIOR ADVANTAGES Patient Monitor BM5 Enhanced & expendable multi-parameter patient monitor ECG, SpO , NIBP, Respiration, 2IBP, 2Temperature, EtCO 10.4” color TFT LCD with 6 waveforms Individual sweep speed setting for each parameter 128 full hours trend data are stored SpO measurement with very low perfusion detection and pulse beep Screen freeze ON/OFF External VGA output for large screen (Option) Connected to BM Central monitoring system using LAN or W-LAN Li-ion Battery with longer life time (1 hour for continous operation) Enhanced & extendible multi-parameter • Mainstream/Sidestream EtCO (Option) • 12Ch ECG Measurement Module (BM5 CS, BM5 CX) • High-performance Suntech NIBP (BM5 XP, BM5 CX) High-performance ECG detection and analysis • Enhanced Input impedance for dry skin or electrode patch • ST level, PVC count real-time display • 13 kinds of Arrhythmia analysis • Pacemaker detection function • 120 kinds of resting ECG analysis (BM5 CS, BM5 CX) Enhanced data management • Graphical and Tabular trends • 20cases * 10 sec alarm waveform are stored, reviewed and printed www.ebionet.com

Upload: others

Post on 15-Aug-2020

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Patient Monitor - Mediquip · 2020-03-14 · Patient Monitor BM5 Enhanced & expendable multi-parameter patient monitor ECG, SpO₂, NIBP, Respiration, 2IBP, 2Temperature, EtCO₂

Superior AdvAntAgeS

Patient Monitor

BM5Enhanced & expendable

multi-parameter patient monitor

ECG, SpO₂, NIBP, Respiration, 2IBP, 2Temperature, EtCO₂

10.4” color TFT LCD with 6 waveforms

Individual sweep speed setting for each parameter

128 full hours trend data are stored

SpO₂ measurement with very low perfusion detection and pulse beep

Screen freeze ON/OFF

External VGA output for large screen (Option)

Connected to BM Central monitoring system using LAN or W-LAN

Li-ion Battery with longer life time(1 hour for continous operation)

►►►►►

►►►

Enhanced & extendible multi-parameter• Mainstream/Sidestream EtCO₂ (Option)• 12Ch ECG Measurement Module (BM5 CS, BM5 CX)• High-performance Suntech NIBP (BM5 XP, BM5 CX)

High-performance ECG detection and analysis• Enhanced Input impedance for dry skin or electrode patch• ST level, PVC count real-time display• 13 kinds of Arrhythmia analysis• Pacemaker detection function• 120 kinds of resting ECG analysis (BM5 CS, BM5 CX)

Enhanced data management• Graphical and Tabular trends• 20cases * 10 sec alarm waveform are stored, reviewed and printed

www.ebionet.com

Page 2: Patient Monitor - Mediquip · 2020-03-14 · Patient Monitor BM5 Enhanced & expendable multi-parameter patient monitor ECG, SpO₂, NIBP, Respiration, 2IBP, 2Temperature, EtCO₂

Standard 5-lead patient cable 1ea Electrodes 10ea NIBP extension hose(3m) 1ea Reusable adult cuff(25-35cm) 1ea SpO2 extension cable(2m) 1ea Reusable adult SpO2 probe 1ea DC adapter(18VDC, 2.5A) with power cord 1eaOptional Paper roll(2 rolls are included in printer type) Reusable temperature probe (Surface/Rectal) IBP transducer set (Disposable/Reusable) Sidestream EtCO2 module (Respironics) Mainstream EtCO2 module (Respironics) Sidestream EtCO2 airway adapter kit Mainstream EtCO2 airway adapter kit 3-Lead patient cable 10-Lead patient cable NIBP cuff(Reusable/Disposable)

Accessories

Ordering Name Function descriptionBM5 7Ch, ECG, SpO2, Bionet NIBP, 2TEMP, 2IBP, EtCO2

BM5 XP 7Ch, ECG, SpO2, Suntech NIBP, 2TEMP, 2IBP, EtCO2

BM5 CS 12Ch ECG, SpO2, Bionet NIBP, 2TEMP, 2IBP, EtCO2

BM5 CX 12Ch ECG, SpO2, Suntech NIBP, 2TEMP, 2IBP, EtCO2

Order Specification

Mainstream EtCO2 module(Respironics) Sidestream EtCO2 module(Respironics)

Optional Module

Method Thoracic impedanceChannel Selection RA-LA or RA-LLMeasurement range 5 to 120 Breath per minuteAccuracy ± 1breath per minuteApnea alarm Yes

Respirations

Method OscillometryOperation mode Manual/Automatic/ContinuousPressure range 0 to 300mmHg (Accuracy ±3mmHg)Measurement range Adult Pressure : 20 to 260 mmHg Pediatric Pressure : 20 to 230 mmHg Neonate Pressure : 20 to 120 mmHgAccuracy Mean error : less than ±5 mmHg Standard deviation : less than 8mmHg

Bionet NIBP

Method OscillometryOperation mode Manual/Automatic/ContinuousPressure range 0 to 300mmHg (Accuracy ±3mmHg)Safety pressure Adult : 300 mmHg Neonate : 150 mmHgMeasurement Range Adult Pressure : 20 to 260 mmHg Pulse Rate : 30 to 220 BPM Pediatric Pressure : 20 to 160 mmHg Pulse Rate : 30 to 220 BPM Neonate Pressure : 20 to 130 mmHg Pulse Rate : 30 to 220 BPMAccuracy Meets accuracy requirements of ANSI/AAMI SP10 : 1992 AND 2002

Suntech NIBP (Option)

Channels 2Measurement range -50 to 300mmHgAccuracy <100mmHg : ±1mmHg >=100mmHg : ±1% of readingPulse rate range 0 to 300bpmZero balancing Range : ±200mmHg Accuracy : ±1mmHg Drift : ±1mmHg over 24hoursTransducer sensitivity 5μV/mmHg

IBP(Option)

Channels 2Measurement range 0 to 50℃ (32 to 122℉)Accuracy 25℃ to 50℃ : ±0.1℃ 0℃ to 24℃ : ±0.2℃Compatibility YSI Series 400 temperature probes

Temperature

Saturation range 0 to 100%Saturation accuracy 70 to 100% ±2 digits, 0 to 69% unspecifiedPulse rate range 30 to 254 bpmPulse rate accuracy ± 2 bpm

SpO2

Measurement range 0 to 150 mmHg, 0 to 19%Accuracy 0 to 40mmHg ±2 mmHg, 41 to 70mmHg ±5% of reading, 71 to 100mmHg ±8% of reading, 101 to 150mmHg ±10% of readingRespiration rate 2 to 150 breath per minuteRespiration accuracy ±1 breath per minute

Sidestream EtCO2 - Respironics (Option)

Measurement range 0 to 150 mmHg, 0 to 19%Accuracy 0 to 40mmHg ±2 mmHg, 41 to 70mmHg ±5% of reading, 71 to 100mmHg ±8% of reading, 101 to 150mmHg ±10% of readingRespiration rate 0 to 150 breath per minuteRespiration accuracy ±1 breath per minute

Mainstream EtCO2 - Respironics (Option)

* Specifications can be changed without prior notification.* You may have distortion or signal noise when you use nonstandard or other brand's accessories. We strongly recommend you use only the authorized accessories which we supply.

General Performance

SpecificAtionS

Display, Resolution 10.4” color TFT LCD, 800 x 600 pixelsDimension, Weight 270(W) x 250(H) x 184.5(D) mm, Approx. 4.0kgTrace 6 waveforms : 2*ECG, SpO2, RR or EtCO2, 2*IBP Sweep speed : 6.25, 12.5, 25, 50 mm/secIndicators Categorized alarms (3 priority levels) Visual alarm lamp handle QRS beep & SpO2 Pulse beep Percent(%) SpO2 pitch tone

Battery status, Enternal Power LED Rotary knobInterfaces Power supply : AC 100-240V(50/60Hz) DC input connector : 18VDC, 2.5A Defibrillator Sync. Output : - Signal Level : 0 to 5V pulse - Pulse width : 100 ± 10ms LAN digital output for transferring data Nurse Call System connection : - 0.3A at 125 VAC - 1A at 24 VDC External VGA monitor connection DC output : 5VDC, 1A MaxBattery Rechargeable Li-ion battery, 1hour for continuous operation Thermal Printer(Option) Speed : 25,50mm/sec, Paper width : 58mmData Storage 128hours trends 20cases of 10sec alarm waveformLanguage English, French, Spanish, Italian, German, Chinese, Russian, Czech, Polish, Turkish, Romanian, Portuguese Bulgarian, Hungarian, Korean

ECGLeads Type 3-lead, 5-leadLead Selection 3-lead : I, II, III 5-lead : I, II, III, aVR, aVL, aVF, VECG waveforms 3-lead : 1 channel 5-lead : 2/7 channelsHeart Rate Range Adult : 30 to 300 bpm, Neonate/Pediatric : 30 - 350 bpmHeart Rate Accuracy ± 1bpm or ± 1%, whichever is greaterSweep speed 6.25, 12.5, 25, 50 mm/secFilter - Diagnosis : 0.05 to 150 Hz - Monitoring : 0.5 to 40 Hz - Moderate : 0.5 to 25 Hz - Maximum : 5 to 25 HzS-T segment detection range -2.0 to 2.0 mVArrhythmia analysis ASYSTOLE, VTACH, VFIB, BIGEMINY, ACCVENT, COUPLET, IRREGULAR, PAUSE, PVC, RONT,TRIGMINY, VBRADY, SHORTRUNPacemaker Detection Mode Indicator on waveform display (user selectable)Protection Against electrosurgical interference and defibrillation

Lead type 3-lead, 5-lead, 10-leadLead Selection 3-lead : I, II, III 5-lead : I, II, III, aVR, aVL, aVF, V 10-lead : I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6ECG waveforms 3-lead : 1 channel 5-lead : 2/7 channels 10-lead : 12 channelsHeart Rate Range Adult : 30 to 300bpm, Neonate/Pediatric : 30 to 350 bpmHeart Rate Accuracy ± 1 bpm or ± 1%, whichever is greaterSweep speed 6.25, 12.5, 25, 50 mm/secFilter - Diagnosis : 0.05 to 150 Hz - Monitoring : 0.5 to 40 Hz - Moderate : 0.5 to 25 Hz - Maximum : 5 to 25 HzS-T segment detection range -2.0 to 2.0 mVArrhythmia analysis ASYSTOLE, VTACH, VFIB, BIGEMINY, ACCVENT, COUPLET, IRREGULAR, PAUSE, PVC, RONT, TRIGMINY, VBRADY, SHORTRUNDiagnostic analysis 120 kindsPacemaker Detection Mode Indicator on waveform display (user selectable)Protection Against electrosurgical interference and defibrillation

12 Channel ECG (Option)

North America (U.S.A) : Bionet America, Inc. Tel : +1-714-734-1760

South Korea : Bionet co., Ltd. Tel : +82-70-7585-6418(Int'l) +82-2-6300-6483(Domestic)

Latin America : Bionet Latin America, Inc. Tel : +1-949-800-9585

Europe : MGB Endoskopische Geräte GmbH Berlin(Germany) Tel : +49-30-6392-7000

E-mail : [email protected]

E-mail : [email protected](Int'l)/ [email protected](Domestic) www.ebionet.com

E-mail : [email protected]

E-mail : [email protected]

2013

06-B

ione

t(BM

5)-R

3.0