SITE BOU
NDARY
EXISTING ANNEXE THEATRE BUILDING
EXISTINGEDUCATION BUILDING
EXTENT OF
EXTERNAL WORKS
EXTENT OF
EXTERNAL WORKS
EXISTING ROAD
EXISTING ROAD
EXISTING
BRICK PAVED TRAM LIN
EEXTENT OF EXTERNAL WORKS
EXTENT OF EXTERNAL WORKS
EXISTING TREES
TO BE REMOVED
EXISTING TREES
TO BE REMOVED
EXTENT OF EXTERNAL WOR
KS
EXISTING GAS ENCLOSURE
TO BE DEMOLISHED AND
RELOCATED
EXISTING OUTDOOR KILN WALLS,
STEEL POSTS AND METAL ROOF
OVER TO BE DEMOLISHED
EXISTING SUBSTATION
TO BE REMOVED
PROPOSED BIKE RACKS
PROPOSED BIKE RACKS
PROPOSED
BIKE RACKS
NEW TREE
NEW TREE
NEW TREE
NEW TREENEW TREE
NEW TREE NEW TREE
NEW TREE
EXISTING CHIMNEY
AND CONCRETE
BASE TO REMAIN
NEW TERRACED
INDIGENOUS GARDEN
FFL 2.900
FFL 2.850
FFL 2.400
FFL 2.400
NEW GAS METER
ENCLOSURE TBC
THE DISTANCE BETWEEN THESE M
ARKS SHOULD
MEASURE
AS 1
00
mm
WHEN SHEET IS
PRINTED TO SCALE
AS IN
DICATED
Project No.
Date
Drwn
Co-Ord
Chck
Drawing Status
RevisionDrawing No.
CONTRACTORS SHALL VERIFY JOB DIMENSIONS BEFORE ANY JOB COMMENCES. ALL SHOP
DRAWINGS SHALL BE SUBMITTED TO THE SUPERINTENDENT AND MANUFACTURE SHALL NOT
COMMENCE PRIOR TO THE RETURN OF UNAMENDED SHOP DRAWINGS SIGNED BY THE
CONSULTANT. FIGURED DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED. THIS DRAWING
SHOULD BE READ IN CONJUNCTION WITH ALL RELEVANT CONTRACT, SPECIFICATIONS AND
DRAWINGS. COPYRIGHT OF THIS DRAWING IS VESTED IN JOHN WARDLE ARCHITECTS.
IT IS THE POLICY OF JOHN WARDLE ARCHITECTS TO PROVIDE INFORMATION IN HARD COPY
FORMAT. IF A PARTY REQUESTS (REQUESTING PARTY) JOHN WARDLE ARCHITECTS TO PROVIDE
INFORMATION IN A FORMAT OTHER THAN PORTABLE DOCUMENT FORMAT (PDF) THE REQUESTING
PARTY ACCEPTS AND ACKNOWLEDGES THE TERMS AND CONDITIONS FOR USE OF THE DIGITAL
INFORMATION PROVIDED. REFER TO DIGITAL TRANSFER DISCLAIMER.
THIS DRAWING IS AN UNCONTROLLED COPY UNLESS STAMPED OTHERWISE
+61 3 8662 0400
Level 2, 25 Rokeby Street, Collingwood, Vic 3066 Australia
ABN 83 006 814 268
www.johnwardlearchitects.com
General Notes
PRINTED:
FILE:
Client
Project
Title
Scale @ A1
16/07/2019 11:05:25 AM
C:\_localREVIT\1803_UTAS Inveresk_B03_R
19_M
anuel.canestrini.rvt
1 : 200
E
UTAS INVERESK CAMPUS
UTAS
LIBRARY & STUDENT SERVICES BUILDING
1803
SCHEMATIC DESIGN
NR
MAY 2019 MC
MC
AR 0400EXTERNAL WORKS
EXTERNAL WORKS PLAN
© 2019 John Wardle Architects
Rev. Issue Revision Description Date Appr by
A FOR INFORMATION 07.05.2019
B FOR COSTING 17.05.2019
C DA PACKAGE - PRELIMINARY REVIEW 29.05.2019
D DA PACKAGE - SIGN OFF REVIEW 31.05.2019
E ISSUE FOR COORDINATION 15.07.2019
EX 150 SEWER
EX 375 SWD EX 375 SWD
EX 150 SEWER
EX 225 SEWER
EX 2
25 S
EWER
EX SEWER RISING MAIN
EX SEWER RISING MAIN
EX WATER M
AIN
EX WATER MAINEX WATER MAIN
EX WATER MAIN
EX SEWER RISING MAIN
EX WATER M
AIN
EX WATER M
AIN
EX 225 SEWEREX WATER MAIN
EX 450 SWD
EX 225 SEWER
EX 375 SWD
EX GAS MAIN
EX SEWER RISING MAIN
NEW GAS CONNECTION TOBE CO-ORDINATED INCONJUNCTION WITH SITESERVICES RELOCATIONS
GAS METER ASSEMBLYLOCATION SUBJECT TOCO-ORDINATION
EX GAS MAIN
EX W
ATER
MAI
N
EX WATER MAIN
REFER TO GRNDFLOOR PLAN FOR GASSUPPLY TO BLDG.
Design: GMSDate: JUL 2019 P1
MUOT0111-SK- H00HYD SERVICES
5
3
2
1
A3000
6000
9000
9000
HFEDCB9000 9000 9000 9000 9000 9000 7500
I
4
SITE BOUNDARY
AIRLOCKENTRY
ENTRY AIR
LOCK
G
9000
3000
3000
6000
3.0 m²
SWITCH
ROOM
1:20
FFL 2.900
FFL 2.900
FFL 2.900
FFL 2.900
FFL 2.520
FFL 2.900
RETAIL TENANCY
CLEANER
WASTE/BIN
LIFT
FFL 2.568
STUDENT
EXPERIENCE
NEW PEDESTRIAN LANEWAY
FFL 2.900
DDA WC
RETAIL B.O.H.
FFL 2.900
FFL 2.400
KITCHEN
EXHAUST
FLUE
NEW INGROUND
GREASE TRAP
SECURITY
DOORS
EXTENT OF FACADE
OVER SHOWN DASHED
EXTENT OF FACADE
OVER SHOWN DASHED
EXISTING CHIMNEY AND
BASE TO BE RETAINED
F.I.P.
FW BOOSTERCONTROL VALVE
NEW
RAINWATER
TANK
EXISTING FENCE AND
GATE TO REMAIN
F.H.R.
F.H.R.
RAINWATER PLANT
COLD WATER
ASSEMBLY
HOLD OPEN DOORS
FOLDABLE WALL
EGRESS DOOR
METER PANEL
NEW RETAINING
WALL
EXISTING TREE
TO REMAIN
BOLLARDS
EXISTING STONE BUILDING
STAIR 2
UNISEX
WC
STAIR 1
STAIR 2
TERRACED
INDIGENOUS GARDEN
TO LANDSCAPE ARCHITECT'S DESIGN
EXISTING ANNEXE THEATRE BUILDING
STAIR 1
BIKE RACKS AS REQUIRED
BIKE RACKS AS REQUIRED
COFFEE TO GO /
TOP HINGED
AWNING WINDOW
CONCRETE
SEATING BENCH
EXTENT OF FACADE
OVER SHOWN DASHED
EXTENT OF FACADE
OVER SHOWN DASHED
EXISTING CHIMNEY AND
BASE TO BE RETAINED
NEW
RAINWATER
TANK
EXISTING FENCE AND
GATE TO REMAIN
SPACE ALLOCATION
FOR RELOCATED KILNS
TBC
CONCRETE
SEATING BENCH
METER PANEL
BIKE RACKS AS REQUIRED
NEW RETAINING
WALL
EXISTING TREE
TO REMAIN
DRINKING
FOUNTAIN
1935
3528
37
3374963
LIBRARY
PROCESSINGSTUDENT
KITCHENETTE
CONSULTATION CONSULTATION
CONSULTATION
LOUNGE
SWITCH ROOM
ELEC. & COMMS
MECH. RISER
STORE
THE DISTANCE BETWEEN THESE MARKS SHOULD MEASURE
AS 1
00
mmWHEN SHEET IS PRINTED TO SCALE AS INDICATED
Project No.
Date
Drwn
Co-Ord
Chck
Drawing Status
RevisionDrawing No.
CONTRACTORS SHALL VERIFY JOB DIMENSIONS BEFORE ANY JOB COMMENCES. ALL SHOP
DRAWINGS SHALL BE SUBMITTED TO THE SUPERINTENDENT AND MANUFACTURE SHALL NOT
COMMENCE PRIOR TO THE RETURN OF UNAMENDED SHOP DRAWINGS SIGNED BY THE
CONSULTANT. FIGURED DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED. THIS DRAWING
SHOULD BE READ IN CONJUNCTION WITH ALL RELEVANT CONTRACT, SPECIFICATIONS AND
DRAWINGS. COPYRIGHT OF THIS DRAWING IS VESTED IN JOHN WARDLE ARCHITECTS.
IT IS THE POLICY OF JOHN WARDLE ARCHITECTS TO PROVIDE INFORMATION IN HARD COPY
FORMAT. IF A PARTY REQUESTS (REQUESTING PARTY) JOHN WARDLE ARCHITECTS TO PROVIDE
INFORMATION IN A FORMAT OTHER THAN PORTABLE DOCUMENT FORMAT (PDF) THE REQUESTING
PARTY ACCEPTS AND ACKNOWLEDGES THE TERMS AND CONDITIONS FOR USE OF THE DIGITAL
INFORMATION PROVIDED. REFER TO DIGITAL TRANSFER DISCLAIMER.
THIS DRAWING IS AN UNCONTROLLED COPY UNLESS STAMPED OTHERWISE
+61 3 8662 0400
Level 2, 25 Rokeby Street, Collingwood, Vic 3066 Australia
ABN 83 006 814 268
www.johnwardlearchitects.com
General Notes
PRINTED:
FILE:
Client
Project
Title
Scale @ A1
16/07/2019 10:53:36 AM
C:\_localREVIT\1803_UTAS Inveresk_B03_R19_Manuel.canestrini.rvt
1 : 100
G
UTAS INVERESK CAMPUS
UTAS
LIBRARY & STUDENT SERVICES BUILDING
1803
SCHEMATIC DESIGN
MC/NR
MAY 2019 Designer
MC
AR 1000GENERAL ARRANGEMENT PLAN
LEVEL 01 (GROUND)
© 2019 John Wardle Architects
Rev. Issue Revision Description Date Appr by
A FOR INFORMATION 07.05.2019
B FOR INFORMATION 10.05.2019
C FOR COSTING 17.05.2019
D DA PACKAGE - PRELIMINARY REVIEW 29.05.2019
E DA PACKAGE - PRELIMINARY REVIEW 30.05.2019
F DA PACKAGE - SIGN OFF REVIEW 31.05.2019
G ISSUE FOR COORDINATION 15.07.2019
EX 150 SEWER
EX 375 SWD EX 375 SWD
EX 150 SEWER
EX 225 SEWER
EX 2
25 S
EWER
EX SEWER RISING MAIN
EX SEWER RISING MAIN
EX WATER M
AIN
EX WATER MAINEX WATER MAIN
EX WATER MAIN
EX SEWER RISING MAIN
EX WATER M
AIN
EX WATER M
AIN
EX 225 SEWER
EX WATER MAIN
EX 450 SWD
EX 225 SEWER
EX 375 SWD
EX GAS MAIN
EX SEWER RISING MAIN
DPDP t/b
DP t/b DP t/bDP t/bDP t/bDP t/b
DP t/b
DP t/b
DP t/b
DP t/bDP t/b
DP t/b
DP t/b
DP t/b
ABOVE GND FIRST FLUSHAND CONNECTION TO TANK
50KL ABOVE GNDRAIN WATER TANK6.0 X 3.0 X 3.5 HIGHON A STAND
TANK OVERFLOWTO SWD
DP t/b
NEW SWD NEW SWD
NEW
SW
D
NEW SWD
NEW SEWER
NEW
SW
D CW, TRW ANDHW RISERS
CW, TRWAND HWRISERS
VALVES TOTOILETS
SEWERSTACK
SEWER STACKAND OFFSET
CONNECT TO EXSEWER BRANCHFOR BUILDING
100 GREASE AND SEWERDRAIN BR'S FOR TENANCY
GREASEARRESTOR
WATER METER ANDFIRE SERVICE VALVEASSEMBLY ANDRETAIL TO BECO-ORDINATED
CW FOR RETAIL
GAS RISER
GAS VALVE FOR TENANCY
DP t/b
REFER TO SITE PLANFOR GAS SUPPLYFROM METERS
Design: GMSDate: JUL 2019 P1
MUOT0111-SK- H01HYD SERVICES