owner s manual - klimaire...heating will resume after defrost is complete. notes for turning off...

23
Owner s Manual Split type wall mounted air - conditioner ^ Please read this owners manual carefully and thoroughly before operating the unit! Take care of this manual for future reference.

Upload: others

Post on 04-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Owner s Manual - Klimaire...Heating will resume after defrost is complete. Notes for turning off When the air conditioner is turned off, the main controller will automatically decide

Owner’s ManualSplit type wall mountedair-conditioner

^ Please read this owners manual carefully andthoroughly before operating the unit!

Take care of this manual for future reference.

Page 2: Owner s Manual - Klimaire...Heating will resume after defrost is complete. Notes for turning off When the air conditioner is turned off, the main controller will automatically decide

CONTENTS

Operation and maintenanceSafety Precautions 1

Notices for use 6

Names of each part 8

Clean and care 9

Troubleshooting 10

Installation serviceNotices for installationInstall indoor unit 15

Install outdoor unit 18

Check after installation and test operation 21

Note: All the pictures in this manual are just schematic diagrams,the actual is the standard.

Page 3: Owner s Manual - Klimaire...Heating will resume after defrost is complete. Notes for turning off When the air conditioner is turned off, the main controller will automatically decide

Safety Precautions

Incorrect installation or operation by not following theseinstructions may cause harm or damage to people,properties, etc.The seriousness is classified by the following indications:

WARNING CAUTIONThis symbol indicates This symbol indicates thethe possibility of death possibility of injury oror serious injury. damage to properties.

WARNING

This appliance can be used by children aged from 8 yearsand above and persons with reduced physical, sensory ormental capabilities or lack of experience and knowledge ifthey have been given supervision or instruction concerninguse of the appliance in a safe way and understand thehazards involved. Children shall not play with the appliance.Cleaning and user maintenance shall not be made bychildren without supervision.Only for the AC with CE-MARKING)

This appliance is not intended for use by persons (includingchildren with reduced physical, sensory or mentalcapabilities, or lack of experience and knowledge, unlessthey have been given supervision or instruction concerninguse of the appliance by a person responsible for their safety.Children should be supervised to ensure that they do notplay with the appliance.(Except for the AC with CE-MARKING)

- 1 -

Page 4: Owner s Manual - Klimaire...Heating will resume after defrost is complete. Notes for turning off When the air conditioner is turned off, the main controller will automatically decide

Safety precautions

The air conditionermust be grounded.Incomplete ground¬

ing may result inelectric shocks.

Do not connect the earth wireto the gas pipeline, waterpipeline, lightning rod, ortelephone earth wire.

Always switch offthe device and cutthe power supplywhen the unit is notin use for long timeso as to ensuresafety.

Take care not letthe remote controland the indoor unitwatered or beingtoo wet.

NO!

Otherwise, it may cause shortcircuit.

If the power supplycable is damaged, itmust be replaced bythe manufacture orits service agent ora similar qualifiedperson.

Don't cut off mainpower switch duringoperating or withwet hands.

‘NO!

It may cause electric shock.

Don't share thesocket with otherelectric appliance.

Otherwise, it may causeelectric shock even fireand explosion.

Always switch offthe device and cutthe power supplybefore performingany maintenanceor cleaning.

OFF

Otherwise, it may causeelectric shock or damage.

Don't pull thepower cable .

The damage of pulling powercord will cause serious electricshock.

An earth leakagebreaker with ratedcapacity must beinstalled to avoidpossible electricshocks.

- 2 -

Page 5: Owner s Manual - Klimaire...Heating will resume after defrost is complete. Notes for turning off When the air conditioner is turned off, the main controller will automatically decide

Safety Precautions

Don't install airconditioner in aplace where there isflammable gas orliquid. The distancebetween themshould above 1

It may cause fire even explosion.

Don't use liquid orcorrosive cleaningagent wipe the airconditioner andsprinkle water orother liquid either.

NO!Doing this may cause electricshock or damage to the unit.

Don't attempt torepair the airconditioner byyourself.

NO!

Incorrect repairs may causefire or explosion. Contact aqualified service technicianfor all service requirement.

Don't use airconditioner inlightning stromweather.

Power supply should be cutin time to prevent theoccurrence of danger.

Don't put hands orany objects into theair inlets or outlets.

(NO!)

This may cause personalinjury or damage to the unit.

Please note whetherthe installed stand isfirm enough or not.

.. .. ^If it is damaged, it may leadto the fall of the unit andcause the injury.

Don't block air inletor air outlet.

Otherwise, the cooling orheating capacity will beweakened, even causesystem stop operating.

Don’t let the airconditioner blowagainst the heaterappliance.

Otherwise it will lead toincomplete combustion, thuscausing poisoning.

The applianceshall be installedin accordance withnational wiringregulations.

- 3 -

3.3ft.

3.3ft

Page 6: Owner s Manual - Klimaire...Heating will resume after defrost is complete. Notes for turning off When the air conditioner is turned off, the main controller will automatically decide

Safety Precautions

This product contains fluorinated greenhouse gases.

Refrigerant leakage contributes to climate change.Refrigerant with lower global warming potential (GWP) wouldcontribute less to global warming than a refrigerant withhigher GWP, if leaked to the atmosphere. This appliancecontains a refrigerant fluid with a GWP equal to [2088]. Thismeans that if 1 kg of this refrigerant fluid would be leaked tothe atmosphere, the impact on global warming would be[2088] times higher than 1 kg of CO2 , over a period of 100years. Never try to interfere with the refrigerant circuityourself or disassemble the product yourself and alwaysask a professiona.

The specification of the fuse are printed on the circuit board,such as: 3.15A/250V AC, etc.

WEEE WarningMeaning of crossed out wheeled dustbin:Do not dispose of electrical appliances asunsorted municipal waste, use separatecollection facilities.Contact you local government for informationregarding the collection systems available.If electrical appliances are disposed of in ^landfills or dumps, hazardous substancescan leak into the groundwater and get intothe food chain, damaging your health andwell-being.When replacing old appliances with new ones, the retaileris legally obligated to take back your old appliance fordisposals at least free of charge.

- 4 -

Page 7: Owner s Manual - Klimaire...Heating will resume after defrost is complete. Notes for turning off When the air conditioner is turned off, the main controller will automatically decide

Safety Precautions

CAUTION

Don’t open thewindows and doorsfor long time whenthe air conditioneris running.

Don’t stand on thetop of the outdoorunit or place heavythings on it.

Don’t use the airconditioner for otherpurposes, such asdrying clothes,preserving foods,etc.

Otherwise, the cooling or heatingcapacity will be weakened.

m NOT

This cloud cause personalinjuries or damage the unit.

(NO!

11Don't apply the coldair to the body for along time.

NO!

Set the suitabletemperature.

It is recommendedthat the temperaturedifference betweenindoor and outdoortemperatureshould not betoo large.

^If your airconditioner is notfitted with a supplycord and a plug, anall-pole switch mustbe installed in thefixed wiring and thedistance betweencontacts should be

It will deteriorate yourphysical conditions andcause health problems.

Appropriate adjustments of thesetting temperature can preventthe waste of electricity.

no less than 3.0 mm.

If your air conditioner is permanently connected to the fixedwiring, a residual current device (RCD) having rated residualoperating current not exceeding 30 mA should be installed inthe fixed wiring.

The power supply circuit should have leakage protector and airswitch of which the capacity should be more than1.5 times ofthe maximum current.

Regarding the installation of the air conditioners, please referto the below paragraphs in this manual.

- 5 -

0.1in.

Page 8: Owner s Manual - Klimaire...Heating will resume after defrost is complete. Notes for turning off When the air conditioner is turned off, the main controller will automatically decide

Notices for use

The conditions of unit can’ t normally run

Within the temperature range provided in following table, the air conditioner maystop running and other anomalies may arise.

CoolingOutdoor

>43 "C(Apply to T1)

>52°C(Apply to T3)Indoor <180

HeatingOutdoor

>240<-70

Indoor >270

When the temperature is too high, the air conditioner may activate the automaticprotection device, so that the air conditioner could be shut down.When the temperature is too low, the heat exchanger of the air conditioner mayfreeze, leading to water leakage or other malfunction.In long-term cooling or dehumidification with a relative humidity of above 80%(doors and windows are open), there may be water condenses or dripping nearthe air outlet.T1 and T3 refer to ISO 5151.

Notes for heatingThe fan of the indoor unit will not start running immediately after the heating isstarted to avoid blowing out cool air.When it is cold and wet outside, the outdoor unit will develop frost over the heatexchanger which will compromise the heating capacity. This is when the airconditioner will start defrost.During defrost, the air conditioner will stop heating for about 5-12 minutes.Vapor may come out from the outdoor unit during defrost. This is not a malfunction,but a result of fast defrost.Heating will resume after defrost is complete.

Notes for turning off

When the air conditioner is turned off, the main controller will automatically decidewhether to stop immediately or after running for dozens of seconds with lowerfrequency and lower air speed.

- 6 -

109.4°F (Apply to T1)

125.6°F (Apply to T3)

64.4°F75.2°F19.4°F

80.6°F

Page 9: Owner s Manual - Klimaire...Heating will resume after defrost is complete. Notes for turning off When the air conditioner is turned off, the main controller will automatically decide

Notices for useEmergency operation

If the remote controller is lost or broken,use force switch button to operate theair conditioner.If this button is pushed with the unit OFF,the air conditioner will operate in Auto mode.If this button is pushed with the unit ON,the air conditioner will stop running.

Force switch

Airflow direction adjustment

1. Use up-down swing and left-right swingbuttons on the remote controller to adjustthe airflow direction. Refer to the operationmanual of the remote controller for detail.

2. For models without left-right swing function,the fins has to be moved manually.

Note: Move the fins before the unit is in operation,or your finger might be injured.Never place your hand into the air inlet oroutlet when the air conditioner is in operation.

ATTENTION

_

If the equipment emissions cannot meet the technical requirement of IEC 61000-3-3,following Attention should be take care.Attention: This appliance can be connected only to a supply with system impedance nomore than Zmax. In case necessary, please consult your supply authority for systemimpedance information.

Product Type Zmax Product Type Zmax

ASTW-H30Q4/#-IQ 0.021 ASW-H28G5A4/#R1-C5 0.296

ASW-H28G5B4/#R1-C5 0.116 ASW-H18E1B4/#R1-C 0.296

ASW-H18E1B4/#R1-C5S 0.296

#=LK700,LF,LH,LI,LM,LN,LR,LU,LS,LD,LP, LQ,LB,LO,LC,LE,LL,LV800,LT,LW,LZ ,ULK700,ULF,ULH,ULM,ULN,ULI,ULS,ULU,ULD,ULP,ULR, ULQ,ULB,ULO,ULC,ULE,ULL,ULV800,ULT,ULW,ULZ,QLK700,QLF,QLH,QLM,QLN,QLI,QLS,QLU,QLD,QLP,QLR,QLQ,QLB,QLO,QLC,QLE,QLL,QLV800,QLT,QLW,QLZ,DA,DB,DC,DE,DF,DH,DI

- 7 -

Page 10: Owner s Manual - Klimaire...Heating will resume after defrost is complete. Notes for turning off When the air conditioner is turned off, the main controller will automatically decide

Names of each part

Air inlet grille

Panel

Air filter

Air louverAir vent

Indoor unit

Air inletForce switch

Air outlet

Pipe protectionring

Remote controller

Outdoor unit

Air outlet grille

Power cable —

Air outlet

Connecting pipe

Drain hose

Note: All the pictures in this manual are just schematic diagrams, the actual is the standard.Plug, WIFI function, Negative-ion function, and Vertical and horizontal swing function bothare optional,the actual unit shall prevail.

- 8 -

Page 11: Owner s Manual - Klimaire...Heating will resume after defrost is complete. Notes for turning off When the air conditioner is turned off, the main controller will automatically decide

Clean and careWarning

•Before the cleaning of the air conditioner, it must be shut down and theelectricity must be cut off for more than 5 minutes, otherwise there mightbe the risk of electric shocks.

•Do not wet the air conditioner, which can cause an electric shock. Makesure not to rinse the air conditioner with water under any circumstances.

•Volatile liquids such as thinner or gasoline will damage the air conditionerhousing, therefore please clean the housing of air conditioner only with softdry cloth and damp cloth moistened with neutral detergent.

•In the course of the using, pay attention to cleaning the filter regularly, toprevent the covering of dust which may affect the effect. If the serviceenvironment of the air conditioner is dusty, correspondingly increase thenumber of times of cleaning. After removing the filter, do not touch the finpart of the indoor unit with the finger, so as to avoid scratching it.

Clean the panel

When the panel of the indoor unit is contaminated, clean itgently with a wrung towel using tepid water below 45°Cand do not remove the panel while cleaning.

Clean the air filter

Remove the air filter

1. Use both hands to open the panel for an angle from both ends of the panel inaccordance with the direction of the arrow.

2. Release the air filter from the slot and remove it.

Clean the Air FilterUse a vacuum cleaner or water to rinse filter, andif the filter is very dirty (for example, with greasy dirt),clean it with warm water (below 45°C) with milddetergent dissolved in, and then put the filter inthe shade to dry in the air.

- 9 -

,113°F

113°F

Page 12: Owner s Manual - Klimaire...Heating will resume after defrost is complete. Notes for turning off When the air conditioner is turned off, the main controller will automatically decide

Clean and careClean the air filter

Mount the Filter1. Reinstall the dried filter in reverse order of removal, then cover and lock the panel.

Check before use

1. Check whether all the air inlets and outlets of the units are unblocked.2. Check whether there is blocking in the water outlet of the drain pipe, and

immediately clean it up if any.3. Check the ground wire is reliably grounded.4. Check whether the remote control batteries are installed, and whether the power

is sufficient.5. Check whether there is damage in the mounting bracket of the outdoor unit, and

if any, please contact our local service center.

Maintain after use

1. Cut off the power source of the air conditioner, turn off the circuit breaker and removethe batteries from the remote control.

2. Clean the filter and the unit body.3. Remove the dust and debris from the outdoor unit.4. Check whether there is damage in the mounting bracket of the outdoor unit, and if

any, please contact our local service center.

TroubleshootingACaution

* Do not repair the air conditioner by yourself as wrong maintenance may cause electricshock or fire, please contact the authorized service center and let the professionalsconduct the maintenance, and checking the following items prior to contacting formaintenance can save your time and money.

- 10 -

Page 13: Owner s Manual - Klimaire...Heating will resume after defrost is complete. Notes for turning off When the air conditioner is turned off, the main controller will automatically decide

TroubleshootingPhenomenon Troubleshooting

Air conditioner cannot operate at all.

•Has the power been shut down? •Is the wiring loose?

•Is voltage too high or too low ?(measured by professionals)Does it reach the set time for start up?

•Does the circuit protection device trip?

Remote controlleris not available.

Is the remote controller out of effective distance to the indoor unit?Are there any obstructions between the controller and thesignal receptor? Is the battery exhausted?

^

Cooling (Heating)efficiency is notgood.

•Is the setting temperature suitable? •Are air filter dirty?•Is the air inlet or outlet obstructed?

•Is indoor fan speed set at low speed?

•Is there any heat source in your room?

Indoor unit does not operateimmediately when the airconditioner is restarted.

If the air conditioner is turned on immediately after it isturned off, the protective delay switch will delay theoperation for 3 to 5 minutes.

There is unusual smellblowing from the outletafter operation is started.

'

The air conditioner itself does not have undesirableodor. If there is odor, it may be due to accumulationof the odor in the environment. Please clean the airfilter or activate the cleaning function.

There is sound of runningwater during the runningof air conditioner.

*Sometimes the "hissing" sound of running watercan be heard. This is the sound of the flow of therefrigerant, not a malfunction.

A slight "click" sound isheard at the of start-up orshut-down.

Due to temperature changes, panel and other partswill swell, causing the sound of friction. This is normal,

not a fault.

ADuring the cooling operation,the indoor unit outletsometimes will blow out mist.

This is because the indoor air is cooled rapidly. After itruns for some time, the indoor temperature andhumidity will be reduced and the mist will disappear.

Immediately stop all operations and cut off the power supplycontact our Service center locally in following situations.

Shrill sound is heard or Unpleasant odor is emitted during the operation.AThere is an abnormal heat in power supply cord and power plug.

Accidentally pour impurities or water into the machine or the remote control.A Air switch or protection switch often breaks._

- 1 1 -

Page 14: Owner s Manual - Klimaire...Heating will resume after defrost is complete. Notes for turning off When the air conditioner is turned off, the main controller will automatically decide

Notices for installationImportant Notices

Before installing, please contact with local authorizedmaintenance center, if unit is not installed by the authorizedmaintenance center, the malfunction may not solved,due todiscommodious contact.The air conditioner must be installed by professionals accordingto the national wiring rules and this manual.To move and install air conditioner to another place, pleasecontact our local special service center.

Requirements For Installation Position ^•Avoid places of inflammable or explosive gas leakage or wherethere are strongly aggressive gases.•Avoid places subject to strong artificial electric/magnetic fields.•Avoid places subject to noise and resonance.•Avoid severe natural conditions (e.g. heavy lampblack, strongsandy wind, direct sunshine or high temperature heat sources).•Avoid places within the reach of children.•Shorten the connection between the indoor and outdoor units.•Select where it is easy to perform service and repair andwhere the ventilation good.•The outdoor unit shall not be installed in any way that couldoccupy an aisle, stairway, exit, fire escape, catwalk or any otherpublic area.•The outdoor unit shall be installed as far as possible from thedoors and windows of the neighbors as well as the green plants.

Requirements of the mounting structure

•The mounting rack must meet the relevant national or industrialstandards in terms of strength with welding and connectionareas rustproofed.

•The mounting rack and its load carry surface shall be able towithstand 4 times or above the weight of the unit, or 200kg,whichever is heavier.

•The mounting rack of the outdoor unit shall be fastened withexpansion bolt.

•Ensure the secure installation regardless of what type of wallon which it is installed, to prevent potential dropping that couldhurt people.

- 1 2 -

440.9lbs

Page 15: Owner s Manual - Klimaire...Heating will resume after defrost is complete. Notes for turning off When the air conditioner is turned off, the main controller will automatically decide

Notices for installationElectrical Safety Requirements

•Be sure to use the rated voltage and air conditioners dedicatedcircuit for the power supply, and the power cord diameter mustmeet the national requirements.

•When the maximum current of air conditioner is >16A, it must usethe air switch or leakage protection switch equipped withprotection devices.

•The normal operating range is 90%-110% of the local rated voltage•The minimum clearance between the air conditioner and the

combustibles is 1.5 m.

•The Interconnection cord connect the indoor and outdoor units. Youmust first choose the right cable size before preparing it forconnection.

•Cable Types:Outdoor Power Cable: H07RN-F or H05RN-F;Interconnection cord: FI07RN-F or FI05RN-F;

•Minimum Cross-Sectional Area of Power Cable andinterconnection cord

North America Other RegionsApplianceAmps(A) AWG

10 1813 1618 1425 1230 1040 8

Rated Currentof Appliance(A)

Nominal Cross-Sectional Areafmm2)

>3 and < 6 0.75>6 and 10 1>10 and 16 1.5>16 and <25 2.5>25 and <32 4>32 and <40 6

•The size of the interconnection cord, power cable, fuse, andswitch needed is determined by the maximum current of the unitThe maximum current is indicated on the nameplate located onthe side panel of the unit. Refer to this nameplate to choose theright cable, fuse, or switch.

•Note: Core number of cable refer to the detailed wiring diagramadhered on the unit which you purchased.

- 13 -

4.5ft.

0.0001160.0015500.0023250.0038750.0062000.009300

Page 16: Owner s Manual - Klimaire...Heating will resume after defrost is complete. Notes for turning off When the air conditioner is turned off, the main controller will automatically decide

Notices for installationRequirements for operations at raised height

•When carrying out installation at 2m or higher above the baselevel, safety belts must be worn and ropes of sufficient strengthbe securely fasten to the outdoor unit, to prevent falling thatcould cause personal injury or death as well as property loss.

Grounding Requirements

•The air conditioner is the typeIelectrical appliance and mustensure a reliable grounding.

•Do not connect the grounding wire to a gas pipe, water pipe,lightning rod, telephone line, or a circuit poorly grounded tothe earth.

•The grounding wire is specially designed and shall not be usedfor other purpose, nor shall it be fastened with a commontapping screw.

Others

•The connection method of the air conditioner and the power cordand the interconnection method of each independent elementshall be subject to the wiring diagram affixed to the machine.

•The model and rating value of the fuse shall be subject to thesilkscreen on corresponding controller or fuse sleeve.

Packing list

Packing list of the indoor unit Packing list of the outdoor unitName Quantity Unit

Indoor Unit 1 Set

Remote Controller 1 PC

Batteries ( 7#) 2 PC

Instructions 1 Set

Drain pipe 1 PC

Name Quantity Unit

Outdoor Unit 1 Set

Connecting pipe 2 PC

Plastic Strap 1 ROLL

Pipe Protection Ring 1 PC

Luting (putty) 1 PACKET

NOTE: All accessories shall be subject to actual packaging material, and if thereis any difference, please understand.

- 14

6.6ft

Page 17: Owner s Manual - Klimaire...Heating will resume after defrost is complete. Notes for turning off When the air conditioner is turned off, the main controller will automatically decide

Install indoor unitDimension drawing of indoor unit installation

Space to the ceiling

,1 cm

Space to the wall

cm

Space to the wall

< ^^ cm

cm

Space to the floor

Mounting plate

1. The wall for installation of the indoor unit shallbe hard and firm, so as to prevent vibration.

2. Use the "+" type screw fasten the peg board,horizontally mount the peg board on the wall, andensure the lateral horizontal and longitudinal vertical.

3. Pull the peg board by hand after the installation,to confirm whether it is solid.

Wall-through Hole1. Make a hole with an electric hammer or a

water drill at the predetermined position onthe wall for piping, which shall slant outwardlyby °.

2. To protect the piping and the cables frombeing damaged running through the wall,and from the rodents that may inhabit inthe hollow wall, a pipe protecting ring shallbe installed and sealed with putty.

Note: Usually, the wall hole is 60mm~080mm.Avoid pre-buried power wire and hard wallwhen making the hole.

Putty

Pipe protection ring

- 15 -

5.9in above

7.9in above

78.7in above

7.9in above

41°F - 50°F.

Ø 2.36in Ø 3.15in

Page 18: Owner s Manual - Klimaire...Heating will resume after defrost is complete. Notes for turning off When the air conditioner is turned off, the main controller will automatically decide

Install indoor unitz Route of Pipeline

1. Depending on the position of the unit, the piping may be routed sideway from theleft or the right ( Fig 1 ), or vertically from the back( Fig 2 )(depending on the pipelength of the indoor unit). In the case of sideway routing, cut off the outlet cuttingstock of the opposite side.

Fig 1

Connecting PipeDrain Hoseand Cables

Connecting PipeDrain Hoseand Cables

Outlet material preparation Fig 2_

Drain pipe connection1. Remove the mountings and pull the indoor unit pipe out of the housing.2. Connect the connecting pipe to the indoor unit:

Aim at the pipe center, tighten the Taper nut with fingers, and then tighten the Tapernut with a torque wrench, and the directionis shown in diagram on the right. The torque —used is shown in the following table.

~

Tightening torque table Taper nut connecting pipe

The size of pipe( )6/ 6.

Torque(N •m)1 5 — 2 5

9 / 9. 52 3 5-4 012/ 12. 4 5-6 0

7 3-7 87 5-8 0

Indoor unit

Spanner ^Torque wrench

, Wrap the Piping1. Use the insulation sleeve to wrap the joint part

the indoor unit and the connection pipe, and thenuse insulating material to pack and seal insulationpipe, to prevent generation of condensate water onthe joint part.

2. Connect the water outlet with drain pipes, and makethe connection pipe, cables, and the drain hose straight. ^ Plastic strap

3. Use plastic cable ties to wrap the connecting pipes, cablesand drain hose. Run the pipe sloping downward.

Connecting PipeDrain Hoseand Cables

- 16 -

(1/4)(3/8)(1/2)(5/8)(3/4)

inch

11,06 ~ 18,4425,81 ~ 29,5033,19 ~ 44,2553,84 ~ 57,5355,32 ~ 59,00

Torque (lbf *ft)

Page 19: Owner s Manual - Klimaire...Heating will resume after defrost is complete. Notes for turning off When the air conditioner is turned off, the main controller will automatically decide

Install Indoor UnitFixing the Indoor Unit -

1. Hang the indoor unit on the peg board,and move the unit from left to right toensure that the hook is properly positionedin the peg board.

2. Push toward the lower left side and theupper right side of the unit toward the pegboard, until the hook is embedded in theslot and makes a "click" sound.

Wiring diagram

•If your air conditioner is provided with interconnection cord, the wiring of the indoorunit is connected in the factory, there is no need of connection.

•If the interconnection cord is not provided, connection is needed in accordance withthe wiring diagram.

Constant speed Variable speed

| 5 | 4 | I I 2(N | 1(L) |

)

To Outdoor unit

5 | 4 | 3 | | 2 N | 1( ) |

To Outdoor unit

| L | i l Q I |

To Outdoor unit

L | | | | S

To Outdoor unit

Connector

l e (e) e |If there is a connector,connect it directly.

This manual usually includes the wiring mode for the different kind of A/C.We cannot exclude the possibility that some special type of wiring diagramsare not included.The diagram are for reference only. If the entity is difference with this wiringdiagram, please refer to the detailed wiring diagram adhered on the unit whichyou purchased.

- 17 -

Page 20: Owner s Manual - Klimaire...Heating will resume after defrost is complete. Notes for turning off When the air conditioner is turned off, the main controller will automatically decide

Install outdoor unit

Dimension drawing of outdoor unit installation - “

Space to the obstruction

Space to the obstruction

Air out side

Left installation feetAir inlet

Right installation feetA

- 1

Air outletL -

Air in side

Space to the obstruction

Installation outdoor unit boltA B

665(710) 42 280( ) x

( )( 255( 285( ) 545 285

) 55 290( ) 545 315

( 590(690) 310( ) 655 310

70 350795 330

( x 803 395 409

Install the connection pipe

Connect the Outdoor Unit with Connecting Pipe:Aim the counter-bore of the connecting pipe at thestop valve, and tighten the Taper nut with fingers.Then tighten the Taper nut with a torque wrench. Stop valve Taper nut Connecting pipe

When prolonging the piping, extra amount of refrigerantmust be added so that the operation and performanceof the air conditioner will not be compromised.

Piping length Amount of refrigerant to be added5M Not needed

12000Btu 20g/mCC 18000Btu 30g/m

liquid side pipeGas side pipe

Spanner

Note: This table is for reference only.

- 18 -

11.8in Above

7.9i

n A

bo

ve

3.9in Above

11.8in Above

78.9in Above

16.4ft

16.4ft - 49.2ft

25.9(27.7)*16.4*10.923.4(25.2)*18.9*10.125.7(27.7)*19.5*9.427.3*29.1*19.5*9.427.3(29.1)*19.5*9.928.5(30.4)*21.3*11.129.6(31.6)*21.3*11.130.8(32.8)*21.5*11.331.2(33.5)*21.3*12.3

31.2(33.2)*23(26.9)*12.132.2(34.3)*25.5*12.135.1(37.1)*31.0*12.937.8(40.7)*31.3*15.4

16.815.619.517.921.121.121.321.321.121.124.620.926.3

10.911.310.110.110.910.911.712.312.713.113.713.716.0

inch inchinch

0.215oz/ft0.323oz/ft

Page 21: Owner s Manual - Klimaire...Heating will resume after defrost is complete. Notes for turning off When the air conditioner is turned off, the main controller will automatically decide

Install outdoor unitWiring Connection

1.Loosen the screws and remove E-parts cover from the unit.2.Connect the cables respectively to the corresponding terminals

of the terminal board of the outdoor unit (see the wiring diagram),and if there are signals connected to the plug, just conduct butt joint.

3.Ground wire: Remove the grounding screw out of the electricbracket, cover the grounding wire end onto the grounding screwand screw it into the grounding hole.

4.Fix the cable reliably with fasteners (Pressing board).5.Put the E-parts cover back in its original place and fasten

it with screws.

^y | E-parts

_

Wiring diagram

Constant speed

I N | |^ I | 3

To power To Indoor unit

I | I I ( ) | 3 | 4 | 5

To power To Indoor unit

Variable speed

I N | S | |

To Indoor unit To power

S N Lo L

To Indoor unit To power

Connector

If there is a connector,connect it directly.

NOTE:This manual usually includes the wiring mode for the different kind of A/C.We cannot exclude the possibility that some special type of wiring diagramsare not included .The diagram are for reference only. If the entity is difference with this wiringdiagram, please refer to the detailed wiring diagram adhered on the unit whichyou purchased.

- 19 -

Page 22: Owner s Manual - Klimaire...Heating will resume after defrost is complete. Notes for turning off When the air conditioner is turned off, the main controller will automatically decide

Install outdoor unitExpelling the air

Outdoor unit refrigerant discharging methodAfter the pipe side connection is complete, proceed as follows.

Gas part =

Liquid part

Loosen thetemporarily fastenednut by half turn.

Loosen the Hexwrench by half turn

Quickly tighten andconnect the nut.

The installing torqiis the same asof the gas end ofthe indoor unit.

ueat Fully open the

spindles of theliquid end and ofthe other two ends.

Check that all indoorand outdoorconnections are freeof air leakage.

Compound meter-76cmHg )

Handle Lo

Pressure gauge

^ manifold valveHandle Hi

Vacuum Pumping Method (R410A refrigerant evacuation must use the vacuumpumping method)

Before working on the air conditioner, remove the cover of the stop valve(gas andliquid valves)and be sure to retighten it afterward.( prevent the potential air leakage)1. To prevent air leakage and spilling tighten

all connecting nut of all flare tubes.2. Connect the stop valve, charge hose, manifold

valve, and vacuum pump.3. Fully open the handle Lo of the manifold valve

and apply vacuum for at least 15 minutes andcheck that the compound vacuum gauge reads-0.1MPa(-76cmHg).

4. After applying vacuum, fully open the stopvalve with a hex wrench.

5. Check that both indoor and outdoorconnections are free of air leakage. stop va|ve stop vg|ve

uid valve) (gas valve)

Vacuum pump

(liq

Outdoor condensation drainage(Heat pump type only)

When the unit is heating, the condensing water and defrostingwater can be out reliably through the drain house.InstallationInstall the outdoor drain elbow in 025 hole on the baseplate, and joint the drain hose to the elbow, so that thewaste water formed in the outdoor unit can be drainedout a proper plate. Outdoor drain elbow

- 20 -

Page 23: Owner s Manual - Klimaire...Heating will resume after defrost is complete. Notes for turning off When the air conditioner is turned off, the main controller will automatically decide

Check after installation and test operationCheck after installation

Electrical Safety Check1. If the supply voltage is as required.2. If there is any faulty or miss connection in each of the power, signal and

grounding wires.3. If the grounding wire of the air conditioner is securely grounded.

Installation Safety Check1. If the installation is secure.2. If the water drain is smooth.3. If the wiring and piping are correctly installed.4. Check that no foreign matter or tools are left inside the unit.

Leak test of the refrigerantDepending on the installation method, the following methods may be used checkfor suspect leak, on areas such as the four connections of the outdoor unit and thecores of the cut-off valves and t-valves:1.Bubble method: Apply of spray a uniform layer of soap water over the suspected

leak spot and observe carefully for bubble.2.Instrument method: Checking for leak by pointing the probe of the leak detector

according to the instruction to the suspect points of leak.

Test OperationTest Operation preparation:

^Verify that all piping and connection cables are well connected.

^Confirm that the values at the gas side the liquid-side are fully open.

^Connect the power cord to an independent power socket.

^Install batteries in remote control.Test Operation method:1. Turn on the power and push the ON OFF switch button of the remote controller to

start the air conditioner.2. Select COOL, HEAT (not available on cool-only models) , SWING and other

operation modes with the remote controller and see if the operation is ok.

Specific caution

I.Open front panel of the indoor.2.The connector(as Fig) can not touch the terminal

board, and is positioned as shown in Fig.

—Connector

CablelCable2Terminal board

- 2 1 -