pasi test facility - safir2018safir2018.vtt.fi/finalseminar/22032019/1_2_integra.pdf · §...

14

Upload: others

Post on 22-May-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PASI TEST FACILITY - SAFIR2018safir2018.vtt.fi/finalseminar/22032019/1_2_INTEGRA.pdf · § Pressure, differential pressure, flow transducers, and K-type thermocouples § Facility
Page 2: PASI TEST FACILITY - SAFIR2018safir2018.vtt.fi/finalseminar/22032019/1_2_INTEGRA.pdf · § Pressure, differential pressure, flow transducers, and K-type thermocouples § Facility

PASI TEST FACILITYVesa Riikonen, Virpi Kouhia,

Otso-Pekka Kauppinen, Joonas Telkkä

LUT University / Nuclear Engineering

INTEGRA SAFIR2018 - Final seminar 21.-22.3.2019 2

Page 3: PASI TEST FACILITY - SAFIR2018safir2018.vtt.fi/finalseminar/22032019/1_2_INTEGRA.pdf · § Pressure, differential pressure, flow transducers, and K-type thermocouples § Facility

INTEGRAL TEST FACILITIES§ Rewet-I (1976)§ Rewet-II (1980)§ Rewet-III (1984)§ REWET-MARIA (1986)§ VEERA (1987)§ PACTEL (1989)§ PWR PACTEL (2009)§ MOTEL (under construction)

INTRODUCTION (1/2)

3INTEGRA SAFIR2018 - Final seminar 21.-22.3.2019

Page 4: PASI TEST FACILITY - SAFIR2018safir2018.vtt.fi/finalseminar/22032019/1_2_INTEGRA.pdf · § Pressure, differential pressure, flow transducers, and K-type thermocouples § Facility

SEPARATE EFFECT TEST FACILITIES§ BWR 90+ core catcher§ EPR core catcher§ SWR 1000 fast boron injection system§ SWR 1000 scram tank§ PPOOLEX

INTRODUCTION (2/2)

4INTEGRA SAFIR2018 - Final seminar 21.-22.3.2019

Page 5: PASI TEST FACILITY - SAFIR2018safir2018.vtt.fi/finalseminar/22032019/1_2_INTEGRA.pdf · § Pressure, differential pressure, flow transducers, and K-type thermocouples § Facility

§ Review on passive heat removalsystems in NPPs in Finland

§ Selected system: passivecontainment cooling systemPHRS-C of AES-2006

§ Goal is to detect issues thatcould disturb the operation of apassive system or prevent it fromfunctioning as designed

REVIEW OF PASSIVE SYSTEMS

5INTEGRA SAFIR2018 - Final seminar 21.-22.3.2019

Page 6: PASI TEST FACILITY - SAFIR2018safir2018.vtt.fi/finalseminar/22032019/1_2_INTEGRA.pdf · § Pressure, differential pressure, flow transducers, and K-type thermocouples § Facility

§ Heat exchangers in the dome part ofthe containment

§ Emergency heat removal water tanksoutside the containment

§ Four identical and independentsubsystems

§ Each subsystem includes four heatexchanger loops

§ One heat exchanger loop is modelled

AES-2006 PHRS-C SYSTEM

6INTEGRA SAFIR2018 - Final seminar 21.-22.3.2019

Page 7: PASI TEST FACILITY - SAFIR2018safir2018.vtt.fi/finalseminar/22032019/1_2_INTEGRA.pdf · § Pressure, differential pressure, flow transducers, and K-type thermocouples § Facility

PASSIVE HEAT REMOVAL TEST FACILITY - PASI

7INTEGRA SAFIR2018 - Final seminar 21.-22.3.2019

Maximum pressure 5 bar

Maximum temperature 170 °C

Heat exchanger height 2,8 m

Heat exchange tubes 15

Heat exchanger tube size Ø38 x 3

Riser pipe size Ø114,3 x 2,6

Downcomer size Ø88,9 x 3

Page 8: PASI TEST FACILITY - SAFIR2018safir2018.vtt.fi/finalseminar/22032019/1_2_INTEGRA.pdf · § Pressure, differential pressure, flow transducers, and K-type thermocouples § Facility

§ Model of one AES-2006 PHRS-Csystem heat removal loop

§ Simulation of natural circulation§ Model heat transfer as accurately as

possible§ Maintain relative gravitational and

frictional pressure losses§ Height scale 1:2 (laboratory space

restrictions)

SCALING

8INTEGRA SAFIR2018 - Final seminar 21.-22.3.2019

Page 9: PASI TEST FACILITY - SAFIR2018safir2018.vtt.fi/finalseminar/22032019/1_2_INTEGRA.pdf · § Pressure, differential pressure, flow transducers, and K-type thermocouples § Facility

§ Not a scaled down version of anycontainment building

§ Rated for the pressure of 5 bar and thefluid temperature of 170 ºC

§ Hot collector, riser pipeline inlet and themain parts of the heat exchange tubebundle are inside the vessel

§ Steam injection system§ Condensate water draining system§ Aerosol injection system can be added to

the system in future

FACILITY PARTS - PRESSURE VESSELSIMULATING CONTAINMENT CONDITIONS

9INTEGRA SAFIR2018 - Final seminar 21.-22.3.2019

Page 10: PASI TEST FACILITY - SAFIR2018safir2018.vtt.fi/finalseminar/22032019/1_2_INTEGRA.pdf · § Pressure, differential pressure, flow transducers, and K-type thermocouples § Facility

§ 15 heat exchange tubes andcold and hot collector drums

§ Mainly inside the vesselsimulating containmentconditions

§ Cold collector and the inlets ofthe heat exchange tubes arebelow the vessel− possible needs for future

instrumentation

FACILITY PARTS - HEAT EXCHANGER

10INTEGRA SAFIR2018 - Final seminar 21.-22.3.2019

Page 11: PASI TEST FACILITY - SAFIR2018safir2018.vtt.fi/finalseminar/22032019/1_2_INTEGRA.pdf · § Pressure, differential pressure, flow transducers, and K-type thermocouples § Facility

§ Pressure, differentialpressure, flow transducers,and K-type thermocouples

§ Facility includes capillarypiping to house fiber-optictransducers for longitudinaltemperature distributionmeasurements

INSTRUMENTATION

11INTEGRA SAFIR2018 - Final seminar 21.-22.3.2019

Page 12: PASI TEST FACILITY - SAFIR2018safir2018.vtt.fi/finalseminar/22032019/1_2_INTEGRA.pdf · § Pressure, differential pressure, flow transducers, and K-type thermocouples § Facility

§ Pressure and heat losses§ Natural circulation and general

behavior− transfers heat to the water

pool efficiently− steady operation on single-

phase flow− flow oscillations on two-

phase flow

CHARACTERIZING TESTS

12INTEGRA SAFIR2018 - Final seminar 21.-22.3.2019

Page 13: PASI TEST FACILITY - SAFIR2018safir2018.vtt.fi/finalseminar/22032019/1_2_INTEGRA.pdf · § Pressure, differential pressure, flow transducers, and K-type thermocouples § Facility

§ INTEGRA PROJECT− Carefully designed experiments are the most reliable way to obtain

fundamental understanding and reliable data of the phenomena− Data can be used in the development and validation of computer

codes for the safety analyses of nuclear power plants§ PASI TEST FACILITY

− Goal is to detect issues that could disturb the operation of a passivesystem or prevent it from functioning as designed

− PASI facility enables solving passive containment cooling systemrelated problems that occurs in the Finnish NPPs at short notice

CONCLUSIONS

13INTEGRA SAFIR2018 - Final seminar 21.-22.3.2019

Page 14: PASI TEST FACILITY - SAFIR2018safir2018.vtt.fi/finalseminar/22032019/1_2_INTEGRA.pdf · § Pressure, differential pressure, flow transducers, and K-type thermocouples § Facility

LUTCAMPUSAREA

INTEGRA SAFIR2018 - Final seminar 21.-22.3.2019 14