RP 6.1.2.8-2Page 1
R E N E W A L P A R T S B U L L E T I N
LOW-VOLTAGEPOWER CIRCUIT BREAKERS
Type K-225 through 2000 and K-600S through 2000SK600M through 2000M
Type K-Don 600 through 1600 and K-Don 600S through 1600SK-Don 600M through 1600M
RENEWAL PARTS
RP 6.1.2.8-2 Page 2
R E N E W A L P A R T S B U L L E T I N
Type K-225, 600, 800, 1600, 2000, 600S, 800S, 1600S, 2000S, 600M, 800M, 1600M, 2000MType K-Don-600, 800, 1600, 600S, 800S, 1600S, 600M, 800M, 1600M FUSED CIRCUIT BREAKERS
1. Recommended quantities are as follows:
Domestic - One (1) complete set for each ten (10) breakers or fraction thereofinstalled for each rating.
International - One (1) complete set for each five (5) breaker or fraction thereofinstalled for each rating.
NOTE: Figure Reference parts marked with delta (∆ ) are minimum that shouldbe ordered for normal duty applications. For heavy-duty applications,all applicable Figure Reference parts should be ordered.
2. The parts listed cover an indefinite period of time. With normal duty andmaintenance, replacement will be infrequent.
3. Standard hardware (screws, nuts, lockwasher, etc.) is not included with the parts.
4. Where continuity of service is mandatory, a spare breaker is recommended
When ordering, always state type of circuit breaker and serial number from breakernameplate in addition to part description and ordering number. State the quantity,description, and ordering number of each assembly or part required, as applicable.
EXAMPLE: To order moving contact assemblies for a typical K-600 circuit breaker,provide the following:
For a type K-600 circuit breakerSerial No.39402-22-2-4A (From breaker nameplate)S.O. 33-39402Quantity-2 (Fig. Reg. 4B, page 8) Moving Contact Assemblies 706783T02
The recommended spares in this bulletin apply only to circuit breakers having thefeatures listed. For example, if your circuit breaker is stationary mounted, you woulddisregard the primary and secondary disconnect assemblies (Fig. Ref., 27A,B,C,D,E,and 28). If your circuit breaker has some special feature not listed, provide completedescription of feature, such as - Shunt Trip - 120 Volts AC, in addition to otherinformation requested in example above.
When ordering current-limiting fuses, always specify the continuous current rating inaddition to the ordering number.
NOTE: Fig. Ref. parts marked with a bullet (•). On circuit breakers equipped with solidstate overcurrent trip devices, as designated by the “S” at the end of the circuitbreaker “Type”, it is necessary to replace both the solid state logic assemblyand the lower molding assembly when changing the circuit breaker to a newAMPERE TAP range.
General Notes
OrderingInstructions
RP 6.1.2.8-2Page 3
MPSC-2000 trip device
Barrier – 6A
D.O Bar & Gear Box Assy - 22
Operating Mechanical Assy 11A
Escutcheon Front Plate – 24A
Dust Plate - 23
Arc Chute Assy – 1A
Ground Clip - 34
Primary Disconnect Assy – 27B
Upper Molding Assy – 5A
RP 6.1.2.8-2 Page 4
R E N E W A L P A R T S B U L L E T I N
Lower Base Moldingw/O/C Trip Device
(Standard Type OD-3 Electro-Mechanical Trip Devices)
(Specified Ampere Rating.)1
20 Amp 7A 1 1215OVCT30240 Amp 7A 1 1215OVCT30470 Amp 7A 1 1215OVCT307
125 Amp 7A 1 1215OVCT312225 Amp 7A 1 1215OVCT322
Lower Molding, OD-3Overcurrent, K600 Kdon600
40 Amp 7A 1 1 1225OVCT30470 Amp 7A 1 1 1225OVCT307
125 Amp 7A 1 1 1225OVCT312225 Amp 7A 1 1 1225OVCT322400 Amp 7A 1 1 1225OVCT340600 Amp 7A 1 1 1225OVCT360225 Amp 7B 3 3 1235OVCT322400 Amp 7B 3 3 1225OVCT340800 Amp 7B 3 3 1235OVCT380
1600 Amp 7B 3 3 1235OVCT316400 Amp 7B 3 1245OVCT340800 Amp 7B 3 1245OVCT380
1600 Amp 7B 3 1245OVCT3162000 Amp 7B 3 1245OVCT320
Lower Molding, OD-3Overcurrent, K800 Kdon800
125 Amp 7A 1 1 1285OVCT312225 Amp 7A 1 1 1285OVCT322400 Amp 7A 1 1 1285OVCT340800 Amp 7A 1 1 1285OVCT380
Lower Base Moldingw/Ph. & Pwr. Sensors
50 to 225 Amp 8A 1 1 709733T13250 to 600 Amp 8A 1 1 709733T14300 to 800 Amp 8A 1 1 709733T12250 to 600 Amp 8B 3 709734T03
600 to 1600 Amp 8B 3 709734T01250 to 600 Amp 8B 3 3 709734T06
600 to 1600 Amp 8B 3 3 709734T05800 to 2000 Amp 8B 3 3 709734T05
Power Shield(Standard Type SS-3)2
50 to 225 Anp 9 1 1 609901T003250 to 600 Amp 9 1 1 1 1 1 609902T003300 to 800 Amp 9 1 1 609907T003
600 to 1600 Amp 9 1 1 1 609903T003800 to 2000 Amp 9 1 609904T003
Quantity per 3 pole breaker
Description ofAssembly or Part K
-Do
n 60
0S/8
00S
K-D
on
1600
K-D
on
600/
800
K20
00S
K16
00S
K60
0S/K
800S
K20
00
K16
00
K60
0-K
800
K22
5
K-D
on
1600
S
Fig.Ref.
OrderingNumber
RP 6.1.2.8-2 Page 5
R E N E W A L P A R T S B U L L E T I N
SS Trip Device Test Set(Type 504) 10 1 1 1 1 1 608089T01
Operating Mech Assembly(M.O. Stationary)3 11A 1 1 1 1 1 709774T01
Operating Mech Assembly(M.O. Stationary) 11A 1 1 1 1 1 1 709774T05
Operating Mech Assembly(M.O. Drawout)3 11A 1 1 1 1 1 709774T02
Operating Mech Assembly(M.O. Drawout) 11A 1 1 1 1 1 1 709774T06
Operating Mech Assembly(E.O. Stationary)3 11B 1 1 1 1 1 709774T03
Operating Mech Assembly(E.O. Stationary) 11B 1 1 1 1 1 1 709774T07
Operating Mech Assembly(E.O. Drawout)3 11B 1 1 1 1 1 709774T04
Operating Mech Assembly(E.O. Drawout) 11B 1 1 1 1 1 1 709774T08
∆ Motor Assembly(When Used)4
48 Volts DC 12 1 1 1 1 1 1 1 1 1 1 1 709799T03110/120V AC or 125V DC 12 1 1 1 1 1 1 1 1 1 1 1 709799T01208/240V AC or 250V DC 12 1 1 1 1 1 1 1 1 1 1 1 709799T02
∆ Control Device Assembly(When Used)110/120V AC 13 1 1 1 1 1 1 1 1 1 1 1 708392T09208/240V AC 13 1 1 1 1 1 1 1 1 1 1 1 708392T16
48V DC 13 1 1 1 1 1 1 1 1 1 1 1 708392T06125V DC 13 1 1 1 1 1 1 1 1 1 1 1 708392T07250V DC 13 1 1 1 1 1 1 1 1 1 1 1 708392T08
∆ Shunt Trip Assembly(When Used)110/120V AC 14A 1 1 1 1 1 1 1 1 1 708393T12208/240V AC 14A 1 1 1 1 1 1 1 1 1 708393T10360/480V AC 14A 1 1 1 1 1 1 1 1 1 708393T11500/600V AC 14A 1 1 1 1 1 1 1 1 1 708393T08
48V DC 14A 1 1 1 1 1 1 1 1 1 708393T06125V DC 14A 1 1 1 1 1 1 1 1 1 708393T07250V DC 14A 1 1 1 1 1 1 1 1 1 708393T08
Quantity per 3 pole breaker
Description ofAssembly or Part K
-Do
n 60
0S/8
00S
K-D
on
1600
K-D
on
600/
800
K20
00S
K16
00S
K60
0S/K
800S
K20
00
K16
00
K60
0-K
800
K22
5
K-D
on
1600
S
Fig.Ref.
OrderingNumber
RP 6.1.2.8-2 Page 6
R E N E W A L P A R T S B U L L E T I N
Quantity per 3 pole breaker
Description ofAssembly or Part K
-Do
n 60
0S/8
00S
K-D
on
1600
K-D
on
600/
800
K20
00S
K16
00S
K60
0S/K
800S
K20
00
K16
00
K60
0-K
800
K22
5
K-D
on
1600
S
Fig.Ref.
OrderingNumber
∆ Shunt Trip Assembly(When Used)110/120V AC 14B 1 1 1 1 1 1 1 1 1 709723T12208/240V AC 14B 1 1 1 1 1 1 1 1 1 709723T10360/480V AC 14B 1 1 1 1 1 1 1 1 1 709723T11500/600V AC 14B 1 1 1 1 1 1 1 1 1 709723T08
48V DC 14B 1 1 1 1 1 1 1 1 1 709723T06125V DC 14B 1 1 1 1 1 1 1 1 1 709723T07250V DC 14B 1 1 1 1 1 1 1 1 1 709723T08
∆ Motor Assembly(When Used) (Ryobi)4
48 Volts DC 43 1 1 1 1 1 716601T03110/120V AC or 125V DC 43 1 1 1 1 1 716601T01208/240V AC or 250V DC 43 1 1 1 1 1 716601T02
48 Volts DC 43 1 1 1 1 1 1 716601T06110/120V AC or 125V DC 43 1 1 1 1 1 1 716601T04208/240V AC or 250V DC 43 1 1 1 1 1 1 716601T05
∆ Magnetic Latch Assembly 15 1 1 1 1 1 160862T03
∆ Undervoltage Trip Device-Inst (When Used)
110/120V AC 16A 1 1 1 1 1 1 1 1 1 1 1 708472T01208/240V AC 16A 1 1 1 1 1 1 1 1 1 1 1 708472T02360/480V AC 16A 1 1 1 1 1 1 1 1 1 1 1 708472T04500/600V AC 16A 1 1 1 1 1 1 1 1 1 1 1 708472T05
48V DC 16A 1 1 1 1 1 1 1 1 1 1 1 708472T06125V DC 16A 1 1 1 1 1 1 1 1 1 1 1 708472T07250V DC 16A 1 1 1 1 1 1 1 1 1 1 1 708472T08
∆ Undervoltage Trip Device -Time Delay (When Used)
110/120V AC 16B 1 1 1 1 1 1 1 1 1 1 1 708472T09208/240V AC 16B 1 1 1 1 1 1 1 1 1 1 1 708472T10360/480V AC 16B 1 1 1 1 1 1 1 1 1 1 1 708472T12500/600V AC 16B 1 1 1 1 1 1 1 1 1 1 1 708472T13
48V DC 16B 1 1 1 1 1 1 1 1 1 1 1 708472T14125V DC 16B 1 1 1 1 1 1 1 1 1 1 1 708472T15250V DC 16B 1 1 1 1 1 1 1 1 1 1 1 708472T16
Open Fuse Trip Device 17 1 1 1 1 709724T01
Operation Counter(When Used) 18 1 1 1 1 1 1 1 1 1 1 1 180522C00
Motor Disconnect Switch(When Used) 19 1 1 1 1 1 1 1 1 1 1 1 715668A00
Electrical Close Switch(When Used) 20 1 1 1 1 1 1 1 1 1 1 1 716100C00
Opening Spring 21 2 2 2 2 2 650220A06
Opening Spring 21 2 2 2 2 2 2 650220A07
RP 6.1.2.8-2 Page 7
R E N E W A L P A R T S B U L L E T I N
Quantity per 3 pole breaker
Description ofAssembly or Part K
-Do
n 60
0S/8
00S
K-D
on
1600
K-D
on
600/
800
K20
00S
K16
00S
K60
0S/K
800S
K20
00
K16
00
K60
0-K
800
K22
5
K-D
on
1600
S
Fig.Ref.
OrderingNumber
Drawout MechanismAssembly 22 1 1 1 1 1 703230T15
Drawout MechanismAssembly 22 1 1 1 1 1 1 703230T16
Dust Plate 23 1 1 1 1 1 1 1 1 1 1 1 702669A00
Escutcheon FrontPlate Assembly
M.O. - Stationary 24A 1 1 1 1 1 1 1 1 1 1 1 708118K01M.O. - Drawout 24A 1 1 1 1 1 1 1 1 1 1 1 708118K02
E.O. - Stationary 24B 1 1 1 1 1 1 1 1 1 1 1 708119K03E.O. - Drawout 24B 1 1 1 1 1 1 1 1 1 1 1 708119K04
Basic Frame Assembly 1 1 1 708356T01
Basic Frame Assembly 1 1 1 708356T03
Basic Frame Assembly 1 1 1 1 1 1 708356T05
Basic Breaker Assembly 1 708355T01
Basic Breaker Assembly 1 1 1 1 708355T03
Basic Breaker Assembly 1 1 1 1 708355T05
Basic Breaker Assembly 1 1 1 708355T07
Primary DisconnectAssembly (When Used) 27A 6 706777T01
Primary DisconnectAssembly (When Used) 27B 6 6 3 3 706777T03
Primary DisconnectAssembly (When Used) 27C 3 3 706777T05
Primary DisconnectAssembly (When Used) 27D 6 6 706777T11
Primary DisconnectAssembly (When Used) 27E 6 6 6 6 709957T01
Secondary DisconnectAssembly-Moving 28 2 2 2 2 2 2 2 2 2 2 2 703153K01
Secondary DisconnectAssembly-Stationary 29 2 2 2 2 2 2 2 2 2 2 2 271985T01
∆ Current Limiting Fuse(When Used)
300 Amp (Non-UL) 30A 3 3 3 710316A01400 Amp (Non-UL) 30A 3 3 3 710316A02600 Amp (Non UL) 30A 3 3 3 3 710316A03
800 Amp (UL) 30A 3 3 3 3 710316A041000 Amp (UL) 30A 3 3 3 3 710316A051200 Amp (UL) 30A 3 3 3 3 710316A061600 Amp (UL) 30A 3 3 710316A072000 Amp (UL) 30A 3 3 710316A082500 Amp (UL) 30A 3 3 712652A00
RP 6.1.2.8-2 Page 8
R E N E W A L P A R T S B U L L E T I N
Quantity per 3 pole breaker
Description ofAssembly or Part K
-Do
n 60
0S/8
00S
K-D
on
1600
K-D
on
600/
800
K20
00S
K16
00S
K60
0S/K
800S
K20
00
K16
00
K60
0-K
800
K22
5
K-D
on
1600
S
Fig.Ref.
OrderingNumber
Auxiliary Switch - 4 Contact 31 1 1 1 1 1 1 1 1 1 1 1 700034K01
Auxiliary Switch- 8 Contact 32 1 1 1 1 1 1 1 1 1 1 1 700038K01
Auxiliary Switch w/mounting4 Contact - RH 33 1 1 1 1 1 709653T018 Contact - RH 33 1 1 1 1 1 709653T024 Contact - LH 33 1 1 1 1 1 709653T03
4 Cont.-LH & 4 Cont.-RH(As Shown) 33 1 1 1 1 1 709653T04
4 Cont.-LH & 8 Cont.-RH 33 1 1 1 1 1 709653T054 Contact - RH 33 1 1 1 1 1 1 709653T068 Contact - RH 33 1 1 1 1 1 1 709653T074 Contact - LH 33 1 1 1 1 1 1 709653T08
4 Cont.-LH & 4 Cont.-RH 33 1 1 1 1 1 1 709653T094 Cont.-LH & 8 Cont.-RH 33 1 1 1 1 1 1 709653T10
Ground Clip 34 1 1 1 1 1 1 1 1 1 1 1 703230T03
Hardware & Retainer Kit 35 1 1 1 1 1 1 1 1 1 1 1 709654T02
Circuit Breaker Accessories(Order Accessories in
quantities as required)Accessory Kit 36 709770T01
Maintenance Handle 37 716664T01Lifting Yoke 38 709770T05
Racking Crank 39 711706K03
Arc Chute Assembly 1A 3 3 3 3 3 706775T13
Arc Chute Assembly 1B 3 3 3 3 3 3 706775T12
Arc Chute Retainer 2A 2 2 2 2 2 701496A00
Arc Chute Retainer 2B 2 2 2 2 2 2 701543A00
Upper Base Molding w/Stationary Contact Assembly 3A 1 706784T01
Upper Base Molding w/Stationary Contact Assembly 3A 1 1 1 1 706784T03
Upper Base Molding w/Stationary Contact Assembly 3B 3 3 706784T05
Upper Base Molding w/Stationary Contact Assembly 3B 3 3 3 3 706784T06
Moving Contact Assembly 4A 3 706783T01
Moving Contact Assembly 4B 3 3 3 3 706783T02
Moving Contact Assembly 4C 3 3 3 3 706783T03
Moving Contact Assembly 4C 3 3 706783T07
Upper Base Molding w/Stationary & Moving Contacts 5A 1 706782T01
RP 6.1.2.8-2 Page 9
R E N E W A L P A R T S B U L L E T I N
Quantity per 3 pole breaker
Description ofAssembly or Part K
-Do
n 60
0S/8
00S
K-D
on
1600
K-D
on
600/
800
K20
00S
K16
00S
K60
0S/K
800S
K20
00
K16
00
K60
0-K
800
K22
5
K-D
on
1600
S
Fig.Ref.
OrderingNumber
Upper Base Molding w/Stationary & Moving Contacts 5A 1 1 1 1 706782T03
Upper Base Molding w/Stationary & Moving Contacts 5B 3 3 706782T05
Upper Base Molding w/Stationary & Moving Contacts 5B 3 3 3 3 706782T06
Inter-phase Barrier 6A 4 4 4 4 4 701531A00
Inter-phase Barrier 6B 3 3 3 707110A00
Inter-phase Barrier 6C 3 3 3 710524A00
Lower Base Moldingw/Ph.&Pwr Sensors
(Standard Type MPSC-2000Microprocessor-Base
Trip Device)200 Amp 40 1 1 709733T03600 Amp 40 1 1 709733T04800 Amp 40 1 1 709733T01200 Amp 41 3 709734T14800 Amp 41 3 709734T08
1600 Amp 41 3 709734T02800 Amp 41 3 709734T13
1600 Amp 41 3 709734T071600 Amp 41 3 709734T072000 Amp 41 3 709734T04
MPSC-2000 Trip Device5
200 Amp 42 1 1 716666T01600 Amp 42 1 1 716666T10800 Amp 42 1 1 716666T02200 Amp 42 1 716666T01800 Amp 42 1 716666T02
1600 Amp 42 1 716666T03800 Amp 42 1 716666T02
1600 Amp 42 1 716666T031600 Amp 42 1 716666T032000 Amp 42 1 716666T04
MPSC Trip Device Test Set 1 1 1 1 1
1Basic OD-3 Overcurrent listed, for OD-4, OD-5, OD-6 etc. refer to Components Sales - NADSG2Basic (Phase only) Power Shield, for SS-4, SS-5, SS-7, etc. and for target or alarm option adders, refer to Components Sales - NADSG3Replacement of motor assembly may require replacement of complete operating mechanism assembly. Refer to Components Sales - NADSG4Operating mechanism shown are not to be used as replacement on breakers equipped with Ryobi type motor; Refer to Component Sales - NADSG5Basic 3w Ground application MPSC-2000. For 4w Ground, Voltage Interface Module and Instantaneous Lock-in options, etc. Refer to Component Sales - NADSG
RP 6.1.2.8-2Page 10
1B
1A
2A
2B
3A
RP 6.1.2.8-2Page 11
4B
3B4A 4B
4C5A
RP 6.1.2.8-2Page 12
5B5B
6A
6A
6C
RP 6.1.2.8-2Page 13
7A 7B
8A 8B
RP 6.1.2.8-2Page 14
9
11B
12
10
11A
11B
RP 6.1.2.8-2Page 15
14B13
14A
15 16A
16B17
RP 6.1.2.8-2Page16
18
19 20
21 22
2324A
RP 6.1.2.8-2Page 17
24B
27A
27B 27B
27D27E
RP 6.1.2.8-2Page 18
28
29
31
32
30A
RP 6.1.2.8-2Page 19
3334
35
33
RP 6.1.2.8-2Page 20
37
38
39
36
RP 6.1.2.8-2Page 21
4041
4243