Page 1 of 14 ATI PANEL MOUNT VERSION 1) Panel Mount Enclosure Material: Aluminum, Black Anodized 2) Nema-4X Encloure Material: Base: Molded ABS, (tan in color) Cover: Clear Polycarbonate with dual hinge. 3) Nema-4X Rating: NEMA rated types 4,4X IEC 529 rated IP66 Flammibility Rating UL94 HB NOTES NEMA-4X VERSION 3.54" 89.9mm 6.10" 154.9mm 5.46" 138.7mm .34" 8.6mm 3.78" 96mm 3.78" 96mm Enclosure Dimensions ATI-0124 ATI-010 Model A15/76 Turbidity Monitor - SS-A1576, Rev-E (8/11)

Upload: others

Post on 05-Aug-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PANEL MOUNT VERSION A15-76 Turbidity Monitor...ATI-0241 Model A15/76 Turbidity Monitor - Optional Equipment Dimensions RE (8/11) Page 3 of 14 ATI NOTES 1)Front of panel is NEMA 1,

Page 1 of 14

ATI

PANEL MOUNT VERSION

1) Panel Mount Enclosure Material:Aluminum, Black Anodized

2) Nema-4X Encloure Material:Base: Molded ABS, (tan in color)Cover: Clear Polycarbonate with

dual hinge.

3) Nema-4X Rating:

NEMA rated types 4,4XIEC 529 rated IP66Flammibility Rating UL94 HB

NOTESNEMA-4X VERSION

3.54"89.9mm

6.10"154.9mm

5.46"138.7mm.34"

8.6mm

3.78"96mm

3.78"96mm

Enclosure Dimensions

ATI-0124

ATI-010

Model A15/76 Turbidity Monitor -

SS-A1576, Rev-E (8/11)

Page 2: PANEL MOUNT VERSION A15-76 Turbidity Monitor...ATI-0241 Model A15/76 Turbidity Monitor - Optional Equipment Dimensions RE (8/11) Page 3 of 14 ATI NOTES 1)Front of panel is NEMA 1,

Page 2 of 14

ATI

NOTESJUNCTION BOX

1) Nema-4X Encloure Material:Molded FRP (Fiberglas reinforcedpolyester),gray in color.

2) Nema-4X Rating:

UL listed per std. 508CSA certified per std. C22.2 No. 94NEMA rated types 4,4X,6,6P,12,13CEMA rated types 2,3,4 and 5IEC 529 rated IP 67-11

3) Mounting Dimensions:

3.11" [79mm] x 3.11" [79mm]

4) Part No. 00-0726.

ATI-0241

Optional Equipment DimensionsModel A15/76 Turbidity Monitor -

RE (8/11)

Page 3: PANEL MOUNT VERSION A15-76 Turbidity Monitor...ATI-0241 Model A15/76 Turbidity Monitor - Optional Equipment Dimensions RE (8/11) Page 3 of 14 ATI NOTES 1)Front of panel is NEMA 1,

Page 3 of 14

ATI

NOTES

1) Front of panel is NEMA 1, general purposeonly.

2) Panel mounting clips supplied with monitor.

3.60"91.4mm

3.60"91.4mm

MOUNTING CLIPS(2 PER UNIT)PANEL CUT-OUT

WALL MOUNT - NEMA-4X

HANDRAIL MOUNT - NEMA-4X

1) Wall mounting requires customer suppliedscrews or bolts.

1) All listed hardware is supplied as part ofhandrail mounting kit # 00-0139.

PANEL MOUNT

Installation Diagrams

ATI-0125

ATI-0126

ATI-043

Model A15/76 Turbidity Monitor -

RE (8/11)

Page 4: PANEL MOUNT VERSION A15-76 Turbidity Monitor...ATI-0241 Model A15/76 Turbidity Monitor - Optional Equipment Dimensions RE (8/11) Page 3 of 14 ATI NOTES 1)Front of panel is NEMA 1,

Page 4 of 14

ATI

A15/76 TURBIDITY MONITOR (VAC) ELECTRICAL CONNECTIONS

A15/76 TURBIDITY MONITOR(BACK VIEW)

ATI-0443

Terminal Block DesignationsModel A15/76 Turbidity Monitor -

RE (8/11)

Page 5: PANEL MOUNT VERSION A15-76 Turbidity Monitor...ATI-0241 Model A15/76 Turbidity Monitor - Optional Equipment Dimensions RE (8/11) Page 3 of 14 ATI NOTES 1)Front of panel is NEMA 1,

Page 5 of 14

ATI

A15/76 TURBIDITY MONITOR (VDC) ELECTRICAL CONNECTIONS

A15/76 TURBIDITY MONITOR(BACK VIEW)

RE (8/11)

Page 6: PANEL MOUNT VERSION A15-76 Turbidity Monitor...ATI-0241 Model A15/76 Turbidity Monitor - Optional Equipment Dimensions RE (8/11) Page 3 of 14 ATI NOTES 1)Front of panel is NEMA 1,

Page 6 of 14

ATI

SYSTEM WIRING DIAGRAM w/OPTIONAL JUNCTION BOX

ATI-0445

Model A15/76 Turbidity Monitor -

RE (8/11)

Wiring Diagrams

Page 7: PANEL MOUNT VERSION A15-76 Turbidity Monitor...ATI-0241 Model A15/76 Turbidity Monitor - Optional Equipment Dimensions RE (8/11) Page 3 of 14 ATI NOTES 1)Front of panel is NEMA 1,

Page 7 of 14

ATI

FLOW SENSOR DIMENSIONS

Sensor Dimensions and Installation

ATI-0434

FLOWCELL DIMENSIONS

ATI-0435

Model A15/76 Turbidity Monitor -

RE (8/11)

Page 8: PANEL MOUNT VERSION A15-76 Turbidity Monitor...ATI-0241 Model A15/76 Turbidity Monitor - Optional Equipment Dimensions RE (8/11) Page 3 of 14 ATI NOTES 1)Front of panel is NEMA 1,

Page 8 of 14

ATI

FLOWSENSOR/FLOWCELL INSTALLATION DRAWING

Sensor Dimensions and Installation

ATI-0444

Installation of flowcell must be done Horizontally as shown above.

Model A15/76 Turbidity Monitor -

RE (8/11)

Page 9: PANEL MOUNT VERSION A15-76 Turbidity Monitor...ATI-0241 Model A15/76 Turbidity Monitor - Optional Equipment Dimensions RE (8/11) Page 3 of 14 ATI NOTES 1)Front of panel is NEMA 1,

Page 9 of 14

ATI Sensor Installation

TURBIDITY SENSOR 1½ FLOW TEE ASSEMBLY

VERTICAL CONFIGURATION IS RECOMMENDEDBUT HORIZONTAL CONFIGURATION IS ACCEPTABLE,PROVIDED SENSOR IS MOUNTED IN THE 3:00 OR 9:00POSITION.

ATI-0542

Model A15/76 Turbidity Monitor -

RE (8/11)

Page 10: PANEL MOUNT VERSION A15-76 Turbidity Monitor...ATI-0241 Model A15/76 Turbidity Monitor - Optional Equipment Dimensions RE (8/11) Page 3 of 14 ATI NOTES 1)Front of panel is NEMA 1,

Page 10 of 14

ATI Sensor Installation

FLOW "T" RECOMMENDED PIPING

ATI-0513

Model A15/76 Turbidity Monitor -

RE (8/11)

Page 11: PANEL MOUNT VERSION A15-76 Turbidity Monitor...ATI-0241 Model A15/76 Turbidity Monitor - Optional Equipment Dimensions RE (8/11) Page 3 of 14 ATI NOTES 1)Front of panel is NEMA 1,

Page 11 of 14

ATI

RE (8/11)

D15/76 AUTO-CLEAN TURBIDITY MONITOR

1) Nema-4X Encloure Material:Base: Molded ABS, Tan in ColorCover: Clear Lexan w/Dual Hinge

2) Nema-4X Rating:Nema rated types 4, 4XIEC 529 rated IP66

3) Sensor Material:Noryl EN265 & Stainless Steel

NOTES

AUTO-CLEAN TURBIDITY SENSOR

Dimensions

ATI-0553

ATI-0473

Model D15-76 Auto-Clean Turbidity Monitor -

Page 12: PANEL MOUNT VERSION A15-76 Turbidity Monitor...ATI-0241 Model A15/76 Turbidity Monitor - Optional Equipment Dimensions RE (8/11) Page 3 of 14 ATI NOTES 1)Front of panel is NEMA 1,

Page 12 of 14

ATI

NOTESMONITOR HANDRAIL INSTALLATION

1) Always mount sensor cleaner within 25 ft. ofsensor if possible. Maximum air line distanceis 50 ft.

2) Sun shade over monitor is recommended inhot climates.

3) Monitor Handrail Mounting Kit # 00-0930supplies all hardware listed for mountingmonitor.

4) Wall mounting requires customer suppliedscrews or bolts.

5) Sensor Pipe Mounting Kit # 00-0624 suppliesmounting plate with hardware and PVC pipemounting adaptor.

6) Sensor Pipe Mounting Kit with Rag Shedder# 00-0629 supplies mounting plate withhardware and PVC rag shedder.

SENSOR HANDRAIL INSTALLATION

RE (8/11)

Installation Diagrams

ATI-0490

Model D15-76 Auto-Clean Turbidity Monitor -

Page 13: PANEL MOUNT VERSION A15-76 Turbidity Monitor...ATI-0241 Model A15/76 Turbidity Monitor - Optional Equipment Dimensions RE (8/11) Page 3 of 14 ATI NOTES 1)Front of panel is NEMA 1,

Page 13 of 14

ATI

STANDARD SYSTEM WIRING DIAGRAM

RE (8/11)

System Interconnections

ATI-0534

Model D15-76 Auto-Clean Turbidity Monitor -

Page 14: PANEL MOUNT VERSION A15-76 Turbidity Monitor...ATI-0241 Model A15/76 Turbidity Monitor - Optional Equipment Dimensions RE (8/11) Page 3 of 14 ATI NOTES 1)Front of panel is NEMA 1,

Page 14 of 14

ATI

REMOTE MONITOR WIRING DIAGRAM

RE (8/11)

System Interconnection

ATI-0536

Model D15-76 Auto-Clean Turbidity Monitor -