owner’s manual - spaparts123.net · owner’s manual index marquis spas. page 4 the following...

37
WELCOME TO THE SPA LIFE! Please enjoy your new Marquis spa, but think safety first. Read your Owner’s Manual in its entirety before installing your spa and encourage all spa users to do the same. More than just common sense, this Owner’s Manual provides vital safety and operational information. CARE AND ENJOYMENT GUIDE A Care and Enjoyment guide is located in the back of the manual. It features important water treatment and maintenance information, as well as spa en- hancement products that are available at your Marquis dealer. Keep this guide handy to answer all your spa questions. We sincerely hope your spa life is a pleasant experi- ence. If problems should arise, contact your Marquis dealer first. Or contact Marquis Corp. at any of the following: Email: [email protected] Web: www.marquisspas.com Marquis Corp. 596 Hoffman Road Independence, OR 97351 PAGE 1 owner’s manual MARQUIS SPAS

Upload: others

Post on 19-Oct-2019

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

WELCOME TO THE SPA LIFE!Please enjoy your new Marquis spa, but think safetyfirst. Read your Owner’s Manual in its entirety beforeinstalling your spa and encourage all spa users to dothe same. More than just common sense, thisOwner’s Manual provides vital safety and operationalinformation.

CARE AND ENJOYMENT GUIDEA Care and Enjoyment guide is located in the backof the manual. It features important water treatmentand maintenance information, as well as spa en-hancement products that are available at yourMarquis dealer. Keep this guide handy to answer allyour spa questions.

We sincerely hope your spa life is a pleasant experi-ence. If problems should arise, contact your Marquisdealer first. Or contact Marquis Corp. at any of thefollowing:

Email: [email protected]: www.marquisspas.com

Marquis Corp.596 Hoffman RoadIndependence, OR 97351

PAGE 1

owner’s manual

MARQUIS SPAS

Page 2: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

SERIAL NUMBER LOCATIONYou will find the serial number on the UnderwritersLaboratories tag in the equipment area.

PLEASE FILL OUT AND KEEP FOR FUTUREREFERENCE

Name of Purchaser__________________________________

Date of Purchase ___________________________________

Address ___________________________________________

City _____________________State ____Zip Code _______

Signature __________________________________________

Telephone _________________________________________

Spa Model/Color ___________________________________

Spa Serial # ________________________________________

Pack Serial # _______________________________________

Dealer’s Name _____________________________________

Dealer’s Address ___________________________________

City _______________________State____Zip Code________

Telephone ___________________________________________

Every effort has been made to ensure the accuracyof this manual. However, Marquis Spas® reservesthe right to improve its product without notice. Thiscould create a minor variation between this manualand the actual product you receive. We apologizefor any inconvenience this may cause.

PAGE 2

product reference

MARQUIS SPAS

Page 3: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

IMPORTANT SAFETY INSTRUCTIONS120V, Cord Connected Models ....................................................... 4240V, Permanently Installed or Converted Models ....................... 5All Spa Models .................................................................................. 5-7Personal Safety ................................................................................. 8-9

INSTALLATION INSTRUCTIONSLocation ............................................................................................. 10-11Filter Cartridges ................................................................................. 12Electrical Requirements ....................................................................13-14

STARTING YOUR SPA ...................................................................... 15-17

OPERATING YOUR SPA ...................................................................18

SPA MODELS ....................................................................................................19-37Spirit ..................................................................................................................... 20-21Mirage ................................................................................................22-23Wish ................................................................................................... 24-25Quest ................................................................................................. 26-27Destiny ............................................................................................... 28-29Reward ............................................................................................................... 30-31Euphoria ............................................................................................................. 32-33Silver Anniversary Reward............................................................................ 34-35Silver Anniversary Euphoria.......................................................................... 36-37

SPA CONTROL OPERATIONSpirit, Mirage, and Wish ................................................................................. 38-41Quest, Destiny, Reward, Euphoria, Silver Anniversary Reward,and Silver Anniversary Euphoria.................................................................. 42-46

EQUIPMENT DIAGRAMSSpirit, Mirage, and Wish ................................................................................. 47Quest and Destiny .......................................................................................... 48Reward, Escape, Euphoria,...........................................................................49Silver Anniversary Reward, and Silver Anniversary Euphoria............. 50

TROUBLESHOOTING ................................................................................... 51-53LCD Diagnostic Messages ...........................................................................52-53

MARQUIS CARE AND ENJOYMENT GUIDE .....................................54-67

MAINTENANCE ................................................................................................68-74

SPA ENHANCEMENTS ................................................................................ 75-76

PAGE 3

owner’s manual index

MARQUIS SPAS

Page 4: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

PAGE 4

The following instructions are required to be printed by UnderwritersLaboratories (UL) as a condition of the listing of this product. They containimportant safety information. We strongly encourage you to read andapply them.

IMPORTANT SAFETYINSTRUCTIONSWHEN INSTALLING AND USING THIS ELECTRICAL EQUIP-MENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BEFOLLOWED, INCLUDING THE FOLLOWING:

1. READ AND FOLLOW ALLINSTRUCTIONS

2. WARNING: To reduce the risk of injury, do not permit children to usethis product unless closely supervised at all times.

3. DANGER: RISK OF CHILD DROWNING. Extreme caution must beexercised to prevent unauthorized access by children. To avoid acci-dents, ensure that children cannot use the spa or hot tub unless theyare supervised at all times.

120 VOLT, CORD CONNECTED MODELS4. DANGER: RISK OF INJURY. Connect only to a grounded source.5. Do not bury the power cord.6. WARNING: To reduce the risk of electric shock, replace a damaged cord

immediately.7. A ground terminal (pressure wire connector) is provided on the surface

of the control box inside the equipment compartment. This connectorshould be bonded with a minimum No. 8 AWG (8.4mm2) solid copperwire between this unit and any metal ladders, metal water pipes, metalenclosures of electrical equipment, conduit, or metal equipment withinfive feet (1.5m) of the spa. If the spa is located on a reinforced concretepad, the reinforcing steel should also be bonded to the ground terminal.

8. WARNING: Your spa is equipped with a ground fault circuit interrupter(GFCI) on the end of the power supply cord. Before each use of thespa, with the plug connected to the power supply and the unit operat-ing, press the “test” button. The unit should stop operating and theGFCI power indicator will go out. Wait thirty seconds and then reset theGFCI by pressing the “Reset” button. The GFCI power indicator will turnon, restoring power to the spa. If the interrupter does not perform in thismanner, it is an indication of an electrical malfunction and the possibilityof an electric shock. Disconnect the plug from the receptacle until thefault has been identified and corrected.

safety instructions

MARQUIS SPAS

Page 5: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

240 VOLT, PERMANENTLY INSTALLED OR CONVERTED MODELS9. A ground terminal is provided on the terminal block (TB-1, terminal 7)

located inside the control box. To reduce the risk of electric shock,connect this terminal to the grounding terminal of your electrical serviceor supply panel with a continuous green, insulated copper wire. Thewire must be equivalent in size to the circuit conductors supplying theequipment. In addition, a bonding terminal (pressure wire connector) isprovided on the outside of the control box for bonding to local groundpoints. To reduce the risk of electric shock, this connector should bebonded with a No. 8 AWG (8.42mm2) solid copper wire to any metalladders, water pipes, or other metal within five feet (1.5m) of the spato comply with local requirements.

10. Your spa uses ground fault circuit interrupters in the electrical sub-panel.Before each use of the spa and with the unit operating press the Testbutton on each breaker. The switch should click over to the “Trip”position. Wait thirty seconds and reset each GFCI breaker by switchingit completely off and then completely on. The switch should then stayon. If either of the interrupters does not perform in this manner, it is anindication of an electrical malfunction and the possibility of an electricshock. Disconnect the power until the fault has been identified and corrected.

ALL SPA MODELS11. Install the spa so proper drainage is provided.12.DANGER: RISK OF ELECTRIC SHOCK. Install the spa at least five

feet (1.5m) away from metal surfaces, in accordance with the NationalElectric Code ANS/NMFPA70-1993. Each metal surface must bepermanently connected to a minimum No. 8 (8.42mm2) solid copperconductor attached to the wire bonding connector on the terminal boxprovided for this purpose.

13.DANGER: RISK OF ELECTRIC SHOCK. Do not permit any appliance,such as a light, telephone, radio, or television, etc. within five feet (1.5m)of the spa or hot tub.

14.WARNING: To reduce the risk of injury:• The water in the spa should never exceed 104°F (40°C). Water

temperatures between 100°F (38°C) and 104°F (40°C) are consideredsafe for a healthy adult. Lower water temperatures are recommendedfor extended use (exceeding 10 minutes) and for young children.

• Since excessive water temperatures have a high potential for causingfetal damage during the early months of pregnancy, pregnant orpossibly pregnant women should limit spa water temperatures to100°F (38°C).

• Before entering a spa, the user should measure the water temperaturewith an accurate thermometer since the tolerance of temperature-regulating devices may vary as much as +/- 5°F (3°C).

• The use of drugs, alcohol, or medication before or during spa use maylead to unconsciousness with the possibility of drowning.

• Persons suffering from obesity or with a medical history of heartdisease, low or high blood pressure, circulatory system problems, ordiabetes should consult a physician before using the spa.

PAGE 5

safety instructions

MARQUIS SPAS

Page 6: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

• Persons using medications should consult a physician before using aspa since some medication may induce drowsiness while othermedication may affect heart rate, blood pressure, and circulation.

15.DANGER: TO REDUCE THE RISK OF INJURY TO PERSONS. Donot remove the suction fittings.

16.DANGER: RISK OF INJURY: Never operate a spa if the suctionguard(s) is broken or missing. Never replace a suction guard with onerated less than the flow rate marked on the original suction guard. Thesuction guard(s) in the spa are sized to match the specific water flowcreated by the pump. Should the need arise to replace the suctionguard(s) or the pump, be sure that the flow rates are compatible.

17.DANGER: Children are especially sensitive to hot water. At no timeshould children have unsupervised access to the spa. Children must notbe allowed to climb onto the spa cover. All Marquis spas are equippedwith a locking cover that meets the ASTM F1346-91 Standard for SafetyCovers. Always lock the child resistant locks after using the spa for yourchildren’s safety.

18.SAVE THESE INSTRUCTIONS.WARNING: Children should not use spas or hot tubs without adultsupervision.WARNING: Do not use spas or hot tubs unless all suction guard(s) areinstalled to prevent body and hair entrapment.WARNING: Do not use drugs or alcohol before or during the use of aspa or hot tub to avoid unconsciousness and possible drowning.WARNING: People using medications and/or having an adversemedical history should consult a physician before using a spa.WARNING: The use of alcohol, drugs, and medication can greatlyincrease the risk of fatal hyperthermia.WARNING: Before entering the spa or hot tub measure the watertemperature with an accurate thermometer.WARNING: Water temperature in excess of 104°F (40°C) may beinjurious to your health.WARNING: Prolonged immersion in a spa or hot tub may be injurious toyour health.WARNING: People with infectious diseases should not use a spa.WARNING: Pregnant or possibly pregnant women should consult aphysician before using a spa or hot tub.WARNING: To avoid injury, exercise care when entering and exiting thespa or hot tub.WARNING: Do not use a spa or hot tub immediately followingstrenuous exercise.CAUTION: Maintain water chemistry in accordance withmanufacturer’s instructions.

PAGE 6

safety instructions

MARQUIS SPAS

Page 7: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

SAFETY INSTRUCTIONS FOR FRENCH SPEAKING SPA OWNERS

AVERTISSEMENT: Ne pas placer d’appareil électrique (luminaire,téléphone,radio, téléviseur, etc.) moins de 1.52 m de cette cuve derelaxation.AVERTISSEMENT: Ne pas laisser les enfants utiliser une cuve de relax-ation sans surveillance.AVERTISSEMENT: Pour éviter que les cheveux ou une partie du corpspuissent être aspirés, ne pas utiliser une cuve de relaxation si les grilles deprise d’aspiration ne sont pas toutes en place.AVERTISSEMENT: Pour éviter l’évanouissement et la noyade éventuelle,ne prendre ni drogue ni alcool avant d’utiliser une cuve de relaxation niquand on s’y trouve.AVERTISSEMENT: Les personnes qui prennent des médicaments ou ontdes problemès de santé devraient consulter un médecin avant d’utiliserune cuve de relaxation.AVERTISSEMENT: La consommation d/alcool ou de drogue augmenteconsidérablement les risques d’hyperthermie motrelle dans une cuve derelaxation.AVERTISSEMENT: Avant d’utiliser une cuve de relaxation mesurer latempérature de l’eau l’aide d’un thermométre précis.AVERTISSEMENT: Il peut être dangereux pour la santé de se plongerdans de l’eau plus de 40°C.AVERTISSEMENT: L’utilisation prolongée d’une cuve de relaxation peutêtre dangereuse pour la santé.AVERTISSEMENT: Les personnes atteintes de maladies infectieuses nedevraient pas utiliser une cuve de relaxation.AVERTISSEMENT: Les femmes enceintes, que leur grossesse soitconfirmée ou non, devraient consulter un médecin avant d’utiliser unecuve de relaxation.AVERTISSEMENT: Pour éviter des blessures, user de prudence enentrant dans une cuve de relaxation et en sortant.AVERTISSEMENT: Ne pas utiliser une cuve de relaxation immédiatementaprés un exercice fatigant.ATTENTION: La tenteur de l’eau en matières dissoutes doit êtreconforme aux directives du fabricant.

PAGE 7

safety instructions

MARQUIS SPAS

Page 8: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

PERSONAL SAFETYProlonged immersion in hot water can result in HYPERTHERMIA, adangerous condition which occurs when the internal temperature of thebody reaches a level above normal (98.6°F, 37°C). The symptoms ofhyperthermia include dizziness, fainting, drowsiness, lethargy, and a bodytemperature above 98.6°F (37°C). The physical effects of hyperthermiainclude unawareness of impending hazard, failure to perceive heat, failureto recognize the need to exit the spa, physical inability to exit the spa, fetaldamage in pregnant women, and unconsciousness resulting in a danger ofdrowning.

WARNING: The use of alcohol, drugs, or medication can greatly increasethe risk of fatal hyperthermia in hot tubs and spas.

Persons taking medications which induce drowsiness such as tranquilizers,antihistamines, or anticoagulants should not use the spa. Pregnant womenand persons with a medical history of heart disease, diabetes, or highblood pressure should consult a physician before using the spa.

PAGE 8

safety instructions

MARQUIS SPAS

Page 9: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

PERSONAL SAFETY DO’s:• Be sure your spa is connected to the power supply correctly – only use

a licensed electrical contractor.• Shut off power supply (unplug 120V models) before draining the spa

or servicing the electrical components.• Test the Ground Fault Circuit Interrupter (GFCI) monthly.• Always test the water temperature with an accurate thermometer

before entering the spa to be sure that it’s a safe temperature.• Remember that wet surfaces can be very slippery. Take care when

entering and exiting the spa.• Lock the DuraCover when the spa is not in use, whether it is empty or

full of water.• Keep the water clean and sanitized with correct chemical care.• Turn on the jets when adding ANY chemicals to the spa water.• Clean the filter cartridge(s) monthly to remove debris and mineral

buildup which affects the performance of the hydrotherapy jets,limits the flow, or trips the high limit thermostat which will turn off theentire spa.

PERSONAL SAFETY DO NOT’s:• Don’t use the spa with the equipment compartment door removed.• Don’t use the spa for more than 10 minutes of time at water tempera-

tures in excess of 102°F (39°C).• Don’t allow the jet pump(s) to operate for an extended period of time

with the cover in place. Extended pump operation causes a slowheat buildup due to water friction. The spa equipment controls areequipped with a built-in safety timer that automatically shuts off thejet pump(s) after 15 minutes of continuous operation should it havebeen left on inadvertently.

• Don’t operate the spa at any time with the filter cartridges removed.• Don’t lift or drag the cover by using the tie-down straps; always lift and

carry by using the external handles.• Don’t store chemicals in the spa’s equipment compartment.• Don’t hesitate to call your Marquis Spas dealer with any questions or

maintenance concerns.

PAGE 9

safety instructions

MARQUIS SPAS

Page 10: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

LOCATIONFor your portable spa to function properly and safely,it must be located on a hard, flat, level surface.Inground spas require special installation techniquesand should be planned in conjunction with your spadealer. Improper installation can result in structuraldamage to the spa and the voiding of your spawarranty. Items to discuss with your dealer include:Local construction codes, electrical service require-ments, serviceability of equipment, present under-ground obstructions such as gas, water, and tele-phone lines, safety measures such as fences andlocks, and visibility of the spa installation from thehome, street, and neighbors.

• Allow for sufficient water drainage around the spato help preserve the equipment and supportstructure. This includes indoor installations.

• A filled spa can weigh up to 4,000 pounds and thelocation should support the weight of the filled spa.

• Locate the equipment compartment where it willbe accessible. Your spa MUST be installed topermit access for servicing the equipment aboveand/or below any decks or floors. Access isessential and must allow adequate room for service.

• Leave access to the circuit breakers in the subpanel (240V models) or to the interrupter switch(GFCI, 120V models) on the end of the power cord.

• Be sure the spa is level and in the final positionBEFORE filling with water. Check for power cords,tools, and hoses that may be caught underneaththe spa.

• IMPORTANT: DO NOT LET AN EMPTY SPAREMAIN EXPOSED TO DIRECT SUNLIGHT.Spa surface temperatures can reach in excess of150°F (65°C) if left exposed to the sun. Significantdamage can occur if this is allowed to happen,including warping and blistering of the surface.Damage, that occurs as a result of this exposure,is not covered under the warranty.

• CAUTION: Never try to move a spa that has notbeen fully drained. To do so could result in dam-age to the spa and physical injury to the mover.

PAGE 10

installation instructions

MARQUIS SPAS

Page 11: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

OUTDOOR AND PATIO INSTALLATIONTo install the spa outdoors, we recommend areinforced concrete pad at least four inches thick.The reinforcing material should be attached to a #8AWG bonding wire per national and localelectrical code.

If you place the spa on the ground, even tempo-rarily, place concrete pavers under the entire bottomof the spa. The concrete pavers should be a leasttwo inches thick and level across the entire surface.The spa will inevitably settle and not remain level onthis surface, thus it’s important to get it onto a solidfoundation as soon as possible.

DECK INSTALLATIONBe sure the deck can support the weight of yourfilled spa by checking the deck’s maximum loadcapacity. Consult a qualified building contractor orstructural engineer. Minimum requirement is 100pounds per square foot.

INDOOR INSTALLATIONThere are special requirements if you place your spaindoors. Flooring material must provide adequatetraction when wet. Proper drainage is essential toprevent water puddling. To avoid increased humidityyou need to provide proper ventilation to the area.The addition of a ventilation system is recommended.

PAGE 11

installation instructions

MARQUIS SPAS

Page 12: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

SHUT-OFF VALVESYour spa is equipped with shut-off valves (seeEQUIPMENT DIAGRAM) that shut off the water flowto the equipment system for dealer service. Attimes, a new spa or one that has recently beenserviced, may have the shut-off valves partiallyclosed which can restrict the water flow and hinderjet performance. Be sure the valves are fully open.

FREEZE PROTECTIONWhen a freeze condition is detected (which occurswhen the temperature in the heater housing dropsto 55°F, (13°C) for 240V models; to 40°F (4°C) for120V models) the jet pump(s) is automaticallyactivated. In areas with extremely cold winterconditions, your spa should be fine as long as it isleft running at normal operating temperatures. Forextra protection see your dealer for an optionalfreeze sensor. If you plan to turn the spa off, followthe instructions in this manual (see SUSPENDEDUSE OR WINTERIZING YOUR SPA).

OVERHEATINGIn the case of extended hot weather, the spa watertemperature may reach and maintain 104°F to 106°F(40°C to 41°C) or higher. This is due to the ambienttemperature and the full insulation in the spa cabi-net. You may have the option of shortening thepump-run time. See SPA CONTROL OPERATION foravailable options.

FILTER CARTRIDGE(S)Your portable spa is equipped with the ConstantClean Filtration system. Depending on your spamodel, it features one or two Vortex filters.

NOTE: It is very important that the components ofthese filtration systems be installed properly in theproper part of the spa.

1. Hold the Vortex filter cartridge and center it inthe opening of the filter housing.

2. Use the filter handle and turn the filter cartridgeclockwise to screw it in place. (Use caution notto overtighten as damage may occur tothreads and is not covered under warranty.)

3. Grasp the edge of the dome-shaped Vortexfilter top. Center it over the ring and gently snapin place.

PAGE 12

installation instructions

Shut-off valve inopen position

1) Center filtercartridge over canister

2) Screw filtercartridge in place

3) Snap Vortex filter topin place

MARQUIS SPAS

Page 13: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

SUCTION GUARDSThe suction guard(s) in the footwell of your spa is anopening through which the jet pump(s) draws water.Suction fittings are equipped with a safety guard.Suction through the fittings can be strong. Thesafety guard(s) must remain in place and undam-aged. A fitting with a damaged guard(s) can bedangerous, especially to small children or peoplewith long hair. Should any part of the body becomedrawn to a fitting, turn the jet pump(s) off immedi-ately. Long hair should be restrained in a bathingcap, never allow it to float freely in the spa. Replaceany missing or damaged suction guard(s).

NOTE: It is normal for the flow rates of the suctionfittings to vary from strong to barely noticeable.

ELECTRICAL REQUIREMENTSIt is the responsibility of the spa owner to ensurethat all electrical connections are made in accor-dance with all electrical codes in effect at the timeof installation.

240 Volt:All connections must be made in accordance withthe wiring diagram found on the inside of the controlbox cover. Connections must be made with copperconductors only – do not use aluminum wiring withthis system. All conductors, circuit breakers, and/orfuses must be sized in accordance to the totalamperage load as specified:

• Permanently connected• Rated 240V, 60 Hz, 50A, three wires (#6

copper) plus ground (#8 AWG copper)• Fuse or circuit breaker size: 50 amp

This equipment is designed to operate on 60Hzalternating current only at a voltage of 240 (+ or -).Units to be operated at 240V must have all connec-tions made by a qualified electrician in accordancewith all electric codes in effect at the time of installa-tion. All 240V units require four wires (line 1, line 2,neutral, and ground). Refer to the label at theterminal block.

NOTE: Ensure the GFCI is properly installed. Failureto do so may result in spa malfunction or damagewhich is not warranted.

PAGE 13

installation instructions

Safety guard ofsuction fitting mustremain in place.

240V electricaldiagram

MARQUIS SPAS

220-240 VOLT AC, 60HzNOTE: USE COPPER CONDUCTORS ONLY

PO

WE

R IN

PU

TS

TO

CO

NTR

OL B

OA

RDNEUTRAL

WHITE

HOTBLACK

HOTRED

GROUND/EARTHGREEN

TB1

TB2

TB3

Page 14: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

A pressure wire connector is located on the exteriorof the control box. This pressure wire connectorshould be bonded with at least #8 AWG (8.42mm2,#6 in Canada) copper wire to any metal ladder,metal water pipe, common bonding grid (reinforcedconcrete slab, ground plate beneath the spa), or anyother metal within five feet of the spa.

120 Volt:120V units must only be connected to a properlygrounded, grounding type 15 amp dedicated recep-tacle. 120V equipment is designed to operate on60Hz alternating current only at a voltage of 120,12.5 amp. maximum load. Only use the cord pro-vided with the spa, do not use an extension cord.

To Convert 120V to 240V:All connections must be made by a licensedelectrician.

1. Disconnect power by unplugging from recep-tacle and remove cord from terminal block.

2. Move both red wires TB-1 to TB-4 as indicatedby gray area.

3. Move the Heater Mode selector (J23) on theControl Board from (20A) to (50A) position.Ground Fault Circuit Interrupters (GFCI), #8145,are available from your Marquis dealer.

4. Refer to 240V installation, page 13.

PAGE 14

installation instructions

120V electrical diagram

MARQUIS SPAS

Convert 120V to 240Velectrical diagram

Page 15: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

START-UP PROCEDUREYour spa is equipped with solid-state ComfortControls specific to your spa model. Please see SPACONTROL OPERATION for your specific spa model.

To start your spa, you need a spa water test kit andan underwater thermometer. It is important to followeach of these steps when starting your spa. Onceyou have completed the following steps, refer to theinstructions in your start-up kit for proper start-upwater maintenance, or see MARQUIS CARE ANDENJOYMENT GUIDE, Marquis SpaCare Start-up Kit.

NOTE: Your spa has been filled and test-run at thefactory. The first time your spa is filled with water,some discoloration from residual test water mayappear. This will disappear when the spa is com-pletely filled and the filtration system is functioning.Test the water for the proper chemical balance andadjust as necessary. Marquis SpaCare products arerecommended. (See WATER TREATMENT.)PROPER CHEMICAL BALANCE IS IMPORTANTfor your safety and the longevity of your spa.

THERAPY PUMP(S)Allow the spa to circulate on high-speed (see SPACONTROL OPERATION) for four to five minutes todischarge air from the plumbing system. Do notexpect hot water immediately from the jets; theheater will take several hours to heat the water.

Start-up procedure for Spirit, Mirage, and Wish:1. Place spa on a hard, flat, level surface. Make

sure the power supply is off.2. Make sure the suction guard(s) in the footwell

are in place and undamaged.3. Open the equipment door. Screw the pump

plug (supplied in packet) into the face of thepump. (See EQUIPMENT DIAGRAM.) Close thedrain valve in the equipment bay. Screw the plugin the hose connector located on the externalDuraBase. Tighten all disconnects and open allshut-off valves.

4. Install filter cartridge. (See INSTALLATIONINSTRUCTIONS, Filter Cartridge.)

5. Fill the spa with water to two-thirds of the wayup the Vortex skimmer opening. The use of aFill Filter (part #5039) is recommended,especially in areas with high mineral content inthe water.

6. Turn the power on and wait five seconds.PAGE 15

starting your spa

Fill spa with water totwo-thirds of the wayup the Vortex skimmeropening.

MARQUIS SPAS

Close drain valve inequipment bay (shownin open position).

Screw plug in hoseconnector.

Screw pump plug intoface of pump.

Page 16: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

7. After a few seconds the spa should have waterflowing from the jets. If the pump has notprimed and the water is not flowing from the jetsafter two minutes TURN OFF POWER TOTHE SPA and vent air from the pumps byslightly opening the pump unions.

8. The factory default setting for water temperatureis 102°F (39°C). Use the TEMP pad on thecontrol panel to set the water temperature tothe desired level. (See TEMPERATURE DISPLAYAND ADJUSTMENT.) Your spa will heat at therate of approximately one degree per hour for120V systems and five degrees per hour for240V systems.

Start-up procedure for Quest, Destiny, Reward,Euphoria, Silver Anniversary Reward, and SilverAnniversary Euphoria:

1. Place spa on a hard, flat, level surface. Makesure the power supply is off.

2. Make sure the suction guard(s) in the footwellare in place and undamaged.

3. Open the equipment door. For Reward, Escape,and Euphoria, check to make sure the freezeline between pump one and pump two isproperly connected. For Quest and Destiny,screw the pump plug (supplied in packet) intothe face of the pump. (See EQUIPMENT DIA-GRAM.) Close the drain valve in the equipmentbay. Screw the plug in the hose connectorlocated on the external DuraBase. Tighten alldisconnects and open all shut-off valves.

4. Install filter cartridges. (See INSTALLATIONINSTRUCTIONS, Filter Cartridge(s).)

5. Fill the spa with water to two-thirds of the wayup the Vortex skimmer openings. The use of aFill Filter is recommended, especially in areaswith high mineral content in the water.

6. Turn the power on.7. Your spa is now in “pump priming” mode and a

“Pr” message displays in the LCD window ofthe control panel. While in this mode the spaappears idle, which lasts approximately four tofive minutes if not exited manually. To exitmanually, press the TEMP pad.

8. At this time the spa should have water flowingfrom the jets. If the pump has not primed andthe water is not flowing from the jets after twominutes TURN OFF POWER TO THE SPA andvent air from the pumps by slightly opening thepump unions. After turning the power on again,the spa initiates a new priming mode. Repeatsteps above.PAGE 16

starting your spa

Fill spa two-thirds ofthe way up the Vortexskimmer opening.

Screw pump plug intoface of pump.

Vent air by slightlyopening pump unions.

MARQUIS SPAS

Close drain valve inequipment bay (shownin open position).

Screw plug in hoseconnector.

Page 17: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

9. The system requires approximately two minutes of water flow to determine the water tempera- ture. After two minutes of water flow, the tem- perature is displayed as actual water tempera- ture. After you have manually exited the priming mode (or allowed the spa to automatically exit) the LCD window momentarily displays 102°F (39°C) and then the display switches to - - °F.

10. The factory default setting for water tempera- ture is 102°F (39°C). Use the TEMP pad on the control panel to set the water temperature to the desired level. (See SPA CONTROL OPERA- TION, Temperature Display And Adjustment.) Your spa heats at the rate of approximately five degrees per hour for 240V systems.

DURACOVERWhen the spa is not in use, the DuraCover shouldbe kept on the spa to retain the water’s heat and tokeep out dirt, leaves, etc. Your heater maintains aconstant water temperature between uses.

For your safety and convenience, the cover isequipped with adjustable straps, safety locks, andhandles. Use the exterior handles to remove andreplace your cover. Marquis suggests that you usethe safety locks to help keep out unintended usersand prevent covers from being blown off in windyconditions. For high wind areas, Secure Straps (part#8140) are available. DuraLift (part #8225) cover liftsare also available to assist you in cover removal. (SeeSPA ENHANCEMENTS at back of this manual.)

PAGE 17

starting your spa

MARQUIS SPAS

Use TEMP pad to setwater temperature.

DuraCover helpsmaintain a constantwater temperature.

Page 18: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

MAXIMUM THERAPY JETTING SYSTEM

PERSONAL THERAPY JETSThis small jet provides a targeted stream of water.

CASCADE NECK JETSThe Cascade Neck jets are turned on and off (whenthe jet pump is on) using the small teardrop neck jetcontrol lever.

POWER BOOST JETThe direction of water flow can be changed byredirecting the central nozzle. The water flow can beadjusted by turning the jet face using the four tabs.

POWER SWIRL JETThis rotating jet provides a firm, broad area ofcircular massage action. The water flow can beadjusted by turning the jet face using the four tabs.

CYCLO BOOST JETLarge, versatile jet flows in a straight stream. Thewater flow can be adjusted by turning the jet faceusing the four tabs.

CYCLO SWIRL JETLarge, versatile jet can flow straight or can be madeto rotate by pushing the nozzle to the side (push inthe direction indicated by the point of its teardropshape). The water flow can be adjusted by turningthe jet face using the four tabs.

HYDROKINETIC (HK40™) JETHigh-flow jet strategically positioned within the spato provide passive and whole body massage.

TRI-ZONE CONTROLUse this control to divert water to each of the threezones. (See TRI-ZONE CONTROL.)

AIR CONTROLUse this control to increase or decrease the air flowto the various jets.

PAGE 18

operating your spa

Power Swirl Jet

Cyclo Swirl Jet

HK40 Jet

Tri-Zone Control

Air Control

MARQUIS SPAS

Page 19: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

spa models

PAGE 19

MARQUIS SPAS

The following section provides valuable informationregarding your specific spa model, including location ofjets and components, and how to operate the jets withthe Tri-Zone control(s).

We have strived to make this information as conciseand easy to understand as possible. If you have anyquestions regarding your specific Marquis spa model,please contact your Marquis spa dealer, or you maycontact Marquis Spas by a method located on pageone of this Owner’s Manual.

Marquis Spas is celebrating 25years of manufacturing spaswith the development of twospecial spa models – SilverAnniversary Reward and SilverAnniversary Euphoria.

SPIRITMIRAGEWISH

QUESTDESTINYREWARD

EUPHORIASILVER ANNIVERSARY

REWARDSILVER ANNIVERSARY

EUPHORIA

Page 20: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

# Component Identification Qty.2 Power Boost Jets 63 Power Swirl Jets 26 Personal Therapy Jets 27 Cascade Neck Jets 38 HK40 Jets 89 Ozone Injector Fitting 110 Light 111 Air Control 112 Heat Sensor 113 Suction Fittings 214 Bather’s Control Panel 115 Auxiliary Jet Control Panel 116 Floor Drain 117 Filter Canister 119 Cascade Neck Jet Valve 120 Tri-Zone Control 121 Spa Frog® 122 Spa Frog return fitting 1

Physical Specifications SizeDimensions 60" x 84"Height 29"Interior Depth 28"Seating Positions 4Weight Dry/Lbs. 410Weight Full/Lbs. 1786Water Capacity/Gallons 165Total Therapy Jets 21

the spirit

Use the Bather’s

panel to set the

temperature,

select the

filtration, and

turn on the jets

and lights.

Use the auxiliary

Jet Control panel

to turn on jets.

This valve

controls the

water flow of

the Cascade

Neck jets.

Use the Tri-Zone

control to select

the jet zones.

14

15

19

20

PAGE 20

MARQUIS SPAS

2

22

2

10

11

13 13

14

15

9

7

7

7

16

17

19

12

88

8 8

8 8 88

3

32

2

6

6

20

TR

I-Z

ON

E S

EL

EC

TO

R

22

21

Page 21: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

ZONE 1Upper-,mid- andlower-backjets.*

ZONE 2Lower-body jets.*

ZONE 3Upper- andmid-backjets.*

spirit tri-zone control

PAGE 21

MARQUIS SPAS

*CascadeNeck jetsoperate inevery zone.

Page 22: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

# Component Identification Qty.2 Power Boost Jets 93 Power Swirl Jets 17 Cascade Neck Jets 38 HK40 Jets 89 Ozone Injector Fitting 110 Light 111 Air Control 112 Heat Sensor 113 Suction Fittings 214 Bather’s Control Panel 115 Auxiliary Jet Control Panel 116 Floor Drain 117 Filter Canister 119 Cascade Neck Jet Valve 120 Tri-Zone Control 121 Spa Frog® 122 Spa Frog return fitting 1

Physical Specifications SizeDimensions 77" x 77"Height 34"Interior Depth 32.5"Seating Positions 5Weight Dry/Lbs. 450Weight Full/Lbs. 2660Water Capacity/Gallons 265Total Therapy Jets 21

the mirage

Use the Bather’s

panel to set the

temperature,

select the

filtration, and

turn on the jets

and lights.

Use the auxiliary

Jet Control panel

to turn on jets.

This valve

controls the

water flow of

the Cascade

Neck jets.

Use the Tri-Zone

control to select

the jet zones.

14

15

19

20

PAGE 22

MARQUIS SPAS

88

8

8

2

2

2

2

2

3

7

7

7

9

10

11

12

13

13

14

16

17

20

1915

2 2

2 2

88

88

TR

I-ZO

NE

SE

LE

CT

OR

2122

Page 23: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

ZONE 1Upper-,mid- andlower-backjets.*

ZONE 2Lower-body jets.*

ZONE 3Upper- andmid-backjets.*

*CascadeNeck jetsoperate inevery zone.

mirage tri-zone control

PAGE 23

MARQUIS SPAS

Page 24: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

# Component Identification Qty.2 Power Boost Jets 83 Power Swirl Jets 27 Cascade Neck Jets 38 HK40 Jets 89 Ozone Injector Fitting 110 Light 111 Air Controls 212 Heat Sensor 113 Suction Fittings 214 Bather’s Control Panel 115 Auxiliary Jet Control Panel 116 Floor Drain 117 Filter Canister 119 Cascade Neck Jet Valve 120 Tri-Zone Control 121 Spa Frog® 122 Spa Frog return fitting 1

Physical Specifications SizeDimensions 77" x 77"Height 34"Interior Depth 32.5"Seating Positions 6Weight Dry/Lbs. 475Weight Full/Lbs. 2810Water Capacity/Gallons 280Total Therapy Jets 21

the wish

Use the Bather’s

panel to set the

temperature,

select the

filtration, and

turn on the jets

and lights.

Use the auxiliary

Jet Control panel

to turn on jets.

This valve

controls the

water flow of

the Cascade

Neck jets.

Use the Tri-Zone

control to select

the jet zones.

14

15

19

20

PAGE 24

MARQUIS SPAS

7

2

2

2

2

2

2

2

2

3

3

77

8 8

8

8

8

88

8

10

11

11

12

13

13

14

15

17

19

20

16

9

TRI-ZONE SELECTOR

22

21

Page 25: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

wish tri-zone control

PAGE 25

ZONE 1Upper-,mid- andlower-backjets.*

ZONE 2Lower-body jets.*

ZONE 3Whirlpooljets.*

*CascadeNeck jetsoperate inevery zone.

MARQUIS SPAS

Page 26: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

# Component Identification Qty.2 Power Boost Jets 83 Power Swirl Jets 24 Cyclo Boost Jets 16 Personal Therapy Jets 47 Cascade Neck Jets 38 HK40 Jets 89 Ozone Injector Fitting 110 Light 111 Air Controls 213 Suction Fitting 114 Bather’s Control Panel 115 Auxiliary Jet Control Panel 116 Floor Drain 117 Filter Canisters 219 Cascade Neck Jet Valve 120 Tri-Zone Control 121 Spa Frog® 122 Spa Frog return fitting 1

Physical Specifications SizeDimensions 77" x 84"Height 34"Interior Depth 32.5"Seating Positions 6Weight Dry/Lbs. 600Weight Full/Lbs. 3102Water Capacity/Gallons 300Total Therapy Jets 26

the quest

Use the Bather’s

panel to set the

temperature,

select the

filtration, heat

modes, and

turn on the jets

and lights.

Use the auxiliary

Jet Control panel

to turn on jets.

This valve

controls the

water flow of

the Cascade

Neck jets.

Use the Tri-Zone

control to select

the jet zones.

14

15

19

20

PAGE 26

MARQUIS SPAS

7

7

7

8

8

8

8

8

8

2

2

2

2

22

2

2

3

3

4

66

6 6

8

8

9

10

11

13

14

15

16

1717

11

19

20

TR

I-ZO

NE

SE

LE

CT

OR

102 F

2221

Page 27: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

quest tri-zone control

PAGE 27

ZONE 1Upper-,mid- andlower-backjets.*

ZONE 2Lower-body jets.*

ZONE 3Upper- andmid-backjets.*

*CascadeNeck jetsoperate inevery zone.

MARQUIS SPAS

Page 28: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

# Component Identification Qty.2 Power Boost Jets 83 Power Swirl Jets 17 Cascade Neck Jets 68 HK40 Jets 129 Ozone Injector Fitting 110 Light 111 Air Controls 213 Suction Fitting 114 Bather’s Control Panel 115 Auxiliary Jet Control Panel 116 Floor Drain 117 Filter Canisters 219 Cascade Neck Jet Valves 220 Tri-Zone Control 121 Spa Frog® 122 Spa Frog return fitting 1

Physical Specifications SizeDimensions 84" x 84"Height 34"Interior Depth 32.5"Seating Positions 7Weight Dry/Lbs. 700Weight Full/Lbs. 3702Water Capacity/Gallons 360Total Therapy Jets 27

the destiny

Use the Bather’s

panel to set the

temperature,

select the

filtration, heat

modes, and

turn on the jets

and lights.

Use the auxiliary

Jet Control panel

to turn on jets.

This valve

controls the

water flow of

the Cascade

Neck jets.

Use the Tri-Zone

control to select

the jet zones.

14

15

19

20

PAGE 28

MARQUIS SPAS

2

2

3

8

8

88

8

8

7

7

7

2 2

9

13

15

17 17

19

20

16

10

11 11

2

2

2

2

TRI-ZONE SELECTOR

8

8

8

8

8

8

7

7

7

14

19

22

21

102 F

Page 29: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

destiny tri-zone control

PAGE 29

ZONE 1Upper- andmid-back,lower-bodyjets.*

ZONE 2Lower-body jets.*

ZONE 3Upper-backjets.*

*CascadeNeck jetsoperate inevery zone.

MARQUIS SPAS

Page 30: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

# Component Identification Qty.2 Power Boost Jets 54 Cyclo Boost Jets 15 Cyclo Swirl Jets 16 Personal Therapy Jets 187 Cascade Neck Jets 38 HK40 Jets 169 Ozone Injector Fitting 110 Light 111 Air Controls 212 Heat Sensor 113 Suction Fittings 414 Bather’s Control Panel 115 Auxiliary Jet Control Panel 116 Floor Drain 117 Filter Canisters 219 Cascade Neck Jet Valve 120 Tri-Zone Controls 221 Spa Frog® 122 Spa Frog return fitting 1

Physical Specifications SizeDimensions 84" x 84"Height 34"Interior Depth 32.5"Seating Positions 6Weight Dry/Lbs. 740Weight Full/Lbs. 3659Water Capacity/Gallons 350Total Therapy Jets 44

the reward

Use the Bather’s

panel to set the

temperature,

select the

filtration, heat

modes, and turn

on the jets and

lights.

Use the auxiliary

Jet Control panel

to turn on jets.

This valve

controls the

water flow of the

Cascade Neck

jets.

Use the Tri-Zone

control to select

the jet zones.

14

15

19

20

PAGE 30

MARQUIS SPAS

2

2

2

2

2

5

4

10

13

13

13 13

16

17

17 20

88

8 8

8 8

88

88

11

19

2015

8

6

6

6

6

66

6

66

6

6

6 6

66

6

6

7

7

7

88

88

6

8

9

11

14

102 F

TR

I-Z

ON

E S

EL

EC

TO

R

TR

I-ZO

NE

SE

LE

CT

OR

2122

Page 31: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

reward tri-zone control

PAGE 31

ZONE 1Upper-,mid- andlower-backjets.*

ZONE 2Upper- andmid-backjets.*

ZONE 3Whirlpooljets.*

ZONE 4Upper-,mid- andlower-backjets.*

ZONE 5Lower-body jets.*

ZONE 6Whirlpooljets.*

*CascadeNeck jetsoperate inevery zone.

MARQUIS SPAS

Page 32: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

# Component Identification Qty.2 Power Boost Jets 113 Power Swirl Jets 25 Cyclo Swirl Jets 16 Personal Therapy Jets 167 Cascade Neck Jets 68 HK40 Jets 179 Ozone Injector Fitting 110 Light 111 Air Controls 213 Suction Fittings 414 Bather’s Control Panel 115 Auxiliary Jet Control Panel 116 Floor Drain 117 Filter Canisters 219 Cascade Neck Jet Valves 220 Tri-Zone Controls 221 Spa Frog® 122 Spa Frog return fitting 1

Physical Specifications SizeDimensions 90" x 90"Height 35.5"Interior Depth 34"Seating Positions 7Weight Dry/Lbs. 825Weight Full/Lbs. 4161Water Capacity/Gallons 400Total Therapy Jets 53

the euphoria

Use the Bather’s

panel to set the

temperature,

select the

filtration, heat

modes, and turn

on the jets and

lights.

Use the auxiliary

Jet Control panel

to turn on jets.

This valve

controls the

water flow of the

Cascade Neck

jets.

Use the Tri-Zone

control to select

the jet zones.

14

15

19

20

PAGE 32

MARQUIS SPAS

10

2

2

2

2

2

2 22

2

6

6

6

6

2

2

3

3

5

6

6

6

66

6

6

6

6

66

6

7

7

7

9

21

11

13 13

13 13

14

15

16

1717

19

20 20

8 8

88

8

8

8

8

8

8

8 8

8

88

8 8

7

7

7

19

TRI-ZONE SELECTOR

102

F

TRI-ZONE SELECTOR

11

22

Page 33: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

euphoria tri-zone control

PAGE 33

ZONE 1Upper-,mid- andlower-backjets.*

ZONE 2Lower-body jets.*

ZONE 3Whirlpooljets.*

ZONE 4Upper-,mid- andlower-backjets.*

ZONE 5Upper- andmid-backjets.*

ZONE 6Whirlpooljets.*

*CascadeNeck jetsoperate inevery zone.

MARQUIS SPAS

Page 34: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

# Component Identification Qty.2 Power Boost Jets 144 Cyclo Swirl Jets 27 Cascade Neck™ Jets 68 HK40™ Jets 229 Ozone Injector Fitting 110 Light 111 Air Controls 213 Suction Fittings 414 Bather’s Control Panel 115 Auxiliary Jet Control Panel 116 Floor Drain 117 Filter Canisters 219 Cascade Neck Jet Valves 220 Tri-Zone Controls 221 Spa Frog® 122 Spa Frog Return Fitting 1

Physical Specifications SizeDimensions 84" x 84"Height 35.5"Interior Depth 34"Seating Positions 6Weight Dry/Lbs. 740Weight Full/Lbs. 3659Water Capacity/Gallons 350Total Therapy Jets 44

the silver anniversary reward

Use the Bather’s

panel to set the

temperature,

select the

filtration, heat

modes, and turn

on the jets and

lights.

Use the auxiliary

Jet Control panel

to turn on jets.

This valve

controls the

water flow of the

Cascade Neck

jets.

Use the Tri-Zone

control to select

the jet zones.

14

15

19

20

PAGE 34

MARQUIS SPAS

102 F

14

10

13

13

1313

9

16

17

17

19

19

11

11

20

20

15

77

77

77

4

4 2

22

2

22

22

2

2

2 2

2 2

8

8

8

8

88

88

8

8

88

88

88

8

8

8

8

8

8

22

21

Page 35: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

silver anniversary reward tri-zone control

PAGE 35

ZONE 1Lower-body jets.*

ZONE 2Upper-,mid- andlower-backjets.*

ZONE 3Upper-backjets.*

ZONE 4Lower-body jets.*

ZONE 5Upper-,mid- andlower-backjets.*

ZONE 6Upper-backjets.*

*CascadeNeck jetsoperate inevery zone.

MARQUIS SPAS

Page 36: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

# Component Identification Qty.2 Power Boost Jets 163 Power Swirl Jets 27 Cascade Neck™ Jets 68 HK40™ Jets 249 Ozone Injector Fitting 110 Light 111 Air Controls 213 Suction Fittings 414 Bather’s Control Panel 115 Auxiliary Jet Control Panel 116 Floor Drain 117 Filter Canisters 219 Cascade Neck Jet Valves 320 Tri-Zone Controls 221 Spa Frog® 122 Spa Frog Return Fitting 1

Physical Specifications SizeDimensions 90" x 90"Height 35.5"Interior Depth 34"Seating Positions 7Weight Dry/Lbs. 825Weight Full/Lbs. 4161Water Capacity/Gallons 400Total Therapy Jets 48

the silver anniversary euphoria

Use the Bather’s

panel to set the

temperature,

select the

filtration, heat

modes, and turn

on the jets and

lights.

Use the auxiliary

Jet Control panel

to turn on jets.

This valve

controls the

water flow of the

Cascade Neck

jets.

Use the Tri-Zone

control to select

the jet zones.

14

15

19

20

PAGE 36revised

MARQUIS SPAS

10

2

2

2

2 22

8 8

8

2

2

3

3

8

8

8

8

8

8

8

8

88

7

7

9

21

11

13 13

13 13

14

15

16

1717

19

20 20

8

88

8

7

7

19

TRI-ZONE SELECTOR

102 F

TRI-ZONE SELECTOR

11

22

2

11

88

2

2

2

8

877

2

2

2

28

8 8

Page 37: owner’s manual - SpaParts123.net · owner’s manual index MARQUIS SPAS. PAGE 4 The following instructions are required to be printed by Underwriters Laboratories (UL) as a condition

silver anniversary euphoria tri-zone control

PAGE 37

ZONE 1Upper-,body jets.*

ZONE 2Upper- andmid-bodyjets.*

ZONE 3Lower-body jets.*

ZONE 4Upper-,body jets.*

ZONE 5Upper- andmid-bodyjets.*

ZONE 6Lower-body jets.*

*CascadeNeck jetsoperate inevery zone.

MARQUIS SPAS