packman group packman group 83 vertical steam boiler

3
Packman G r o u p General Catalog 82 Steam boiler room Vertical steam boiler Packman vertical steam boiler PSB series are designed with simple mechanical structure via modern machinery and equipment to to conform to the latest regulations of EN and DIN standards. The PSB series are user friendly, and use the latest technology to meet every customers needs. More info about this product. Scan this code to receive a 3D product file. Scan this code To access the Pakman product selection application and select this product.

Upload: others

Post on 15-Oct-2021

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Packman Group Packman Group 83 Vertical steam boiler

www packmangroup com. .Packman G r o u p General Catalog Packman G r o u p82 83

Ste

am b

oile

r ro

om

Vertical steam boiler

Packman vertical steam boiler PSB series are designed with simple mechanical

structure via modern machinery and equipment to to conform to the latest

regulations of EN and DIN standards.

The PSB series are user friendly, and use the latest technology to meet every

customers needs.

More info about this product.Scan this code to receive a 3D product file.

Scan this code To access the Pakman product selection application and select this product.

Ste

am b

oile

r ro

om

Boiler

exp

Product Capacity Calculation & Selection:

The Steam boiler selected based on maximum require capacity and type of process

The better way to select the capacity and pressure of the boiler is following below

steps:

1- Calculate the maximum heat load based on your process.

2- Adding 20% to maximum load for coefficient of confidence.

3- Consider the 80% average efficiency for vertical steam boiler.

4- Calculate pressure based on your project and distance between boiler and

consumer.

5- Determined the number of boiler you have: it is better you choose number of boiler

for 100% of full load

Finally you can select the model from the table in bellow.

The vertical steam boiler is robust and economical. The furnace is formed by the fire tube. The flue

gases are directed through topped smoke tubes .

Constructional design boiler is especially suitable for the combustion of liquid or gaseous fuels. It

can, however, as well be used for solid fuels. Coal or wood performances.

Fire tube:

The chosen diameter makes sure that an unobjectionable flame can develop and a complete

burnout is guaranteed. The decision whether plane or spiral fire tubes are to be used depends on

the diameter and the working pressure. The arrangement in the inferior part of the water space has

an especially favorable effect on the heat exchange and the water circulation, and allows a clear

arrangement of the remaining flue gas passes. Boiler supports, skids: The boiler body is based on

supports. Most of the unit are delivered on skids; by that special foundations for the installation are

not required. In this case all accessories which are necessary for operation, such as oil or gas firing

equipment, combustion air fan, oil preheater, control panel or switchboard and feeding device, can

be mounted on the skid, toosed to

Page 2: Packman Group Packman Group 83 Vertical steam boiler

www packmangroup com. .Packman G r o u p General Catalog Packman G r o u p82 83

Ste

am b

oile

r ro

om

Vertical steam boiler

Packman vertical steam boiler PSB series are designed with simple mechanical

structure via modern machinery and equipment to to conform to the latest

regulations of EN and DIN standards.

The PSB series are user friendly, and use the latest technology to meet every

customers needs.

More info about this product.Scan this code to receive a 3D product file.

Scan this code To access the Pakman product selection application and select this product.

Ste

am b

oile

r ro

om

Boiler

exp

Product Capacity Calculation & Selection:

The Steam boiler selected based on maximum require capacity and type of process

The better way to select the capacity and pressure of the boiler is following below

steps:

1- Calculate the maximum heat load based on your process.

2- Adding 20% to maximum load for coefficient of confidence.

3- Consider the 80% average efficiency for vertical steam boiler.

4- Calculate pressure based on your project and distance between boiler and

consumer.

5- Determined the number of boiler you have: it is better you choose number of boiler

for 100% of full load

Finally you can select the model from the table in bellow.

The vertical steam boiler is robust and economical. The furnace is formed by the fire tube. The flue

gases are directed through topped smoke tubes .

Constructional design boiler is especially suitable for the combustion of liquid or gaseous fuels. It

can, however, as well be used for solid fuels. Coal or wood performances.

Fire tube:

The chosen diameter makes sure that an unobjectionable flame can develop and a complete

burnout is guaranteed. The decision whether plane or spiral fire tubes are to be used depends on

the diameter and the working pressure. The arrangement in the inferior part of the water space has

an especially favorable effect on the heat exchange and the water circulation, and allows a clear

arrangement of the remaining flue gas passes. Boiler supports, skids: The boiler body is based on

supports. Most of the unit are delivered on skids; by that special foundations for the installation are

not required. In this case all accessories which are necessary for operation, such as oil or gas firing

equipment, combustion air fan, oil preheater, control panel or switchboard and feeding device, can

be mounted on the skid, toosed to

Page 3: Packman Group Packman Group 83 Vertical steam boiler

www packmangroup com. .Packman G r o u p General Catalog Packman G r o u p84 85

Ste

am b

oile

r ro

om

TECHNICAL DATA100 150 200 300 400 500(CAPACITY (KW

Heating Surface (Sq. m)

Steam Volume (Cu. m)

(Steam Output (Kg/h @ 100 °C

Output (kcal/h) [x1000000]

Pressure drop in boiler

(mbar)

Firing Rate Gas (m3/h)

Firing Rate fuel oil (lit/h)

Firing Rate Heavy fuel oil (lit/h)

Overall

Stack to Ground

Burner to Ground

Boiler O.D.

Boiler Head to LCB

Overall

Steam Outlet (@10 bar)

Feed Water Inlet

Safety Valve

Drain

Stack I.D.

Side Clearance

Boiler Room Length (Min.)

Shipping Weight (@10 bar)

37.2

0.065

156

0.086

3.92

10

9.31

8.78

2030

1660

815

800

890

950

930

1”

1”

2 x ¾"

1”

6"

500

660

--

--

--

--

--

--

--

A

B

C

D

E

F

G

N1

I

N3

N4

S

--

--

--

--

BOILER WEIGHT

MINIMUM BOILER ROOM CLEARANCES

CONNECTIONS

WIDTHS

HEIGHTS

APPROXIMATE FUEL CONSUMPTION AT RATED CAPACITY BASED ON NOMINAL 82% EFFICINCY

46.2

0.73

234

0.129

5.88

15

13.97

13.17

2030

1660

815

880

970

1035

930

1”

1”

2 x ¾"

1”

6"

500

760

55.7

1.24

312

0.179

4.12

20

18.63

17.56

2030

1660

815

950

1030

1100

930

1"

1"

2 x ¾"

1"

6"

500

860

63.3

1.4

468

0.258

6.05

30

27.93

26.34

2365

1960

970

1060

1150

1210

930

1"

1"

2 x ¾"

1"

8”

500

1260

74.3

1.61

625

0.344

4.17

40

37.24

35.12

2365

1960

970

1170

1260

1320

930

1"

1"

1"

1"

8”

500

1480

89.2

1.78

780

0.43

6.7

50

46.55

43.9

2365

1960

970

1270

1360

1420

930

1"

1"

1"

1"

8”

500

1680

The measures and weights might be different from final product by less than 10%

Vertical Clean Steam Boilers

Vertical clean steam boilers are used to produce pure and clean steam, free of any harmful substances and impurities. Applications for pure and clean steam are found in the food, cosmetic, biochemical, and pharmaceutical industries, as wellas for sterilization and any direct steam heating processes where the demands onsteam quality are very high.Our clean steam boilers has been designed to provide sterilizer grade clean steam from suitably treated water using oil or gas burners as the heating medium and can besuppliedwith orwithout an integral feedwater pre-heating.Our clean steam boiler coverssteam outputs from 100 kWup to700 kW and other capacity units can be designed to order. The boiler ismanufactured from AISI 304L stainless steel and all internal surfaces are passivatedtoprovide a corrosion resistancesurface and developed withhighefficiencies, in rigid and reliabledesigns,ensuring low operation and maintenance cost.Skilled engineers provide technical support, already from the first contact withinthe sales department, ensuring the best individual guidance in choosing the correct product for the actual application. From initial assessment of customers clean steam needs, through design, manufacturing, documentation and validation, delivery and deployment, to maintenance and life cycle support,weensure all elements fit perfectly to achieve the highest systemperformance.Benefits:1.Short delivery times for standard PureSteam Generators2.High energy efficiency by ideal design and energy retrieval measures3.Vertical design withminimal areademand4. All clean steam and feed water wetted parts in AISI 304Lstainless steel5. Using PLC controlled to regulate generator clean steam outlet pressure, generator water levelQUALITY CONTROL:1.Strength calculation report withapplied materials information.2. 100% NDT (non-destructive inspection) report of steel plate tube and welding rod including RTand UTexamination reports.3.Hydraulic test report:ensure the standardworkingpressure and safety.

Ste

am b

oile

r ro

om

More info about this product.