FOR TECH. SERVICE, CALL 1-610-696-9040 INSTALLATION OPERATION TROUBLESHOOTING OWNER'S MANUAL THE ICEBREAKER 350 "SUPERLITE" THAWS FROZEN METAL WA- TER PIPES ELECTRICALLY IN MINUTES. SAVE TIME, LABOR AND MONEY! MODEL IB350 FORM WC5281

Upload: others

Post on 06-Jan-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: OWNER'S MANUAL - Systematics Inc.OWNER'S MANUAL THE ICEBREAKER 350 "SUPERLITE" THAWS FROZEN METAL WA-TER PIPES ELECTRICALLY IN MINUTES. ... of the ice will seep through the melted

FOR TECH. SERVICE, CALL 1-610-696-9040

INSTALLATIONOPERATIONTROUBLESHOOTING

OWNER'S MANUAL

THE ICEBREAKER 350"SUPERLITE" THAWS FROZEN METAL WA-TER PIPES ELECTRICALLY IN MINUTES.SAVE TIME, LABOR AND MONEY!

MODEL IB350

FORM WC5281

Page 2: OWNER'S MANUAL - Systematics Inc.OWNER'S MANUAL THE ICEBREAKER 350 "SUPERLITE" THAWS FROZEN METAL WA-TER PIPES ELECTRICALLY IN MINUTES. ... of the ice will seep through the melted

MANUFACTURER’S LIMITED WARRANTY

This equipment is warranted against defects in materi-als and workmanship for a period of 2 YEARS from the dateof purchase.

Should it become defective for such reason, the Manu-facturer will repair it without charge, if it is returned to theManufacturer’s factory, freight prepaid. This warrantydoes not cover: (1) failure due to normal wear and tear; (2)damage by accident, force majeure, improper use, ne-glect, unauthorized repair or alteration; (3) anyone otherthan the original purchaser.

THIS LIMITED WARRANTY IS IN LIEU OF ALLOTHER WARRANTIES, EXPRESS OR IMPLIED. THEMANUFACTURER SHALL NOT BE LIABLE FOR ANYINJURY TO PERSONS, INCLUDING DEATH; OR LOSSOR DAMAGE TO ANY PROPERTY, DIRECT OR CON-SEQUENTIAL, INCLUDING, BUT NOT LIMITED TO,LOSS OF USE, ARISING OUT OF THE USE, OR THEINABILITY TO USE, THE PRODUCT. THE USER AS-SUMES ALL RISK AND LIABILITY WHATSOEVER INCONNECTION WITH THE USE OF THE PRODUCT,AND BEFORE DOING SO, SHALL DETERMINE ITSSUITABILITY FOR HIS INTENDED USE, AND SHALLASCERTAIN THE PROPER METHOD OF USING IT.

SOME STATES DO NOT ALLOW LIMITATIONS ONHOW LONG AN IMPLIED WARRANTY LASTS, OR THEEXCLUSIONS OR LIMITATIONS OF INCIDENTAL ORCONSEQUENTIAL DAMAGES. SO THE ABOVE LIMI-TATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU.THIS WARRANTY GIVES YOU SPECIFIC LEGALRIGHTS, AND YOU MAY HAVE OTHER RIGHTS WHICHMAY VARY FROM STATE TO STATE.

TABLE OF CONTENTSINTRODUCTION .................................................... 1SPECIFICATIONS .................................................. 2INSTALLATION ...................................................... 2OPERATION .......................................................... 3TROUBLESHOOTING ........................................... 8

Systematics, Inc. 1025 Saunders Ln. West Chester, Pa. 19380

Page 3: OWNER'S MANUAL - Systematics Inc.OWNER'S MANUAL THE ICEBREAKER 350 "SUPERLITE" THAWS FROZEN METAL WA-TER PIPES ELECTRICALLY IN MINUTES. ... of the ice will seep through the melted

Systematics, Inc. 1025 Saunders Ln. West Chester, Pa. 19380 1

THE PIPE THAWING PROCESS

When electrically thawing a sec-tion of water pipe, it is onlynecessary to heat the pipe enough tomelt a thin film of ice on the insideof the pipe. The warmer water, understandard pressure, on the one sideof the ice will seep through themelted film and very quickly meltthe rest of the ice, causing a flowout of the open faucet on thedownstream side. If operated prop-erly, the pipe thawing machine willmelt the ice and cause the water tostart to flow in about 10 minutes(see "APPROXIMATE" thawing times onpage 4).

NOTICESince copper pipe will not heatup as fast as iron pipe, allowabout 30 percent longer thawingtime.

INTRODUCTIONTHAWING FROZEN PIPES ELECTRICALLY

A frozen water pipe can be thawedvery quickly by passing low volt-age, high current AC electricitythrough it. This method works onsteel or copper pipes even when theyare buried in the ground or con-cealed in the walls of buildings.This method DOES NOT work on plasticpipes because they will not conductelectricity. The method requiresthat there be unfrozen water, understandard pressure, on one side ofthe frozen section of pipe and anopen faucet on the other side.

Thawing pipes electrically hasbeen shown to be more convenient andsafer than other methods of thawingpipes including the following:

METHOD REMARKS

Open flame Lack of control.Uses dangerous gasor other flammableliquids.Risk of fire.

Hot Water Slow.Lack of control.

Arc Welder Large power sourceis required tosupply needed highvoltage.Arc can meltpipes.Hazard of highvoltage shock tooperator.Damage to welder.Risk of fire.

ElectricPipe Thawer Uses safe low

voltage.Easy to use.No flame or arcwhen usedproperly.

STANDARDWATER

PRESSUREOPENFAUCET

ICEBREAKER

FROZEN AREA

WATER UNDERSTANDARD PRESSURE

SEEPS THROUGHMELTED FILM

FROZENAREA

IMPORTANTThe Icebreaker 350 comesequipped with a built-in ther-mal protector. When theIcebreaker's internal tempera-ture reaches a certain point,automatic shut down will occur.

FIGURE 1. THE THAWING PROCESS

Page 4: OWNER'S MANUAL - Systematics Inc.OWNER'S MANUAL THE ICEBREAKER 350 "SUPERLITE" THAWS FROZEN METAL WA-TER PIPES ELECTRICALLY IN MINUTES. ... of the ice will seep through the melted

2 Systematics, Inc. 1025 Saunders Ln. West Chester, Pa. 19380

DESCRIPTIONThe Systematics Icebreaker 350

is a compact, light weight, elec-tric pipe thawing machine intendedfor use by professional plumbersand for light industrial use. It isdesigned for use with 1/2 inch to 1inch copper or iron pipe up to 100feet in length. The unit is pro-tected by a internal thermal switchand a 20 amp circuit breaker.Standard cables are two 20 foot #2AWG with clamps to fit 1/2 inch to1 inch pipe. Two 50 foot #2/0 AWGcables may be used for long lengthsof pipe.

NOTELonger cables must also belarger in AWG size. If smallerdiameter cables are used, cur-rent (amperage) will be lim-ited.

SPECIFICATIONSPART NO. IB350

INPUT:Voltage 115V ACPhase singleFrequency 50/60 HzCurrent 20 AmpsInput Cable 15 feet

OUTPUT:Voltage 5V ACCurrent-(Maximum) 375 Amps

PIPE THAWING CAPACITY:Pipe Size 1 inchLength 100 feet (max.)

DIMENSIONS:Height 8 inchesWidth 8 inchesDepth 8 inchesWeight 31 pounds

RECOMMENDED CABLES:two 20 ft. #2 AWG (2)20-2two 50 ft. #2/0 AWG* (2)50-2/0

*Longer cables must also be largerin AWG size.

IB350 FEATURESThe following features are lo-

cated on the front of the IB350.

A.CARRYINGHANDLE

B.OUTPUTLUGS

C.INSULATEDKNOBS

FIGURE 2. FRONT VIEW

D.INDICATORLAMP

E.CIRCUITBREAKER

F.INPUTCORD

INSTALLATIONThe Icebreaker 350 is portable

and can be positioned in any loca-tion convenient to the frozen pipeand available input power. A 115volt AC grounded 20 amp circuit isrequired. If it is necessary to usean extension cord, it should be aheavy-duty 3 prong grounded conduc-tor type.

A. CARRYING HANDLEHeavy-duty constructed handlefor easy lifting of the IB350.

B. OUTPUT LUGSTerminals allow quick installa-tion and removal of pipe thawingcable assemblies.

C. INSULATED KNOBSNo wrench required for easycable removal.

D. INDICATOR LAMPIlluminates when the circuitbreaker is turned "ON".

E. CIRCUIT BREAKERPrimary power switch and over-load protection device.

F. INPUT CORDFifteen foot heavy-duty cordwith grounded plug.

Page 5: OWNER'S MANUAL - Systematics Inc.OWNER'S MANUAL THE ICEBREAKER 350 "SUPERLITE" THAWS FROZEN METAL WA-TER PIPES ELECTRICALLY IN MINUTES. ... of the ice will seep through the melted

Systematics, Inc. 1025 Saunders Ln. West Chester, Pa. 19380 3

WARNINGIf the wiring is grounded in twoplaces, such as, at a barn anda house, a parallel low voltagecurrent may be establishedthrough the grounded neutralconductor. If so, it could gethot and could start a fire ineither building. Disconnectall grounds at either end of theelectrical wiring system.

Disconnect all appliances toprevent blowing house fuses oroverheating the house wiring.

Do not connect the Icebreakerto the 115 volt power until allpipe connections have beenmade. See "Operation" section.

THAWING DIRECT LINES

Uncoil the pipe thawing cables.Connect them to the Icebreaker andthe pipe to be thawed, at thenearest convenient spots that willplace the frozen section BETWEENthe clamps. Place the clamps atleast 15 feet apart to preventoverheating the machine and cables.

15 FEET(MINIMUM)

OPENFAUCET

ICEBREAKER UNFROZENLINE AT

STANDARDWATER

PRESSURE

TO 115VACINPUT

NOTEGood connections are neces-sary. Before connecting thecables, clean all pipes bysanding with coarse emerycloth. Make sure all connec-tions are tight to preventoverheating or arcing at theclamps. When the connectionsare good, the pipe and cableswill vibrate to the touch. Donot use cables coiled up orplaced on steel objects asheating in the pipe will bereduced.

WARNINGThe cables get hot during op-eration so keep them off rugsand finished floors that may bedamaged by the heat.

After both pipe connections aremade, plug the power input cord intothe 115 volt AC receptacle. Be surethe Icebreaker 350 is turned "ON".Monitor the equipment during thepipe thawing operation.

FIGURE 4. STANDARD HOOKUP

FROZEN AREA

OPERATIONFirst, isolate the frozen sec-

tion of pipe. Inside a house, thisis done by opening faucets and backtracing the pipes. The frozen sec-tion will usually be in the outsidewalls, near doors or windows, or incrawl spaces under floors. If allwater outlets in the house fail tooperate, the line from the curbvalve to the house could befrozen(see "THAWING HOUSE SERVICEPIPES" on page 4). (continued on following page)

FIGURE 3. PARALLEL GROUND

FROZEN AREA

PARALLELGROUND WIRE

ICEBREAKER

BAR

N

HO

USE

Page 6: OWNER'S MANUAL - Systematics Inc.OWNER'S MANUAL THE ICEBREAKER 350 "SUPERLITE" THAWS FROZEN METAL WA-TER PIPES ELECTRICALLY IN MINUTES. ... of the ice will seep through the melted

4 Systematics, Inc. 1025 Saunders Ln. West Chester, Pa. 19380

WARNINGA small empty pipe in thecircuit may get very hot beforea larger pipe will thaw. Thiscould melt the solder in acopper line or set fire tonearby combustible materials.

The following chart indicatesthe "APPROXIMATE" thawing timesunder "ideal" condition.

PIPE TO BE THAWED:Size- 3/4 to 1 inchType- copper or steel

NOTICEThe Icebreaker relies upon aconductive material, (i.e.bronze, copper, iron), for op-eration. So plastic or PVC pipecan not be thawed using thistype of equipment.

CABLES USED: (2)20-2Size- #2 AWGLength- 20 feet (each)

"APPROXIMATE"PIPE THAWINGLENGTH CURRENT TIME20 feet 350 Amps 5 min.40 feet 300 Amps 8 min.

CABLES USED: (2)50-2/0Size- #2/0 AWGLength- 50 feet (each)

"APPROXIMATE"PIPE THAWINGLENGTH CURRENT TIME20 feet 300 Amps 8 min.40 feet 270 Amps 10 min.50 feet 240 Amps 12 min.60 feet 220 Amps 15 min.80 feet 200 Amps 20 min.100 feet 180 Amps 25 min.

THAWING HOUSE SERVICE PIPES

House service pipes usually canbe thawed by connecting one cable tothe exposed pipe in the kitchen orbasement and the other cable to thecurb service. At the curb, make theconnection to the valve at thebottom of the service riser using acurb key. The adjustable groundlevel cover probably does not makea good connection to the valve.

MAIN

HO

USE

FROZEN AREA VALVE

SERVICERISER

ICEBREAKER

FIGURE 5. HOUSE SERVICE PIPE

NOTICEThe curb key must make a excel-lent connection or heating ofthe key will be the only result.

THAWING HOT WATER HEATING SYSTEMS(WINTER/SUMMER HOOKUP)

This unit is intended for use insituations where there is a directpipeline from an unfrozen, highpressure pipeline to an open fau-cet. It may be used on hot waterheating systems. However, the de-sign of these systems presentsproblems which may make theIcebreaker’s use ineffective.

1. Because these systems use lowpressure pumps, more heating isrequired before the warmer watercan seep past the ice and con-tinue the thawing process.

CURB KEY

Page 7: OWNER'S MANUAL - Systematics Inc.OWNER'S MANUAL THE ICEBREAKER 350 "SUPERLITE" THAWS FROZEN METAL WA-TER PIPES ELECTRICALLY IN MINUTES. ... of the ice will seep through the melted

Systematics, Inc. 1025 Saunders Ln. West Chester, Pa. 19380 5

2. Because the pipes in the systemare interconnected electri-cally, the resistance heatingfrom the Icebreaker current cantake several paths through thepipes and will not be concen-trated in the frozen section.The heat developed in the frozensection will be only 1/2 to 1/3of the heat developed by theIcebreaker. There may or may notbe enough heat to thaw the pipe.

3. There is little hope of thawingpipes in systems using cast ironradiators, large iron pipes orgravity circulation.

FROZEN AREA (ZONE 1)

NON-FROZEN (ZONE 2)

THAWING COPPER BASEBOARD SYSTEMS

To thaw copper pipe baseboardsystems, attach the clamps directlyto the pipe and not to the sheetmetal pipe covers. Covers should beremoved or lifted up so they willnot touch the heating pipe. Thecopper pipe should be insulatedfrom any metal hangers or supports.

HEATER

PUMP

CARDBOARDINSULATION

FIGURE 6. HEATING SYSTEMS

If the setup is correct and thereis no thaw, the final solution is toopen the pipes so all the heat andpressure is concentrated in onefrozen zone at a time, as shown inFigure 6.

FIGURE 7. BASEBOARD SYSTEM

ICEBREAKER

INSULATION

FROZEN AREA

(continued on following page)

PREVENT REFREEZING OF PIPES

Prevent refreezing by takingsteps to prevent the pipe fromcooling below 32 degrees F. Insu-late all cracks and openings, wrappipes with thermostatically con-trolled heating tape and let watertrickle on cold nights (usually aflow of one gallon per hour isenough to prevent freezing).

THAWING PIPES WITH TWO ICEBREAKERS

The heating current in the pipemay be checked with a standard ACclamp-on "Amprobe®" meter, thistest instrument is highly recom-mended for best results. Currentshould be between 200 and 400 amps.If the current is less than 200amps, a second Icebreaker 350 can beused to increase the current.

1. SEPARATE AND CAP ALL UNFRO-ZEN ZONES.

2. SEPARATE FROZEN ZONE.3. PUT CARDBOARD INSULATION

BETWEEN PIPE ENDS.4. TURN ON HEATER, PUMP AND

ICEBREAKER. COLLECT THAW-ING WATER IN A CONTAINER.

5. SHUT OFF EVERYTHING.QUICKLY CONNECT PIPES.

6. CHECK HEAT IN ALL ZONES.

ICEBREAKER

Page 8: OWNER'S MANUAL - Systematics Inc.OWNER'S MANUAL THE ICEBREAKER 350 "SUPERLITE" THAWS FROZEN METAL WA-TER PIPES ELECTRICALLY IN MINUTES. ... of the ice will seep through the melted

6 Systematics, Inc. 1025 Saunders Ln. West Chester, Pa. 19380

THAWING PIPES WITH TWO ICEBREAKERS(Cont.)

The second Icebreaker 350 willrequire a second 20 amp 115 volt ACcircuit. Just as with jumping autobatteries, the polarity must becorrect for the second unit tooperate properly.

WARNINGOperation of a second unit withthe polarity incorrect willburn up the machines and willnot heat the pipe.

DETERMINING THE POLARITY

Since these units have an alter-nating current output, the instan-taneous polarity can not be ob-served. A test procedure must befollowed to determine if the polar-ity is correct.

TEST FOR POLARITY - SET UP #1(Parallel)

Make the two pipe connections onone side of the pipe and plug in bothunits. Momentarily touch the othertwo clamps together and notice theamount of spark. If there is littleor no spark, the polarity is correctand the clamps may be attached tothe pipe. If there is a strongspark, the polarity is wrong. Cor-rect the polarity by (A) turningover one of the 115V plugs OR (B)interchanging the cable leads onone of the Icebreaker units. Testagain for the amount of spark.

TEST FOR POLARITY - SET UP #2(Series)

Make all connections except theclamp on one end of the pipe.Momentarily touch the clamp to thepipe and observe the spark. If thereis a strong spark, the polarity iscorrect and the clamp can be con-nected to the pipe. If there islittle or no spark, the polarity iswrong. Correct the polarity by (A)turning over one of the 115V plugsOR (B) interchanging the cableleads on one of the Icebreakerunits. Retest the spark strength.

WARNINGDue to the chance of a dischargeof an electrical spark duringthe polarity test. Extreme cau-tion should be exercised.Please remove all flammablematerials, gases, etc., fromthe immediate area. Wear heavygloves and eye protection.

FIGURE 8. #1 PARALLEL CONNECTIONS(BEST FOR LARGE DIAMETER PIPE)

20 FEET (MIN.)

FROZEN AREA

ICEBREAKER #2

ICEBREAKER #1

Page 9: OWNER'S MANUAL - Systematics Inc.OWNER'S MANUAL THE ICEBREAKER 350 "SUPERLITE" THAWS FROZEN METAL WA-TER PIPES ELECTRICALLY IN MINUTES. ... of the ice will seep through the melted

Systematics, Inc. 1025 Saunders Ln. West Chester, Pa. 19380 7

IMPORTANT REVIEWDO- use short cables.DO- unwind the cables.DO- connect clamps to unfrozen

pipe on either side offrozen section.

DO- clean pipe and make goodconnections.

DO- make connections to pipebefore plugging in the Ice-breaker.

DO- open faucets so moving wa-ter can help thaw pipe.

DO- use only heavy duty exten-sion cords.

DO- disconnect other appli-ances while using the Ice-breaker.

DO- disconnect all electricalgrounds attached to thaw-ing area(i.e. telephone,cable TV, etc.).

DO- make sure there is waterpressure at one side offrozen section.

DO- attach clamps to pipe cor-rectly.

DO- watch for overheating andfires.

DO- prevent refreezing.DO NOT- lay cables across

floors or carpeting.DO NOT- leave cables wound up.DO NOT- make quick connections

to dirty pipe.DO NOT- move clamps while cur-

rent is flowing.DO NOT- leave machine unat-

tended.DO NOT- leave machine "ON"

over night.

Two Icebreakers, properly con-nected, will double the thawingaction. If more heat is required, alarger Icebreaker unit and quali-fied operator will be necessary.

40 FEET (MIN.)

ICEBREAKER #1 ICEBREAKER #2

FROZEN AREA

FIGURE 9. #2 SERIES CONNECTIONS(BEST FOR LONG LENGTHS OF PIPE)

Page 10: OWNER'S MANUAL - Systematics Inc.OWNER'S MANUAL THE ICEBREAKER 350 "SUPERLITE" THAWS FROZEN METAL WA-TER PIPES ELECTRICALLY IN MINUTES. ... of the ice will seep through the melted

8 Systematics, Inc. 1025 Saunders Ln. West Chester, Pa. 19380

TROUBLE SHOOTINGFOR TECH. SERVICE, CALL 1-610-696-9040

The Trouble Shooting Chart is a guide in identifying and correctingpossible troubles which may occur when operating this equipment.

FAULT POSSIBLE CAUSE REMEDY

Cables stay cold Line fuse is blown. Replace fuse.-pipe does not Machine circuit breaker Turn on circuit breaker.thaw (no current is "OFF".flow). Poor connection by Clean pipe where clamp

cable clamps. are attached.Both clamps are not on Put clamps on same pipe.

same pipe.Thermal protector is Allow unit to cool and

tripped. retry.Some pipe in line is Need a complete circuit

connected with rubber for electric current.insulated couplings.(not a complete circuit)

There is some plastic Need a complete circuitpipe in the line (not for electric current.a complete circuit)

Solder joint has been Need a complete circuitpushed apart by ice. for electric current.(not a complete circuit)

Cables get warm Clamps attached to metal Attach clamps directlybut not hot cover and not directly to pipe.-pipe does not to pipe.thaw. Poor connection by cable Clean pipe where clamps

clamp. are attached.Use of longer than Use larger AWG cables

standard cables which -longer cables mustare not larger in also be larger.AWG size.

Cables get hot No water pressure Thaw water pressure-pipe does not -source is frozen. source.thaw. No water pressure Turn on pump-water

-pump is not operating. pressure is required.Clamps do not cover all Reposition clamps so all

of frozen area. of frozen area isbetween them.

Pipes interconnected Separate frozen pipeelectrically-not from non-frozen pipe.enough heat isconcentrated in thefrozen section.

Thawing hot water systems Separate frozen zonewith several zones from non-frozen zone.-not enough heat isconcentrated in frozensection.

THE ICEBREAKER 350 RELIES ON CURRENT FLOW FOR PROPER OPERATION.PLEASE EQUIP YOURSELF WITH AN AC CLAMP-ON "AMPROBE®" METER FOR CUR-RENT MONITORING PURPOSES.