p2050b025, 1/2”, pressure independent valve nema 2, ip42, ul enclosure type 2 agency listings†...

5
Technical Data 1630 Service chilled, hot water, up to 60% glycol Flow Characteristic equal percentage Size [mm] 0.5” [15] End Fitting NPT female ends Body forged brass, nickel plated Ball chrome plated brass Stem nickel plated brass Seat Teflon® PTFE Seat O-ring EPDM (lubricated) Characterized Disc Brass Packing EPDM Diaphragm Polyester reinforced Silicone Regulator Components stainless steel / brass / Nitrile Body Pressure Rating [psi] 600 Media Temperature Range (Water) 0°F to 212°F [-18°C to 100°C] Differential Pressure Range 5 to 50 psi Close-Off Pressure 200 psi Rangeability 100:1 Valve Accuracy ± 5%* Weight 2 lb [0.9 kg] GPM 2.5 GPM Range 0...(1.6-3.0) Leakage ANSI Class IV (0.01% of rated valve capacity at 50 psi differential) *See page 3 of the PICCV technical documentation for details. Application The Pressure Independent Characterized Control Valve is typically used in air handling units on heating and cooling coils, and fan coil unit heating or cooling coils. Some other common applications include unit ventilators and VAV reheat coils. This valve is suitable for use in a hydronic system with constant or variable flow. This valve is designed with MFT functionality which facilitates the use of various control input. Suitable Actuators Non-Spring Spring P2050B025 LR, LRC, KR TFR, LF Dimensions (Inches [mm]) 2.47” [62.8] 1.35” [34.2] 6.30” [160] C A B D E F KRB24-3 A B C D E F 6.56” [167] 4.47” [114] 5.09” [129] 2.34” [59.4] 1.33” [34] 1.25” [32] P2050B025, 1/2”, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA / CARIBBEAN Date created, 12/04/2017 - Subject to change. © Belimo Aircontrols (USA), Inc.

Upload: others

Post on 17-May-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: P2050B025, 1/2”, Pressure Independent Valve NEMA 2, IP42, UL Enclosure Type 2 Agency Listings† cULus acc. to UL60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EC Noise

Technical Data 1630

Service chilled, hot water, up to 60% glycolFlow Characteristic equal percentageSize [mm] 0.5” [15]End Fitting NPT female endsBody forged brass, nickel platedBall chrome plated brassStem nickel plated brassSeat Teflon® PTFESeat O-ring EPDM (lubricated)Characterized Disc BrassPacking EPDMDiaphragm Polyester reinforced SiliconeRegulator Components stainless steel / brass / NitrileBody Pressure Rating [psi] 600Media Temperature Range (Water)

0°F to 212°F [-18°C to 100°C]

Differential Pressure Range 5 to 50 psiClose-Off Pressure 200 psiRangeability 100:1Valve Accuracy ± 5%*Weight 2 lb [0.9 kg]GPM 2.5GPM Range 0...(1.6-3.0)Leakage ANSI Class IV (0.01% of rated valve capacity at

50 psi differential)*See page 3 of the PICCV technical documentation for details.

ApplicationThe Pressure Independent Characterized Control Valve is typically used in air handling units on heating and cooling coils, and fan coil unit heating or cooling coils. Some other common applications include unit ventilators and VAV reheat coils. This valve is suitable for use in a hydronic system with constant or variable flow. This valve is designed with MFT functionality which facilitates the use of various control input.

Suitable Actuators Non-Spring SpringP2050B025 LR, LRC, KR TFR, LF

Dimensions (Inches [mm])

2.47” [62.8]

1.35

” [3

4.2]

6.30” [160]

C

A

B

D

E F

KRB24-3

A B C D E F6.56” [167] 4.47” [114] 5.09” [129] 2.34” [59.4] 1.33” [34] 1.25” [32]

P2050B025, 1/2”, Pressure Independent ValveChrome Plated Brass Ball and Brass Stem, NPT Female Ends

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA / CARIBBEAN

Date

cre

ated

, 12/

04/2

017

- Sub

ject

to c

hang

e. ©

Bel

imo

Airc

ontro

ls (U

SA),

Inc.

Page 2: P2050B025, 1/2”, Pressure Independent Valve NEMA 2, IP42, UL Enclosure Type 2 Agency Listings† cULus acc. to UL60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EC Noise

Dimensions (Inches [mm])

C

AB

D

E F

2.6"[66]

6.5" [165]

1.69"[42]

3.22"[82]

2.34"[59.4]

LRB24-SA

A B C D E F7.68” [195] 4.47” [114] 7.13” [181] 2.34” [59.4] 1.48” [38]

Dimensions (Inches [mm])

C

A

B

D

7.64"[194]

4.49"[114]

2.28"[58]

3.78"[96]

E F

LF24-MFT

A B C D E F8.1” [206] 4.47” [114] 8.54” [217] 2.34” [59.4] 1.89” [48]

Dimensions (Inches [mm])

C

A

B

D

E F

7.5" [191]

1.69"[42]

3.22"[82]

2.34"[59.4]

2.6"[66]

LRX24-MFT

A B C D E F8.68” [220] 4.47” [114] 7.13” [181] 2.34” [59.4] 1.48” [38]

Dimensions (Inches [mm])

6.28"[159.55]

3.0"[76.2]

2.93"[74.5]

2.40"[61]

C

A

B

D

E F

TFRX24-MFT

A B C D E F7.1” [180] 4.47” [114] 6.98” [177] 2.34” [59.4] 1.5” [38]

P2050B025, 1/2”, Pressure Independent ValveChrome Plated Brass Ball and Brass Stem, NPT Female Ends

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA / CARIBBEAN

Date

cre

ated

, 12/

04/2

017

- Sub

ject

to c

hang

e. ©

Bel

imo

Airc

ontro

ls (U

SA),

Inc.

Page 3: P2050B025, 1/2”, Pressure Independent Valve NEMA 2, IP42, UL Enclosure Type 2 Agency Listings† cULus acc. to UL60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EC Noise

Dimensions (Inches [mm])

C

A

B

D

E F

2.6"[66]

6.5" [165]

1.69"[42]

0.78" [20]

3.22"[82]

2.34"[59.4]

FlowSetR™ Dimensions

LRB24-3, LRX24-3, LRCB24-3

A B C D E F7.68” [195] 4.47” [114] 7.91” [201] 2.34” [59.4] 1.48” [38]

P2050B025, 1/2”, Pressure Independent ValveChrome Plated Brass Ball and Brass Stem, NPT Female Ends

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA / CARIBBEAN

Date

cre

ated

, 12/

04/2

017

- Sub

ject

to c

hang

e. ©

Bel

imo

Airc

ontro

ls (U

SA),

Inc.

Page 4: P2050B025, 1/2”, Pressure Independent Valve NEMA 2, IP42, UL Enclosure Type 2 Agency Listings† cULus acc. to UL60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EC Noise

Technical Data 2258

Power Supply 24 VAC, ±20%, 50/60 Hz, 24 VDC, ±10%Power Consumption Running 1.5 WPower Consumption Holding 0.2 WTransformer Sizing 2 VA (class 2 power source)Electrical Connection 18 GA plenum rated cable with 1/2” conduit

connector protected NEMA 2 (IP54) 3ft [1m] 10ft [3m] and 16ft [5m]

Overload Protection electronic thoughout 0° to 90° rotationInput Impedance 600 ΩAngle of Rotation 90°Direction of Rotation (Motor) reversible with built-in switchPosition Indication integrated into handleManual Override external push buttonRunning Time (Motor) 90 secAmbient Temperature Range -22°F to 122°F [-30°C to 50°C]Storage Temperature Range -40°F to 176°F [-40°C to 80°C]Housing NEMA 2, IP42, UL Enclosure Type 2Agency Listings† cULus acc. to UL60730-1A/-2-14, CAN/CSA

E60730-1:02, CE acc. to 2004/108/ECNoise Level (Motor) <35 dB (A) Servicing maintenance freeQuality Standard ISO 9001

†Rated Impulse Voltage 800V, Type action 1.B , Control Pollution Degree 3.

LRX24-3On/Off, Floating Point, Non-Spring Return, 24 V

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA / CARIBBEAN

Date

cre

ated

, 11/

29/2

017

- Sub

ject

to c

hang

e. ©

Bel

imo

Airc

ontro

ls (U

SA),

Inc.

Page 5: P2050B025, 1/2”, Pressure Independent Valve NEMA 2, IP42, UL Enclosure Type 2 Agency Listings† cULus acc. to UL60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EC Noise

Wiring Diagrams

INSTALLATION NOTES

Provide overload protection and disconnect as required.

Actuators may be connected in parallel. Power consumption and input impedance must be observed.

Actuators may also be powered by 24 VDC.

Actuators Hot wire must be connected to the control board common. Only connect common to neg. (-) leg of control circuits. Terminal models (-T) have no-feedback.

Actuators with plenum cable do not have numbers; use color codes instead.

Meets cULus requirements without the need of an electrical ground connection.

! WARNING! LIVE ELECTRICAL COMPONENTS!During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury.

2 3 1824 VAC Transformer

Blk (1) Common

Red (2) + Hot

Wht (3) Y Input

LineVolts

1

On/Off

2 3 1824 VAC Transformer

Blk (1) Common

Red (2) + Hot

Wht (3) Y Input

LineVolts

1

Floating Point

ComHot2 3 18

Blk (1) Common

Red (2) + Hot

Wht (3) Y Input

LineVolts

24 VAC Transformer

1

Floating Point - Triac Source

2 18Blk (1) Common

Red (2) + Hot

Wht (3) Y Input

LineVolts

24 VAC Transformer

ComHot6 1

Floating Point - Triac Sink

LRX24-3On/Off, Floating Point, Non-Spring Return, 24 V

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA / CARIBBEAN

Date

cre

ated

, 11/

29/2

017

- Sub

ject

to c

hang

e. ©

Bel

imo

Airc

ontro

ls (U

SA),

Inc.