p.3 THE STANDARDS Standards bodies Copper: correspondence between categories and classes Copper: the different types of shielding Opticalfibre:multi-modeandsingle-mode Whichproductsforwhichapplications?
p.6 DESIGN Generalstructureofaprecablingsystem Generalarrangement
p.10 INSTALLATION Storage of date cables Handling of data cables Handlingofopticalfibrecables
p.15 TEST PARAMETERS AND INTERPRETATION OF ERRORS Visualinspection Copper: Interpretation of errors Fibre:Testingandmeasurement
p.19 GLOSSARY
CONTENTS
2
3
THE STANDARDSThecablingsystemstandardshavebeencreatedtodefineauniform,standardqualitythroughouttheworld,regardlessoftheproductsused.It isthereforeessential toknowthemeaningandthecorrespondenceofthesestandardswithrespecttotheproductsused(cablesandconnectors)andtheapplicationstobesupported.
StandardS bodieS
Therearethreestandardsorganisations:theNorthAmericanEIA/TIAstandardthatworksincategories(Cat5e,Cat6,Cat6A,etc.),ISO,theinternationalstandardandtheEuropeanENstandardthatdefinesClasses(D,E,Ea.etc.)
Copper: CorreSpondenCe between CategorieS and ClaSSeS
EIA/TIAdefinescomponentsandthecommunicationlinkaccordingtoCategories.
Max. FrequenCy 100Mhz 250Mhz 500Mhz 600Mhz 1000Mhz
Components / link Cat. 5e Cat. 6 Cat. 6a
eia/tia 568-C.2 568-C.2 568-C.2
ISO and EN standards, for their part define the components according to category and the communication chain according toClass.Max. FrequenCy 100Mhz 250Mhz 500Mhz 600Mhz 1000Mhz
Components Cat. 5e Cat. 6 Cat. 6a Cat. 7 Cat. 7a
link Class d Class e Class ea Class F Class Fa
iSo/ieC 11801 ed2.0 11801 ed2.0 aMd 1.0 / aMd 2.0 1181 11801 ed2.0 aMd 1.0 / aMd 2.0 1181
en 50173-1 50173-1 50173-1 50173-1 50173-1
Copper: tHe diFFerent typeS oF SHieldingTheshieldingofcablesandconnectorsprotectsthemagainstelectromagneticinterference(e.g.frompowercircuits).
Theshieldingofacableisdefinedby3letters,«U»forunshielded,«F»foraluminiumfoilshieldingand«S»foraluminiumbraid.Thepositionofthisshielding,eitheraroundtheoutsideofthewholecableoraroundeachofthetwistedpairsisspecifiedbythefollowingsymbol:
Thus,anF/UTPcableisonewithanoverallaluminiumfoilshieldingonly.
TherearethreeversionsofRJ45connector:unshielded(orUTP),9-pinshieldedwithearth(orFTP)and360-degreeEMCshielded(orSTP)
optiCal Fibre: Multi-Mode and Single-ModeISO11801Edition2classesopticalfibreinto4mainfamilies:OM1,OM2andOM3formultimodeandOS1forsingle-mode.
type oF etHernet network
type oF Fibre 100Fx 1000Sx 1000lx 10gS 10gl 10glx4
network bit rate 100Mbits gigabit 10 gigabit
Multi-Mode oM1 62.5/125µM 2km 275m 550m 33m n/a 300m
Multi-Mode oM2 50/125µM 2km 550m 550m 82m n/a 300m
Multi-Mode oM3 50/125µM 2km 550m 550m 300m n/a 300m
Single-Mode oS1 9/125µM n/a n/a 5km n/a 10km 10km
* twisted pair
4
u/utp*Overallshielding Individualshielding
of twisted pairs
wHiCH produCtS For wHiCH appliCationS?Adifferenttypeofcableandopticalfibrewillbeusedaccordingtotheapplicationsandperipheralstobeused.
Copper ConneCtivity Fibre ConneCtivity
appliCationS Cat 5e Cat. 6 Cat.6 10g Cat. 6a oM1 oM2 oM3 oS1
10/100MbitS network
gigabitS network
10gigabitS network
40gigabitS network
100gigabitS network
analogue telepHony
ip pHone : voip
voip + poe
xdSl
CCtv (witH balunS)
poe SySteM (ex: CaMera)
poep SySteM
tnt televiSion
ip televiSion
ip alarM SySteM
*
5
: perfectly adapted : adapted : little adapted * With 900MHz cable
DESIGN
Pre-cabling a building or a campus consists in providing a network of cables and associated connectors to enable the occupants tointerconnectanytypeofdata-processingortelecommunicationequipment.
Thecablingsystemmustthereforebe:
•Systematic: Socketsmustbeprovidedineachofficeorroom.•Reconfigurable:Rapidreconfigurationmustbefeasible,withoutstructurallyalteringthecabling.•Standardised: Theconnectionconventionsusedmustbeidenticalatallpointsthroughoutthebuilding.•Universal: Thetransmissionperformanceofitscomponents(cables,connectors,etc.)mustbeatleastequaltothose Specifiedinthestandard.
general StruCture oF a preCabling SySteM
Thebuildings’cablingisorganisedinahierarchical«star»topology.Itcomprisesamainequipmentroomandseveralsecondaryequipmentroomslinkedtogetherby«backbones».
Thearchitecturebreaksdownintotwosetsofcables:
«Verticalcabling»or«primarycabling»calledCampusbackboneandBuildingbackbone,representinginter-buildinglinks.
«Horizontalcabling»coveringtheconnectionsbetweentheterminaloutletsandthetelecommunicationscloset.Thisisthestandarddistributionwiringoverafloorofabuilding.
6
general arrangeMent
n From the Campus distributor to the terminal outlet:
TheCampus andBuilding distributors are connected by a backbone, limited to a length of 100m for twisted pair cables and severalkilometresforopticalfibre.ThelinksbetweentheBuildingdistributorandtheFloordistributorcanalsobeformedusingopticalfibretomeetdatatransmissionsecurityrequirements.
Terminals
RJ45 Connector
SR/LTE : Floor distributor in the Telecommunications closet
RG/LTI : Building distributor in the Building Equipment Room
RC/LTC : Campus distributor in the Campus Equipment Room
Campus Backbone Building Backbone Horizontal Cabling
Global Precabling
7
Horizontal Cabling
Building Backbone
Campus Backbone
RC/LTC : Campus distributor in the Campus Equipment Room
RG/LTI : Building distributor in the Building Equipment Room
SR/LTE : Floor distributor in the Telecommunications closet
Workstation access point
n distribution to several multi-storey buildings
8
ThelinksbetweentheCampusdistributorandtheBuildingdistributorandFloordistributorsmaybemaderedundanttoensurecontinuityofserviceintheeventofalossofconnectionononeofthenodes.
Patch rack
Channel link
Permanent link
CP : Consolidation Point
n Consolidation point
Theconsolidationpoint isan intermediateconnectionthatprovidesflexibility inopenofficespaceswithouttheneedtomodifytheentirecablinginfrastructure.ItconsistsofafemaleRJ45socketandoneendandanRJ45Maleconnectorattheother.
CHANNELLINK=PERMANENTLINK+CORDS=100mmaximumPERMANENTLINK=90mmaximumCORDS=10mmaximum(totalforthetwocords).
9
Switch
Patch Panel
MAX
BOÎTE DE CÂBLE
BOÎTE DE CÂBLE
BOÎTE DE CÂBLE
10
Storethecableinawarm,dryplaceawayfromfrost
Donotpushonthecableto roll the reel
Avoidimpactwhenrollingthe reels
Set the reels down on thegroundorapallet
Reelsmustnotbestackedmorethantwohigh
Similarlyboxesmustnotbestackedmorethanthreehigh
INSTALLATION
Storage oF network CableS
Thenetworkcablesaregenerallystoredonwooden,plyorplasticcablereelsandreel-outboxes,inordertoavoidmechanicalstresses.
Afewbasicrulesmustbeobserved:
Handling oF network CableS
n unwinding the cable
Whenlayingthecable,thephysicalstressesonthecablemustbeminimizedasmuchaspossible.Reelstandsarefrequentlyusedtomountthereelaboutahorizontalaxisofrotation.Alternatively,afloor-mountedreelrollersystemcanbeused,consistingoftwocylindricalbarsmountedonrollerbearings(rollers).Thereelisrotatedsimplybygentlypullingonthecable.
1m
11
Thecablemustbeunwoundfromthetop,withaslightpullingforce.Theendofthecablethathasbeengripped,andthathasthereforesufferedmechanicaldamage(tension,pinching),mustbecutoveralengthofapproximately0.5to1metre,oncethedesiredlengthhasbeenobtained.
Reelstandsystem Floor-mountedcablereelrollersystem
ITISFORBIDDENtounwindthecablefromareelthatislayingflat,asthiscausesseveretwistingofthecable
n laying the cable
Certainrulesarecommonlyappliedandmustbetakenintoaccountatthecablingsystemdesignphase,inparticularwithagoodknowledgeofthetopologyofthesiteandthedifferentpossibleroutes:
12
90°
courants faibles
courants forts
min 0.3 m
courants faibles courants forts
Powerandlow-voltagecablestobekeptmin.30cmapart
Similarly,donotwalkoncables.
Cablecrossoversshouldpreferablybeat90°
Notoverloadthecabletray
n installing network cables
Asageneralrule,maximumcareshouldbetakentoavoidstressesonthecablethatmightimpairitsintegrity.
13
Do not twist the cable Avoidplasticcableties Useflexible«Velcro»typeself-grippingties
Complywiththespecifiedbending radii
Avoidsharpanglessuchasloopsin the wire ways
Handle cables with care duringpulling
Handling oF optiCal Fibre CableS
n Horizontally laid internal cables
Internalopticalfibrecablesarenotgenerallyprovidedwithacentralstrengthmemberforpulling.Iftheycannotbesimplylaid,strengtheningelementsmustbeusedtopullthecable,suchas:- Aramidfibre(Yellow)- Glassfibre.
Theopticalcabletechnicaldatasheetsspecifythetensileforcethatcanbewithstoodbyeachcable(expressedinNewtons:100Newtonsareapproximatelyequivalentto10kg).Thecableshouldnotbepulledbyitsoutersheath,asthiswillcauseittostretch,transferringthemechanicalstressestothefibresthemselves.
n vertically laid internal cables
Therulesareidenticaltothoseexplainedabove.Whenlayingverticalcables,itisrecommendedtocoilallloose-structurecables2turnsatallfloorlevelstoavoidthefibresdroppingwithinthecable.Thiswillalsopreventverticaltensileforcesinthecableduetotheweightofthefibres.
n external cables
Externalcablesoftenhavethedisadvantageofbeinginstalledoververylongdistances.Allexternalcablesareprovidedwithacentralstrengthmemberforpullingthecableduringinstallation.
Becauseoftheir(flammable)PEsheath,itisstrictlyforbiddentoinstallorlayexternalcablesinsideabuilding.Forreasonsofspread-of-fire,theirpenetrationintoabuildingislimitedtomax.15metresbeforefanning-out.
14
TEST PARAMETERS AND INTERPRETATION OF ERRORSOncethecablingsystemhasbeenlaid,certificationissystematicallyrequested,confirmingitslevelofperformance.Thisconfirmsthequalityofthework,fromthechoiceorcomponentstolayingandformingtheconnections.Acabletesteristhusneededtotestandvalidateeachlink.
viSual inSpeCtionTheinitialinspectionconsistsofavisualcheckoftheinstallation.Attentionmustbepaidtothebasicrulesofaninstallation,namely:- Tighteningofcables- Foldedcablesattheendofwirewaysand/orracks,- Unsheathingandsplittingofpairsatconnections.
Copper: teSting oF perManent link and CHannel linkS
CHANNEL : 100 M
Panneaudebrasssage
PrisemuralePoint de Consolidation (option)
Thisinvolvestestingacompletelink,includingtheRJ45cords.
Thisinvolvestestingalinkfromthepatchpaneltothewall socket.
15
PERMANENT LINk : 90 M
Panneaudebrasssage
PrisemuralePoint de Consolidation (option)
Continuity teSt: Checking of pairs connected according to the colour code
probable CauSeS oF Failure
open CirCuit Cut or broken cable, or wires broken by mechanical force in the connector
damaged rJ45 connector
wires incorrectly inserted in the self-stripping contact
Cable for specific application (e.g. 2 Pairs)
SHort-CirCuit Conducting material between the pin and the wire (e.g.: the wire is touching the shielded cover)
damaged rJ45 connector
Short-circuit in the cable (crushing)
Specific application (e.g. PABX with shunting)
CroSSed pairS Connection convention problem (Mixing of a and b)
Crossed patch cord used
wires connected to the wrong contact
Split pairS wires connected to the wrong contact
lengtH: tested over 90m in permanent link and 100m in Channel link
probable CauSeS oF Failure
additional-lengtH Cable is too long
the nvp is incorrect
lengtH too SHort Cable is cut
one or More pairS too SHort
damaged cable
poor connection
16
Copper: interpretation oF errorS
MeASuReMentS: Checking the different standard parameters
deFinition probable CauSeS oF Failure
delay-Skew difference in delay. Max. difference between the propagation delay time of each of the pairs receiving a same signal transmitted over several pairs
Cable is too long
Cable using different types of insulation according to the pairs
inSertion loSS weakening of the signal according to frequency and in proportion to the length of the link
Cable is too long
the temperature exceeds 20°C
problem of resistance at the termination contacts
next & pSnext next: near-end Cross talk between pairs (application of a test signal to one of the pairs and reception of the induced signal at the same end on the other pair) pSnext: power Sum near-end Cross talk (application of a test signal to 3 pairs and reception of the induced signal on the 4th pair)
problem of split pairs at the connector, poor connection
incorrect measuring head / poor quality patch cords / bad cable
Compression linked to the clamping of the cables, the bending radius or failure to comply with cable geometry requirements
external sources of interference
problem of compatibility between the plug and the connector
return loSS Measurement of the reflected power of the signal echoes due to impedance mismatch along the link
Patch cord impedance problem (100Ω ?)
excessive handling of patch cords that has altered the impedance
Cable handling problem, Failure to comply with cable geometry requirements
poor connection
excessive coiled length before the connector
non-uniform cable impedance - Mixture of 120Ω and 100Ω cables
problem of compatibility between the plug and the connector
defective test adaptor
insulation crushed in the socket
17
Fibre: teSting and MeaSureMent
Allopticaltestssimplyconsistinmeasuringtheoverallopticallossorthatateachcomponentofthelink.Itdoesnotinvolvemeasuringthebandwidth.
n Field tester
Alltestersnowhaveoptionalmulti-modeorsingle-modeopticalheadstovalidateanopticallink.ThesetestersmeasureLinkBudget,allowingittobevalidatedagainstadesiredreferencestandard.Somealsochecktheoperationofthemainnetworks(Ethernet,ATM,etc.)overthelink.
Wheretherearenoproblemsonthelink,theymeasure:- metricdBlosses- thelengthsofthelinkstested,validatingtheLinkBudget.
n Reflectometer (otdR)
Thereflectometerperformsmoredetailedmeasurementsoftheoptical linkand,inparticular,showsthedistanceandthelossesofeveryeventonthelink(Connector,splice,etc.).Eachincidentoreachconnectorcanbeindividuallychecked.Intheeventofaproblemonalink,thisistheonlymeansofidentifyingthefaultencountered.
18
19
GLOSSARYCatv:(CommunityAntennaTeleVision)transmissionofTVsignalbycable
CCtv:(ClosedCircuitTelevision)analoguevideo-surveillancesystem.
Channel:TwistedpairlinkthatincludesthePermanentLinkaswellastheconnectingcordsateachend(e.g.fromthecomputerswitchtotheuser’sPC)
wiring convention type a et b:2methodsofwiringRJ45motors.Inordertowork,thesamewiringconventionmustbeusedthroughouttheentiresite.Version«B»iscurrentlythemostwidelyused.
Single-mode:Typeoffibrethattransmitssignalsbymeansofasinglelaserbeam.
Multi-mode:TypeoffibrethattransmitssignalsbymeansofamultiplebeamdeliveredbyLEDs.
nvp:NominalVelocityofPropagationofthesignalinatwistedpaircable.Specifiedbythemanufacturer.
permanent link:TwistedpairlinkwithanRJ45motorsocketateachend.(e.g.:fromthepatchpaneltothewallsocket)
poe:(PoweroverEthernet)communicationprotocolforcarryingelectricalpowerinadditiontodata.(e.g.:ThePoEIPcamerasarepoweredand networked by a single cable)
poep:(PoweroverEthernetPlus)improvedPoEprotocolabletotransmitmorepower
Campus distributor:Wiringcabinetlocatedinthecampusequipmentroomforinterconnectingseveralbuildings
building distributor:Locatedinthebuildingequipmentroom,itinterconnectsallthefloorsofthebuilding
Floor distributor:Locatedinthebuildingequipmentroom,servestodistributethewiringthroughoutthefloor
voip:(VoiceoverInternetProtocol),communicationprotocolforcarryingvoiceovertheEthernet
www.multimedia-connect.frFactory and HeadquartersMULTIMEDIA CONNECT 8, rue des Biches 74100 Ville la Grand France
Commercial departmentMULTIMEDIA CONNECT ZAC des Hauts de Wissous « Air Park de Paris »Bâtiment le Cormoran 3 rue Jeanne Garnerin 91320 WissousFrance T: +33 (0) 1 69 79 39 80 F: +33 (0) 1 64 48 29 84