partnered hybrid a/c...
TRANSCRIPT
Overview
Who we are
What is ThermX
The part ThermX plays
How ThermX saves
Evaluation data
What our customers
say
Q&AInstallation & Application
Italy
Collective European‐American innovation covering heating, refrigeration & air temperature control
Who we are…
Innovation Development Operation Engineering
Increasing efficiencies of existing systems by up to 70%
HQ based in Manchester, Lancashire, UK Solar Thermal solutions for both Air Conditioning and
Refrigeration, produced for medium to large business corporations Over 6,000 commercial installations worldwide, retrofitted onto
most existing industry leading technologies
Who we are…
International Patent Pending Technology
Intellectual Property Protection – all our products using Solar Thermal and/or other third party heat exchangers between the compressor and the condenser are internationally patent pending. We will, without hesitation commence litigation with any company or individual attempting any type of IP infringement of our technologies.
What is Solar Refrigeration?
• A thermodynamic collection system
What it is not…
• …Solar Photovoltaic (PV)
Example: Testing in pure like for like environment conditions, in order to reproduce the average energy saved on a standard commercial 9 ton (cooling capacity) refrigeration system using Solar PV technology – it would require an average of between 30 & 40 250w Solar PV panels.
=
The illustration below shows the standard process when the system is in cooling mode.
Without sun
With sun
6.50
4.50
26kW
VRF
System
4.58
3.29
14kW
Mini V
RF
System
Example EER’s
EER’s
The facts are, regardless of the compressor in use…
• DC Inverter• Super DC Inverter• Hyper DC Inverter• Staged Compression• Digital Scroll…
…on average 80% of the energy on all systems is consumed by the compressor alone.
Compressor energy consumption
The general engineering make up the system is designed to produce fluctuating loads, subject to the systems requirement.Therefore when the load requirement is low, the compressor will logically run at low speed.
Subsequently, when the ambient temperature increases and therefore load requirement is high, the system increases its load capacity, therefore substantially increasing the energy consumption of the compressor.
Inverter systems
The hotter it gets, the harder this system works
The ThermX collector heats up the refrigerant, and boosts by that the cooling capacity
Collector Compressor Condenser
Expansion valve
Evaporator
The collector• Heats up the refrigerant• Refrigerant is gaseous
The ideal gas law applies• p * V = n * R * T• The higher temperature is converted into a higher mass flow in the evaporator, what means higher cooling capacity
• The condenser can due to the increased delta T (refrigerant to ambient tremperature) the heat transfer even better
For more details see our special documentations, how it works
ThermX increases the compressor’s capacity
ThermX increases the capacity of the compresser (variable) by using solar energy.The system’s logic converts that into a lower electrical consumption and – important !! –by keeping up the original cooling capacity at the same time
=+
Inverter System
The hotter it gets, the less the compressor works
The secret is in the collector and the system, the air conditioners are 99% standard
Air conditioner 99% standard
Special collector
• For refrigerants• High pressure (40 bar)• High efficiency
• Compressors with variable mass flow DC Inverter Fixed speed with Variators 2 and more compressors in parellel
• Special control logic
ThermX works with many systems – Air Conditioning and Refrigeration – all temperatures, all refrigerants
TypesSpecial collector
• Air conditioning Single Split (DC Inverter) Multi Split (DC Inverter) VRF Chillers Rooftops
• Refrigeration (supermarkets, cool chains) All temperatures All refrigerants (incl. NH3)
• For refrigerants• High pressure (40 bar)• High efficiency
Air conditioning
Cloudy Skies
Sunny Skies
6.50
4.50
26kW
VRF
System
4.58
3.29
14kW
Mini V
RF
System
Example EER’s
“At the time the ambient temperature begins to warm‐up around 8:00 am, the power of the machine starts a surprising decline, and remains there throughout the day’s hottest phase.” ‐ Chief Engineer ‐Pizza Hut
6‐months test results 63% ‐
‐ British Military of Defence 61%
Process cooling plant 37% ‐
-
‐ ROI 18‐months
‐ Convenience stores 58%ROI
32‐months ‐
‐ ROI 29‐months
Saving
Saving
Saving
The below demonstrates the energy usage on a ThermX DC Inverter system, in comparison to an A+ rated DC Inverter system
A clear illustration of ‘the hotter it gets, the better it works’ – as importantly the increased energy consumption of the comparative system under the
same circumstances
STUDYCASE
The largest fresh bread manufacturer in Malta, boasting a wealth of high profile customers. As with most businesses in the sector, this facility consumes a vast amount of electricity on a number of applications including process cooling, freezing, refrigeration and comfort cooling throughout.
“I have to be honest, I was personally sceptical about the projected abilities of ThermX when first presented to me. However my son was completely the opposite, and convinced talked me with the testing. I am now very pleased he did, as we could have walked away from a fantastic opportunity!” - Chief Engineering Contractor, Golden Harvest
Solar ThermalAir conditoning
A commercial bakery in Malta saves with ThermX a 1/3 of its electricity costs
Data: Malta 2014
26
Location: Industrial bakery, Ice cream manufacturing in Malta• Air conditioning of a process room (ice cream) down to 18°C at an ambient temperature of 35°C
• A 200 kW unit with 5 staged compression• Annual consumption without collectors: 30 000 €• After optimization: 20 000 € p.a.• Savings during the day 45%, over 24h shift 30%
Savings ‐ 30 %No solar collector
May 2014
With ThermXMay 2015
All our air conditioners are heat pumps
Cloudy Skies
Sunny Skies
8.00
4.50
26kW
VRF
System
6.16
14kW
Mini V
RF
System
3.43
Example COP’s
Heat pumps
ThermX heat pumps are much better than gas heaters or heat recovery systems ‐more efficient and make the building more valuable ‐ and on top they may cool too, e.g. for a supermarket of 1 000 m²
Air conditioning• Gasheater do not comply
anymore with renewable laws in some countries, e.g Germany
• Air supply with heat recovery >50% recovery grade, high
electricity demand for blowers Rest by gas heater Higher investment costs for
systems and bigger ducts No cooling possible
• ThermX heat pump Air to air heat pump Efficiency increase due to
ThermX technology, Min SEER required = 4,2 > 3,5
Heating &cooling in 1 system Solution with lowest costs Building efficiency class A+
Example:German supermarket
Condenser
Solar Panel
Compressor
Retail end refrigeration system
Cooling for retail refrigeration
• All physical effects yield electricity savings of up to 70%
Retail Commercial refrigeration
STUDYCASE
“After retrofitting seven of our sites, they collectively reduced the energy consumption by 36%, therefore they were clearly the right partner for this new build project. So far they are producing results that are in line with their own projections and therefore well in line with our expectations”. Richard Cox, MD
Solar ThermalRefrigeration & Air conditoning
Middle East
British MOD, Cyprus Cable & Wireless, Bahamas
Italy Peterborough, UK
Cable & Wireless, BahamasBritish MOD, CyprusCake Factory, ItalyCummins, UK
Some of our installations in ItalyLa Spezia ‐ AcamSpa: Multisplit 12 kW – 4 indoor units
• Annual savings of 950 € for cooling and heating
• Savings of 34%
Conad – Marsala : retrofit of refrigeration for supermarket
• 3 compressors, with cooling capcity in 60 kW (24hp)
• Retrofit of 4 panels• Annual savings of 30%
Full new systems from us – collectors and air conditioners, refrigerators, chillers
Air conditioning
• Single splits: 1 outdoor to 1 indoor
• Multi: 1 up to 5 indoors
• VRFs: 1 up to 64 indoors
• Air conditioning for residential and commercial
• Single/Multi : Cooling/ heating capacity: 2,6 12 kW, 0.75 4 hp
• VRF 8 200 kW, 3 72 hp
With partners
ChillersRefrigeration
Affiliated or case by case partnership• LED Lighting • PV panels• Off grid installations• Rain water harvesting
• Outdoor unit with solar collector
• Cools/heats water for water running systems, air conditioning or process cooling
• Cooling and heating, evtl. with back‐up heater
• Heating capacity: 2 – 780 hp5 up to 2 000 kW
• Outdoor unit with solar collector, cabinet
• Cools food and beverages
• “Open door” cabinets in different sizes with cooling demand of 800‐900 Watt per cabinet
• Cooling capacity:20 ‐ 60 kW at different temperatures with or without integrated condenser
There are virtually no applications that ThermX can not partner with,
from process cooling…RETROFIT READY
Retrofit – our collectors for your existing systems
To Your own cooling system‐ Chillers‐ Larger rooftops‐ Refrigeration systems‐ VRF Systems, special type‐ No single/multi splits
‐ All Freons, ‐ Ammonia‐ R22 where allowed‐ Propane, CO2 on development road
+ +
+
• Reduce the electricity bill• Make utilities (electricity suppliers)
happier by less power drops • not a "me‐too" supplier of air conditioner
• Not competing over price
• low margin business
ThermX focus on your electricity bill
ThermX pays you back your investment
ThermX systems utilize solar energy and can pay back their investment through significant savings in energy (electricity or diesel)
Standard non‐solar systems don’t save much energy. Their today’s improvements in efficiency is marginal. Daikin cools now its PCB ‐ as in computers. They just consume and consumer and consume and consume and consume and
consume and consume and consume
ThermX saves you the money where you pay most –which are electricity costs during operation
100%
Savings from ThermX
Savings from buying cheapest product
50% savings from
ThermX
15% savings cheap unit
Standard Optimized
Ratio 1: 13
Where to save
10 years, commerical applications, Europe
Life cycle costs of air conditioners
Costs for Purchase&Installation
Costs for Purchase&Installation
Electricitycosts
Electricitycosts
Extreme attractive ROIs and payback rates of ThermX installations
ROI examplesROI examples
• South Europe (Italy/France/Spain) ROI: 1,6 ‐ 1,9 years, Invest fully paid back after 6 ‐ 8 years
• North Europe (UK/Germany) : ROI: 1,6 years, Invest fully paid back after 7 years
• Malta ROI: 1,5 years, Invest fully paid back after 6 years
• North Afrika ROI: 1,8 years, Invest fully paid back after 8 years
• Middle East: ROI: 1,8 years, Invest fully paid back after 8 years
10 years, commerical application, Europe
100%
Costs for Purchase&Installation
ROI < 2‐3 years:Additional investment for ThermX returned
Purchase price for ThermX returned
Cum
ulat
ed c
osts
years 10
Producing free natural energy – whatever the
temperature
External ambient temperature+26°F/‐3°C
Heat exchanger temperature
+260°F/+127°C